Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
3225 Denmark Ave - Final Insp Memo
e~o City of E TO: Dale Schoeppner, Building Inspections Scott Peterson, Building Inspections , "Craig Novaczyk or Mike Lence, Building Inspections Mike Ridley, Planning Carol Tumini, Utility Billing Dale Wegleitner, Fire Department Tom Colbert, Engineering John Gorder, Engineering Leon Weiland, Engineering Tim Pahr, Engineering Paul Olson, Maintenance Tom Struve, Maintenance Eric Macbeth, Maintenance Mark Anderson, Electrical Inspector FROM: Terry Zelenka, Building Inspector DATE: March 10, 2009 SUBJECT: Final Inspection for 3225 Denmark Ave (Postal Credit,,Unlony The Protective Inspections Division will be performing a final inspection at the above referenced property on March 24, 2009. If you have cause for not granting the Certificate of Occupancy, please submit a "hold request" to my attention. The person/department requesting a hold is responsible for notifying and resolving problems with the affected parties. CD/Bldg Insp//Forms/Comm Bldg//Final Inspection For_ COLLABORATIVE [)CS10-1IGI' 3ttp,inc, . August I, 2008 Architecture Engineering Interiors Planning Craig Novaczyk, Senior Building Inspector City of Eagan 3830 Pilot Knob Road Eagan, MN 55122-1810 Re: Postal Credit Union - 3225 Denmark Avenue-Plan Review Comments Dear Craig: We have received a copy of your letter to Andrew Naughton of James Steele Construction, dated July 18, 2008, in regards to some comments you had from the review of the Postal Credit Union plans. I would like to take this opportunity to address your comments. 1. Room 110 (Break Room) to comply with Section 804 through 804.6.6 of the ICC/ANSI Al 17.1 - 2003. Attached is a copy of Addendum #1. We have addressed the height and clearance issues in this addendum. 2. Water closet flush controls shall comply with Section 604.6 of the ICC/ANSI Al 17.1 - 2003. Attached is a cutsheet of the specified flush valve. The cutsheet indicates that flush valve is ADA compliant. Specification Section 22 4000 "Plumbing Fixtures", paragraph 3. 1, item I states "Install flushometer valves for accessible water closets and urinals with handle mounted of wide side of compartment." 3. The accessible aisle adjacent to the accessible parking space shall be marked with the designation "No Parking". See attached Addendum #l. 4. For sign permits please contact Mary Granley at (651) 675-5683. For information only. The owner or the contractor will be providing the building, monument and pylon signage through their sign vendor. We will pass along this information to the sign vendor. In addition, we received a copy of your letter dated July 17, 2008 requesting that we submit Energy Calculations, Illumination Budget Calculation Form, information on the requirements for the Emergency Response Site Plan and the Fire Protection System Plan Review form. Attached are the completed Energy Calculations, Illumination Budget Calculation Form and the Fire Protection System Plan Review Form. The Emergency Response Site Plan was submitted to Eric Slettedahl with the City of Eagan. He reviewed the submitted plan and informed us that the plan met the city requirements. I believe that you were copied on his approval of the plan. 100 Portland Avenue South, Suite 100 Minneapolis, Minnesota 55401 t612.332.3654 f332.3626 1tNrili ,iivo t r{irni, t-mlal Oopmh!miy Ernployer www.collaborativedesigngroup.com I hope that these responses provide the information you need. If you have any other questions or comments please let me know. Very truly yours, C911aborative Design Group, inc. Cu `v~ C . David Witt Project Manager Cc: Andrew Naughton -James Steele Construction Enclosures SEE SCHEDULE GL-5 CL ui d w U cl) W w 6 1 FRAME TYPE 6 5/A001. D D 1. SCALE: 1/4"= V-0" POSTAL CREDIT DATE 7/22/08 ADD 0 SCALE .1 UNION BRANCH 1/4" =1'-0" . 1 BID PACKAGE 112 DR. BY CK BY JOB NO. ~m ADDENDUM #1 BNT 08014.00 ® COLLABORAWE DESIGN GROUP, INC. 2008 p d > "NO PARKING" d LETTERING p d d p (D z O p p z n/ D ~ . p - .a A - - p d 1 SITE PLAN "NO PARKING" LETERING DD1 SCALE: 1/4"= V-0" ice POSTAL CREDIT DATE 7/2y08 Roa ADD UNION BRANCH SCALE 1/4"= V-0" 1.2 BID PACKAGE 42 DR. BY CK BY JOB NO. ",no ADDENDUM #1 BNT 08014.00 COLLABORATIVE DESIGN GROUP, INC. 2008 FIREPLACE WALL AND 2' 9" CHASE WALL TO i / CROOF HASE DRAIN 3 BE WALL TYPE 3 SAFETY g~ - CLR INTERIOR 102 I 1 = DIMENSION _ \I 3 I I 3 I 1 WALL TYPES 1/A200 2 ROOF DRAIN CHASE 1/A200 D D 1 . SCALE:.1 /4" = 1'-0" D Dl -SCALE: 1/4"= 1'-0" I- i N 1 GI I ~--I I S 30"x48• 1 R~F CLR ' FLOOR SPACE REAK OOM 110 ' 110A I 30"x48" ' CLR FLOOR 1 SPACE 1106 DW o ' 9B r - - COIN 16 I COUNTER 3 BREAK ROOM CLEARANCES (1/A200) D D 1. SCALE: 1/4"= 1'-0" POSTAL CREDIT DATE 7/22-108 ADD UNION BRANCH SCALE 1/4"= r-0" 1.3 DR. BY CK BY JOB NO. BID PACKAGE #2 M~ ADDENDUM #1 BNT 08014.00 ® COLLABORATIVE DESIGN GROUP, INC. 2008 10'-A.F.F. Q _ x 103 3 GVVB._: 101 10 =0" A f,F. 11 V 0 102 ~ GWB 6'-2" A.F.F. INSTALL SOFFIT OVER BANK EQUIP. AFTER INSTALLATION OF EQUIP. SAFETY DEPOSIT SOFFIT DETAIL REFERENCE 1/A300 D Dl -SCALE: 1/8"= 1'-0" ° a I OPEN c TO I ; ELOW 04 C 33'-0" 113'-4Y4" 16 43 ° M v -v 0 1 LIGHT VE FACE OF SOFFIT 2 CLERESTORY COVE LIGHT DETAIL REFERENCE 4/A300 D D 1. SCALE: 1/8- = 1'-W POSTAL CREDIT DATE 7/22/08 ADD ice SCALE UNION BRANCH 1/8" =1'-0" 1.4 °Gi01P'`` BID PACKAGE #2 DR. BY CK BY JOB NO. ~ADDENDUM #1 BNT 08014.00 0 COLLABORATIVE DESIGN GROUP, INC. 2008 GWB CEILING EL:10'-0" A.F.F. GWB ON 3 MTL STUD FRAMING SOFFIT HEIGHT EL: 6'-2" A.F.F. F - - - - 1 SAFETY DEPOSIT SOFFIT SECTION 15/1430 DD1. SCALE: 1/4"=1'-0" COORDINATE WIDTH & / DEPTH OF COVE w/ LIGHT MANUFACTURER'S X RECOMMENDATIONS COVE LIGHT - SEE ELEC. HD WD TRIM PL-2 VENEER OVER MDF BOARD GWB 3 MTL STUD FRAMING 2 CLERESTORY COVE LIGHT DETAIL 16/A430 ~M.YSCALE: 1/4" = 1'-0" POSTAL CREDIT 7/22/0$ ADD AS NOTED 1.5 UNION BRANCH SCALE BID PACKAGE #2 DR. BY CK BY JOB NO. ADDENDUM #1 BNT 08014.00 ® COLLABORATIVE DESIGN GROUP, INC. 2008 1 3 66 66 PT-4 18" 18 36" 33" I 0 I I I I I PL-1 COUNTER W/ 4" BACKSPLASH CV N PL-2 UPPER AND L - LOWER CABINETS c a ^ iv PL-2 SOLID VERTICAL PANEL TO SUPPORT ANGLE 33" FOR ACCESS PANEL D.W. BY OWNER TO ACCOMODATE 34" HIGH COUNTERTOP 1 ACCESSIBLE COUNTER IN BREAK ROOM 1/A610 D D 1. SCALE: 1/4"= V-0" POSTAL CREDIT DATE 7/22J08 ADD SCALE UNION BRANCH 1/4"= l'-O" 1.6 T~ BID PACKAGE #2 DR. BY CK BY JOB NO. ADDENDUM #1 BNT 08014.00 ® COLLABORATIVE DESIGN GROUP, INC. 2008 CLR -777 77-77 T VJ z O U) P wQ > Q -i PL-2 w/ MELAMINE w INTERIOR, WHT w HARDWARE PULL, SEE SPEC. UNDERCABINET LIGHTS, TYP. z CAULK PERIMETER O U) H wQ Q Lu 2'-0" KITCHEN SINK & > w FAUCET, SEE MECH. w 3/4" PLAM COUNTER & BACKSPLASH WITH 8" 1-1/2" SELF EDGE c~ 2"x2"x1/8" ALUMINUM ANGLE, ANCHOR TO WALL CD 04 PROVIDE ESTUCHEON PLATE PL-2 ON %4" MDF, N REMOVABLE PANEL 1 CABINET SECTION ACCESSIBLE SINK 1/A660 DD1. SCALE: 1"= 1'-0" DATE - Poa POSTAL CREDIT 7/W08 ADD SCALE UNION BRANCH 1 1-0 1.7 BID PACKAGE #2 DR. BY CK BY JOB NO. ADDENDUM #1 BNT 08014.00 ® COLLABORATIVE DESIGN GROUP, INC. 2008 RoyalO Model O Flushometer 00,~ Description Exposed Water Closet Flushometer, for floor mounted or wall hung top spud bowls. + R Flush Cycle ❑ Model 110 Water Saver (3.5 gpf/13.2 Lpf) 141' ❑ Model 111 Low Consumption (1.6 gpf/6.0 Lpf) 110~ Specifications Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer with the following features: " PERMEX" Synthetic Rubber Diaphragm with Dual Filtered Fixed t Bypass " ADA Compliant Metal Oscillating Non-Hold-Open Handle with Triple Seal Handle Packing " 1" 1. PS. Screwdriver Bak-ChekAngle Stop • Free Spinning Vandal Resistant Stop Cap • Adjustable Tailpiece " High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut " Spud Coupling and Flange for 1'/2" Top Spud " Sweat Solder Adapter with Cover Tube and Cast Set Screw Wall Flange " High Copper, Low Zinc Brass Castings for Dezincification Resistance " Non-Hold-Open Handle, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID- Technology " Diaphragm, Handle Packing, Stop Seat and Vacuum Breaker to be molded from PERMEX" Rubber Compound for Chloramine Resistance Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037, ANSI/ASME 112.19.6, and Military Specification V-29193. ® Variations ❑ HL-3 3" Metal Oscillating Push Button on Front of Valve (does not 2114"MIN. meet ADA requirements (57-) - - - - - - f" I.P.S. ❑ TP Trap Primer SUPPLY - ❑ YG Extended Bumper on Angle Stop (for seat with cover) 1 43/4" ❑ YO Bumper on Angle Stop (for open front seat without cover) 0 (12imm) 1 CENTER 121M See Accessories Section of the Sloan catalog for details on these and 11 /2" other Flushometer variations. (292mm) OF FIXTURE " ® Certified in U Pc ® Listed by I.A.P.M.O. This space for Architecl/Engineer approval 7CENTER NEE FIN. FLOOR FIN. WALL , The information contained in this document is subiect to change without notice. LOA. N. Made in the U.S.A. SLOAN VALVE COMPANY • 10500 SEYMOUR AVE. " FRANKLIN PARK, IL. 60131 Royal 110 S.S. - Rev. 1 (12/01) Ph: 1-800-9-VALVE-9 or 1-847-671-4300 " Fax: 1-800-447-8329 or 1-847-671-4380 Copyright © 2001 SLOAN VALVE COMPANY Printed in the U.S.A. http://www.sloanvalve.com City of all Mike Maguire July 17, 2008 MAYOR Paul Bakken Andrew Naughton James Steel Construction 1410 Sylvan Street Cyndee Fields St. Paul, MN 55117 Meg Tilley COUNCIL MEMBERS RE: Postal Credit Union 3225 Denmark Ave Thomas Hedges Dear Andrew: CITY ADMINISTRATOR We have-started our review of the construction documents submitted in pursuit of obtaining a building permit for the above-referenced project. This review is not intended to be an exhaustive and comprehensive report. Unless otherwise noted, all references are to the 2006 I.B.C. It is our goal that this review will help you in complying with the applicable codes and we are, therefore, requesting that the _ following items be addressed: MUNICIPAL CENTER 3830 Pilot Knob Road 1. Set of Energy Calculations. Eagan, MN 55122-1810 2. An Electric Power & Lighting From (Enclosed). 651.675.5000 phone 3. An Emergency Response Site Plan (Example Enclosed). 651.675.5012 fax 4. Fire Protection System Plan Review Information (Form Enclosed). 651.454.8535 TDD If you have any questions concerning this letter, please call me at (651) 675-5683. MAINTENANCE FACILITY Sincerely, 3501 Coachman Point 1/9 Eagan, MN 55122 hn'2z 651.675.5300 phone Craig Novaczyk 651.675.5360 fax Senior Building inspector' 651.454.8535 TDD Encl: Electric Power & Lighting Form Emergency Response Site Plan Example www.cityofeagan.com Fire Protection System Plan Review Cc: David Witt, Collaborative Design Group, 100 Portland Ave S, Suite 100, Minneapolis, MN 55401 THE LONE OAK TREE Dale Schoeppner, Chief Building Official The symbol of strength and growth in our community. i City of Ea~an Mike Maguire July 18, 2008 MAYOR Paul Bakken Andrew Naughton James Steel Construction 1410 Sylvan Street Cyndee Fields St. Paul, MN 55117 Meg Tilley COUNCIL MEMBERS RE: Postal Credit Union 3225 Denmark Ave Thomas Hedges Dear Andrew: CITY ADMINISTRATOR We have started our review of the construction documents submitted in pursuit of obtaining a building permit for the above-referenced project. This review is not intended to be an exhaustive and comprehensive report. Unless otherwise noted, all references are to the 2006 I.B.C. It is our goal that this review will help you in complying with the applicable codes and we are, therefore, requesting that the following items be addressed: MUNICIPAL CENTER 3830 Pilot Knob Road 1. Room 110 (break room) shall comply with Section 804 through 804.6.6 of the Eagan, MN 55122-1810 ICC / ANSI A117.1 - 2003. This section deals with kitchenettes (clearances, 651.675.5000 phone heights, etc.). 651.675.5012 fax 2. Water closet flush controls shall comply with Section 604.6 of the ICC / ANSI 651.454.8535 TDD A117.1 - 2003. 3. The access aisle adjacent to the accessible parking space shall be marked with the designation "No Parking" (Section 502.4.4 of the 1341 MSBC). MAINTENANCE FACILITY 4. For sign permits please contact Mary Granley at (651) 675-5690. 3501 Coachman Point If you have any questions concerning this letter, please call me at (651) 675-5683. Eagan, MN 55122 651.675.5300 phone Sincerely, 651.675.5360 fax 651.454.8535 TDD Craig Novaczyk Senior Building Inspector www.cityofeagan.com Cc: David Witt, Collaborative Design Group, 100 Portland Ave S, Suite 100, Minneapolis, MN 55401 Dale Schoeppner, Chief Building Official THE LONE OAK TREE The symbol of strength and growth in our community. GOl'~.. City of Evan TO: Scott Peterson, Building Inspections #-9 Mike Ridley, Planning Dale Wegleitner, Fire Marshal Tom Colbert, Engineering John Gorder, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Tom Struve, Maintenance Eric Macbeth, Maintenance Gregg Hove, Maintenance Jim McDonald, Police Department Mark Anderson, Electrical Inspector Sarah Brandel, Community Development Peggy Fleck, Clerical Technician FROM: Craig Novaczyk, Senior Building Inspector DATE: July 16, 2008 RE: Plan Review For Building Permit Only: Postal Credit Union Branch (Footing & Foundation Permit Issued) 3225 Denmark Ave The plans are in our plan review section for your review and comment. Please return this form to my attention with your signed comments within 7 days. Please indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper "hold request" form to me. Comments: i Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes ❑ No Landscape Security Required Zoning: ❑ Yes ❑ No Water Quality Dedication Meter Size: ❑ Yes ❑ No Park Dedication ❑ Yes ❑ No Trail Dedication ❑ Yes ❑ No Tree Dedication ❑ Yes ❑ No PRV Required Signature Date CD/Bldg Insp/Forms//Commercial Bldgs Final & Plan Review For Revised