3168 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate Certificate Posted Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the r building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 10 1. 8. SUPERIOR Mailing Address s of o[ the the Dwelling or Dwelling Unit city MfetRA1VICAL Riverview Avenue Eagan ` Name of Residential Contractor MN License Number ,Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) w o m c Active (With fan and manometer or F' a other system monitoring device ) o a ~ ~ U o zs d v C~ v ~ ~ Ga ~ of O ai N O V iz V u g w Insulation Location > o z t9 o 00 m ;ci ti C a1 oa F a'~ z Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Stab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1st Floor) 19 X Type in location: interior exterior or integral Wall 23 X Ceiling, fiat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X 4+ X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors eating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 111-value MECHANICAL SYSTEMS Make-up Air Select a7);pe Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 18,380 Heat Gain: 5,630 Location of duct or system: Structure's Calculated ARM or 96.5 SEER: 15.5 HSPF% Calculated 5,630 Etficlenc cooling load: Cftn's round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity in cfrns: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), describe: Cfin's Capacity continuous ventilation rate in clins: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 87 " metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type B Unit Project Address 2. 01&e Z\(e.r°vid wJ A~j~Lkp , Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 140 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches me 3a)GH~ t 5~zr:: x8= 89~ F;3 Applicant Name (print):Signature/Date: ->3 Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page l 2009 Mechanical' & Energy Corm - Ventilation, !Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address, 1 j pate J {Z4QE -tr fLi)-) ~ s1t Cis . i4 HV .C -fit ~~aC,9 i~eJpANieS arrttSGobSA mpleted _.=t ottractor ~s °l!~R lt?C fd$ r By Poo i_~O z p Section A Ventilation Quantity (Det°rn7ine quantity by using Tattle N1104.2 qr Eauatian 11-1) S_,uare feet (Conditioner a Ga including Basement -fnished7. unfinished) I L1.rr/ Total required ventilation M T tt~ Continuous ventilat,cn Nunber of bedroarrrs~ section& Ventilation Method (Choose eftt:er balanced or exhaust only) E] Ba-cmced HRV (He r Recover)Ventilator} or ERV (Energy ( Exhaust only :pe cvery VennP +or)- e r- of unit r r iou must not exceed Continuous fan rating cfrn cor "Inuous ventilation rating by more than 100%- a.crr High alit: Continuous fan rating in cfm (capacity rust not exceed n conf;nuous ventilation rating by more Phart 100%) Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation iPRI r1A`P?k tl»gv~_S 41. A P (L _1 +IEt. Arw Room y _ _ &a A As~N 1f I FVQSvKS l ~l l +r t AT a n>1 o f A 1 ~G rw~ l6 -r c~-fit l' Section D 1 Controls (Describe operation, and control of the continuous ventilation) ngI- it.. Srr~iNOuS Uf=nlT{1 Ai z rJ Cc?ns_~.201 ~_lilAl 3WITcEA F-Of- mi zki huhA gEtKt`iLpi"to~. 1TPtx S~cflon E { Make-up air for ventilation passive (determined from calculations from Table 501.4.1) Powered (determined frorn caicu<ations from Table 501A,1) Interlocked with exhaust device (determined from calculation from Table 50; 4.1) Other, describe- Location of duct or System ventilation make-up air; Determined from make-up air opening table Cfrn~ Size and type (round rectangular, flex or ri,id) Section F Make-up air for combustion or cod (Ng atr- spf)eric o pcw r ve^ted apps r„as) Passive (see FGC Appendix E Arorh heet E-1) ~ Size and type totes: ir~;tructiors and example forms are available at the Building Safely websit2 and at lire nuiidinc Safety offce. This form must be - suto:nitted at the time of application of a mechanical permit for new construction, Additional forms maybe downloaded and printed at River Ridge Town Home Unit B HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 f(tw a 11 1 E: -S' I D a- 14* r W. V , " CHVAC iwko - Prepared By: Monday, September 09, 2013 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Blooming a e on MN 55438 Project Report, General Proiect Information Project Title: River Ridge Town Home Unit B Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Desi n Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Di~f B lb Wet Bulb eR I.Hum Dry Bulb Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 I Check Figures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Buildin Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington MN 55438 Miscellaneous Report System 1 Outdoor Outdoor Indoor Indoor Grains Input Data D Bulb Wet Bulb Rel.Hum. D Bulb Differen e Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 Duct Sizih~ Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft, 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 12.517 Cu.ft. X_ 12,517 Cu.ft. 5,382 Cu.ft./hr 2,879 Cu.ft./hr X 0.4167 X 0.4167 Total Building Infiltration: 90 CFM 48 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington, MN 55438 Page 4 Load Preview Report Has Net' Rea fL2; Sen Lat' Net; Sen yts' Cis, Act Duct Scope : AED: Ton Tom /Ton; Area; Gain, Gain; Gain Loss 9; g Size CFM CFM. CFM i Building 0,47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 1-Basement 543 1,117 528 1,645 7,498 100 52 100 1-6 2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1.5 3-Upper Floor 510 1,726 275 2,001 5,017 67 81 67 1-5 C:\Users\Chad.MNAIR\Desktop\Cffice Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, inc. Minnesota Air River Ridge Town Home Unit B Bloominoton MN 55438 Pa4e $ Total Building Summary Loads I Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295 Low e, u-value 0.3, SHGC 0.33 7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195 or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23 foam board to 3', no framing, no interior finish, open core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121 _ R-56.5 Over Open Crawl or Garage Floor._-___~____ Subtotals for structure: _ 9,573 0 3,308 3,308 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 4 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion_----....-- . - _ ----__..:...186........._.......186_ Total Building Load Totals: 18,380 1,112 4,518 5,630 Check Figures Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 Buildinq Loads - Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Stuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM i Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit B Bloomington, MN 55438 pane 6 S stem 7 Room Load Summa Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Cig Sys i No Name SF Stuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Basement 543 7,498 100 1-6 511 1,117 528 52 100 2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79 _3. Upper Floor_ 510....., 5,017 6.7... 1-5.........493.- 1,726. 275.......... 81._.._ 67 System 1 total 1,563 18,380 246 4,518 1,112 212 246 System 1 Main Trunk Size: 7x7 in. Velocity: 723 ft./min Loss per 100 ft.: 0.157 in.wg Cooling S stem Summa Cooling Sensible/Latent Sensible Latent Total Tons split B u to tuh Net Required: 0.47 80%/20% 4,518 1,112 5,630 Recommended: 0.50 75%/25% 4,518 1,506 6,023 [Equipment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM