Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
3178 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Dare Certlfkate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. Dwelling or Dwelling Urdt Clly SUPERIOR Mailing Address s o of the he D MItMfANIGAL !'1 Riverview Avenue Eagan Name of Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X passive (No Fran ) w o d w Active (With fan and monometer or y other system monitoring device) a v ~o u o w 3 ~ tj ~ o b A. Ga W V T o N W O ur N u g Insulation Location cx S z" . o b d r H 5 z w w a a Other Please Describe Here Below Entire Slab X Fotutdation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (lai Floor+) 19 X Type in location: interior exterior or integral wan 23 X Ceiling, flat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 9,138 Efficiency cooling load: Cfin's " round duct OR Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Ty e source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfins: Low: Hi : Other, describe: Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfim: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 87 " metal duct Date. 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type A Unit Project Address 2: JI7' ?,,I YOrV te4AAA" Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1363 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3 Ventilation : Exhaust Total Ventilation Capacity : 60 cfm. Minimum Continuous Ventilation :60cfm. Ventilation: e=xhaust: 60 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler. Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 131 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches AS~Gp~~,~ ic-pltr ~Zoapn 61Zc 7 K 13 Y. e= 72-8 F-73 Applicant Name (print): 5„P ,flR.mEcrr~a, /~Z f, Signature/Date: fi~lr` 9 '13 _ Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address 3l7 i tj U Date Q HVAC U PW.J bF_ LIDhIpAt4lo a miryr(F,rag Y~ompleted Contractor B (_J~J Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including 2 Basement - finished or unfinished) 13 63 Total required ventilation ~I J Number of bedrooms Continuous ventilation `i Section B Ventilation Method (Choose either balanced or exhaust only) Q Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low cfm: High cfm: I Continuous fan rating in cfm (capacity must not exceed I continuous ventilation rating b more than 100% `t Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation aro 5 n i& t FvoU S9 PFE2 A fti v. ALWISOK'It. K o 0 75 Section D Controls Describe operation and control of the continuous ventilation TWr 66 2k t. CDIj'f' I N LA US VEIJ-r i AT oyJ M v t r I 'I Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4. 1) Other, describe: N A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm 1 15 Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: River Ridge Town Home Unit A HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 a no= Sill Prepared By: Monday, September 09, 2013 Rhvac - Residential & Light Commercial HVAC Loads - Elite Software Development, Inc. Minnesota Air 1 River Ridge Town Home Unit A Bioomin ton MN 5438 P 2 Project Report General Project Information Project Title: River Ridge Town Home Unit A Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Desi n Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Drv Bulb Wet Buib Rei.Hum Drv Bulb Qft== Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 71 LCheck Figures Total Building Supply CFM: 382 CFM Per Square ft.. 0.280 Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Building Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013,11:55 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Nome Unit A Bloomington MN 55438 P ae 3~ Miscellaneous Report [In tem 1 Outdoor Outdoor Indoor indoor Grains u B 72 Differenc ut Da fa. Bulb Wet Bulb Rel.H r n Winter: -20 0 0 34.40 Summer: 92 73 50 72 35.16 71 Duct Sizing Inputs Mein Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 11.038 Cu.ft. X 11.038 Cu.ft. 4,746 Cu.ft./hr 2,539 Cu.ft./hr 7 Total Building Infiltration: 9 CFM 42 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) I I C:\Users\Chad.MNAiR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac - Residential 8 Light Commercial HVAC Loads Elite Software Development, Inc, . Minnesota Air River Ridge Town Home Uanit 4 Bloomington, N 55436 i Load Preview Re ort Sys; . Sys Sys: Has' Net Rec" tt2i Sen Let! Net Sen lytg; Cig Act; Duct Size AED Ton:. Ton; 1Ton Area; Gain; Gaih Gain:: Loss: Scope t CFM CFM, CFI Building 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9 Zone 1 1,364 8,157 981 9,138 22,714 304 382 382 9x9 1-Basement 104 655 206 861 5,392 72 31 31 1-4 2-Main Floor 630 3,535 399 3,934 8,797 118 166 166 2-5 3-2nd Floor 630 3,967 376 4,343 8,525 114 186 18 2-6 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM I Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit A 5 Bloomington. MN 55438 P e Total Buildin Summa Loads Component Area Sen Lat Sen Total Description . uan Loss, Gain Gain ain Dbl Pane Low e: Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914 Low e, u-value 0.3, SHGC 0.33 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10sffc-8: Wall-Basement, concrete block wall, R-10 123.5 537 0 26 26 foam board to floor, no framing, no interior finish, filled core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090 15a-1-sffc-8: Wall- 76 421 0 22 22 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 258 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20' wide 22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0 0 0 covers slab edge, turns under slab and extends 4' horizontally, any floor cover, R-10 insulation, passive, heavy dry or light wet soil R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131 R-56.5 Over Open Crawl or Garage Floor Subtotals for structure: 14,947 0 7,254 7,254 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 79, Summer CFM: 42 7,767 981 903 1,884 Ventilation: Winter CFM:.0, Summer_CFM:.O-.._._ _ _..........._0--. _ . - Total Building Load Totals: 22,714 981 8,157 9,138 Check Fi ures Total Building Supply CFM: 382 CFM Per Square ft.: 0.280 Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505 Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0 Buildin Loads Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH Total Sensible Gain: 8,157 Btuh 89 % Total Latent Gain: 981 Btuh 11 % Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent) 0.91 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc Minnesota Air River Ridge Town Home Unit A Bloomington MN 55438 Page 61 System 1 Room Load Summa Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Senn Lat Clg Sys I No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 104 5,392 72 1-4 352 655 206 31 31 2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166 _3 2nd Floor. 630 8.525 .114 . .2-6 . 473........3,967.....376: 186....... 1.$6.. System 1 total 1,364 22,714 304 8,157 981 382 382 System 1 Main Trunk Size: 9x9 in. Velocity: 679 ft./min Loss per 100 ft.: 0.117 in.wg Cooliin System Summa Cooling Sensible/Latent Sensible Latent ' Total Tons Split : Bt h Btuh" 5tuh Net Required: 0.76 89%/11% 8,157 981 9,138 Recommended: 0.91 75%/25% 8,157 2,719 10,876 Equipment Data Heating System Cooling System Type: Model Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM