Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
963 Monarch Tr
f 1i0~6~U~ I Use BLUE or BLACK Ink For Office Use I j Permit 1 10 Clay of Ea~a~ Permit Fee: U 9~ I 3830 Pilot Knob Road Eagan MN 55122 I Date Received: 41~° 17 3 1 Phone: (651) 675-5675 Fax: (651) 675-5694 I Staff: 1 - - - - - - - - - - - - - - - - S W t t ! ' 2013 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 4-7 11,3 Site Address: -q6 5 //f ~ f D0all-C k -T-Vlot~1] Unit Name: LQAA4.✓ Cora Phone: 152- 2Y?-,3X6 Resident) / i 'r Owner Address / City / Zip: /0305 SO AVe. Al ~GAWOU{~C . MAI 55Vf'(0 Applicant is: Owner Contractor -7 , Description of work: /ULo~tJ ~ovt,S'F'✓'+~CtOyt n~ ) ~~~r7 Type of Work 1 /,1 ~ Construction Cost: I (po ) ©U'~1 Multi-Family Building: (Yes No x ) Company: Lzyy m q t ` C,oI~P . Contact: A471~- Aewl and Contractor Address: f-79 ~Ylh1 P~"` City: 50-14,K I Ili %-J State: MN Zip: 5512-3 Phone: 612 - 9178 " 779~P License ~'7l3 Lead Certificate If the project is exempt from lead certification, please explain why: (see Page 3 for additional information) COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan Issued a permit for a~jsimilar plan based on a master plan? t Xyes _No If yes, date and address of master plan: ~Qy SQ w/ w s,5 7 Kam)' k)es+ Licensed Plumber: Ebtvtdev M& / r 114014 biAl q Phone: 952- yyS- of Mechanical Contractor: Phone: Sewer & Water Contractor: y-k-tPhone: GS! - 2V& -l 312 NOTE. Plans and supporting docu ents that you submit are considered to be public information. Portions of< the information may be classified as non-public if you provide specific reasons that would permit the City to conclude that the are trade secrets. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.oooherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit Issuance. x A400 *M*r7d - x my?!n~ Applicant's Printed Name Applicant's Signature Page 1 of 3 DO NOT WRITE BELOW THIS LINE SUB TYPES _ Foundation _ Fireplace Porch (3-Season) _ Storm Damage Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family) _ Multi _ Deck _ Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi) _ 01 of _ Plex _ Lower Level - Pool _ Miscellaneous Accessory Building WORK TYPES New _ Interior Improvement _ Siding _ Demolish Building* Addition - Move Building _ Reroof _ Demolish Interior Alteration - Fire Repair _ Windows _ Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building - give PCA handout to applicant DESCRIPTION Valuation 336 Occupancy MCES System Plan Review Code Edition ~ SAC Units (25%_ 100%__) Zoning City Water Census Code jai Stories Booster Pump 'de` # of Units / Square Feet PRV ,vb # of Buildings / Length 3G Fire Sprinklers yp Type of Construction Width q0 REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck)L Final / C.O. Required Footings (Addition) Final / No C.O. Required Foundation HVAC _ Gas Service Test Gas Line Air Test Drain Tile Other: Roof: Ice & Water It- Final Pool: -Footings Air/Gas Tests -Final Framing Siding: -Stucco Lath Stone Lath -Brick Fireplace:,Rough In Air Test Final Windows Insulation Retaining Wall: _ Footings _ Backfill _ Final Sheathing Radon Control Sheetrock Erosion Control Reviewed By: , Building Inspector RESIDENTIAL FEES U•✓ J4v 11, 3 A$ 1 Base Fee oZ y ~G ;v 19 G 7 G ?A V° Surcharge P Plan Review GQ- s~ 1 D9G *J _ ,ao MCES SAC S 1.3 go City SAC 9 $ 9 v/ Utility Connection Charge S&W Permit & Surcharge °G Treatment Plant Copies q ~7 TOTAL Page 2 of 3 i New Construction Energy Code Compliance Certificate Per N 1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside Date Certificate Posted the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N 1101.5. alalang Address of the Dwelling or Divelfing Unit City Sinclair 963 MONARCH TRAIL EAGAN Name of ttesidential Contractor atN License Number THERMAL ENVELOPE Type: Check All That Apply X Passive (No Fan) w O ~ T a Active (0th fan acrd monomeler or F B ay, other system monitoring device) . W L. *a T a° 3 w ca a Q m m ~ U ~ c ~ o ui o aCi :o ~ ~ Insulation Location c z U Oa w - ° ~ chi v ;t7 q C 67 C] F z uA', r w° r° i2 Other Please Describe Here Below Entire Slab X Foundation Wall 0 INTERIOR Perlrliefer of Slab an Grade . X Rim Joist (Foundation) 10 INTERIOR lum Joist `(0: Floor+) 10 'INTERIOR Wall 21 Ceiling, flat. ; 44 Ceilln , YAulted t44 5 Ba . Wrndoivs r cantilevered areas Bonus room over garage Descrtbe other insulated areas 'i Windows & Doors bleating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (exchrdes skylights and one door) U: 0.28 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.29 do" X R-value R-8 MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not r uired er mech. code Fuel Type Natural Gas Natural Gas Electric Passive Manufacturer Lennox AO Smith Lennox Powered Interlocked with exhaust device. Model ML193UH070XP368 " GPVH50N -13ACX-030-230: Describe: Input in 88,000 Capacity in so Output in 3 Other, describe: Rating or Size BTUS: Gallons: Tons: !teat Loss: Heat GO 20641: Location of duct or system: 46- : Structure's Calculated 60. ' AFUE Tr -14 SEER: 13 IiSPF% 93 Calculated Efficiency cooling load: Cfin's PLAN SINCLAIR ^ round duct OR 4Mech anical Ventilation System " metal duct be any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type heat pump with gas back-up furnace): & requiper mech. code Type X Passive eat Recover Ventilator (HRV) Capacit in cfins: #20c.rdirou, w: Hi h: Other, describe: ergy Recover Ventilator (ERV) Capacity in cfins: High: Location of duct or system: ntinuous exhausting fan(s) rated capacity in cfins: fans on low TOTAL 90CFMS Mechanical Room Location of fan(s), describe: Owners bath, Main Bath s Capacity continuous ventilation rate in cfms: 90 6" fInsulated Flex Total ventilation (intermittent + continuous) rate in cfms: 465 etal duct Created by BAM version 052009 PLAN VI F COMPLIANCE IT AIRCRAFT NOISE ORDINANCE Compliance with Procedures to Ensure Submitter: Noise Impact Area Adequate Noise Attenuation: Lennar Airport - MSP International Exterior wall construction: 16305 36th Ave. No. Noise Zone - 4 LP Smart Board Suite 600 15/32" sheathing Plymouth, MN 55446 New Infill Residence is a "COND" Tyvek wrap 952-249-3000 use in Noise Zone 4 2x6 studs 16" O.C. R-21 batt insulation with 1/2" gypsum board I Roof Construction: Plan Reviewed: d/077 1,4! O r- Peaked roof with manufactured trusses 24" O.C. 9lp3 mo1vi4,c'Grq j;i*9z-4_ Roof vents Shingles I Information Submitted: 15# felt Annotated architectural drawings including: 1/2 sheathing Blown insulation R-44 Windows: Atrium 5/8" gypsum board Swinging Patio Doors: Atrium Entry Doors: Therma Tru Mechanical Ventilation System: Skylights: N/A 3-ton central air conditioning unit Compliance with STC Requirements: Window, Door Frame, Perimeter and Other Seals: All window and door openings are to be caulked Average window/wall area for exterior wall: /2r Q with butyl-based caulk With this window/wall area ratio and STC 40 walls, windows Fireplace Chimney Cap: with an STC 30 can be used to meet the noise reduction Built-in flue damper, chimney cap, glass enclosed requirements; Ventilation Duct Exterior Wall Penetrations: Summa : All exterior ducts will have bends as required by the ordinance Other measures including duct bends and caulking are being taken to ensure minimum transmission of noise through the Door and Window Construction: exterior building shell so that the construction should meet Windows: Atrium (30 STC) the compatibility guidelines. Sliding Patio Doors: Atrium (30 STC) Therefore, the materials and construction as proposed should meet the requirements of the Eagan aircraft noise ordinance, Entry Doors: Therma Tru (29 STC) i Skylights: N/A Review Completed (date): / lfV e'i0 Other Exterior Wall Penetrations: Review Completed by: Tom Tamte Sill sealer between plates and blocks Ventilation, Makeup and Combustion Air Calculations Submittal Form For New Dwellings These blank submittal forms and instructions are available at the City website and at City Hall. The completed form must be submit- ted in dupljcate at the'time;of appliotlon of a mechanical permit for new construction. Additional forms may be downloaded and printed at: Site address l Date 16 2 Contractor Completed y~ Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area Including Basement-finished or unfinished) sw Total required ventilation ' U Number of bedrooms Continuous ventilation d Directions - Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. The table and equation are below. Table N1104.2 Total and Continuous Ventilation Rates (in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space (in Total/ Total/ Total/ Total/ Total/ Total/ sq. ft.) continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 .15.01-2000 70/40 85/43 100/50 115/58 130/65 145/73 20012500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-350.0 100/50 115/58 1 6 145/73 16 $0 175/88 35014000 110/55 125/63 155/78 170 85 185/93 4001-4500 120/60 135/68 1 165/83 180 90 195/98 4561-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 21S/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space) t [15 x (number of bedrooms + 1)) = Total ventilation rate (cfm)" Total ventilation -The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, for each one-hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventila- tors (ERV) the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a con- tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. I G:ISAFETYUK%Vent-makeup-comb air submittal (2).docx Page 1 of 6 Section B Ventilation Method (Choose either balanced or exhaust only) Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recov- Exhaust only F",3 ery Ventilator) - cfm of unit in low must not exceed continuous venti- Continuous fan rating in cf (""4. ,G~~ lation rating by more than 100%. "/a / 9-t' f./.w Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed p continuous ventilation rating by more than 10096) 7~)~ iw Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts. Low c Lm airflow must be equal to or greater than the required continuous ventilation rate and less than 100% greater than the continuous rate. (For Instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Schedule Description Location Continuous Intermittent 1 .rN, FG., I mot, , sc> V" FO L Ch ~V I So Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low c fm air rating and less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls (Describe operation and control of the continuous and Intermittent ventilation Directions -Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and inspectors to verify design-and installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. 7f - exhaust fans are used for building ventilation, describe the operation and location of any controls, Indicators and legends. If an ERV or HRV is to be installed, describe how it will be Installed. If it will be connected and interfaced with the air handling equipment, please describe such connections as detailed in the manufactures' installation instructions. If the installation Instructions require or recommend the equipment to be Interlocked with the air handling equipment for proper operation, such interconnection shall be made and described. Section E Make-up air Passive (determined from calculations from Table 501.3.1) Powered (determined from calculations from Table 501.3.1) Interlocked with exhaust device (determined from calculation from Table S01.3.1) Other, describe: Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm size and type (round, rectangular, flex or rigid) (NR means not required) Page 2 of 6 Directions - in order to determine the makeup air, Table 501.3.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re- quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flexor rigid) to the last line of section D. The make-up air supply must be installed per iMC 501.3.2.3. Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances, see KAIR method for calculations} One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical- vent or direct vent ap- assisted appliances and gas or oil appliance or ly vented gas or oil pliances or no combus- power vent or direct vent one solid fuel appliance appliances or solid fuel tion appliances appliances appliances Column C Column 0 Column A Column 8 1. - a) pressure factor 0.15 0.09 0.06 0.03 (cfm/sf) b) conditioned floor area (sf) (including 5 unfinished basements) g J Estimated House infiltration (cfm); I1a x lb) S'3'7 2. Exhaust Capacity a) continuous exhaust-only ventilation system (cfm); (not applicable to ba- '70 lanced ventilation systems such as HRV) b) clothes dryer (cfm) 135 135 135 135 c) 80% of largest exhaust rating (cfm); ~CI~ x Kitchen hood typically (not applicable if recirculating system 'n or If powered makeup air is electrically [7`' U Interlocked and match to exhaust) d) 80% of next largest exhaust rating (cfm); bath fan typically Not (not applicable if recirculating system or if powered makeup air Is electrically Applicable interlocked and matched to exhaust) Total Exhaust Capacity (cfm); [2a + 2b +2c + 2d 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above) 57 b) estimated house infiltration (from above) 3 7 Makeup Air Quantity (cfm); / [3a-3b) (if value is negative, no makeup air is Ne;~. needed 4. For makeup Air Opening Siting, refer to Table 501.4.2 /VA A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) 8. Use this column if there Is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be in- cluded.) C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or If there are atmospherically vented gas or oil appliances and solid fuel appliances. Page 3 of 6 Makeup Air Opening Table for New and Existing Dwelling Table 501.3.2 One or multiple power One or multiple fan- One atmospherically Multiple atmospherically vent, direct vent ap- assisted appliances and vented gas or oil ap- vented gas or oil ap- Duct di- pliances, or no combus- power vent or direct pliance or one solid fuel pliances or solid fuel ameter tion appliances vent appliances appliance appliances Column A Column B Column C Column 0 Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47 - 69 29 - 42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233- 317 144-195 loo-135 62 - 83 8 Passive opening 318-419 196-258 136-179 84-110 9 w/motorized damper Passive opening 420-539 259-332 180-230 111-142 10 w/motorized damper Passive opening 540- 679 17333 - 419 231- 290 143 -179 11 w/motorized damper Powered makeup air >679 >419 >290 >379 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct Is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted, C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Sections F Combustion air Not required per mechanical code (No atmospheric or power vented appliances) x Passive (see IFGC Appendix E, Worksheet E-1) Size and type " A Other, describe: Explanation - if no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1(see below). Please enter size and type. Combus- tion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. Page 4 of 6 Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction, 4b of step 4 is required to be filled out. IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combustion appliance information. Furnace/Boiler: Draft Hood " Fan Assisted X Direct Vent Input: Btu/hr or Power Vent Water Heater: Draft Hood X Fan Assisted Direct Vent input: _ Sr-) Ct)O Btu/hr or Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft' LxWxH L W H Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been Incorporated Into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH Is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. (00 NOT COUNT DIRECT VENT APPLIANCES) 4a. Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft' Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP S. 4b. Known Air Infiltration Rate (KAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: S 0~ 000 Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA 3c 7 Sy ft- Required Volume Fan Assisted (RVFA) Total Btu/hr Input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: ft' Required Volume Natural draft appliances (RVNDA) Total Required Volume (TRV) = RVFA+ RVNDA TRV = + - 3r -)5,0 TRV ft' If CAS Volume (from Step 2) Is greater than TRV then no outdoor openings are needed. If CAS Volume (from Ste 2) is less than TRV then go to STEP S. Step S: Calculate the ratio of available Interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio= Sot 8 / 3 7 Sp Step 6: Calculate Reduction Factor (RF). RF - i minus Ratio RF =1- J Y - Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS input: S-dl C106 Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in' CAOA = S'tl c,&.., / 3000 Btu/hr per in' = 1 ~o. 7 In' Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = (o. b1 x s _ 19,3Y 1 int Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD =1.13 multiplied by the square root of Minimum CAOA CAOD =1.13 V Minimum CAOA = L~ Q in. diameter go u one Inch in size if using flex duct 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304. Page 5 of 6 QQ~~ N C C~CL 0 ~o o m co o o 4 M fA Su (J N r v v l -n w N p '3 4 N ~ (D •1 lt'.CM 1111 N (A (A co W co v N (/j N (A Ul " (D O r r C2 Y o 2 Tim 0 2 T , z ~ w z . o~ 0 Z. C) O O O O z CA Z. _ D p w D qt v p ' z 't3 Crn~ N N N N D N 00 N N N N ` ~ -I -t O O o o O O o o ,D o 0 o Z T T -n rf?1 (n 0 (n D 0 v 0 G) m (n cn G) D ~ G 2 2 r 2 z A N C?_ m z z z rn z z Z D z wp ~n~ zm G 67 G7 D D 0 -Cj)1 zG) D t D {A Cn Z -f r;v r w i- e m s C 0 r z A -i :0 w m m S z' m D F. m r L7 n ( O r n. rn n 'h G~ o D a o n (_Wr) d w o ~1 fn 'D to m M (n x N CO) 0 CO) n n 0 w 0a m fj) ~v Ul (n n n O •6) Z ! n A Z TI U1 S m"~ `n r Olin (D~ r T D N 'U C co N ~O @ ? D . ca G) m co co N z cn " v D C-) Z ~ N z tin Z Q z w z z z z z z z z z z z Cn i D C, 0 0 0 0 0 0 0 0 0 0 0 mf o z z z z z z z z z z z m m m m m m m m m m m z v+ _ i C) -4 cr) 3 a v a a m w v N r- ,n O Ol 00 o rn O 0) -n X w X X X x z :C1 N X QX~ N N O OD X X C N .P O O CU O O c O I O O • i ~ w -n r- M M W W Z 70 y O m (Q7 j ( W o i x N m O T , N , cn Qo Z A "1 , O C7 'fl 'O 'p X Q Q W O jam" o Q Q Q; D EL -4 C13 °o ✓Z r.L i 1C, rn x F s ~ ~ ~ wf 0: I ~a wri9htsoft° Project Summary Job: Sinclair4007 Date: May 16, 2093 Entire House By: Scott Elander Mechanical Inc. 591 Citation Drive, Shakopee, MN 55379 Phone: 952445-4692 Fax 952-445.7487 Project Information For: 9&3 Ine, 4 -Z,_e,, Notes: Yuii✓ G ow S 7/ St'yp Alt- 09, &co : ay, r12 Design Information Weather: Minneapolis-St. Paul, MN, US Winter Design Conditions Summer Design Conditions Outside db 15 OF Outside db 88 OF Inside db 70 OF Inside db 75 OF Design TD 85 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 26 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 38102 Btuh Structure 20470 Btuh Ducts 757 Btuh Ducts 177 Btuh Central vent (114 cfm) 10351 Btuh Central vent (114 cfm) 1571 Btuh Humidification 8360 Btuh Blower 0 Btuh Piping h Equipment load 57570 Btu Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 20641 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 1846 Btuh Ducts 61 Btuh Heating Cooling Central vent (114 cfm) 1965 Btuh Area (ft') 3584 3584 Equipment latent load 3871 Btuh Volume (ft') 22185 22185 Air changes/hour 0.13 0.07 Equipment total load 24512 Btuh Equiv. AVF (cfm) 48 26 Req. total capacity at 0.70 SHR . Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade MERIT 90 Trade 13ACX SERIES - RFC Model ML193UH070XP36B-* Cond 13ACX-030-230-** AHRI ref 4792133 Coil C33-43*++TDR AHRI ref 5548790 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating input 66000 MBtuh Sensible cooling 20720 Btuh Heating output 62000 Btuh Latent cooling 8880 B#uh I Temperature rise 59 OF Total cooling 29600 Btuh Actual air flow 987 cf Actual . m air flow 987 cfm ~ Air flow factor 0.025 cfm/Btuh Air flow factor 0.048 cfm/Btuh I, Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ~ 2013-May-16 15:24:32 -d- wrightsoft' Right-Suite® Universal 2012 12.1.06 RSU13410 Page 1 ACCA CAUserslscott millardlDesktop%Lennar Sinclairsup Calc = MJ8 Front Door faces: N wrighsoftComponent Constructions Job: Sinctair4007 Date: May 16, 2013 Entire House By: Scott Elander Mechanical Inc. 591 Citation Drive, Shakopee, MN 55379 Phone: 952-445-4692 Fax 952.445-7487 • • e Information For: Design Conditions Location: Indoor: Heating Cooling Minneapolis-St. Paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference (gr/ib) 54.5 26.1 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 19 (M) Method Simplified Wet bulb (°F) - 71 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value insut R Htg HTM Loss Cig HTM Gain fP Btuhfn? 'F fV08luh 8luhm, Btuh DOW Bull Walls 12F-Osw: Frm wall, vnl a r-21 av Ins, 1/2" gypsum board int n 586 0.065 21.0 5.52 3238 0.89 520 fnsh, 2"x6" wood firm a 562 0.065 21.0 5.52 3104 0.89 498 s 540 0.065 21.0 5.52 2983 0.89 479 w 609 0.065 21.0 5.52 3367 0.89 541 all 2297 0.065 21.0 5.53 12691 0.89 2038 _1Sk-10sfc-8: lag wall, heavy dry or light damp soil, concrete wall, n 272 0.050 10.0 4.25 1156 0 0 r-110 ns, 8" thk a 320 0.050 10.0 4.25 1360 0 0 s 272 0.050 10.0 4.25 1156 0 0 w 160 0.050 10.0 4.25 680 0 0 all 1024 0.050 10.0 4.25 4352 0 0 Partitions (none) Windows Stonehaven: VINYL. Insulated Glass Double Hung; NFRC rated n 8 Q2B 0 23.8 190 8.63 69 (SHGC=0.29); 50%a indoor insect screen s 54 0 23.8 1289 16.2 880 w 189 0 23.8 4490 29.1 5496 all 251 0 23.8 5970 25.7 6444 Stonehaven: VINYL Insulated Glass Double Hung; NFRC rated a 12 0.280 0 23.8 286 27.9 334 (SHGC=0.26) e aver: VINYL Insulated Glass Double Hung, NFRC rated a 64 0.280 0 23.8 1527 26.5 1699 (SHGC=0.26); 50% indoor insect screen o even: VINYL Insulated Glass Double Hung; NFRC rated w 42 0.270 0 23.0 964 32.6 1367 (SHGC=0.33); 50% indoor insect screen Doors 11JO: Door, mtl fbrgi type a 42 0.600 6.3 51.0 2142 14.9 626 Ceilings 16CR-4ad: Attic ceiling, asphalt shingles roof ma r-44 c it ins, 1464 0.022 44.0 1.87 2738 0.84 1235 5/8" gypsum board int fnsh 2013-May-16 15:21:32 -~1- wrlghtsoft' Right-Sulte® Universal 2012 12.1.06 RSU1341Q Page 1 ,CA C:1Userslscott mlllardlDesktoplLennar Sinclair.rup Cale = MJ8 Front Door faces: N Floors 20P-38c: Fir floor, frm fir, 12" thkns, carpet fir fnsh r-5 ext ins, r-38 115 0.030 38.0 2.55 293 0.25 29 cav ins, gar ovr 20P-38v: Fir floor, frm fir, 12" thkns, vinyl fir fns r-5 ext ins, r-38 155 0.030 38.0 2.55 395 0.25 39 cav ins, gar ovr 21A-24c: Bg floor, light dry soil, 5' depth, carpet fir fnsh 1122 0.025 0 2.13 2384 0 0 2013-May-16 15:21:32 * wrightSOW RightSuiteV Universal 2012 12.1.06 RSU13410 Page 2 / ~ C:1UsersSscott millarmDesktopli-ennar Sinclair.rup Cale = MJ8 Front Door faces: N LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL:C]~ % RIM K DATE OF SURVEY: JQ )3 LATEST REVISION: a~ c cc t U o z a DOCUMENT STANDARDS ❑ ❑ • Registered Land Surveyor signature and company ❑ ❑ • Building Permit Applicant ,tr 0 0 • Legal description ❑ ❑ • Address ❑ ❑ • North arrow and scale ❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.) 0 0 • Directional drainage arrows with slope/gradient % C~ D 0 • Proposed/existing sewer and water services & invert elevation 0 0 • Street name 0 0 • Driveway (grade & width - in R/W and back of curb, 22' max.) j ❑ ❑ • Lot Square Footage 0 ❑ • Lot Coverage ELEVATIONS Existing 0 ❑ • Property corners 0 O * Top of curb at the driveway and property line extensions ❑ ❑ • Elevations of any existing adjacent homes ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches ❑ ❑ • Waterways (pond, stream, etc.) Proposed ❑ ❑ • Garage floor )z 0 ❑ • Basement floor ❑ 0 • Lowest exposed elevation (walkout/window) 0 0 • Property comers ❑ 0 • Front and rear of home at the foundation PONDING AREA (if applicable) ❑ ❑ • Easement line ❑ ❑ • NWL ❑ 0 • HWL ❑ 0 • Pond # designation 0 0 • Emergency Overflow Elevation 0 0 • Pond/Wetland buffer delineation Y . Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ❑ ❑ • Lot lines/Bearings & dimensions ❑ ❑ • Right-of-way and street width (to back of curb) ❑ 0 • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) ❑ ❑ • Show all easements of rec rd and any City utilities within those easements ❑ ❑ • Setbacks of proposed struct and 'si, a d setback of adjacent existing structures 0 0 • Retaining wall requirements: Reviewed By: L Date G:/FORMS/Building Permit Application` Rev. 11-26-04 Lot 9, Block 2, STONEHAVEN 4TH ADDITION I 0-71 X according to the recorded plat thereof Dakota County, Minnesota 3:1 Maximum Slopes Address: 963 Monarch Trail, Eagan, Minnesota or Retaining Wall Wed House Model: 4007 Elevation: B3 Be Required ~j Buyer: Inventory _ 33.51 ,D S87028'1 9"E i 81.3 881.3 y S 38.85 7 0 - -''8 57 00"E_ _o >s.s rO1^° ilit, 1 (880,2) °sern I 1 - - _ - e^ t and utility r 1 - Per plot Scale: 1 20' S I; 1 5 r- WED " 9 co I DL- I I I X 883.1 X 882.5 EAGAP ~ 01 N EJiiNG DEFE I A I ' INSTALL x I ' PERIM R CONTROL Z NN I 4) N I X-___ cp 00 Z E-- (884.2) Q O (883.9) Q U I 40.00 9.I 1 00 Q l.. 11 / W I Proposed o f «w d fir` N House Igwt+ A /17 Q- vacant o I 8'4„ F B.L.O. ° L- X a z 0-4 U-) I - w 4b1 , d- 10.00 ° ~0 17.50 Garage 1 O ° C) 1 3 od W porch `n l I~'-- (889.2) co m l I 11 (88 .5 885.9 10•50``o° O 1 1 -88s.s 22 00 8es I , Cd L_-----J Benchmark: I X 8 9 .5 mo 0~ - to of spike - (88 1 (88.9 P ) co elevation =885.86 I O I (PROPOSED I Lr) ' DRIVEWAY ` L o} 7.7% Benchmark: _ (D top of spike o - - j- - - - elevation =886.20 (886.0) 885.8 O I (886.3) INSTf' A 9", .w 86.0 S 6' I I CO 6 I j Lot area = 9284 SF ----I-----I-t--I-I---- I 0 452 41 „ House area = 1792 SF 1 I R= Porch area = 1D2 SF ~ o C0 ` Sidewalk area = 55 SF 6 '94 Driveway area = 812 SF Impervious Coverage =29.7 % I I _ MAN I I RC" TRAIL , X 000.00 Denotes existing. elevation - »r - - _ ( 000.00) Denotes proposed elevation I - Denotes drainage flow direction A Denotes spike ° 6. Construction Notes: Lowest allowable floor elevation : 880.5 1. Install rock construction entrance. House elevations (Proposed) / As-built 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. Lowest Floor Elevation :(881.2) / 4. Contractor must verify driveway design. Top Of Foundation Elev. :(889.2) 5. Contractor must verify service elevation prior to construction. (888.9) / 6. Add or remove foundation ledge as required. Garage Slab Elev. @ Door : T.O.F. Elevation @ Lookout (884.4) / General Notes: 1. Grading plan by Pioneer Engineering last dated 12/14/11 was used to determine proposed elevations shown herein. We hereby certify to Lennar Corporation that this survey, plan or 2. This survey does not purport to show improvements or report was prepared by me or under my direct supervision and encroachments, except as shown, as surveyed by me or under my that I am a duly licensed Land Surveyor under the laws of the direct supervision. State of Minnesota, dated 04/30/13. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. Signed: 17 Pioneer Engineering, P.A. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. BY: 5. This certificate does not purport to show easements other than Peter J. Hawkinson, Professional Land Surveyor those shown on the recorded plat. Minnesota License No. 42299 6. Bearings shown are based on an assumed datum. email-phawkinson@pioneereng.com Revisions: TAKE HOUSE Certificate of Survey for: P19NEERengineering l.)S-O1-13 S CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS Lennar Corporation Ph.: (651) 681-1914 16305 36th Ave N Ste #600 2422 Enterprise Drive Fax: (651) 681-9488 Plymouth, MN 55446-4270 Mendota Heights, MN 55120 www.pioneereng.com FolderProject#: # : 11 7386 2330012 Drawn by: Phone: (952) 249-3000 / Fax: (952) 404-1909 KKS n 7nnQ Pi-- P-i--ino Win New Construction Energy Code Compliance Certificate Per N 1 I U I.8 miming Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. Date Certificate Pasted Mailing Address (tithe Dwelling or Dwelling Unit 963 MONARCH TRAIL City EAGAN Sinclair Name or Residential Contractor MN License Number THERMAL ENVELOPE Type: Check All That Apply X Passive (No Fan) Total R -Value of all Types of Insulation Non or Not Applicable Fiberglass, Blown Fiberglass, Batts Foam, Closed Cell 'es c y T o Active (W th fan and monometer or other system monitoring device) r Insulation Location Foam Open Cell Mineral Fiberboar a- t o 7. en C2 e - ci so i2 Other Please Describe Here Below Entire Slab" .. X Foundation Wall 10 4NTERIOR Periinefci•. of Slab on Grade :' :: ' •°.:':::.:.::: : : .::;::: , [°: ":::`: :. .. Rim Joist (Foundation) 10 INTERIOR flintJoist(101Floor+).. .':'`:`: ::.;':".:'::';.:'::::"`.:':':"::.:::.::':" `.::' :: ' :: .°..:':'::' < i7::`.:- . ....... • .. Walt 21 lithr::..;:�:i":E�'ii`�:.:��':i::r.,:..:i::,::.':,::: :. ... :.: :�.:"�::.:: :�:., ,. Ceiling,fl.44 .. ::�,.: Ceiling, vaulted 44 Bay Windows•or eanHlevered arcus'::: :.' .'::<.:; ;'. , :. ;'. `''': ` ' ' '' 'ri; : ;::; : 38 :°::' `. 'r3.'. ;; ::::::;.'.. r5 Bonus room over garage X Describe other insolaEed areas::' Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U -Factor (excludes skylights and one door) U: 0.28 ./' Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.29 6.....' X R -value R-8 MECHANICAL SYSTEMS ( Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per inch. code Fuel Type:.:..::" :..:.:.::::.:.::::.. `:::, Natural Gas.;'.:::: Natural Gas ::: ;:. ,':::::_ Electrici?.::`;'::: Passive -,..._ Manufacturer Lennox AO Smith Lennox Powered Model.-Ir::ML193UH070XP36B' ": GPVH50N :.13ACX-030-230' Interlocked c rlo ked wit r exhaust device. Describe: Rating or Size Input in BTUS: 88 000 Capacity in Gallons: So Output in Tons: 3 Other, describe: lieatLoss: . ,.' ; .': ' "r.{6:' Heat Gain: ,: ; : - -- Location of duct or stem: y Structure's Calculated::. "'. .:.. ; ...::.: .. - • 20,641::.:_.. AFUE or EISPF% 93 < SEER: 13 Efficiency Calculated cooling load: Cfin's PLAN SINCLAIR " round duct OR Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): ydt required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Loca ion of duct or system: X Continuous exhausting fan(s) rated capacity in cfms: 2 continous fans on low TOTAL90CFMS ✓ Mechanical Room Location of fan(s), describe: Owners bath, Main Bath fifrrr's Capacity continuous ventilation rate in cfms: 90 6" d Insulated Flex Total ventilation (intermittent + continuous) rate in cfms: 465 " metal duct Created by BAM version 052009 City of EaRan Address: 963 Monarch Trail Zip: 55123 Permit #: 110778 The following items were / were not completed at the Final Inspection on: Final grade - 6" from siding Permanent steps -Garage Permanent steps — Main Entry Permanent Driveway Permanent Gas Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn Trail / Curb Damage Porch Lower Level Finish • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651)675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: G:\Building Inspections\FORMS\Checklists PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA119645 Date Issued:12/10/2013 Permit Category:ePermit Site Address: 963 Monarch Tr Lot:9 Block: 2 Addition: Stonehaven 4th PID:10-72703-02-090 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Softener Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Bob Sable 5242quebec Ave N. New Hope, MN 55428 Fee Summary:PL - Permit Fee (WS &/or WH)$55.00 0801.4087 Surcharge-Fixed $5.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Us Home Corporation 16305 36th Ave N Ste 600 Minneapolis MN 55446 Bob Sable Services 5242 Quebec Ave N New Hope MN 55428 (612) 534-6526 Applicant/Permitee: Signature Issued By: Signature