1459 Steeplechase Lane
j ocAg5q /DO- Use BLUE or BLACK Ink
100 ~J^ForOfficeU,rsle~-/---------
j Permit City of Eap g4D 3 .1
I Permit Fee. 1
3830 Pilot Knob Road 11
Eagan MN 55122 Date Received:
Phone: (651) 675-5675 I I
Fax: (651) 675-5694_ 1 Staff: i
2013 RESIDENTIAL BUILDING PERMIT APPLICATION
Site Address: 1451 5rt_EPL4 Gel&f iL tA-)K- Unit
Name: TOLL FOIZAT11)-A-Cl I J L.. Phone: SOS l' 3110 s'0 b0 1
Resident/ J
Owner Address/ City/ Zip: 1 `f a Sr6)ePu_r c44roc f_ [.)*jF_ 0 )ScAtw lp .1111U14 1'5" 1AA
Applicant is: _X_Owner /X Contractor L-" (3--L
Type of Work Description of work: NEW V S r A ic1-1Jrt4%- 3' Vw+ 1 r r0We).4i/K)E SLAP b.
"Z- Multi-Family Building: (Yes _ / No )
Company: TOLX. $120784AAS , ;Pjc- Contact; TON Hw-so J
Contractor Address: l `'l qO SIB Pt-+~ t.111'At (AW& L City: FSA/ oAPJ
Q
State: _MA) Zip: Phone: G0S/•3l6S=0%001 (OAK.) ~iJ:)-SV? 61,01 CA"-
License 1&(--%193 1,* ll;0 P. Lead Certificate d 1 A
If the project is exempt from lead certification, please explain why: (see Page 3 for additional information)
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan?
_Yes X No If yes, date and address of master plan:
Licensed Plumber: SPA #AJ%,, P%_-JA4$#0J4,o, Phone: T\3'
Mechanical Contractor: IZAy. H. bALr A N%1hCr Phone: lot?. 615- tos%al
Sewer & Water Contractor: bsm EXC*ilkr o-) Phone: tp'r l " 46o-
NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of
the information may be classified as non-public if you provide specific reasons that would permit the City to
conclude that they are trade secrets.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours
before you intend to dig to receive locates of underground utilities. www.gogherstateonecall.orq
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
x Too NIEwjto•.j
Applicant's Printed Name
Page 1 of 3
1 q5
DO NOT WRITE BELOW THIS LINE j 5
SUB TYPES
Foundation _ Fireplace _ Porch (3-Season) _ Storm Damage
Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family)
Multi _ Deck _ Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi)
A01 of Plex _ Lower Level Pool _ Miscellaneous
_ Accessory Building
WORK TYPES
New _ Interior Improvement _ Siding Demolish Building*
Addition _ Move Building _ Reroof Demolish Interior
Alteration Fire Repair _ Windows _ Demolish Foundation
Replace _ Repair _ Egress Window _ Water Damage
Retaining Wall *Demolition of entire building - give PCA handout to applicant
DESCRIPTION
Valuation OccupancyMCES System
Plan Review Code Edition 4-~s%r*7 SAC Units
(25%_ 100%9 Zoning City Water
Census Code Stories * Booster Pump
# of Units 31 Square Feet PRV
# of Buildings- Length- Fire Sprinklers
Type of Construction Width !
REQUIRED INSPECTIONS
Footings (New Building) Meter Size:
Footings (Deck) C Final / C.O. Required
Footings (Addition) Final / No C.O. Required
Foundation HVAC _ Gas Service Test Gas Line Air Test
Drain Tile Other:
Roof: -Ice & Water Final Pool: Footings Air/Gas Tests -Final
Framing Siding: -Stucco Lath Stone -Brick
Fireplace: _X Rough In VAir Test (,.Final Windows
* Insulation Retaining Wall Footings Backfill Final
Sheathing Radon Control
Sheetrock Erosion Control
Reviewed By: Building Inspector
RESIDENTIAL FEES
Base Fee J J41
Surcharge v` 1 s
Plan Review
17
MCES SAC ! f 1 ; p I
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant -
Copies
F
TOTAL'
a ; Pag 2 of
Date: 3/22/2013 Revision Date: 3/22/2013 New Construction
Site Information
Address 1: 1 LJ5 1 9e-ef ~ C~?a s-e L -ice Project Steeplechase of Eagan
Address 2: Wayzata slab plan Lot: #50 Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Ray N. Welter Heating MN Contractor License
Contact Person: Joe
Office Ph: 612-825-6867 Fax: Cell Ph:
Address 1: 4637 Chicago Ave. So.
City: Minneapols State: MN. Zip Code: 55407
House Details
Square Feet: 2629 sq. ft. Avg. Ceiling Ht: 12.2 Number of Bedrooms: 3
ft.
Ventilation : Exhaust
Total Ventilation Capacity : 140 cfm.
Minimum Continuous Ventilation :60cfm.
Continuous Ventilation Provided: Exhaust: 60 cfm
Intermittent ventilation satisfied by OTHER exhuast appliance.
Combustion Appliance Combustion Zone 1
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Combustion Zone 2
Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 60,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): Yes Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 110
Make-Up Air
No Make-Up Air Required by Code
Combustion Air
Combustion Zone One Round Rigid Required: 5 inches or Insulated Flex: 6 inches
Combustion Zone Two: Minimum Combustion Air Requirements Met.
Applicant Name (print); lfe~L T e %~s Signature/Date:
Code Official (print): Signature/Date/-
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1
9 (DOI 9SE
3 n = I o X „ c tv~?
g m ° c o a.
5' 3 a Li I c H ~ o
Z y
3 _ lD n
~ h i i C o o ~ w
N G ~ ~ ~ ,ti a~i O
d o o
o o
6 0 A 3 a rt'
tu IV
1 c e 3 1 a
m o' rc a
0 19
oil
CL CL
0 r+
Ir V,
0 4D
dPZ
t. o. Z,
r ~ Z
a C ~ h ti t r
fli-
❑ w
e
1
N
Load Short Form Job: Toll 3 Plex
wrightSofto Date: March 21 2013
lot 50 By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.melterheatng.com
Project Information
For:
Design Information
Htg Clg Infiltration
Outside db (°F) -15 88 Method Simplified
Inside db (°F) 70 75 Construction quality Tight
Design TD (°F) 85 13 Fireplaces 3 (Average)
Daily range - M
Inside humidity 30 50
Moisture difference (gr/lb) 32 28
HEATING EQUIPMENT COOLING EQUIPMENT
Make Trane Make Trane
Trade Trane Trade XB13
Model TUC1B060A9361A* Cond 4TTB3024A1
GAMA ID 164847 Coil 4TXCB025AS3+*UX2B080AFV3
ARI ref no. 1245266
Efficiency 92.1 AFUE Efficiency 11.2 EER, 13.3 SEER
Heating input 60000 Btuh Sensible cooling 15680 Btuh
Heating output 56000 Btuh Latent cooling 6720 Btuh
Temperature rise 70 °F Total cooling 22400 Btuh
Actual air flow 747 cfm Actual air flow 747 cfm
Air flow factor 0.015 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
ROOM NAME Area Htg load Clg load HtgAVF CIgAVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
RH Main 1927 31528 13921 459 631
Room9 983 19795 2561 288 116
lot 50 2910 51323 16482 747 747
Other equip loads 0 0
Equip. @ 0.93 RSM 15295
Latent cooling 1112
L
TOTALS 2910 51323 16408 747 747
Printout certified byACCA to meet all requirements of Manual J 8th Ed.
-P- wrightsoft" Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 16:02:15
ACCK W:\Wrightsoft HVAC\7bll 3 Plex.rup Calc= MJ8 Orientation=NE Page 1
Toll Architecture
April 15, 2013
Richard Kittredge
Steeplechase of Eagan - Carriages
1442 Steeplechase Lane
Eagan, MN 55122
RE: TBI Lots #050, 051, 052
Dear Rick,
For TBI Lots #050, 051 and 052, I have reviewed the construction documents for structural
integrity. I find no exceptions to the roof framing, floor framing, and foundations including "tall
wall" assemblies and lateral stability.
If you have any questions or concerns, please do not hesitate to call.
Sincerely,
Toll Brothers, Inc.
ccrt76! t%s%t 11h s p;,m, $ e4 i.
fi.oatiur~ cr rcron was prepar;d b
K' 10 or under r- iv y . ti.ct su t:;-visi
"d that I am a a-dy I-. nsed
I x 'Ssi al E- er under the
I of t"e Late e+ r .t, .`esota.
♦ 'Y'
IN x
si twe: e
Date / 1 1 .cer,~e #
Lisa M. Grosse, P.E.
Assistant Director of Engineering
MN License#44835
CC: Sylvia Senseny
LMG/sy
SECR_1tr0031
AO 65818
EASTERN, D1VtS10N
250 Gibraltar Road Horsham, PA 19044 (215) 293-5300 FAX: 0153 293-5314
PHILADELPHIA ORLANDO DALLAS
A Toll t e COMPzINY
moll Architecture 10
April 23, 2013
Jon Henson
Steeplechase of Eagan - Carriages
1442 Steeplechase Lane
Eagan, MN 55122
RE: TBI Lots #050, 051, 052
Dear Jon,
For TBI Lots 50-52, the attached exterior footing detail is an acceptable alternative to the trench
footing details 1/SLD-1 and 9/SLD-1 indicated on the foundation plan.
If you have any questions or concerns, please do not hesitate to call.
Sincerely,
Toll Brothers, Inc.
f I.elr*y v:ztify t;;.- 2 this pl.:,A speci-
{'x='j x', or rppor, ;t it s k r p+'trW by
/7It; U? I:i ; C'i li'?'t r?i-:ii 8 2*T I ~15ion
r r, the
ta.
M. 0.3 TROEZSE
r1~i3ilsi 4'.
C:ttG) Z~ HI-se #440'35
Lisa M. Grosse, P.E.
Assistant Director of Engineering
MN License#44835
CC: Sylvia Senseny
LMG/sy
SECR 1tr0034
AO 67403
EASTERN WISION
250 Gibraltar Road Horsham, PA 19044 (215) 293-5300 FAX: (215) 293-5314
PHILADELPHIA ra ORLANDO r DALLAS
A lo-11 cBrothers OO 1II'f1 / Y
-
wrightsoft~ Load Multizone Summary Report Job: Toll 3 Plex
Date: March 21 2013
By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com
Infiltration Summary
Heating Cooling
ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM
ft3 cfm Btuh/ft2 ft3 drn Btuh/ft2
lot 52 20748 0.13 44 1.8 20748 0.05 17 0.1
lot 51 19068 0.14 43 1.8 19068 0.05 17 0.1
lot 50 20292 0.13 43 1.8 20292 0.05 17 0.1
Entire House 60108 0.13 130 1.8 60108 0.05 50 0.1
Load and AVF Summary
ROOM NAME Area Htg load Clg load HtgAVF C1gAVF
ft2 Btuh Btuh cfm cfm
LH MAIN 1973 30534 14497 485 643
Rooml 997 20240 3679 322 163 a
lot e52 dina up 2970 541 50773
20046 1817 2374 I 807 2 99 807 113
Medina LH 1605 21105 10466 315 500
lot 51 3146 41151 12840 I 613 613
RH Main 1927 31528 13921 459 631
Room9 983 19795 2561 288 116
lot 50 2910 51323 16482 747 747
Entire House 9026 143247 46161 2167 2167
AA- wrighrtsoft.., Right-SuiteO Universal 7.1.17 RSU11308 2013-Mar-21 15:37:26
ACa W:\WrightsoftHVAC\7b113Plex.rup Calc=MJ8 Orientation=NE Page1
Building Analysis Job: Toll 3 Plex
N/Ir!9htSo$,"' IOt 5~ Date: March 21 2013
By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com
Project Information
For:
Design Conditions
Location: Indoor: Heating Cooling
Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75 w--
Elevation: 837 ft Design TD (°F) 85 13
Latitude: 45°N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5 w
Dry bulb (°F) -15 88 Infiltration:
Daily range (°F) - 19 (M) Method Simplified
Wet bulb(' ) - 72 Construction quality Tight
Wind speed (mph) 15.0 7.5 Fireplaces 3 (Average)
•
Component Btuh/ft2 Btuh % of load
Walls 6.3 17767 34.6
Glazing 29.7 6181 12.0
Doors 24.6 1551 3.0
Ceilings 1.9 3599 7.0
Floors 9.5 18312 35.7
Infiltration 1.8 3913 7.6
Ducts 0 0
Piping 0 0
Humidification 0 0
Ventilation 0 0 G'az'"e
Adjustments 0 c~ e=
Total 51323 100.0
Component Btuh/ft2 Btuh % of load
Walls 0.7 2048 12.4 "`ama Ga'°= "
Glazing 40.3 8379 50.8 °"ef
Doors 7.3 457 2.8 FooCeilings 1.1 2056 12.5
Floors 0.7 1394 8.5
Infiltration 0.1 227 1.4
Ducts 0 0 Celli"9=
Ventilation 0 0
Adjustments 0 Glazing
Internal gains 1920 11.6
Blower 0 0 D.-
Total 16482 100.0
Latent Cooling Load = 1112 Btuh
Overall U-value = 0.105 Btuh/ft2-°F
Data entries checked.
wrightsoft Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 15:37:26
CCK W:\WrightsoftHVAC\Toll 3 Plex.rup Calc= MJ8 Orientation=NE Page 1
....rte
_•-.rte:,
Component Constructions Job: Toll3 Plex
Wrlght$Oft~` Date: March 21 1 2013
lot 50 By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com
Project • •
For:
Design Conditions
Location: Indoor: Heating Cooling
Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75,
Elevation: 837 ft Design TD (°F) 85 13
Latitude: 45°N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5
Dry bulb (°F) -15 88 Infiltration:
Daily range (°F) - 19 (M) Method Simplified
Wet bulb (°F) - 72 Construction quality Tight
Wind speed (mph) 15.0 7.5 Fireplaces 3 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft' BtuW'-°F ft'-°FBtuh Bturff Btuh Btuh/ft' Btuh
Walls
12E-0sw: Frm wall, vnl ext, 1/2" wood shth, r-19 cav ins, 1/2" ne 471 0.068 19.0 5.77 2719 1.08 509
gypsum board int fnsh, 2"x4" wood frm se 243 0.068 19.0 5.77 1403 1.08 263
sw 564 0.068 19.0 5.77 3256 1.08 610
nw 195 0.068 19.0 5.77 1126 1.08 211
all 1473 0.068 19.0 5.77 8504 1.08 1593
15B-8s3c-6: Bg wall, heavy dry or light damp soil, concrete wall, r-8 ne 281 0.073 8.0 6.87 1932 0.31 87
ins, 8" thk, 1/2" gypsum board int fnsh se 378 0.073 8.0 6.96 2632 0.35 132 -
sw 297 0.073 8.0 6.96 2068 0.35 104
nw 378 0.073 8.0 6.96 2632 0.35 132
all 1334 0.073 8.0 6.94 9263 0.34 456
Partitions
(none)
Windows
2 glazing, dr outr, air gas, vnl frm mat, dr innr, 1/4" gap, 1/4" thk: 2 ne 84 0.350 0 29.7 2496 38.2 3208
glazing, dr outr, air gas, vnl frm mat, dr innr, 1/4" gap, 114" thk ne 16 0.350 0 29.7 475 38.2 611 Nam.„,
se 24 0.350 0 29.7 713 50.3 1207
sw 12 0.350 0 29.7 357 50.3 603
nw 72 0.350 0 29.7 2139 38.2 2750
all 208 0.350 0 29.7 6181 40.3 8379 -
Doors
11 P0: Door, mtl pur core type ne 21 0.290 10.5 24.6 517 7.25 152
se 21 0.290 10.5 24.6 517 7.25 152
nw 21 0.290 10.5 24.6 517 7.25 152
all 63 0.290 10.5 24.6 1551 7.25 457
Ceilings
16B-44ad: Attic ceiling, asphalt shingles roof mat, r-44 veil ins, 5/8" 1927 0.022 44.0 1.87 3599 1.07 2056
gypsum board int fnsh
4f4- wrightsoft Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 153727
ACCk W:\Wrightsoft HVAC\7bll 3 Plex.rup Calc= MJ8 Orientation=NE Page 1
Job: Toll 3 Plex
rj tS(` Project Summary Date: March 21 2013
lot 50 By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com
Project • •
For:
Notes:
Design Information
Weather: Minneapolis/St. Paul, MN, US
Winter Design Conditions Summer Design Conditions
Outside db -15 OF Outside db 88 OF
Inside db 70 OF Inside db 75 OF
Design TD 85 OF Design TD 13 OF
Daily range M
Relative humidity 50 % -
Moisture difference 28 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 51323 Btuh Structure 16482 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh -
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 51323 Btuh Use manufacturers data n
Rate/swing multiplier 0.93
Infiltration Equipment sensible load 15295 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 3 (Average) Structure 1112 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ftz) 2910 2910 Equipment latent load 1112 Btuh
Volume (ft3) 20292 20292
Air changes/hour 0.13 0.05 Equipment total load 16408 Btuh
Equiv. AVF (cfm) 43 17 Req. total capacity at 0.70 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade Trane Trade XB13
Model TUC1B080A9421A* Cond 4TTB3024A1
GAMA ID 164848 Coil 4TXCB025AS3+*UX2B080AFV3
ARI ref no. 1245266
Efficiency 92.1 AFUE Efficiency 11.2 EER, 13.3 SEER n
Heating input 80000 Btuh Sensible cooling 15680 Btuh µ
Heating output 74000 Btuh Latent cooling 6720 Btuh
Temperature rise 93 OF Total cooling 22400 Btuh .
Actual air flow 747 cfm Actual air flow 747 cfm
Air flow factor 0.015 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.94
Printout certified byACCA to meet all requirements of Manual J 8th Ed.
tgltsaft' Right-SuiteO Universal 7.1.17RSU11308 2013-Mar-2115:3727
ACCK W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation=NE Pagel
AED Assessment Job: Toll 3 Plex
W rlght$o'PtW Date: March 21
21 2013
lot 50 By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: wVwv.mlterheating.com
Project Information
For:
Design Conditions
Location: Indoor: Heating Cooling
Minneapolis/St. Paul, MN, US Indoor temperature (°F) 70 75
Elevation: 837 ft Design TD (°F) 85 13
Latitude: 45°N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.5 _
Dry bulb (°F) -15 88 Infiltration:
Daily range (°F) - 19 (M )
Wet bulb (°F) - 72
Wind speed (mph) 15.0 7.5
Test • • e q u ate • •
Hourly Glazing Load
10,000T
9,000 i
8'00u-r-
+ ;
7,000
M 6,000 H
II
N w rn
O
5,000
0~.
4,000
3,000--'r
2,000
1,0007-
0
f
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
/ Houdy / Average / AED limit
Maximum hourly glazing load exceeds average by 15.6%.
Zone has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
wrightsoft` Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 15:37:27
14- Ad- AX ,K W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientaton = NE Pagel
~ti
wrightsoft, Right-JO Worksheet Job: Toll 3Plex
dot 50 Date: March 21 2013
By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com
1 Room name lot 50 RH Main
2 Exposed wall 342.0 ft 192.0 ft
3 Ceiling height 9.0 ft 9.0 ft heat/cool
4 Room dimensions 1.0 x 1927.0 ft
5 Room area 2910.0 ft2 1927.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area (M Load
number (Btul (Btu ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12E-Osw 0.068 tie 0.00 0.00 0 0 0 0 0 0 0 0
1 G 2;glazing, clr outr. 0,350 ne 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 ne 5.77 1.08 576 471 2719 509 576 471 2719 509
I-G 2 glazing, clr outr, 0.350 ne 29.72 38.19 84 0 2496 3208 84 0 2496 3208
11 1-D 11 PO 0.290 ne 24.62 7.25 21 21 517 152 21 21 517 152
W 12E-0sw' 0 068 ne 0.00 0.00 0 0 0 0 0 0 0 0
W 15B-8s3c-6 0.100 ne 6.87 0.31 297 261 1932 87 0 0 0 0 R
L-G 2 glazinq, clr outs, 0 350 ne 29.72 38.19 16 0 475 611 0 0 0 0«-
W 12E-Osw 0.068 se 0.00 0.00 0 0 0 0 0 0 0 0-
G 2 glazing, clr outr, 0.350 se 0.00 0.00 0 0 0 0 0 0 0 0
1-13 11 PO 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 se 5.77 1.08 288 243 1403 263 288 243 1403 263
, G 2 glazing, cir outr, 0.350 se 29.72 50.28 24 0 713 1207 24 0 713 1207
I D 11 PO 0.290 se 24.62 7.25 21 21 517 152 21 21 517 152 -
W 12E-Osw 0.068 se 0.00 0.00 0 0 0 0 0 0 0 0 -
i-G 2 glazing, clr outr, 0.350 se 0.00 0.00 0 0 0 0 0 0 0 0
I D 11 PO 0.290 se 0.00 0.00 0 0 0 0 0 0 0 0
W 156-8s3c-6 0.100 se 6.96 0.35 378 378 2632 132 0 0 0 0
L--G 2 glazinq, Clr outr, 0 350 se 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0,068 s 0.00 0.00 0 0 0 0 0 0 0 0
1- G 2 glazing. CIF outr. 0.350 s 0.00 0.00 0 0 0 0 0 0 0 0
1D 11 PO 0.290 s 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0 068 sw 0 00 0 00 0 0 0 0 0 0 0 0
k-G 2 glazing clr outr 0 350 sw 0.00 0.00 0 0 0 0 0 0 0 0
~D 11 Po 0.290 sw 0.00 0 00 0 0 0 0 0 0 0 0
W 12E-Os w 0.068 sw 5.77 1 08 576 564 3256 610 576 564 3256 610
-G 2 glazing clr outr, 0.350 sw 29.72 50.28 12 0 357 603 12 0 357 603
W 12E-Osw 0.068 sw 0 00 0 00 0 0 0 0 0 0 0 0
-D 11 PO 0.290 sw 0 00 0 00 0 0 0 0 0 0 0 0
W 1513-8s3c-6 0.100 sw 6,96 0.35 297 297 2068 104 0 0 0 0
1-G 2 glazing, cir outr, 0.350 sw 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0 068 nw 0.00 0.00 0 0 0 0 0 0 0 0
-----G 2 glazing, clr outr, 0.350 nw 0.00 0.00 0 0 0 0 0 0 0 0 v>
L-D 11 PO 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 nw 5,77 1.08 288 195 1126 211 288 195 1126 211
--G 2 glazing, clr outr, 0.350 nw 29.72 38.19 72 0 2139 2750 72 0 2139 2750
1D 11PO 0.290 nw 24.62 7.25 21 21 517 152 21 21 517 152
W 12E-Osw 0 068 nw 0.00 0.00 0 0 0 0 0 0 0 0
1G 2 glazinq, clr outr. 0.350 nw 0.00 0.00 0 0 0 0 0 0 0 0
W 1513-8s3c-6 0.100 nw 6.96 0.35 378 378 2632 132 0 0 0 0
C 1613-30ad 0 032 0.00 0.00 0 0 0 0 0 0 0 0
C 1613-44ad 0.022 1.87 1.07 1927 1927 3599 2056 1927 1927 3599 2056
F 19A-0bscp 0 295 9.41 1 42 983 983 9249 1394 0 0 0 0~
F 20P-301 F 22C-5Qpm 01 135 36 .036 _ 90.00 0.00 944 94 9060 0
0 944 94 9063 0
6 c) AED excursion 0 -53
Envelope loss/gain 47410 14335 28423 11821
12 a) Infiltration 3913 227 3105 180
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 4 920 4 920
Appliances/other 1000 1000 _
Subtotal (lines 6 to 13) 51323 16482 31528 13921
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 51323 16482 31528 13921
15 Duct loads 0% 0% 0 0 -0% 0% 0 0
Total room load 51323 16482 31528 13921
Air required (cfm) 747 747 459 631
Printout certified bvACCA to meet all requirements of Manual J 8th Ed.
wr.gniesort° Right-Suit Universal 7.1.17 RSU11308 2013-Mar-21 15:37:27
W:\Wrightsoft HVAC\Toll 3 Plex.rup Calc= MJ8 Orientation=NE Pagel
wrightsoft, Right-J® Worksheet Job: Toll 3 Plex
lot 50 Date: March 21 2013
By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: www.welterheating.com .
1 Room name Room9
2 Exposed wall 150.0 ft rv
3 Ceiling height 9.0 ft heat/cool
4 Room dimensions 1.0 x 983.0 ft
5 Room area 983.0 ft' -
Ty Construction U-value Or HTM Area (ft') Load Area Load
number (Btuh/W-°F) (Btu ft) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12E-Osw 0.068 ne 0.00 0.00 0 0 0 0
1-G 2 glazing, clr outr, 0.350 ne 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 ne 5.11 1.08 0 0 0 0
I-G 2 glazing, clr outr, 0.350 ne 29.72 38.19 0 0 0 0
11 1D 11PO 0.290 ne 24.62 7.25 0 0 0 0
W` 1211-0sw 0.068 ne 0.00 0.00 0 0 0 0
W 15B-8s3c-6 0.100 ne 6.87 0.31 297 281 1932 87
I G 2 glazinq clr 0utr. 0 350 ne 29.72 38.19 16 0 475 611
W 12E-Osw 0.068 se 0.00 0.00 0 0 0 0
G 2 glazing. clr outr, 0.350 se 0.00 0.00 0 0 0 0
F__D 11P0 0.290 se 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 se 5.77 1.08 0 0 0 0
~G 2 glazing, clr outr, 0.350 se 29.72 50.28 0 0 0 0
~D 11 PO 0 290 se 24.62 7.25 0 0 0 0
W 12E-Osw 0.068 se 0.00 0.00 0 0 0 0
I-G 2 glazing, clr outr, 0.350 se 0.00 0.00 0 0 0 0
1D 11P0 0.290 se 0.00 0.00 0 0 0 0
W 15B-8s3c-6 0 100 se 6.96 0.35 378 378 2632 132
1G 2 glazinq. Clr outr 0 350 se 0 00 0.00 0 0 0 0
W 12E-Osw 0.068 s 0.00 0.00 0 0 0 0
~--G 2 glazing. clr outr 0.350 s 0.00 0.00 0 0 0 0 r...
I D 11PO 0.290 s 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 sw 0 00 0 00 0 0 0 0
--G 2 glazing. clr outr. 0.350 sw 0.00 0.00 0 0 0 0
L-D 11 PO 0.290 sw 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 sw 5.77 1.08 0 0 0 0 ..t
G 2 glazing. clr outr, 0.350 sw 29.72 50.28 0 0 0 0
W 12E-Osw 0.068 sw 0.00 0.00 0 0 0 0
V-D 11 PO 0 290 sw 0.00 0 00 0 0 0 0
AI 1513-8s3c-6 0.100 sw 6.96 0.35 297 297 2068 104 ..r«.:.
G 2glazing, clroutr. 0-350 sw 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 nw 0.00 0.00 0 0 0 0
~-G 2 glazing clr outr 0 350 nw 0.00 0.00 0 0 0 0
I-D 11 PO 0 290 nw 0.00 0.00 0 0 0 0
W 12E-Osw 0.068 nw 5.77 1.08 0 0 0 0
{-G 2 glazing, clr outr, 0.350 nw 29.72 3819 0 0 0 0
1 -D 11 PO 0.290 nw 24.62 7.25 0 0 0 0
W 12E-Osw 0.068 nw 0.00 0.00 0 0 0 0
1 G 2 glazinq, clr Dutr, 0.350 nw 0.00 0.00 0 0 0 0
W 513-8s3c-6 0.100 nw 6.96 0.35 378 378 2632 132
C 1613-30ad 0.032 0.00 0.00 0 0 0 0
C 1613-44ad 0.022 1.87 1.07 0 0 0 0
F 19A-Obscp 0.295 9.41 1.42 983 983 9249 1394
F 20P-30t 0.035 0.00 0.00 0 0 0 0
F 22C-5tpm 1.135 96.36 0.00 0 0 0 0
6 c) AED excursion 53
Envelope loss/gain 18987 2514
12 a) Infiltration 808 47
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13) 19795 2561
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 19795 2561
15 Duct loads -0% 0% 0 0
Total room load 19795 2561
Air required (cfm) 288 116
Printout certified byACCA to meet all requirements of Manual J 8th Ed.
Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 15:37:27
ACC~k W:\Wrightsoft HVAC\7bll 3 Plex.rup Calc= MJ8 Orientation = NE Page 2
Job: Toll 3Plex
+ wrghtSoft, Duct System Summary Date: March 21 2013
lot 50 By:
Ray N Welter Heating Co
4637 Chicago Ave S, Minneapolis, MN 55407 Phone: 612-825-6867 Fax: 612-825-2303 Web: owvw.vvelterheating.com
-61
millift
Project In
formation
For:
Heating Cooling
External static pressure 0 in H2O 0 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0 in H2O 0 in H2O
Supply/ return available pressure 0.00/0.00 in H2O 0.00/0.00 in H2O
Lowest friction rate 0 in/100ft 0 in/100ft
Actual air flow 747 cfm 747 cfm
Total effective length (TEL) 0 ft
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv r
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk w.
RH Main c 3481 115 158 0 0 Ox 0 ShMt 0 0
RH Main-A c 3480 115 158 0 0 Ox 0 ShMt 0 0
RH Main-B c 3480 115 158 0 0 Ox 0 ShMt 0 0
RH Main-C c 3480 115 158 0 0 Ox 0 ShMt 0 0
Rooms h 854 96 39 0 0 Ox 0 ShMt 0 0 -
Roorn9-A In 853 96 39 0 O~ Ox 0 ShMt
Rooms-B h 853 6 39 0 0 Ox0 ShMt I 0 0
Return Branch Detail Table
Grill Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb4 Ox 0 747 747 0 0 0 0 Ox 0 ShMt
r
,
-EI.}- wrights4D t, Right-Suite® Universal 7.1.17 RSU11308 2013-Mar-21 15:37:28
ACC~k W.\Wrightsoft HVAC\Jbll 3 Plex.rup Calc= MJ8 Orientation=NE Page 1
I
,
Level 2
7.; ,m
P,LH
I
r;
Job Toll 3 Plex Ray N Welter Heating Co Scale: 1 : 176
Performed for: Page 1
4637 Chicago Ave S Right-Suite® Universal
Minneapolis, MN 55407 7.1.17 RSU11308
Phone: 612-825-6867 Fax: 612-825-2303 2013-Mar-21 15:37:45
www.welterheating.com W:\Wrightsoft HVAC1Toll 3 Plex.rup
level 3
'~rQC~Ma as ism .
n -a.na -G ~ .rn b :r
`~-100 cfrn „
-gnaoi+:
.d?aMgn.
Job Toll 3 Plex Ray N Welter Heating Co Scale: 1 : 176
Performed for: Page 2
4637 Chicago Ave S Right-Suite® Universal
Minneapolis, MN 55407 7.1.17 RSU11308
Phone: 612-825-6867 Fax: 612-825-2303 2013-Mar-21 15:37:45
F www.welterheating.com W:\Wrightsoft HVAC\Toll 3 Plex.rupr
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
PROPERTY LEGAL: "e- AO
DATE OF SURVEY: T//3
LATEST REVISION:
d
a~
c
t
V
O z Q DOCUMENT STANDARDS
❑ ❑ • Registered Land Surveyor signature and company
❑ ❑ • Building Permit Applicant
❑ ❑ . Legal description
-.01 ❑ ❑ . Address
❑ ❑ . North arrow and scale
❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.)
❑ ❑ . Directional drainage arrows with slope/gradient %
_.e' ❑ ❑ • Proposed/existing sewer and water services & invert elevation
❑ ❑ . Street name
❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.)
H' ❑ ❑ • Lot Square Footage
❑ ❑ . Lot Coverage
ELEVATIONS
Existing
❑ ❑ • Property corners
❑ ❑ . Top of curb at the driveway and property line extensions
❑ ❑ . Elevations of any existing adjacent homes
❑ ❑ . Adequate footing depth of structures due to adjacent utility trenches
❑ ❑ • Waterways (pond, stream, etc.)
Proposed
❑ ❑ . Garage floor
❑ 'z D * Basement floor
❑ ❑ . Lowest exposed elevation (walkout/window)
~e1 ❑ ❑ . Property corners
❑ ❑ • Front and rear of home at the foundation
PONDING AREA (if applicable)
❑ ❑ . Easement line
fd ❑ ❑ . NWL
JZ ❑ ❑ • HWL
~z ❑ ❑ . Pond # designation
❑ ,,B' ❑ . Emergency Overflow Elevation
❑ ❑ • Pond/Wetland buffer delineation
Y AV • Shoreland Zoning Overlay District
Y Conservation Easements
DIMENSIONS
❑ ❑ Lot lines/Bearings & dimensions
❑ ❑ • Right-of-way and street width (to back of curb)
❑ ❑ . Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
❑ ❑ . Show all easements of record and any City utilities within those easements
❑ ❑ • Setbacks of proposed structure and sideyard setback of adjacent existing structures
❑ ❑ . Retaining wall requirements:
Reviewed By: Date
G:/FORMS/Cert. of Survey Checklist Rev. 3-3-11 N
Certificate of Surve J TOLL BROTHERS
OF 1400 Corporate Center Curve
/f • ~
1459, 1461, 1463 STEEPLECHASE LANE Eagan, MN 55121
9139 2
4 '?t!1l11 slopes 91~
C:b
S~
:.g bull W
641 :-,,j4u►red '.98
NORTH 00 D(` 6~
978.
6 LP 56.1 O%
7 J j moo, , 6~~°~'V1~~S, \ NWL=967.5 9 SP'~
G ~o°~~ryoo 'i'~, Cor " ~'o \°9a s l 0~~, HWL=970.8 f
980.
ask°:
SCALE IN FEET
s \ 8 <'o
A iii
~P ° i'.h°° c' 9cF > 6 G~tiy~yAs~ Xg13g / '6, QP~\ \ • • .
N -0110 A,
'dio
. cF /
s \ \ O O /
Yb 91~3
* TALL
F, I&b
zz1z5 f ~,\~`g~-•-- Z E ETER CONTROL
/91 J911
\ \ o
X9~S e
F
s,
BENCHMARK r
Prop. San. & Water Inv.
Top
elevation 962.0
Block 3Nut Hydrant Lots 1 and 2 INSTALL EEZOSIO11~
Block Steeplechase ~
Elevation 989.17 feet (NGVD 1988) BLAN.N[ C f Qrz SOD Per RLK plans dated 7/6/05
AREA
Lot 1, Block 2 Area = 17,021 sq. ft. LEGEND
Total Condo area = 703,324 sq. ft.
20% Max. Coverage = 140,665 sq. ft. • = Iron monument found = Drainage Direction
Foundation Lot 1, Block 2 = 6931 sq. ft. a Offset iron Prop. 10' contours from grading plan
Foundation Lot 2, Block 2 = 6930 sq. ft. - -842- = Prop. 2' contours from grading plan
Foundation Lot 3, Block 2 = 6930 sq. ft. Drainage & Utility Easement = Existing sanitary sewer
Foundation Lot 1, Block 6 = 6709 sq. ft. xaw.o = Existing Elevation -<<- Existing storm sewer
Foundation Lot 2, Block 6 = 6709 sq. ft. = Proposed elevation from grade - I - = Existing water
Foundation Lot 3, Block 6 = 9073 sq• ft. or development plan O Sanitary manhole
=
Foundation Lot 1, Block 7 = 9074 sq. ft. ®840- = Existing 10' contours oa Gate valve
~ = Hydrant
Foundation Lot 2, Block 7 7106 sq. ft. ®842- = Existing 2' contours p = Flared End Section
Foundation Lot 1, Block 8 = 6676 sq. ft.
Foundation Lot 2, Block 8 = 6815 sq. ft. Bearings shown are assumed
Foundation Lot 3, Block 8 = 6709 sq. ft.
Foundation Lot 4, Block 8 = 6709 sq. ft.
Foundation Lot 5, Block 8 = 9072 sq. ft. PROPOSED ELEVATIONS
Foundation Lot 7, Block 8 = 8879 sq. ft. 1459, 1461, & 1463
Foundation Lot 8, Block 8 = 8879 sq. ft.~
Total Foundation coverage = 113201 sq. ft. Garage floor elev. = 973.8
Remaining coverage Available = 27464 sq. ft. Top of block elev. 974.4 By
Lowest floor elev. 974.4
Date
CITY OF E A G A N MGM IwGiNEL%NC DM
Lot 1 , Block 2
STEEPLECHASE DRAM: JAG CHECKED:.. HDN
Drawing File: 700\718-L1-B2.DWG
OF EAGAN Project No. 2006-408-L
Subject to easements of record, if any.
I hereby certify that this survey, plan or report was prepared by 6100 Blue Circle Dr.
me or under my direct supervision and that I am a duly Licensed Suite 100
Land Surveyor under the laws of the State of Minnesota. RLK Minnetonka, MN.
fro LTD Phone: (952) 933-0972
4/242013 Fax: (952) 933-1 153
Henry elson, MN License No. 17255 Date vvvvw.rIk-kuusisto.com
6110 Blue Circle Dr. • Suite #100 • Minnetonka, MN. 55343
Apr 24, 2013 12:40pm
1,1--17nn,rVDnDTnn1 0n17 CVDnDT10-!..n.1 1 f`...1if1....1.... nDl....l. 0 - I-+ 1 10nna_An12-1 719 DI....I. 0 - I -1 .d..,..
411°
C!tyofEa&ail
3830 Pilot Knob Road
Eagan MN 55122
Phone: (651) 675-5675
Fax: (651)675-5694
Use BLUE or BLACK Ink
For Office Use
0144 -
Permit #:
Permit Fee: 1 (.0 03
Date Received: 1 q 1 i
Staff:
2013 FIRE SUPPRESSION SYSTEMS PERMIT APPLICATION*
Date: �'- �-- 73 Site Address: )t L i/o
Tenant:
��Gp�J/�G�ufSC.
Suite #:
Property Owner
Name: /_e pi,2 t C k Cc S e Phone:
Address / City / Zip: / `/ Z)-5 - / LI (1 - /1-/G -5 S 4-e e,a f 4 C S f Z_Q, •1 2
Applicant is: Owner r / Contractor
Type of.Work
Description of work: /H yd c f 1 /j p f i,., !Cj r 5 1/4/=4e�1 stt1 ✓ovj il pol- kio ►vicef vpi*-
Construction Cost: Estimated Completion Date:
Contralrtr
Name: at mm it Fire -401-10,03/4-1. CAA_ License #: C - 015
J1 J 1I. AAtiA4-.1,0) City: .
Address: �,j101-4,44
State: _ Zip: 5 jIO5 Phone: (oS% ort. /'Q
Contact: Email:
FIRE PERMIT TYPE
prinkler System (# of
heads )
Standpipe
WORK TYPE
New Addition
Fire Pump
_
/
Alterations Remodel
Other:
Other:
DESCRIPTION OF WORK:
Commercial /0 Residential
Educational
_
FEES
$55.00 Minimum
$1 million, please call for Surcharge
Contract Value $ if 8.°C) x 1%
*If the project valuation is over
= $ / 5 a 0 Permit Fee
,
= $ 5.00 Surcharge*
_$ /63.G0 TOTAL FEE
3/4" Displacement Fire Meter - $245.00
= $ Fire Meter
= $ 16 3 C9 0 TOTAL FEE
. 2 complete sets of drawings and specifications, cut sheets on materials and components to be used
I hereby apply for a Fire Suppression System permit and acknowledge that the information is complete and accurate; that the work will be in
conformance with the ordinances and codes of the City of Eagan and with the Minnesota Building/Fire Codes; that I understand this is not a permit, but
only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the as ' roved plan in the case of work
which re a review and approval of plans.
x ��� `( r tt
Applic nt's Printe ame
x
Applic
nat e
City of Eagan
PERMIT
City of Eaan
Permit Type: Building
Permit Number: EA116703
Date Issued: 10/10/2013
Permit Category: ePermit
Site Address: 1459 Steeplechase Lane
Lot: 1 Block: 02 Addition: Steeplechase Of Eagan
PID: 10-72540-02-010
Use:
Description:
Sub Type: Fireplace Construction Type:
Work Type: Gas Fireplace (new)
Description:
Census Code: 434 - Occupancy:
Zoning:
Square Feet: 0
Comments:
Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to
concealing.
Carbon monoxide detectors are required by law in ALL single family homes.
Fee Summary:
BL - Base Fee $3K
$88.50
Surcharge - Based on Valuation $3K $1.50
0801.4085
9001.2195
Total: $90.00
Contractor:
Hearth And Home Technologies
2700 N. Fairview Ave
Roseville MN 55113
(651) 638-3309
- Applicant -
Owner:
Toll Mn Lp
250 Gibraltar Rd
Horsham PA 19044
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Applicant/Permitee: Signature
Issued By: Signature
Lee Fischer
Manor Concrete Construction, Inc.
11225 90th Ave N
Maple Grove, MN 55369
October 3, 2013
Terry Zelenka
City of Eagan Building Department
3830 Pilot Knob Road
Eagan, MN 55112
Good afternoon Terry,
01)
6 s
I'm writing this letter to confirm that the Monolithic Footings at all three addresses listed below were installed per the
building foundation plan (see attached) at the correct widths, lengths and depths.
Addresses:
1463 Steeplechase
1461 Steeplechase
1459 Steeplechase
I apologize for any inconvenience this may have caused and thank you for understanding and cooperating with us in
this matter.
If you have any questions please contact me at lee@manorconcrete.com or on my cell 612.685.3461.
Sincerely,
Lee Fischer
CONSTRUCTION t$ •
//FOUNDATION !/FIATWORK //MASONRY
11225 90th Avenue N • Maple Grove, Minnesota 55369 • 763-497-5420 • Fax: 763-497-5425
Manor Concrete Construction, Inc.
License #0001222
City of Ekon
Address: 1459 Steeplechase Lane
Zip: 55122
Permit #: 109958
The following items were / were not completed at the Final Inspection on: t Z
Final grade - 6" from siding
Permanent steps — Garage
Permanent steps — Main Entry
Permanent Driveway
Permanent Gas
Retaining Wall or 3:1 Max Slope
Sod / Seeded Lawn
Trail / Curb Damage
Jrrr
Porch
Lower Level Finish
Deck
Fireplace
ry vJt
Pvou(>
• Verify with your builder that roof test caps from the plumbing system have been removed.
• Turn off water supply to the outside lawn faucets before freeze potential exists.
• Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an
irrigation system.
Building Inspector:
/
G:\Building Inspections\FORMS\Checklists