Loading...
3206 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per N1 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. o 1 11Malting Address s of the the D Dwelling or Dwelling Unit Cft MECHANICAL 32 Riverview Avenue Eagan` Name of Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) 0 0 a y Active (With fan and manometer or i, other system monitonng device) 0. d Q G1 obi U 0 T N a a Insulation Location o z g .9- U a w .40 o N o a a o o m on l - . z v. w w w a ri~ Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1't Floor+) 19 X Type in location: interior exterior or integral wall 23 X Ceiling, flat 49 X Ceiling, vaulted x Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select aTvpe Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACS318A30 Describe: Input in 40'000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 18,380 Heat Gain: 5,630 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 5,630 11 Efficiency cooling load: Cfin's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up fitmace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in efrns: Low: HOther, describe: Energy Recover Ventilator (ERV) Capacity in chins: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in elms: Location offan(s), describe: Cbm's Capacity continuous ventilation rate in chns: 44 6 "round duct OR Total ventilation (intermittent + continuous) rate in chns: 87 " metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type B Unit Project Address 2: 32C71p QiVervid.LZ /{VPn,,k Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Fumace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 140 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches mcCfJ9a1CAL adv.. 51 ze-: Yg = $91, F -r3 Applicant Name (print):S,4p,5Aj-V_M nr~~ IL/19 Signature/Date: 9 f -13 Code Official (print): Signature/Date: cQ 2004 CenterPoint Energy Minn egasco. 2004 Mechanical Code Guidelines. Page l 2009 Mechanical & Energy Code - Ventilation, Mal<eup, and Combust on Air Calculations Please submit at time of application of a mechanical pe; mit for new construction Site address i I~iQcrd (e_vo A ob-)'L' Date N~/° tE 4i tDQ ~'?h { ~S us Virtlt' gg A £ mpteted 1 L_4t~ V-11 Contractor 4~tz btt~ f~E tIY~_~1 By Section A Ventilation Quantity -e i t' 1 toetermine quantity by usin_ Tnbie N1 nt2 or Equation 111 Square feet (Conditioned area inciudmg 1 Basement - finished or unfinished) Total required ventilation t Ifs Number of bedrooms !Continuousventit-tion ~ Section 3 Ventilation Method ,Choose either balanced of exhaust only) Balanced, HRV (Neat Recovery VJ r-,612tor) or ERV (Exnergy X Exhaust only Peccvery Venti;ator) - cfm of unit in tow must not exceed Continuous fan m6ng cfm continuous ventilation rating by more than 100%. k o cfm: High crm: Continuous r n rating in cfrn (capacity must not exceed I continuous nil tion rating by more than loo".) 35 Section C Ventilation Fan Schedule Description ~ Location Continuous ~ ; otal Ventilation k ~ i ft(D K 3 [tare 00- e)PrH GOM 35 20 E g t;~ A A I LVD5vu~3 i"tee E~~~~1!lrCr i, I Section D Controls ;Describe operation End control of the continuous ventilation) TNt>=t,.u?A ~ Ct~V'r`r fi ~ CJUS U r;t~i ~ t L R i fOtJ CC r~Tt~DL- ~(aSwl-r'r._.} FOIL MC.Ktmul' g9M1-tL_k-ClprJ LDtJCML 1Section F Make-up air for ventilation Passive (determined from calculations from Table 501A 1) ~ow,ered (determined from calculations from Table 501.4. Inferlacf;ed oath exhaust device (deteimined from calculaiion from Table 50.4-1) Other, describe: A Location of duct or system ventilation make-Up air, Detetmined from make-up air opening table C.F l~ Size end type (round, re ~flexor P) L_~ - Section F Blake-up air for combustion No rewired per mechanical code (P at nespheric or power vented appliances) Passive (see iFGC Appendix E, VvCrk,sh et E-1) Size and type ether, describe. Notes: it .ructions and example for s are - vairabte at the. Building Safety vdebsite and at the Building Safety ofF.,ce- This form must be submitted at the time of application of a mechanical permit for new, construction. Additional forms may be dovmiloaded and printed al River Ridge "own Home Unit 8 HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 i 4 _ tw - ~p' Mr, Rn HV Prepared By: Monday, September 09, 2013 Rhvac - Residential & Light Commercial HVAC Loads t Elite Software Development, Inc. Minnesota Air r River Ridge Town Home ane B Bloomington, MN 55438 Project Report General Proiect Information Project Title: River Ridge Town Home Unit B Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 a _ Desi n Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains D Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 1 Check Figures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour) 1.1 Building Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 . % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) I Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc i Minnesota Air h River Ridge Town Home Unit B, i Bloomington MN 55438 Pane 3 Miscellaneous Report ' System 1 Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel Hum Dry Bulb Difference Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 Duct Sizing Inputs Main Trunk nouts Caiculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wgJ100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AClhr 0.230 AC/hr Above Grade Volume: X 12.517 Cut. X 12.517 Cu.ft. 5,382 Cu.ft./hr 2,879 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 90 CFM 48 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration & Ventilation Sensible Gain Multiplier. 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) a C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM ! Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc, Minnesota Air River Ridge Town Home Unit B I Bloomington. MN 55438 Page 4 Load Preview Report Has Net. Rec ft.=Sen Lat Net Sen Sys: Sys Sys: Duct scope AED Ton Ton: /Ton; Area: Gain! Gain! Gain Loss Htg Clg Act SIZE t CFM: CFM CFM Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 2416 7x7 Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 1-Basement 543 1,117 528 1,645 7,498 100 52 100 1-6 2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5 3-Upper Floor 510 1,726 275 2,001 5,017 67 81 67 1-5 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B LBloomington, MN 5543$ Page 5 i { Total Building Summa Loads Component Area Sen Lat Sen Total ( Description Quan Loss Gain Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295 Low e, u-value 0.3, SHGC 0.33 7A-1: Giazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195 or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23 foam board to 3', no framing, no interior finish, open core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121 R-56.5 Over Open Crawl or Garage Floor Subtotals for structure: 9,573 0 3,308 3,308 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: . 0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 186 186 Total Building Load Totals: 18,380 1,112 4,518 5,630 Check Fi ures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Buildin Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. - All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit 8 Bloomin ton MN 55438 Page 6 i System 9 Room Load Summary Htg Min Run Run Clg Cig Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys i No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 543 7,498 100 1-6 511 1,117 528 52 100 2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79 ---3 Upper-Floor- 510 5,017 - --67 1-5 493 1,726 - 275....- $1_.._.......'67. . System 1 total 1,563 18,380 246 4,518 1,112 212 246 System 1 Main Trunk Size: 7x7 in. Velocity: 723 ft./min Loss per 100 ft.: 0.157 in.wg [Cooling System Summa Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.47 80%/20% 4,518 1,112 5,630 Recommended: 0.50 75%/25% 4,518 1,506 6,023 Equipment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 8tuh Latent Capacity: n/a 0 Btuh I C:\Users\Chad.MNAIR\Desktop\Otfice Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM