2013 RESIDENTIAL BUILDING PERMIT APPLICATION
71 1
3 Site Address: &V,~-Ve Unit
Date:
Name: Le v l v f V Phone: q52 -M^
Residen
nerd Address / City / Zip: ut5 Yv-Aw_. AL L 5u-i-k P`Y A. AN =52q6
Applicant is: Owner Contractor
t4y' uC Gt'a(A
Type of Work Description of work: Yom(- 62y
Construction Cost: Multi-Family Building: (Yes No )
Company: v v a r Contact:
Contractor I Address: 36 3U1* ' Av' :05~~e b City: RjV'u
i State: !vA YV Zip: ,1.. 1 111 Phone:
License Li ks Lead Certificate
If the project is exempt from lead certification, please explain why: (see Page 3 for additional information)
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
In the last 12 months, has the City of Eagan issued a permit for a similar plan based onn"a master plan?
_4Yes No If yes, date and address of master plan: 5q-7R ( y J°`vkP
Licensed Plumber: J " 1a~ I t Ca Phone: 9 52
Mechanical Contractor: ~j Phone: / c;t f
Sewer & Water Contractor: A r ya Phone: (O✓ 1 - 'r ~`l y" ~ 6t I
NOTE. Plans and supporting documents that you submit are considered to be public information. Portions of
the information may be classified as non-public if you provide specific reasons that would permit the City to
conclude that their are trade secrets.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours
before you intend to dig to receive locates of underground utilities. www.aonherstateonecall.or4
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days ofpermit issuance.
ris
x M l7l~ t QfV✓l CA VIA x
Applicant's Printed Name Applicant' ignature
Page 1 of 3
101 '5 CtdaK4►0VkZLO-IM
DO NOT WRITE BELOW THIS LINE I
SUB TYPES
Foundation _ Fireplace _ Porch (3-Season) _ Storm Damage
Single Family _ Garage _ Porch (4-Season) _ Exterior Alteration (Single Family)
Multi _ Deck _ Porch (Screen/Gazebo/Pergola) _ Exterior Alteration (Multi)
01 of I Plex _ Lower Level _ Pool _ Miscellaneous
Accessory Building
WORK TYPES
New _ Interior Improvement _ Siding _ Demolish Building"
_ Addition _ Move Building _ Reroof _ Demolish Interior
Alteration _ Fire Repair _ Windows _ Demolish Foundation
Replace _ Repair _ Egress Window _ Water Damage
Retaining Wall `Demolition of entire building - give PCA handout to applicant
DESCRIPTION
Valuation Occupancy MCES System
Plan Rev" w Code Edition 1007 SAC Units
(25%_ 100%Zoning City Water
Census Code Stories Booster Pump
# of Units / Square Feet 51 PRV
# of Buildings / Length 34 Fire Sprinklers
Type of Construction Width 3.L
REQUIRED INSPECTIONS
G Footings (New Building) Meter Size:
Footings (Deck) Final / C.O. Required
Footings (Addition) Final / No C.O. Required
Foundation HVAC _ Gas Service Test Gas Line Air Test
Drain Tile Other:
Roof: 'I' Ice & Water ,Final Pool: -Footings -Air/Gas Tests -Final
Framing G Siding: -Stucco Lath Stone Lath -Brick
Fireplace: ARough In u 7~ Air Test Final Windows
Insulation Retaining Wall: _ Footings _ Backfill _ Final
Sheathing Radon Control
Sheetrock Erosion Control
Reviewed By: , Building Inspector
RESIDENTIAL FE f ~r .0-AA, 77a4 7.7 ? / g
Base Fee It a
Surcharge
Plan Review
30"",# 3 *2 9
MCES SAC 71 16,
yB,~
City SAC WIT-
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Copies
TOTAL
Page 2 of 3
RITrE_ I V E D
New Construction Energy Code Compliance Certificate JUL 15 1013
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside Dale Certirieate Posted
the building. The certificate shall be completed by the builder and shall list information and values of
components listed in Table NI 101.8.
Mailing Address orate Duelling or Dwelling Unit City
3985 CEDAR GROVE LANE EAGAN
Name of Residential Contractor MN License Number
THERMAL ENVELOPE RADON SYSTEM
Type: Check All That Apply X Passive (No Fait)
o
d aCi
Active (IYctlt fan and rnonomeler or
F" othersystettl nogitoringdevice,);
~ E ~ 'o o u
w
Co U n v e
Q
RI G i
cz O y y 2 v
Insulation Location U a w y
a O m
c :n o a a ~ ~ .5 ~ '~c-o
21 Z w 'w w° w c2 a Other Please Describe Here
Below.Entire SIA X;
Foundation Wall 5.74ol Gr/t Gt- TJI~I u
Perimeter of Slab of Grade 10 itsreRloR
Rim Joist (Foundation) X
Rim Joist (1. Floor+) 10 INTERIOR
Wall 21
Geillit.g hat 44
Ceiling, vaulted
t3 Bay Windows or cantilevered areas
Bonus room over garage
Describe other insulated areas L / t~G t ` ART.Y:'.t11/ALL .R-11
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (exchides skylights and one door) U: 0.28 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.26 r-8 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type Natural.. Gas Electric Electric Passive
Manufacturer Lennox AO Smith Lennox Powered
Interlocked with exhaust device.
Model ML193UH045XP24B GPVH50N 13ACX-018-230 Describe:
Input in 44,000 Capacity in 5u Qutput in 5 Other, describe:
Rating or Size BTUS: Gallons: Tons:
'
I
Heat Coss: 36 921 Heat Gain: 4 1 Location of duct or system:
Structure's Calculated
AFUE or SEER: 13
HSPF%
93
i Calculated
Efficiency 16,897
coolieg load: Chas
PLAN CMS Jefferson „ round duct OR
Mechanical Ventilation System " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): X Not required per mech. code
Select Type Passive
Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Location orduct or system;
X Continuous exhausting fan(s) rated capacity in cfms: I fan continous low 50efm Mechanical Room
Location of fan(s), describe: Owners bath, Main Bath Cfln's
Capacity continuous ventilation rate in cfins 50 Insulated Flex
Total ventilation (intermittent + continuous) rate in cfins: i 85 " metal duct
Created by BAM version 052009
Ventilation, Makeup and Combustion Air Calculations
Submittal Form For New Dwellings
These blani( submittal forms and instructions are available at the City website and at City Hall. The completed form must be submit-
ted in duplicate at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at:
Site address G~ e^ r1
' Grc. FCI VIP Date
FE
Contractor _ /J/~/jy j7 Completed
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including
Basement - finished or unfinished) Total required ventilation loo
Number of bedrooms Continuous ventilation
Directions' Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1.
The table and equation are below.
Table N1104.2
Total and Continuous Veritilation Rates (in cfm)
Number of Bedrooms
1. 2 3 4 5 6
Conditioned space (in Total/ Total/ Total/ Total/ Total/ Total/
sq:;ft.) continuous continuous continuous continuous continuous continuous
1000-1500 60%40 75/40 90/45. 105/53 120/60 135/68
1501-2000 70/40. 85/43, 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110 125/63 14U/70 155/78
2501-3000 90/45 105/53. 120/60: 135/6$;. 150/75 165/83
3001-3500 100/50 115/58 130/65 145/73 160/80 175/88.
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 .165/83 180/90 195/58:
4501-5000 130/65. 145/73 160/80 175/88 190/95 205/103.
5001-5500 14o/n 155/78 170/85 185/93 200/100 215/108
5501-6000 150/75 165/83 180/90 195/98 210/105 225/113
Equation 11-1
(0.02 x square feet of conditioned space) + [15 x (number of bedrooms + 1)] = Total ventilation rate (cfm)
Total ventilation -The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,
for each one-hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventila-
tors (ERV) the average hourly ventilation capacity must be determined in consideration ofpny reduction of exhaust or out outdoor
air intake, or both, for defrost or other equipment cycling.
Continuous ventilation -A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm. shall be provided, on.a con- _
tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may
have automatic cycling controls providing the average flow rate for each houris met.
G:ISAFETYUMVent-makeup-comb air submittal (2).docx Page 1 of 6
Section B
Ventilation Method
(Choose either balanced or exhaust only)
Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recov- ® Exhaust only
ery Ventilator) - cfm of unit in low must not exceed continuous venti- Continuous fan rating in cfm
lation rating by more than 100%,
Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating by more than 100%)
Directions - Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV's.
Enter the low and high cfm amounts. Low c fm airflow must be equal to or greater than the required continuous ventilation rate and
less than 100% greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.)
Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Section C
Ventilation Fan Schedule
Description Location 1 Continuous intermittent
66
Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous
or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low m air rating
and less. than 100% greater than the continuous rate. (For instance, If the low cfm is 40 cfm, the continuous ventilation fan must not
exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Section D
Ventilation Controls
(Describe operation and control of the continuous and Intermittent ventilation)
I
cr r.rP
Directions -Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and inspectors to verify design and
installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If
exhaust fans are used for building ventilation, describe the operation and location of any controls, indicators and legends. if an ERV or HRV is to be
installed, describe how it will be installed. if it will be connected and Interfaced with the air handling equipment please describe such connections as
detailed in the manufactures' instaliation instructions. If the installation instructions require or recommend the equipment to be interlocked with the
air handling equipment for proper operation, such interconnection shall be made and described.
Section E
Make-up air
Passive (determined from calculations from Table 5013.1)
4 4
Powered (determined from calculations from Table 501.11)
Interlocked with exhaust device (determined from calculation from Table 501.3.1)
Other, describe:
Location of duct or system ventilation make-up air: Determined from make-up air opening table
Cfm Size and type (round, rectangular, flex or rigid)
(NR means not required)
Page 2 of 6
Directions - In order to determine the makeup air, Table 501.3.1 must be filled out (see below). For most new installations, column A
will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column.
For existing dwellings, see IMC501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re-
quired far ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type
(round, rectangular, flex or rigid) to the last line of section D. The make-up air supply must be Installed per IMC 501.3.2.3.
Table 501.3.1
PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS
(Additional combustion air will be required for combustion appliances, see KAIR method for calculations)
One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical-
vent or direct vent ap- assisted appliances and gas or oil appliance or ly vented gas or oil
pliances or no combus. power vent or direct vent one solid fuel appliance appliances or solid fuel
tion appliances appliances appliances
Column C Column 0
Column A Column B
1.
a) pressure factor 0.15 0.09 0.06 0.03
(cfm/sf)
b) conditioned floor area (sf) (including `
unfinished basements)'.
Estimated House infiltration (cfm): [ta
x 1b]
2; Exhaust Capacity .
a) continuous exhaust-only ventilation
system (cfm);, (not applicable to ba-
lanced ventilation systems such as
HRV) -
b) ciothes.dryer (cfm). 135 135 135 135
c) 80% of largest exhaust rating (cfm);
Kitchen hood fr recir
(not;appLcabla if recirculating system
or if powered makeup air is electrically
interlocked and match to exhaust)
d) 80% of next largest exhaust rating
(cfm)bath fan tyPically Not
(not applicable if recimuiating system Applicable
or if powered makeup air is electrically interlocked and matched to exhaust)
Total Exhaust Capacity (cfm); / Ps
[2a+.2b:+2c+2d] . 4
3. Makeup Air Quantity (cfm)
aj total exhaust capacity (from above)
b) estimated house infiltration (from
above
Makeup Air Quantity (cfm);
(3a - 3b]
if value I
( Is negative, no makeup air is v
needed)
4. For makeup Air Opening Sizing, refer
to Table 501.4.2 IVA V/
A. Use this column If there are other than fan-assisted or atmospherically vented gas or oil appliance or If there are no combustion appliances. (Power vent
and direct vent appliances maybe used,)
a.- Use this column if there is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be In-
cluded.)
C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance.
0. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or all
appliances and solid fuel appliances.
Page 3 of 6
Makeup Air opening Table for New and Existing Dwelling
Table 501.32
One or multiple power One or multiple fan- One atmospherically Multiple atmospherically
vent, direct vent ap- assisted appliances and vented gas or oil ap- vented gas or all ap- Duct di-
pliances, or no combus- power vent or direct pliance or one solid fuel pliances or solid fuel ameter
tion appliances vent appliances appliance appliances
Column A Column B Column C Column D
Passive opening 1-36 1-22 1-15 1-9 3
Passive opening 37-66 23-41 16-28 10-17 4
Passive opening 67-109 42-66 29-46 18-28 5
Passive opening 110-163 67-100 47-69 29-42 6
Passive opening 164 -232 101-143 70 - 99 43 - 61 7
Passive opening 233-317 144-195 100-135 62-83 8
Passive opening 318 - 419 196 - 258 136- 179 84-110 9
w/motorized damper
Passive opening 420-539 259-332 180-230 111-142 10
w/motorized damper
Passive opening 540-679 333 -419 231- 290 143 -179 11
w/motorized damper
Powered makeup air >679 >419 >290 >179 NA
Notes:
A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to
determine the remaining length of straight duct allowable.
B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted.
C. Barometric dampers are prohibited In passive makeup air openings when any atmospherically vented appliance is installed.
0. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Sections F
Combustion air
Not required per mechanical code (No atmospheric or power vented appllances) 2 L u/4Tllil7 ~~/LA % 17i,L
Passive (see IFGC Appendix E, Worksheet E-1) Size and type
Other, describe:
Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented
or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combus-
tion air vent supplies must communicate with the appliance or appliances that require the combustion air.
Section F calculations follow on the next 2 pages.
i
Page 4 of 6
0
M s
;;co ~ N i ~ ff1
1 II
i W
N
V _
L
.Z p N O y Cy r
co asn ' O
' L] L _
LO to 0 0 75
x; m a. m u a x m z o m° W
o f w: <C M U a a~ o a~ n
CD CL y N Z M W W 1- F- W
m ar aD
J Y (7 2 m In
c
U i ~ S
d ~ cn
uw O
CD 0
to co QD
O N U ~
Z m °w to X ~ (00 v N n;
U X X X X X X
LL w
LLI C-4 -It V) t- f- V r
r
Q U' p W W W W w W W W W
1XZ Z z z z z z z z Z
C) z ix :iii
0 0 Q ;m Z z z Z Z Z Z Z Z
CL Cl co 0
NM a W
L i11 U Q iQ
LL
Q~ N LL ~ U Ir m Q
z u M W uVi u~i N w
® v d N N N y
U) T
co Q Ft C.): V) Cq :1 :r m m a-
v v
N C N. S N N {/j fn N N ~W
.C 6S ` N N ~ N H tt) N' U
co O. U- a. w I ui u~ a o vi ni ui' U
C .C `N' F' F U U F
U) fq fq t 3 U N N Iq
M M
C) C; 0
N p N.
F- u3 W Z Z tFi U'
V ~
Q W Q Q kV- Q U
x z z m
H p5 I~ ¢ ` F F -J. Q ¢ -J a
W w rO _3 z z z z z Z z! z
zz < f-J z T z 2 Z zz 6
z LLI
,
W C6 Q M X (7 C7 C7 ( C7 F W C)
Cam-'' Q J I V ; LL. CO to (n m co = IL fZ'.
m a ~z
i Qrop
Z LO
z C) ^L 0 Z< N N N N N N N N
z c7 Z cn ' o= Z = 2 p Z' S
W tD -1 11 w d N 0 0 0 U) 0 0 N to U)
_Jr0-
J
o
I 'rzi m-t~ L -
j Q LL. N N N r I
C N N 00
G RS (A ~ 3 a d O ~ p O O O O I
ar
. : M L d V O CO lA M t['D R. rfI 8 N CO
CL a
010 !J N N M M M M M c3 N NN
t> d C f1 co
RECEIVED
JUL 15 2013
Project Summar Job: Colonial Patriot Jeffers...
Wrlg~'it50~~' y
Enure House Date: July 95, 2093
By:
Elander Mechanical Inc.
591 Citation Drive, Shakopee, MN 55379 Phone: 952-445.4692 Fax: 952-445-7487
0 0 0
For: 3 g8s' C-; JC.✓ ~rG3 VP C ~ ^
Notes:
U- a s s
Weather: Minneapolis-St. Paul, MN, US
Winter Design Conditions Summer Design Conditions
Outside db -15 °F✓- Outside db 88 OF
Inside db 70 OF Inside db 72 OF
Design TD 85 OF Design TD 16 OF
Daily range M
Relative humidity 50 %
Moisture difference 33 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29434 Btuh Structure 12300 Btuh
Ducts 1216 Btuh Ducts 642 Btuh
Central vent (69 cfm) 6272 Btuh Central vent (69 cfm) 1173 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping uh
Equipment load 36921 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 14115 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 1 (Tight) Structure 1173 Btuh
Ducts 117 Btuh
Heating coolin Central vent (69 cfm) 1492 Stuh
Area (ft2) 1852 1852 Equipment latent load 2782 Btuh
Volume (ft3) 14816 14816
Air changes/hour 0.14 0.07 Equipment total load 6897 Btuh
Equiv. AVF (cfm) 35 17 Req. total capacity at 0.70 SHR on
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade MERIT 90 Trade 13ACX Series - RFC
Model ML193UH045XP24B-* Cond 13ACX-018-230-*
AHRI ref 4792130 Coil C33-25*+TDR
AHRI ref 1031313
Efficiency 93AFUE Efficiency 11.9 EER, 13.5 SEER
Heating input 44000 MBtuh Sensible cooling 12950 Btuh
Heating output 41000 Btuh Latent cooling 5550 Btuh
Temperature rise 50 OF Total cooling 18500 Btuh
Actual air flow 768 cfm Actual air flow 617 cfm
Air flow factor 0.025 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wreghtsoft° Right-Suitee Universal 2012 12.1.06 RSU13410 2013-Jul-15 15:15:11
-rr Page 1
ACCK ...Heat Losses 20131Lennar Patriot Jefferson A.rup Calc = MJ8 Front Door faces: N
RECEIVED
JUL 15 2013 Job: Colonial Patriot Jeffers...
wrightsoft' Component Constructions Date: July 15, 2013
Entire House By:
Elander Mechanical Inc,
591 Citation Drive, Shakopee, MN 55379 Phone: 952-445-4692 Fax: 952-445-7487
0 0 0
For:
1- 0 0 0 0
Location: Indoor: Heating Cooling
Minneapolis-St. Paul, MN, US Indoor temperature (°F) 70 72
Elevation: 837 ft Design TD (°F) 85 16
Latitude: 45°N Relative humidity 50 50
Outdoor: Heating Cooling/ Moisture difference (gr/lb) 54.5 32.7
Dry bulb (°F) -95 88 Infiltration:
Daily range (°F) - 19 ( M } Method Simplified
Wet bulb (°F) - 71 Construction quality Ti ht
Wind speed (mph) 15.0 7.5 Fireplaces 1 Right)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft= Stuh/n'-T ft? Tithuh BluhAll Ruh BtuhAN DO
Walls
12B-Osw: Frm wall, vnl ext r-11 q~av ins, 1/2" gypsum board int n 416 0.097 11.0 8.24 3430 2.47 1027
fnsh, 2"x4" wood frm
12F-Osw: Frm wall, vni e r 21 av ins, 1/2" gypsum board int n 139 0.065 21.0 5.52 768 1.08 150
fnsh, 2"x6" wood frm a 398 0.065 21.0 5.52 2197 1.08 430
s 513 0.065 21.0 5.53 2833 1.08 555
w 432 0.065 21.0 5.52 2386 1.08 467
all 1481 0.065 21.0 5.52 8184 1.08 1603
Partitions
(none)
Windows
61A: VINYL Insulated Glass Double Hung; NFRC rated a 77 0.280 0 23.8 1841 28.7 2220
SH(_ GC=0.26) s 42 0.280 0 23.8 1004 16.5 697
w 64 0.280 0 23.8 1527 28.7 1842
all 184 80 0 23.8 4371 25.9 4759
Doors
11JO: Door, mtl fbrgl type n 21 0.600 6.3 51.0 1071 16.7 351
e 21 0.600 63 51.0 1071 16.7 351
s 21 0.600 6.3 51.0 1071 16.7 351
all 63 0.600 6.3 51.0 3213 16.7 1053
Ceilings
16CR-44ad: Attic ceiling, asphalt shingles roof m 0.r-44 eil ins, 1116 0.022 44.0 1.87 2087 0.91 1015
5/8" gypsum board int fnsh
Floors
20P-38c: Fir floor, frm fir, 12" thkns, carpet flr fn r-5 ext ins, r-38 250 0.030 38.0 2.55 638 0.34 85
cav ins, gar ovr
20P-38v: FIr floor, frm fir, 12" thkns, vinyl fir fnsh, r-5 ext ins, r-3$ 130 0.030 38.0 2.55 332 0.34 44
cav ins, gar ovr
Ctpm: Bg floor, heavy dry or light damp soil, on grade depth, 134 0.355 10.0 30.2 4043 0 0
r=10 a ge ins
Wrightsoft° Right-Suite® Universal 2012 12.1.06 RSU13414 2013-Jul-15 15:15:11
Page 1
ACCK ...Heat Losses 20131Lennar Patriot Jefferson A.rup Cale = MJ8 Front Door faces: N
MULTI-FAMILY
PLAN REVIEW FOR COMPLIANCE WITH AIRCRAFT NOISE ORDINANCE
Compliance with Procedures to Ensure
Submitter: Noise Impact Area Adequate Noise Attenuation:
Lennar Airport - MSP International Exterior wall construction:
16305 36th Ave. No. Noise Zone - 4 Vinyl
Suite 600 15/32" sheathing
Plymouth, MN 55446 New Infill Residence is a "COND" Tyvek wrap
952-249-3000 use in Noise Zone 4 2x6 studs 16" O.C.
R-21 batt insulation with 1/2" gypsum board
Roof Construction:
Plan. Reviewed: _ Peaked roof with manufactured trusses 24" O.C.
'2'Q SS Roof vents
Gllz U t, N Shingles
Information Submitted: 15# felt
Annotated architectural drawings includin : 1/2" sheathing
Blown insulation R-44
Windows: Atrium 5/8" gypsum board
Swinging Patio Doors: Atrium
Entry Doors: Therma Tru Mechanical Ventilation System:
Skylights: N/A 2-ton central air conditioning unit
Compliance with STC Requirements: Window, Door Frame, Perimeter and Other Seals:
All window and door openings are to be caulked
Average window/wall area for exterior wall: p® with butyl-based caulk
With this window/wall area ratio and STC 40 walls, windows Fireplace Chimney Cap:
with an STC 30 can be used to meet the noise reduction N/A
requirements;
Ventilation Duct Exterior Wall Penetrations:
Summary: All exterior ducts will have bends as required
by the ordinance
Other measures including duct bends and caulking are being
taken to ensure minimum transmission of noise through the Door and Window Construction:
exterior building shell so that the construction should meet Windows: Atrium (30 STC)
the compatibility guidelines.
Sliding Patio Doors: Atrium (30 STC)
Therefore, the materials and construction as proposed should
meet the requirements of the Eagan aircraft noise ordinance. Entry Doors: Therma Tru (29 STC)
Skylights: N/A
Review Completed (date):
Other Exterior Wall Penetrations:
Review Completed b : Tom Tamte Sill sealer between plates and blocks
f
Jeffrey Wheeler
From: Tom Tamte [Tom.Tamte@lennar.com] R E r f= i v
Sent: Monday, July 08, 2013 10:39 AM
To: Jeffrey Wheeler JUL 0 8 2013
Cc: Matthew Remund; Mike Lind
Subject: Re: 3983 & 3985 Cedar Grove Lane, permit application
Follow Up Flag: Follow up
Flag Status: Flagged
Mr. Wheeler:
Received your email and am working thru plan corrections and updates asap.
From what I have been informed, we changed from 2x6 party walls to 2x4 party walls on the last few buildings. I sent an
email to Nick Hanson Group to prepare a letter for this change.
r
Based on your email below, I will address issues.
1. Will run another 2 sets of plans for this address, but have to ask, if we have another 5 or 6 unit building coming up, are
you still going to require 2 sets per unit. So, that would mean we need to print 10 to 12 full sets, just for permit review?OA, Aaf
2. We will not be adding "sprinkler system" in this 2 unit building. /?9-jvw T A
3. Will do a better job of listing all headers on the Architectural sheets, although, only ones not called out would be the 2-
2x10 headers. ~ ~^p r A WYH` 191,r,
4. Will work with building partners to update R-val a~ cviLG,~aT'
5. Question why a roof truss layout is require . All tru o front to back. There is an oversized gable on front, but this
is overframed on roof deck to allow for proper en ing of roof area.
6. 1 have never heard of Radon piping around the perimeter of garage area. If you could let me know where this
requirement is located in the code book, will review and respond accordingly.
thank you
LENNA
Tom Tamte
Product Development Mgr
Lennar Minnesota
tom.tamte@ len nar.com
www.lennar.com
Office Phone: 952-249-3001
Cell Phone: 612-250-4021
16305 36th Avenue N, Ste 600
Plymouth, MN 55446-4270
From: Jeffrey Wheeler <JWheeler(a.citvofeagan.com>
To: Matthew Remund <Matthew.Remund(a)Lennar.com>
Cc: 'Tom Tamte' <Tom.Tamtena.lennar.com>
Date: 07/05/2013 09:25 AM
Subject: 3983 & 3985 Cedar Grove Lane, permit application
1
Hi Matt:
I am reviewing plans for 3983 & 3985 Cedar Grove Lane.
These are on separate lots with a property line in between. So I ne d 2 s=foreach pplication.
The total building square footage (4608 sq ft) is less than the threshold to require sprinklers (9250 sq ft Do you intend to install
sprinklers anyway? AI1.1
Please provide headers sizes for all openings in the bearing walls PA6, ~ X 1~
Please provide a roof framing layout for the 3983 (not marked on the plan) N'&* T
The R-values on the cross section page of the plans do not match the heat loss calcs ✓
R-38 in the ceiling? 2
R-19 in the walls?
The foundation around the perimeter of the tuck under garage creates a separate radon area provide a detail for venting the under
slab space separately or combined -1: ,h/j &a
Corrections for the energy code compliance certificate
Remove R-38 at the cantilever
There are no cantilevers
Remove R-21 batts & R-10 closed cell foam at the bonus room (over garage)
Floor insulation only
Correct R-6 sheathing at the bonus room
R-5 per the plan and heat loss calcs
Correct 130CFM continuous at ventilation
50 CFM per the ventilation submittal
Thanks,
Jeff Wheeler
Hope you are having a pleasant holiday week end
41`
Jeffrey T Wheeler I Building Inspector City of Eagan City of ap
City Hall 13830 Pilot Knob Road I Eagan, MN 55122 651-675-56801651-675-5694 (Fax) I Iwheeler(c~citvofeaaan.com
THIS COMMUNICATION MAY CONTAIN CONFIDENTIAL AND/OR OTHERWISE PROPRIETARY MATERIAL and is thus for use only by the intended recipient.
If you received this in error, please contact the sender and delete the a-mail and its attachments from all computers.
2
Jeffrey Wheeler
From: Tom Tamte [Tom.Tamte@lennar.com]
Sent: Tuesday, July 09, 2013 1:40 PM
To: Jeffrey Wheeler
Cc: Matthew Remund; Mike Lind; 'Rodney Chwialkowski'
Subject: RE: 3983 & 3985 Cedar Grove Lane, permit application
Thank you Jeff for your reply.
Since this is the last building for Nichola's Ridge, am hoping we can handle this with email clarification to all.
Please assume, all headers not called o 'will be (2) 2x10~~
We will be using R-44 for ceilings, R-1 for party walls, and R-21 for exterior walls. Will pass this info on to our
mechanical partner to match their reports with this info.
Upon further review of our submitted plans, we do not show truss direction on Jefferson "B" elevation second floor an
These trusses will follow similar to the Jefferson "A", running front to back. Will update base plan for future.
We will be updating our base plans to show 2x4 framing at party walls, for all future submittals. Will follow up with the`+
letter from Hanson Group Engineering.
Please let me know if you need any thing else to keep this one moving. Thank you for your help with this project
1
MEMORANDUM
I hereby certify that this plan, specification or report
To: Lennar Corporation was prepared by me or under my direct supervision
Re: Interior Common Wall Framing and that I am a duly licensed professional engineer
N icols Ridge under the laws of the St a of nnesota.
Colonial Patriot-2 Unit
3985-3983 Cedar Grove Lane Nick Hanson
Eagan, MN Date: 7-8-13
Project No. 3.117 Minnesota Registration No. 46665
The purpose of this memorandum is to report the findings of a limited scope structural engineering review
of a proposed shared common wall framing member sizes in the Nicols Ridge Development at the address
above. The Hanson Group has reviewed the proposed drawings and the following is noted:
1. Drawings provided by Lennar 06-11-13 dated show that the 2-unit configuration is comprised of the
Jefferson "A" and Jefferson "B" units.
2. According to the drawings the upper floor trusses span left to right with an interior bearing wall at
the shared garage-house wall and an interior beam line dividing the Great Room and the Dining
Room. The roof trusses span front to back with no interior bearing points and no bearing at the
shared-common wall between the units. The main floor structure is a concrete slab-on-grade floor.
3. The shared common wood framing walls are to be 2x4 studs at 16" maximum on-center spacing
bearing on the foundation wall between. The studs are to be Spuce-Pine-Fir stud grade or better for
the 8'-11/8" framing walls with a double 2x4 top plate fastened together at splice points and
corners in accordance with the Code. All sheathing and attachment of the materials is to be in
accordance with the Code. All inspections are reportedly being conducted by City officials.
After our review of the above information and associated documentation, it is our professional
engineering opinion that the proposed construction and wood framing members of 2x4 sawn studs at
16" maximum on-center spacing will be structurally acceptable.
This document applies to the limited scope partial review of the proposed shared common wall framing
member sizes only. All other aspects of the project are outside the scope of this document and no other
conditions, areas, or further engineering within the models were requested or reviewed. No site visit was
conducted or requested. The Builder shall verify that the provided drawings reflect the existing conditions.
All construction is to be in accordance with this document, standard industry practice, and the
requirements of the Code.
Sincerely,
The Hanson Group
Jeffrey Wheeler JUL 16 2W
From: Tom Tamte [Tom.Tamte@lennar.com]
Sent: Tuesday, July 16, 2013 11:45 AM
To: Jeffrey Wheeler
Cc: Matthew Remund
Subject: Fw: 3983 & 3985 Cedar Grove Ln
Attachments: GARAGE DOOR HDR_7-16-2013.pdf
Follow Up Flag: Follow up
Flag Status: Flagged
Jeff:
Below is a calc on the garage door headers, per your request, from the engineer of record, Wenzel Engineering.
Per their comments, looks like we will bump the header size up to 14" depth for the Stonehaven CMS plans. Will be
submitting permit plans for the first (2)
buildings in the next week or so.
Just to confirm, we would like to Master Permit these, how many sets will you require for Master Review.
thank you, and please call or email with any questions.
LEN1"' A
Tom Tamte
Product Development Mgr
Lennar Minnesota
tom.tamteCcblennar.com
www.lennar.com
Office Phone: 952-249-3001
Cell Phone: 612-250-4021
16305 36th Avenue N, Ste 600
Plymouth, MN 55446-4270
Forwarded by Tom Tamte/wAYZATA/CENT/Lennar on 07/16/2013 11:40 AM
From: "Patty Cole" <pcole (a)wenzelengineering.com>
To: "Tom Tamte" <Tom.Tamtefd)lennar.com>
Date: 07/16/2013 10:31 AM
Subject: Re: 3983 & 3985 Cedar Grove Ln
Tom,
Upon looking into this, I realized that we only did braced wall engineering for these buildings. I-level or your lumber
supplier did the header design. That being said, we do show the header size of 3-11 7/8" LVL's on the drawing as part of
the Portal Frame over the garage door. The American Plywood Association has the standard detail that we use, that
shows a minimum of 3 1/2" wide X 11 1/2" deep header for the frame. We did not re-check the header sizes for the OH
door.
I AM able to get it to work and it meets code, but the deflection is slightly higher than I (and Lennar) normally prefer. I
would normally limit the Live Load (i.e. snow) deflection to L/360 (0.52" in this case). Code requires that we limit this
1
4-
0-
O
O
r a
I I` o
CV 0 r
oM
+ q o
(L N
N ~
CD
cY)
1-1
X
Q
LO
LO
I~ Y
o UI O O O
m
} c c
Q
2 "
O co
cz Lr) O N LO co M O
L CO ~ r- ~ O M N
N O O N co It 00
N cz p Ix O II II
ON 0) J RS ° V' 4 II II
CL J N
J J -J J >
~ a J
00 Q Q Q Q m
T ) 4-
Y
O
.cn C) O Ott N
E N T CD O N r 11
0 W OU-) c q CD 00 C) M
CO co N O N O_
J N M
a> M ado
> r
0 T co
L T
II II
_0
d
z
>p 11
_0 LL 0
tZ fz
cl) cN N
C >
C c0
Ln ~ M N LO 0 0 0
C,) t-~ 00 T U) O O O O
~ r T ~ O r r r T
N N
C0 U
CO
LL
0 cz cz
mm 0 J 0 LL >
U U U Y X
u
0
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
PROPERTY LEGAL: -6 0
DATE OF SURVEY: LATEST REVISION:
m
a~
c
ca
U
O z a DOCUMENT STANDARDS
-R/ ❑ ❑ • Registered Land Surveyor signature and company
❑ ❑ • Building Permit Applicant
..2- ❑ 0 • Legal description
0 ❑ • Address
pf ❑ ❑ • North arrow and scale
❑ ❑ • House type (rambler, walkout, split w/o, split entry, lookout, etc.)
❑ 0 • Directional drainage arrows with slope/gradient %
0 0 • Proposed/existing sewer and water services & invert elevation
0 D • Street name
❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.)
❑ ,PJ ❑ • Lot Square Footage
❑ 0 • Lot Coverage
ELEVATIONS
Existin
D e1 D • Property corners
❑ 0 • Top of curb at the driveway and property line extensions
❑ D • Elevations of any existing adjacent homes
❑ 0 • Adequate footing depth of structures due to adjacent utility trenches
❑ X ❑ . Waterways (pond, stream, etc.)
Proposed
0 D • Garage floor
❑ f.Y D • Basement floor
❑ ❑ • Lowest exposed elevation (walkout/window)
❑ ,P1 ❑ • Property corners
e'z 0 0 • Front and rear of home at the foundation
PONDING AREA (if applicable)
❑ 0 • Easement line
0 0 • NWL
❑ 0 • HWL
❑ ❑ • Pond # designation
0 D • Emergency Overflow Elevation
0 0 • Pond/Wetland buffer delineation
Y Shoreland Zoning Overlay District
Y • Conservation Easements
DIMENSIONS
❑ ❑ • Lot lines/Bearings & dimensions
❑ ❑ • Right-of-way and street width (to back of curb)
❑ 0 • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
❑ ❑ • Show all easements of record and any City utilities within those easements
A 0 ❑ • Setbacks of proposed structure and si setback of adjacent existing structures
,I' D 0 • Retaining wall requirements:
Reviewed By: /.:fl Date
GJFORMS/Building Permit Application Rev. 11-26-04
Surveyor s Certificate ll
SURVEY FOR : Lennar
DESCRIBED AS :Lots 1-2, Block 1, NICOLS RIDGE 5TH, City of Eagan, Dakota County,
Minnesota and reserving easements of record.
Maximum slide
0 retaining Wail W
Be Required
`t
t
8 8 IL 824.3
Future 0
Townhome
r^'r O ~ 'O dpi
0 826. O 5.0
O
824.3
CB 'h~ $p°I
r, 822. p 827.0
0 O 5.7
-
CIO
r 825.8 ~~06~"7°~~ 09@ c~2°~° Oi9
rr - 826.8 `.?0 °1 ' j 0-
0 827.0
.o' O C
° o
2 0 0
\ ~O 826. 'rn `ocp 9° r'
O p rnasf; 86.9
0P" 825.6 60~0 I'd ~ 827.1 10
0
All;
? o
INSTALL O ~ 00 oW ~6~~ BM:7 261E
'PERIMETER CONTROL 826.8 827.9
p0 '
13 lb
Y 0O o4j~
\ \ 0.7 9.3
O
I
1 I
I I
\ I i
Existing 11
I Townhome
\ i TOB=831.9
\ 1 I
I 1
I
\ ~ I
I
R .EYED _ EA _ A N
EAGAN irNG G 6hPT.
711Y ~
PROPOSED ELEVATIONS BENCHMARK,
Top of Foundation = 827.5
Garage Floor = 827.1
Basement Floor = n/a
Aprox. Sewer Service = Verify
Proposed Elev. = MIN. SETBACK REQUIREMENTS
Existing Elev. _
Drainage Directions = Front - House Side -
Denotes Offset Stake = • Rear - Garage Side -
SCALE: 1 inch = 30 feet
JOB NO:
I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTATION 13R-048
HEDLUND OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED
BY ME OR UNDER MY DIRECT SUPERVISION AND DOES NOT PURPORT TO BOOK: PAGE:
PLANNING ENGINEERING SURVEYING SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS HOWN.
2005 Pin Oak Drive
Eagan, MN 55122 DATE 3 / 25~ 13 ~ • CAD FILE:
Phone: (651) 405-6600 DATE 6 1 13 R D. LINDGREN, LAND VEYOR Nicols Ridge 4th
Fax: (651) 405-6606 0 J NESOTA LICENSE NUMBER 4376
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA119720
Date Issued:12/16/2013
Permit Category:ePermit
Site Address: 3985 Cedar Grove Lane
Lot:1 Block: 1 Addition: Nicols Ridge 5th
PID:10-50904-01-010
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Water Softener
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Charles Sundean
8201 Old Central Ave
Spring Lake Park, MN 55432
Fee Summary:PL - Permit Fee (WS &/or WH)$55.00 0801.4087
Surcharge-Fixed $5.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Us Home Corp
16305 36th Ave N
Minneapolis MN 55446
Water Doctors Water Treatment Company
8201 Old Central Ave, Suite F & G
Spring Lake Park MN 55432
(763) 535-1800
Applicant/Permitee: Signature Issued By: Signature
411
City of Eapn
Address: 3985 Cedar Grove Lane Zip: 55122
The following items were / were not completed at the Final Inspection on:
Permit #: 111941
Final grade - 6" from siding
Permanent steps — Garage
Permanent steps — Main Entry
Permanent Driveway
Permanent Gas
x
x
X
Retaining Wall or 3:1 Max Slope
Sod / Seeded Lawn
Trail / Curb Damage
tviolvf,
Porch
Lower Level Finish
Deck
Fireplace
Nzw6-
Ivo1VIZi
• Verify with your builder that roof test caps from the plumbing system have been removed.
• Turn off water supply to the outside lawn faucets before freeze potential exists.
• Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an
irrigation system.
Building Inspector:
G:\Building Inspections\FORMS\Checklists