3578 Sawgrass Tr E - Memo re: Structural Engineering Braced Wall MEMORANDUM I hereby certify that this plan, specification or report To: Lennar Corporation was prepared by me or under my direct supervision Re: Front Den Braced Wall Review and that I am a duly licensed professional engineer ota . 1622 - Kingsfield "B2" under the laws of :V7~~7 3578 Saw crass Trail East Eagan, MN Nick Hanson Stonehaven Preserves Date: 8-22-12 Project No. 2.0222 Minnesota Registration No. 46665 III ICI The purpose of this memorandum is to report the findings of a structural engineering braced wall review of the revised front Den wall to the 1622 -Kinsfield "B2" -plan proposed in the Stonehaven Preserves at the address above. The Hanson Group has reviewed the proposed modification and the following is noted: 1. The front garage wall braced portal frame detail provided by Ulteig Engineers should be referenced for bracing at the front garage wall. 2. The attached partial plan of the modified front Den wall provided by Lennar is attached below for reference. The modification is an 8'-4" wide window in place of a 5/0x6/0 window specified. A structural engineering review was conducted of the proposed modified front wall Den window. The modification outlined above and in the attached partial plans will not affect the structural integrity of the Main Windforce Resisting System as laid out by Ulteig Engineers provided the attached shear wall detail is constructed to brace the front wall. After our review of the above information and associated documentation, it is our professional engineering opinion that the proposed modification will not affect the braced wall layouts previously provided upon construction of the shear wall detail. This document applies to the review of the front Den wall modification of the braced wall drawings provided by Ulteig Engineers. All other aspects of the project are outside the scope of this document. All construction is to be in accordance with this document, standard industry practice, and the requirements of the Code. Sincerely, The Hanson Group ROOF TRUSSES Project Number: 2.0222 FASTENED TO AUG 2 2 M Date: 8-22-12 PLATES w/ (3) 8d Sheets: 1 of 1 TOENAILS 3407 Kilmer Lane North, Sulte4 2x4 BLOCKING Plymouth, MN 55441 Tel 612-708-3572 BETWEEN www.hansongroupmn.com TRUSSES NAILED TO TOP PLATES w/ (3) 8d NAILS EACH 2'-11 • 1 PROVIDE FASTENING OF ABOVE •I•!• FRAMING AS SHOWN ABOVE ` CORNER FRAMING TO HAVE (2) FULL HT STUD i~ FASTENED TO HOLDOWN HATCHED AREA INDICATES ~/16" MIN. PLYWOOD/OSB EXTERIOR I SHEATHING FASTENED TO • ' STUDS w/ 8d NAILS @ 3" O.C. AT PANEL EDGES & @ 12" O.C. AT INTERIOR SUPPORTS Q ~I I' _ r a) PROVIDE (2) 2x6 STUDS I AT END OF SHEARWALL USP STAD14RJ HOLDOWN r' I ANCHOR ACROSS FLOOR SYSTEM •%'f FASTENED TO DOUBLE STUDS w/ }f. { MIN. (38) 16d SINKERS (REFER TO J f ULTEIG DRAWINGS FOR `f y POST INSTALLED HOEDOWN OPTION) '/f{f ff ' a PROVIDE 2x6 BLOCKING IN ® FLOOR SYSTEM AS REQ'D 'f 1 FRAMING DETAIL S1 RAISED SHEARWALL Lennar Corporation Hanson Group Project: 2.0222 v . August 22, 2012 Page 2 Braced Wall Section in Accordance with R602.10.3 Method 5-Gypsum Board LFEi Gyp Braced Wall 5 FEET q* FOPWL .e 3 E New Shear wall M a i ; • .fit 1! NAM I - *-W W I T- Portal Framing Braced Wall by Ulteig Illustration 1: Proposed Modification of Front Den Wall by Lennar R602.10.3 Braced wall panel construction methods. The construction of braced wall panels shall be in accordance with one of the following methods: 5. Gypsum board with minimum %2-inch (13 mm) thickness placed on studs spaced a maximum of 24 inches (610 mm) on center and fastened at 7 inches (178 mm) on center with the size nails specified in Table R602.3(1) for sheathing and Table R702.3.5 for interior gypsum board.