Loading...
3214 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N 110 1. 8. 1 D S U P S 1 Malting Address s of of the Me Dwelling or Dwelling Unit City RiverviewAvenue Eagan MECHANICAL Name or Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM _ Type: Check All That Apply X Passive (No Fan ) 4.., o c c Active (With fan and monometer or .2 other system monitoring device) d 0 a o ~ U ~ ao v ~ ~ ~ 0.l P] m U a'"i 'v c V Insulation Location V " N a ° ~o 'o^a i3 E m o ti c y c ,°'o c c 5 no c'b F ar Z w w w w a iR Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Run Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1st Floor+) 19 X Type in location: interior exterior or integral wall 23 X Ceiling, flat 49 X Ceiling, vaulted x Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe otherinsulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHOC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 9,138 Efficiency cooling load: Cfin's " round duct OR Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two fumaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfnts: Low: Hi : Other, describe: Energy Recover Ventilator (ERV) Capacity in clots: Low: High: Location of duet or system: Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: Cftn's Capacity continuous ventilation rate in cfins: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 187 " metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type A Unit Project Address 2: 32ry IUY6_Vie4 A rm, Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1363 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3 Ventilation : Exhaust Total Ventilation Capacity : 60 cfm. Minimum Continuous Ventilation :60cfm. Ventilation: Exhaust: 60 cfm. Combustion Appliance Water Heater. Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm). 175 Make-Up Air Total Make-Up Air Required (cfm): 131 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches Y')EC-1/jw.l 1riP1L Zoopn 612Z: 7 Y. 6 X-S = 7Z$ f, g Applicant Name (print): SSignature/Date: f►S/r' 9. 9 -13 Code Official (print): Signature/Date: 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address bJ v f'l i f p _ Date HVAC uP14bb~ CBA-IpAt4lo of MlrVrlE50f7F ,,Pompleted Contractor By (~j11 U6 Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including 2 z Basement-finished or unfinished) 13 63 Total required ventilation f Number of bedrooms 3 Continuous ventilation y Section B Ventilation Method Choose either balanced or exhaust only) Fj Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy [I Exhaust only Recovery Ventilator) - cirri of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed continuous ventilation rating by more than 100% y Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation arojp i tl~ FWOSVKS3 ppo- &L kni y, WFyp.5vKS3 Kai t4-L&6, t&rogm& 17" Section D Controls (Describe o eration and control of the continuous ventilation) IN?EG. kt, COtJ'fIIJuOUS V nI-ttt.ATlvxl Tf v t r' Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) Powered (determined from calculations from Table 501,4.1) )ntenocked with exhaust device (determined from calculation from Table 501.4. 1) Other, describe: A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm I I Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet f Sfze and type flLY7. FJOther, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: River Ridge Town Home Unit A HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 s RLU-it V-A%-,~ KVAC LOAO-S Prepared By: Monday, September 09, 2013 Elite Software Development, Inc. Rhvac -Residential & Light Commercial HVAC Loads River Ridge Town Home Unit A Minnesota Air P e Bloomington,-MN 5543 Project Report General Project Information. Project Title: River Ridge Town Home Unit A Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Desi in Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Drv Bulb Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Figures Total Building Supply CFM: 382 CFM Per Square ft.: 0.280. Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Building Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh pigs TTons (Based On Sensible + ons (Based On 75% Sensible Capacity) iVotes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM m__ _ - - - - Elite Software Development, Inc. Rhvac Residential & Light Connmerr.iai HVA.C Loads River Ridge Town Home Unit A! Minnesota Air Bkoomin ta~~ MN 5a38 pam Miscellaneous Report - System I Outdoor Outdoor Indoor Indoor Grains Input Wet_Buit~ F2ELHuln.. Dry BuIE~ - _ Difference 30 72 34.40 Winter: -20 92 73 50 72 35.16 Summer, Duct S_i: ing .lnouts_ Man rLan4c un..Q Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 X1000 Pressure Drop: 01000 in.wg./100 ft. 0.1400 in.v g,f100 f . l Minimum Velocity: 650 ft,/min 450 ft./min Maximum Velocity: 900 ft,/min 750 ft./min Minimum Height: 0 in. 0 in, Maximum Heiaht; 0 in. 0 in. Outside Air Data Winter summer Infikration: 0.430 AC/hr 0.230 AC:/hr /above Grade Volume: 91 038 Cu,ft. X 11 038 Cu.ft. 4,746 C;u.ft.ihr 2,539 Cu.ftJhr X00 1_67 :C 0.01 7 Total Building infiltration: 79 CFM 42 CFM r Total Building Ventilation: 0 CFM 0 GFM I F ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp, Difference) Infiltration Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) lnfiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) I t i j i i I z I i E ~I i' € 1 C, \\Jsers\Chad,V N,AIRiDesktop',O fice Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesta Air River Ridge Town Home Unit A o Bloomin tori M 5438 P Load Preview Report ` Has' Net Rec ft' Sens: Lat. Net' San: Sys: Sys Sys Duct Htg Clg Act Siz Scope AED Ton Ton! Ron; Area; Gain; Gain3 Gam Loss CFM CFI VI ..i Building 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9 Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9 1-Basement 104 655 206 861 5,392 72 31 31 1-4 2-Main Floor 630 3,535 399 3,934 8,797 118 166 166 2-5 3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit A Blo min on MN 5543 Pa 5 Total Building Summa Loads Component Area Sen Lat Sen Total Descri tion u Los Gain Gain Gal Dbl Pane Low e: Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914 Low e, u-value 0.3, SHGC 0.33 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10sffc-8: Wail-Basement, concrete block wall, R-10 123.5 537 0 26 26 foam board to floor, no framing, no interior finish, filled core, 8' floordepth R-23 wall: Wall-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090 15a-1-sffc-8: Wail- 76 421 0 22 22 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 258 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131 R-56.5 Over Open Crawl or Garage Floor Subtotals for structure: 14,947 0 7,254 7,254 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 79, Summer CFM: 42 7,767 981 903 1,884 Ventilation: Winter CFM:..-Summer CFM..O - 0-_ 0 0 __.............4.. Total Building Load Totals: 22,714 981 8,157 9,138 Check Fi uses , Total Building Supply CFM: 382 CFM Per Square ft.: 0.280 Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (W) of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Building Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain:. 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Stuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes . Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM - - Softsbars Development, nc. ?hvac Residential & Light Commercial H~lAC Loads Elite River Ridge Town Home Unit A , Minnesota Air Bloomin on ttiTh1 554 8 _ _ - System 1 Room Load Summa Htg Min Run Run G1gIg Min Act . Room Area Sens Htg Duct Duct Sens Lat Clg Sys k Na NameSF _._.._BtuhCFM Size .._~_.._.Vel _._._Btuh _ Btuh CF A C<t~M' --Zone 1--- ! 1 Basement 104 5,392 72 1-4 352 655 206 31 31 2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166 3 2nd Floor 630 8,525 114 2-6 473 3,967 376 X86 186 - System 1 total 1,364 22,714 304 8,157 981 382 352 System 1 Main Tank Size. 9x9 in. Velocity: 679 Urnin Loss per 100 ft.: 0.117 in.wg Cooling 5ysiem 5ummary_- Cooling SensiblslLalent Sensible ~Laten I tal - - a Btuh _ Btuh i! Tons - Net R uired~ 0,7e 89%111% - 8,157 981 p :,.,commended; 0.9.1 r_5%l25°fl - 8,157.__.,.,.__._. 2,719 10,876 { ~ e in S ste lin }fi g Type: i Model: Brand: Efficiency: Sound: Capacity: 0 Btuli ~ Sensib4e Capacity: n,a j Latent Capacity- n1a 0 Btuh 1 i g~ E 4 1 C:I,UsersvCh .c.N1,NAIR,Desktoo\0ffjce Dcc',SaI es\Rlver Ridge U n 1 t A.rtty Monday, September 09, 2013, 11:55 AM