3190 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8. Mailing Address of the Dwelling or Dwelling Unit Cirp SUPERIO MECHANICAL 31W0 Riverview Avenue Eagan Name of Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X passive (No Fan ) o a y Active (With fan and manometer or E a _T other system monitoring device) a r a, .2 :E Oa aroi ~ ,0 41 c w o Insulation Location z 6 ~ v p o N N it oo ao 10 4-i Z w w ° wo :X i ii Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1n Floor+-) 19 X Type in location: interior exterior or integral wall 23 X Ceiling, flat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors eating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select aType Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 22,714 Heat Grain: 9,138 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF°/O Calculated 9,138 Efficiency cooling load: Cfin's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up funiace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in efnis: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity in efris: Low: High: Location ofduct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), dcxcribe: Cfin's Capacity continuous ventilation rate in cfins: 44 6 " round duel OR Total ventilation (intermittent + continuous) rate in cfms: 87 " metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type A Unit Project Address 2: 13 (9 ,i 'II Aven- ~ Lot: Biock: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Pelson: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1363 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3 Ventilation : Exhaust Total Ventilation Capacity 80 cfm. Minimum Continuous Ventilation :60cfm. Ventilation: Exhaust: 60 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 independently Vented Furnace/Boiler. Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 131 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches ~33er~rRa t~ L t~~Qprr 51 u : 7 x 13 x = 7ZS FT3 Applicant Name (print): SHPF~,vR n~Er Jr,~-_-sSignature/Date: f 4 f- "13 Code Official (print): Signature/Date: 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address 4 l 9 y p ,•y ri ui uenu p . Date 117--19 Cont ctor ttt'L2tb1 1pAf1tr;5 NS1tYrlE50iiQom8pletedl1el y Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including 2 tt Basement -finished or unfinished) 13 {0 Total required ventilation ,0F t'1 Number of bedrooms Continuous ventilation q Y Section B Ventilation Method (Choose either balanced or exhaust only) Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - cfrn of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low cfm: High cfm: Continuous fan rating in dm (capacity must not exceed continuous ventilation rating by more than 100%) Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation tint, 5,Dn i e, IrvO&V r-S3 1 Li PP ww w y4 1% WS c Wryo 5VK 1.9 d no 0 175 Section D Controls (Describe operation and control of the continuous ventilation) IN'f6C t, COATI MU OUS VBNfli ATIcYJ J-reDL "6(1-ft-14 FOP MptlyALAM V 'I T Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4. 1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4. 1) Other, describe: t p Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm I 1 Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type L„ a Durk Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: River Ridge Town Home Unit A HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 b AML AIM'r ra ..-.n IV RHV`A- --C- HVAC LoAzs Prepared By: Monday, September 09, 2013 i I Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. River Ridge Town Home Unit A Minnesota Air i Pag i Bloomington MN 55438 e 2 Project Report General Project Information Project Title: River Ridge Town Home Unit A Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Design Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains r nce Dry Bulb Wet Buib I Hum DrBu_lb_ Diffe Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Figures 0 280 Total Building Supply CFM: 382 CFM Per Square ft.. Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Buildin Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) . Notes _ Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM . Software Development, Inc Rhvac -Residential & Light Commercial HVAC Loads Elite River Ridge Tower Home Unit A Minnesota Air Pa e 3 Bloomington, MN 55438 Miscellaneous Report t System 1 Outdoor Outdoor Indoor Indoor _ Grains ' - Input Data D Bulb Wet Bulb Rel.H 30 m D Bulb Difference Winter. -20 0 72 34.40 Summer: 92 73 50 72 35.16 [Duct 'Sizin In uts Main Trunk Ru out Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Summer Winter Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 11.038 Cu.ft. X 11.038 Cu.ft. 4,746 Cu.ft./hr 2,539 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 79 CFM 42 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0:68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) . i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM I I Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, tnc. River Midge Town Home Unit A I !Minnesota Air Page 4 I I Bloomington MN 55438 Load Preview Report Sys'. Sys Sys Duct Has Net Rec ft Z Sen Lat Net Sen Htg Clg Act Size Scope AED: Ton Ton: lion? Area; Gain' Gain Gain Loss CFM CFM CFM _ Building 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9 Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9 1-Basement 104 655 206 861 5,392 72 31 31 1-4 2-Main Floor 630 3,535 399 3,934 8,797 118 166 166 2-5 3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6 t C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A,rhv Monday, September 09, 2013,11:55 AM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. River Ridge Town Home Unit A Minnesota Air Page 5 Bloomin ton MN 55438 [Total Buildinq Summary Loads F mponent Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914 Low e, u-value 0.3, SHGC 0.33 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10sffc-8: Wall-Basement, concrete block wail, R-10 123.5 -537 0 26 26 foam board to floor, no framing, no interior finish, filled core, 8'fioordepth 1,090 1,090 R-23 wall: Waii-Frame, , R-23 insulated wall 1237.2 4,939 0 15a-1-sffc-8: Wall- 76 421 0 22 22 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 0 0 0 21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 258 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 0 0 0 22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131 R-56.5 Over Open Crawl or Garage Floor Subtotals for structure: 14,947 0 7,254 7,254 People: 0 p 0 0 Equipment: 0 0 Lighting: 0 0 0 Ductwork: 0 0 Infiltration: Winter CFM: 79, Summer CFM: 42 7,767 981 903 1,884 Ventilation: Winter CFM: 0,, Summer-CFM - - - - - - - - 0- - - - - Total Building Load Totals: 22,714 981 8,157 9,938 Check Fi ures Total Building Supply CFM: 382 CFM Per Square ft.: 0280 Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Building Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 1 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit A Bloomington MN 55438 Pa e6 i System I Room Load Summary Htg Min Run Run Cig C1g Min. Act I Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 104 5,392 72 1-4 352 655 206 31 31 2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166 3 2nd Floor 630..--- 8 525 - - ---114 - - 2-6- 473_.._ 3,967 - 376 _ 1136 - 186 8,157 981 382 382 System 1 total 1,364 22,714 304 System 1 Main Trunk Size: 9x9 in. Velocity: 679 ft./min Loss per 100 ft.: 0.117 in.wg Coolmq System Summary Cooling ` Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.76 89%/11% 8,157 981 9,138 Recommended: 0.91 75%/25% 8,157 2,719 10,876 E u' men# Data Heating System Cooing System Type: Model: Brand: Efficiency: Sound: Capacity: 0 Btuh Sensible Capacity: n/a Latent Capacity: n/a 0 Btuh i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM