Loading...
3192 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted building. The certificate shall be completed by the builder and shall list information and values ofeomponents listed in Table N1101.8. Mailing Address of the Dwelling or Dwelling Unit City SUPERIOR y MECftAAf tCAL X12 Riverview Avenue Eagan Name of Residential Contractor MN License Nundrer Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan) w o nt a T Active (With fan and monometer or other system monitoring device ) m b c ea o d A _O V N G d Insulation Location a: 0 z v p w I° Z w w :wo wo '64 i>? Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rif Joist (1" Floor) 19 X Type in location: interior exterior or integral wan 23 X Ceiling, flat 49 X Ceiling, vaulted X Bay Widows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors ating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one dodr) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Wake-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat boss: 18,380 Heat Gash: 5,630 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 5,630 Efficiency cooling load: Cfm's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in efins: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), desaibe: Cfin's Capacity continuous ventilation rate in cfins: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in efins: 87 " metal duct I I Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type B Unit Project Address 2: x/42 9,iVWVidu 3 A\j} Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler. Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent f=ireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 140 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches mc,~l~RL Size: ~ir>kg^ a9~F;3 Applicant Name (print):S~►Pc~~aZM1~ig9j9"Signature/Date: 9- 9,^ Code Official (print): Signature/Date: 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code -Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address !J/ fl IZWE(v ftg) A vend b Date 9 3 HVAC uP94D&, UMPANIE6 o6MrrtrStsSbrt"A C mpleted p9h G Contractor By rJt 1_zJ Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including-1 Basement - finished or unfinished) 12 DD Total required ventilation _I Number of bedrooms Continuous ventilation ' 35 Section B Ventilation Method (Choose either balanced or exhaust only Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low cfm: High cfm: I Continuous fan rating in cfm (capacity must not exceed continuous ventilation rating by more than 100% 35 Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation R4A rtt #FJDSVic 3 U.ppa- Lae- f)PrR kaom 8D NOWWL VY_S3 IKIRIM ISATUEOM 50 t21~ISt~E~~~ Ktrct+~J 1 57 Section D Controls (Describe operation and control of the continuous ventilation) IN rg"AL CLAW! i M U ouS V aA1f t LATfDAJ GD N-rkDt_ tflALL 8MIT-A Poe MkLIMUM 119M1't Ar C>J mg-FeDL Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 50 Other, describe: N' A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm 1 ~a Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Q Passive (see IFGC Appendix E, Worksheet E-1) Size and type it Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: i River Ridge Town Home Unit B HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 a Prepared By: Monday, September 09, 2013 . Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B IBloomington MN 55438 Page 2 1 Pro ect Report -771 General Project Information Project Title: River Ridge Town Home Unit B Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Desi n Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor indoor Grains Qrv Bulb We Bulb a um Der Bulb Di r ce Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Fi lures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 13uilding Is Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) G Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B' Bloomington MN 55438 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Indoor Indoor Grains In ut Data D Bulb Wet Bulb Rel.Hum D Bulb Difference Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 Duct Sizing inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wgA00 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 12.517 Cu.ft. X 12.517 Cu.ft. 5,382 Cu.ft./hr 2,879 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 90 CFM 48 CFM Total Building Ventilation: 0 CFM 0 CFM --System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) i I C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential s: Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington, MN 55438 Page 4 Load Preview Report Has Net Rec ft.2 Sen Lat` Net Sen Sys Sys Sys; Duct L i C! Act: Scope AED Ton Ton /Ton; Area. Gain; Gain; Gain Loss CFM CFM° CFM Size Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 248 System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 1-Basement 543 1,117 528 1,645 7,498 140 52 100 1-6 2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5 3-Upper Floor 510 1,726 275 2,001 5,017 67 81 67 1-5 I L C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit Bl Bloomington. MN 55438 Page 5 ! Total Building Summa Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain' Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295 Low e, u-value 0.3, SHGC 0.33 7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195 or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23 foam board to 3', no framing, no interior finish, open core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0 or more fleet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121 R-56.5 Over Open Crawl or Garage Floor Subtotals for structure: 9,573 0 3,308 3,308 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 90, Sommer CFM: 48 8,807 1,112 1,024 2,136 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 186 186 Total Building Load Totals: 18,380 1,112 4,518 5,630 Check Figures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft) of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Building Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, inc. Minnesota Air River Ridge Town Home Unit B Bloomington, MN 55438 Page 6 System 1 Room Load Summa Htg Min Run Run Clg Cig Min Act Room Area Sens Htg Duct Duct Sens Lat Cig Sys No Name SF Btuh CFM Size Vei Btuh Stuh CFM CFM ---Zone 1--- 1 Basement 543 7,498 100 1-6 511 1,117 528 52 100 2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79 3 Upper Floor_ 510 -6,017._ 67..-.- 1-5 493 1,726 275 - 81 67. System 1 total 1,563 18,380 246 4,518 1,112 212 246 System 1 Main Trunk Size: 7x7 in. Velocity: 723 ft./min Loss per 100 ft.: 0.157 in.wg Cooling System Summary Cooling ` Sensible/Latent Sensible Latent Total . Tons Split Btuh Btuh Btuh Net Required: 0.47 80%/20% 4,518 1,112 5,630 Recommended: 0.50 75%/25% 4,518 1,506 6,023 Equipment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM