2149 Cedar Grove Tr - Heat Calcs New Construction Energy Code Compliance Certificate Per N1101.8 Building Ceuilicate. A building certificate shall be posted ht a permanently visible location inside Dato Ce+tificataPosted the building, The certificate shall be completed by the builder and shall list information and values of eotn nentslistedinTabieNl]01.8, Place your Mailiag Addressethe able p 1 1.8. MODEL 430 Bl! logo here fume of Rtadenliat C`onfrtNer MN Lkca umber LENNAR HOMES Community Ptan rD HERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply x Passive (No Tarr ) U e°, a o '3 ,c 'g Insulation Location c 7 a b z w w w° w i~ t Other Please Describe Here Foundation Wall NA Inn .3 Rim Joist (Found atioa N Type fn ocation: hauler exterior or iNegrat Wall NOWN INS 21~ Cellin , vaulted y. , ¢NA° Bonus room over ara a 38 21 10 6 Windows S Doors eating or Coolie Ducts outside Conditioned Spaces Average U-Factor (excludes skylights and one door) Cl; 0.29 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): .26-.30 R-value MECHANICAL SYSTEMS Makeup Air Selecl a Type Appliances Heating System Domestic Water Heater Cooling System x Not required per mech. code Passive Manufacturer LENNOX A.O. SMITH LENNOX Powered Interlocked with exhaust device. Describe: Input in 45,000 Capacity in w Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Location of duct or system: AFUE or 92 SEER: E3 HSPI~% F,fficienc l;alcuiatcd } g 000 coolie load: CfiWs " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type urce heat pump with gas back-up furnace): x Not required per mech. e Select 7YPe Passive Heat Recover Venlilator(HRV) Capacity in cfms: Low: high: Other, describe: Baer Recover Ventilator (ERV) Ca cif in cfms: Low; Hi : Location ofduct or system: X Continuous exhausting fart(s) rated capacity in cfms: 90 furnace room Location of fan(s), describe: MAINfMAS'rER BATH Cftn"s Capacity continuous ventilation rate in cfms: 80 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 210 " metal duct Lennar --430-8 Franklin Hayfield Windows HVAC Load Calculations for.... . Lennar Homes Prepared By: Sabre Plumbing And Heating Saturday, August 11, 2012 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. NUNN- v Project Title: Lennar-430-8 Franklin -Hayfield Windows Project Date: 8/10/2012 Client Name: Lennar Homes Company Name: Sabre Plumbing And Heating Reference City: Minneapolis, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains PA Bulb Wet Bulb Rel.Hum Rel.Hum Der Bulb Difference Winter: -11 -12.38 32% n/a 72 n/a Summer: 88 73 50% 50% 75 35 Total Building SupplX CFM: 486 CFM PeC-$gure ft.: 0.269- Square ft. of Room Area: 1,808 Square ft. Per Ton: 2,100 Volume (ft') of Cond. Space: 14,464 Total Heating Required Including Ventilation Air: 43,114 Btuh 43.114 MBH Total Sensible Gain: 8,146 Btuh 79 % Total Latent Gain: 2,187 Btuh 21 % Total Cooling Required Including Ventilation Air: 10,333 Btuh 0.86 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Ci:\rhvac oroiectsiLENNAR - Q';n_R Franklin- C+nun rho Scope Not tt.- Son at Net Sen Sys Sys Sys Ton lion Area Gain Gain Gale Loss CFQ GC19 Act Duct BuUdhg 0.8fi 2,100 1,808 8,146 2,187 10,333 43,114( 466 332 486 _ Size System 1 0.86 2,100 1,808 8,146 2,187 10,333 43,114 332 q86 8xti 1.068 1,787 2.855 6,821 Tone f _ .___.j,478 3321" - - - _ 1,8Q8 7,078 400 83 486 8x11 442 2,494 0 2,494 18,417 117; 247 3-u 2-Mahn Floor- Foyer/ Bath 228 312 0 312 4.905 3-Site Cant 66 1-5 _ 24 492 0 492 1,820{ 24 1-3 4 Front Cant......_...___.._..__..,_....__._.__.._ _ 23 598 0 596 1,839 28~ 25. 1-3 _...Y r Floor __w_.._._.._.•......._....,,,-..__..__... .__........_t,___...__. _..1,Q88 3.184 400 3.584 9.312 1491 125 125 2-5 ................p. i C:Vhvac Prolects%LENNAR - 430-B Franklin- cZfAVR rho ZZ" < a sg n Lennar TH .20: Glazing- 137.8 3,314 0 2,901 Lennar TH .20: Glazing- 2,901 8 193 0 141 141 11 P: Door-Metal - Polyurethane Core 40.8 982 0 284 284 12F-Osw: Wall-Frame, R-21 insulation In 2 x 6 stud 1109.4 5,985 0 960 cavity, no board insulation, siding finish, wood studs 960 16CR44: Roof/Ceiling-Under Attic with Insulation on Attic 1138 2,078 0 952 952 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic with Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-44 insulation 22C-10pm-t: Floor-Slab on grade, Horizontal board 88 8,093 0 0 0 insulation extends 4' under slab, the covering, R-10 insulation, passive, heavy dry or light wet soil Lennar TH-c: Floor- 468 _ _ _1,166.._ . 0 112 112 . u lots s for structure. 21,811 0 5,350 5,350 People: 2 400 460 860 Equipment: 0 p 0 Lighting: 0 0 0 Infiltration. Winter CFM. 0, Summer CFM: 0 0 0 0 0 0 0 Ventilation: Winter CFM: 77, Summer CFM: 77 6,821 1,787 1,068 2,855 Exhaust: Winter CFM: 77, Summer CFM: 77 AED Excursion: 1,268 Q 1,268 Total Building Load Totals: . 4 3,114 2,187 8,146 10,333 Total Building Supply CFM: 486 CFM Per Square ft.: 0.269 Square ft. of Room Area: 1,808 Square ft. Per Ton: 2,100 Volume (fts) of Cond. Space: 14,464 Total Heating Required Including Ventilation Air: 43,114 Btuh 43.114 MBH Total Sensible Gain: 8,146 Btuh 79 % Total Latent Gain: 2,187 Btuh 21 % Total Cooling Required Including Ventilation Air: 10,333 Btuh 0.86 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:Vhvac projectslLENNAR - 430-B Franklin- Steve.rhg MULTI-FAMILY PLAN REVIEW FOR COMPLIANCE WITH AIRCRAFT NOISE ORDINANCE Compliance with Procedures to Ensure Submitter: Noise Impact Area Adequate Noise Attenuation: Lennar Airport - MSP International Exterior wall construction: 16305 36th Ave. No. Noise Zone - 4 Vinyl Suite 600 15/32" sheathing Plymouth, MN 55446 New Infill Residence is a "COND" Tyvek wrap 952-249-3000 use in Noise Zone 4 2x6 studs 16" O.C. R-21 batt insulation with 1/2" gypsum board Roof Construction: Plan. Reviewed: IZ NV~ Q.1 t) GC6 Peaked roof with manufactured trusses 24" O.C. Roof vents H9 Shingles Information Submitted: 15# felt Annotated architectural drawings includin : 1/2" sheathing Blown insulation R-44 Windows: Atrium 5/8" gypsum board Swinging Patio Doors: Atrium Entry Doors: Therma Tru Mechanical Ventilation System: Skylights: N/A 2-ton central air conditioning unit Compliance with STC Requirements: Window, Door Frame, Perimeter and Other Seals: All window and door openings are to be caulked Average window/wall area for exterior wall: 1 with butyl-based caulk With this window/wall area ratio and STC 40 walls, windows Fireplace Chimney Cap: with an STC 30 can be used to meet the noise reduction N/A requirements; Ventilation Duct Exterior Wall Penetrations: Summa : All exterior ducts will have bends as required by the ordinance Other measures including duct bends and caulking are being taken to ensure minimum transmission of noise through the Door and Window Construction: exterior building shell so that the construction should meet Windows: Atrium (30 STC) the compatibility guidelines. Sliding Patio Doors: Atrium (30 STC) Therefore, the materials and construction as proposed should meet the requirements of the Eagan aircraft noise ordinance. Entry Doors: Therma Tru (29 STC) Skylights: N/A Review Completed (date : Z Other Exterior Wall Penetrations: Review Completed b : Tom Tamte Sill sealer between plates and blocks