Loading...
3184 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certlileate Posted building. The certificate shall be completed by the builder and shall list information and values of componentsy listed in Table N l 101.8. SUPERIOR Mailing Address of the Dwelling or Dwelling Unit City Riverview Avenue Ea an %Name of Residential Contractor - MN License Nnrnher ,Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) o ° ~ c o Active (With fan and manometer or Ey a other system monitoring device) 0 a ~ 2 U , o b frs v U "e b 15 Insulation Location ° z v " w a 7 ° to E ti o H a z w w Outer Please Describe Here Below Entire Slab X Foundation Wail 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1st Floor) 19 X Type in location: interior exterior or integral Wall 23 X Ceiling, flat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Selecta Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 18,380 Heat Gain: 5,630 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPFa/o Calculated 5,630 Efficient cooling load: Cm's round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a type source heat pump with gas back-up furnace): Not required per mech. code Select T}pe X Passive Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity nr cfins: Low: Hi Location of duct or system: Continuous exhausting fan(s) rated capacity in cf ms: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 87 .metal duct Date: 7/112013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type B Unit Project Address 2: i,IVef'Vid.L0 A~jenu~ Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City. Rochester State: MN Zip Code: 55901 House Details Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 140 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches metcfmf. ICIi t- Y-2> $9ie F-13 Applicant Name (print):S,Ipi~2razMP-►nr mgL-,fi? sSignature/Date: Code Official (print): Signature/Date. 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address Date HVAC U?Sj4D9. COMPAt4I M K MrrtrbES,5-rA C mpieted „h Contractor By Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including ~f ,ter, 1 ~S Basement - finished or unfinished) 12.DO Total required ventilation t0 _I Number of bedrooms Continuous ventilation 35 Section B Ventilation Method (Choose either balanced or exhaust only) Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Z Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation ratio b more than 100°/x. Low cfm: I I High cfm: Continuous fan rating in cfm (capacity must not exceed continuous ventilation ratio by more than 100%) ~s Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation # n -so P" v 1o IG T ErJ Section D Controls Describe operation and control of the continuous ventilation), INna,aat., WN-n(ivtou ViNTILATI tJ CDNT2DL WALL 3wii-c.A POLL MWMu V9M t Arlo T Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4.1) Other, describe: N I A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm ~Q Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type n p Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit (or new construction. Additional forms maybe downloaded and printed at: River Ridge Town Home Unit 8 HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 H T ! R - C HVAC ;V.,A Prepared By: Monday, September 09, 2013 i Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B loomin ton MN 55438 Pro'ect Report General Pro'ect Information Project Title: River Ridge Town Home Unit B Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Design Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb t Bulb Rel.Hum U Bulb Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Fi ures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Building Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Stuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington-MN 543 P e Miscellaneous Report Systern 1 Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel Hum Dry Bulb Difference Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg.1100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in, 0 in. Outside Air Data Winter Summer_ Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 12.517 Cu.ft. X 12.517 Cu.ft. 5,382 Cu.ft./hr 2,879 Cu.ft./hr X 0,0167 X 0.0167 Total Building Infiltration: 90 CFM 48 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Hom~Pa Unit B I C Bloomin ton MN 55438 e 4' Load Preview Report Sys: Sys' Sys Has': Net Rec V Sen Lat: Net Sen Ht9 CIg Act, Duct Scope AED~ Ton Ton:; /Ton Area 'Gain; Gain! Gain Loss; ; Size CFM: CFM;. CFM; . Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 1-Basement 543 1,117 528 1,645 7,498 100 52 100 1.6 2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5 3-Upper Floor 510 1,726, 275 2,001 5,017 67 81 67 1-5 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington, M 56438 9. 21~ Page 51 Total Building Summa Loads Component Area. Sen Let Sen Total Description Qu n La Gain Gin Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295 Low e, u-value 0.3, SHGC 0.33 7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195 or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23 foam board to 3', no framing, no interior finish, open core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121 R-56.5 Over Open Crawl or Garage Floori____v,_.__ Subtotals for structure: 9,573 0 3,308 3,308 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 _AED_Excursion---------------- - . -.....--.-.0................__186........ .__..g6. Total Building Load Totals: 18,380 1,112 4,518 5,630 Check Fi ures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (W) of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Buildin 'Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I I C:\Users\Chad.MNAIR\Desktcp\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inca Minnesota Air River Ridge Town Home Unit B Bloo in ton . MN 5438 Pa 6 system I Room Load Summa Htg Min Run Run Clg Cig Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM r ---Zone 1--- 1 Basement 543 7,498 100 1-6 511 1,117 528 52 100 2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79 - - 3 Upper Floor.. - _.....510....-_..5,017....-.... - -._6.7 .............._.1-5 .493....- 1 726........._275............... 81.__.........._..67... System 1 total 1,563 18,380 246 4,518 1,112 212 246 System 1 Main Trunk Size: 7x7 in. Velocity: 723 ft./min Loss per 100 ft.: 0.157 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons split Btuh Btu h Net Required: 0.47 80%/20% 4,518 1,112 5,630 Recommended: 0.50 75%/25% 4,518 1,506 6,023 Equipment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM