Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
4924 Whispering Way
~m j o---Use BLUE or BLACK Ink --i For Office Use I q g Permit L1 I City of EaEdH 3 I Permit F ~i q~ 3 eC , _ 3830 Pilot Knob Road D - I Eagan MN 55122 I Date Received: Phone: (651) 675-5675 I Fax: (651) 675-5694 1 Staff: 1 - 1 2013 RESIDENTIAL ~IJILDING PERMIT APPLICATION ~l Date: J Site Address: 1 p Unit Name: Phone: Resident/ Owner Address / City / Zip: Applicant is: Owner Contra r l $ r2/ Wt~ I I L Type of Work description of work: t y y l L L L 1Ia Lh, 0-Y1 lnYe a-,.) ~U 4r ~'I Construction Cost: Multi-Family Building: (Yes ! No Company: ontact: . S a 010-V G Contractor Address: aao ► Vtvy: P~uYVC.>V 1 ~ State: Zip: J Pha a:~ q (d - ~bi o - 2)W0 License 22C 0 00 01 W !4 Lead Certificate If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) ~ -/l COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan Issued a permit for a similar plan based on a master plan? " _Yes No If yes, date and address of master Ian: P~utiw~,o(25-L r,, -7 Licensed Plumber Phone: r 4U!~ - I b3A- Mechanical Contractor. 141 c Phone: uool (0 (P ! gob Sewer & Water Contractor. VvItAq W'G Phone: ~~21- -1; 0U 3 - 1 b U J- NOTE. Plans and supporting docume s that you submit are consfdVred to be public information. Portions of the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-OM for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gooherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in confomance the ordina and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to without a that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior worts authorized by a building permit issued in accordance with the Minnesota State B 1 g Code be completed within 180 days of permit issuance. x pt7 Applicant's Printed Name App cant Signature Page 1 of 3 L+1904 wk S DO NOT WRITE BELOW IS LII 1101,03 SUB TYPES _ Foundation _ Fireplace _ Porch (3-Season) _ Storm Damage Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family) _ Multi _ Deck _ Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi) _ 01 of Plex _ Lower Level Pool Miscellaneous Accessory Building WORK TYPES _ New _ Interior Improvement _ Siding _ Demolish Building* _ Addition _ Move Building _ Reroof _ Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation _ Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building give PCA handout to applicant DESCRIPTION Valuation Occupancy MCES System Plan Review Code Edition ou, SAC Units / (25%_ 100% ) Zoning ^1 City Water 1 y Census Code / o l Stories Booster Pump Ald # of Units / Square Feet / $ G ~J PRV 4 ►M # of Buildings ) Length Fire Sprinklers "I"M Type of Construction- Width REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final / C.O. Required Footings (Addition) Final / No C.O. Required Foundation HVAC - Gas Service Test Gas Line Air Test Drain Tile Other: Roof: , llce & Water Final Pool: -Footings -Air/Gas Tests -Final Framing Siding: -Stucco Lath -Stone Lath -Brick Fireplace: Rough In l Air Test Final Windows insulation Retaining Wall: _ Footings _ Backfill _ Final ( Sheathing Radon Control Sheetrock Erosion Control Reviewed By: , Building Inspector RESIDENTIAL FEES L1. /®1 -40 6 /7 Y70 ~ Base Fee 201 2 - / $ f /0 to CP ij- q 7 Al y N o Surcharge 79 vo A, 6 / ,~/►~t c.~j 3i3 / j y A,y,.5 ~ °Z 3 Plan Review 1JY 31 08~ MCES SAC 7 fr ~l City SAC ~ o Utility Connection Charge 3 S&W Permit & Surcharge Treatment Plant A90 31X Copies TOTAL Page 2 of 3 New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a pemmanently visible location ride Date CerfiScate Posted the building. The certificate shall be completed by the builder and shall list mfommation and values of components listed in Table N1101.8. 3/25/13 Mailing Address of the Dwelling or Dwelling Unit city 4924 WHISPERING WAY CAPITANI Eagan, MN m 1-NUMCOMMT"-w Name of Residendal Contractor MN License Number Venneh'em Building Co q2. BC108964 THERMAL ENVELOPE RADON SYSTEM c Type: Check All That Apply Passive (No Fan ) E b Active (With fan and monometer or c 3 ti other system montiormg device ) o a e° > a z ° a w T o Insulation Location a .o c ft U O m o A H 5 Z w w w w 4 j9 Olhes Please Describe Here Below Entire Slab X Foundation Wall R10 X Interior Perimeter of Slab on Grade X Rim Joist (Foundation) R13.4 X Interior Rim Joist (1'c Floor+) R13.4 X Iraetror Wall R19 X Ceiling, flat R44 Ix Ceilin vaulted X Bay Windows or cautilevered areas R43 X X R30 Batt Insul. + 2°SPRAY FOAM Room over gar a FLOOR R43 X X R30 Batt Insul. + T SPRAY FOAM Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Ave. U -Factor (exchides sWi hts & one door) U: 0.30 Not applicable, all ducts located ;conditioned space Solar Heat Gain Coefficient (SHGC): 0.32 R value MECHANICAL SYSTEMS Make-up Air SelectaType Appliances Heating System Domestic Wt. Heater Goa Not required per meck code Fuel Type Natural Gas Electric Electric Passive Manufacturer LENNOX RHEEM LENNOX Powered Interlocked with exhaust device . Model ML193uHO90XP RHaPRO52-21 -036-23 Describe: ~m 88,00(? C 3 TON describe: Ratin or Size stns. GalloHeat 6 5 554 Locati Structure's Calculated Lass: onof ductorsystem: AFUE 93% 13 or HSPF"/o 31,991 Cfin's " round duct OR Mechanical Ventilation System "metal dud Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type Passive Heat Recover Ventilator (HRV) Capacity ` m cfins: Low: 117 lHigh: 1g9 Other, describe: Ens' Recover Ventilator (ERV) Ca c in cfins: Low: High: Location of dud or system: Continuous exhausting fan(s) rated capacity in elms: N/A Location of fan(s), describe: Cfin's Capacity continuous ventilation rate m cfins: " round dud OR FLEX Total ventilation (intermittent + continuous) rate in elms: "metal dud Created by BAM version 052009 Meridian Enwa Prodpets Load Short Form Job: Date: Mar 19, 2013 Entire House By: ENERTECH Project Information For: Capitani, Anne and Rick 4924 Whispering Way, Eagan, MN Design Information Htg Ctg~ Infiltration -15 88 Method Simplified Outside db (°F) Inside db (°F) 70 72 Construction quality Tight Design TD (°F) 85 16 Fireplaces 0 Daily range - M Inside humidity 40 50 Moisture difference (gr/lb) 43 38 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade MERIT 90 Trade ADP Model ML193UH090XP48C-` Cond 13ACX-036-230-13 AHRI ref 4792309 Coil L'19/3659++TD AHRI ref 3852006 Efficiency 93 AFUE Eff iciency 11.0 EER, 13 SEER Heating input 88000 MBtuh Sensible cooling 23940 Btuh Heating output 83000 Btuh Latent cooling 10260 Btuh Temperature rise 68 °F Total cooling 34200 Btuh Actual air flow 1140 cfm Actual air flow 1140 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.041 cfrNBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0:85 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Future Basement 959 13497 5635 268 231 Entry Level 1008 12834 5424 255 222 B-fast Nook 65 3049 2618 61 107 FP 6 550 115 11 5 Upper Level 1008 10191 5975 202 245 Over Garage 604 17268 8035 343 329 Entire House 3650 57390 27801 1140 1140 Other equip loads 8164 1275 Equip. @ 0.93 RSM 27012 Latent cooling 4979 TOTALS 3650 65554 31991 1140 1140 Bold/italic valuos have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 20 13-Mar-20 1 L.00:52 wrightsvft` Right-Suite® Universal 2012 12.0-13 RSUC2669 C: Users.Jell'Doa-unents Wrightson HVAC+Better Air, Captanl.rup Calc - MJ8 Front Door faces: Page 1 : Meridian Energy Job: Building g Analysis JoDate: Mar b 9, 2013 Entire House By: ENERTECH Project Information For: Capitani, Anne and Rick 4924 Whispering Way, Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Paul Intl Arp. MN, US Indoor temperature (°F) 70 72 Elevation; 837 It Design TD ( `F 85 16 Latitude: 45 ON Relative humidity 40 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 43.1 37.9 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 18 ( M) Method Simplified Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 6.8 24510 37.4 Glazing 25.5 9837 15.0 Doors 26.4 1109 1.7 r, Ceilings 1.9 3147 4.8 Floors 1.7 2890 4.4 Infiltration 1.7 6328 9.7 Ducts 9570 14.6 Piping 0 0 Humidification 0 0 Ventilation 8164 12.5 Adjustments 0 Total 65554 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 1.7 6095 21.0 n Glazing 38.3 14783 50.8 Doors 8.8 371 1.3 Ceilings 1.1 1926 6.6 Floors 0.1 163 0.6 Infiltration 0.2 637 2.2 Ducts 3827 13.2 - Ventilation 1275 4.4 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 29076, 100.0 k,Latent Cooling Load = 4979 Btuh Overall U-value = 0.067 Btuh/ft2- IF Data entries checked. Soldlitalia values have been manually overridden 1 Wr htsof - 2013-Mar-2014:00:52 flight-Suites Universal 2012 12.0.13 RSU02669 Page 1 C:'+Users%Jett\Doc urnentsMrightsoft HVACtBelter Air, Capitani.rup Calc a MJ8 Front Door faces; Mer&HanEneMNoducts Component Constructions Job: Date: Mar 19, 2013 Entire House By: ENERTECH Project Information For: Capitani, Anne and Rick 4924 Whispering Way, Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Paul Int'I Arp, MN, US Indoor temperature (°F) 70 72 Elevation: 837 ft Design TD (`F) 85 16 Latitude: 45 ON Relative humidity 40 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 43.1 37.9 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 18 { M) Method Simplified Wet bulb (`F) - 72 Construction quality Tight Wind speed (mph) 15.0 7,5 Fireplaces 0 Construction descriptions or Area U-Value Insul R Htg HTM Loss C19 HTM Gain It, Btuh)W-T it-°F,91uh 8104E Btuh BtuhV Btuh Wails 12E-Osw: Frm wall, stucco ext. 1/2" wood shth r-19 av ins, 1;2" n 297 0.068 19.0 5.78 1718 1.32 391 gypsum board int fns h, 2"x6" wood frm a 541 0.068 19.0 5.78 3128 1.32 712 $ 604 0.068 19.0 5.78 3491 1.32 795 w 559 0.068 19.0 5.78 3230 1.32 735 all 2001 0.068 19.0 5.78 11567 1.32 2633 wall, heavy dry or light damp soil,. 2"x4" wood int frm, concrete wall. n 342 0.090 .0 7.65 2616 2.49 850 r-1 cav ins, 8" thk: Bg wall, heavy dry or light damp soil, 2"x4" wood a 243 0.090 r9- 0 7-65 1859 2.49 604 t M. ccmrete wall.. r-10 cav ins. 8" thk a 80 0.099 9A 8.41 673 1.32 106 229 0.090 9.0 7.65 1752 2.49 569 s 96 0.099 9.0 8.41 808 1.32 127 w 262 0.090 9.0 7.65 2004 2.49 651 all 1252 0.090 9.0 7.76 9712 2.32 2907 12E-Osw: Frm wall, stucco ext, 1/2" wood shth r-19 av ins. 2"x6" s 5 0.068 1 . 5.78 29 1.32 7 wood frm w 17 0.068 19.0 5.78 98 1.32 22 all 22 0.068 19.0 5.78 127 1.32 29 Partitions 12E-Osw: Frm wall, stucco ext r-19 av ins.. 518" gypsum board int 351 0.068 19.0 8.84 3103 1.50 525 fnsh. 2"x6" wood frin Windows 2 glazing, clr low-e outr, air gas, vnl frm mat, cir innr, 1/2" gap, 114" a 132 0.300 0 25.5 3356 34.6 4556 thk: 2 glazing, clr low-e outr, air gas, vnl frm mat, cir innr, 1/2" gap, s 10 0.300 0 25.5 255 19.6 196 1/4" thk; NFRC rated (SHGC=0.32) w 190 0.300 0 255 4849 34.6 6583 w 54 0.300 0 25.5 1377 34.6 1869 all 386 0.30 0 25.5 9837 34.2 13205 Doors Door. mtl pur core type: Door, mtl pur core type n 20 0.300 10.5 25.5 506 8.53 169 e 22 0.320 10.5 27.2 603 9.10 202 all 42 0.320 10.5 26.4 1109 8.84 371 r - ri htsoft° 2013-Mar-20 14;00.52 w 9 Right-Suifee Universal 2012 12 0,13 RSU02669 Page 1 t C:`-users `.Jeff,.Documents\Wrightsott HVAC1Better Air, Capitan;.rup Calc . MJ8 Front Door faces: Ceilings" 16A-44ad: Attic ceiling, asphalt shingles roof mat, -44 I ins, 518" 6 0.022 44.0 1,87 11 1.58 9 gypsum board int fnsh 1677 0.022 44.0 1.87 3136 1.14 1917 all 1683 0.022 44.0 1.87 3147 1.14 1926 Floors 21A-28t: Bg floor, heavy dry or light damp soil 6.5' depth 107 0.022 0 1.87 2018 0 0 Fir floor, frm fir, 12" thkns, carpet fir fnsh r-43 v ins, tight: Fir floor, 604 0.049 43.0 1.44 872 0.27 163 frm fir. 12" thkns. carpet fir fnsh.. r-43 av ght YO & t's ? 13 ~I L htsoft` 2013-Mar-20 14:e 2 WC ~ ~ Right SiuteNl Universal 2012 12.0.13 RSU02669 Page 2 C. Users JeWDo"mer.wWrightsoft HVACtBetter Air, Capitani.rup Calc a MJB Front Door faces, Meriden Energy Products Job: Project Summary Date: Mar 19, 2013 Entire House By: ENERTECH Project Information For: Ca 'tani, Anne and Rick 4924 Whispering Way, Eagan, MN Notes: i- • Information Weather: Minneapolis-St Paul Intl Arp, MN, US Winter Design Conditions Summer Design Conditions / v Outside db -15 IF ✓ Outside db 88 OF Inside db 70 IF Inside db 72 °F Design TD 85 IF Design TD 16 OF Daily range M Relative humidity 50 % Moisture difference 38 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 47820 Btuh Structure 23975 Btuh Ducts 9570 Btuh Ducts 3827 Btuh Central vent (180 cfm) 8164 Btuh Central vent (150 cfm) 1275 Btuh Humidification 0 Btuh Blower 0 Btuh Piping Btuh Equipment load 5554 Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 27012 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 939 Btuh Ducts 284 Btuh Heating Cooling Central vent (150 cfm) 3756 Btuh Area (ft) 3650 3650 Equipment latent load 4979 Btuh Volume (ft') 32198 32198 Air changes hour 0.13 0.07 Equipment total load 31 to Equiv. AVF (cfm) 70 38 Req. total capacity at 0.70 SHR iPon Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade MERIT 90 Trade ADP Model ML193UH090XP48C-" Cond 13ACX-036-230-13 AHRI ref 4792309 Coil L'19/36S9++TD AHRI ref 3852006 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating input 88000 MBtuh Sensible cooling 23940 Btuh Heating output 83000 Btuh Latent cooling 10260 Btuh Temperature rise 68 OF Total cooling 34200 Btuh Actual air flow 1140 cfm Actual air flow 1140 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 13old!itatic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-20 1400:52 Wrightsoft' Rig11-Sui1e8 Universal 2012 12.0 13 RSU02669 Page 7 ' ~ Cr Users' Jeff'. Doc urrents'Wrlghtsoft HVAC%Better Air. Capitani.rup Calc m MJ8 Front Door faces: Products Ri ht-A Worksheet Job: g Date: Nor 19, 2013 Entire House By: ENERTECH 1 Room name Entire House Future Basernent 2 Exposed wall 411.0 It 128.0 ft 3 Room height 8.8 ft 9.0 ft 1.0 x 959.0 tt cod 4 Room dimensions 3650.0 W 959.0 ft2 5 Room area Ty Construction U-value Or HTM Area (W) Load Area (ftq Load number (Btuh11t2-`F) (Btuh+ft21 or perimeter (H) (Btuh) or perimeter (ft) (Bt h) Heat cod Gross NiP/S Heat Cool Gross N/P/S Heat cool 6 tq/ 12E-Osw 0.068 n 5.78 1.32 317 297 1718 391 0 0 0 0 l--D Door. mtl pur core t 0.3D0 n 25:50 8.54 20 20 506 169 0 0 0 0 W Bg wall, heavy dry o 0.106 n 7.65 2.49 342 342 2616 850 342 342 2616 850 12E-0sw 0.068 a 5.78 132 695 541 3126 712 0 0 0 0 1 1 -G 2 glazing, clr low-e 0.300 a 25.50 34.62 132 0 3356 4556 0 0 0 0 L--D Door, mil pur care t 0.320 a 27.20 9.10 22 22 603 202 0 0 0 0 W Bq wall. heavy drv o 0.106 a 7.65 2.49 243 243 1859 604 243 243 1859 604 W Bg wall, heavy dry o 0.099 . e 8.41 1.32 80 8U 673 106 - "0 0 0 0 VU 12E-Osw 0.068 s 5.78 1.32 614 604 3491 795 0 0 0 0 L---1" 2 glazing, clr low-e 0.300 , s 25.50 19.65 10 0 255 196 0 0 0 0 W 12E-Osw 0.068 s 5.78 1.32 5 5 29 7 5 5' 29 7 W Bo wall. heavv dry o 0.106 s 7.65 2.49 229 229 1752 569 229 229 1752 569 W Bg wall, heavy dry o 0.099 s 8.41 1.32 96 96 809 127 0 0 0 0 y1 12E-Osw 0.068 w 5.78 1.32 749 559 3230 735 0 0 0 0 L " 2 glazing. Or low-e 0.300 . w 25.50 34.62 190 0 4849 6583 0 0 0 0 W 12E-Osw 0:068 w 5.78 1.32 17 17 98 22 17 17 98 22 y! Bg wall, heavy dry o 0.106 w 7.65 2.49 316 262 2004 651 316 262 2004 651 I-G 2 glazing. cir low-e 0.300 w 25.50 34.62 54 0 1377 1869 54 0 1377 1869 P 12E-Osw 0.068 8.84 1.50 351 351 3103 525 0 0 0 0 C 16A-44ad 0.D22 1.87 1.58 6 6 11 9 0 0 0 0 C 166-44ad 0.022 1.87 1.14 1677 1677 3136 1917 0 0 0 0 F 21A-281 0.022 1.87 0.00 1079 1079 2018 0 959 959 1793 0 F Flr floor, frm flr, 0.049 1.44 0.27 604 604 872 163 0 0 0 0 6 " AED excursion 1578 864 Envelope loss'gain 41492 23337 11529 5437 12 a; Infiltration 6328 637 1969 198 b) Roan ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliancesrother 0 0 Subtotal (lines 5 to 13) 47820 23975 13497 5635 Less external load 0 0 0 0 Less transfer 0 0 0 D Redlstriboion 0 0 0 0 14 Subtotal 47820 23975 13497 5635 15 Duct loads 201/6 160/ 9570 3827 -0^/, DI/ 0 0 Total room load 57390 27801 13497 5635 Air required (elm) 1140 11401 1 268 231 Calculations oved b ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-20 -2014:age I Right Suited Universal 2012 12.0.13 RSU02669 Page C Users Jeff', Documents Wrightsoft HVAC':Better Air. Capitam.rup Caic = MJ8 Front Door faces riE °r«af Right-A Worksheet ai J: lea 19, 2013 Entire House By: .ENERTECH 1 Room name Entry Level B-fast Nock 2 Exposed wall 80.0 It 23.0 If 3 Room height 10.0 It heat/cod 9.0 It heaNcod 4 Room dimensions 1.0 x 1008.0 It 13.0 x 5.0 It 5 Room area 1008.0 Rx 65.0 ft2 Ty Construction U-value Or HTM Area (ft") Load Area (ft2) Load number (BtutVft2-'F) (Btuhift2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cod Gross WPiS Heat Cool Gross NIPS Heat cod 6 12E •Osw 0.068 n 5.78 1.32 0 0 0 0 45 25 145 33 t---D Doo, mtl pur core t 0.300 n 25.50 8.54 0 0 0 0 20 20 506 169 W Bg wall. heavy dry 0 0106 n 7.65 2.49 0 0 0 0 0 0 0 0 12E-Osw 0.068 a 5.78 1.32 270 213 1230 280 0 0 0 0 11 2 glazing, cir low-e 0.300 a 25.50 34.62 35 0 893 1212 0 0 0 0 L - O Door, mtl put core t 0.320 a 27.20 9.10 22 22 603 202 0 0 0 0 W Ba wall, heavv drv o 0.106 a 7.65 2.49 0 0 0 0 0 0 0 0 W Bg wall, heavy dry o 0.099 a 8.41 1.32 80 80 673 106 0 0 0 V~r 12E-Osw 0.068 s 5 76 1.32 243 243 1405 320 45 35 202 46 t--G 2 glazing, dr low-e 0.300 s 25.50 19.65 0 0 0 0 10 0 255 196 W 12E-Osw 0.068 s 5.78 1.32 0 0 0 0 0 0 0 W Ba wall. Heavy drv o 0.106 s 7,65 2.49 0 0 0 0 0 0 0 0 W Bg wag, heavy dry o 0.099 s 8-41 1.32 96 96 808 127 0 0 0 0 y1 12E-Osw 0.068 w 5.78 1.32 207 148 854 194 117 77 445 101 L---G 2 glazing, clr low-e QM0 w 25.50 34.62 59 0 1511 2051 40 0 1020 1385 W 12E-Osw 0.068 w 5.78 1.32 0 0 0 0 0 0 0 0 ~J Bg wall, heavy dry o 0106 w 7.65 2.49 0 0 0 0 0 0 0 0 t-11- 2 glazing, clr low-e 0.300 w 25.50 34.62 0 0 0 0 0 0 0 0 P 12E-Osw 0.068 8.84 1;50 351 351 3103 525 0 0 0 0 C 16A-44ad 0.022 1.87 1.58 0 0 0 0 0 0 0 0 C 168.44ad 0.022 1.87 1.14 0 0 0 0 65 65 122 74 F 21A-28t 0.022 1.87 0.00 120 120 224 0' 0 0 0 0 F Flr floor, frm ffr. 0.049 144 027 0 0 0 0 0 0 0 0 1 6 c; AED excursion 253 577 Envelope lossigain 11303 5270 2695 2582 12 a) Infiltration 1531 154 354 36 bi Roan ventilation 0 0 0 0 13 Intemaf gains Occupants @ 230 0 0 0 0 Appliancesiother 0 0 Subtotal clines 6 to 13) 12834 5424 3049 2618 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12834 5424 3049 2618 15 Duct loads -00i 0°% 0 0 -01% 0% 0 0 L Total room load 12834 5424 3049 2618 Air required (cfm) 255 222 61 107 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsc2 t- 2013-Mar-2014:00:52 Right-Suited Universal 2012 12.0.13 RSUD2669 Page 2 ACZ& C:`,Users'1Jeff+Docurrents',Wrtghtsoft HVACiBelter Air, Capilani,rup Calc MJ8 Front Door faces: MaWlen , Pi Right-A Worksheet Job: Date: Mar 19, 2013 Entire House By; ENERTECM 1 Room name FP Upper Level 2 Exposed wall 8.0 if 102.0 it 3 Room height 9.0 it heat1cool 8.0 it heat/cool 4 Room dimensions z 1,0 x 6.0 it 100B.0 . ft 1.0 x 1008.0 it 5 Room area 6.0 it z Ty Construction U-value Or HTM Area (it') Load Area (ttz) Load number (BtufViI2_0F) (Btuh412) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N,P,`S Heat cool 6 Wd 12E,Osw 0.068 n 5.78 1.32 0 0 0 0 24 24 139 32 l-D Door, mtl pur core t 0.300 n 25.50 8:54 0 0 0 0 0 0 0 W Bg wail. heavy dry o 0.106 n 7.65 2.49 0 0 0 0 0 0 0 0 Val 12E-0sw 0.068 a 5.78 1.32 9 9 52 1 240 178 1027 234 1 1 E-- G 2 glazing, cir lower 0.300 is 25.50 34.62 0 0 0 62 0 1591 2160 L---D Door, mtl pur core 1 0.320 a 27.20 9.10 0 0 0 0 0 0 0 0 W Ba wall, heavv drv o 0.106 a 7.65 2,49 0 0 0 0 0 0 0 0 W Bg wall, heavy cry o 0,099 a 8141 1-32 0 0 0 0 0 0 0 0 U~+ 12E-Osw 0.068 s 5.78 1.32 54 54 312 71 264 264 1526 347 t--G 2 glazing, clr low-e 0.300 s 25.50 19.65 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 5.78 1.32 0 0 0 0 0 0 0 0 W Bo wall. heavy dry o 0.106 s 7.65 2.49 0 0 0 0 0 0 0 0 W Bg wall, heavy dry o 0:099 s 8.41 1.32 0 0 0 0 0 0 0 0 12E-Osw 0-068 w 5.78 1.32 9 9 52 12 288 239 1382 315 2 glazing, cir low-e 0 300 w 25.50 34-62 0 0 0 0 49 0 1247 1693 W 12E-Osw 0.068 w 5.78 1.32 0 0 0 0 0 0 0 0 ~l Bg wait, heavy dry c 0.106 w 7.65 2.49 0 0 0 0 0 0 0 0 L--G 2 glazing. cir low-e 0.300 w 25.50 34.62 0 0 0 0 0 0 0 0 P 12E-0sw OMB 8.84 1:50 0 0 0 0 0 0 0 0 C 16A-44ad OM2 1.87 1.58 6 6 11 9 0 0 0 0 C 16B-44ad 0.022 1.87 114 0 0 0 0 1008 1008 1885 1152 F 21 A 28t 0.022 1.87 0.00 0 0 0 0 0 0 0 0 I I F Fir flow frm flr, 0.049 1.44 0.27 0 0 0 0 0 0 0 0 C 6 c) AED excursion -2 -98 Envelope lossigain 427 102 8796 5834 12 a) infiltration 123 12 1394 140 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances, other 0 0 Subtotal (lines 6 to 13y 550 115 10191 5975 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 550 115 10191 5975 15 Duct loads -0"/ NO 0 0 -0% 01/ 0 0 Total room load 550 115 10191 5975 Air required icfm) 11 5 202 245 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightso t' 2013-Mar-20 14:00:52 Right-SuifeS Universal 2012 12.0.13 RSU02669 Page 3 C:' Users,JeffiDocuments,Wrightsoft HVAC'xBetter Air, Capitani.rup Calc = MJ8 Front Door faces: M Ri ht-A Worksheet Job: 9 Entire House Date: Mar 19, 2019 By: ENERTECH 1 Room name Over Garage 2 Exposed wall 70.0 it 3 Room height 8.0 It heal/cool 4 Room dimensions 1.0 x 604.0 ft 5 Room area 604.0 it' Ty Construction U-value Or HTM Area (W) Load Area Load number (Btuh"ft"-°F) (Btu 12) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N,PIS Heat Cool Gross N/P-`S Heat cool 6 y~r 12E-Osw 0.068 n 5.78 1.32 248 248 1433 326 Door, mtl pur core t 0.300 n 25.50 8.54 0 0 0 0 W Bg wall. heavy dry o 0.106 n 7.65 2.49 0 0 0 0 T 12E-Osw 0.088 a 5.78 1.32 176 142 820 187 i t 1- 2 glazing, clr low-e 0.300 a 25.50 34.62 34 0 872 1184 --D Door, mtl pur core t 0.320 a 27.20 9.10 0 0 0 0 W Bo wall, heavy drv o 0.106 a 7.65 2.49 0 0 0 0 W Bg wall, heavy dry o 0.099 e, 8.41 1.32 0 0 0 0 V~ 12E-0sw 0.068 s 5.78 1.32 8 8 46 11 I---( 2 glazing, clr low-e 0.300 s 25.50 19.65 0 0 0 0 W 12E-Osw 0.068 s 5.78 1.32 0 0 0- 0 W BQ wall, heavy drv o 0.106 s 7.65 2.49 0 0 0 0 W Bg wall, heavy dry o 0.099 s 8.41 1.32 0 0 0 0 12E-Osw w 0.068 w 5.78 1,32 128 86 497 113 2 glazing, clr low-e 0.300 w 25.50 34.62 42 0 1071 1454 W 12E-0sw 0,068 w 5.78 112 0 0 0 0 yI Bg wall, heavy dry o 0.106 w 7.65 2.49 0 0 0 0 t-G 2 glazing, cir low-e 0.300 w 25.50 34.62 0 0 0 0 P 12E-Osw 0.068 8.64 1.50 0 0 0 0 C 16A-44ad 0.022 1.87 1.58 0 0 0 0 C 16B-44ad 0.022 1.87 1.14 604 604 1129 690 F 21A-28t 0.022 1.87 0.00 0 0 0 0 F Fir floor. irm fir, 0.049 1:44 0.27 604 604 872 163 f I 6 ci AED excursion -16 Envelope lossrgain 6741 4112 12 a) Infiltration 957 96 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliancesiother 0 Subtotal dines 6 to 13) 7698 4208 Less external load 0 0 Less transfer 0 0 Redistritxition 0 0 14 Subtotal 7698 4208 15 Duct toads 124% 91% 9570 3827 Total room load 17268 8035 Air required icfm) 343 329 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Pk vvr1ght:sof[- 2013-Mar-20 14:00:52 Right-Suile® Universal 2012 12.0.13 RSU02669 Page 4 ' C `,Users.Jelf:DocumentsjWrighisolt HVAC?Better Air, Capitani.rup Cale - MJ6 Front Door faces: Directions - In order to determine the makeup air for ventilation. Table 501.4. must be filled out (see below). For most new installations. column A will be appropriate, however, if kitchen hoods exceed 300 cfm. atmospherically vented appli- ances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is nega- tive, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional makeup air will be required for combustion appliances, see KAIR method for calculations) - One or multiple power One or multiple fan- One atmospherically multiple atmospheri- vent or direct vent assisted appliances vent gas or oil appli- tally vented gas or oil appliances or no com- and power vent or ance or one solid fuel appliances or solid bustion appliances direct vent appliances appliance fuel appliances Column D Column A Column 8 Column C 1 0.15 I 0.09 0.06 0.03 a) pressure factor cfmtsf) -----b) conditioned floor area (sf) (includ--~-; in unfinished basements Estimated House Infiltration (cfm)' 80 1ax1b 2 Exhaust Capacity a) continuous exhaust-only ventita- i tion system (cfm), (not applicable to i balanced ventilation systems such as HRV) b) clothes dryer (cfm) 135 135 135 135 c) 80% of largest exhaust rating (cfm), '4r' (not applicable if recirculating sys- tem or if powered makeup air is electrically interlocked and match to exhaust) ` d) 80% of next largest exhaust rat- 1 ing (cfm): (not applicable if recirculating sys- tem or if powered makeup air is electrically interlocked and matched to exhaust Total Exhaust Capacity (cfm); 2a + 2b +2c + 2d 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) 10011, - e r b) estimated house infiltration (from above Makeup Air Quantity (cfm), _ 13a - 3bj (if value is negative, no makeup air is needed ` 4. For makeup Air Opening Sizing, Not regWrod, t gittve refer to Table 501.4.2 nullitier A. Use this column if there are dtherthaRfan=5ssi t dhor atmospherically vented gas or oil appliance or if there are no combustion applianc- es. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel ap- pliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Page 3 of 6 Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction, 4b of step 4 is required to be filled out. The example assumes a typical 3.000 square foot home with a finished basement that has a mechanical room that is 10 feet wide by 12 feet long with an 8 foot ceiling. It also assumes installation of a 70.000 btu. 2 pipe condensing furnace: and a 40, 000 Btu. power vented water heater. IFGC Appendix E. Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace Boiler. and%or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace. /Boiler Draft Hood Fan Assisted 2L Direct Vent Input: _70M Btu/hr (_not fan-assisted & Power Vent Water Heater _ Draft Hood X Fan Assisted _ Direct Vent Input 40.000 Btu/hr (not fan-assisted & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. Y The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 960 ft _ LxHXW=8x10x12=960cubicfeet Step 3: Determine A.r Changes per Hour (ACH)l Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (00 NOT COUNT Input Btu/hr DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required TRV, ft- Volume (TRV) If CAS Volume !from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5, 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan-assisted and power vent appliances Input: 40.000 Btu/hr (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3.QW ft' Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non-fan-assisted appliances Input: 0 _ Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find RVNFA' norte ft' Required Volume Non-Fan-Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA TRV = 3MM + none = ft' If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed If CAS Volume from Ste 2) is less than TRV then o to STEP 5. Step 6: Calculate the ratio of available interior volume to the total required volume Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) 3.t1 4Q 32 Ratio = 1 Step 6: Calculate Reduction Factor (RF) = 1 - _ RF = 1 minus Ratio Ratio RIF Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: 41000 Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided b 3000 Btu/hr per in` CAOA = 13000 Btu/hr er inz = in' Step 8: Calculate Minimum CAOA Minimum CAOA = CAOA multi lied b RF Minimum CAOA = x = in' Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 113 ~ Minimum CAOA = in Aid OD = 1. 13 X sqiMre root tsf a07 a A to r;retct' orA 0*404 R_ 1 If desired ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304 Page 5 of 6 Building Code Division r'Of 208 NW 1st Ave Faribault MN 55021 Fax: (507) 384-0507 r bault Alan Ernste, Building Official (507) 333-0347 Dave Mathews, Building Inspector (507) 333-0357 www.ci.faribault.mn.us Schedule Inspections (507) 333-0387 Ventilation, Makeup and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction. Site address ~l/ 1 Q ru 4v~ K) Date HVAC Completed Contractor B Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including Basement -finished or unfinished) Total required ventilation Number of bedrooms Continuous ventilation Section B Ventilation Method _ Choose either balanced or exhaust only) 3Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - efm of unit in low must not exceed con- Continuous fan rating cfm tinuous ventilation rating b more than 100%. Low cfm High 1 f " Continuous fan rating in efrn (capacity must not exceed d continuous ventilation rating b more than 100% Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation Section D Controls Describe operation and control of the continuous ventilation) Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4,1) Powered (determined from calculations from Table 501.4.1) P# f.,. Interlocked with exhaust device (determined from calculation from Table 501.4. 1) Other, describe: Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type Other. describe: Notes. Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: http://www ci, faribault.mn uVdepariments/buildingcode/program. N I S N d ~I 1 fi W y G O m °n ~ r w ® I N y : , r r ~ i O m c v ~ aS a m a m x •ro ~ o= r ~I v ~ ~I, W • N O G J U ~ x \ I ~ C 0 0 0 0 O t ~ ro '0 r0 R5 Q M M M M M I \ ~ _ _ H m p N H rt 9~ ~ ~ n d c~ n. ~ N n n r tr ~ e I ~ - rt Y, Y 61 N \r Y ~ r Y !7 \ N a N tp r~ \ I 'ST Y Y O 9 O N 4 N IAII Q II A~ i }5 O ~ I 2 V N A N j N i I N i ~ cc @ N rt ID n ~ n S1 _ N N fl j ro H F'• N• It i { i H o d mm7 ~ ~ 'i ~ ~ ~ 1 ~ 1 l t> i`- G r, n n n z m r firer ro w m :~n H ,7 ~ ~ ~ v C v C x m m ~ i i ~ iF Li i m m o 0 0 0 0 0 0 0 0N o a 0 o O d j1~~ I! 49 N 47 N N p M M M M M Q, I NTI FN DS 0 0 0 0 0 Ul n -1 rt r ° a vm ~ 7 N n r, N rn b w A W N m N ro n r a N I .D r r n o m m 0 n 7 ~ O II H F' I O I". H i+ N w N ii 0 0 N J O O N o i r 0 m w N N i I N o'" zn zo~ a Qr r o ~ _ A RIZA omo iEq W S 1o bo sh cc eS~Nz q O m a W r i 'o N crm~ o l° Pmv cOc mon 9 1f 9a ymrm yzz .1 r V a ~ m~ i W y 3' N i Q„ 30'6°_ TO", 3'0" _ 5' 11 1/4' 30'6" 5' 1.1-1/4" 5'.4"-. I C STR11C'FURAL FASCIA L'J l " y rO tAC OF OEADFR ~roz _ - --N C 02 4 N W _ 02 a > a 'a 7 rHr^ GB \ cJl a Fi UI I~ GI r z ro I~).,J2 G6 1.~ J! j 11 N ~Y] - O 1.4 . I V~ lA C6 ~ 71 11 I H 1!FFF✓✓V~~++, O 7f It b _ 4 ro Ice it H G6 II 11 ~•1 •-Tr 11 i c GS 4 - it H C v I _ G2 U JI Y _ C G4 7 cil 4a - I - L 1 rII C I XG it 4 ~ ~ I} II 1 ~ ,J w G4 CJ1 m m _ _ Gl _ r C a 5 ti G2 02 G3 ~ (51 IMUS2$ IiGR - _ y _ i Gs - H C7 tl m 0 U) C: E - ;u (1) G E a e a a x m - =R,I - - - - - W ¢ D 97 G2 E w _ \ M N U d ! ' cz FI UI N W N o o to N •1'1JU26H - 11 i-+ G2 r F1 o O o 0 0 0 4 w _ - y r ro ro ro ro ro _ G2 M m m m m m _ j G2 - ----niJU26 R. 1.. x cill H N n h k rt # O' I- \ F`- M nl 0 t # W fu W tsl G w m m ro r \ N w 5' w rt 5 _ ro - - - - - - - ~ n M N m to ~ i N \ _ N lQ N I 17 \ i I' w O II W 1 N N ` w N N in m 2' 0".7' 6" - 30'_01. 0 C) m ~ r, N A ~ A i a r a 3 ~ ~ H toy ~ m m~r~ f LQ 10 _ H Y• sr - . tt r n v - 3 IS u. ; t I ` i t i I i. I t~ i J n n n n z m r i ~1 ~I r b H b~ ~ q ;n ~,I t Il (D 0, M m m I V6' to N c _ N ~ ~ 0 J m VI VI O O O [j' \ rt I o o o o o o I~ f LR rR `S _S 1t 2„ 1 C o o o o o\ N b fff N N v(1 0 N ~ i M M M M M p, - PAINTED ENDS - x b O b b b to £ m m ~ h h 0 Y u n 7 N n n N v M ro ~ i w a ~ o tr \ N a ro n H a N\ J N w rt n o m a o n p \ w \ o I H O r"o p N N W N n o o N O O 0 I 0 ~ W N N f r 1 N g ~ S off! g y = cl W I t zrokz I j~ , , ! r- , r r ! a dlad o m v . am.; nmr i,? ~ fir- e !N noon z m; i _ _ _ „ L am o.m xma I -r~ ~ m O C O O P p O O G O O I - - !J I M M M M M I tJ ~ 1 1 _ i ~ ~ I T L5 N. ' 7 of N ~ f ' w n " , ,C N 11i In d VT GG . . , ..M ' O IA i ✓P I b ; s~ I WHISPERING WAY CERTIFICATE OF SURVEY For Vennehjem Building Corp. Lot 10, Block 1, WHISPERING WOODS ELEVENTH ADDITION Tree Preservation plan Pre House Proposed Post House Development Construction Tree Preservation Constructio Const. As-Built Post House Const. As-Built 0 > z O > z LIJ j F_ O P- w w F__ O F__ w (n z > V) U) z 57< 0 POINT NO. ELEV. TYPE DIA U ~ w U) U (If w 1 10 981.9 AK 22 X X 1 1 984.9 CHERRY 10 X X 1514 986.4 9 X X 151 98 OA 14 X X 1516 986.6 OAK 14 X X OFFSITE ES 13 981. A 14 X 1509 9 .7 POPLAR 7 X Preliminary Tree Certification During a site visit on March 26, 2013 all significant trees shown and designated hereon were present and in good health, except as noted in the table above. x 0 The house has been staked. Tree fence will need to be placed outside the dripline of all significant trees to be saved. Future grading and construction should not have a negative effect on these trees. 0 By. Date: By. Date: o Harold C. Peterson, Minnesota L.S. No. 12294 Signature of Owner o .1 Scale: 1"=30 ' Page 3 of 3 James R. Hill, Inc. r , gZt4 WHISPERING WAY CERTIFICATE OF SURVEY For. Vennehjem Building Corp. PROPERTY DESCRIPTION: Lot 10, Block 1, WHISPERING WOODS ELEVENTH ADDITION, Dakota County, Minnesota. We hereby certify that this is a true and correct survey of the above described property and that it was performed by me or under my direct supervision and that I am a duly licensed Surveyor under the laws of the State of Minnesota. That this survey does not purport to show all improvements, easements or encroachments, to the property except as shown thereon. Signed this 26th day of March , 2013. James R. Hill, Inc., R WED f Date By. RAGAN ENGU4EERING DEPT, Harold C. Peterson, Minnesota L.S. No. 12294 Notes: 1. Building dimensions shown are for horizontal & vertical placement of structure 0 Denotes set spike only. See architectural plans for building o Denotes set iron monument • Denotes found iron monument & foundation dimensions. x927.6 Denotes existing elevation 2. No specific soils investigation has been (930.0) Denotes proposed elevation completed on this lot by James R. Hill, Inc. Denotes proposed drainage Y tc Denotes top of curb The suitability of soils to support the specific house proposed is not the responsibility of Bench Mark: 984.99 _TNH-LOTS 6 & 7, BLOCK 1 James R. Hill, Inc. or the surveyor. Proposed Garage Floor 0 Front= 987.8 3. No specific title search for existence or non- Proposed Garage Top of Block= 988.2 existence of recorded or un-recorded easements Proposed House Top of Block= 988.2 has been conducted by the surveyor as a part Proposed Lowest Floor= 980.5 of this survey. Only easements per the recorded plat are shown. 4. Proposed grades shown were taken from Bearings are on assumed datum the grading &/or development plan prepared by Scale 1A=30' N/A James R. Hill Inc. m v ° °o D < N NJ o D PLANNERS / ENGINEERS / SURVEYORS Om D~g N 2500 W. Cn Ra 42, WX 120, MN 55337 lic v o o m F CD Z v m PHONE: (952)890-6044 FAX: (9526244 1943 94-M UIE NE, Su1E B, &mC MN 55449 PHONE: (763)792-1136 FAX (763)792-1743 i WHISPERING WAY CERTIFICATE OF SURVEY For Vennehjem Building Corp. Lot 10, Block 1, WHISPERING WOODS ELEVENTH ADDITION Tree Preservation plan Pre House Proposed Post House Development Construction Tree Preservation Construction Const. As-Built Post House Const. As-Built o > z o > z Lij > 1 O ~ w w 1- O V) :2 U) z > V) :2 c i z POINT NO. ELEV. TYPE DIA Ln 0 ~ w o U) 0 ~ w o 1510 981.9 AK 2 X X ER 2 1 1 984.9 H Y 10 X 1514 986.4 MERRTTDU_ 9 X X 151 AK 14 X 1516 986.6 OAK 14 X X OFFSITE EES 13 981.0 OAK 1 14 1509 9 .7 P PLA 7 Preliminary Tree Certification During a site visit on March 26, 2013 all significant trees shown and designated hereon were present and in good health, except as noted in the table above. x 0 The house has been staked. Tree fence will need to be placed outside the dripline of all significant trees to be saved. Future grading and construction should not have a negative effect on these trees. 0 By. Date: By. Date: o Harold C. Peterson, Minnesota L.S. No. 12294 Signature of Owner o Scale: 1"=30' Page 3 of 3 James R. Hill, Inc. c a~ N t > ca Uw f W SD L LU m o o o w L c ~ me v $D Z m U Um cc p c 00000001 o r m 2 L QQJQ N E > 0 = O N J H H~ '0 1 E= a '3 m 0 c o VZ m 0 ZO Si ErQ) o w 8 'c- p voi ° Q m C cc vi ° O CU ~ e = v 0 Qa m 1`-m 0 ~w ° (DVvItcm VN ~t o N v m W Sl U) c° H Q _ a 'a m a~ 0 O s m'°- o c a F- g a F- c o N W C) L- L 4) 0 .2 t > o .0 V) cc 0 ~~in 3 E c Q = m IN " E. i- r o a a~ > Z o YV Q~ o n LE 00) E c 0000000 0 co ° u ° U E E J 0 Co BaCCc mu) C U)i O 0 0 E N 9 'a 3 O tl `5 O F- ~ 1- I- Z 1- r2 c~ N O N p Q L- N 11 O a o N 0 0 m J > N Z W L O •3 CD O 0 .0 S = 0 O O 0 _ O m O cc 3 CL c iQ- ~.EN -°°No E O 11 aj cn ''O~'!' p N t E 'a r 'a 0 C%j CM a) > II a ?J 0R O 'a 0 N N _N CD V U> 0 a N _ E N j a> O 0 ..i O di O E 0 O O per Z O F- Z O , O H 0 d V= V Z 4) O$ N to 4) 0 a `r c °m m 0 n 0) 3~ E a a o W~ a) cc 0 o Q~ maaLC)a~~ N ao a t9 - °as a~ E 0 U W CL 0 in 7i m x~I a caa Q. oo-aoo 06 0a~a 0 F- co CO)0Xco0 ZHIxww ir) C) 69 c a) cc Co U w ° w m f- cu o m m ?T a' a) E ° w o cm a) cu O a m m U m c c z ° O c o000000! o a) o _ ca L 4 a) ca J a) ~ aaiv E > D a) EED ~a) U F°- m E ~ C O J `t o Z a ® a) U Z 2-1 O O v ZO ~(n a) o Q 0 ai`~ a) P O L w L 02 Q m h ~°0 >w v U) ~ cu Q a) 0) w~ L 7 P w a) _ O a ® ~ w a cu O .0 U) ~ cu O H t ca O O O IN 'r"- E '0 L O r U N O F- r ° Z 0 E Urn o 0000000 o c m= a) E 0 a) O~ La) ° 9° a)v E -j a) ce »r Ac -a -,i5 m a3 M (n' L v L m(n a a` )i a) a) 2-0 3' O' L ° CD a) 70 a) w ° a) C a) ° L L L L L E- a a) Z F- 0 o O Q L 11 O u C3 Q ° 0 a) o° P N L a) C3) w u) J o > o Z cu a) o a) o cu E O N ° N 0 ° M N O Oa cu 3 = O r- O a _ a) L } s- O U a U) Q Q' J O ^ _ ~ Z F- O O~ C N 0 M L eF a to c - a) E O 11 U - a N N W a) O II O O _J cu NsttV N_P ' - C OV ; 0 N V a) = n to N" to O N O S= a) a) 0 U) 0 a) Z 0° ° F- a N N O z w L) F® ° c C 'D 04 - cm UJ E H e a) a°) nCD F a) c ° cc a CD CL 0) cu w CD cm a) a -0 4? 10 2 LI] o cu a) w CL CD CO - -F 'E ° X L _ 0 ° ° N WHISPERING WAY CERTIFICATE OF SURVEY m BuilUding Corp For: Venneh'e U EX15~NG C) HpUSE o J I j C ] / g84.3 C ] co c~ %130.05 7°0420" 00 rn --32-61-- - 36.59 - 'Z004 369 C \ C 13.46- to 0 ° 98.8 _ -p ° 979.1 an 975. I _ A-14001'30" - \ 10 x 10.31 19.17 25 985.0 ssXso6 / xsso.s II R=55.00 i 018. 83 33a o r ri 0) O S• M r r L~J 3 \O co 979.2 974.71 < 01) 0) W F- o / / p\0 0 r ' I z 11 N 0 Q \ A - I z Q 985.9 •0 pg o 7 ~5 p of O I k OV J h J \ 1 x 980.4 - II - ~ Of Li of tW -4- V) - Z ~ o~ / 98`x~ 514 F- LLJ 1Q?i ~p ~ _ s' / On rot / O 0 z D ►o 0, LL1 N~ ~/~T~ ~c 981.9 Q - 11 C Li. u 2 I 0) 1510 Q N ( I 0 W - J W (98fie6j o Q ` W W t ,n 9cn6. -1513 0 w ` 25 t l~' IL 11 / ~Y w x 984.9 ` 15161/_ LU ao ELEC. 'n 978.8 `n 74._ ~ ---31.40-- - 37.16 - - ~ _ l'-- 159.78 S89°47'1 0"W 974 o r o - (V 15.0 10.0N I nT - 0 p L_~J t 1 1 w = CJ c' _J N PROPOSED HOUSE' 1,855 SQ.FT. 'i OR 13.0% OF LOT AREA ° .DRIVEWAY = 600 SQ. FT. o SAN. SERVICE INVERT LOT 10 = 14,286 SQ. FT. ELEV.= TO BE FIELD DETERMINED BY CLIENT Scale: 1"=30' Page 2 of 3 James R. Hill, Inc. _ City Inspection Dept. Copy City of E(ipn City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) I li Development WHISPERING WOODS 11th ADDITION Lot Number 10 Block Number 1 Address 4924 Whispering Way Builder Vennehiem Building Corp. Phone Number:-952-890-3000 Contact: Joe Hilla Tree Protection Requirements: X Tree Protection Fencing Installed on Site (Re-set fencing when it gets loose, throughout entire construction process). Oak Tree Pruning (Immediately seal wounds during April 22 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required FAGAN FORESTRY DIVISION As Follows: R Attachments: `EP. VIEWED N ED X Yes (Refer to att Pfd 2d~~:z N No DATE 7,~ f Additional Notes: H:\ghove\2012fi1e\treepres\Tree Preservation Plan Whispering Woods 11" Addition Lot 10 Block 1 I , N WHISPERING WAY CERTIFICATE OF SURVEY For: Venneh',em Building C W A~ 1 ^T u F- ,n ~4 c~ _ 9843 C~ r co 8. 0' 32.s,- 130.05 7°04'20"E <c - - 36.59 - = '365 13.46- 0 985.8 - --o 979.1 N 975. 17 I-- A-14°01'30" 10 965.0 16 8X.8 ' R=55.00 1883 33C I x980.9 1 25 = o noN 3, o J ~ 979. 974.71 I a a' W I-- 0 / / 0 ~.J II II w \ O o o r o -4 z \ O o, 985.9- ft g N ~Sp"~~ rn' Q 1~'I11 ~o O CJ V O~ x980.4 Fad` II Ll) Ca of k' (n rn / 985.8x / 1514 S S ? ui Q a ao Cl) ~o '1500 / O Lu z 1 I' LL- It, N~ W C 0) Ld ~ ICY) 1 o 1510 981.9 Q U ~i LLJ 0) J ` W cQ wOJW in [A ' 9 1 ~.r 0,513 0) 11 ' CL ` ` i i (~j~ 15V16 7984.9 25 EL . u? 978.8 974.8 Cl- T 31.40 - 37.16 - s09 - 159.78 S89047'1 0"W 974.9 n CIO 0 --25.0-- 003 _ 15.0 10.0 v F OTOC z L_~ I I I (D ✓ o - J - J • 2 PROPOSED HOUSE = 1,855 SQ.FT. OR 13.0% OF LOT AREA .DRIVEWAY = 600 SQ. FT. SAN. SERVICE INVERT ° LOT 10 = 14,286 SQ. FT. ELEV.= TO BE FIELD DETERMINED BY CLIENT Scale: I"=30' Page 2 of 3 James R. Hill, Inc. LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: J'A d /emu - DATE O SURV~Z6~3 LATEST REVISION: m c c~ t U a O z Q DOCUMENT STANDARDS ❑ ❑ . Registered Land Surveyor signature and company ❑ ❑ . Building Permit Applicant ,0- ❑ ❑ • Legal description ❑ ❑ ❑ . Address J;X ❑ ❑ . North arrow and scale ~[Y ❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.) ,ef° ❑ ❑ • Directional drainage arrows with slope/gradient % ❑ ❑ . Proposed/existing sewer and water services & invert elevation ,Pl ❑ ❑ . Street name ❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.) ❑ ❑ . Lot Square Footage ❑ ❑ . Lot Coverage ELEVATIONS Existing ❑ ❑ . Property corners ❑ ❑ Top of curb at the driveway and property line extensions ❑ ❑ . Elevations of any existing adjacent homes ❑ ❑ . Adequate footing depth of structures due to adjacent utility trenches ❑ ❑ . Waterways (pond, stream, etc.) Proposed ❑ ❑ • Garage floor ❑ ❑ . Basement floor ❑ ❑ . Lowest exposed elevation (walkout/window) ❑ ❑ . Property corners ❑ ❑ . Front and rear of home at the foundation PONDING AREA (if applicable) X ❑ ❑ . Easement line X ❑ ❑ . NWL jd ❑ ❑ . HWL ❑ ❑ • Pond # designation ❑ ❑ . Emergency Overflow Elevation ❑ ❑ . Pond/Wetland buffer delineation Y . Shoreland Zoning Overlay District t A-1 Y • Conservation Easements DIMENSIONS ❑ ❑ . Lot lines/Bearings & dimensions ❑ ❑ . Right-of-way and street width (to back of curb) ❑ ❑ • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ❑ ❑ Show all easements of record and any City utilities within those easements ,,?I' ❑ ❑ Setbacks of proposed structure an yard setback of adjacent existing structures ❑ ❑ Retaining wall requirements: Reviewed By: Date ~i G:/FORMS/Cert. of Survey Checklist Rev. 3-3-11 +724 WHISPERING WAY CERTIFICATE OF SURVEY For Vennehjem Building Corp. PROPERTY DESCRIPTION: Lot 10, Block 1, WHISPERING WOODS ELEVENTH ADDITION, Dakota County, Minnesota. We hereby certify that this is a true and correct survey of the above described property and that it was performed by me or under my direct supervision and that I am a duly Licensed Surveyor under the laws of the State of Minnesota. That this survey does not purport to show all improvements, easements or encroachments, to the property except as shown thereon. Signed this 26th day of March , 2013. James R. Hill, Inc., IEWED - DK BY F:AGAN kNGUN]EEkiNG DEPT. Harold C. Peterson, Minnesota L.S. No. 12294 Notes: 1. Building dimensions shown are for horizontal & vertical placement of structure A Denotes set spike only. See architectural plans for building o Denotes set iron monument • Denotes found iron monument & foundation dimensions. x927.6 Denotes existing elevation 2. No specific soils investigation has been (930.0) Denotes proposed elevation completed on this lot b James R. Hill, Inc. Denotes proposed drainage Y tc Denotes top of curb The suitability of soils to support the specific house proposed is not the responsibility of Bench Mark: 984.99 _TNH-LOTS 6 & 7. BLOCK 1 James R. Hill, Inc. or the surveyor. Proposed Garage Floor @ Front= 987.8 3. No specific title search for existence or non- Proposed Garage Top of Block= 988.2 existence of recorded or un-recorded easements Proposed House Top of Block= 988.2 has been conducted by the surveyor as a part Proposed Lowest Floor= 980.5 of this survey. Only easements per the recorded plat are shown. 4. Proposed grades shown were taken from Bearings are on assumed datum the grading &/or development plan prepared by Scale= 1'=30' N/A CD James R. Hill, Inc. > -0 CD m v ° ;0 PQ °o D < ~ o > PLANNERS / ENGINEERS / SURVEYORS O M ~I N D r- o N v_, a) r 2500 W. Cnr. RD. 42, Sm 120, Bum MN 55337 o J o o M v m ~ PHONE (952)890-6044 FAX: (952 90-6244 1943 941H LNE NE, SME B, BUM MN 55449 PHONE: (763)792-1136 FAX (763)792-1743 t A- Z. WHISPERING WAY N CERTIFICATE OF SURVEY For -Vennehjem Building Corp. 3:1 Maximum Slopes or Retaining Wall Wiv W Required ' ~,XISTING ' CJ ~ NpUSE ~ I F- 0,01 r1-r VIA ~4 C~ r. r~.►1~Yr~ :oho 9 4.3 / C] ° %130.05 ~97004'20" E 32.61- 36.59 ass \ 13. - F- -14001'30 10 10.31 19.177 Lo 5. 11 25 982.8 985.0 v~ 5, x 0 6 / X980.9 i • 0,883 330 I R=55.00 ~ 0) h\ ^ ^ LU III arnrn ~ J 979.2 x 974.7 I Q W F- / /00 Q j~p O II II O Q 3 _ O o I I Z J i Q0_ CL 50 a_= 985.9 2.0~ \ \ O O L- _ (jL0_ V CJ O ;P X 9, ° \ c~ \S 0 M 0` 1 F III o C> U) 0 C> 0_1 iNj N c`~ v? ` xs80.4 8- II W E LI j Z 985.13x 514 S8 a I O d00 _ ry "0" LL, 510 _j LO 9 "6/ / M 1513 `w In 25 I tsts - - _i V LU V, ELEC. '0 v 978.8 Lo 9-74.8 f -31.40- - 37.16 - soe - 159.78 S89047'1 0"W 974.9 CD -r L-- O - 25.0-- 0) oD Z w . b 15.0 10.0 N X= W c~ DIVIS"' -_j PROPOSED HOUSE = 1,855 SQ.FT. OR 13.0% OF LOT AREA DRIVEWAY = 600 SQ. FT. o SAN. SERVICE INVERT LOT 10 14,286 SQ. FT. ELEV.= TO BE FIELD DETERMINED BY CLIENT Scale: 1"=30' Page 2 of 3 James R. Hill, Inc. ll0 /G 3 RECEIVED New Construction Energy Code Compliance Certificate MAY 212013 Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location Date Certificate Posted inside the building. The certificate shall be completed by the builder and shall list information and values of _ components listed in Table N1101.8. 5/8/13 l Z lL tIlS ZIJ n Mailin Address of the Dweltina or n.VetGng Unit City U [111E'Iij81T1 4924 WHISPERING WAY CAPITANI Eagan, MN -MDrIGCOWMTO MN License Number Vennehjem Building Corp. BC108964 THERMAL ENVELOPE RADON SYSTEM o Type: Check All That Apply X Passive (No Fan) v H Active (GYith fmr and nionometer or w a ar other system monitoring device ? W rA a~ U a v G Z ° a w > v Insulation Location • ° o v O o o o a ° cl T F Z ir, w wo wo ao ao Other Please Describe Here Below Entire Slab X Foundation Wall - unfinished areas / utility R10 X Thermax (exposed) Foundation Wall - furred wall areas R10 X 2" in furred stud spaces Perimeter of Slab on Grade X Rim Joist (Foundation) R13.4 X Interior Rim Joist (I" Floor+) R13.4 X Interior Wall R19 X Ceiling, flat " R44 X Ceiling, vaulted X Bay Windows or cantilevered areas R43 X X R30 Batt Insul. + 2" SPRAY FOAM Room over garage FLOOR R43 X X R30 Batt Insul. + 2" SPRAY FOAM Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Ave. U-Factor (excludes skylights & one door) U: 028 X Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.32 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type Natural Gas Electric Electric Passive Manufacturer LENNOX RHEEM LENNOX Powered ML193UH090XP48 Interlocked with exhaust device. Model C RHE- PR052-2 3ACX-036-230-13 Describe: 88,000 Capacity in 50 Gal Output in 3 TON Other, describe: Rating or Size BTUS: Gallons: Tons: heat 65,923 treat Location of duct or system: Structure's Calculated Loss: Gain: 12fil AFUE 93% SEER: 13.00 or IISPF% Calcutated 32,199 Efficiency cooling load: Cfm's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech. code Select Type Passive X Heat Recover Ventilator (HRV) Capacity in efms: Low: 1 17 High: 189 Other, describe: Energy Recover Ventilator (ERV) Capacity in elms: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms: N/A Location of fan(s), describe: Cfrn's Capacity continuous ventilation rate in cfms: "round duct OR FLEX Total ventilation (intermittent + continuous) rate in cfms: "metal duct IL Created by BAM version 052009 ~'C~I~FfJ a$b Meridian Energy Products Load Short Form Jo Date: Mw b: 19' 13 Entire House MAY 21 '2013 BY, ENERTECH Jz 1t/// f~L/) For: Capitani, Anne and Rick 4924 Whispering Way, Eagan, MN Design Information Htg Clg Infiltnatlon Outside db (°F) -15 88 Method Simplified Inside db (°F) 70 72 Construction quality rigid Design TD (`F) 85 16 Fireplaces Daily range - M Inside humidity (#/6) 40 0 Moisture difference (grub) 43 38 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade MERIT 90 Trade ADP Model ML193UH090XP48C--* Cord 13ACX-036-230-13 AHRI ref 4792309 Coil L*19/36S9++TD AHRI ref 3852006 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating Input 88000 MBtuh Sensible cooling 23940 Bt Heating output 83000 Btuh Latent Coding 10260 Bit 1 Temperature rise 68 cF Total coding 34200 Bt Actual air flow 1140 cfm Actual airflow 1140 cf Air flow factor 0.020 efro/Stuh Air flow factor 0.041 cf Btuh Static pressure 0 In H2O Static pressure 0 in 1120 Space thermostat Load sensible heat ratio 0.85 ROOM NAME Area Htg load Clg load Htg AVF CI F {ft2} {Btuh} (Btuh) {cfm} (cf }AV Future Basemen 959 13426 5624 265 230 Entry Level 10}8 12503 5345 247 218 B-fast Nook 65 2947 2601 58 103 FP 6 550 115 11 5 Upper Level 1008 9908 5923 196 242 Over Garage 656 18425 8314 364 339 Entire Huse 3702 57759 27921 1140 1140 Other equip loads 8164 1291 Equip. @ 0.93 RSM 27138 Latent codling 5031 TOTALS 3702 !65923 32199 1140 1144 Sotd/rt.110 Mu" Aawa ba~► manually ovorrtdden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WrI htQft20t ay-0213:12:42 i' RIOM- e0 Universal 2012 12.0.13 RSU02669 Pape 1 C:1UsersWeff\DocumentatW Nhtsoft HVAC\Setter Air, Capkani.rop Cale = MJ8 Front Door faces: Meridian Energy Products Building Analysis RFCFIVED Job. Date: Mar 19, S Entire House MAY 21 '7013 By. ENERTEGH . R ii/// s'r Project Information Far: C 'tans, Anne and Rick 4Z Whispering Way, Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Paul Int'l Arp, MN, US Inter temperature (OF) 70 72 Elevation: 837 ft Latitude: 4511N 16 ai Design TD h~umic ty {°%e} 40 50 Outdoor: %bb Heating Coolin Moisture difference {grub} 43.1 37.9 D -1 88Infiltration: Dal18 { M Method Simplified Wet - 72 Construction quality Tight Winmph} 15.0 7.5 Fireplaces 0 eatinc Component Btuh1ft2 Btuh % of load Walls 6.7 24786 37.6 f Glazing 23.7 8135 13.9 Doors 22.8 658 1.5 Ceilings 1.9 3244 4.9 Infiltration 1.7 6410 9.7 Ducts 10262 15.6 Piping 0 0 Humidification 0 0 Ad uss m~ eents 81604 12.4 Total 65923 100.0 • Cam BtutVft2 Stuh % of load Walls 1.7 6157 21.1 Glazing 38.0 14664 50.2 Doors 7.6 321 1.1 Ceilings 1.1 1986 6.8 Floors 0.1 177 0.6 Infiltration 0.2 646 2.2 Dots 3971 13.6 Ventilation 1291 4.4 Internal gains 0 0 Adjustments 0 0 Total 29212 100.0 Latent Codling load 5061 Stuh Overall U•value - 0.065 Btuhlft2-°F Data entries checked. 8otdltbtto vatuea have been remauatty owerrtdden wrighi soft` 2013- -0213.!2:42 FtiOht-Suited Universal 2012 12.0.13 RStJ02t3B9 ~ 1 CAUser.WettlDocurnerrta Wrightsoft HVAC18etter Air, Ca0anl.np Cale . MJ& Front Door faces: Meridian Energy Products Component Constructions ,lob: Component Constructions MAY 21' 16~. tea#e: fear 19, 20 3 . Entire House ENERTECH n iz y~sr~ Project Information For:. Otani, Anne and Rick 4924 Whispering Way, Eagan, MN Design Conditions Location: Indoor: Heating Cooling Minneapolis-St Raul Int'I Arp, MN, US Indoor temperature {;F} 70 72 Elevation: 837 it Design TD (OF) 85 16 Latitude: 45N Relative humidity {'lo) 40 50 Outdoo D~ r: bulb { °F} Heatin~g✓ Cooling / Moisture difference (grub) 43.1 37,9 88 ✓ Infiltration: Daily range (OF) - 18 (M } Method Simplified Wet bulb (T) - 72 Construction quality flight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area 1.1-value lnsul R H19 HTM Loss Clo M Gain ftl BwhV-IF n-F ,n ,h& h aw Ap sa,n walls 12E-Osw: Frm wall, stucco ext, 112" wood sh r-19 av ins, 112 n 321 0.068 19.0 5.78 1856 1. 423 gypsum bard int fnsh, 2"x6" wood frm a 541 0.068 19.0 5,78 3127 1, 712 s 628 0.068 19.0 5,78 3630 1. 826 w 559 0.068 18.0 5.78 3230 1: 735 all 2049 0,068 19.0 5.78 11844 1. 2696 wall, heavy dry or light damp sal, 2"x4" wood int frm, concrete wall, n 342 0.090 10.0 7.65 2616 2. 850 r- t 8" #hk: Bg h7 dry or light damp sal, 2"x4" woos! Int a 243 0.090 10.0 7.65 1859 2. 604 rete wal r-10 , 8" thk s 229 0.090 10.0 7.65 1752 2. 569 w 262 0.090 10.0 7.65 2004 2. 651 all 1076 0.090 10.0 7.65 8231 2. 2675 Bg wall, heavy dry or light damp soil, 2"x4" wood Int frm, concrete wall, a 80 0.099 10.0 8.41 673 1. 106 r-10 ins, 8" ft w 1, heavy dry or light damp soil, 2"x4" wood Int s 96 O.t~9 10.0 8.41 848 1. 127 frm, concrete wal r-10 ire, 6" #hk all 176 0.099 10.0 8.41 1481 t, 233 12E-Osw: Frm wall, 1/2" wood sh r-19 av ins, 2"x6" wood frm s 5 0.068 19.0 5.78 29 1. 7 w 17 0.068 18.0 5.78 98 1. 22 all 22 0.068 19.0 5.78 127 1. 29 Partitions 12E-Osw: Frm wall, stucco e , r-19 av ins, 518" gypsum board Int 351 0.068 19.0 8.84 3103 1. 525 fnsh, 2"x6" wood frm Windows 2 glazing, cir low-e outs, air gas, vnl frm mat, clr lnnr, 112" gap, 114" a 24 0.270 0 23.0 539 34. 802 thk: 2 glazing, cir low-9 outr, air gas, vnl frm mat, clr innr,1W gap, a 108 0.280 0 23.8 2577 34. 3714 114" thk; NFRC rated (SHGC-0.32) a 10 0.280 0 23.8 238 19. 193 w 60 0.270 0 23.0 1377 34. 2049 w 130 0280 0 23.8 3098 34. 4464 w 42 0.280 0 23.8 1000 34. 1441 w 12 0.300 0 25.5 306 34. 415 all 386 0.300 0 23.7 9135 33. 13079 . stvr hfiaoft 2013-Ma -oa 1312:42 Right-SukeD UnlvwsaJ 2Dl212.0.13 RSU P CA1JswstJeff Documents\WrWftoft MvAC\Better Air, Capitarv.rup Coo - MJ8 Ftatt Door faces: ace 1 Coors Door, mO pur core type: Door, mtl pur care type n 20 0;300 10.6 25.5 606 8 53 169 e 22 0.240 10.5 20.4 .452 6. 181 • all 42 0.240 10,5 22.8 958 7 821 Collings 1611-44ad: Attic ceiling, asphalt shingles roof m r-44 ail ins, 518" 6 0.02+2 44.0 1.87 11 1. 9 gypsum bard Int finsh 1729 0.022 44.0 1.87 3233 1. 4 1976 all 1735 0.022 44.0 1.87 3244 1.4 1986 Floors 21 A-28t: Bg fluor, heavy dry or light damp soil, 6.6 depth 1079 0.022 0 1.87 2018 0 0 Fir floor, frm fir, 12" thkns, carpet fir fnsh, r-43 cav ins, tight: Fir floor, 656 0.049 48.0 1.44 947 0. 7 177 frm f1r,12' thkns, carpet fir fns , r- av Ins, tight ?i-:rcivpn- MAY 21 '?3 a wC htsof 2013-M -0213:12:42 Right-Soft O UnNersai 2012120.13 RSUMM Page 2 G:tUserWethc urnentslVVrightsott HVAC1Batter Air Gapitani,fto Calc . MJS Front Door faces: Meridian Energy Products Prc ect Summa 7 r- l v c n Job: Data. Mar 19, Entire House MAY 21 '7013 By. 20 3 ENERTECH Project Information For: C tarsi, Anne and Rick 49 Whispering Way, Eagan, MN Notes: Design Information Weather: Minneapolis-St Paul Int'I Arp, MN, US Winter Design Conditions Summer Design Conditions Outside db •15 °F ~ outside db 88 T ✓ Inside db 70 °F Inside db 72 T Design TD 85 OF Design TD 16 O Dally r M Relative tumiccity 50 % Moisture difference 38 gr Heating Summary Sensible Cording Equipment Lead zing Structure 47498 Btuh Structure 23950 Bt Ducts 10262 Btuh Ducts 3971 Bt Central vent (180 cfm) 8164 Btuh Cenral vent (152 cfm) 1291 Bt Humidification 0 Btuh Blower 0 Bt Piping 0 Btuh Equipment load to Use manufacturer's data n Rate/swing multi ier 0.93 Infiltration Equipment sensie load 27138 Bt Method Simplified Latent Coolie Equipment Load Si In g Construction quality Tight Fireplaces 0 Structure 951 Bt Ducts 3W BtL 1 Area (ft2 Heating 02 3702 Equipmevntt later to ) 3805 Bt Volume (ft3) 32614 32614 Air c hour 0.13 0.07 Equipment total load 32199 Equiv. AVF 71 38 Req. total capacity at 0.70 SHR ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade MERIT 90 Trade ADP Model ML193UH090XP48G * Cond 13ACX-036 230-13 AHRI ref 4792309 coil L*1gt36S9++TD AHRI ref 3852006 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating Input 88000 MBtuh Sensible cooling 23940 Btu Heating output 83000 Btuh Latent cooling 10260 Btu Temperature rise 68 OF Total codling 34200 Btu Actual air flow 1140 cfm Actual air flow 1140 of Air flow factor 0.020 cfmBtuh Air flow factor 0.041 cfrr, Btuh Static pressure 0 In H2O Static pressure 0 in 20 Space thermostat Load sensible heat ratio 0.85 Botdlttatta vatu" have been nmuatty owrtddar Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a Wt" htSQfsi' 2413-M -0213:12.42 • • - Right-SuRsO Universal 2412 12.4.13 ASU02$89 Page 1 CAUserstJettlDeaument$ WdgMsoft HVACl6etterAir, CaapkwLn* Calo.MJ8 Front Door tam: u City of Eapn Address: 4924 Whispering Way Zip: 55122 Permit 110163 The following items were / were not completed at the Final Inspection on: Complete Incomplete Comments Final grade - 6" from siding Permanent steps - Garage Permanent steps - Main Entry Permanent Driveway Permanent Gas Retaining Wall or 3:1 Max Slope N f Sod / Seeded Lawn Trail / Curb Damage Porch Lower Level Finish C Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: fe L:~L- icW-e L, (c GABuilding InspectionsTORMS\Checklists f7t4 1 rte( .� rito,a r ism-7a 1 ,l v * Fee -5�� e I AMORY 3830 PILOT 10408 ROAD i ,MN 56122-1810 F I (681)x` a :(851)4644538 iF4X,(651)875-5894 JAN 0 9 L_Uiy I ant, I 2019 RESIDENTIAL BUILDING ! T APPLICATION Doty silo Ar s;,.It`tZzt c,/ii,i•AftvZ /-1JiV Unit ArmfU. 651-485-6286 4924 a4lisperax;way i owner /City r V Contractor 1 -1.1. r ., basement finish i a Type of Work f S4flk art's >, Y I N: Brand Co Chase ---1 po Box 546 prior lake mrt ... PhoneMeta- art 9�- ° ` , ;. m brad m afn inc. t k rr�err 1:4*340 i • taut t�irrff�etrtai , If the project Is pt front lead certification, explainwhy • house is 5 years old • Bv«fi ate/3 COMPLETE TINS AREA ONLY IF CONSTRUCTING A NEW B . . In fife Wok 12 moidtte.has tt)R City of a permit for a spotter elan based on a missal plan? f {( g I yes, of 5 1 Mechanicalccinituctor Phone: Fir. C Phone:Nor " iiiie' , ttr t+weasewi rN+r ri b:ber `. a yl�f�► QIio o—t-"a4---aWereiaaariaiayas you subset*.toaroosts*}errsiactrtatle nradtositas than*hi.Oky of proposed onnbartasoby signing upfor an*owlupdateon On city* tf�l a dEa Y•.„'"Kd.9Ls. :d.k;. ,bi�'s�$�„a-, „'� ardedor wog as oelyd W a pent*;issued in accordance whit cher Minnesota Sties artbe conntssidwind*110 dart 84 pan*nottmane. EkieegrWund 44 hours before you 1 notary anatowardp.that Sas traoristatan Is complete and `s ate work will be ic oontormattor with the annulment and codes of the Coy of Elton;that I urtdorstand fais is Oa*paw&Irra nay an apploaton for a and is net in start without*writ Olaf the work will be 0 no a avant rt i tri of a and of . ex it . . Applicants i ..,.. n . ilisrunure . i-17 y Gv hi_s pe!-a ,�.. (./ii /'S-S ( DO NOT WRITE BELOW 11118 LINE . � 1 -- F ��► � ��MeV* — to!. owls ramey Garage Porch$4olloci Extedur ) . Dock Porch ) — iMeteHeneote Ot of__Pee R Pool Accessory 4,04 id& ! ;t." New interior improvement Demoilsh Sulkies' Ad Move Building Demolish Interior Aprwstion __... Fire Repair Windows _ Demolish Foundadon _ Repine Repair Evens Window Water Denims RelaWing Weil ien,of aeths **gtva.PCA hoodotd to aooettsot PEWUPignit Ysi /1 000 OcCuPancy _ 7.4E 1. ACs system _ Plan Review Edition 1704 SAC Units ^ (25%_ 1 00,40jd Census Code 4 34 Sar Booster Pump •of Unite I re Feet _ PRY '^ f Buildings 1 Longth Fite Suppression Required Type at Construction 1 Width , 1. Ia E L , €# 0:,=t .; B }: Meter Facitin.Pecli4 CICO.Required Footing'(Adtallon) I No C.O.Required Fooldigion ,FOunthdlon&gore Ba ..A-^ HVAC Service Test Gas Liver Air That__..Hood ..„..ice y ... Pool:11.1.0101.Footings ,.....Air/Gas I Framing s r.......I HourDrain Tile Fireplace:_ARough In „LAir Test nal Siding: �._Stucco Lath Stone Lath _..Einca. EFIS ,,,* Insulation Windows Sheathing Retaining Wail: Footings ,.Backfill Final Sheet/volt Radon Control fire Woho Fire Suppression:„ Rough In_Final Braced Wane Erosion Control Show.Pon / Other: / ' 4. Reviewed Sy: f ,/ i Building losPector 47,0 *:,' Q: E �'t�FEES ... � � Sumharge Plan i� eO a @, ota / j q.=_ aces SAC OW SAC Ccompotkin Chary, s&w Permit&Surcharge Treatmtint Plant Copies a- a; .. 0 TOTAL Page 2of 3 1 REVISOR 1346.6012 1346.6012 IFGC APPENDIX E, WORKSHEET E-1. • IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: (Not fan assisted) & Power Vent 7 ' Btu/hr Water Heater: Draft Hood 1/ Fan Assisted Direct Vent Input: (Not fan assisted) & Power Vent 11/0 Gzj Btu/hr Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. IG a x ie'g g'_ CAS volume: ,//Q ft3 Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/ ' put of all combustion ape '.nces (DO NOT COUNT `► RECT VENT AP' ANCES) Input: Btu/hr Use Standard Metho. column ' Table E-1 to find Total Required Volume (TR TRV: ft3 If CAS Volume ( Step 2) ;reater than TRV then no outdoor openings are needed. If CAS Vo e (from Step 2) is less han TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Copyright©2009 by the Revisor of Statutes, State of Minnesota. All Rights Reserved. 2 REVISOR 1346.6012 Total Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: 110 ©GD Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RVFA: 30°° ft3 Total Btu/hr input of all non-fan-assisted appliances Input: /!in 9 Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) RVNFA: /✓'/f4 ft3 Total Required Volume (TRV) = RVFA + RVNFA RV= + = 3 r�U ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = A./11— / 3 "CO = O. ?oil Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = 1 - 0. 70W = 0. 9G Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: !-r Cx p0 Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per int CAOA = 4/a 06t2 /3000 Btu/hr per in2 = / 3. 3 3 in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = I 3 x 0. 7.96 = 3 .9 b in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) Copyright©2009 by the Revisor of Statutes, State of Minnesota. All Rights Reserved. -3 7 / 3 REVISOR 1346.6012 CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 Minimum CAOA= • 2.J1 in 3 " ,v1/1.4i IIf desired,ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. p2 " J=iiX Statutory Authority: MS s 326B.101; 326B.106; 326B.13 History: 34 SR 537 Published Electronically: October 23, 2009 Copyright©2009 by the Revisor of Statutes, State of Minnesota. All Rights Reserved. For Office Use a�o ` o Permit#: M• �' E AGA N Permit Fee: Cly ol Date Received: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD: (651)454-8535 I FAX: (651)675-5694 Staff: buildinginspectionsacityofeagan.com L 2019 RESIDENTIAL PLUMBING PERMIT APPLICATION Date:;-6-90(9/ Site Address: / V" ( � 1.( "`9 ()-ka Tenant: Suite#: � �tesid40�� ' Name: Phone: � 40IY Address/City/Zip: jacf\I ' . , Name: JO(././I (A- �� uckitA {"- License#: % c o rd itis Address: 9'? V� I(7 O u)JC --vs City:/4/01v 1��k Conrar ' State: Zip: �? 7 i Phone: (9/ 2— ? / —594A1 310!q l L� f,-?-41,45-10741-14:7;7 Contact: Email: 50 U -C(rf 2 gt/0 Crl'I'e c CC 7 i ,m, „i Type of Work , New Replacement —Repair —Rebuild Modify Space Work in R.O.W. . — — — . : Description of work: J6-0E RESIDENTIAL a 5. Water Heater Water Softener Lawn Irrigation( RPZ/ PVB) It Type 3 Add Plumbing Fixtures( Main/ Lower Level) Septic System New Water Turnaround Abandonment RESIDENTIAL FEES: $60.00 Water Heater, Water Softener, or Water Heater and Softener(includes State Surcharge) $60.00 Lawn Irrigation(includes State Surcharge) $60.00 Add Plumbing Fixtures, Septic System Abandonment,Water Turnaround*(includes State Surcharge) *Water Turnaround(add$280.00 if a 3/4"meter is required) $115.00 Septic System New(includes County fee and State Surcharge) TOTAL FEES $ CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeaaan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be i ••nf• a - with the ordinan ,and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and • is • o - •rt wi out a ped it; that the work will be in accordance with the approved plan in the case of work which requires a review and appro - • pl- x A-,S\C tlt �e A.,// Li PP A licant s Printed Name i ant's Signature P �, FOR,6-FM ,e yam, ii X1,00 Reviewed ili, 4yt 9P Required tripe:!iortskir , k Viand,: ,vn r t ugh In A�irTest Gas Test "Fetal MeterFRelate : 0.Mem I ac io Read k Manometer0 Staff: