Loading...
3202 Riverview Ave - Energy Compliance Forms 11 , New Construction Energy Code Compliance Certificate Per NJ 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Dm Certificate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. ManingAddressoftheDwelling orDwelling Unh C" yyMEf11R3MICAi 02 Riverview Avenue Eagan %ihal Name of Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) w h T m Active (With fan and monometer or other system monitoring device) y -a o ~ V ~ p m W OCI a~i C) d ~ O vs N O N 4 O Insulation Location o z w oa on E E d a E E a t° 2 w w w° w° Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rile Joist (I st Floor+) 19 X Type in location: interior exterior or integral wall 23 X Ceiling, flat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas windows & Doors Heating or cooling Ducts Outside Conditioned Spaces Average -Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar He Gain Coefficient (SHGC): 0.33 R-value MECH NICAL SYSTEMS Make-up Air Select aType Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel T NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating o Size BTUS: Gallons: Tons: Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 9,138 Efffciee cooling load: Cfm's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Ty X Passive Heat ecover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: Ener Recover Ventilator (ERV) Capacity in efins: Low: High: Location of duct or system: Conf uous exhausting fan(s) rated capacity in efins: Loc ion of fan(s), describe: Cfin's Cap city continuous ventilation rate in cfins: 44 6 " round duct OR Tota 11 ventilation (intermittent + continuous) rate in cfins: 87 " metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type A Unit Project Address 2: 3 2a l~;Y" Avg-44_0 Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 fax: 507-281-9807 Cell Ph: Address 1: 1244 80th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square feet: 1363 sq. ft., Avg. Ceiling Ht: 8 ft. Number of Bedrooms. 3 Ventilation : Exhaust Total Ventilation Capacity : 60 cfm. Minimum Continuous Ventilation :60cfm. Ventilation: Exhaust: 60 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Seaied Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas fired Power Vent Fireplace(s): No Gas Fired Natural Draft fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 131 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches rti3E~Jfj.1 ~Gt}L zcopry S1 ZC : 7 K 13 x $ = 72-F Ft3 Applicant Name (print): 5NPr~,v/z -sSignature/Date: -13 Code Official (print): SignaturelDate: 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page ] 20109 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address 'U&Vi to Au en U p Date L Ll _q_ Hvac 'ZUA?UbDP_ ELIMAan(I t:5 MJry dESOrA yX:ompieted Contractor ey(~. Section A Ventilation Quantity (Determine quantity by using Table N1104.2 orEquation 11-1) Square feet (Conditioned area including 2 Basement - finished or unfinished) 13 Total required ventilation Number of bedrooms 3 Continuous ventilation q q Section B Ventilation Method (Choose either balanced or exhaust only) ❑ Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low cfm: I I High cfm: Continuous fan rating in cfm (capacity must not exceed continuous ventilation rating by more than 100% Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation rojPn it. tIrV d$V ts3 PP Lt►' Wtip-mv, q4 I G ktV a 6mmomw d 5p 0 l 75 Section D Controls (Describe operation and control of the continuous ventilation) i! U i t T Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4. 1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4.1) Other, describe: Location of duct or system ventilation make-up air: Determined from make-up arc opening table Cfm I I5 Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type Dud, Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: I River Ridge Town Home Unit A HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW i Rochester, MN 55901 .5! _ E11- j„ HVA LO Prepared By: Monday, September 09, 2013 Elite Software Development, Inc. Rhvac -Residential Z3< Light Commercial HVAC Loads River Ridge Town Home Unit A Minnesota Air Pa Page 2 Bloomin ton MN 55438 Pro -ect Re ort General Project Information Project Title: River Ridge Town Home Unit A Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical i Client Address: 1244 60th Ave NW ` Client City: Rochester, MN 55901 Design Data - l Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1,000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb W t uIb Rel.Hum pD[y But Q1 erence Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Figures 0.280 Total Building Supply CFM: 382 CFM Per Square ft.. 1,364 Square ft. Per Ton: 1,505 Square ft. of Room Area: Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 ~B~ uil ina Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Stuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes _ _ Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i `C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM j MRhvac innesota -Residential & Light Commercial HVAC Loads Elite SoRiverftRidgware Ridge Town Nome Development, Unit Inc. A , Minnesota Air Page 3 Bloomington MN 55438 Miscellaneous Report Outdoor Outdoor Indoor. Indoor Grains System 1 30 _ D Bulb.,_ 72 Difference -20 0 34.40 Input Dafa D Bulb Wet Bulb Rel.Hum. Winter. 92 73 50 72 35.16 Summer: Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. -71 Outside Air Data Summer Winter Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 11.038 Cu.ft. X 11.038 Cu.ft. 4,746 Cu.ft./hr 2,539 Cu.ft./hr X 0.0167 X 0,0167 Total Building Infiltration: 79 CFM 42 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier. 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit A Bloomington MN 55438 Page 4 Load Preview Report Has Net. Rec! ft2' San: Lat: Net Sen Sys; Sys. Sys: Duct Htg Clg Act Scope AED Ton; Ton, /Ton; Areal Gain: Gain: Gain Loss CFM CFM CFM size Building 0.76 0.91 1,505 1,384 8,157 981 9,138 22,714 304 382 382 System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9 Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9 1-Basement 104 655 206 861 5,392 72 31 31 1-4 2-Main Floor 630 3,535 399 3,934 8,797 118 188: 166 2-5 3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013,11:55 AM f Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit A. d ~ Page 5 Bloomington MN 55438 - Total Building Summa Loads Component Area Sen Lat Sen Total Description 01 an Loss Gain Gain Gain Dbl Pane Law e` Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914 Lowe, u-value 0.3, SHGC 0.33 11 P: Door-Metal Polyurethane Core 42 1,120 0 378 378 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 123.5 537 0 26 26 foam board to floor, no framing, no interior finish, filled core, 8' floor depth R-23 wall: Wail-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090 I 15a-1-sffc-8: Wall- 76 421 0 22 22 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 0 21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 2'58 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 0 0 22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131 j R-56.5 Over Open Crawl or Garage floor Subtotals for structure: 14,947 0 7,254 7,254 People: 0 0 0 0 Equipment: 0 0 00 Lighting: 0 0 Ductwork: 0 0 0 Infiltration: Winter-CFM: 79, Summer CFM: 42 7,767 981 903 1,884 Ventilation;- Wnter CFM_: 0,.Summer CFM;-O- - a........................ o --0- - 0.1 Total Building Load Totals: 22,714 981 8,157 9,138 Check Fi urea Total Building Supply CFM: 382 CFM Per Square ft.: 0.280 Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft3) of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Building Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible } Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. L C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.{ Minnesota Air River Ridge Town Home Unit A Bloomington MN 55438 F'aae 6 j System 1 Room Load Summary Htg Min Run Run Gig Gig Min Act i Room Area Sens Htg Duct Duct Sens Lat Cig Sys I No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 104 5,392 72 1-4 352 655 206 31 31 2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166 3 2nd Floor 630 8,52-- __.114 _ 2-6 473 ..3,967 _ ..376--- - - 186- _ . 86 - System 1 total 1,364 22,714 304 8,157 981 382 3,82 System 1 Main Trunk Size: 9x9 in. Velocity: 679 ft./min Loss per 100 ft.: 0.117 in.wg cooling system Summa F Cooling Sensible/Latent - Sensible Latent Total Tons Split- Btuh Btuh Btuh Net Required: 0.76 89%/11% 8,157 981 9,138 Recommended: 0.91 75%/25% 8,157 2,719 10,876 E ui ment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Stub Latent Capacity: n/a 0 Stuh C:\Users\C had. MNAI R\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM