3180 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate
Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certlrleate Posted
building. The certificate shall be completed by the builder and shall list information and values of components
listed in Table 8. SUPERIOR
Malting Address ofthe ofihe Dwelling or Dwelling Unit CRY ti -3 W Riverview Avenue Ea an
Name of Residential Contractor MN Licerrre Number
Superior Companies of Minnesota Inc M64551
THERMAL ENVELOPE RADON SYSTEM
Type: Check All That Apply X Passive (No Fan )
o
c
T _ Active (With fan and manometer or
t r other system monitoring device)
_ b 0
c
o a o y~ U c b
< 05 M 6 o
O vi of O
Insulation Location c b v g
m a c v fl Fd d o n
F° 4- z w w w° w° a s Outer Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or Integral
Perimeter of Slab on Grade 10 X
Rini Joist (Foundation) 19 X Type in location: interior exterior or integral
Rim Joist (1st Floor) 19 X Type in location: interior exterior or integral
Wall 23 X
Ceiling, flat 49 X
Ceiling, vaulted X
Bay Windows or cantilevered areas 56.5 X X
Bonus room over garage 56.5 X X
Describe other insulated areas
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.33 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
FuelType NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A04OE14 GPD-40 24AC6318A30 Describe:
Input in 40,000 Capacity in 40 Output in 1.5 Other, describe:
Rating or Size BTUs: Gallons: Tons:
Heat Loss: 18,380 Heat Gain: 5,630 Location ofduct or system:
Structure's Calculated
AFUE or 96.5 SEER: 15.5
HSPF%
Calculated 5,630
Efficiency cooling load Cfnfs
" round duct OR
Mechanical Ventilation System " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfins: Low: High: Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfms:
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfms: 44 6 " round duct OR
Total ventilation (intermittent + continuous) rate in cfrns: 87 " metal duct
Date: 7/112013 Revision Date: 711/2013 New Construction
Site Information
Address 1: Type B Unit Project
Address 2:,31,80 1,t\(e(-Vim f{v~Lke_, Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph:
Address 1: 1244 60th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square Feet: 1200 sq. ft. Avg: Ceiling Ht: 8 ft. Number of Bedrooms: 2
Ventilation : Exhaust
Total Ventilation Capacity : 45 cfm.
Minimum Continuous Ventilation :45cfm.
Ventilation: Exhaust: 45 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler. Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 140
Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches
Combustion Alr
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
Applicant Name (print):S,~P~2~ M - r~~~~,r ~6. Signature/Date: 9-~ ->3
I
Code Official (print): Signature/Date:
C 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I
2009 Mechanical & Energy Code- Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application of a mechanical permit for new construction
Site address ziz> w
(W A ub Date 9.9.
HVAC uPl'luoil . I;DMPANi ✓z &f MIfAt4e_-wrA C mpieted _h JD~
Contractor U. NAP6111011 PA9r_MAt4tt_4b T' By
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including ran ~`7
Basement - finished or unfinished) 12DD Total required ventilation A
Number of bedrooms 2 Continuous ventilation 35
Section B
Ventilation Method
(Choose either balanced orexhaust only)
Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy L5 Exhaust only
Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm
continuous ventilation ratio by more than 100%.
Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating b more than 100% 35
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
t A it- #E 0Gv tApp n
fwASyt(IL # MRIM
Ruls~ Iran 7~~rLl C ~1
Section D
Controls
(Describe operation and control of the continuous ventilation
INt AL rrfttAous YI NT ILATIW r-om-rkot -
WA 8WI-MA POP- AMMuM 11 1J t R'( o
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 501.4.1)
Powered {determined from calculations from Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4, 1)
Other, describe: N I A
Location of duct or system ventilation make-up air: Determined from make-up air opening table
Cfm 13Q Size and type (round, rectangular, flex or rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
Passive (see IFGC Appendix E, Worksheet E-1) Size and type it
I I Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional fortes may be downloaded and printed at:
River Ridge Town Home Unit 8
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW
Rochester, MN 55901
RHVNt"A,;%wo, HV.AC LoA-Ds
Prepared By:
Monday, September 09, 2013
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomin t n MN 55438 Page
Proiect Report
General Project Information
Project Title: River Ridge Town Home Unit B
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
Client Address: 1244 60th Ave NW
Client City: Rochester, MN 55901
Desi n Da a
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor:. 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
rBulb Wet Bulb Rel.Hum QprBulb Difference
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Fi ure§
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Building Loads .
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Btuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAIR\Desktop\Offlce Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomington. MN 55438 e
Miscellaneous Report
System 1 Outdoor Outdoor Indoor. Indoor Grains
Input Data D Bulb Wet Bulb Rel.Hum. Dr Bulb Difference
Winter: -20 0 30 72 34.40
Summer: 92 73 50 72 35.16
Duct Sizing Inputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 12.517 Cu.ft. X_ 12.517 Cu.ft.
5,382 Cu.ft./hr 2,879 Cu.ft./hr
X 0.0167 X.0.01 7
Total Building Infiltration: 90 CFM 48 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomington MN 55438 Paae 4
Load Preview Re ort
Has Net Rec;: 2: 1 Sen Lat Net Sen Sysi Sys' Sys Duct
Htg1 Cig;. Act.
Scope AED Ton. Ton /Ton; Area' Gain! Gairr' Gain Loss CFM CFM CFMSiz
_
Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246
System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
1-Basement 543 1,117 528 1,645 7,498 100 52 100 1-6
2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5
3-Upper Floor 510 1,726 275 2,001 5,017 67 81 7 1-5
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. jk~ Minnesota Air River Ridge Town Home Unit B
Bloomington. MN 543 Paae 5
Total Building Summa Loads
Component Area. Sen Lat Sen Total
Description Qua Loss Gain Gin Gain
Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295
Low e, u-value 0.3, SHGC 0.33
7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195
or flutes, no screen, no coating, u-value 0.6, SHGC
0.65
11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378
15A-1 Os3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23
foam board to 3', no framing, no interior finish, open
core, 8' floor depth
R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561
Insulation on Attic Floor (also use for Knee Walls and
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles
21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 20' wide
R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121
_ R-56,5 Over Open Crawl or Garage
Subtotals for structure: 9,573 0 3,308 3,308
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Excursion: 0 0 186 186
Total Building Load Totals: 18,380 1,112 4,518 5,630
Check Fi ures
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Building Loads
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Btuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Stuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes , .
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bioomin ton MN 55438 Pa
System 1 Room Load Summa
Htg Min Run Ruh Clg Clg Min Act
L Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Stuh CFM CFM
---Zone 1---
1 Basement 543 7,498 100 1-6 511 1,117 528 52 100
2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79
_3 ...Vpper-Floor. ....510 5,017 ....67.......... -5.. .:..493 1 ,.726 275......__. 81....-_..... 67_
System 1 total 1,563 18,380 246 4,518 1,112 212 246
System 1 Main Trunk Size: 7x7 in.
Velocity: 723 ft./min
Loss per 100 ft.: 0.157 in.wg
Coolln System Summa
Cooling Sensible/Latent Sensible " . Latent Total
Tons Split 8tuh StUl1 Btuh
Net Required: 0.47 80%/20% 4,518 1,112 5,630
Recommended: 0.50 75%/25% 4,518 1,506 6,023
Equipment Data
Heating System Cooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
f