Loading...
2700 Blue Water Rd - Ltr. re: Mezzanine Guardrail WorkFebruary 4, 201 Mike Lence Building Inspector City of Eagan 3830 Pilot Knob Road Eagan, MN 55122 F F l )i'111 If further information is required, please contact our office. Sincerely, Krenik, Senior Associate, Tushie Montgomery Architects Licensed Architect: #22920 Cc: Tom Miller -NAC Mark Gaetz - Mulcahy T U S H I E MONTGOMERY ARCHITECTS Project: Mulcahy Expansio 1100 Grand Oaks Business Center I 2700 Blue Water Drive Eagan, Minnesota 55121 RE: Openings in guard railings Dear Mr. Lenz, This letter; is being written as a matter of record for the mezzanine guardrail work being performed at Suite 100 for the Mulcahy Expansion project. According to Exception #3 of IBC Section 1013.3, in areas not open to the public, within this occupancy of S-1, openings between balusters, horizontal intermediate rails or other components of the guard rail system shall be constructed such that a sphere with a diameter of 21 inches shall not pass through any opening. The tenant involved has stated that their warehouse employees will be the only personnel accessing the storage mezzanine area. Therefore, the reference on the submitted building permit documents that refers to guardrail with "balusters at 4" on center" shall be understood by all parties as deleted and superseded with the requirement as follows: "42" high guardrail with balusters and horizontal components such that no sphere of 21" may pass through ". Guardrails shale l be constructed at all sides which are open to below. 7645 Lyndale Avenue South, # 100 Minneapolis , Minnesota 55423 612 . 861 . 9636 Fax: 612 . 861 . 9632 www.tmiarchitects.com