Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4926 Jame Rose Ct
El 4 G~ C~ ' ---Use BLUE or BLACK Ink For Office Usel-~ i Permit V^ l t City/0) Ol Latdll ~5 7 I Permit Fee: ! V~ E~ 7 I 3830 Pilot Knob Road I I 1 Date Received: Eagan MN 55122 I I Phone: (651) 675-5675 Staff. Fax: (651) 675-5694 i G VJ ' 0~s ---f J ESIDENTIAL BUILDING PERMIT APPLICATION 2013 R Date: t l Site Address: 4q a (g J x AAA I IZ GS C- (10 V1 t2T Units: Name: Phone: Resident/ Owner Address / City / Zip: Applicant is: Owner Contractor j Type of Work Description of work: Nj ~ CNLJ le L' C 710 Construction Cost: Mufti-Family Building: (Yes / No Company: V EN N EH ~ r.IM FJ U ~ UD i N~'-l Contact: ~J QE- H I LA k I~ ~~V I I_~1 Address: Soa 0o W Q" ~ 1W T`1 12 p 4,3- ~S ) i Tr q City: P~2 U Contractor State: N Zip: ~~~3- 7 Phone: qf2 ' ~~'✓UbL) License P2(,'1(D1bq 0 ,!Jr Lead Certificate If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan Issued a permit for a similar plan based on a master plan? _Yes No If yes", date and address of master plan: Licensed Plumber.C'«IV ~I I V I TAI 1V 1 Phone: l4'~ ~-'f-t lG' Mechanical Contractor: I')E Al 12. Phone: r,;J0-7 " t,t (P,3- 19 G Sewer & Water Contractor: 0:1? "l Y I .U )"VI V2 I N Phone: (1) 5 1- 2 -~D 7J NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide speed' rc reasons that would permit the City to conclude that the are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.aopherstateonecall.org 1 hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Bu ing a must be completed within 180 days of permit issuance. X 1i,1P 4-A . l I-H 1 L l. x Applicant's Printeai Name Applicant's igna Page 1 of 3 ' DO NOT WRITE BELOW THIS LINE SUB TYPES _ Foundation _ Fireplace _ Porch (3-Season) _ Storm Damage Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family) _ Multi _ Deck _ Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi) _ 01 of Plex _ Lower Level _ Pool Miscellaneous Accessory Building WORK TYPES New _ Interior Improvement _ Siding _ Demolish Building* Addition _ Move Building _ Reroof _ Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation _ Replace _ Repair _ Egress Window _ Water Damage Retaining Wall "Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation !p111 Occupancy MCES System Plan Review Code Edition SAC Units (25°!0_ 100%- Zoning City Water_ Census Code Stories Booster Pump 46o # of Units Square Feet PRV def # of Buildings / Length 11/1_ Fire Sprinklers ,UO Type of Construction Width _7C_ REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) Final / No C.O. Required - Foundation HVAC _ Gas Service Test Gas Line Air Test Drain Tile Other: oof:_& Joe & Water Final Pool -Footings -Air/Gas Tests -Final Framing Siding: -Stucco Lath -Stone Lath -Brick Fireplace: Rough in ,Air Test Final Windows Insulation Retaining Wall: - Footings _ Backfill _ Final Sheathing Radon Control Sheetrodc Erosion Control Reviewed By: , Building Inspector RESIDENTIAL FEES 71 Base Fee Surcharge f ~AV l l g0/ ~U 8`77 Plan Review ® 1lT 77 McES sac City SAC ~r a. / 737 0@ Utility Connection Charge S&W Permit & Surcharge Ati,t4~G ".7 # 3$r /i 7 f?! ~4G ~3 Treatment Plant J n Copies TOTAL /Page 2 of 3 K (~1t of c~ c~T1 City Inspection Dept. Copy City of Ettpn City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development WHISPERING WOODS 14th ADDITION Lot Number 5 Block Number 2 Address 4926 Jamie Rose Ct. Builder Vennehiem Building Corp. Phone Number:-952-890-3000 Contact: Joe Hilla Tree Protection Requirements: X Tree Protection Fencing Installed on Site (Re-set fencing when it gets loose, throughout entire construction process). Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required As Follows: Attachments: ~~Q~((~~ C,(~~Y C~ X Yes (Refer to atta Z ddQjMe aQ s ES•T+ ~ ■ DIVISION No REVIEWED Additional Notes: B T \ DATE - 23 H:\ghove\2012file\treepres\Tree Preservation Plan Whispering Woods W dition Lot 5 Block 2 now n I I 4926 JAMIE ROSE COURT CERTIFICATE OF SURVEY ,a For Wnnehjem Building Corp. \ tel~jL l: PLE-RiIl\ VI ~7r l Y e v V ~ j L; A L_ VJv [71 E7% /C7 K I'I'I 1 A rN t'•% III /1 K I L-L.L-VC_IV1ri ADDII101v i / 1 nT /I 11 S L.v 1 `h ,~o `380 \ / A A K I-r "new low" 102777 0 ✓ 0 2778 2785 10 2782 2783 s s~ F- .03 28/4 2786 V ^k x" ` r .O 8 P 0 0 2789 W 1 p , 8 `2787 8.0 2788 I 0 3. 0 (-0 0 -30.0-- o ' 6 .0 `2783 2~9 2790 F = o C ~s0. X 2808 C W_ / ao 987.3 < 5 p lv ((L;~~ ~ j29 -r < 10 02805 I LU 0o- 2Wr .00 0 2611 O F 1.j 2 01 2606 (D l~~ 2813 2812 10 0 -L 2(8'15 28i 4 ' 00 00 \ 2816 W (n PST Klk/ 74.8 to (.1 ;LEN/ O 6814 + cV 6793 ~_uT v 48.9 fD 'y \ iAi~AK1-r •00 6812 0 5816 Vnvl-\IV I 6813 `i 9 30~ s~~A LOT 5 6794 i LIJ 6798{ 0 MEWL 8440 6797 HWL 946.6 ^ a 6798 PROPOSED HOUSE = 6799 2,321 SQ•FT. OR o 15.5%d OF LOT AREA S ~ DRIVEWAY = 941 SQ. FT. SAN. SERVICE INVERT LOT 7 = 15,016 SQ. FT. PROPOSED ELEV.= 964.2 Scale: 1"=30' Page 2 of 2 James R. Hill, Inc. i_ I o I N ~ I N ':3 co W f' S W 0 m N ° I o W Mu CD Q a' td 'a a) 0 C ~y. W, U U m C C Z 00000001 0 iV 0 O O w 16 °4 E? g 0=1 E 2) !UR _ E Z M\ Z O m p C O V L`s C1' E Cff N LO .C Z r- a) cu ca L2 O Q d O O 8 O > C Cm co IT vvtNNN y00"-'C ID 0 W 0 VO ~ J O C1 yU 2 rn1- F" im a O ~ d C) O o o N o L W 0 a> m o a) 0 cc O 0 CD Z F= ~ 0 N cQ Q OC o 0 p ° L E p E o ao00oa o coo 0 N L O H O V E O a C O fC N N E N Olv g O` 'a O aQ N F- 1- Z F- N O C N N 0¢ N o co 11 p O ~.o ~ cow L O O! N Z N O c O Q O 0 E O ~zI- o000 n* M L- eta Q rn a+ N v ~O 10 V O V- ~ONNCV N E a >CL' N Q C O p to N N N N SO O CD V E N N C A C ON (n v U) O O O O I- 9 O O d " E N E N O W0 E M p 0 m~ - E "a -a rno =N CL CD CL o ~ Q~ _ ❑aL❑o <L in r > N., cn 9- may ❑1. d) C? W a) o ca ER E = N > ~I H Q m v 3 c$ _ O 0 0 ~ U g. Os 0) N N O Q.'a 0 0 'O c ❑ WI- ~Q Uh lnm(AU2(AU ZfY~'m 'fQ;. - 1 2 4926 JAMIE ROSE COURT CERTIFICATE OF SURVEY For Vennehjem Building Corp. PROPERTY DESCRIPTION: Lot 5, Block 2, WHISPERING WOODS FOURTEENTH ADDITION, Dakota County, Minnesota. We hereby certify that this is a true and correct survey of the above described property and that it was performed by me or under my direct supervision and that I am a duly Licensed Surveyor under the laws of the State of Minnesota. That this survey does not purport to show all improvements, easements or encroachments, to the property except as shown thereon. Signed this 8th day of January 2013. J es R. Hill, Inc., B y. Harold C. Peterson, Minnesota L.S. No. 12294 Notes: 1. Building dimensions shown are for horizontal & vertical placement of structure A Denotes set spike only. See architectural plans for building o Denotes set iron monument • Denotes found iron monument & foundation dimensions. x927.6 Denotes existing elevation 2. No specific soils investigation has been (930.0) Denotes proposed elevation completed on this lot by James R. Hill, Inc. Denotes proposed drainage tc Denotes top of curb The suitability of soils to support the specific house proposed is not the responsibility of Bench Mark: 977.14 _TNH-Lots 4 & 5. Block 2 James R. Hill, Inc. or the surveyor. Proposed Garage Floor @ Front= 976.8 3. No specific title search for existence or non- Proposed Garage Top of Block= 977.2 existence of recorded or un-recorded easements Proposed House Top of Block= 977.2 has been conducted by the surveyor as a part Proposed Lowest Floor= 968.5 of this survey. Only easements per the recorded plat are shown. 4. Proposed grades shown were taken from Bearings are on assumed datum the grading &/or development plan prepared by Scale 1'=30' JAMES R. HILL, INC. woo D rn 0 James R. Hill Inc. N M N o < \v -0 D w 0 0 V) / ~ z m PLANNERS / ENGINEERS / SURVEYORS w F O m K: n o o M U) L4 co JK 2500 W. Cnr. P. 42, Sum 120, &w sva MN 55337 PHOE- (952)890-6044 FAX: (952 90-6244 • 4926 JAMIE ROSE COURT CERTIFICATE OF SURVEY For: Vennehjem Building Corp. IA~I II^r-) E-[)INI\n/ nnr\ •1 Maximum SI v v F I I i L_ I\ 1 1 v v v v v v v Z or Retaining Wall Wil 997 ~ Lr- r- r- I _ L _ L_ `V/ L_ I\ v 1_ F l n D D I I_ I L/ IN v Be Required - S L_lJT 1- S ~60 V r-\ f1 0,\ OD e BENCH MARK C9Q ( 2777 \ \ TOP OF SPIKE ~.0 p ` 987.7 ELEV.=980.53 ' ,LSO ✓ 02778 o 2785 10 h r'q S v 0` ✓ rn 2783 v 00 2782 sr A 0 C) 781 0 NO 4 2786 U'' ROPO~NP J,2.03 I 15. 8.06P to Ni N -0 1o rn 789 2787 L cn' p 0 0 6.0_ 2788 C O Ln cv) 0\J 27901 O. 3.0 m.r ;~6.0 2793x' OD - 30.0-- ^ 5.0 2791 I CO 8.0 30.0 0 28086 < w ' • Q:- co ' (968.0) v F 15.00 co ; I w 2807 ° ? 2809 -r 0 '0 (,4 2804 2810 BENCH MARK )1' lg1 TOP OF SPIKE o 2805 > EEV.=965.73 I 7 LIJI 960.1 N'0 2811 LIJ \ NI 28000 9 1 0) 2806 I ° Z 2813 2812 110 cJ- -r- I 2801 2814 0 00 z E"' d 815 00 ~ 2816 $t p\,P / 974.8 r M.H. O ~i w -Nod- ~PSi C~ 6814 a E" 6793 N C H /1T 'K~~ , M.H. %IJ 5r 948.9 Z Ai~A NI -r 6812 t0 nvnl v I 0s 6813 6816 0 \i FES~ 943.0 70O LOT 5 6794C- l1~ LIJ 7\NED 6796 n ~ 0 L1_ Ex. POND 6797 _r- Eriu t~iv~uv~rrctiv Iu~r'T, NWL 944.0 > HWL 946.6 O I PROPOSED HOUSE 679998 C 2,321 SQ.FT. OR I o 15.5% OF LOT AREA DRIVEWAY = 941 SQ. FT. SAN. SERVICE INVERT LOT 7 = 15,016 SQ. FT. PROPOSED ELEV.= 964.2 °j Scale: 1"=30' Page 2 of 2 James R. Hill, Inc. • 4915 JAMIE ROSE COURT CERTIFICATE OF SURVEY For: Vennehjem Building Corp. Lot 5, Block 2 WHISPERING WOODS FOURTEENTH ADDITION Tree Preservation plan Pre House Proposed Post House Development Construction Tree Preservation Construction Const. As-Built Post House Const. As-Built 0 > z 0O w 0 0 > tZ-- w > (n :~F N Z > V) g Z POINT NO. ELEV. TYPE DIA ~ v Of w 0 ~ v w 777 985.1 OAK 17 X X 2778 981.9 CH R Y X X 781 975.8 AK 16 X X 2782 978.4 OAK 16 X X 78 981.1 OAK 16 X X 784 977.5 OAK 9 X X 2785 983.7 CHERRY X X 786 982.8 OAK 18 X X 78 984.2 OAK 13 X X 788 980.6 OAK 9 X 789 978.8 OAK 13 X X 27 0 981. OAK 15 X X 1 979.6 OAK 14 16 X X 279 2793 976.1 AK 19 X X 2800 960.1 OAK 16 X X 2801 963.1 OAK 16 X X 2804 974.9 OAK 1 X X 2805 0 975. AK 1 X X 80 97 .6 OAK 13 16 X X X 0 978.7 OAK 1 X 280 984. OAK 1 X X 280 985.1 OAK 1 13 X X 2810 982.7 OAK 8 11 X X 2 11 979.4 OAK 9 X 12 976.1 OAK 18 X X 2 1 965.7 OAK 1 X X 2814 965. OAK 1 X X 954.1 OAK 10 X X U79 9587AK 15 X X CH RY 6 X X 9 5.7 OAK 1 X X 961. AK 1 X X 963.8 HERRY 6 X X 9585 CHE RY X X 958.3 H Y 6 X X 950. AK 1 X X 681 955. OAK 21 X X 6814 959.7 OAK X X 6816 961.5 OAK 1 X X Preliminary Tree Certification During a site visit on January 9, 2013 all significant trees shown and designated hereon were present and in good health, except as noted in the table above. x 0 The house has been staked. Tree fence will need to be placed outside the dripline of all significant tre be saved. Fut re grading and construction should not have a negative effect on these trees. 0 By. ate: 1 /9 /13 By Date: o Harold C. Peterson, Minnesota L.S. No. 12294 Signature of Owner v, Scale: 1"=30' Page 3 of 3 James R. Hill, Inc. 47 10,9,73-6 RECEIVED New Construction Energy Code Compliance Certificate p Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside D ate Certificate Posted FEB © 19 2013 the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. 2/20/13 Mailing Address of the Dwelling or Dwelling Unit - City "nnehjem 4926 JAMIE ROSE COURT BIERLEIN) Eagan, MN colz~cx~1~ Name of Residential Contractor MN License Number Vennehjem Building Corp. BC108964 THERMAL ENVELOPE RADON SYSTEM o Type: Check All That Apply X Passive (No Fan ) Active( th_Mn and mononicler or o other system monitoring device ) ~ o CC Oa ~ a a Z o R Insulation Location ° - R v w FG ~ ° on on O ~ o o N o a o o E~ Z w w w ac cC Other Please Describe Here Below Entire Slab X Foundation Wall R10 X Interior Perimeter of Slab on Grade X Rim Joist (Foundation) R13.4 X Interior Rim Joist (1st Floor+) 813.4 X Interior Wall R19 X Ceiling, flat R44 X Ceiling, vaulted X Bay Windows or cantilevered areas R43 X X R30 Batt Insul. + 2" SPRAY FOAM Room over garage FLOOR R43 X X R30 Batt Insul. + 2" SPRAY FOAM Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Ave. U-Factor (excludes skylights & one door) U: 0.30 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.32 R-value MECHANICAL SYSTEMS Make-up Air Select aType Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Electric Electric Passive Manufacturer LENNOX RHEEM LENNOX Powered EL296UH090 Interlocked with exhaust device. Model KV148C RHE- PR052-2 13ACX-026-230 Describe: l't'"t'° 87,000 Capacityin 50 Gal Output ill 3 TON Other, describe: Rating or Size 2 STAGE nruS: Gallons: Ton,: I teat 61,313 Heat Gain: 30,647 Location of duct or system: Structure's Calculated Loss: AFUE 96% SEER: 14.5 or liSPP°,', Calculated 30,647 Efficiency Cooling load: Cfin's round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech. code Select Type Passive X Heat Raver Ventilator. (IiRV) Capacity in cfins: Low: 90 High: 140 Other, describe: Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: N/A Location of fan(s), describe: Cfin's Capacity continuous ventilation rate in efins: " round duct OR FLEX Total ventilation (intermittent + continuous) rate in cfins: " metal duct Created by BAM version 052009 Job: Project Summary Date: Dec 20, 2012 Entire House By: °r E "'I ENERTECH , ; E'ER 0 7 Project Information For: Better Air, Bierlein Residence 4926 Jamie Rose Court, Eagan, MN Notes: Design Information Weather: Minneapolis-St Paul Intl Arp, MN, US Winter Design Conditions Summer Design Conditions Outside db -15 IF Outside db 88 IF Inside db 70 cF Inside db 72 cF Design TD 85 OF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 38 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 53603 Btuh Structure 22913 Btuh Ducts 0 Btuh Central vent (170 cfm) 7710 Btuh Central vent (180 cfm) 3054 Btuh Humidification 0 Btuh Blower 0 Btuh Piping Btuh Equipment load 61313 u Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 24123 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight 0 Structure 2024 Btuh Fireplaces Ducts 0 Btuh Heating Cooling Central vent (180 cfm) 4499 Btuh Area (ft2) 4245 4245 Equipment latent load 6524 Btuh Volume (ft3) 35121 35121 Air changes/hour 0.13 0.07 Equipment total load 30647 Btuh Equiv. AVF (cfm) 76 41 Req. total capacity at 0,70 SHR n Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade ELITE 90 Trade 13ACX SERIES Model EL296UH090XV48C Cond 13ACX-036-230-17 AHRI ref 4988513 Coil C33-43+EL296UH090XV48C'+TDR+TXV AHRI ref 5285676 Efficiency 96AFUE Efficiency 11.0 EER, 14.5 SEER Heating input 87000 MBtuh Sensible cooling 25060 Btuh Heating output 84000 Btuh Latent cooling 10740 Btuh Temperature rise 66 OF Total cooling 35800 Btuh Actual air flow 1193 cfm Actual air flow 1193 cfm Air flow factor 0.022 cfm/Btuh Air flow factor 0,052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 Boldlitalia values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-25 10:05:06 1 wrightsoftt Right surte® Universal 2012 12.0.13 RSU02669 Page 1 c:'.Users`, Jet l,,DocomentsM,igntsoff 1-IVAMSetier Air, Bierlein rup Calc = MJ8 Pont Door faces. Job: Load Short Form Date: Dec 20, 2012 Entire House By: R F C r: I V ENERTECH FEB d 7 M13 Project For: Better Air, Bierlein Residence 4926 Jamie Rose Court, Eagan, MN Design Information Htg Clg Infiltration Outside db (°F) -15 88 ✓ Method Simplified Inside db (°F) 70 72 Construction quality Tight Design TD (°F) 85 16 Fireplaces 0 Daily range M Inside humidity 40 50 Moisture difference (gr/lb) 43 38 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade ELITE 90 Trade 13ACX SERIES Model EL296UH090XV48C Cond 13ACX-036-230-17 AHRI ref 4986513 Coil C33-43+EL296UH090XV48C`+TDR+TXV AHRI ref 5285676 Efficiency 96 AFUE Efficiency 11.0 EER. 14.5 SEER Heating input 87000 MBtuh Sensible cooling 25060 Btuh Heating output 84000 Btuh Latent cooling 10740 Btuh Temperature rise 66 OF Total cooling 35800 Btuh Actual air flow 1193 cfm Actual air flow 1193 cfm Air flow factor 0.022 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Lower Level 1266 17617 5633 392 293 Entry Level 1199 14025 7669 312 399 Grt Room below rf 77 2181 1143 49 59 Upper Level 1189 10946 5413 244 282 Cant 24 1516 760 34 40 Upper ovr garage 490 7318 2295 163 120 Entire House 4245 53603 22913 1193 1193 Other equip loads 7710 3054 Equip. @ 0.93 RSM 24123 Latent cooling 6524 TOTALS 4245 61313 30647 1193 1193 Bold/ileHe values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jan-25 10:05:06 wrightSOft° Right-5wte® Universal 2012 12 0 13 RSU02669 Page 1 AM G:, Users'. Jeffrpocurnents W•rgntsoft HVACtiSetter Air, Bter,eTi rup Galc = MJ8 Front Door faces. Job: Budding Analysis Date: Dec 20, 2012 Entire House By: Er,!- I,,,- i ENERTECH Project Information For: Better Air, Bierlein Residence 4926 Jamie Rose Court, Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Paul Int'I Arp, MN, US Indoor temperature (°F) 70 72 Elevation: 837 It Design TD (°F 85 16 Latitude: 45 °N Relative humidity 40 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 43.1 37.9 Dry bulb VF) -15 88 Infiltration: Simplified Daily range (°F) - 18 ( M) Method Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 6.1 25422 41.5 Glazing 24.9 11034 18.0 Doors 40.8 1714 2.8 Ceilings 2.0 3512 5.7 Floors 2.8 5019 8.2 Infiltration 1.6 6902 11.3 w, Ducts 0 0 Piping 0 0 , Humidification 0 0 Ventilation 7710 12.6 Adjustments 61313 100.0 Total i Component- Btuh/ft2 Btuh % of load Walls 1.4 5649 21.8 w Glazing 25.9 11467 44.2 Doors 117 574 2.2 Ceilings 12 2146 8.3 Floors 0.0 31 0.1 „ Infiltration 0.2 695 2.7 Ducts 0 0 Ventilation 3054 11.8 Internal gains 2350 9.1. Blower 0 0 Adjustments 0 Total 25967 100.0 . Latent Cooling Load = 6524 Btuh Overall U-value = 0.066 Btuh/ft2- °F Data entries checked. Bold/Retie values have been manually a-ridden wri htsotft' 2013-Jan-25 10:05:06 R:gnl-Su?te® Unwersai 2012 12 0,13 RSUD2669 Page 1 C'. `,users ',Jeffrpocuments,Wegh{Soft HVACiBetter A!r, Bienem.rup Caic - MJ8 Front Door faces. Component Constructions DJob; ate; Dec 20, 2012 Entire House By: ENERTECH Q 17, r 1 1 V 17- 0 FEB a--7 2013 For. Better Air. Bierlein Residence 4926 Jamie Rose Court. Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Paul Int'I Arp, MN, US Indoor temperature (°F) 70 72 Elevation: 837 ft Design TD (°F) 85 16 Latitude: 45 ON Relative humidity 40 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 43.1 37.9 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 18 ( M) Method Simplified Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain it, swh,fl= IF m-'F.B1uh stuh,m atuh gtuhm' eluh Walls 12E-Osw: Frm wall, mtl ext, 112" wood shth, CIA av ins, 112" gypsum n 188 0.068 19.0 5.78 1084 1.32 247 board int fnsh, 2"x6" wood frm s 142 0.068 19.0 5.78 820 1.32 187 sw 1 0.068 19.0 5.78 9 1.32 2 w 171 0.068 19.0 5.78 991 1.32 226 all 502 0.068 19.0 5.78 2903 132 661 12E-Osw: Frm wall, vnl ext, 318" wood sht cri av ins, 112" gypsum n 99 0.068 19,0 5.78 572 1.32 130 ooard int fnsh. 2"x6" wood fm a 246 0.068 19.0 5.78 1424 1.32 324 all 345 0.068 19.0 5.78 1996 1.32 454 12E-Osw: Frm wall, vnl ext, 1!2" wood shth r-19 av ins, 1/2" gypsum n 517 0.068 19.0 5.78 2986 1.32 680 board int fnsh, 2"x6" wood firm ne 13 0.068 19.0 5.78 73 1.32 17 e 559 0.068 19.0 5.78 3232 1.32 736 se 13 0.068 19.0 5.78 73 1.32 17 s 520 0.068 19.0 5.78 3006 1.32 684 w 269 0.068 19.0 5.78 1556 1.32 354 all 1890 0,068 19-0 5.78 10927 1.32 2487 151311-8wc-4; 13 l heavy dry or light damp soil, 2"x4" wood int frm, n 234 0.043 19.0 4.34 1014 0.46 108 concrete wall r 10 ins, " thk, 1 i2" gypsum board int fnsh s 27 0.043 19.0 4.34 117 0.46 12 w 351 0.043 19.0 4.34 1522 0.46 162 all 612 0.043 19.0 4.34 2653 0.46 282 12A Frm wall, vnl ext, 112" wood shth, 112" gypsum board int a 351 0.106 6.0 9.01 3163 2.49 872 fnsh r-10 xt b d ins, 2"x4" wood frm ~fM v47$7+ s 306 0.106 6.0 9.01 2757 2.49 761 all 657 0.106 6.0 9.01 5920 2.49 1633 Partitions 12E-Osw. Frm wall. 318" wood srlth r 19 av ins, 518" gypsum board 177 0.068 19.0 5.78 1023 0,74 132 int fnsh. 2"x6" wood frm; Windows 2 glazing, clr low-e outr, argon gas. insulated vinyl frm mat, Or innr, n 8 D228 0 23.8 200 10.3 87 114" gap, 1/8" thk: 2 glazing, cir low-e outr, argon gas, insulated vinyl s 20 0 23.8 476 18.9 377 frm mat. Or innr, 114" gap, 1/8" thk; NFRC rated (SHGC=0.31) w 20 0 23.8 472 33.4 662 all 48 0 23.8 1148 233 1126 2013-Jan-25 10.05:06 .4, + wrightsoft' R;g1t-Sxle9 Un versal 2012 12.0.13 RSUD2669 Page 1 Zdk C.`UserskJelf\DxumentstWrightsoft HVAC%Better Air, Bierlem.rup Caic - MJ6 Front Door faces: 2 glazing, cir low-e outr, argon gas. insulated vinyl frm mat, cir innr. n 25 0280 0 23.8 595 10.7 267 114" gap, 1/8" thk: 2 glazing, cir low-e outr, argon gas, insulated vinyl a 29 0.280 0 23.8 690 352 1022 frm mat, cir innr, 114" gap, 1/8" 1hk: NFRC rated (SHG_ C=0.33) s 32 0.280 0 23.8 762 19.8 633 w 11 0280 0 218 250 352 370 all 97 0. 0 23.8 2297 23.8 2292 2 glazing.. clr low-e outr, argon gas. insulated vinyl frm mat, cir innr, n 87 0.300 0 25.5 2227 11.7 1026 1/4" gap, 1/8" thk: 2 glazing, cir low-e outr, argon gas, insulated vinyl ne 13 0.300 0 25.5 325 27.0 345 frm mat, Or innr, 114" gap, 118" thk: NFRC rated SHGC=0.37 a 55 0.300 0 25.5 1398 39.3 2154 se 13 0.300 0 25.5 325 35.0 447 w 25 0.300 0 25-5 646 39.3 995 all 193 0.300 0 25.5 4922 25.7 4967 2 glazing. cl, outr,. air gas, vni frm mat, cir innr. 14" gap, 1r4" thk 2 e 69 0 0 25.5 1750 34.6 2376 glazing, Or outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk, NFRC rated (SHGC=032) 2 glazing, cir low-e outr, argon gas, insulated vinyl frm mat, cir innr, s 36 0.300 0 25.5 918 19.6 707 1/4" gap, 1 8" thk: 2 glazing, cir low-e outr, argon gas, insulated vinyl firm mat, cir innr. 1/4" gap, 1/8" thk: NFRC rated (SHGC=0.32) Doors Door, mtl fbrgi type, mtl strm: Door, mtl fbrgl type, mil strm s 21 0.360 24.0 30.6 643 10.2 215 11JO: Door, mtl fbrgi type n 21 0.600 6.3 51.0 1071 171 358 Ceilings 16B-44ad: Attic ceiling, asphalt shingles roof mat, r 44 eil ins, 5/8" 1703 0.022 44.0 1.87 3185 1.14 1946 gypsum board int fnsh 16B-44ad: Attic ceiling, asphalt shingles roof mat, 4 ell ins 77 0.022 44.0 1.87 144 1.14 88 C part ceiling,: C part ceiling, carpet fir fnsh, frm fir, 12" thkns, 5%8" 10 0.216 1.0 18.3 183 11.2 112 gypsum board int fnsh Floors 19A-Obswp: Part floor. hrd wd fir Irish, frm fir, 12" thkns, 5/8" gypsum 2 10 0.295 O 9.42 94 1.76 18 board int fnsh A 21A-20c: Bg floor, heavy dry or light damp soil, 2' depth, carpet fir fnsh 1266 0.027 2.30 2905 0 0 Fir floor, Irm fir, 12" thkns, carpet fir fnsh 43 av ins, tight crwl ovr, 488 0.047 43.0 3.99 1950 0 0 r-11 wall insul Fir floor, frm fir, 12" thkns. r•pet fir fnsh, r-43 cav ins, tight crwi ovr, r-11 wall insui Part floor. carpet fir fnsh, frm fir, 12" thkrlS, 5/8" gypsum board int fnsh: 2 0.295 43.0 9.42 19 1.76 4 Part floor, carpet fir Irish, frm fir, 12" thins, 5/8" gypsum board int Irish Part floor, carpet fir fnsh, r-43 ins r. 12" thkns, 5/8" gypsum board 24 0.029 43.0 2.12 51 0.40 10 int fnsh: Part floor, carpet fir fns , r 43 i s, frm fir, 12" thkns, 518" gypsum board int fnsh 2013-Jan-25 10:05:06 Wrightsoft" Right-SxteO Universal 2012 12 0,13 RSU02669 Page 2 0 . Users\Jeff,,DocuTrents',Wr,ghtsoft HVACiBetter A,c Bier3en.rup Calc = MJB Font Door faces: Ri ht-JO Worksheet Job: g Date: Doc zo, 202 Entire House By: ENERTECH Erg ire House Lower Level 1 Room name ~ 8 It 152.0 It 2 Exposed wall 8.6 If 9.0 It heat/cool 3 Room height 1.0 x 1266.0 It 4 Room dimensions 5 Room area 4245 0 112 1266,0 112 Ty Construction U value Or HTM Area (l Load Area (ftq Load number 91uh11t2-°F) (Btutuft2) or perimeter (ft) (Btuh) or perimeter (ft) (Stun) Heat Cool Gross N/P!S Heat Cool Gross NrP,S Heat cool 6 12E-0sw 0.068 n 5.78 1-32 196 188 1084 247 0 0 0 0 1--G 2 glazing, Or low,e 0 280 n 23.80 10.30 8 0 200 87 0 0 0 0 W 12E-Dsw 0.068 n 5.78 1 32 99 99 572 130 99 99 572 130 Vy 12E-Osw 0068 n 5.78 1.32 629 517 2986 680 0 0 0 0 11 {-C 2 glazing. cir low-e 0.280 n 23.80 10.68 25 0 595 267 0 0 0 0 E-(' ' 2 glazing, cir low-e 0.300 n 25.50 11.75 87 0 2227 1026 0 0 0 0 W 151311 8wc 4 0.055 n 4.34 0.46 234 234 1014 108 234 234 1014 108 1y 12E-Osw 0.068 ne 5.78 1.32 25 13 73 17 0 0 0 0 t--43 3 2 glazing, clr low-e 0 3D0 ne 25.50 27.04 13 0 325 345 0 0 0 0 W 12A 6sw 0 106 a 9.01 2.49 351 351 3163 872 351 351 3163 872 12E-0sw 0.068 a 5.78 112 315 246 1424 324 315 246 1424 324 t --G 2 glazng, cir outr, 0 300 a 25.50 34.62 69 0 1750 2376 69 0 1750 2376 12E-Osw 0.068 a 518 1 32 643 559 3232 736 0 0 D 0 VLt 2 glazing, cir low-e 0.280 a 2180 35.23 29 0 690 1022 0 0 0 0 2 glazing, cir low-e 0.300 a 25.50 39.28 55 0 1398 2154 0 0 0 0 Vy 12E-Osw 0-068 se 5,78 1.32 25 13 73 17 0 0 0 0 i---C 2 glazing, cir tow-e 0.300 se 25:50 35.03 13 0 325 447 0 0 0 W 12A 6sw 0.106 s 9,01 2.49 306 306 2757 761 306 3D6 2757 761 W 12E-0sw 0.068 s 5.78 1.32 142 142 820 187 0 0 0 0 12E Osw 0.068 s 5.78 1.32 629 520 3006 684 0 0 0 0 19 2 glazing, cir low -e 0.280 s 23.80 18.86 20 0 476 377 O 0 0 0 2 glazing, cir law -e 0280 s 23.80 19.79 32 0 762 633 2 gazing, cir low -e 0,300 s 25.50 19.65 36 0 918 707 0 0 0 0 Door. mti fbrgi IvDe 0.360 s 30.60 10.24 21 21 643 215 0 0 0 0 W 15B11.8wc-4 0.055 s 4.34 0.46 27 27 117 12 27 27 117 12 W 12E Osw 0.068 sw 5.78 1.32 1 1 9 2 0 0 0 0 12E-0sw 0.068 w 5.78 132 191 171 991 226 0 0 0 0 2 glazing. Gr low-e 0.280 w 23:8D 33.37 20 0 472 662 0 0: 0 0 t-0 Val 12E-Dsw 0.068 w 5.78 1.32 30.5 269 1556 354 0 0 D 0 F- 2 grazing: Cif low a 0280 w 23.80 35.23 11 0 250 370 0 0 O 0 ::2 2 gluing cir low-e 0.300 w 25.50 39.28 25 0 646 9% W 15611.8we 4 0.055 w 4.34 0.46 351 351 1522 162 351 351 1522 162 Pt _ 12E -Osw D 068 - 5.78 0 74 198 177 1023 132 0 0 0 0 L---J 11J0 0 600 n 51 00 17 07 21 21 1071 358 0 0 0 0 G 16B-44ad 0.022 1.87 1.14 1703 1703 3185 1946 0 0 0 0 C 16B-44ad 0 022 1.87 1.14 77 77 144 88 0 0 0 0 C C pars ceiling. 0.216 18.33 11.20 10 10 183 112 0 0 0 0 F 19A Obswp 0.295 9.42 1 76 10 10 94 18 0 0 0 0 F 21A-20c 0.027 2.30 O.DD 1286 1266 2905 0 1266 1266 2905 0 F Fir Boor, frm fir, 0047 3.99 0.00 488 488 1950 D 0 0 0 0 F Part floor, carpet t 0.295 9.42 1.76 2 2 19 4 0 0 0 0 F Part floor, carnet t 0.029 2.12 0.40 24 24 51 10 0 0 0 0 6 c) AED excursion 0 187 Envelope loss/gain 46700 19W 15224 4932 12 a) Infiltration 6902 695 2393 241 b) Room ventuahon D 0 0 0 13 lnlernaigains: Occupants @ 230 5 1150 2 460 App!+.ancesrother 1204 0 Subtotal pines 6 to 13) 53603 22913 17617 5633 Less extemai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 17610 0 14 Subtotal 53603 22913 15 Duct loads 0°t 0% 0 0 -O% 0°l0 0 0 53603 22913 17617 5633 Total oo? 'sad 1193 1193 392 293 Air •eyu;,e ',cim) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AG~. WrightsofI 2013-Jan-2510:05:IX9 Right-Su te®Umversa! 2012 12.0.13 RSU02669 Page 1 G': UserstJeff'Documents\Wnghtsoft HVACiSetter Air, Bierem.rup Caic - MJ8 Front Door faces: Ri ht-JO Worksheet Job' 9 Date: Dec 20, 2012 Entire House By: ENERTECH 1 Room name Entry Level Grt Room below rt 2 Exposed wall 113.6 it 18.0 ft 3 Room height 9.0 it heat/cool 9.0 it heat/cool 1.0 x 1199.0 It 11.0 x 7.0 it 4 Room dimensions 5 Room area 1199.0 ft2 77.0 ftz Ty Construction U-vaiue Or HTM Area (ft') Load Area (ftq Load number (Btuh:fl%- F) (Btut Itt') or perimeter (it) (BI h) or perimeter (it) (Btuh) Heat Coal Gross WPIS Heat Cod Grams li Heat cool 6 Y►i 12E-Osw 0.068 n 5.78 1,32 0 D 0 0 0 0 0 0 L_.t 2 glazing, cir lbw-e 0.280 n 23.80 10:30 0 0 0 0 0 0 0 0 W 12E-Osw 0.058 n 5.78 1.32 0 0 0 0 0 0 0 0 12E Osw 0.068 n 5.78 1.32 234 174 1OD7 229 98 72 413 94 ,Lt 2 glazing, cir iow-e 0.280 n 23.80 I D.68 0 0 0 0 0 0 0 0 11 2 glazing, Gr low-e 0.300 n 25.50 11.75 60 0 1526 703 28 0 701 323 W 153 11.8wc-4 0.055 n 434 0.46 0 0 0 0 0 0 0 0 Vy 12E-Osw 0.068 ne 5 78 1.32 25 13 73 17 0 0 0 0 r G 2 glazing, clr low-e 0.300 ne 25.50 27.04 13 0 325 345 0 0 0 0 W 12A-5sw 0106 a 9.01 2.49 0 0 0 0 0 0 0 0 12E -Osw 0.068 a 5:78 1.32 0 0 0 0 0 0 0 0 t --G 2 glazing, clr out,. 0.300 a 25.50 34.62 0 0 0 0 0 0 0 0 63 12E-Osw 0.068 a 5.78 1.32 252 212 1226 279 63 D O 270 0 2 glazing, cir low-e 0.280 a 23.80 35-23 0 0 0 O 2 glazing, clr low a 0.300 a 25.50 39.28 40 0 1016 1565 15 0 383 589 Vy 12E-0sw 0.068 se 5,78 1.32 25 13 73 17 0 0 0 0 ~G 2 glazing, Or iow-e 0.300 se 2550 35.03 13 D 325 447 0 0 0 0 W 12A-6sw 01106 s 9.01 2.49 0 0 0 0 0 0 0 0 W 12E-Dsw 0.068 s 5.78 1.32 0 0 0 0 0 0 0 0 12E-Osw D.D68 s 5.78 1.32 333 280 1618 368 0 0 0 0 14 2 glazing, cr low -e 0.280 s 23-80 18.86 20 0 476 377 0 0 0 0 2 giazing, cir low -e 0.280 s 23.80 19.79 0 0 0 0 0 0 0 0 2 glazing, Or low a 0.300 s 25.50 19.65 12 0 306 236 0 0 0 0 Door, mill fbrgI tvpe 0360 s 30.60 10.24 21 21 643 215 0 0 0 D W 15B11-8wc-4 0055 s 4.34 0.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 5.78 1.32 0 0 0 0 0 0 0 0 12E-Osw 0,068 w 5.78 1.32 0 0 0 0 0 0 0 0 t -G 2 glazing, cir taw-e 0.280 w 23:80 33.37 0 0 0 0 0 0 D 0 12E Osw 0-068 w 5.78 1.32 153 128 738 168 p D 0 0 2 glazing, cir low-e 0 280 w 23,80 35.23 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0 300 w 25.50 39.28 25 0 646 995 0 0 0 0 W 15B11-8wc-4 0055 w 4.34 046 0 0 0 0 R. 12E Osw 0 068 - 5.78 0.74 198 177 1023 132 0 0 0 0 L-D 11JO 0.600 n 51.00 17.07 21 21 1071 358 0 0 0 0 1.87 1,14 0 0 0_ 0 0 0 0 0 C 168-44ad 0022 C t fib-44ad 0.022 - 1.87 1.14 0 0 0 0 77 77 t 44 88 C C part ceiling, 0,216 18.33 11-20 10 10 183 112 0 0 0 0 F 19A-Obswp 0.295 9.42 1.76 10 10 94 18 0 0 0 0 F 21A-20c 0.027 2.30 0.00 0 0 0 0 0 0 0 0 F Fir floor, frm f1r, 00,047 3.99 000 0 D 0 0 0 0 0 0 F Part floor, carpet f 0 295 9.42 1.76 0 0 0 0 0 0 0 0 F Part floor. carpet t 0 029 2.12 0 40 0 0 0 0 0 0 0 0 6 c1 AED excursion -278 41 Envelopeloss,'gain 12370 6302 1918 1116 12 a) sntdtration 1655 167 262 26 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances!other 12W 0 Subtotal (lines 6 to 13) 14025 7669 2181 1143 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14025 7669 2181 1143 15 Duct lards -0-/0 0°io 0 0 IN. M 0 0 Tata room oad 14025 7669 2181 1143 Air required (cfm) 312 399 49 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'Ill wr'ightsia t, 2013 Jan-25 10:05:06 Riga: SUteN Un ve*sai 2012 12-0.13 RSU02669 Page 2 ~A C Users-.Jeti'Doc~merts Wrgntso!t HVAC`,Betiel A Beene n rip Ca-c = MJB Front Door faces: Right-JO Worksheet Date: Job: Doc 20, 2012 Entire House By: ENERTECH t Room name Upper Level Cart 2 Exposed wall 118,0 If 16.0 It 3 Room height 80 it heat/cod 8.0 If heat!cool 4 Room dimensions 1 0 x 1189.0 It 12.0 x 2.0 It 5 Room area 1189.0 It, 24,0 ft` Ty Construction U vats Or HTM Area (ttz) Load Area (ftz) Load number (Btutvft'-'F) (Btu It') or perimeter (ft) (Bt h) or perimeter (ft) (Btuh) Heat Cool Gross N'P'S Heat Cod Gross N!P/S rro Cod 6 W 12E-Osw 0.068 n 5.78 1.32 0 0 0 0 0 0 0 t--1 2 glazing, Or low-e 0.280 n 23.80 10.30 0 0 0 0 0 t? 0 W 12E-OSw 0.066 n 5.78 1.32 0 0 0 0 0 0 0 V~ 12E-Osw 0.086 n 5.78 1:32 296 271 1568 357 0 0 0 0 11 )-G 2 glazing, Or low -e 0.280 n 23.80 10.68 25 0 ` 7 0 p 0 l.-C 2 glazing, clr low-e 0300 n 2550 11.75 0 O 0 0 p 0 0 0 W 15Bit 8wc-4 0055 n 434 0.46 0 0 0 0 12E-Osw 0,068 ne 5.78 1.32 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0,300 ne 25,50 27.04 0 0 0 0 W 12A-6sw 0.106 a 9.01 2.49 0 0 0 0 0 0 0 0 12E-Osw 0.068 a 5.78 1:32 0 0 0 0 0" 0 0 0 2 glazing, clr outs, 0.300 a 25,50 34.62 0 0 0 0 16 6 16 92 20 12E-Osw 0 068 a 518 1.32 312 283 1636 372 O 2 glazing, clr low-e 0-280 a 23.80 35.23 29 0 690 1022 0 0 0 0 1 :2 2 glazing, clr low-e 0.300 a 25.50 39.28 0 0 0 0 0 0 0 12E-Osw 0-068 se 5.78 1.32 0 0 0 0 0 0 0 0 2 glazing. clr low-e 0.300 se 25.50 35.03 0 0 0 0 0 0 0 0 W 12A 6sw 0 106 s 9.01 2.49 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 5.78 1.32 0 0 0 0 0 0 - 0 0 1260sw 0 068 s 5 78 1 32 200 168 971 221 96 72 416 95 2 glazing, cir low-e 0280 s 23.80 18.86 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.280 s 23.80 19.79 32 0 762 633 0 0 0 0 2 glazing, clr low ,e 0.300 s 2550 19.65 0 0 0 0 24 0 6120 472 Door, mtl tbrgl type 0.360 s 30.60 10.24 0 0 0 0 0 0 p 0 W 15B 11-8wc-4 0.055 s 4.34 0.46 0 0 0 0 W 12E-0sw 0.068 sw 5.78 1-32 0 0 0 0 0 0 0 0 4~ 12E-Osw OMB w 5.78 1.32 0 0 0 0 0 t7 0 0 t-- G G 2 glazing, clr tow -e 0:280 w 23.80 33.37 0 0 0 0 0 0 0 0 W 12E Osw 0.068 w 5.78 t 32 136 126 725 165 16 16 92 21 ~--CC 2 glazing, cir low -e 0.280 w 23.80 35.23 11 0 250 370 0 0 0 6 L G 2 glazing, cr !ow e 0.300 w 25 50 39.28 0 0 0 0 0 0 0 W 15811.8wc 4 0.055 w 4.34 046 0 0 0 0 0 0 0 0 P. 12E-Osw 0 068 5.78 0 74 0 0 0 0 0 0 0 0 L_-D 1150 0.600 n 51.00 17.07 0 0 0 0 0 0 0 0 C 16B-44ad 0.072 1.87 1.14 1189 1189 2223 1359 24 24 45 27 C 168-44ad 0 022 1.87 1,14 0 0 0 0 0 0 0 0 C C part ceiling. 0.216 18.33 11.20 0 0 0 0 0 0 0 0 F 19A-Obswp 0 295 9.42 1 76 0 0 0 0 F 21A-20c 0.027 2.30 0.00 0 0 0 0 0 0 0 0 F Fir floor trm Mr. 0 047 399 0-00 0 0 0 0 0 F Part floor, carpet t 0.295 9.42 116 0 0 0 0 0 0 0 0 F Part !loor carpet 1 0 029 2.12 040 0 0 0 0 24 24 51 10 6 cj AED excursion 196 93 Enveiooe iDsS!gain 9419 4570 1309 739 12 a) =nh1tratia1 1527 154 2070 21 b) Room ventilation 0 0 13 internal gains: Occupants @ 230 3 690 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 10946 5413 1516 760 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistributiorn 0 0 0 0 14 Subtotal 10946 5413 1516 760 15 Duct 'oads 0% 0% 0 D 0°i 0% 0 0 10946 5413 1516 760 Total room load 244 282 34 40 Air required (cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsotTt- 2013-Jan-25 10.05.06 Right-Su-tog Urlwwsai 2012 12 0 13 RSU02669 Page 3 Ar- C ' Jse,s`,Jeff Jr,)cj,*reatsWcyntsoft HVAC,,Be.te- Air 3~e,'e;n rup Ca.c = MJ8 -,on, Door !aces. Right-JO Worksheet Job: Date: Dec 20, 2012 Entire House By: ENERTECH 1 Room name Upper ovr garage 2 Exposed wai! 66.3 It 3 Room iegnt 8,0 ft heat/Cool 4 Room dr_merlsions 1'0 x 490.0 it 490.0 its 5 Roam area 7y Construction U-value Or HTM Area (99 Load Area Load number (Btuhlitz-'F) (Btu tutY I tq or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat cool yl 12E-Osw 0.068 n 5.78 1.32 1965 186 1084 47 61--+C 2 glazing. cir low-e 0.280 n 23.81 10.30 8 D ~ O 32 0 w 12E Osw 0.068 n 5.76 1.32 0 VL:t 12E.Osw 0 068 n 5.75 1.32 0 0 0 0 11 2 glaz+ng, clr low -e 0.280 n 2180 10.68 0 0 0 0 2 glazing, cir low-e 0,300 n 25.50 11.75 0 0 0 0 W 1513 11.8wc-4 0.055 n 4.34 0.46 0 0 Yy 12E-Osw 0,066 ne 5.78 1.32 0 0 0 0 0 t.--G 2 glazing, clr ow-e 0,300 ne 25.50 27.04 0 0 w 12A-6sw 0.106 a 9.01 249 0 0 0 0 Vy 12E-Osw 0.068 a 5:78 1.32 0 0 0 0 t--{, 2 glazing, cir outr, 0-300 a 25.50 34.62 0 0 0 1 12E-Osw 0-068 a 5.78 1.32 0 0 0 0 G 2 glazing. clr low-e 0.280 a 23.80 35-23 0 0 0 ttt---_(GG' 2 glazing. cir low-e 0,300 a 25.50 39.28 0 0 0 0 Vy 12E-Osw 0 066 se 5.78 1 32 0 0 0 t--G 2 glazing.. cir tow-e 0 300 se 25,50 35.03 0 0 0 0 w 12A 6sw 0 106 s 9.01 2.49 0 0 0 0 w 12E-Osw 0 058 s 5.78 1.32 142 142 820 187 12E-0sw 0,068 s 5.78 1,32 0 0 0 0 2 glazing, cir low a 0280 s 23.80 18,86 0 0 0 0 2 glazing, cir low-e 0.280 s 23,130 19.79 0 0 0 2 glazing, cir low-e OMD s 25,50 19,65 0 0 0 0 Door, mtl fbrgl type 0.360 s 30.60 1024 0 0 0 0 w 15811-8wc-4 0.055 s 414 0.46 0 0 0 0 w 12E -Osw 0.068 sw 5.78 1,32 1 1 9 2 w 12E-Osw 0"068 w 5.78 1,32 191 171 991 226 t --G 2 glazing, cir low-e 0280 w 23.80 3337 20 0 472 662 Vj1 12E Osw 0066 w 5 78 1 32 0 0 0 0 ►-Ca 2 glazing. cir low-e 0,280 w 23,80 35.23 0 0 0 0 2 2 glazing. cir low "e 0.300 w 25.50 39.28 0 0 0 0 w 15811-8wc-4 0.055 w 4.34 0.46 0 0 P 12E-Osw 0.068 - 5.78 0.74 0 0 0 0 11J0 0,600 n 51.00 17,07 0 0 0 0 C 16B-44ad 0.022 1.87 1.14 490 490 916 560 C 1613-44ad 0.022 1,87 114 0 0 0 0 C C part ceiling. 0.216 18.33 11.20 0 0 0 0 F 19A-Obswp 0 295 9 42 1 76 0 0 0 0 F 21A-20c 0 027 2,30 0.00 0 0 0 0 F Fr f oo" trm 1 0 047 3.99 0 00 488 488 1950 0 F Pan floor carpet t 0295 942 136 2 2 19 4 F Part floor, caroet t 0.029 2 12 040 0 0 0 0 6 c) AED excursion 236 Envelope loss gain 6460 2209 12 a) inltiration 858 86 b) Room ventilation 0 0 13 Internal gains. Occupants @ 230 0 0 Appliances/other 0 Subtotal dines 6 to 13) 7318 2295 Less external?oad 0 0 Less transler 0 0 Redrst,bution 0 0 14 Subtotal 7318 2295 15 Duct loads 01/6 0 0 Total room load 7318 2295 Air required (ctm) 163 120 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- W rightscPft, 2013-Jan-25 10.05.06 ~ H,git-Su,len U-,versa 2012 12 0 13 RSU02669 Page 4 ,;..Jse,s.Jetf'Docoments vvr,gntsott HVAC',.Better Air Bterteri.sup Calc = MJ8 Front Door faces: 'ventilation, Makeup and Combustion Air Calculations Instructions and Example These irss and blank submittal tams are available at Ste Building Safety wabsite and at the Building Safety 01111xr. The oomplated form mum be submitted at the time of application of s mechanical permit for new construction. Ad(Wonal fmm may be downloaded and Printed at www Awbo . epar"mtsft11AVcod4mgmm. SIW&ddnmw Mute complew Section A Ventilation Quanft peterrwrie Wer Y by uskV Table N1104.2 or Edon 11-1) t heal or untunistted) ' we Total requ lmd ve ors 1e- Number of bedmoms Undi sous ventilation Directions • Determine the total and continuous ventilation rate by either using Table N2 104.2 orequation 11-1. Insert the square footage, total required vent alim and continuous ventilation in the Mechanical Submittal farm. The table and equation are below. Table N1104.2 Total and Continuous Verb Ram in c1m Number of Sedmoms .1 2 3 4 5 6 Conditioned spy Total Totall Total Total Total! Total (in sq. ft.) continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90145 105/53 120/60 135168 1501.2000 70140 85!43 100160 115/58 130/65 145173 2001-2500 80140 95/48 110155 125/63 140170 155178 2501-3000 90/45 106153 120/60 135/68 150/75 186183 3001-3500 100160 115158 130/65 145173 160180 176/88 3501-4000 110166 125 *3 140/70 155178 170185 185/93 4001-4600 120160 136/68 150175 183 180190 195/98 4 - 130165 145/73 160180 175/88 190195 2061103 5001-5500 140110 155/78 170/85 18:5193 200/100 2'151108 5501-6400 150175 1661;83 180I9t) 1958 2101105 225/113 Equation 114 (0.02 x square feet of conditioned space) + (15 x (number of bedrooms + 1)) _ Total ventilation tote (cam) Example. (0.02 x 3000) +(15 x (3 + 1)J = Total ventilation rate = 120 cfm Total ventilation - The mechanical ventilation system shall provide sufficient oulloor air to equal the total ventilation rate average, for each ones-hour perms according the above table or equation. For hest recovery ventilators (I RV) and en- ergy recovery ventilators (ERV) ttae average hourly ventilation opacity must be determined in consideration of any reduc- ton of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 60 percent of the total ventilation rate, but not titan 40 gb stall be proves ad, on a continuous rate average for each one-hour period. The portion of the mechanical ventilation system Intended to be continuous may have automate cycling controls proving the average flew rate for each hour is met. verd4n •comb air INSTRUCnONS.doc Page 1 of 6 Directions,- In order to datermins the makeup air for ventlaWn, Table 501. must be films out (see below). For most new installations, column A will be appropriate, however, If kitchen hoods exceed 00 cfrtm, ahnosphencally vented appli- ances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is nega- tive, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening, Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section Gt. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUA LAITY FOR EXHAUST EQUIPMENT IN DWELLINGS AIt9itional mak air will be re for cxxnbustion appliances, see KA1R method for rifts One or multiple power One or multiple fan- Cine attnos lly Multiple atmosphed- vent or direct vent assisted appliances )vent gas or oil appil- tally vented gas or oil appliances or no cotn- and power vent or ante or one solid W appliances or solid bustion appliances direct vent appliances appliance fuel appliances Cann D Column A Column B column C 1 a) pressure faux 0.15 0.09 0.06 0.03 drat b) conditioned floor area (so (kid txi- 3ggg y in unfinished basements) sti at d House infiltration (Cft): 459 2. Exhaust Capacity a) continuous exhaust-only vertu. -44 tion system (cfm); (rte applicable to balanced ventilation systems such as b) clothes dryer (dm) 135 135 135 135 c) of largest exhaust rating (crm), (not applicable if recirculating sys- tem or if powered makeup air is electrically interlocked and mate to 2SO x . ? = ;?OG exhaust d) W°r6 of next largest exhaust rat- ing (cfm); . 90 A 100 (not applicable if recirculating syg_ tern or if powered makeup arr is NA '~O electrically interlocked and matted to exhaust Total Exhaust Capacity (cfm), 2a + 2b +2c + 2d 3. Makeup Au' Quantity (edm) a) total exhaust capacity (from a" above) 443, b) estimated rte infiltration (from above 458 63(4 Makeup Air Quantity (cfm); (if value is negative, no makeup air is needed 4. For makeup Air Qpenatg Sixkr, Not required, negative refer to Table 501 A.2 number A. Use this column if there are other than fan-assisted or atmospherical vented gas or oil appliance or if there are no combustion appilaric- es. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venter system. (Appliances other than atmospherically vented appliances may also be included.) C. Use this column if there Is one atmosphe rically vented (off than fan-assisted) gas or oil appliance per venting system or one solid fuel ap- pliance. D. Use this column if there are multiple atmospherically vertu gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Page 3 of 6 Ventilation, Makeup and Combustion Air Calculations - Please sit at time of application of a mechenical permit for new oonstauctiot. f 611*006 f • f - WA-C Contive1or oSft-ftn A Ventilation Quantity Potetttdme quantity by uWV Table N1104.2 or Equation 11-1) Square feet ( itioned area including t c Basement -finished at unfinished) Total required ventilation Number of bedrooms 5- Corftwous ventilation Section S Vent la#lon Method Choose either or Selamced, HRV 0* 9 ftoovery Ventilator) or ERV (Energy Exfmt* oay 'Recovery Ventilates c(m of tit In low rust not vowd cow Cw&K otm fan raft cfm tinums ventilation rati more than 100%. notaxosed I Low cirri: cdm. _ ors fan rating G 61M (capacity must contirurtat ventilation more areas 100% Bon ~ Ventil on Fan Schedule t)esc ' ' n Lo on Continuous Total Ventk tion won D contmis and cor" of the c onfi or SeCtIon Make-up air for ventilation Passive (determined from talc utatio'~s Table 601 A.1) Powered (determined from calculations from able 501.4.1) Interlaited with exhaust device (determined Qn- calcsMon from T $01 A.1) x r L.ocalttctrt of duet or $ystarri ven on make-up, air Determired from M" -W air qW" table cfmt Stm and type (round, rectangular. flexor` Sectim F Make-up air for combustion Not mired per meraretn code (No atmospheric or power vented appliances) ~ Ny'g Passive (see IFG Appendix E, Worksheet E-1) Size and type Other, describe; Notes, InsVuctions and example forms are available at the Building Safety website and at the Building Safety office. This Em- must be submitted at the time of application of a mechanical permit for new consiructism. Additional forms may be doamiooded and Printed at: http,:14v s~w.elfaribault mn.us/depa"ntslbuddingeode~m. City of Eapp Address: 4926 Jamie Rose Ct Zip: 55122 Permit #: 108956 The following items were / were not completed at the Final Inspection on: g/ -5l/ 3 Final grade - 6" from siding v Permanent steps — Garage Permanent steps — Main Entry Permanent Driveway v' Permanent Gas Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn vv Trail / Curb Damage Porch Lower Level Finish Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: G:\Building Inspections\FORMS\Checklists