Loading...
3613 Woodland Tr - Ltrs. re: Wood Trusses Permit#102029 i _ 203 LITTLE CANADA ROAD SUITE 280 SAINT PAUL MINNESOTA 55117 TEL: 651-490-9266 FAX: 651-490-9265 /PROFESSIONAL ENGINEERING CONSULTANTS INCORPORATED December 6, 2011 Lance Abrahamson Residential Remodelers 8516 Birch Blvd. Inver Grove Heights, MN 55076 Subj: Structural Alterations ! f '0513 'T 1~~ticJ f Eagan, nesotca P1=C Dear Lance: This letter concerns our structural recommendations to alter wood trusses in the dwelling. We understand you plan to increase the size of the second level bedroom on the left side of the dwelling. The alteration plan is to extend the left side. This plan will require changing the roof line. The change will include removing several portions of the roof trusses, extending the front slope of the roof by hand framing and hand framing the back slope of the roof. The front portion of the roof trusses to their existing peak will remain in place and the remainder will be removed for the alterations. On November 30, 2011, you requested our services to make on-site observations of the trusses and to provide structural recommendations for the remaining truss sections. On December 1, 2011, we made observations at the dwelling. We observed the trusses that will be altered have a king post cord at the center bearing on the top of the bearing wall. It is our opinion the alterations will require reinforcing the connection plates with gussets where connecting truss cords will be removed. We recommend gluing and screwing a thick plywood gusset on one side of each connection where truss cords will be removed. The gussets should extend approximately 18" along each remaining cord in the connection. Use construction grade adhesive to glue the gussets to the remaining cord sections. Respectfully, Professional Engineering C sultants, Inc. Un F. Gislason, Jr. P.E. Fa r 203 LITTLE CANADA ROAD SUITE 280 SAINT PAUL MINNESOTA 55117 TEL: 651-490-9266 FAX: 651-490-9265 /PROFESSIONAL ENGINEERING CONSULTANTS INCORPORATED December 7, 2011 Lance Abrahamson Residential Remodelers 8516 Birch Blvd. Inver Grove Heights, MN 55076 Subj: Structural Alterations 3613 Woodland Trail Eagan, Minnesota PEC #9280 Dear Mr. Abrahamson: This letter concerns our structural evaluation of bathroom floor trusses notched for the installation of a shower. We understand you cut 2" deep notches in the top of 2 X 10, Southern Yellow Pine visually graded #2 floor joists for the installation. The floor joists are at 16" centers and have a 15' -6" clear span and an 18" cantilevered overhang. You added supplemental reinforcement to the notched sections by gluing and nailing 2 X 8 lumber to the notched sections. On December 6, 2011, you requested our services to evaluate the design stresses on the notched floor sections. You furnished dimensions and a photograph of the work area. It is our opinion notching the floor joists and adding reinforcement will meet design loading requirements. We calculated bending stresses for design loading for a live load of 40 pounds per square foot and 10 pounds per square foot dead load on 2 X 8 joists spanning 15' -6" , the remaining cross-sections of the notched 2 X 10' s. The calculated design bending stresses were slightly less than the allowable bending stress. This is without adding the supplemental reinforcement. Respectfully, ,p 6 - , Pr fessional Engineering Consultants, Inc. 77 3j )-o fin F. Gislason, Jr. P.E.