3202 Riverview Ave - Energy Compliance Forms 11 ,
New Construction Energy Code Compliance Certificate
Per NJ 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Dm Certificate Posted
building. The certificate shall be completed by the builder and shall list information and values of components
listed in Table NI 101.8.
ManingAddressoftheDwelling orDwelling Unh C" yyMEf11R3MICAi
02 Riverview Avenue Eagan %ihal Name of Residential Contractor MN License Number
Superior Companies of Minnesota Inc MB4551
THERMAL ENVELOPE RADON SYSTEM
Type: Check All That Apply X Passive (No Fan )
w
h
T m Active (With fan and monometer or
other system monitoring device)
y -a o ~ V ~ p m
W OCI a~i C) d
~ O vs N O N 4 O
Insulation Location o z w
oa on E E d a
E E a
t° 2 w w w° w° Other Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or integral
Perimeter of Slab on Grade 10 X
Rim Joist (Foundation) 19 X Type in location: interior exterior or integral
Rile Joist (I st Floor+) 19 X Type in location: interior exterior or integral
wall 23 X
Ceiling, flat 49 X
Ceiling, vaulted X
Bay Windows or cantilevered areas 56.5 X X
Bonus room over garage 56.5 X X
Describe other insulated areas
windows & Doors Heating or cooling Ducts Outside Conditioned Spaces
Average -Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space
Solar He Gain Coefficient (SHGC): 0.33 R-value
MECH NICAL SYSTEMS Make-up Air Select aType
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel T NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A040E14 GPD-40 24ACB318A30 Describe:
Input in 40,000 Capacity in 40 Output in 1.5 Other, describe:
Rating o Size BTUS: Gallons: Tons:
Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system:
Structure's Calculated
AFUE or 96.5 SEER: 15.5
HSPF%
Calculated 9,138
Efffciee cooling load: Cfm's
" round duct OR
Mechanical Ventilation System " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): Not required per mech. code
Select Ty X Passive
Heat ecover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe:
Ener Recover Ventilator (ERV) Capacity in efins: Low: High: Location of duct or system:
Conf uous exhausting fan(s) rated capacity in efins:
Loc ion of fan(s), describe: Cfin's
Cap city continuous ventilation rate in cfins: 44 6 " round duct OR
Tota
11 ventilation (intermittent + continuous) rate in cfins: 87 " metal duct
Date: 7/1/2013 Revision Date: 7/1/2013 New Construction
Site Information
Address 1: Type A Unit Project
Address 2: 3 2a l~;Y" Avg-44_0 Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 fax: 507-281-9807 Cell Ph:
Address 1: 1244 80th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square feet: 1363 sq. ft., Avg. Ceiling Ht: 8 ft. Number of Bedrooms. 3
Ventilation : Exhaust
Total Ventilation Capacity : 60 cfm.
Minimum Continuous Ventilation :60cfm.
Ventilation: Exhaust: 60 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler: Direct Vent/Seaied Combustion Input BTUs: 40,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): No Gas fired Power Vent Fireplace(s): No
Gas Fired Natural Draft fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 131
Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
rti3E~Jfj.1 ~Gt}L zcopry S1 ZC : 7 K 13 x $ = 72-F Ft3
Applicant Name (print): 5NPr~,v/z -sSignature/Date: -13
Code Official (print): SignaturelDate:
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page ]
20109 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application of a mechanical permit for new construction
Site address 'U&Vi to Au en U p Date
L Ll _q_
Hvac 'ZUA?UbDP_ ELIMAan(I t:5 MJry dESOrA yX:ompieted
Contractor ey(~.
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 orEquation 11-1)
Square feet (Conditioned area including 2
Basement - finished or unfinished) 13 Total required ventilation
Number of bedrooms 3 Continuous ventilation q q
Section B
Ventilation Method
(Choose either balanced or exhaust only)
❑ Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only
Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm
continuous ventilation rating by more than 100%.
Low cfm: I I High cfm: Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating by more than 100%
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
rojPn it. tIrV d$V ts3 PP Lt►' Wtip-mv, q4 I
G ktV a 6mmomw
d 5p
0 l 75
Section D
Controls
(Describe operation and control of the continuous ventilation)
i! U i t T
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 501.4. 1)
Powered (determined from calculations from Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4.1)
Other, describe:
Location of duct or system ventilation make-up air: Determined from make-up arc opening table
Cfm I I5 Size and type (round, rectangular, flex or rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
Passive (see IFGC Appendix E, Worksheet E-1) Size and type Dud,
Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at:
I
River Ridge Town Home Unit A
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW i
Rochester, MN 55901
.5! _
E11-
j„
HVA LO
Prepared By:
Monday, September 09, 2013
Elite Software Development, Inc.
Rhvac -Residential Z3< Light Commercial HVAC Loads River Ridge Town Home Unit A
Minnesota Air Pa Page 2
Bloomin ton MN 55438
Pro -ect Re ort
General Project Information
Project Title: River Ridge Town Home Unit A
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
i Client Address: 1244 60th Ave NW
` Client City: Rochester, MN 55901
Design Data - l
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1,000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb W t uIb Rel.Hum pD[y But Q1 erence
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Figures 0.280
Total Building Supply CFM: 382 CFM Per Square ft..
1,364 Square ft. Per Ton: 1,505
Square ft. of Room Area:
Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
~B~ uil ina Loads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Stuh 11 %
Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent)
0.91 Tons (Based On 75% Sensible Capacity)
Notes _ _
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
i
`C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
j
MRhvac innesota -Residential & Light Commercial HVAC Loads Elite SoRiverftRidgware Ridge Town Nome Development, Unit Inc.
A ,
Minnesota Air Page 3
Bloomington MN 55438
Miscellaneous Report
Outdoor Outdoor Indoor. Indoor Grains
System 1
30 _ D Bulb.,_
72 Difference -20 0 34.40
Input Dafa D Bulb Wet Bulb Rel.Hum.
Winter. 92 73 50 72 35.16
Summer:
Duct Sizing Inputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in. -71
Outside Air Data Summer
Winter
Infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 11.038 Cu.ft. X 11.038 Cu.ft.
4,746 Cu.ft./hr 2,539 Cu.ft./hr
X 0.0167 X 0,0167
Total Building Infiltration: 79 CFM 42 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier. 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
i
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit A
Bloomington MN 55438 Page 4
Load Preview Report
Has Net. Rec! ft2' San: Lat: Net Sen Sys; Sys. Sys: Duct
Htg Clg Act
Scope AED Ton; Ton, /Ton; Areal Gain: Gain: Gain Loss CFM CFM CFM size
Building 0.76 0.91 1,505 1,384 8,157 981 9,138 22,714 304 382 382
System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9
Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9
1-Basement 104 655 206 861 5,392 72 31 31 1-4
2-Main Floor 630 3,535 399 3,934 8,797 118 188: 166 2-5
3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013,11:55 AM
f
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit A.
d ~ Page 5
Bloomington MN 55438 -
Total Building Summa Loads
Component Area Sen Lat Sen Total
Description 01 an Loss Gain Gain Gain
Dbl Pane Law e` Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914
Lowe, u-value 0.3, SHGC 0.33
11 P: Door-Metal Polyurethane Core 42 1,120 0 378 378
15A-10sffc-8: Wall-Basement, concrete block wall, R-10 123.5 537 0 26 26
foam board to floor, no framing, no interior finish,
filled core, 8' floor depth
R-23 wall: Wail-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090 I
15a-1-sffc-8: Wall- 76 421 0 22 22
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693
Insulation on Attic Floor (also use for Knee Walls and
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles 0
21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 2'58 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide 0 0
22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0
covers slab edge, turns under slab and extends 4'
horizontally, any floor cover, R-10 insulation, passive,
heavy dry or light wet soil
R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131
j R-56.5 Over Open Crawl or Garage floor
Subtotals for structure: 14,947 0 7,254 7,254
People: 0 0 0 0
Equipment: 0 0 00
Lighting: 0 0
Ductwork: 0 0 0
Infiltration: Winter-CFM: 79, Summer CFM: 42 7,767 981 903 1,884
Ventilation;- Wnter CFM_: 0,.Summer CFM;-O- - a........................ o --0- - 0.1
Total Building Load Totals: 22,714 981 8,157 9,138
Check Fi urea
Total Building Supply CFM: 382 CFM Per Square ft.: 0.280
Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505
Volume (ft3) of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
Building Loads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Btuh 11 %
Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible } Latent)
0.91 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
L C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.{
Minnesota Air River Ridge Town Home Unit A
Bloomington MN 55438 F'aae 6
j System 1 Room Load Summary
Htg Min Run Run Gig Gig Min Act i
Room Area Sens Htg Duct Duct Sens Lat Cig Sys I
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Basement 104 5,392 72 1-4 352 655 206 31 31
2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166
3 2nd Floor 630 8,52-- __.114 _ 2-6 473 ..3,967 _ ..376--- - - 186- _ . 86
-
System 1 total 1,364 22,714 304 8,157 981 382 3,82
System 1 Main Trunk Size: 9x9 in.
Velocity: 679 ft./min
Loss per 100 ft.: 0.117 in.wg
cooling system Summa
F Cooling Sensible/Latent - Sensible Latent Total
Tons Split- Btuh Btuh Btuh
Net Required: 0.76 89%/11% 8,157 981 9,138
Recommended: 0.91 75%/25% 8,157 2,719 10,876
E ui ment Data
Heating System Cooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Stub
Latent Capacity: n/a 0 Stuh
C:\Users\C had. MNAI R\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM