3585 Lemieux Cir - Energy Calcs
a 2, A pize/sg.. New Construction Energy Code Compliance Certificate RECEIVED FEB I 5 Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Mailing Address of the Dwelling or DweWng Unit 3585 LEMIEUX CIRCLE Name of Residential Contractor RON CLARK CONSTRUCTION THERMAL ENVELOPE RADON SYSTEM Insulation Location Foundation Wall Perimeter ef Stab on Grade Rim Joist (Foundation) Rim Joist (1 Floor+) Wall (.'eiling, flat Ceiling, vaulted Bay Windows or cantilevered areaa ( ) Bonus room over garage I)escribe other insulated sireas . . 0 0 5) o 04 V E 2 4 5 10 1 0. 19 44 44 Type: Check All That Apply X x. city EAGAN MN License Number 1221 X X X X Date Certificate Posted X X X Ron Clark Construction & Design Aolooprovc/.0:04#100ipow*:;:::: other systert nwrntoring device) Passive (No Fan) Other Please Describe Here Type in location: exterior Type in location: interior Type in Locaton. interior Windows & Doors Solar Heat Gain Coefficient (SHGC): 31/ Average U (excludes skylights and one door) U: 3/ MECHANICAL SYSTEMS p Appliances Heating System Heating or Cooling Ducts Outside Conditioned Spaces Not applicable, all ducts located in conditioned space R-value Domestic Water Heater Cooling System Make up Air Select a Type X Not required per mech. code Manufacturer Rating or Size StiUtUre Efficiency GAS ................„.............. BRYANT Input in BTUS: 92% AFUE or HSPF% 80,000 Marathon 05245 Capacity in Gallons: 105 ELECTRIC BRYANT 11 3ANA036 Output in Tons: Heat Gain SEER: Calculated cooling load: 3 13 33,500 5 Mechanical Ventilation System Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Select Type Heat Recover Ventilator (HRV) Capacity in cfms Energy Recover Ventilator (ERV) Capacity in cfms Continuous exhausting fan(s) rated capacity in cfms Low: Low: Location of fan(s), describe: Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 117 High: High: 189 Passive Powered Interlocked with exhaust device. Describe: Other, describe: Location of duct or system: Cfm's Basement " round duct OR " metal duct Combustion Air Select a Type Not required per mech. code Passive 6" Other, describe: Location of duct or system: Basement Cfm's " round duct OR " metal duct Created by BAM version 052009 /Z vlEAip ,2 P i " 3585 Lemieux Circle HVAC Load Calculations for Ron Clark R H VAC R"I"" HVAC Lomas Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Prepared By: Alan Dobson Bumsville Heating & A/C Inc. 3451w Bumsville Pkwy, Suite 120 Bumsville,MN 55337 952- 894 -0005 Monday, February 14, 2011 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:40 AM Rhvac Residential & LightComme HVAC Loads Ebte software Development, Inc. B - ifiele Heating & A /C Inc * 3585 Lenueux Circle �"Burnsvife; MN 55337 '. . t - _ y a = ri; 2 Paife 2. Project Report i Ganes P ® rnformatlon _ _ Project Title: 3585 Lemieux Circle Designed By: Alan Dobson Project Date: Monday, February 14, 2011 Project Comment: Client Name: Ron Clark Company Name: Burnsville Heating & NC inc. Company Representative: Alan Dobson Company Address: 3451w Burnsville Pkwy, Suite 120 Company City: Bumsville,MN 55337 Company Phone: 952- 894 -0005 Company Fax: 952 - 894 -0925 Company Comment: Reference City: Minneapolis, Minnesota Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum ReLHum Dry Bulb Difference Winter -15 -15.33 80% Na 72 n/a Summer 88 73 50% 50% 75 35 Check Figures Total Building Supply CFM: 1,215 CFM Per Square ft.: Square ft. of Room Area: 3,274 Square ft. Per Ton: Volume (ft of Cond. Space: 29,459 0.371 1,369 Building Loads Total Heating Required Including Ventilation Air 54,727 Btuh 54.727 MBH Total Sensible Gain: 25,937 Btuh 90 % Total Latent Gain: 2,763 Btuh 10 % Total Cooling Required Including Ventilation Air 28,700 Btuh 2.39 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be. sure to select a unit that meets both sensible and latent loads. C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:40 AM C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:40 AM Rhvac Residential &t Commercial HVAC Loads Eide Software Development, Inc Bumsville Heating t: Inc Bumsvilie, W:55337 -„ .. 3585 Lemieux C - = Page 3 ; Miscellaneous Report 'Fr Data Ma _L -0 r � n �� oo>_ #?utdi r £ Qutdoat, _, , indd o _ ��: Gratr - I mo. N- D Bulb_ ._ 13�i1t 1 am ____ F . � Dn�13a�b� D er nce> Winter -15 - 15.33 800 n/a 72 n/a Summer: 88 73 50% 50% 75 35.17 € Duct Sizi "` • I • " "ts m 1:;; .: - s - --;g---' _ -774 . Main Trunk Runouts Calculate: Yes Yes Use Schedule: No No Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg. /100 ft. 0.1000 in.wg. /100 ft. Minimum Velocity: 650 ft. /min 450 ft. /min Maximum Velocity: 900 ft. /min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data:: _: ° � E ` .° . - __' Winter Summer Infiltration Specified: 0.320 AC /hr 0.170 AC/hr 125 CFM 66 CFM Infiltration Actual: 0.320 AC /hr 0.170 AC/hr Above Grade Volume: X 23.457 Cu.ft. X 23.457 Cu.ft. 7,506 Cu.ft./hr 3,988 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 125 CFM 66 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1— Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.20 = (0.68 X 0.970 X 35.17 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC /hr (125 CFM), Construction: Average Summer Infiltration Specified: 0.170 AC/hr (66 CFM), Construction: Average ••D'= SLoaate a Sdebitt as40 r — -,. s = ' Surfed r ®o r N ® T, • e De c am . a ti o r _ .n t✓e ■ _ Le r>■ "kV : - r 1 Supply Main Attic 168 0.12 6 150 No 1 Return Main Attic 16B 0.24 6 56 No C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:40 AM C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Rhvac Residential 8, Lig ht Commercial HVAC Loads Elite Software Development, inc Bumsmile Heating 8, Inc 3585 Lemieux Circle Bumsvtile, MN "55397 � .' } . _ -'3 = .._ `Page° 10 Total Building Summary Loads RDescnptio ©uan Loss taa _ Gai RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 167.6 4,521 0 5,722 5,722 SHGC 0.35 RC: Glazing -RC, ground reflectance= 0.23, u -value 0.3, 25.2 659 0 392 392 SHGC 0.37 1A -ry -d: Glazing - Single pane, sliding glass door, 40.8 - '1,171 0 828 828 reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 RC: Glazing -RC, u -value 0.3, SHGC 0.37 60 1,566 0 2,310 2,310 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 0 1,591 1,591 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 0 113 113 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 1,155 Front Door: Door - Brandl Front Door 20.4 248 0 69 69 door: Door - 19 282 0 78 78 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 1608.3 9,515 0 1,028 1,028 cavity, no board insulation, brick finish, wood studs R -5 wall: Wall- Basement, , R -5 board with poured wall 1077.5 10,557 0 820 820 16CR- 44-ad: Roof/Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R -44 insulation, dark asphalt 20P -10-c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 Passive, R -10 board insulation, carpet covering 19A -30p: Floor -Over enclosed unconditioned crawl 130.4 324 0 48 48 space, No insulation on exposed walls, sealed or vented space, passive, R -30 blanket 21 A -32 -v: Floor- Basement, Concrete slab, any thickness, 1543 2,685 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 32' wide Subtotals for structure: 38,363 0 15,716 15,716 People: 2 460 600 1,060 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 4,750 360 2,168 2,528 Infiltration: Winter CFM: 125, Summer CFM: 66' 11,614 1,543 923 2,466 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 5,330 5,330 Total Building Load Totals: 54,727 2,763 25,937 28,700 C _ .� y ._ �xe ck ® :� _ �:.:.� ��� - �� -�f ��:����� �.5�' � .�P. _ .��- � Total Building Supply CFM: 1,215 CFM Per Square ft.: 0.371 Building Square ft. of Room Area: 3,274 Square ft. Per Ton: 1,369, Volume (ft of Cond. Space: 29,459 :Br itdi • Loa , Total Heating Required Including Ventilation Air 54,727 Btuh 54.727 MBH Total Sensible Gain: 25,937 Btuh 90 % Total Latent Gain: 2,763 Btuh 10 % Total Cooling Required Including Ventilation Air: 28,700 Btuh 2.39 Tons (Based On Sensible + Latent) 4 _ __. Notes §�' ��. :� �. ;.�.:Y�;� -� �- - 7 ��_ Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM em, load Rhvac Residential & Light Commercial -HVAC L oa BumswUe :Beating "& NC Inc Burnsville-VW 55337 System 1 Main Floor Summary Loads De RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 167.6 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 25.2 SHGC 0.37 1 A -ry -d: Glazing- Single pane, sliding glass door, 40.8 reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 RC: Glazing -RC, u -value 0.3, SHGC 0.37 60 1,566 0 2,310 2,310 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 0 1,591 1,591 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 0 113 113 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 1,155 Front Door: Door - Brandl Front Door 20.4 248 0 69 69 door: Door - 19 282 0 78 78 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 1608.3 9,515 0 1,028 1,028 cavity, no board insulation, brick finish, wood studs R -5 wall: Wall- Basement, , R -5 board with poured wall 1077.5 10,557 0 820 16CR- 44-ad: Roof /Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R -44 insulation, dark asphalt 20P -10-c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 Passive, R -10 board insulation, carpet covering 19A -30p: Floor -Over enclosed unconditioned crawl 130.4 324 space, No insulation on exposed wails, sealed or vented space, passive, R -30 blanket 21 A -32 -v: Floor- Basement, Concrete slab, any thickness, 1543 2,685 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 32' wide Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 125, Summer CFM: 66 Ventilation: Winter CFM: 0, Summer CFM: 0 AED Excursion: System 1 Main Floor Load Totals: Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: 54,727 Btuh 25,937 Btuh 2,763 Btuh 28,700 Btuh 2 54,727 Supply CFM: 1,215 CFM Per Square ft.: Square ft. of Room Area: 3,274 Square ft. Per Ton: Volume (ft of Cond. Space: 29,459 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C: \Elite\Rhvac 8\Ron Clark Briarwood 3585 Lemieux Circle.rhv Total Gain= 4,521 0 5,722 5,722 659 0 392 392 1,171 0 828 828 48 820 1,446 48 38,363 0 15,716 15,716 460 600 1,060 400 1,200 1,600 0 0 4,750 360 2,168 2,528 1 1,614 1,543 923 2,466 0 0 0 0 0 0 5,330 5,330 2,763 25,937 28,700 Ceck =l= a' `re 0.371 1,369 54.727 MBH 90 % 10 % 2.39 Tons (Based On Sensible + Latent) Monday, February 14, 2011, 9:41 AM foot System 1, Zone 1 Load Totals: ,FS•14.aaMs Supply CFM: 1,002 CFM Per Square ft.: Square ft. of Room Area: 1,731 Square ft. Per Ton: Voiume (ft of Cond. Space: 15,572 Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv 30,573 Btuh 21,381 Btuh 1,903 Btuh 23,284 Btuh 30,573 1,903 21,381 23,284 5 lobe =oac W itt 0.579 892 30.573 MBH 92 % 8 % 1.94 Tons (Based On Sensible + Latent) b `� Monday, February 14, 2011, 9:41 AM Rhvac Residential & Light Commercial HVAC Loads Burnsville Heating & _NC Inc, < _ Bumsvife;_ MN :55337--: . = Elite Software Development, Inc. 3585 Lemieux Circle' _` age 17_ System 1, Zone '1 Summary Loads (Peak Load Procedure for Rooms moonen -r Ko��a De sc "• o =akt �Gatn° _. 4 Gal ro ta. _ .fin; RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 113.4 3,059 0 3,622 3,622 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 19.2 502 0 327 327 SHGC 0.37 1 A -ry -d: Glazing - Single pane, sliding glass door, reflective, vinyl frame, ground reflectance = 0.23, u- value 0.33, SHGC 0.35 40.8 1,171 0 828 828 RC: Glazing -RC, u -value 0.3, SHGC 0.37 60 1,566 0 2,310 2,310 Front Door: Door - Brandl Front Door 20.4 248 0 69 69 door Door- 19 282 0 78 78 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud cavity, no board insulation, brick finish, wood studs 1409.3 8,338 0 901 901 16CR- 44 -ad: Roof /Ceiling -Under Attic with Insulation on 1730.2 3,312 0 1,446 1,446 Attic Floor (also use for Knee Walls and Partition Ceilings), vented attic with radiant barrier, R-44 insulation, dark asphalt 20P -10-c: Floor -Over open crawl space or garage, 179.6 1,266 0 116 116 Passive, R -10 board insulation, carpet covering 19A -30p: Floor -Over enclosed unconditioned crawl space, No insulation on exposed walls, sealed or vented space, passive, R -30 blanket 130.4 324 0 48 48 Subtotals for structure: 20,068 0 14,122 14,122 People: 2 460 600 1,060 Equipment: 400 1,200 1,600 Lighting: 0 0 0 Ductwork: 2,654 0 1,398 1,398 Infiltration: Winter CFM: 85, Summer CFM: 45 7,851 1,043 624 1,667 System 1, Zone 1 Load Totals: ,FS•14.aaMs Supply CFM: 1,002 CFM Per Square ft.: Square ft. of Room Area: 1,731 Square ft. Per Ton: Voiume (ft of Cond. Space: 15,572 Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv 30,573 Btuh 21,381 Btuh 1,903 Btuh 23,284 Btuh 30,573 1,903 21,381 23,284 5 lobe =oac W itt 0.579 892 30.573 MBH 92 % 8 % 1.94 Tons (Based On Sensible + Latent) b `� Monday, February 14, 2011, 9:41 AM C: \Elite\Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Rhvac ResidentMAL & Light Commercial HVAC Loads 8um sville Heating & WC Inc'- a3u msville ' MN 5533T Elite Software Development, Inc. =3585 Lemi Circle ` Pa ge 18 f System 1, Zone 2 Summary Loads (Peak Load Procedure for Rooms Component, z e YArea se , De ist a �itir4 , f LA t soot, : dgro T ot al G atrr, . ,:Gam RC: Glazing -RC, ground reflectance = 0.23, u -value 0.31, 54.2 1,462 ` 0 2,100 2,100 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.33, 40.8 1,171 0 1,591 1,591 SHGC 0.35 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.3, 6 157 0 65 65 SHGC 0.37 RC: Glazing -RC, ground reflectance = 0.23, u -value 0.29, 12 303 0 113 113 SHGC 0.3 RC: Glazing -RC, u -value 0.3, SHGC 0.37 30 783 0 1,155 1,155 R -5 wall: Wall- Basement, , R -5 board with poured wall 1077.5 10,557 0 820 820 12E -Obw: Wall- Frame, R -19 insulation in 2 x 6 stud 199 1,177 cavity, no board insulation, brick finish, wood studs 0 127 127 21A -32 -v: Floor- Basement, Concrete slab, any thickness, 1543 2,685 0 0 0 2 or more feet below grade, no insulation below floor, vinyl covering, shortest side of floor slab is 32' wide Subtotals for structure: 18,295 0 8,813 8,813 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 2,097 0 770 770 Infiltration: Winter CFM: 41, Summer CFM: 22 3,763 500 299 799 System 1, Zone 2 Load Totals: 24,155 500 11,775 12,275 Supply CFM: 552 CFM Per Square ft.: 0.358 Square ft. of Room Area: 1,543 Square ft. Per Ton: 1,508 Volume (ft of Cond. Space: 13,887 Zone Loads Total Heating Required: 24,155 Btuh 24.155 MBH Total Sensible Gain: 11,775 Btuh 96 % Total Latent Gain: 500 Btuh 4 % Total Cooling Required: 12,275 Btuh 1.02 Tons (Based On Sensible + Latent) I Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. C: \Elite\Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Room Totals: C: \Elite\Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv 767 28 186 Monday, February 14, 2011, 9:41 AM [ Rhvac Residential '& Light Commercial HVAC Load i BumsviUe Heating & NC Inc I Birnsville.MN 55337 Ide Software Develpment, Inc." r. � = 3585 Lemieux Circle -Pace 23 Detailed Room Loads - Room 1 - Foyer (Peak Fenestration Gain Procedure) Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 5.0 ft. Zone Number: 1 Area: 50.0 sq.ft. Supply Air: 9 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 1.2 AC/hr Volume: 450.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 9 CFM Percent of Supply.: 0 % Runout Duct Size: 2 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 400 ft. /min. Percent of Supply: 0 % Runout Air Velocity: 400 ft. /min. Actual Winter Infil.: 2 CFM Actual Loss: 0.482 in.wg. /100 ft. Actual Summer Infil.: 1 CFM lteArea D c ® k� ; ; mot, .CI cif b 'en ` Q uan t a - � � ague � � k�TM - .... 1oss� � �. C I ® � M .� 1= ' �t �Sen E - Wall- 12E -Obw 5 X 9 24.6 0.068 5.9 146 0.6 0 16 E - Door -Front Door 3 X 6.8 20.4 0.140 12.2 248 3.4 0 69 E - CeiI- 16CR -44 10 X 5 50 0.022 1.9 96 0.8 0 42 Subtotals for Structure: 490 0 127 j Infil.: Win.: 2.3, Sum.: 1.2 45 4.667 210 0.378 28 17 Ductwork: 67 12 AED Excursion: 30 Room Totals: C: \Elite\Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv 767 28 186 Monday, February 14, 2011, 9:41 AM C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Rhvac Residential'& Light Commercial HVAC Loads' - Burnsville Heating & NC In -_ Burnsville, MN ,55337 _ - - - Elite Software Development, Inc 3585 L8m1eUX Circle - 3 : ` - °Pa9`e,24 Detailed Room Loads - Room 2 - Den Peak Fenestration Gain Procedure tGenerat ° x L 4 = P 4- Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.6 ft. System Number: 1 Room Width: 11.2 ft. Zone Number: 1 Area: 175.0 sq.ft. Supply Air: 53 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 1,572.0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 53 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 390 ft. /min. Percent of Supply: 0 % Runout Air Velocity: 390 ft. /min. Actual Winter Infil.: 9 CFM Actual Loss: 0.122 in.wg. /100 ft. Actual Summer Infil.: 5 CFM tem��` �� De sc .. ;tia Area° uant Wafu kltg�QS�Cia 1 1-kM _ _ _ osa�_ M__,s . �Gat �Sersy E - Wall- 12E -Obw 11.2 X 9 100.8 0.068 5.9 596 0.6 0 64 N - Wall- 12E -Obw 4.2 X 9 37.8 0.068 5.9 224 0.6 0 24 S - Wall- 12E -Obw 5.4 X 9 31.1 0.068 5.9 184 0.6 0 20 S - GIs -RC shgc -0.32 0 %S 17.5 0.310 27.0 472 31.7 0 555 UP- CeiI- 16CR -44 15.6 X 11.2 174.7 0.022 1.9 334 0.8 0 146 Subtotals for Structure: 1,810 0 809 Infil.: Win.: 9.4, Sum.: 5.0 187 4.669 874 0.369 116 69 Ductwork: 255 74 AED Excursion: 182 Room Totals: 2,939 116 1,135 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Rhvac` Residential & Light Commercial HVAC Loa `BumsvUle Heating &;A /C Inc r BurnsviOe; 55337. Detailed Room Loads Room 3 f General : i a.�wta Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Room Length: 14.0 ft. Room Width: 20.0 ft. Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: S -W aU- 12E -Obw 14 X 9 118.8 S - GIs -RC shgc -0.37 0 %S 7.2 UP- CeiI -16CR -4414 X 20 280 AED Excursion: Equipment: Room Totals: - Kitchen 280.0 sq.ft. 9.0 ft. 2,520.0 cu.ft. 1 110 CFM 7 in. 411 ftmin. 411 ft/min. 0.085 in.wg./100 ft. 0.068 0.300 0.022 (Peak Fe Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. CIg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Ira: 5.9 26.1 1.9 Fenestration Gain Procedure) 703 188 536 2,207 0.6 35.7 0.8 Subtotals for Structure: 1,427 Infil.: Win.: 6.3, Sum.: 3.4 126 4.667 588 0.373 Ductwork: 192 Software Oevatop unit, Inc - Lemieux Circle _ Page =25' 1 1 1 110 CFM 2.6 AC /hr 0 CFM 0 CFM 0 % 0 CFM 0 % 6 CFM 3 CFM 0 76 0 257 0 234 0 567 78 47 153 377 0 1,200 78 2,344 C:\Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM • • te Software De elopment, Inc.. 3585 Lemieux Circle * "PaVe Detailed Room Loads - Room 4 - Dining (Peak Fenestration Gain Procedure) escn•tio Oenerat Y Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: UP- Cei1- 16CR -44 15 X 12.3 Subtotals for Structure: Infil.: Win.: 0.0, Sum.: 0.0 Ductwork: AED Excursion: Room Totals: Htg. & clg. Occurrences: 1 15.0 ft. System Number: 1 12.3 ft. Zone Number: 1 185.0 sq.ft. Supply Air: 9 CFM 9.0 ft. Supply Air Changes: 0.3 AC /hr 1,661.0 cu.ft. Req. Vent. Clg: 0 CFM 1 Actual Winter Vent.: 0 CFM 9 CFM Percent of Supply.: 0 % 2 in. Actual Summer Vent.: 0 CFM 427 ft. /min. Percent of Supply: 0 % 427 ft. /min. Actual Winter Infil.: 0 CFM 0.550 in.wg. /100 ft. Actual Summer Infil.: 0 CFM 184.5 0.022 0 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circie.rhv 353 0.8 0 154 353 0 154 0 0 0 0 0 34 13 32 387 0 199 Monday, February 14, 2011, 9:41 AM Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: rGenerat =i. Room is in zone 1, which peaks at 5 pm Htg. & clg. 14.6 12.3 180.0 9.0 1,616.0 2 149 7 558 558 0.156 Rhvac - Residential &;Light Commercial HVAC Loads I3 umsvi ll e Heating A NC Inc Burnsville;: MN: °55337 Detailed Room Loads - Room 5 - SunroomPeak Fenestration Gain Procedure) W - Wall- 12E -Obw 12.3 X 9 S - Wall- 12E -Obw 14.6 X 9 W - GIs -RC shgc -0.35 0 %S (2) S - Gls- 1A-rv-d shgc -0.35 0 %S W GIs-RC shgc -0.37 0 %S UP-CeiI-16CR-44 14.6 X 12.3 Floor- 20P -10 12.3 X 14.6 Floor- 19A -30p 12.3 X 10.6 Subtotals for Structure: Infil.: Win.: 12.2, Sum.: 6.5 Ductwork: AED Excursion: Room Totals: 61.5 90.6 19.2 40.8 30 179.6 179.6 130.4 - ft. ft. sq.ft. ft. cu.ft. 242 CFM in. ft. /min. ft. /min. in.wg. /100 ft. 0.068 0.068 0.310 0.330 0.300 0.022 0.081 0.034 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. CIg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 5.9 364 5.9 536 27.0 518 28.7 1,171 26.1 783 1.9 344 7.0 1,266 2.5 324 5,306 4.667 1,130 612 7,048 Software Development, Inc. Lemie Circle Page 27 1 1 1 298 CFM 11.1 AC /hr 0 CFM 0 CFM 0 % 0 CFM 12 CFM 6 CFM n- th 0.6 0 39 0.6 0 58 60.7 0 1,166 34.4 0 1,404 61.8 0 1,853 0.8 0 150 0.6 0 116 0.4 0 48 0 4,834 0.372 150 90 416 1,023 150 6,363 C: \Elite \Rhvac 81Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM General` u _ Room is in zone 1, which peaks at 5 pm Se Software Developm fad, Inc. 3585 Lemieux Circle' :Pa =e28! _Rhwicr Residential & Light Commercial HVAC Load Burnsv�Ne I{eahng &A/C Inc Burnsville -MN :.55337 Detailed Room Loads - Room 6 - Master Bedroom (Peak Fenestration Gain Procedure) Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 14.4 12.6 181.0 9.0 1,633.0 2 94 6 478 478 0.143 1W - Wall- 12E -Obw 12.6 X 9 78.4 N - Wall- 12E -Obw 14.4 X 9 '129.6 W - GIs-RC shgc -0.35 0 %S (2) 35 U P- Ceil -16CR- 4414.4 X 12.6 181.4 Subtotals for Structure: !nth.: Win.: 12.2, Sum.: 6.5 Ductwork: 1 AED Excursion: People: 230 lat/per, 300 sen/per: Room Totals: 243 2 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 0.068 5.9 464 0.6 0.068 5.9 767 0.6 0.310 27.0 944 60.7 0.022 _ 1.9 347 0.8 2,522 4.667 1,134 0.370 348 4,004 1 1 1 188 CFM 6.9 AC /hr O CFM O CFM O % O CFM 0 12 CFM 6 CFM 0 50 0 83 0 2,126 0 152 0 2,411 151 90 262 644 460 600 611 . 4,007 Monday, February 14, 2011, 9:41 AM Rhvec Resident & Light Commercial HVAC Loads B urnsviNe Heating 81 A/C Inc Bumsville,. MN , 55337_. Detailed Room Loads - Room 7 - Master Bath Room is in zone 1, which peaks at 5 pm Htg. & clg. Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: N - Wall- 12E -Obw 20 X 9 UP- Ceil- 16CR -44 20 X 12.6 Subtotals for Structure: Infil.: Win.: 9.1, Sum.: 4.8 Ductwork: AED Excursion: Room Totals: Occurrences: 20.0 ft. System Number: 12.6 ft. Zone Number: 252.0 sq.ft. Supply Air: 9.0 ft. Supply Air Changes: 2,268.0 cu.ft. Req. Vent. Cig: 1 Actual Winter Vent.: 24 CFM Percent of Supply.: 3 in. Actual Summer Vent.: 485 ft. /min. Percent of Supply: 485 ft. /min. Actual Winter Infil.: 0.390 in.wg. /100 ft. Actual Summer Infil.: HTM 180 0.068 5.9 1,065 252 0.022 1.9 482 1,547 180 4.667 840 227 Software Development, Inc. 358 Lemreuz Circle :Page 2 9. Peak Fenestration Gain Procedure 2,614 1 1 1 24 CFM 0.6 AC /hr O CFM 0 CFM O % O CFM O % 9 CFM 5 CFM 0.6 0 115 0.8 0 211 0 0.372 112 326 67 33 82 112 508 C: \Elite \Rhvac 8\Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011,9 :41 AM C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circie.rhv Monday, February 14, 2011, 9:41 AM ' Rhvac Residential & Light Commercial HVAC Loads BUM Heating & A/C Inc _ [BumsviNe,YMN 55337 _ __ = - - . _.. ».,_,: El Software Development, Inca _ S z 3585 Lemieux Circle= ` t r ± Page30 Detailed Room Loads - Room 8 - Laundry (Peak Fenestration Gain Procedure) . , y ' 1 General :1 -:- - ,_s Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 9.0 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 108.0 sq.ft. Supply Air: 10 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 0.6 AC/hr Volume: 972.0 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: - 10 CFM Percent of Supply.: 0 % Runout Duct Size: 2 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 477 ft. /min. Percent of Supply: 0 Runout Air Velocity: 477 ft. /mina Actual Winter Infil.: 4 CFM Actual Loss: 0.684 in.wgf100 ft. Actual Summer !nth.: 2 CFM It Area�� �U-�f Hfg er Clg La Sen Descriptron, Quan • r � / al ua 1-os G l n � N - WaII- 12E -Obw 9 X 9 " - 81 0.068 5.9 479 0.6 0 52 UP- CeiI- 16CR -44 9 X 12 108 0.022 1.9 207 0.8 0 90 Subtotals for Structure: 686 0 142 Infil.: Win.: 4.1, Sum.: 2.2 81 4.667 378 0.370 50 30 Ductwork: 101 15 AED Excursion: 36 Equipment: 400 0 Room Totals: 1,165 450 222 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circie.rhv Monday, February 14, 2011, 9:41 AM cite Software Development, Inc: 3595 Lemieux Circle Peak Fenestration Gain Procedure Rhvac Residential &Light Commercial HVAC Loa Bu rnsville Heating & A/C in Burnsville, MN 55337 i Detailed Room Loads Room 9 Back Ent Room is in zone 1, which peaks at 5 pm Calculation Mode: Htg. & clg. Room Length: 8.0 ft. Room Width: 10.0 ft.' Area: 80.0 sq.ft. Ceiling Height: 9.0 ft. Volume: 720.0 cu.ft. Number of Registers: 1 Runout Air: 18 CFM Runout Duct Size: 3 in. Runout Air Velocity: 365 ft. /min. Runout Air Velocity: Actual Loss: %lie Descri ®tk N - Wall- 12E -0bw 8 X 9 E - Wall- 12E -Obw 10 X 9 j. E - Door -door 2.8 X 6.8 UP- CeiI- 16CR -44 8 X 10 Subtotals for Structure: Infil.: Win.: 8.1, Sum.: 4.3 Ductwork: AED Excursion: Room Totals: Occurrences: System Number. Zone Number: Supply Air: Supply Air Changes: Req. Vent. Cig: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: 365 ft./min. Actual Winter Infil.: 0.223 in.wgil 00 ft. Actual Summer Infil.: Arse 162 1 1 1 18 CFM 1.5 AC/hr 0 CFM 0 CFM 0`% 0 CFM 0 8 CFM 4 CFM osse • H'M; 72 0.068 5.9 426 0.6 0 46 71 0.068 5.9 420 0.6 0 45 19 0.170 14.8 282 4.1 0 78 80 0.022 1.9 153 0.8 0 67 1,281 0 236 4.667 756 0.370 100 60 194 25 61 2,231 100 383 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Ift software Developme 35t35 L e mieux circle 32 Rhvac : Residential: &.Light Commercial HVAC Bumsviile Heating & A/C Inc Bui nsv ile 'MN 55337 Detailed Room Loads Room 10 - Powder (Peak Fenestration Gain Procedure) C h tCieneraf_ _ER ". x � E 1 ... C Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Subtotals for Structure: [nfil.: Win.: 9.1, Sum.: 4.8 Ductwork: AED Excursion: Room Totals: Htg. & clg. Occurrences: 12.0 ft. System Number 6.0 ft. Zone Number 72.0 sq.ft. Supply Air: 9.0 ft. Supply Air Changes: 648.0 cu.ft. Req. Vent. Clg: 1 Actual Winter Vent.: 54 CFM Percent of Supply.: 4 in. Actual Summer Vent.: 613 ft. /min. Percent of Supply: 613 ft. /min. Actual Winter Infil.: 0.411 in.wg./100 ft. Actual Summer Infil.: Gain E - Wall- 12E -Obw 6 X 9 44 0.068 5.9 260 0.6 0 28 S - Wall- 12E -Obw 12 X 9 95.5 0.068 5.9 565 0.6 0 61 N - Wall- 12E -Obw 2 X 9 18 0.068 5.9 106 0.6 0 12 E - GIs -RC shgc -0.32 0 %S 10 0.310 27.0 270 22.9 0 229 S - GIs -RC shgc -0.35 0 %S 12.5 0.310 27.0 337 342 0 427 UP-CeiI-16CR-44 12 X 6 72 0.022 1.9 138 0.8 0 60 • 1 1 1 54 CFM 5.0 AC /hr 0 CFM 0 CFM O % O CFM O % 9 CFM 5 CFM 1,676 180 4.667 840 0.372 112 0 239 2,755 112 1,142 817 67 75 184 C:\Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM R hvac - Residential & LigMComme HV AC Lo i B msv Nek eating& NC In BCknsviUe;_MN 55337 Detailed Room Loads - Room 11 - Family (Peak Fenestration Gain Procedure) „General Room is in zone 1, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: W - Wall- 12E -Obw 11.2 X 9 S - Wall- 12E -Obw 15 X 9 W - GIs -RC shgc -0.35 0 %S (2) S - GIs -RC shgc - 0.370 %S (2) W - GIs -RC shgc -0.37 0 %S UP- Cei1-16CR -4415 X 11.2 Subtotals for Structure: l nfil.: Win.: 11.9, Sum.: 6.3 Ductwork: AED Excursion: Room Totals: Htg. & clg. 15.0 11.2 168.0 9.0 1,512.0 2 115 6 584 584 0.211 ft ft. sq.ft. ft. cu.ft. CFM in. ft. /min. Occurrences: System Number. Zone Number: Supply Air: Supply Air Changes: Req. Vent. Cig: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: ftfmin. Actual Winter Infil.: in.wg. /100 ft. Actual Summer Infil.: 51.6 0.068 5.9 305 123 0.068 5.9 728 19.2 0.310 27.0 518 12 0.300 26.1 314 30 0.300 26.1 783 168 0.022 1.9 322 0.6 0.6 60.7 35.7 61.8 0.8 2,970 236 4.669 1,101 0.369 387 1 1 1 229 CFM 9.1 AC/hr O CFM 0 CFM 0 % O CFM O % 12 CFM 6 CFM �irrt 0 33 0 79 0 1,166 0 428 I' 0 1,853 0 140 0 3,699 146 87 1! 320 787 4,458 146 4,892 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011,9:41 AM tte Software Development, inc., 3 585 Lemieux Circle'` Detailed Room Loads - Room 12 - Basement (Peak Fenestration Gain Procedure) General -= ,I a , 6 e H 1 Room is in zone 2, which peaks at 5 pm Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: 7Ser E Itet t - 0 ; N - Wall -R -5 wall 42.9 X 9 S - Wall -R -5 wall 42.9 X 9 E - Wall -R -5 wall 36 X 9 W - Wall- 12E -Obw 36 X 9 W - GIs -RC shgc -0.35 0 %S (2) W - Gts -RC shgc -0.35 0 %S W - GIs -RC shgc -0.35 0 %S (2) N - GIs -RC shgc -0.37 0 %S N - GIs -RC shgc -0.3 0 %S W - GIs-RC shgc -0.37 0 %S Floor- 21A -32 36 X 42.9 Subtotals for Structure: InfiL: Win.: 40.5, Sum.: 21.5 Ductwork: AED Excursion: Room Totals: Htg. & clg. 42.9 36.0 1,543.0 9.0 13,887.0 1 552 12 702 702 0.119 ft. ft. sq.ft. ft. cu.ft. CFM in. ft. /min. ft. /min. in.wg. /100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Cig: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter lnfil.: Actual Summer Infil.: 1 1 2 552 CFM 2.4 AC /hr 0 CFM 0 CFM 0 % 0 CFM 0 % 41 CFM 22 CFM 367.7 0.073 9.7 3,550 0.7 0 268 385.7 0.073 9.9 3,808 0.8 0 300 324 0.073 9.9 3,199 0.8 0 252 199 0.068 5.9 1,177 0.6 0 127 19.2 0.310 27.0 518 60.7 0 1,166 40.8 0.330 28.7 1,171 61.0 0 2,487 35 0.310 27.0 944 60.7 0 2,126 6 0.300 26.1 157 14.5 0 87 12 0.290 25.2 303 12.3 0 147 30 0.300 26.1 783 61.8 0 1,853 1543 0.020 1.7 2,685 0.0 0 0 18,295 0 8,813 806 4.669 3,763 0.371 500 299 2,097 770 1,893 24,155 500 11,775 C: \Elite\Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM Rhvac Residential & Comm ercial HVAG Load Bumsvdle Heating & A/C In B umsville MN I ystem 1 Room Load Summary ide So_ ttware_ Cnc 3585 Lemlew Circle � � � _ �� .. may. ar_.�xstuil }' .�- �tM_:- �5tze:_ - � �e� �`�" gtu - � - -Zone t - -- .. , - _;Btu ,�. � -eFt4� : � G : - 1 Foyer 50 767 10 1 -2 400 186 28 9 9 2 Den 175 2,939 39 1 -5 390 1,135 116 53 53 3 Kitchen 280 2,207 30 1 -7 411 2,344 78 110 4 Dining 185 387 5 1 -2 427 199 0 9 9 5 Sunroom 180 7,048 94 2 -7 558 6,363 150 298 298 6 Master Bedroom 181 4,004 54 2 -6 478 4,007 611 188 188 7 Master Bath 252 2,614 35 1 -3 485 508 112 24 24 8 Laundry 108 1,165 16 1 -2 477 222 450 10 10 9 Back Entry 80 2,231 30 1 -3 365 383 100 18 18 10 Powder 72 2,755 37 1 -4 613 1,142 112 54 54 11 Family 168 4,458 60 2 -6 584 4,892 146 229 229 Zone 1 subtotal 1,731 30,573 409 21,381 1,903 1,002 1,002 - -Zone 2 -- 12 Basement 1,543 24,155 323 1 -12 702 11,775 500 552 552 Zone 2 subtotal 1,543 24,155 323 11,775 500 552 552 360 System 1 total 3,274 54,727 733 25,937 2,763 1,215 1,215 Duct Latent System 1 Main Trunk Size: 12x17 in. Velocity: 858 ft./min Loss per 100 ft.: 0.103 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. Cao1i gS'Y Summa-:_ Net Required: Actual: 90% / 10% 77% / 23% 9,240 2,760 110 12,000 C: \Elite \Rhvac 8 \Ron Clark Briarwood 3585 Lemieux Circle.rhv Monday, February 14, 2011, 9:41 AM