1299 Promenade Pl - Heating Test Record
HEATING TEST RECORD V'fU Address k Zf'1 P 2C4%A e r> O ~Z Apt. # Floor # City ip, Occupant C. v v+~s Owner t c- 6k 1 Date Installed 1 7, , - Sold By lM I%Qt4(~j~ 1M.t-:-,C.64- Installed By VAPf %E7r VA&C,64 Electrical By WO O " a.-'t vkaM% J Gas Line By D Type of Heat GA FA HW Space Heater Unit Heater Rooftop GAS DESIGN Make Model %.A LAC. `Z 0 t5'-{ 2 ~ p► F DO e VVk r (-W Serial l C t Z t 3 c3 Input ZS ©d a CONVERSION BURNER Make of Burner Model M l Max. BTU Rating Make of Furnace Model CONTROLS Thermostat Make/Model CCZ~'`~ Heat Plug Gas Valve Make tod A t-ie Qo6ta ms Model '-75(&A5`4 Limit Make/Model ' Limit Setting iC~0 Fan Setting "fl,MiOr> Pilot Type 6-1-AgW-1 tzex; V~, Pilot Make +d LQC lwy v-~- -Tct,ua Pilot Model Pilot Timing "L O Vi e, L.W. Cut Off Vent Size Kind of Liner Size None: Draft Hood Regulator Make/Model- " ~Z Filter Size/Number 'k k koyc 2b Chimney Location Inside Outside Chimney Construction Smoke Bomb Wiring Draft Test Tag_ ~C. Door Pressure Lighting Instructions Manifold Pressure 3 -%;Z Input CFHT-Sa ooy Stack Temperature 2-3 Percent C02 '3-8B Percent 02 0-t Percent CO 0 Date Tested I?-- i -1 1 Company Testing W Von- Vc~~ 1Me6" Name of Tester t) C i~t>iZL~ License # MARKET MECHANICAL 8701 Wyoming Ave North Brooklyn Park, MN 55445 testO 327-1 V1.11 016757e3/USA 12/13/2011 12:39:28 Fuel Nat Gas CO2 max 11.7 Flue gas 234.3 OF T stack 3.88 : CO2 81.0 % EFF 178.7 % ExAir 14.0 % Oxygen 67 ppm CO 199 ppm CO AirFree inHZO Draft 40.8 OF Ambient temp 46.4 OF Instrum temp OF Diff, temp. inHZO Diff. Press 0 PPm CO Ambient i HEATING TEST RECORD Address t -L-Ot ":~i PRO Mt~u Ale D tL Apt. # Floor # City §~~k-> Occupant Owner C X~tkk Date Installed 1-L - -1 --~t Sold By_~M Installed By M r>TLV".;a 't Electrical By -VM lUn.»1 Z U l~l~' Gas Line By Type of Heat GA FA HW Space Heater Unit Heater Rooftop` GAS DESIGN Make Tom- y Model k-Aca;- Serial a N 4~ t 17-1 Input -V. O t 000 CONVERSION BURNER Make of Burner Model Max. BTU Rating_ Make of Furnace Model CONTROLS Thermostat Make/Model V;L-M Pf e Heat Plug Gas Valve Make 1,) A t-Te n a b Model 3(aD LI-4 Limit Make/Model ° Txzry,* , Limit Setting 19 O Fan Setting -T t vueoo > Pilot Type 'rtCTt S t C . Pilot Make LJ0V ''tvv Pilot Model Pilot Timing 2 y-4 %v L.W. Cut Off Vent Size Kind of Liner Size None Draft Hood Regulator Make/Model -5Z'~ - Filter Size/Number I toyz Z- llaZ.Z Chimney Location Inside Outside Chimney Construction Smoke Bomb Wiring Draft Test Tag 0~- Door Pressure Lighting' Instructions Manifold Pressure -Z4 O Input CFH ZS®t 0 Stack Temperature Percent C02 ' Percent 02 t Percent CO Date Tested iZ- Ira°~i I Company Testing OA VR Name of Tester S~ey-F-6?'L License# MARKET MECHANICAL 8701 Wyoming Ave North Brooklyn Park, MN 55445 G .est, 3V-1 X11.11 01679763/USA 1Z/13/2011 13:06:09 Fuel Nat Gas CO2 max 11.7 % Flue gas 452.5 OF T stack 3.01 % C02 81.9 % EFF 41.9 % ExAir 7.1 % Oxygen 2 PPm CO 3 PPM CO AirFree inHZO Draft 39.6 °F Ambient temp 43.7 °F Instrum temp OF Diff. temp. inH20 Diff. Press 0 Ppm CO Ambient HEATING TEST RECORD Address LZei'q ?r?0ta teQQ0 e 0 Apt. # Floor # City EPC-o ' Occupant L,u%-v > 5 Owner L irk i bate Installed I 'L 1-- 1 Sold By iAA0qj4e-T Installed By KA %PIRLe Electrical By AA It7 u~ ~zT Gas Line By p-VUk!VLC Type of Heat GA FA HW Space Heater Unit Heater Rooftop oC GAS DESIGN Make Model %-A GTE e i C- 4 ` P 5 C- Serial i 1 w~ t t>_1-1 $ ID Input 2. 4 o CONVERSION BURNER Make of Burner Model Max. BTU Rating Make of Furnace Model CONTROLS Thermostat Make/Model y ,g_,V~-S L,%E Heat Plug Gas Valve Make Tz c>tae n S Model Limit Make/Model ~ e Limit Setting b Fan Setting i vu ka,7 Pilot Type VA s y,z -vac Pilot Make TTLVa~+~ l vt'rz-tcx-s pilot Model '7_3't t Pilot Timing tat rlJ L.W. Cut Off Vent Size- Kind of Liner Size None Draft Hood Regulator Make/Model 3Z~ S Filter Size/Number-4 l b t Zv Y- z l b it 2 I:. Chimney Location Inside Outside Chimney Construction Smoke Bomb Wiring Draft Test Tag_ Door Pressure Lighting Instructions Manifold Pressure - " Input CFH ZSO % O~t~ Stack Temperature f-'k Percent C02 -1 Percent 02 (o Percent CO 0 Date Tested %L,- i3'r Company Testing 1M 1=~ R 1~ % i~ C Name of Tester License # MARKET MECHANICAL 8701 Wyoming Ave North Brooklyn Park, MN 55445 testa 327-1 V1.11 01679763/USA j 12/13/2011 12:54:29 Fue1 Nat Gas C02 max 11.7 Flue gas 418.5 °F T stack 7.35 % COE 81.3 % EFF 43.8 'r. Exair 6.9 % Oxygen 2 ppm CO 3 ppm CO AirFree inH2O Draft 39.6 °F Ambient temp 44.8 °F Instrum temp °F Ditf. temp. inH20 Diff. Press 0 ppm CO Ambient i