Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4894 Steeplechase Ct
City of Epp 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675 -5675 Fax: (651) 675 -5694 6t--/oct re___/0-731-14) l Qt MCI vJ W SI(C(9- Lor 3 t Use BLUE or BLACK Ink For Office Use / //, L�/� Permit #: v 3 7 Permit Fee: Date Received: Staff: 2012 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 411 ' Pt-- Site Address: 469 rjf'1°-.t`- IOV:Gtd4 IE- (ODA -l' Unit #: RESIDENT / OWNER TYPE OF WORK Address / City / Zip: 1 `I ` � 0 SP1E -F-rt ,c Mt le__ is .)i /AO Mr► •-) J J J v.. 2.. Applicant is: Owner X Contractor Description of work: N� - '4 - V. 1 1 ?\) . % b.h.IoM Ir g%),...1 o , 4 \ Construction Cost: /9s, S`la b. o0 Company: T0k.■. anard E." s , 1.J `. State: M' Zip: SS / Z >i License #: r 3 o Multi - Family Building: (Yes )( / No ) Contact: IZ,1As LC; rrj2,1 u Phone: D/�h' .51- par- Vlow U .. -7111-2.61 A) IA- Lead Certificate #: CONTRACTOR If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes ?CNo If yes, date and address of master plan: Licensed Plumber: SP _ j f3 J NO Phone: Mechanical Contractor: (Ay s'J. 1.4)E%-1 ) 1 JA.L. Phone: Sewer & Water Contractor: NM, , EAC.4IIrrr4 - / j f n r WA-re"- Phone: '}e3 '4-'%-'�3 Sea (o/t- gt 6S10- tor/ - `l rya- l3 f r NOTE: Plans and supporting documents that you submit are considered to be public inform Portions o the information may be classified as non - public if you provide specific reasons that would perm!t the City to conclude that the are trade. secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454 -0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. ( x I �-A C,sa /}-nJ k ;Fr /241 b£ 6 Ibh?s., x Applicant's Printed Name Applicant's igiiature Page 1 of 3 SUB TYPES Foundation Single Family Multi 01 of 'l Plex Accessory Building WORK TYPES 1, New Addition Alteration Replace Retaining Wall DESCRIPTION Valuation Plan Review (25 %_ 100% ) Census Code # of Units # of Buildings Type of Construction 5 REQUIRED INSPECTIONS Footings (New Building) Footings (Deck) Footings (Addition) Foundation Drain Tile Roof: _ Ice & Water _ Final \ELFraming Fireplace: C tsRough In `Air Test Ni Final Insulation Sheathing Sheetrock Reviewed By: RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S &W Permit & Surcharge Treatment Plant Copies Fireplace Garage Deck Lower Level Interior Improvement Move Building Fire Repair Repair TOTAL DO NOT WRITE BELOW THIS LINE K 6yLIC) q S 1 f - fC , e-rrie Porch (3- Season) Porch (4- Season) _ Exterior Alteration (Single Family) Porch (Screen /Gazebo /Pergola) _ Exterior Alteration (Multi) Pool Miscellaneous Occupancy Code Edition Zoning Stories Square Feet Length Width Siding Reroof Windows Egress Window - Water Damage *Demolition of entire building – give PCA handout to applicant ro Building Inspector Storm Damage Demolish Building* _ Demolish Interior Demolish Foundation MCES System SAC Units City Water Booster Pump _ PRV Fire Sprinklers Meter Size: Final / C.O. Required Final / No C.O. Required HVAC _ Gas Service Test Gas Line Air Test Other: Pool: Footings Air Gas Tests Final Siding: Stucco Lathj Stone La _ Brick Windows Retaining Wall: — Footings _ Backfill _ Final Radon Control Erosion Control 5yr (Awr 1 X)L,s - vim 27,0"/ tvlf)"A^' I03b y9 tc( 2w0 1 X9A 23 = I I , 32-►,N/ 0-1,4 SIG x3��9 X Li us— i q L6, y11 Li 170 Page 2 of 3 zs' fSi.s1 Date: 7/6/2012 Revision Date: 7/6/2012 New Construction Site Information Address 1: Toll Brothers Project #: Steeplechase of Eagan Address 2: 4894 Steeplechase Court Lot: #31 Block: City: Eagan County: Subdivision: Application Information Business Name: Ray N. Welter Heating MN Contractor License #: Contact Person: Joe Office Ph: 612 - 825 -6867 Fax: Cell Ph: Address 1: 4637 Chicago Ave. So. City: Minneapols State: MN. Zip Code: 55407 House Details Square Feet: 4701 sq. ft. Avg. Ceiling Ht: 10 ft. Number of Bedrooms: 3 Ventilation : Exhaust Total Ventilation Capacity : 206 cfm. Minimum Continuous Ventilation :60cfm. Continuous Ventilation Provided: Exhaust: 60 cfm Intermittent ventilation satisfied by OTHER exhuast appliance. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace /Boiler: Direct Vent/Sealed Combustion Input BTUs: 80,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 400 Make -Up Air No Make -Up Air Required by Code Combustion Air Minimum Combustion Air Requirements Met. Applicant Name (print):I,J &-% Signature /Datee Code Official (print): Signature /Dat © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 ROOM NAME Area (ft') Htg load (Btuh) Clg Toad (Btuh) Htg AVF (cfm) CIg AVF (cfm) lot 31 basement 1780 19041 5410 273 240 lot 31 upper 1569 15233 1104 218 49 lot 31 main 1605 18782 10629 269 471 lot 31 all 4954 53056 17142 760 760 Other equip loads 0 0 Equip. @ 0.93 RSM 15908 Latent cooling 1417 T/1TAI es A"LA c/]n,r∎ A 7nL -inn Cn -- wrightsoft® Load Short Form lot 3/ all Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612 - 825 -6867 Fax: 612 - 825 -2303 Project Information For: Design Information Outside db ( °F) Inside db ( °F) Design TD ( °F) Daily range Inside humidity ( %) Moisture difference (gr /Ib) Htg -15 70 85 30 32 HEATING EQUIPMENT Make Trane Trade Trane Model TUC1B 080A9421A* GAMA I D 164848 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 80000 Btuh 74000 Btuh 91 °F 760 cfm 0.014 cfm /Btuh 0 in H2O CIg 88 75 13 M 50 28 wrightsoft Right - Suite® Universal 7.1.17 RSU11308 ACCK W: \Wrightsoft HVAC \Toll 4 Plex.rup Calc = MJ8 Orientation = SW Web: www.welterheating.com Method Construction quality Fireplaces Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Infiltration Printout certified byACCA to meet all requirements of Manual J 8th Ed. Job: Toll 4 Plex Date: By: Simplified Tight 3 (Average) COOLING EQUIPMENT Make Trane Trade XB13 Cond 4TTB3024A1 Coil 4TXFH018AS3 + *UY060R9V3 ARI ref no. 1052416 Efficiency 11.2 EER, 13.3 SEER 15960 Btuh 6840 Btuh 22800 Btuh 760 cfm 0.044 cfm /Btuh 0 in H2O 0.92 2012- Jun - 2613:09:20 Page 4 T f b w 0 E Pri a 4 -c. cp 6 6 6 4 a 2 Pik S 8 n CD 0 0 CD a ij 3 u 0 rr 0 0 ixt ID R fD DJ fD m 0 2 o q 1 td 0 6 DJ L 1 e st } G i w 0 a 4 w 0 N L N b G 4 w G 7 8 2 c Iv z Q. I R. rD G 3 0 3 s 0 0. D 0 0 rr 0 cD 0. (l1 CD :' I1 0 0 -t f 21 so t 1 -P 0 L 0) a 1 0 • 0) rh -is to Lfi-e-s • MS. S\ tki C t t-- T r fs I I Or-- Srp•J(... 4 J ill 1 ) 6 4 - 1 4 411.6 -KX- -- SO A-r LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: kJ 1 , ll K �j 's I t DATE OF SURVEY: 7/ia/Z. LATEST REVISION: a) a a as U Y a -a O Z Q DOCUMENT STANDARDS 4 0 0 • Registered Land Surveyor signature and company ❑ ❑ • Building Permit Applicant ❑ ❑ • Legal description 00 • Address ,I21' ❑ ❑ • North arrow and scale ❑ 0 • House type (rambler, walkout, split w /o, split entry, lookout, etc.) y 0 ❑ • Directional drainage arrows with slope /gradient % ❑ ❑ • Proposed /existing sewer and water services & invert elevation 'go ❑ • Street name p 0 ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.) 7 0 0 • Lot Square Footage 4 0 ❑ • Lot Coverage ELEVATIONS Existing 4 0 0 • Property corners 4 ❑ 0 • Top of curb at the driveway and property line extensions ❑ jj 0 • Elevations of any existing adjacent homes A 0 ❑ • Adequate footing depth of structures due to adjacent utility trenches y' ❑ ❑ • Waterways (pond, stream, etc.) Proposed ,j' ❑ ❑ • Garage floor ,'j ❑ 0 • Basement floor ❑ ❑ • Lowest exposed elevation (walkout/window) , 0 ❑ • Property corners ,0 0 ❑ • Front and rear of home at the foundation PONDING AREA (if applicable) C / y0 0 • Easement line / ❑ 0 • NWL iy 0 0 • HWL "( ❑ ❑ • Pond # designation 0 ❑ • Emergency Overflow Elevation ❑ • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ❑ ❑ • Lot lines /Bearings & dimensions �r ' ❑ 0 • Right -of -way and street width (to back of curb) ❑ ❑ • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) /i 0 0 • Show dll easements of record and any City utilities within those easements ❑ 0 • Setbacks of proposed structure and sideyard setback of adjacent existing structures g ❑ 0 • Retaining wall requirements: /4 Reviewed By: / /�!�� Date Z� / G: /FORMS /Building Permit Application Rev. 11 -26 -04 0 Certificate of Survey 4890, 4892, 4894, 4896 STEEPLECHASE COURT tcuired T NORTH SCALE IN FEET BENCH MARK TNH ELEV= 961.08 30 OF BENCHMARK Top Nut Hydrant Lot 9, Block 8, Steeplechase — Northwest side of Steeplechase Court, Elevation = 961.08 feet (NGVD 1988) 9 Henry D. Nel AREA Lot 9, Block 8 Area Total Condo area 20% Max. Coverage Foundation Lot 3, Block 6 Foundation Lot 1, Block 7 Foundation Lot 2, Block 7 Foundation Lot 1, Block 8 Foundation Lot 2, Block 8 Foundation Lot 3, Block 8 Foundation Lot 4, Block 8 Foundation Lot 5, Block 8 Foundation Lot 7, Block 8 Foundation Lot 9, Block 8 Total Foundation coverage Remaining coverage Available r'A AA‘ S r i .' 4-444 EAGAN ENGINEERING DEPT. s n o� o b Pe looa �wot o = 20,653 sq. ft. = 703,324 sq. ft. = 140,665 sq. ft. = 9073 sq. ft. = 9074 sq. ft. = 7106 sq. ft. = 6676 sq. ft. = 6815 sq. ft. = 6709 sq. ft. = 6709 sq. ft. = 9072 sq. ft. = 9093 sq. ft. = 8,862 sq. ft. = 79,189 sq. ft. = 61,476 sq. ft. CITY OF EAGAN Lot 9, Block 8 STEEPLECHASE OF EAGAN Subject to easements of record, if any. on, MN Lice se No. 17255 Date I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed La d Surveyor under the laws of the State of Minnesota. July 12, 2012 TOLL BROTHERS 1400 Corporate Center Curve Eagan, MN 55121 LEGEND Iron monument found Offset iron Drainage & Utility Easement Existing Elevation Proposed elevation from grade or development plan Drainage Direction Retaining Wall Bearings shown are PROPOSED ELEVATIONS 4890 & 4892 964.1 — 840 _ — 842— = — < —= — «— O �a = ▪ = • = • = assumed Garage floor elev. = Top of block elev. = 964.4 Lowest floor elev. = 955.8 elevation elevation PROPOSED ELEVATIONS 4894 Garage floor elev. = 961.1 Top of block elev. = 961.4 Lowest floor elev. = 952.8 PROPOSED ELEVATIONS 4896 Garage floor Top of block Lowest floor RLJ( ( KUUSISTO LTD ) „42 TAE MR CONTROL 94 942 - 940-- LP 7.4 NWL =938.3 HWL =941.3 Prop. San. & Water Inv. elev. = 944.8 WO House Minimum lowest floor = 952.8 (4894 & 4896) = 955.8 (4890 & 4892) Prop. 10' contours from grading plan Prop. 2' contours from grading plan Existing sanitary sewer Existing storm sewer Existing water Sanitary manhole Gate valve Hydrant Flared End Section Catch Basin elev. = 959.6 elev. = 961.4 elev. = 952.8 DRAWN: SCA CHECKED: HDN Drawing File: 700 \718— L9— B8.DWG Project No. 2006 -408 -L Minot, ND. Minnetonka, MN. Phone: (952) 933 -0972 Fax: (952) 933 -1153 �sl IBbe www. rlk- kuusisto.com 6110 Blue Circle Dr. • Suite #100 • Minnetonka, MN. 55343 Jul 12, 2012 8: 55am Use BLUE or BLACK Ink For Office Use 44). Permit#: � ✓ / J City of Eaaali Permit Fee: PI 3830 Pilot Knob Road •Eagan MN 55122 Date Received: r II' f Phone: (651)675-5675 Staff: Fax: (651)675-5694 2017 RESIDENTIAL BUILDING feepBUILDING PERMIT APPLICATION Date: 5 11:511/6 _`7 Site Address: �7 l s e Ci; Unit#: Name: I-7/C S e�P/ Phone: (? iZ) 67O-9 Z'/ 3 Reslltl�n J� ` OW er Address/City/Zip: -G j g z-/ he se/o/GGrte,s . N// SS/z2 3414- '41 Applicant is: >c' Owner Contractor Description of work: /1;7%7;64 b s e ry i-2 -Type Of Wori 1 t Construction Cost: Multi-Family Building:(Yes 2—/No ) Company: Contact: Address: City: Contractor(if , State: Zip: Phone: Email: t License#: Lead Certificate#: If the project is exempt from lead certification, please explain why: �`ZJl COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes X No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and s pportil documents at ou a l3 a id i x e ., lic in • P ;entior the informa .may be classified as non public P provide specific reasons that would a _. p conclifde;that they are trade secrets x. „z ew CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. x Applicant's Printed Name Applicant's Signatur. Page 1 of 3 �Cy �j- C.1 NOT WRITE BELOW THIS LINE 7(-11 5-7 S'� SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration (Single Family) Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration (Multi) Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex )(Lower Level Pool _ Accessory Building t WORK TYPES New Interior Improvement _ Siding Demolish Building* Addition _ Move Building _ Reroof Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation Replace Repair Egress Window Water Damage Retaining Wall *Demolition of entire building—give PCA handout to applicant DESCRIPTION Valuation 9, c1i22f2 0 Occupancy 4,,kb 3 MCES System Plan Review Code Edition yl, 4.) 0I SAC Units (25% 100%') Zoning �` (0 City Water Census Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length Fire Suppression Required Type of Construction Width REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final/C.O. Required Footings (Addition) Final/No C.O. Required Foundation Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test Roof: _Ice &Water Final Pool: Footings Air/Gas Tests Final fit, Framing ,30 Minutes 1 Hour Drain Tile 1` Fireplace: _Rough In Air Test Final Siding: _Stucco Lath _Stone Lath Brick_EFIS X. Insulation Windows Sheathing Retaining Wall: _Footings Backfill Final Sheetrock Radon Control Fire Walls x Fire Suppression: ' Rough In Final Braced Walls Erosion Control 7 Shower Pan Other: Reviewed By: -1/' , Building Inspector RESIDENTIAL FEES Base Fee Surcharge t,- Plan Review ' MCES SAC City SAC Utility Connection Charge S&W Permit&Surcharge ( U X ''' )(61-9D Treatment Plant 2 9 Copies TOTAL Page 2 of 3 PERMIT City of Eagan Permit Type:Building Permit Number:EA179772 Date Issued:10/19/2022 Permit Category:ePermit Site Address: 4894 Steeplechase Ct Lot:Block: Addition: Steeplechase Of Eagan PID:10-72540-10-031 Use: Description: Sub Type:Reroof Work Type:Replace Description:Includes Skylight Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. If water damage is encountered, please call (651) 675-5675 to schedule a site visit to verify the extent of the damage. Any repairs must be inspected prior to covering. The inspector will determine if an additional permit will be required to repair the water damage. Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Eric Todd Schaefer 4894 Steeplechase Ct Eagan MN 55122 Parkway Custom Construction Llc 1303 S Frontage Rd Suite 199 Hastings MN 55033 (651) 480-3797 Applicant/Permitee: Signature Issued By: Signature