3582 Springwood Path - Site SurveyALE : 1 INCH = 30 FEET
110162.003 3D PJB
REVISED:
11/12/10
NOTE:
STAKE
nl
NOTE:
NOTE:
NOTE:
NOTE:
NOTE:
NOTE:
NOTE:
S
3498
LOT AREA = 13,692 SF.
HOUSE AREA =1,775 SF.
SIDEWALK AREA =42 SF.
PORCH AREA =167 SF.
DRIVEWAY AREA =898 SF.
COVERAGE =21.0%
BUILDING COVERAGE =
COVERAGE =13.0%
Certificate of Survey for: LENNAR HOMES
ADDRESS: 3582 SPRINGWOOD PATH, EAGAN, MN
BUYER: RUIZ MODEL: SINCLAIR ELEVATION: E
iivcrpk" , F"_`?'
41 is
V
z
BENCH MARK:
TOP OF SPIKE
ELEV.= 905.55 N .
engineerin
CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS
2422 Enterprise Drive, Mendota Heights, MN 55120, Phone: (651) 681 1914 Fax: (651) 681 9488 - Pioneereng.com
LO
0
cn
✓
• .VIEWED
By
DL. /z /22
EAGAN t:niGINEERtNG DE'1'.
0
✓
1 o 34. (
1 5.6'1 - lP 1
r 905.0 0
0 }1 gE� �n5P \KE °A 908.2
0 .,i0P O
907.6 - ELE • -
_ "E
(906. .....
36.5°
ADD BRICK LEDGE AS REQUIRED
GRADING PLAN BY PIONEER ENGINEERING LAST DATED 5/2.8/10 WAS USED
TO DIIERMINE THE PROPOSED ELEVATIONS SHOWN ON THIS CERTIFICATE.
PROPOSED BUILDING DIMENSIONS SHOWN ARE FOR HORIZONTAL
LOCATION OF STRUCTURES ON THE LOT ONLY. CONTACT (WILDER
PRIOR TO CONSTRUCTION FOR APPROVED CONSTRUCTION PLANS.
NO SPECIFIC SOILS INVESTIGATION HAS BEEN PERFORMED ON THIS LOT
BY THE SURVEYOR. THE SUITABILITY OF SOILS TO SUPPORT THE SPECIFIC
HOUSE PROPOSED IS NOT THE RESPONSIBILITY OF THE SURVEYOR.
THIS CERTIFICATE DOES NOT PURPORT TO SHOW EASEMENTS OTHER
THAN THOSE SHOWN ON THE RECORDED PLAT.
CONTRACTOR MUST VERIFY DRIVEWAY DESIGN.
BEARINGS SHOWN ARE BASED ON AN ASSUMED DATUM
VACANT
3:1 Maximum Slopes
or R' taining Wall Will
Ba =tt quired
902. »
902.
i 9 02.9' 48
>
D oc
... ..R C ^,,,_ `n.. y y- ,uaca...., 1M1131%• rmo.mr •7 iZAIRSITai6i1 ,G:u - . r_"•
0
0
(g 037)
13
a 0
902.
EAGAN
REVIEWED
BUILDING INSPE:.,.
WE HEREBY CERTIFY TO LENNAR HOMES THAT THIS IS A TRUE AND CORRECT REPRESENTATION OF A
SURVEY OF THE BOUNDARIES OF:
LOT 8, BLOCK 2, STONEHAVEN 1ST ADDITION
DAKOTA COUNTY, MINNESOTA
IT DOES NOT PURPORT TO SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN, AS SURVEYED BY
UNDER MY DIRECT SUPERVISION THIS 4TH DAY OF NOVEMBER, 2010
1 000.0 1
j' 899 INSTALL
PERIMETER. CONTROL
ME OR
901.6
0
O
co
IViSiONHOUSE ELEVATIONS
LOWEST FLOOR ELEVATION
TOP OF FOUNDATION ELEV.
0 0
•
PROVIDE AND MAINTAIN
INLET PROTECTION UNTIL
FINAL TURF IS ESTABLISHED
LOWEST ALLOWABLE FLOOR ELEV. :900.1
:(PROPOSED) /ASBUILT
(900.1)
(908.1)
GARAGE SLAB ELEV. @ DOOR : (907.7)
X 000.00
( 000.00 )
DENOTES SPIKE
DENOTES PROPOSED SILT FENCE
DENOTES EXISTING ELEVATION
DENOTES PROPOSED ELEVATION
DENOTES DRAINAGE FLOW DIRECTION
DENOTES PROPOSED ROCK CONSTRUCTION
DENOTES EMERGENCY OVERFLOW
DENOTES ELEVATION ON
DRIVEWAY
SIGNED: e NEER1 ENGINEERING, P.A.
BY: / µ � +' " ,.... .
Peter J. Howkinson License No. 42299