Loading...
1449 Steeplechase Lane i 001gU J ( .00 Use BLUE or BLACK Ink p, I For Office Use I too 1 1 of ~i f ajan Permit city 1 I P " ermit Fee: 3830 Pilot Knob Road 7J~ Eagan MN 55122 Date Received: `3 Phone: (651) 675-5675 ) I I Fax: (651) 675-5694 1 Staff: frl I `________________J 2013 RESIDENTIAL BUILDING PERMIT APPLICATION Site Address: 14401 SrI~~P~f~e~tks~ LAJIL -Unit Name: _ TO Lt. NLO IA 9-0-Co l Jt.. Phone: 691 - 3 is S' O %a0 ~ Resident/ Owner Address / City / Zip: `I 0 $1rf pt.+-K C44 As 1= L V J9 0 1SA ".J 10 14414 S3riA Z Applicant is: Owner k Contractor L -S Lyz, 4 Type of Work Description of work: NEW S~ p /G+✓►'/~L 3• Vw+ J t rowAJ410A)e S tA1le. JSIT Multi-Family Building: (Yes _ / No ) Company: TO LA_ te 120THfl&S , ;AA- Contact: T0PJ Jh►W50 J Contractor Address: l ` qo Sr4PL tm*49F, (AWK city: Il..4%*A#J State: MA) Zip: SVol4 Phone: (OSl.31sa'01o*1 (OM) 40-3'87 1810 1 ` CAIN License SC_q S 3 tP1o Lead Certificate r J / A" If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) ,N -,.J P.k 51 A X-JfIt d 'T WoJ iM Drw K_ - tR *+r! tJ^ r. mpl A COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? _Yes X No If yes, date and address of master plan: Licensed Plumber: SPx1.%Jy ~~..1~I~ ~IwJb Phone: 74\0. 6,474c".3 Mechanical Contractor: RAy PI. WF-Lrf.,4 Ndhc. Phone: to, Z - SIT- (0$%01 Sewer & Water Contractor: pSNt EX~+4~i4riO.~ Phone: for)- 160 - 13 S S NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application fora permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. x Too N IEwi to-i x Applicant's Printed Name Page 1 of 3 DO NOT WRITE BELOW THIS LINE jQ SUB TYPES Foundation _ Fireplace _ Porch (3-Season) _ Storm Damage Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family) Multi Deck Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi) 01 of _ Plex _ Lower Level _ Pool _ Miscellaneous _ Accessory Building WORK TYPES New _ Interior Improvement _ Siding _ Demolish Building* Addition _ Move Building Reroof _ Demolish Interior Alteration Fire Repair Windows _ Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation Occupancy MCES System Plan Review Code Edition SAC Units 1 (25%_ 100% Zoning City Water Census Code Stories Booster Pump # of Units Square Feet 4 o3) PRV # of Buildings Length Fire Sprinklers Type of Construction V Width R QUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) _ Final / No C.O. Required Foundation e HVAC _ Gas Service Test Gas Line Air Test Drain Tile Other: Roof: -Ice & Water -Final Pool: -Footings Air/Gas Tests Final Framing Siding: -Stucco Lath Stone Lat -Brick Fireplace: -Rough In Air Test -Final Windows Insulation Retaining Wall:' all Footings Backfill Final Sheathing Radon Control Sheetrock Erosion Control Reviewed By: , Building Inspector RESIDENTIAL FEES Base Fee N j !p / Surcharge /17 ~ l~ Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Copies y~ TOTAL / f 7 9 L t~ 2,0 s age 2 of 3 Date: 3/22/2013 Revision Date: 3/22/2013 New Construction Site Information La4n e Address 1: Project Steeplechase of Eagan Address 2: Medina plan Lot: #57 Block: City: Eagan County: Subdivision: Application Information Business Name: Ray N. Welter Heating MN Contractor License Contact Person: Joe Office Ph: 612-825-6867 Fax: Cell Ph: Address 1: 4637 Chicago Ave. So. City: Minneapols State: MN. Zip Code: 55407 House Details Square Feet: 3434 sq. ft. Avg. Ceiling Ht: 10 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 150 cfm. Minimum Continuous Ventilation :45cfm. Continuous Ventilation Provided: Exhaust: 45 cfm Intermittent ventilation satisfied by OTHER exhuast appliance. i Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 60,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 400 Make-Up Air No Make-Up Air Required by Code Combustion Air Minimum Combustion Air Requirements Met. 7/7/ n Applicant Name (print): ~f~7t Signature/Date: Code Official (print): Signature/Dat © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 cc 3 ® M ® -1 rt PAD V °e fA \ h ro R y o0 - -T „r m o , o , L O O ` W ID rt rt bi a:) La G 3 co f ♦ l®I c ti► • CL _o ` N 1 69 40 z m $ a ~ as ~ n ~ ~ a A Wm ~ ~ 11 PV6 - - - - - 6 N r Load Short Form Job: Toll 3 Plex Wrlg~"1'I~SO~#e Date: Jul 19, , 201 2010 Medina B ~ - v: Ray N Welter Heating Co Lx~ J / - 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: owwv.welterheating.corn Project -information For: Design Information Htg Clg Infiltration Outside db (°F) -15 88 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 85 13 Fireplaces 3 (Average) Daily range - M Inside humidity 30 50 Moisture difference (gr/lb) 32 28 HEATING EQUIPMENT COOLING EQUIPMENT Make Trane Make Trane Trade Trane Trade XB 13 Model TUC1B060A9361A* Cond 4TTB3018A1 GAMA ID 164847 Coil 4TXFH018AS3+*DY060R9V3 ARI ref no. 1052010 Efficiency 92.1 AFUE Efficiency 11.2 EER, 13.3 SEER Heating input 60000 Btuh Sensible cooling 12320 Btuh Heating output 56000 Btuh Latent cooling 5280 Btuh Temperature rise 89 °F Total cooling 17600 Btuh Actual air flow 587 cfm Actual air flow 587 cfm Air flow factor 0.013 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O A Space thermostat Load sensible heat ratio 0.91 ROOM NAME Area Htg load Clg load HtgAVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Medina LH 1605 22209 9280 298 412 Medina Basement 1605 21472 3931 288 175 Medina 3210 43681 13211 587 587 Other equip loads 0 0 Equip. @ 0.93 RSM 12260 Latent cooling 1288 TOTALS 3210 43681 13548 587 587 Printout certified byACCA to meet all requirements of Manual J 8th Ed. -A- wrightsc ftw Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:4550 . W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 2 Job: Tol3 Plex fightso `Buildin Analysis Date: Jul 19, 2010 Medina By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: wvwvwelterheating.com P • - Information For: Design Conditions Location: Indoor: Heating Cooling Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75 M Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5 Dry bulb (°F) -15 88 Infiltration: Daily range F) - 19 (M) Method Simplified Wet bulb(' ) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 3 (Average) Component Btuh/ft2 Btuh % of load Walls 7.0 19912 45.6 Glazing 31.2 4860 11.1 Doors 24.6 1867 4.3 Ceilings 1.9 5996 13.7 Floors 1.9 5996 13.7 Infiltration 1.8 5051 11.6 Ducts 0 0 Piping 0 0""~° Humidification 0 0 Ventilation 0 0 - Adjustments 0 G'az' Total 43681 100.0 EMORN • Component Btuh/ft2 Btuh % of load Walls 1.0 2769 21.0 11 -.1 "s Glazing 20.7 3236 24.5 Doors 7.3 550 4.2 Ceilings 1.1 3425 25.9 Floors 0 0 0 Infiltration 0.1 311 2.4 Ducts 0 0 Ventilation 0 0 Internal gains 2920 22.1 Glazing Blower 0 0 Adjustments 0 ailing. Total 13211 100.0 Latent Cooling Load = 1288 Btuh Overall U-value = 0.044 Btuh/ft2-°F WARNING: window to floor area ratio = 4.9% - less than 5%. wrightsoft° Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 104550, Ca W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 2 Component Constructions Job: Toll 3 Plex rl ~ltSOft~ Date: Jul 19, 2010 Medina By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com Project Design Conditions Location: Indoor: Heating Cooling Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 19 (M) Method Simplified Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 3 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ft' Btu[Vft'-°F ft2-°F/Btuh Btuhlff Btuh Btuh/ft' Btuh Walls -rte. 12E-Osw: Frm wall, vnl ext, 1/2" wood shth, r-19 cav ins, 1/2" n 215 0.068 19.0 5.77 1241 1.08 232 gypsum board int fnsh, 2"x6" wood frm e 440 0.068 19.0 5.77 2540 1.08 476 „ se 26 0.068 19.0 5.77 149 1.08 28 - s 178 0.068 19.0 5.77 1028 1.08 192 w 504 0.068 19.0 5.77 2910 1.08 545 all 1363 0.068 19.0 5.77 7868 1.08 1473 15B-8s3c-2: Bg wall, heavy dry or light damp soil, concrete wall, r-8 n 227 0.072 8.0 8.00 1817 0.83 190 ins, 8" thk e 468 0.072 8.0 8.09 3788 0.88 410 se 58 0.072 8.0 8.09 466 0.88 50 s 234 0.072 8.0 8.09 1894 0.88 205 w 504 0.072 8.0 8.09 4079 0.88 441 all 1491 0.073 8.0 8.08 12044 0.87 1295 Partitions (none) Windows 2 glazing, dr outr, air gas, vnl frm mat, dr innr, 1/4" gap, 1/4" thk: 2 n 64 0.350 0 29.7 1902 15.0 963 glazing, dr outr, air gas, vnl frm mat, dr innr, 1/4" gap, 1/4" thk n 52 0.350 0 29.7 1545 15.0 782 se 12 0.350 0 29.7 357 50.3 603 s 12 0.570 0 48.4 581 33.3 400 s 16 0.350 0 29.7 475 30.5 488 all 156 0.350 0 31.2 4860 20.7 3236 Doors 11 P0: Door, mtl pur core type a 28 0.290 10.5 24.6 689 7.25 203 se 20 0.290 10.5 24.6 488 7.25 144 s 28 0.290 10.5 24.6 689 7.25 203 all 76 0.290 10.5 24.6 1867 7.25 550 tea. Ceilings 16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 ceil ins, 5/8" 3210 0.022 44.0 1.87 5996 1.07 3425 gypsum board int fnsh -4 j-t wri9htsoft°, Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:45:50 WAVVnghtsoft HVAC\7bll 3 Plex.rup Calc= MJ8 Orientation = N Page 3 Floors 21A-24t: Bg floor, heavy dry or light damp soil, tile flr fnsh 1605 0.025 0 2.12 3407 0 0 " 21 B-20t: Bg floor, heavy dry or light damp soil, prm int ins cov, r-5 1605 0.019 3.0 1.61 2589 0 0 ins wrightsaft Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:45:50 ACCK W:\WnghtsoftHVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 4 Project Job: Toll 3 Plex wrightsoft- Summary Date: Jul 19, 2010 Medina By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com Project Information For: Notes: Design Information Weather: Minneapolis/St. Paul, MN, US Y~ - Winter Design Conditions Summer Design Conditions Outside db -15 °F Outside db 88 °F Inside db 70 °F Inside db 75 °F Design TD 85 °F Design TD 13 °F Daily range M Relative humidity 50 % Moisture difference 28 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 43681 Btuh Structure 13211 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 43681 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 12260 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 3 (Average) Structure 1288 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 3210 3210 Equipment latent load 1288 Btuh. Volume (ft3) 26483 26483 Air changes/hour 0.13 0.05 Equipment total load 13548 Btuh Equiv. AVF (cfm) 56 23 Req. total capacity at 0.70 S H R 1.5 ton' Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade Trane Trade XB13 Model TUC1B060A9361A* Cond 4TTB3018A1 GAMA ID 164847 Coil 4TX F H 0 1 8AS 3+ * D Y060 R 9V3 ARI ref no. 1052010 Efficiency 92.1 AFUE Efficiency 11.2 EER, 13.3 SEER Heating input 60000 Btuh Sensible cooling 12320 Btuh Heating output 56000 Btuh Latent cooling 5280 Btuh Temperature rise 89 °F Total cooling 17600 Btuh Actual air flow 587 cfm Actual air flow 587 cfm Air flow factor 0.013 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Printout certified byACCA to meet all requirements of Manual J 8th Ed. wrightsoft° Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:45:50 t „CP4 W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 2 AED Assessment Job: Toll 3 Plex wi`IghtSO'~#~' Date: Jul 19, , 201 2010 a Medina By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com Project Information For Design Conditions Location: Indoor: Heating Cooling Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 19 (M ) Wet bulb (°F) - 72 Wind speed (mph) 15.0 7.5 Test • forAdequate Exposure Diversity Hourly Glazing Load 6,000 5,500--- 5,000-- 4,500- 4,000-- , 3,500-- o 3,000-- 2,500-- 2,000-- 1,500-- 1,000-- 500-- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day .~..a. / Hourly / Average AED limit ` Maximum hourly glazing load exceeds average by 25.6%. - Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh , -ff4- wrightsof - Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:45:50 , K W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc = MJ8 Orientation = N Page 2 wrightsoft., Right-J® Worksheet Job: Toll 3Plex Medina Date: Jul 19, 2010 By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheafing.com , 1 Room name Medina Medina LH 2 Exposed wall 342.7 ft 171.3 ft „a 3 Ceiling height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 1605.0 ft 5 Room area 3210.0 ft' 1605.0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Btuh/fV-°F) (Btuh/ft~ or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 'sW 12E-Osw 0 068 n 0.00 0.00 0 0 0 0 0 0 0 IG 2 glazing, clr outr, 0.350 n 0.00 0.00 0 0 0 0 0 0 0 0 1D 11PO 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 n 0.00 0 00 0 0 0 0 0 0 0 0 11 ~--G 2 glazing, clr outr, 0 350 n 0 00 0.00 0 0 0 0 0 0 0 0 1 D 11P0 0 290 n 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 n 5.77 1.08 279 215 1241 232 279 215 1241 232 ~G 2 glazing, clr outr, 0.350 n 29.72 15.04 64 0 1902 963 64 0 1902 963 W 15B-8s3c-2 0.100 n 8.00 0.83 279 227 1817 190 0 0 0 0 „ G 2 glazinq, clr outr, 0 350 n 29.72 15.04 52 0 1545 782 0 0 0 0 W 15B-8s3c-4 0.100 n 0.00 0,00 0 0 0 0 0 0 0 0 VG 2 glazing, clr outr, 0.350 n 0.00 0,00 0 0 0 0 0 0 0 0 W 1513-8s3c-6 0.100 n 0.00 0.00 0 0 0 0 0 0 0 0 W 1513-8s3c-6 0.100 n 0.00 0.00 0 0 0 0 0 0 0 0 I G 2 glazing, clr outr, 0.350 n 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0 068 e 0.00 0.00 0 0 0 0 0 0 0 0 1G 2 glazinq, clr outr. 0.350 e 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 e 0.00 0.00 0 0 0 0 0 0 0 0 k--G 2 glazing, clr out;, 0.350 e 0.00 0.00 0 0 0 0 0 0 0 0 1 D 11 PO 0,290 e 0.00 0.00 0 0 0 0 0 0 0 Q W 12E-Osw 0 068 e 5.77 1.08 468 440 2540 476 468 440 2540 476 I D 11PO 0.290 e 24.62 7.25 28 28 689 203 28 28 689 203 W 1513-8s3c-2 0.100 e 8.09 0.88 468 468 3788 410 0 0 0 0 W 1513-8s3c-4 0100 e 0.00 0.00 0 0 0 0 0 0 0 0 M W 1513-8s3c-6 0.100 e 0.00 0.00 0 0 0 0 0 0 0 0 W 1513-8s3c-6 0100 e 0.00 0.00 0 0 0 0 0 0 0 0 G 2 glazinq clr outs 0 350 e 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 se 5.77 1.08 58 26 149 28 58 26 149 28 G 2 glazing, clr outr, 0.350 se 29.72 50.28 12 0 357 603 12 0 357 603 t-D 11PO 0.290 se 24.62 7,25 20 20 488 144 20 20 4881 144 W 1513-8s3c-2 0 100 se 8 09 0.88 58 58 466 50 0 0 0 0 W 12E-Osw 0.068 s 0,00 0.00 0 0 0 0 0 0 0 0 I---G 2 glazing, clr outr, 0.350 s 0.00 0.00 0 0 0 0 0 0 0 0 I D 11 PO 0.290 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 0.00 0.00 0 0 0 0 0 0 0 0 " ~---G 2 glazing, clr outr, 0.350 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D 11 PO 0.290 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 5.77 1.08 234 178 1028 192 234 178 1028 192 I-G 1 D-c2ov 0.570 s 48.39 33.32 12 0 581 400 12 0 561 400 ~-G 2 glazing, clr outr, 0.350 s 29.72 30.51 16 0 475 488 16 0 475 488 1D 11PO 0.290 s 24.62 7.25 28 28 689 203 28 28 689 203 W 156-8s3c-2 0.100 s 8 09 0.88 234 234 1894 205 0 0 0 0 W 1513-8s3c-4 0.100 s 0.00 0.00 0 0 0 0 0 0 0 0 W 15B-8s3c-6 0.100 s 0.00 0.00 0 0 0 0 0 0 0 0 W 5B-8s3c-6 0100 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 0.00 0.00 0 0 0 0 0 0 0 0 l-G 2 glazing, clr outr, 0.350 w 0.00 0.00 0 0 0 0 0 0 0 0 I D 11 PO 0.290 w 0.00 0.00 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 0.00 0.00 0 0 0 0 0 0 0 0 L-G 2 glazing, clr outr. 0.350 w 0.00 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 38630 9980 19454 6190 12 a) Infiltration 5051 311 2755 170 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 4 920 Appliances/other 2000 2000 Subtotal (lines 6 to 13) 43681 13211 22209 9280 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 43681 13211 22209 9280 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load 43681 13211 22209 9280 Air required (cfm) 587 587 298 412 Printout certified byACCA to meet all requirements of Manual J 8th Ed. a=}+ w.:gt,tsorie° Right-Suite@ Universal 7.1.17 RSU11308 2013-Mar-21 10:4550 <CA W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 3 wrightsoft Right-JO Worksheet Job: Toll 3 Plex Medina Date: Jul 19, 2010 By: Ray N Welter Heating Co 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.velterheafing.com 1 Room name Medina Basement 2 Exposed wall 171.3 ft 3 Ceiling height 9.0 ft heat/cool 4 Room dimensions 1.0 x 1605.0 ft 5 Room area 1605.0 ft' Ty Construction U-value Or HTM Area (ft~ Load Area Load number (Btuh/ft2_°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw 0.068 in 0.00 0.00 0 0 0 0 l-G 2 glazing, clr outr, 0.350 n 0.00 0.00 0 0 0 0 I D 11 PO 0.290 in 0.00 0.00 0 0 0 0 W 12E-OSw 0-068 in 0.00 0 00 0 0 0 0 11 ~-G 2 glazing, clr outr. 0.350 n 0.00 0.00 0 0 0 0 ID 11 PO 0 290 n 0.00 0.00 0 0 0 0 W 12E-0sw 0.068 n 5.77 1.08 0 0 0 0 L G 2 glazing, clr outr, 0.350 n 29.72 15.04 0 0 0 0 W 1513-8s3c-2 0-100 n 8.00 0-83 279 227 1817 190 -G 2 glazing, clr outr, 0 350 n 29.72 15-04 52 0 1545 782 W 1513-8s3c-4 0.100 in 0.00 0.00 0 0 0 0 -G 2 glazing, clr outr, 0.350 in 0.00 0.00 0 0 0 0 W 15B-8s3c-6 0 100 n 0.00 0 00 0 0 0 0 W 156-8s3c-6 0.100 in 0.00 0.00 0 0 0 0 IG 2 glazing, clr outr, 0.350 n 0.00 0.00 0 0 0 0~ W 12E-0sw 0-068 e 0.00 0-00 0 0 0 0 t-G 2 glazinq, clr outr. 0-350 e 0 00 0.00 0 0 0 0 W 12E-Osw 0.068 e 0.00 0.00 0 0 0 0 ~-G 2 glazing, cir outr, 0.350 e 0.00 0.00 0 0 0 0 1 D 1WO 0,290 e 0.00 0,00 0 0 0 0 W 12E-Osw 0.068 e 5.77 1-08 0 0 0 0 L-D 11 PO 0.290 e 24.62 7.25 0 0 0 0 W 1513-8s3c-2 0.100 e 8.09 0.88 468 468 3788 410 W 1513-8s3c-4 0 100 e 0.00 0 00 0 0 0 0 W 15B-8s3c-6 0.100 e 0.00 0.00 0 0 0 0 1513-8s3c-6 0-100 e 0.00 0-00 0 0 0 0 -G 2 glazinq clr outr, 0.350 e 0.00 0.00 0 0 0 0 UV 12E-OSw 0.068 se 5.77 1.08 0 0 0 0 ~-G 2 glazing clr outr, 0.350 se 29.72 50.28 0 0 0 0 t-D 11 PO 0.290 se 24.62 7.25 0 0 0 0 W 1513-8s3c-2 0.100 se 8.09 0 88 58 58 466 50 W 12E-Osw 0.068 s 0.00 0.00 0 0 0 0 ~-G 2 glazing, clr outr, 0.350 s 0.00 0.00 0 0 0 0 1 D 11P0 0.290 s 0.00 0.00 0 0 0 0 W 12E-Osw 0.068 s 0.00 0.00 0 0 0 0 ~-G 2 glazing, clr outr, 0.350 s 0.00 0.00 0 0 0 0 1 -D 11 PO 0 290 s 0.00 0.00 0 0 0 0 W 12E-Osw 0.068 S 5.77 1.08 0 0 0 0~ 1-G 1 D-c2ov 0.570 s 48.39 33.32 0 0 0 0 4^ I-G 2 glazing clr outr 0.350 s 29.72 30.51 0 0 0 0 TM 1-D 11P0 0.290 s 24.62 7.25 0 0 0 0 W 1513-8s3c-2 0 100 s 8.09 0 88 234 234 1894 205 W 1513-8s3c-4 0.100 s 0.00 0.00 0 0 0 0 W 15B-8s3c-6 0.100 s 0.00 0.00 0 0 0 0 - W 15B-8s3c-6 0.100 s 0.00 0.00 0 0 0 0 W 12E-OSw 0.068 w 0.00 0.00 0 0 0 0 ~-G 2 glazing, clr outs. 0.350 w O00 0.00 0 0 0 0 ` I D 11 PO 0.290 w 0 00 0.00 0 0 0 0 W 12E-Osw 0,068 w 0.00 0.00 0 0 0 0 t-C 2 glazing clr Gutr, 0.350 w 0.00 0.00 0 0 0 0 6 c) AED excursion 0 Envelope loss/gain 19176 3790 12 a) Infiltration 2296 141 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 21472 3931 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 21472 3931 15 Duct loads -0% 0% 0 0 Total room load 21472 3931 Air required (cfm) 288 175 Printout certified bvACCA to meet all requirements of Manual J 8th Ed. " -f + w::gr,tsorYC° Right-Suite® Universal 7.1.17 RSU11308 2013-1 10:45:50 AC;C k W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation = N Page 4 .Q Duct System Summa Job: Toll 3 Plex wI ightso to Date: Jul 19, 2010 Medina By: Ray N Welter Heating Co -F 4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com ..A. Project Information For: Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply / return available pressure 0.00/0.00 in H2O 0.00/0.00 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 587 cfm 587 cfm Total effective length (TEL) 0 ft Supply Branch-Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat] Ln (ft) Ln (ft) Trunks Medina Basement h 1311 96 58 0 0 Ox 0 ShMt 0 0 Medina Basement-A h 1310~ 96 58 0 O~ Ox 0 ShMt 0 0 -7 =11' Medina Ba ement-B h 1310 96 58 0 I 0 Ox 0 I ShMt 0 0 Medina LH c 3093 99 137 0 0 0x0 ShMt 0 0 Medina LH-A c 3093 99 137 0 0 Ox 0 ShMt 0 0 1 Medina LH-B I c 30931 991 137 1 01 01 Ox 0 1 ShMt 1 0 1 0 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 587 587 0 0 0 0 Ox 0 ShMt M -F 4- wriightsort- Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 10:45:52 C W:\Wrightsoft HVAC\Tbll 3 Plex.rup Calc= MJ8 Orientation = N Page 2 s LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: ~ e A L e- z~ ~4 avq DATE OF SURVEY: ~~/1J3 LATEST REVISION: m a~ c t U O z Q DOCUMENT STANDARDS ❑ ❑ . Registered Land Surveyor signature and company ❑ ❑ . Building Permit Applicant ❑ ❑ • Legal description ref` ❑ ❑ . Address ❑ ❑ • North arrow and scale ❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ❑ ❑ . Directional drainage arrows with slope/gradient % /e ❑ ❑ • Proposed/existing sewer and water services & invert elevation ❑ ❑ • Street name ❑ ❑ . Driveway (grade & width - in R/W and back of curb, 22' max.) ❑ ❑ . Lot Square Footage ' ❑ ❑ . Lot Coverage ELEVATIONS Existin ❑ ❑ • Property corners ❑ ❑ . Top of curb at the driveway and property line extensions ❑ ❑ • Elevations of any existing adjacent homes ❑ ❑ . Adequate footing depth of structures due to adjacent utility trenches ❑ ❑ • Waterways (pond, stream, etc.) Proposed ❑ ❑ • Garage floor ❑ ❑ . Basement floor fd ❑ ❑ • Lowest exposed elevation (walkout/window) ❑ ❑ . Property corners ❑ ❑ . Front and rear of home at the foundation 'JZ PONDING AREA (if applicable) ❑ ❑ . Easement line ❑ ❑ • NWL ❑ ❑ • HWL ❑ f~ ❑ • Pond # designation ❑ / ❑ . Emergency Overflow Elevation ❑ Pond/Wetland buffer delineation Y I . Shoreland Zoning Overlay District Y Conservation Easements DIMENSIONS ❑ ❑ . Lot lines/Bearings & dimensions ❑ ❑ . Right-of-way and street width (to back of curb) /e ❑ ❑ . Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ❑ ❑ • Show all easements of record and any City utilities within those easements ,2-' ❑ ❑ . Setbacks of proposed structure and sideyard setback of adjacent existing structures -~p ❑ ❑ . Retaining wall requirements: Reviewed By: Date-- G:/FORMS/Cert. of Survey Checklist Rev. 3-3-11 Certificate of Survey koTOLL BROTHERS OF 01 2) l 1400 Corporate Center Curve Eagan, MN 55121 1447, 1449, 1451 STEEPLECHASE LANE rJ ' .C 966 \ 66. 3:1 Maximum Slopes ter Retaining Wall Wig 968 0 Be Required ~ 970 973.8 . 972 NORTH "-C 974.1 x 72. "p 974 ^F 9o 974. \ n 974.4 S~ 7 e x975.0 `X; /L.L.VuC~ i 974.6 1 fl Of 0 30 t~ F 74 - 46 gf \ '1-1 t§977.2 ►w FsS 4. Tai p \ N SCALE IN FEET i' oow`O q►' • d 21.2 cv 75 80. f 16.9 1 v; , - - - u)~ K7NDpW. 6 9 O VD0 9 71 .977.4 976.5 I ° 51 i~~,~` ~ll 40#1 056 1 L0#1449 5 1.5 LFEr #057 ' ~ N 6.0 LN BA OKO ' 9715 LOT #05 Jti~.~tao C) M T LOOKO{tT LFE_97 ooyE~1°r l 1.8 T' BASEMENT s@o.7 gA E 0 2 ~Jd1 Oc g location of 5 v ' O and Water stub p - o \ ^9 6.41 K ? sp RLK-Kuuslsto pl \I _ _\J, 4 j GAR GE i AGE r / to 1(o co 74 `F c 4.9 ` 2 9785.00 1 9 80, M. py 1 f ~ GARAGE u E" A 1s.92 o, r_ 20.6 21.p f o o 1f r a F- . C6 h~ 95 S of 90 at. C6 o°I I 0 ~n o9> G)y { ^ +ti 'Mt! 980.5 { 20.6 i 3Z48 5 C) 75.6 r ! O ` > i 7_15.04-81. 1 16 14 7 C 9~s, r ca _ fo o o111 4, Utillty 1- 98 Easement 8 ' 9>S :78.3 S 9y 978• 980.3 f~ 1 ~r \ LO House 1449 & 1451 lookout ( I elevation; = 975.0 I 1447 lookout BENCHMARK r elevation = 976.0 Top Nut Hydrant Lots 1 and 2, Block 3, Steeplechase Elevation = 989.17 feet (NGVD 1988) Prop. San. & Water Inv. elev. = 965.2 per RLK plans dated AREA 7/6/05 Lot 3, Block 2 Area = 21,875 sq. ft. LEGEND Total Condo area = 703,324 sq. ft. 20% Max. Coverage = 140,665 sq. ft. • _ Iron monument found a« _ Drainage Direction Foundation Lot 1, Block 2 6931 sq. ft. o = Offset iron - Prop. 10' contours from grading plan Foundation Lot 2, Block 2 = 6930 sq. ft. - -842- Prop. 2' contours from grading plan Foundation Lot 3, Block 2 = 6930 sq. ft. = Drainage & Utility Easement - = Existing sanitary sewer Foundation Lot 1, Block 6 = 6709 sq. ft. xeooo = Existing Elevation = Existing storm sewer Foundation Lot 2, Block 6 = 6709- sq. ft. = Proposed elevation from grade I - - Existing water Foundation Lot 3, Block 6 = 9073 sq. ft. or development plan O = Sanitary manhole ca = Gate valve Foundation Lot 1, Block 7 = 9074 sq. ft. -840-- Existing 10' contours t} Hydrant Foundation Lot 2, Block 7 = 7106 sq. ft. - 842-- = Existing 2' contours p =flared End Section Foundation Lot 1, Block 8 = 6676 sq. ft. ® = catch Basin Foundation Lot 2, Block 8 = 6815 sq. ft. Foundation Lot 3, Block 8 = 6709 sq. ft. Bearings shown are assumed Foundation tot 4, Block 8 = 6709 sq. ft. Foundation Lot 5, Block 8 = 9072 sq. ft. Foundation Lot 7, Block 8 8879 sq. ft. Foundation Lot 8, Block 8 = 8879 sq. ft. PROPOSED ELEVATIONS PROPOSED ELEVATIONS Total Foundation coverage = 113201 sq. ft. 1447 1449 & 1451 Remaining coverage Available 27464 sq. ft. n t,' Garage floor elev. = 981.0 Garage floor elev. 980.0 CITY OF t~ E A`jAI V Top of block elev. _ 981.3 Top of block elev. _ 880.3 Lowest floor elev. 972.5 Lowest floor elev. = 971.5 Lot 37 Block 2 Lookout elev. = 976.0 Lookout elev. 975.0 WED C~ T E E P L E C H©C~. DRAWN: JAG CHECKED: HDN V / \1J .By Drawing File: 700\718-L3-B2 DWG Date Project Na. 2006-408-L OF EAGAN EAGAN ENGINEERING DEPT Subject to easements of record, if any. I hereby certify that this survey, plan or report was prepared by 6100 Blue Circle Dr. me or under my direct supervision and that I am a duly Licensed Suite 100 Minnetonka, MN. Land Surveyor under the laws of the State of Minnesota. RLK WnMSTo L~ Phone: (952) 933-0972 4/1/2013 Fax: (952) 933-1153 Henry D. Nell on MN Licen a No. 17255 Date www,.rik-kuusisto.com Revised: 7-5-07 City ments 6110 Blue Circle Dr. Suite #100 -Minnetonka, MN. 55343 Apr 01, 2013 12:14pm G: aToll Brothers- Survey02006-408-LOdwq 0700 ORevised Lot Certificates oBlock 2 - Lot 302006-408-L 718 Block 2 Lot 3.dwq 4,111° C!tyofEaafl 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 MAT t 0 2013 Use 6t L or BLACK Ink For Office Use Permit #: Permit Fee: 1,1 L� V Date Received: 5P0 .1 Staff: 2013 FIRE SUPPRESSION SYSTEMS PERMIT APPLICATION* Date: ZU / 3 Site Address: / L�,7 /4 -/e -C7 CJ � Chc-' �S Tenant: ' 'P )cam 4c---, ' Suite #: J Property Owner Name: 7—Y P Phone: Address / City / Zip: Applicant is: Owner Contractor Type of Work Description of work: Construction Cost: Estimated Completion Date: Contractor Name: &MAN i'- rife - raf+et' it eA �„ License #: C -c15 Address: 51 ' A A,Ae jAzJkt_ City: '{`. S41-4.4-1 State: Zip: 55103 Phone: tS%' eiS6 / f ® Contact: Email: FIRE PERMIT TYPE Sprinkler System (# of heads, ') Standpipe WORK TYPE New Addition Fire Pump _ Alterations Remodel _ Other: _ _ Other: DESCRIPTION OF WORK: _ Commercial Residential Educational FEES $55.00 Minimum/x $1 million, please call for Surcharge / Z oC Contract Value $ / / 3 �� 1% *If the project valuation is over = $ C / 3, YO Permit Fee _ $ 5.00 Surcharge* .$ '( l TOTAL FEE 3/4" Displacement Fire Meter - $245.00 = $ Fire Meter = $ TOTAL FEE 2 complete sets of drawings and specifications, cut sheets on materials and components to be used I hereby apply for a Fire Suppression System permit and acknowledge that the information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Minnesota Building/Fire Codes; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x eJ Applicant's Panted Name Applicant's Signature FOR OFFICE USE REQUIRED INSPECTIONS ►static April 3, 2014 71311 Architecture Keith Pew Steeplechase of Eagan - Carriages 1440 Steeplechase Lane Eagan, MN 55122 RE: TBI Lots #57 Dear Keith: --r Ui ll- �t24_42 Z -110 -472: - For your window opening at the rear of lot #57, replacing the (2) 1 3/4" X 93/4"LVL's at the Rear Master Bedroom Window over the (2) 2862 windows with (3) 2X10's is structurally adequate. Do not hesitate to contact me with any further questions. Sincerely, Toll Brothers, Inc. I hereby certify that this pian, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the Slate at Minnesota. Print Name: jgYLVIA E. SEN .$ENY Signature: �1 Date 7•11 License ft Sylvia E. Senseny, AIA Studio Leader MN License #48401 CC: Richard Kittredge SS/HM SECR_1tr0046 AO 85478 ERN DIVISION 25( (iisitar 1 oad 11 Horsham, PA 19044 0 (2151 29.3-531)(1n 1A\: (215) 203-5314 Pi-IILADELI'1tIA ri ORLANDO Li DALLAS ;t `�1nlf `;Brothel;, CO3 fI IA'l' *Toll Architecture January 10, 2014 Jon Henson Steeplechase of Eagan — Carriages c/o MN Division Office 14260 23rd Ave N. Plymouth, MN 55447 RE: TBI Lot #057 Dear Jon: i 1449 Steeplechase Lane 62- ri At TBI Lot 57, the opening in the rear wall of the basement below the Great Room needs to be shifted several inches to avoid interference with an interior finished wall behind the stair. I have no issue with shifting the basement window and its header and jack/king studs to the avoid missing the finished framed wall near the stair. If you have any questions or concerns, please do not hesitate to call. Sincerely, Toll Brothers, Inc. Lisa M. Grosse, P.E. Assistant Director of Engineering MN License#44835 CC: Sylvia Senseny LMG/sf SECR 1tr0040 AO 80082 ztic i, i,;r � n rL 1':dsprlcp a_ zd by 7, Y or ul A -r r f .`'3 e v 7.iiro . ,L, -.“..i _. ..,....c:-..,, ... t... _ 1.{rr f� �.s d 1._.. . %Jc`.t Aida :;:., / 3'y .. tL �� � 1�1fd17_v 1fl7Y1J33 EASTERN DIVISION 250 Gibraltar- Road • Horsham, PA 19044 ■ (215) 293-5300 • FAX: (215) 293-5314 PHILADELPHIA • ORLANDO • DALLAS A `Toll `Brothers COMPANY April 3, 2014 Keith Pew Steeplechase of Eagan - Carriages 1440 Steeplechase Lane Eagan, MN 55122 RE: TBI Lots #57 Dear Keith: 144 9 R The headers on your loll/ 57 framing plan shows (2) 1 3/4 x 9 %2" dropped LVLs above the rear Great Room window openings. It is acceptable to substitute (2) 2x10 headers above each window in lieu of the Lvl's. Do not hesitate to contact me with any further questions. Sincerely, Toll Brothers, Inc. hereby cenuy ural usb N,u,l, spettcation, or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota. Print Name: YLVIA E. SENSENY Signature: Date W y License it 48401 Sylvia E. Senseny, AIA Studio Leader MN License 1#48401 CC: Richard Kittredge SS/HM SECR Itr0045 AO 85478 clty of E���� _ Address: 1449 Steeplechase Lane Zip: 55122 Permit#: 109966 The following items were/were not completed at the Final Inspection on: ��,��i� i �a��,11 " v��`� i�u � � ri I�� m P �II� �aY2 . . � �����g���P4����5°��!`t�tPp�J4i���� ?`'�lii r ��i" � � ��mple�� In+��►r��lete >���n, � , �fi�r"����s ��� � ��.-;;,rv Ro�ii��«�.�. � 'i����lt��������i����ll�u�.��� Final grade - 6"from siding Permanent steps —Garage � Permanent steps — Main Entry Permanent Driveway � Permanent Gas v Retaining Wall or 3:1 Max Slope (/ Sod / Seeded Lawn � Trai� ; Cur� Jam�ge Porch 1� Lower Level Finish � Deck /f Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. � Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: v G:\Building Inspections\FORMS\Checklists • RECEJl y ZP r For Office Use I 6 9 %, � • 2U1� :::::ee.' E AG NAPR 01 �6(G'e)' ' Date Received: I ' / 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD: (651)454-8535 I FAX: (651)675-5694 Staff: /46 buildinqinspectionscityofeaqan.com J 2019 RESIDENTIAL BUILDING PERMIT APPLICATION Date: Site Address: /Unit#: Name: �Q-f//// -ixat, Phone: ( ) 231-<n VQ CL- Resident/ Owner Address/City/Zip: / gTO-e pchWf-e �� E?Viit/v r�� .5&722_ Applicant is: Owner Contractor Type of Work Description of work: In/g h S Q fl1e,,7L /-f v`P Construction Cost: /5e , .20 Multi-Family Building: (Yes /No_2C) Company: Contact: Contractor Address: City: State: Zip: Phone: Email: License#: Lead Certificate#: If the project is exempt from lead certification, please explain why: (3$9 COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes, date and address of master plan: Licensed Plumber: Phone: Mechanical Contractor: Phone: Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeacian.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to •rt without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approve' plans.j' 11/41 # I 114") le/<1xAGI'd cant's Printed Name Applicant's 'gnature DO NOT WRITE BELOW THIS LINE I i`I S-k- rlecli7)-L 6 L 6 , / - -----(7e- - / SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration(Multi) Multi Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of Plex >0 Lower Level Pool _ Accessory Building WORK TYPES New P Interior Improvement Siding _ Demolish Building* Addition _ Move Building _ Reroof _ Demolish Interior Alteration — Fire Repair _ Windows _ Demolish Foundation Replace _ Repair Egress Window Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION Valuation Occupancy TW1 -.3 MCES System Plan Review Code Edition (fl ( zc) SAC Units (25%_ 100% SP ) Zoning PJ City Water Census Code Stories _ Booster Pump _ #of Units Square Feet PRV #of Buildings _ Length Fire Suppression Requireduired Type of Construction lr; Width REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final I C.O. Required Footings (Addition) ei0 Final I No C.O. Required Foundation Foundation Before Backfill jO HVAC_Service Test Gas Line Air Test_Hood Roof:_Ice &Water _Final Pool:_Footings _Air/Gas Tests _Final gp Framing 14 30 Minutes 1 Hour Drain Tile Fireplace:_Rough In Air Test _Final Siding:_Stucco Lath _Stone Lath Brick_EFIS p Insulation Windows Sheathing Retaining Wall:_Footings_Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression:_Rough In_Final Braced Walls Erosion Control Shower Pan „/l � Other: Reviewed By: � D PT) ", /� k cl� , Building Inspector RESIDENTIAL FEES Base Fee /Z s,� S�- /� e) Zv, Surcharge -" rl c 1.4 es ,jn7?, r2,00(4 Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit& Surcharge Treatment Plant Radio Meter Read Copies TOTAL Page 2 of 3 I- For Office Use t r s a Permit#: E AG A NkEGEJVL - ._. Permit Fee: ;.e(./ 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 DEC 2 0 2019 Date Received: /02- ' -// (651)675-5675 I TDD: (651)454-8535 I FAX: (651)675-5694 Staff: buildinginspectionsc citvofeagan.com 2019 RESIDENTIAL PLUMBING PERMIT APPLICATION Date: `aV'-� Site Address: 1_ I Yq S+e--(pt.e CI14St C 1'1 Tenant: • Suite#: Resident/Owner Name: 1�`� �1) v I V�t ISA ) Phone: Address/City/Zip:__ /1 % SfeQ / 40 c-/A0-4( QC Gy Name: �'r .-f) -C,+ PI 144 01 V)JC License#: NIA (3(0 5313 Address: 6-270 e1/4,(1146t4,-/ et. V� 5 City: Co%/ ta, Sy-ad e yI Contractor State: /i N Zip: 5-S-6/4" Phone: 6'57-.276 9.?Jv Contact: SeF- 6ST-2 n-1710 Email: i < AL1 ky,L lw 61414 ti ,cOki Type of Work ew _Replacement _Repair Rebuild _Modify Space _Work in R.O.W. Description ofwork:345ekl J $hocalt- 4-1UGtv1� l��+v 1z wcSI Tu4 Tankless Water Heater Lawn Irrigation( RPZ/_PVB) Standard Water Heater Add Plumbing Fixtures ( Main/_Lower Level) Description Water Softener Description: Septic System- _New Abandonment Connection to City Water from Well RESIDENTIAL FEES t $60.00 Water Heater, Water Softener, or Water Heater and Softener(includes State Surcharge) $60.00 Lawn Irrigation (includes State Surcharge) $60.00 New fixtures, adding or removing piping (includes State Surcharge) $60.00 Septic System Abandonment $100.00 New Residential (fee collected with Building Permit) $115.00 New Septic System (includes County fee and State Surcharge) $60.00 Connecting to City Water from Well*+ $290 for Meter and $190 for Radio Read = $540 *Sewer&Water Permit also required for connection charges TOTAL FEES $ CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.org You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x VIAL Applicant's Printed Name App' n ' ignature Page 1 of 2 FOR OFFICE USE Reviewed By: Date: Required Inspections: Under Ground Rough-In Air Test Gas Test Final Meter Related Items: Meter Size Radio Read Manometer Staff: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 TDD: (651)454-8535 FAX: (651)675-5694 buildinginspections ancitvofeaoan.com Page 2 of 2 Ko (ig4s l For Office Use On kk-4-C Permit#: /U�6- :,)/--7-s ; � �� i��� /��� cj ,� Permit Fee: EAGAN 1 Staff: n E C E I V E Payment Recvd: %es No 3830 PILOT KNOB ROAD i EAGAN, MN 55122-1810 (651)675-5675 I TDD:(651)454-8535 I FAX:(651)67 61E8 2 4 2020(a� L Plans: Electronic Paper J buildinginspectionscityofeagan.com 2019 FIRE SUPPRESSICSYSTE -•PERMIT APPLICATION Date: .4. -119)- Site Address: I qLH Ste. -e_at AAQ_ Tenant: ..CML_ Oi -s4-1„_ Suite#: 0 Requirements: 2 complete sets of drawings and specifications, cut sheets on materials and components I w Name: < 9,_ Phone: Property Owner Address/City/Zip: Applicant is: Owner Contractor Type of Work Description of work: Aci6, ;:d w„ F.A wkt,li Veri k) So -C ; 1- -6..1,--r/.5 e 'L,i,► prS'(�1,1 , q Construction Cost: G CO Estimated Completion Date: /7 4i -2O2e) Ayajj Name: Summit Fire Protection License#: C-075 Contractor Address: 575 Minnehaha Ave W City: St. Paul State: MN Zip: 55103 Phone: 651-251-1880 Contact: A r•eui Vii.'4-14- Email: sprinklerpermit@summitcous.com FIRE PERMIT TYPE WORK TYPE L rinkler System(#of heads 9 ) New _Addition Fire Pump _Standpipe ?°Alterations Remodel Other: Other: DESCRIPTION OF WORK: Commercial T Residential _Educational FEES Contract Value$ l-7( x.01 $60.00 Permit Fee Minimum Surcharge=Contract Value x$0.0005 =$ Permit Fee If the project valuation is over$1 million, please call for Surcharge =$ ` `J Surcharge $100.00 Residential New(includes State Surcharge) =$ CPQ%• �3---- TOTAL FEE 3/4"Fire Meter-$290.00 =$ Fire Meter Radio Read(required with Fire Meters)-$190 =$ TOTAL FEE You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www cityofeagan.comisubscribe. I hereby apply for a Fire Suppression System permit and acknowledge that the information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan and with the Minnesota Building/Fire Codes;that I understand this is not a p- it,but only an application for a permit,and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which req 'gs review and ap v of pia s.' A dr-- Applicant's Printed Name Applic.nt's Signature FOR OFFICE USE REQUIRED INSPECTIONS Hydrostatic Flow Alarm Drain Test Rough In Trip Pump Test Central Station ?‹.i Final Conditions of Issuance: Permit Reviewed by: Date: 2 I OK / 070026 cam' PERMIT City of Eagan Permit Type:Building Permit Number:EA179793 Date Issued:10/19/2022 Permit Category:ePermit Site Address: 1449 Steeplechase Lane Lot:3 Block: 2 Addition: Steeplechase Of Eagan PID:10-72540-10-057 Use: Description: Sub Type:Reroof Work Type:Replace Description:Includes Skylight Census Code:434 - Residential Additions, Alterations Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Please print pictures of ice and water protection and leave on site. If water damage is encountered, please call (651) 675-5675 to schedule a site visit to verify the extent of the damage. Any repairs must be inspected prior to covering. The inspector will determine if an additional permit will be required to repair the water damage. Valuation: 5,000.00 Fee Summary:BL - Base Fee $5K $118.00 0801.4085 Surcharge - Based on Valuation $5K $2.50 9001.2195 $120.50 Total: This permit shall be null and void if work does not start within 180 days of issuance, or if work is suspended for 180 days or more after started. I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Kevin & Mary Ann Mcgrath 1449 Steeplechase Ln Eagan MN 55122 Parkway Custom Construction Llc 1303 S Frontage Rd Suite 199 Hastings MN 55033 (651) 480-3797 Applicant/Permitee: Signature Issued By: Signature