3210 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate
Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted
building. The certificate shall be completed by the builder and shall list information and values of components ti
listed in Table 8. SUPERIOR
Mailing Address s or of the ffie Dwelling or Dwelling Unit CRY y, MECHANICAL
210 Riverview Avenue Eagan
Name of Residential Contracror MN License Number
Superior Companies of Minnesota Inc MB4551
THERMAL ENVELOPE RADON SYSTEM
Type: Check All That Apply X Passive (No Fan )
o v
Active (With fan and manometer or
F~ other system monitoring device)
? O vi vy. O a~ W C
Insulation Location ° A A v gq
a o 3 m ti ti
c y o y re ' O 0 5 ao 00
F 4 Z w w w w ~ a ~ Other Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or integral
Perimeter of Slab on Grade 10 X
Rim Joist (Foundation) 19 X Type in locatom interior exterior or integral
Rini Joist (1't Floor+) 19 X Type in location: interior exterior or integral
Wall 23 X
Ceiling, flat 49 X
Ceiling, vaulted x
Ba Windows or cantilevered areas 56.5 X X
Bonus room over gat-age 56.5 X X
Describe other insulated areas
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.33 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not requited per mech. code
Fuel Type NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A040E14 GPD-40 24ACB318A30 Describe:
Input in 40,000 Capacity in 40 output in 1.5 Other, describe:
Rating or Size BTUS: Gallons: Tons:
Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system:
Structure's Calculated
AFUE or 96.5 SEER: 15.5
HSPF% Calculated 9,138
Efficiency cooling load: Cftn's
round duct OR
Mechanical Ventilation System " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfms
Location offan(s), describe: Cfin's
Capacity continuous ventilation rate in cfms: 44 6 " round duct OR
Total ventilation (intermittent + continuous) rate in cfms: 87 " metal duct
Date. 7/1/2013 Revision Date: 7/1/2013 New Construction
Site Information
Address 1: Type A Unit Project
Address 2: 32 10 (~lY>'~'1/ce Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph:
Address 1: 1244 60th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square Feet: 1363 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3
Ventilation : Exhaust
Total Ventilation Capacity : 60 cfm.
Minimum Continuous Ventilation :60cfm.
Ventilation: Exhaust: 60 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented
Other Combustion. Appliances
Gas Fired Direct Vent Fireplace(s); No Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 131
Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
'Ile0*RJ 1Gt} 4- t?4>aw, S1 z : 7 K 13 Yc $ = 7Z$ Fi 3
Applicant Name (print): SAP ,~2m a, ~~vR SSignature/Date: U4 q-9 -13
Code Official (print): Signature/Date:
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I
2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application of a mechanical permit for new construction
Site address .3!21o rvibi Ave n(& Date - 9-
contractor LA?14bDL AA4165 a hGYd ,sora Y~ompleted
Y K LL)
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including ? z
Basement - finished or unfinished) 3 3 Total required ventilation
Number of bedrooms 3 Continuous ventilation q q
Section B
Ventilation Method
(Choose either balanced or exhaust only)
[l Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy [4 Exhaust only
Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm
continuous ventilation rating by more than 100%.
Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed
continuous ventilation ratio b more than 100%
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
Dnt1, t`Fvo8Vr pm th ,
tt V K
0
Section D
Controls
(Describe operation and control of the continuous ventilation
IN'f6&a_k1> CotJftrJuvu Vem-rI A to
U I
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 501.4. 1)
Powered (determined from calculations from Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4. 1)
Other, describe: N I'
Location of duct or system ventilation make-up air: Determined from make-up air opening table
Cfm 115 Size and type (round, rectangular, flex or rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
Passive (see IFGC Appendix E, Worksheet E-1) Size and type
Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at:
River Ridge Town Home Unit A
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW
Rochester, MN 55901
j
I
V A HVAC 1,<>ADs
Prepared By:
Monday, September 09, 2013
i
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.]
Minnesota Air River Ridge Town Home Unit R
Bloomington. MN 5438 Page
[Proiect Re ort
General Protect Information
Project Title: River Ridge Town Home Unit A
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
Client Address: 1244 60th Ave NW
Client City: Rochester, MN 55901
Desi n Data
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
DU Bulb Wet Bul Rel.Hum D[y Bulb- Difference
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Figures
Total Building Supply CFM: 382 CFM Per Square ft.: 0.280
Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505
Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
Building Loads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Btuh 11 %
Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent)
0.91 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
r-_ - - ~e Software F~'eiapment, Inc,
P'h+rac esid ntia! & Light Comm€ r621 H VAC Loads
r Zin River Ridge Town Home Jn t A
-Page 3,
n ~cta Air
8,1o,-~ r iratonx AN' 65 3 _ - - - -
MisceflaneOus Report
System 1 Outdoor Outdoor Indoor Indoor Grains
In.p,ut Data - BuIE~Wet Bulb Rel.Hum_- --Pa Bult~_ Difference ( j
-20 0 30 72 34.40
Winter; 73 72 35,16
Summer: 92
Q,Sizfng_ Inputs
Main Trunk, R-LLi o-uts_
j Calculate: Yes Yes
j Use Schedule: Yes Yes
1
Roughness Factor,: 0,00300 0.01000
Pressure Crop; 0.1000 in,wa,1100 ft. 0.1000 in.WCA00 ft.
450 ft./min
Minimum Velocity: 650 ft./min
Maximum Velocity: 900 ft,/min 750 ft.lmin
I Minimum Height: 0 in. 0 in.
Maximum Height; 0 in. 0 in.
infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 11,038 Cu.fi. >L 11 ,3E Cu,ft.
4,746 Cu.ft,lhr 2,539 Cu.ft.lhr
X 6,167 X 0.01 7
Total Building Infiltration: 79 CFM 42 CF
Total Building Ventilation: 0 CFM 0 CFM
i
---System 1---
infiltration & Ventilation Sensible Gain Auitiplier: 21.35 = (1.10 X 0.970X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 (0.68 X 0.970 X 35.16 Grains Difference)
infiltration & Ventilation Sensible Loss Multiplier: 93.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
9
3
i
' f
i
3
I I~
y f
3
{
C:',Users\Chad,Nt,NAIRiLDesktop\Office Doc\Sales,River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
River Ridge Town Home Unit A
Minnesota Air age 4j
Bloomington MN 55438
Load Preview Report
Sys! Sys[ Sys` Duct
Has: Net Rec ft'' Sen Lat Net Sen Htg Cig Act' Size
Scope AED', Ton' Toni rroni Areai Gain Gain! Gain Loss CFM, CFM CFM'
Building 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 38
System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9
Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9
1-Basement 104 655 206 861 5,392 72 31 31 1-4
2-Main Floor 630 3,535 399 3,934 8,797 118 166 166 2-5
3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac -Residential & Light Commercial HVAC Loads - Elite Software Development, Inc.
11 Minnesota Air River Ridge Town Home Unit A
_Bloomington, MN 55438 Pa e 5
Total Building Summa Loads
Component Area Sen Lat Sen Total
Descri tion ua Loss Gain Gain Gain
Dbl Pane Low e: Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914
Low e, u-value 0.3, SHGC 0.33
11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378
15A-10sffc-8: Wall-Basement, concrete block wall, R-10 123.5 537 0 26 26
foam board to floor, no framing, no interior finish,
filled core, 8' floor depth
R-23 wall: Wall-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090
15a-1-sffc-8: Wall- 76 421 0 22 22
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693
Insulation on Attic Floor (also use for Knee Walls and
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles 0 0
21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 258 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide
22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0 0 0
covers slab edge, turns under slab and extends 4'
horizontally, any floor cover, R-10 insulation, passive,
heavy dry or light wet soil
R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131
R-56.5 Over Open Crawl or Garage Floor
Subtotals for structure: 14,947 0 7,254 7,254
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 79, Summer CFM: 42 7,767 981 903 1,884
Ventilation:.. Winter CFM: 0,-Summer CFM; O 0 0.. _ --1 0 01
.
Total Building Load Totals: 22,714 981 8,157 9,138
Check Figures
Total Building Supply CFM: 382 CFM Per Square ft.:
Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505
Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
11 BuildinL ads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Stuh 11 %
Total Cooling Required With Outside Air: 9,138 Stuh 0.76 Tons (Based On Sensible + Latent)
0.91 Tons (Based On 75% Sensible Capacity)
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAiR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.:
Minnesota Air` River Ridge Town Home Unit A
Bloomington. MN 55438 Ea 21]
System 1 Room Load Summa _
Htg Min Run Run Clg Clg Min . Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CF.M Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Basement 104 5,392 72 1-4 352 655 206 31 31
2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166
3 2nd Floor 63. 8,525 114.._,. 2-6 -,.473._3,967-_ _ ,.376.186-.1.8.6-
11 System 1 total 1,364 22,714 304 8,157 981 382 382
System 1 Main Trunk Size: 9x9 in.
Velocity: 679 ft./min
Loss per 100 ft.: 0.117 in.wg
Coolin System Summary,
Cooling Sensible/Latent Sensible Latent Total
F-- Tons . Split B uh B uh tuh.
Net Required: 0.76 89%/11% 8,157 981 9,138
Recommended: 0.91 75%/25% 8,157 2,719 10,876
E ui ment Data
Heating -54= [tooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
n/a 0 Btuh
Latent Capacity:
l
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM