3196 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate
Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certirtcate Posted
building. The certificate shall be completed by the builder and shall list information and values of components
listed in Table NI 101.8.
Mailing Address or the Dwelling or Dwelling Unit MECHANICAL
City .
Aqj* Riverview Avenue Eagan
Name or Residential Contractor RAN License Number
Superior Companies of Minnesota Inc MB4551
THERMAL ENVELOPE RADON SYSTEM
Type:. Check All That Apply X Passive (No Fan )
w
o ar
ti a
a T Active (With fan and manometer or
E~ other system monitoring device )
o - e
O a C y'~ U v L d ~
`t CA U 4) b
`a C o a v o obi w U°
Insulation Location o z 9 4 v w
L (d
E° z w w w° w° :2~ ix a Other Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or integral
Perimeter of Slab on Grade 10 X
Rim Joist (Foundation) 19 X Type in location: interior exterior or integral
Rim Joist (lrt Floor) 19 X Type in location: interior exterior or integral
Wall 23 X
Ceiling, flat 49 X
Ceiling, vaulted X
Bay Windows or cantilevered areas 56.5 X X
Bonus room over garage 56.5 X X
Describe other insulated areas
Windows & Doors eating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.33 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A040E14 GPD-40 24ACB318A30 Describe:
Input in 40,000 capacity in 40 Output in 1.5 Other, describe:
Rating or Size BTUS: Gallons: Tons:
Heat Loss: 18,380 Heat Gain: 5,630 Loeation of duct or system:
Structure's Calculated
AFUE or 96.5 SEER: 15.5
HSPF%
Calculated 5,630
Efficiency cooling load: Cfm's
" round duct OR
Mechanical Ventilation System "metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up filrnace): Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms: Low: High: Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfins:
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms: 44 6 " round duct OR
Total ventilation (intermittent + continuous) rate in cfins: 87 "metal duct
Date: 7/1/2013 Revision Date: 7/112013 New Construction
Site Information
Address 1: Type B Unit Project
Address 2:.31 176 1,tvex Vim Ate Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph:
Address 1: 1244 60th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2
Ventilation : Exhaust
Total Ventilation Capacity : 45 cfm.
Minimum Continuous Ventilation :45cfm.
Ventilation: Exhaust: 45 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 140
Passive Make-Up, Round Rigid: 6 inches or Insulated flex: 7 inches
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
me ,~tGRt. Size: -),t..ii, Y_ g,:: ,9t, F,,3
Applicant Name (print): p4L-1o6lik-4Signature/Date: _-9>3
Code Official (print): Signature/Date:
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1
2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application ofa mechanical permit for new construction
Site address G I iz" tto -A timab Date 9-9-
(O~ r
Hvac uP tU± Gt>APArâ–ºIM ofMli{tlESarA C mpleted p,b
Contractor BY }~jf
Section A
Ventilation Quantity
(Determine quantityby using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including ~~J ~M, 1 !a
Basement - finished or unfinished) (L tit/ Total required ventilation l0 f
Number of bedrooms Continuous ventilation 35
Section B
Ventilation Method
(Choose either balanced or exhaust only)
Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy EK Exhaust only
Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm
continuous ventlation rating by more than 100%.
Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed 1
continuous ventilation rating by more than 100°/x) 35
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
PAr 50i,lit_ #RDSVYLS5 UPPER rL prH o m 35 2D
At4AspwL vKS3 IMAW L&& 6th 5
t
AAlk&C AQW1 CAE~ 57
Section D
Controls
(Describe operation and control of the continuous ventilation)
INtt:L-AAi. LDN-ri ff U DU5 U tW T t LA T t0n1 GD mi-kDL
VJAU, 8VJI TA r-09- MAILIMUKk l16M1_tt_a7-lCJ GD,JT'eJXL
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 501.4.1)
Powered (determined from calculations from Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4. 1)
Other, describe: M I A
Location of duct or system ventilation make-up air: Determined from make-up air opening table
cfm 13Q Size and type (round, rectangular, flexor rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
D
Passive (see IFGC Appendix E, Worksheet E-1) Size and type it
Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional forms may. be downloaded and printed at:
i
i River Ridge Town Home Unit 8
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW
Rochester, MN 55901
n
RH-V' H V o A,
Prepared By:
Monday, September 09, 2013
i Rhvac - Residential & Light Commercial HVAC Loads Elite Softwar=DevemepnUt Minnesota Air River RidgBloomin ton MN 55438 Pro sect Re ort
mation
General Project Infor
Project Title: River Ridge Town Home Unit B
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
Client Address: 1244 60th Ave NW
Client City: Rochester, MN 55901
i Design Data
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
D Bulb Wet Bulb Rel u Dry Bulb Difference
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Figures
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Building Loads
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Btuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads z Elite Software Development, Inc,
Minnesota Air ' River Ridge Town Home Unit 8
I Bloomington, MN 55438 Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Indoor Indoor Grains
Input Data D Bulb Wet Bulb Rel.Hum D Bulb Difference
Winter: -20 0 30 72 34.40
Summer: 92 73 50 72 35.16
Duct Sizing Inputs
Main Trunk Run ut
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
LOutside Air Data
Winter Summer
Infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 12.517 Cu.ft. X 12.517 Cu.ft.
5,382 Cu.ft./hr 2,879 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 90 CFM 48 CFM
Total Building Ventilation: 0 CFM 0 CFM
--System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
C:\Users\Chad. MNAIR\Desktop\Offce Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
" Bloomington, MN 55438 Pace 4
Load Preview Report
Sys Sys Sys:
Has Net. Rec ft z: Sen. Lat. Netn Htg Cig Act; Duct
Scope AED Ton' Ton.. Iron Area: Gain Gain Gain Loss CFM. CFM CFM: Size
Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246
System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
i Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
1-Basement 543 1,117 328 1,645 7,498 100 52 100 1-6
2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5
3-Upper Floor 510 1,726 275 2,001 5,017 67 81 67 1-5
i
C:\Users\Chad.MNAIR\Desktop\Otfice Doc\Sales\river ridge unit B,rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomington MN 55438 Pa4e 5
Total Building Summa Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
Dbl Pane Lowe: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295
Low e, u-value 0.3, SHGC 0.33
7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195
or flutes, no screen, no coating, u-value 0.6, SHGC
0.65
11 P: Door=Metal - Polyurethane Core 42 1,120 0 378 378
15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23
foam board to 3', no framing, no interior finish, open
core, 8' floor depth
R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561
Insulation on Attic Floor (also use for Knee Walls and
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles
21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 20' wide
R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121
R-56.5 Over Open Crawl or Garage floor
Subtotals for structure: 9,573 0 3,308 3,308
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Ecursion: - - - - - -0 0 _1
_
_.86. --186-
Total Building Load Totals: 18,380 1,112 4,518 5,630
Check Figures
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Building Loads
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Btuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
I
I
i
C:\Users\Chad.MNAIRUDesktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013,1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomin ton, MN 55438 Page 6
System I Room Load Summary
I
Htg Min Run Run Cig Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh . CFM Size Vei Btuh Btuh CFM CFM
---Zone 1---
1 Basement 543 7,498 100 1-6 511 1,117 528 52 100
2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79
- 3_ Upper Floor _ 51:0.... _ 5,017 - - 67 1-5 493 1,726 . 275 - 81- 67.
System 1 total 1,563 18,380 246 4,518 1,112 212 246
System 1 Main Trunk Size: 7x7 in.
Velocity: 723 ft./min
Loss per 100 ft.: 0.157 in.wg
-Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons split Stuh Btuh Btuh
Net Required: 0.47 80%/20% 4,518 1,112 5,630
Recommended: 0.50 75%/25% 4,518 1,506 6,023
E ui ment Data
Heating System Cooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
I
C:\Users\Chad.MNAIR\Desktop\Off!ce Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM