3583 Lemieux Cir - Energy Calcsj2 Rv;TX4 New Construction Energy Code Compliance Certificate RECEIVED FEB 15 2011 Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. Mailing Address of the Dwelling or Dwelling Unit 3583 LEMIEUX CIRCLE Name of Residential Contractor RON CLARK CONSTRUCTION THERMAL ENVELOPE Insulation Location Bela�ct� Eirttire:Sleb ><:::::: Foundation Wall ET'�of�SISt1R::fitlC�.�s".7 ............................. Ceiling, flat' :: Rim Joist (Foundation) Rtm Joist (1 •FloorF) Wan .Ceiling, vaulted Bay windows ur cantileve, e areas Bonus room over garage .............................. ............................... Describe other: insstilated 5 10 1 0: 19 4 44 40 Type: Check All That Apply X City EAGAN MN License Number 1221 X Date. Certificate Posted . ........................_..____ rye i locati interior :: Ron Clark Construction & Design RADON SYSTEM Passive (No Fan) Other Please Describe Here Type in location: exterior Type in location: interior ...................... ...................... R:3O Batts with Windows & Doors Average U- Factor (excludes skylights and one door) U: Solar Heat Gain Coefficient (SHGC): *arm ©.3/ Vllfres O• Heating or Cooling Ducts Outside Conditioned Spaces X Not applicable, all ducts located in conditioned space R -value MECHANICAL SYSTEMS j Appliances Fuel Type. Manufacturer Rating or Size Structure's Calculated- Efficiency Heating System BRYANT 0AAV03C080: Input in BTUS: Heat:i;oss.: AFUE or HSPF% 80,000 92% Domestic Water Heater ELECTR Marathon MR 052:45 Capacity in G. Ions: 105 Cooling System ELECTRIC: BRYANT 13ANA03. Output in Tons: S Calculated cooling load: gTT' 13 Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two fitmaces or air source heat pump with gas back -up fumace): Select Type X Heat Recover Ventilator (HRV) Capacity in cfins: Energy Recover Ventilator (ERV) Capacity in cfirs: Continuous exhausting fan(s) rated capacity in cfins: Low: Low: Location of fan(s), describe: I Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms 117 High: High: 185 Make - Air Select a Type X . Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Other, describe: Location of duct or system: Basement Cfin's " round duct OR "metal duct Combustion Air Select a Type X Not required per mech. code Passive 6" Other, describe: Location of duct or system: Basement Cfin's " round duct OR " metal duct Created by BAM version 052009 fzitvisG,O - 3583 Lemieux Circle HVAC Load Calculations for Ron Clark RiaiNIAC REB IDE�N'i'IAL HVAC Lo Ave Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Prepared By Alan Dobson Burnsville Heating & A/C Inc. 3451w Burnsville Pkwy, Suite 120 Bumsville,MN 55337 952 - 894 -0005 Monday, February 14, 2011 Total Building Supply CFM: Square ft. of Room Area: Volume (ft of Cond. Space: Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Notes 1,162 3,274 29,459 54,777 Btuh 24,813 Btuh 2,764 Btuh 27,577 Btuh CFM Per Square ft.: Square ft. Per Ton: Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 0.355 1,425 54.777 MBH 90 °%o 10 % 2.30 Tons (Based On Sensible + Latent) C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14,2011, 11:07. AM Rhvec1= Residential & Light Commercial HVAC Loatls Burnsville Heating & A /C Inc - �N- X55337 - Elite Software Development, Inc 3583 Lemieux Circle . =- P-aje '21 _Bumsvife,M = Project Report Genera? ®ect information ate - '_x , -� x Project Title: 3583 Lemieux Circle Designed By: . Alan Dobson Project Date: Monday, February 14, 2011 Project Comment: Client Name: Ron Clark Company Name: Burnsville Heating & A/C Inc. Company Representative: Alan Dobson Company Address: 3451w Burnsville Pkwy, Suite 120 Company City: Bumsville,MN 55337 Company Phone: 952- 894 -0005 Company Fax: 952- 894 -0925 Company Comment: Des • neDaCa ,� k n.�.; a, ''' ' rt�������� � �� �' � �-`. x� '� �.. ��� �,, .... Reference City: Minneapolis, Minnesota Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor. 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Dry Bulb Wet Bulb ReLHum Rel.Hum Indoor Dry Bulb Grains Difference . Winter. -15 -15.33 80% n/a Summer: 88 73 50% 50% 72 75 n/a 35 Total Building Supply CFM: Square ft. of Room Area: Volume (ft of Cond. Space: Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Notes 1,162 3,274 29,459 54,777 Btuh 24,813 Btuh 2,764 Btuh 27,577 Btuh CFM Per Square ft.: Square ft. Per Ton: Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 0.355 1,425 54.777 MBH 90 °%o 10 % 2.30 Tons (Based On Sensible + Latent) C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14,2011, 11:07. AM Rhvac Residential & Light-Commercial HVAC Loa 8umsvdle Heating & 'A!' Burnsville; MN. 55337 - Miscellaneous Report Winter. Summer: r D Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Ot tside:AitData Infiltration Specified: Infiltration Actual: Above Grade Volume: Duct Load ct oScenai> fob S efi et. ', Dffeerence; -15 -15.33 80% n/a 72 n/a 88 73 50% 50% 75 35.17 Main Trunk Runouts Yes Yes No No 0.00300 0.01000 0.1000 in.wg. /100 ft. 0.1000 in.wg./100 ft. 650 ft. /min. 450 ft. /min 900 ft. /min 750 ft. /min 0 in. 0 in. 0 in. 0 in. q A Winter Summer 0.320 AC/hr 0.170 AC/hr 125 CFM 66 CFM 0.320 AC/hr X 23.457 Cu.ft. 7,506 Cu.ft./hr X 0.0167 125 CFM 0 CFM 0.170 AC/hr X 23.457 Cu.ft. 3,988 Cu.ft. /hr X 0.0167 66 CFM 0 CFM Total Building Infiltration: Total Building Ventilation: - -- System 1 -- Infiltration & Ventilation Sensible Gain Multiplier 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.20 = (0.68 X 0.970 X 35.17 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr (125 CFM), Construction: Average Summer Infiltration Specified: 0.170 AC/hr (66 CFM), Construction: Average 1 Supply Main Attic 16B 0.12 1 Return Main Attic 16B 0.24 150 56 No No C: \Elite \Rhvac 8\Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM rte Software Development Inc. j .} 3583 Lemieux Circle 4Page 10. Rhvan - Residential & Light Commercial HVAC Loa Bumsvilie Heating & NC Inc Burnsville, MN 55337 Total Building Summary Loads __ Gim Cr RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 170 4,585 0 5,705 5,705 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 25.2 659 0 274 274 SHGC 0.37 1 A -rv-d: Glazing - Single pane, sliding glass door, 40.8 1,171 0 446 446 reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 RC: Glazing -RC, u -value 0.3, SHGC 0.37 60 1,566 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 Front Door Door - Brandl Front Door 20.4 248 0 69 door: Door- 19 282 0 78 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 1605.9 9,501 0 1,026 cavity, no board insulation, brick finish, wood studs R -5 wall: Wall- Basement, , R -5 board with poured wall 1077.5 10,557 0 820 820 16CR- 44 -ad: Roof /Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R-44 insulation, dark asphalt 20P -10-c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 Passive, R -10 board insulation, carpet covering 19A -30p: Floor-Over enclosed unconditioned crawl 130.4 324 0 48 48 space, No insulation on exposed walls, sealed or vented space, passive, R -30 blanket 21 A -32 -v: Floor - Basement, Concrete slab, any thickness, 1543 2,685 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 32' wide Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 125, Summer CFM: 66 Ventilation: Winter CFM: 0, Summer CFM: 0 AED Excursion: Total Building Load Totals: kF"+ tn�S Total Building Supply CFM: Square ft. of Room Area: Volume (ft of Cond. Space: Total Heating Required Including Ventilation Air Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air. C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv 1,162 3,274 29,459 54,777 Btuh 24,813 Btuh 2,764 Btuh 27,577 Btuh 2 0 38,413 CFM Per Square ft.: Square ft. Per Ton: 4,750 361 11,614 1,543 0 0 0 0 KA, Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. 2,310 1,591 0 113 113 0 15,197 15,197 460 600 1,060 400 1,200 1,600 0 0 2,170 2,531 923 2,466 0 0 4,723 4,723 54,777 2,764 24,813 27,577 0.355 1,425 2,310 1,591 1,155 69 78 1,026 `BuiiIdi ® loads r 54.777 MBH 90 10 % 2.30 Tons (Based On Sensible + Latent) Monday, February 14, 2011, 11:07 AM C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Development inc =1 3583 Lemieux Circle. Page 13 I i Rhva Residen & Light Commercial HVAC Loads i Bumsville Heating8 Inc - , Bur eAlle MN 55337 y _ . _ _ " Elite Software = System 1 Main Floor Summary Loads I Component Area Sen -y La Descn'tion z< < Ouan �k _Loss es Galn 4 _. 5erk � fiot# Gain yGain RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 170 4,585 0 5,705 5,705 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 25.2 659 0 274 274 SHGC 0.37 1 A -ry -d: Glazing - Single pane, sliding glass door, 40.8 1,171 0 reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 446 446 RC: Glazing -RC, u-value 0.3, SHGC 0.37 60 1,566 0 2,310 2,310 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 0 1,591 1,591 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 0 113 113 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 1,155 Front Door: Door - Brandl Front Door 20.4 248 0 69 69 door: Door- 19 282 0 78 78 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 1605.9 9,501 0 cavity, no board insulation, brick finish, wood studs 1,026 1 ,026 R -5 wall: Wall- Basement, , R -5 board with poured wall 1077.5 10,557 0 820 820 1 16CR- 44 -ad: Roof /Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R -44 insulation, dark asphalt 20P -10 -c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 Passive, R -10 board insulation, carpet covering 19A -30p: Floor -Over enclosed unconditioned crawl 130.4 324 0 space, No insulation on exposed walls, sealed or I vented space, passive, R -30 blanket 48 48 21 A -32 -v: Floor- Basement, Concrete slab, any thickness, 1543 2,685 0 0 0 2 or more feet below grade, no insulation below floor, vinyl cover shortest side of floor slab is 32' w ide Subtotals for structure: - 38,413 0 15,197 15,197 People: 2 460 600 1,060 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 4,750 361 2,170 2,531 Infiltration: Winter CFM: 125, Summer CFM: 66 11,614 1,543 923 2,466 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 4,723 4,723 System 1 Main Floor Load Totals: 54,777 2,764 24,813 27,577 -Check. es ,_ .�, M v r -1 N ` , "` � - 1 .: Supply CFM: 1,162 CFM Per Square ft.: 0.355 Square ft. of Room Area: 3,274 Square ft. Per Ton: 1,425 Volume (ft of Cond. Space: 29,459 ::.x r sterrt ads f ` t , _ _ Total Heating Required Including Ventilation Air: 54,777 Btuh 54.777 MBH Total Sensible Gain: 24,813 Btuh 90 % Total Latent Gain: 2,764 Btuh 10 % Total Cooling Required Including Ventilation Air: 27,577 Btuh 2.30 Tons (Based On Sensible + Latent) c - Vie` Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM C:\Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM t Rhvac,7 Residential & Light Commercial HVAC Loads Burnsviffe Heating & A/C Inc _ Burnsville; MN 55337 - Load _ Elite Software Development, Inc. 3583 Lemieux Circle _ =: Pade System 1, Zone 1 Summary Loads (Peak Proced for Roo Component �� 4 - � Sen Total DescriDt on t t c � : ua Loss aG arn Ga in RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 115.8 3,123 0 3,605 3,605 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 19.2 502 0 209 209 SHGC 0.37 1 A -ry -d: Glazing - Single pane, sliding glass door, 40.8 1,171 0 446 446 reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 RC: Glazing -RC, u -value 0.3, SHGC 0.37 60 1,566 0 2,310 2,310 Front Door: Door - Brandl Front Door 20.4 248 0 69 69 door: Door- 19 282 0 78 78 12E -Obw: Wail- Frame, R -19 insulation in 2 x 6 stud 1406.9 8,324 0 899 899 cavity, no board insulation, brick finish, wood studs 16CR- 44 -ad: Roof /Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R -44 insulation, dark asphalt 20P -10 -c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 , Passive, R -10 board insulation, carpet covering 19A -30p: Floor -Over enclosed unconditioned crawl 130.4 324 0 48 48 space, No insulation on exposed walls, sealed or vented space, passive, R -30 blanket Subtotals for structure: 20,118 0 12,457 12,457 People: 2 460 600 1,060 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 2,656 0 1,346 1,346 1 Infiltration: Winter CFM: 85, Summer CFM: 45 7,851 1,043 624 1,667 System 1, Zone 1 Load Totals: 30,625 1,903 19,156 21,059 Check Figures Supply CFM: 897 CFM Per Square ft.: 0.518 Square ft. of Room Area: 1,731 Square ft. Per Ton: 986 Volume (ft of Cond. Space: 15,572 Zone Loads Total Heating Required: 30,625 Btuh 30.625 MBH Total Sensible Gain: 19,156 Btuh 91 % Total Latent Gain: 1,903 Btuh 9 % Total Cooling Required: 21,059 Btuh 1.75 Tons (Based On Sensible + Latent) Notes �. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac Residential& Light Commercial HVAC Loads Eitte Software Development, Inc. BurnsvNle Heating &;A/C Inc 3 583 Lemieux` Circle. Bumsville.: MN. 55337 Page 18 RC: Glazing -RC,- ground reflectance = 0.23, u -value 0.31, 54.2 1,462 0 2,100 2,100 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 0 1,591 1,591 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u-value 0.3, 6 157 0 65 65 SHGC 0.37 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 0 113 113 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 1,155 R -5 wall: Wall - Basement, , R -5 board with poured wall 1077.5 10,557 0 820 820 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 199 1,177 0 127 127 cavity, no board insulation, brick finish, wood studs 21 A -32 -v: Floor- Basement, Concrete slab, any thickness, 1543 2,685 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 32' wide Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 41, Summer CFM: 22 System 1, Zone 2 Load Totals: '0:13 urei. ' Supply CFM: Square ft. of Room Area: Volume (ft of Cond, Space: Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: 1 Notes C:Elite\Rhvac 8\Ron Clark Briarwood Right.rhv 24,152 Btuh 11 ,730 Btuh 500 Btuh 12,230 Btuh 0 0 550 CFM Per Square ft.: 1,543 Square ft. Per Ton: 13,887 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. 18,295 0 8,813 8,813 0 0 0 0 0 0 0 0 2,094 0 824 824 3,763 500 299 799 24,152 500 11,730 12,230 } 0.356 1,514 24.152 MBH 96 % 4 % 1.02 Tons (Based On Sensible + Latent) Monday, February 14, 2011, 11:07 AM Item Detailed Room Loads - Room 1 - Foyer (Peak Fenestration Gain Procedure G eneraf rte_ Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: E - WaIl- 12E -0bw 5 X 9 E - Door -Front Door 3 X 6.8 E - CeiI- 16CR -44 10 X 5 Subtotals for Structure: Infil.: Win.: 2.3, Sum.: 1.2 Ductwork: AED Excursion: Room Totals: Htg. & clg. 10.0 5.0 50.0 9.0 450.0 1 9 2 398 398 0.479 24.6 20.4 50 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft./min. in.wg./100 ft. 45 0.068 0.140 0.022 Occurrences: System Number. Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 146 248 96 490 4.667 210 66 5.9 12.2 1.9 766 0.6 3.4 0.8 1 1 1 9 CFM 1.2 AC /hr 0 CFM 0 CFM 0 0 CFM 0%a 2 CFM 1 CFM 0 0 0 0 0.378 28 16 69 42 127 17 13 28 28 185 C: \Elite\Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac - Residential & Light Commercial HVAC Loads Burnsville Heating t A/C Inc Bumsvil INN =55337 Detailed Room Loads - Room 2 - Den (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Subtotals for Structure: Infil.: Win.: 9.4, Sum.: 5.0 Ductwork: AED Excursion: Room Totals: Htg. & clg. 15.6 11.2 175.0 9.0 1,572.0 1 33 5 244 244 0.049 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. u .Quart E - Wall- 12E -Obw 11.2 X 9 100.8 0.068 S - Wall- 12E -Obw 4.2 X 9 37.8 0.068 N - Wall- 12E -Obw 5.4 X 9 31.1 0.068 N - GIs -RC shgc -0.32 99 %S 17.5 0.310 UP- Ceil -16CR- 4415.6 X 11.2 174.7 0.022 187 Occurrences: System Number. Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: l Coss 5.9 596 5.9 224 5.9 184 27.0 472 1.9 334 1,810 4.669 874 255 2,939 0.6 0.6 0.6 13.1 0.8 0.369 1 1 1 33 CFM 1.3 AC/hr 0 CFM 0 CFM 0 0 CFM 0 % 9 CFM 5 CFM 0 0 0 0 0 116 64 24 20 229 146 483 69 50 109 116 711 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Software, Development Inc: 3683 Lemieux Circle ' P ==e25 Rhvac Residen & Light Commercial HVAC Loa B Healin &.NC Inc � .Burnsvilla MN 55337 .: Detailed Room Loads - Room 3 - Kitchen (Peak Fenestration Gain Procedure) Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Room Length: 14.0 Room Width: 20.0 Area: 280.0 Ceiling Height: 9.0 Volume: 2,520.0 Number of Registers: 1 Runout Air: 100 Runout Duct Size: 7 Runout Air Velocity: 375 Runout Air Velocity: 375 Actual Loss: 0.071 ft. ft. sq.ft. ft. cu.ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Subtotals for Structure: Infii.: Win.: 6.3, Sum.: 3.4 Ductwork: AED Excursion: Equipment: Room Totals: CFM Percent of Supply.: in. Actual Summer Vent.: ft /min. Percent of Supply: ft. /min. Actual Winter [nth.: in.wgJ100 ft. Actual Summer Infil.: 1 1 1 100 CFM 2.4 AC /hr 0 CFM 0 CFM 0 To 0 CFM 0 6 CFM 3 CFM t e m � , : - '. - -� Areia' �' -* � ', _ s L Desc rlDtion - _Quantl+ >� .i\atu a . __, i __ Loss L=i'M _ __.. Gala ;Ga 1 N - Wall- 12E -Obw 14 X 9 118.8 0.068 5.9 703 m 0.6 0 76 N - GIs-RC shgc -0.37 0 %S 7.2 0.300 26.1 188 14.4 0 104 I UP-Ceil-16CR-44 14 X 20 280 0.022 1.9 536 0.8 0 234 j 1,427 0 414 126 4.667 588 0.373 78 47 191 150 327 0 1,200 2,206 78 2,138 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Room Totals: 387 198 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM I Rhvac Residential & Light Commercial HVAC Loads = Elite Software Development, Inc.: Bumavile Heating &`AIC Inc ' ' ' temieilix 'Circle! Burnsville; MN 55337 = - 121 Detailed Room Loads - Room 4 - Dining (Peak Fenestration Gain Procedure Room is in zone Calculation Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air. Runout Duct Runout Air Velocity: Runout Air Velocity: Actual Loss: t Item Oesc •t UP- Ceil- 16CR 1, which peaks at 5 pm Mode: Htg. & clg. Occurrences: 1 15.0 ft. System Number: 1 12.3 ft. Zone Number: 1 185.0 sq.ft. Supply Air: 9 CFM 9.0 ft. Supply Air Changes: 0.3 AC/hr 1,661.0 cu.ft. Req. Vent. CIg: 0 CFM 1 Actual Winter Vent.: 0 CFM 9 CFM Percent of Supply.: 0 % Size: 2 in. Actual Summer Vent.: 0 CFM 426 ft./min. Percent of Supply: 0 % 426 ft./min. Actual Winter Infil.: 0 CFM 0.546 in.wg. /100 ft. Actual Summer Infil.: 0 CFM L $ -44 15 X 12.3 184.5 0.022 1.9 353 0.8 0 154 Subtotals for Structure: 353 0 154 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 34 14 AED Excursion: 30 Room Totals: 387 198 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM [ R c Residential & Light Commercial HVAC Loa B Heating & WC Inc Burnsville, ±MN 55337 � . Detailed Room Loads - Room 5 - Sunroom {Peak Fenestration Gain Procedure ' EGO j Room is in zone 1, which peaks at 5 pm 1 Htg. & clg. Occurrences: 14.6 ft. System Number: 1 12.3 ft. Zone Number: 1 180.0 sq.ft. Supply Air: 247 CFM 9.0 ft. Supply Air Changes: 9.2 AC /hr 1,616.0 cu.ft. Req. Vent. Clg: 0 CFM 2 Actual Winter Vent.: 0 CFM 124 CFM Percent of Supply.: 0 % 7 in. Actual Summer Vent.: 0 CFM 463 ft. /min. Percent of Supply: 0 % 463 ft. /min. Actual Winter Infil.: 12 CFM 0.108 in.wg. /100 ft. Actual Summer lnfil.: 6 CFM Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: A uan M <- W - Wall- 12E -Obw 12.3 X 9 61.5 0.068 5.9 364 0.6 0 39 N - Wall- 12E -Obw 14.6 X 9 90.6 0.068 5.9 536 0.6 0 58 W - GIs -RC shgc -0.35 0 %S (2) 19.2 0.310 27.0 518 60.7 0 1,166 N - GIs- 1A -rv-d shgc -0.35 0 %S 40.8 0.330 28.7 1,171 14.2 0 580 W - GIs -RC shgc -0.37 0 %S 30 0.300 26.1 783 61.8 0 1,853 UP- CeiI- 16CR -44 14.6 X 12.3 179.6 0.022 1.9 344 0.8 0 150 Floor- 20P -10 12.3 X 14.6 179.6 0.081 7.0 1,266 0.6 0 116 Floor- 19A -30p 12.3 X 10.6 130.4 0.034 2.5 324 0.4 _ 0 _ 48 5,306 0 4,010 242 4.667 1,130 0.372 150 90 611 371 807 Subtotals for Structure: I nfil.: Win.: 12.2, Sum.: 6.5 Ductwork: AED Excursion: Room Totals: Cite Software Development, Inc. 3583 Lemieux Cycle P-aAe.27° 7,047 150 5,278 C: \Elite \Rhvac 8\Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Detailed Room Loads - Room 6 Procedure) Ge . Room is in zone 1, which peaks Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: W - Wall- 12E -0bw 12.6 X 9 S - Wall- 12E -Obw 14.4 X 9 W - GIs -RC shgc -0.35 0 %S (2) UP- Ceil- 16CR -44 14.4 X 12.6 Subtotals for Structure: Infil.: Win.: 12.2, Sum.: 6.5 Ductwork: AED Excursion: People: 230 lat/per, 300 sen/per: Room Totals: 2a_r at 5 pm Htg. & clg. 14.4 ft. 12.6 ft. 181.0 sq.ft. 9.0 ft. 1,633.0 cu.ft. 1 187 CFM 8 in. 536 ft. /min. 536 ft. /min. 0.120 in.wg. /100 ft. 78.4 129.6 35 181.4 243 2 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual. Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 0.068 5.9 0.068 5.9 0.310 27.0 0.022 1.9 464 767 944 347 2,522 4.667 1,134 347 4,003 Cite Software Development, Inc. 35 83 Lemie Circle - Page.28' Master Bedroom (Peak Fenestration Gain AM WSPERE ENg 1 1 1 187 CFM 6.9 AC /hr 0 CFM 0 CFM 0 % 0 CFM 0 12 CFM 6 CFM 0.6 0 50 0.6 0 83 60.7 0 2,126 0.8 0 152 - - - -- 0 - - - 2,411 0.370 151 90 281 610 460 600 611 3,992 C:\Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac - Residential & Light Commercial HVAC Loads: Burnsville Heating & NC Irk r = . - , - Bumsville, MN. 55337 Detailed Room Loads - Room 7 - Master Bath LPeak Fenestration Gain Procedure) Room is in zone 1, which peaks Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: S - Wall- 12E -Obw 20 X 9 1 UP- CeiI- 16CR -44 20 X 12.6 Subtotals for Structure: Infil.: Win.: 9.1, Sum.: 4.8 Ductwork: AED Excursion: Room Totals: • pOe ft at 5 pm Htg. & clg. 20.0 12.6 252.0 9.0 2,268.0 1 24 3 483 483 0.387 C: \Elite\Rhvac 8 \Ron Clark Briarwood Right.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. 180 0.068 252 0.022 180 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. CIg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 5.9 1,065 0.6 0 115 1.9 482 0.8 0 211 1,547 4.667 840 227 2,614 1 1 24 CFM 0.6 AC /hr 0 CFM 0 CFM 0 0 CFM 0 % 9 CFM 5 CFM 0 326 0.372 112 67 36 77 112 506 Monday, February 14, 2011, 11:07 AM Room Totals: 1,165 450 221 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Bumsvrlle.Heating & A/C Inc `_. 3583 Lemieux Circle- BumsviHe. MN 55337 _ = Page 30 J - Detailed Room Loads Room 8 - Laundry (Peak Fenestration Gain Procedure) r:Generat- 3 x-�-r ,5�. Y. � _ '� �`£ d am : 3 ; t. .�'-'##°4.x _.::.. r --_.N .. `- A,- .... <.F _ Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 9.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 108.0 sq.ft. Supply Air: 10 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 0.6 AC/hr Volume: 972.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent: 0 CFM Runout Air: 10 CFM Percent of Supply.: 0 % Runout Duct Size: 2 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 475 ft. /min. Percent of Supply: 0 % Runout Air Velocity: 475 ft. /min. Actual Winter Infil.: 4 CFM Actual Loss: 0.679 in.wg. /100 ft. Actual Summer Infil.: 2 CFM It m �►rea ; Ht9 Descriptio an a t - C1g v� n -4 Qutrkj ;1/lue... . HTM : Los 31 At . _ k 7t=a Garn. �.. ` rGa1n S- WalI- 12E -Obw 9 X 9 81 0.068 5.9 479 0.6 0 52 UP- Ce11- 16CR -44 9 X 12 108 0.022 1.9 207 0.8 0 90 Subtotals for Structure: 686 0 142 Infil.: Win.: 4.1, Sum.: 2.2 81 4.667 378 0.370 50 30 Ductwork: 101 16 AED Excursion: 34 Equipment: 400 0 Room Totals: 1,165 450 221 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac Residential & Lightcommerciat Burnsville Heating NC Inc'' - - Softwore Development, Ittc:; Bu MN 55337 Pa e 31 Detailed Room Loads -Room 9 - Back EntryTeak Fenestration Gaircedure Room is in zone 1, which peaks at 5 pm 1 Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity Actual Loss: escn tio S -WaIl-12E-Obw 8 X 9 E -Wall-12E-Obw 10 X 9 E -Door-door 2.8 X 6.8 UP-CeiI-16CR-44 8 X 10 Htg. & clg. 8.0 ft. 10.0 ft. 80.0 sq.ft. 9.0 ft. 720.0 cu.ft. 1 18 3 364 364 0.222 CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Cg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 18 CFM 1.5 AC/hr 0 CFM 0 CFM 0% 0 CFM 0% 8 CFM 4 CFM Subtotals for Structure: Infil.: Win.: 8.1, Sum.: 4.3 Ductwork: AED Excursion: Room Totals: C:\Elite\Rhvac 8\Ron Clark Briarwood Right.rhv an 72 0.068 71 0.068 19 0.170 80 0.022 5.9 426 0.6 0 5.9 420 0.6 0 14.8 282 4.1 0 1.9 153 0.8 0 1,281 0 162 4.667 756 0.370 100 193 2,230 100 381 236 60 27 58 Monday, February 14, 2011, 11:07 AM Rhvac Residential & Light Commercial HVAC Loads Bumsvllle Heating & A/C Inc Burnsville. MN 55337 Detailed Room Loads Room 10 - Powder (Peak Fenestration Gain Procedure) General Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: • Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: own E - Wall- 12E -Obw 6 X 9 N - WaII- 12E -Obw 12 X 9 S -Wall-12E-Obw 2 X 9 E - GIs -RC shgc - 0.320 %S N - GIs -RC shgc - 0.35 0 %S UP- Ceil- 16CR -44 12 X 6 Subtotals for Structure: Infii.: Win.: 9.1, Sum.: 4.8 Ductwork: AED Excursion: Room Totals: Htg. & clg. 12.0 6.0 72.0 9.0 648.0 1 38 4 437 437 0.210 44 95.5 18 10 12.5 72 180 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. 0.068 0.068 0.068 0.310 0.310 0.022 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Cig: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 5.9 260 0.6 5.9 565 0.6 5.9 106 0.6 27.0 270 22.9 27.0 337 14.0 1.9 138 0.8 1,676 4.667 840 0.372 239 2,755 1 38 CFM 3.5 AC /hr 0 CFM 0 CFM 0 % 0 CFM 0 9 CFM 5 CFM ain< 0 28 0 61 0 12 0 229 0 175 0 60 0 565 112 67 57 124 112 814 C: \Elite \Rhvac 8\Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac - Residential & Light Commercial HVAC Loa Burr vdIe Heating & A/C Inc Burnsville. MN '55337 - . Detailed Room Loads -Room 11 - Family (Peak F enestration Gain Procedure e __ Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Room Length: 15.0 Room Width: 11.2 168.0 9.0 1,512.0 2 111 6 565 565 0.198 Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: W - WalI- 12E -Obw 11.2 X 9 N WaII- 12E-0bw 15 X 9 W - GIs -RC shgc -0.35 0 %S (2) N - GIs -RC shgc -0.37 0%S (2) W - GIs -RC shgc -0.37 0 %S UP- Ceil- 16CR -44 15 X 11.2 Subtotals for Structure: Infil.: Win.: 11.9, Sum.: 6.3 Ductwork: AED Excursion: Room Totals: 49.2 123 21.6 12 30 168 236 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wgJ100 ft. 0.068 0.068 0.310 0.300 0.300 0.022 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. CIg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 5.9 291 5.9 728 27.0 582 26.1 314 26.1 783 1.9 322 3,020 4.669 1,101 391 4,512 0.6 0.6 60.7 14.5 61.8 0.8 1 1 1 222 CFM 8.8 AC /hr 0 CFM 0 CFM 0 % 0 CFM 0 12 CFM 6 CFM 0 31 0 79 0 1,312 0 174 0 1,853 0 140 0 3,589 0.369 146 87 333 724 146 4,732 C: \Elite\Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rhvac Residential & Light Commercial HVAC Loads BumsviUe Heating 3 A/C In BumsviUe,'MN 55337. _ _ Detailed Room Loads Room 12 - Basement (Peak Fenestration e Software Development, Inc 3583 I Lemieux Circle Page 34 .Gerreral lk Room is in zone 2, which peaks at 5 pm Calculation Mode: Htg. & clg. Room Length: 42.9 Room Width: 36.0 Area: • 1,543.0 Ceiling Height: 9.0 Volume: 13,887.0 Number of Registers: 1 Runout Air: 550 Runout Duct Size: 12 Runout Air Velocity: 700 Runout Air Velocity: 700 Actual Loss: 0.118 N - Wall-R -5 wall 42.9 X 9 S -Wall-R-5 wall 42.9 X 9 E - Wall -R -5 wall 36 X 9 W - Wall- 12E -Obw 36 X 9 W - GIs -RC shgc -0.35 0 %S (2) W - Gls -RC shgc -0.35 0 %S W - GIs -RC shgc -0.35 0 %S (2) N - GIs -RC shgc -0.37 0 %S N - GIs -RC shgc -0.3 0 %S W - GIs -RC shgc -0.37 0 %S Floor- 21A -32 36 X 42.9 Subtotals for Structure: Infil.: Win.: 40.5, Sum.: 21.5 Ductwork: AED Excursion: Room Totals: ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 2 550 CFM 2.4 AC/hr 0 CFM 0 CFM 0 0 CFM 0 % 41 CFM 22 CFM 367.7 0.073 9.7 3,550 0.7 0 385.7 0.073 9.9 3,808 0.8 0 324 0.073 9.9 3,199 0.8 0 199 0.068 5.9 1,177 0.6 0 19.2 0.310 27.0 518 60.7 0 40.8 0.330 28.7 1,171 61.0 0 35 0.310 27.0 944 60.7 0 6 0.300 26.1 157 14.5 0 12 0.290 25.2 303 12.3 0 30 0.300 26.1 783 61.8 0 1543 0.020 1.7 2,685 0.0 0 18,295 0 806 4.669 3,763 0.371 500 2,094 24,152 500 268 300 252 127 1,166 2,487 2,126 87 147 1,853 0 ' 8,813 299 824 1,794 11,730 C: \Elite \Rhvac 8 \Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Net Required: Actual: 2.30 1.00 90% / 10% 77% / 23% 24,813 9,240 2,764 2,760 27,577 12,000 C:\Elite \Rhvac 8\Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM Rh:vac - Residential & Light Commercial HVAC Loads Elite Software ,Development, Burnsville Heating E.:' a 3583 Lemieux Burnsville; MN '55337J- ` , Pa4e lnc._ Circle 39 ;' System 1 Room Load Summary Run Runes _ Clq CI Mrn Act Romp �� � Area Sens Duct_ Duc Se s� Ig Sys No ,Name z 3 i . SF Btuh CAM Sue Vel,.. , � Btuh a _Btuh CFM - -Zone 1 - -- 1 Foyer 50 766 10 1 -2 398 185 28 9 9 2 Den 175 2,939 39 1 -5 244 711 116 33 33 3 Kitchen 280 2,206 30 1 -7 375 2,138 78 100 100 4 Dining 185 387 5 1 -2 426 198 0 9 9 5 Sunroom 180 7,047 94 2 -7 463 5,278 150 247 247 6 Master Bedroom 181 4,003 54 1 -8 536 3,992 611 187 187 7 Master Bath 252 2,614 35 1 -3 483 506 112 24 24 8 Laundry 108 1,165 16 1 -2 475 221 450 10 10 9 Back Entry 80 2,230 30 1 -3 364 381 100 18 18 10 Powder 72 2,755 37 1 -4 437 814 112 38 38 11 Family 168 4,512 60 2 -6 565 4,732 146 222 222 Zone 1 subtotal 1,731 30,625 410 19,156 1,903 897 897 -- -Zone 2 - -- 12 Basement 1,543 24,152 323 1 -12 700 11,730 500 550 550 Zone 2 subtotal 1,543 24,152 323 11,730 500 550 550 Duct Latent 361 System 1 total 3,274 54,777 733 24,813 2,764 1,162 1,162 System 1 Main Trunk Size: 12x17 in. Velocity: 821 ft./min Loss per 100 ft.: 0.095 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. m N r tetiimSuma $ _ ! enslbl e c _ �� S at of Net Required: Actual: 2.30 1.00 90% / 10% 77% / 23% 24,813 9,240 2,764 2,760 27,577 12,000 C:\Elite \Rhvac 8\Ron Clark Briarwood Right.rhv Monday, February 14, 2011, 11:07 AM