3170 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted
building The certificate shall be completed by the builder and shall list information and values of components
listed in Table N1101.8.
Mailing Address of the Dwelling or Dwelling Unit City
MECHANICAL
3170 Riverview Avenue Eagan
Name of Residential Contractor MN License Number
Superior Companies of Minnesota Inc MB4551
THERMAL ENVELOPE RADON SYSTEM
Type: Check All That Apply X Passive (No Fan }
o v
Ii Active (With fan and monometer or
F~ other system monitoring device
a d o°
`y3 U ~ 'o v
~ W ~ m U ~ ro 'c'c,
O o N O A U
Insulation Location ? z g v 0O ' w W A
N
4 z w w w° w° :2 a i~ Other Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or integral
Perimeter of Slab on Grade 10 X
Rim Joist (Foundation) 19 X Type in location: interior exterior or Integral
Rim Joist (1" Floor) 19 X Type in location: interior exterior or integral
Wall 23 X
Ceiling, flat 49 X
Ceiling, vaulted X
Bay Windows or cantilevered areas 56.5 X X
Bonus room over garage 56.5 X X
Describe other insulated areas
Windows & Doors Heating or Coolin Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 Not a licable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.33 R-value
MECHANICAL SYSTEMS Make-up Air Select aType
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A040E14 GPD-40 24ACB318A30 Describe:
Input in 40,000 Capacity in 40 Output in 1.5 Other, describe:
Rating or Size BTUS: Gallons: Tons:
Heat Loss: 18,380 Heat Gain: 5,630 Location of duct or system:
Structure's Calculated
AFUE or 96.5 sEER: 15.5
HSPFeru
Calculated 5,630
Efficient cooling load: Cfin's
round duct OR
Mechanical Ventilation System " metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a T pe
source heat pump with gas back-up fiunace): Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in efms: Low: Hi : Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfms: Low; High: Location of duct or system:
Continuous exhausting fan(s) rated capacity in cfins:
Location of fan(s), describe: Cfm's
Capacity continuous ventilation rate in cfins: 44 6 " round duct OR
E Total ventilation (intermittent + continuous) rate in cfins: $T " metal duct
Date: 711/2013 Revision Date: 7/1/2013 New Construction
Site Information
Address 1: Type B Unit Project
Address 2: J/7P Qi ferv1di-J AU~Lke_, Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph:
Address 1: 1244 60th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2
Ventilation : Exhaust
Total Ventilation Capacity : 45 cfm.
Minimum Continuous Ventilation :45cfm.
Ventilation: Exhaust: 45 cfm.
Combustion Appliance
Water Heater: Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler: Direct Vent/Seated Combustion Input BTUs: 40,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 140
Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
mcCIIAa)c"'~ y SI ze, : -7 $-/to Y_ a9to F-3
Applicant Name (print): S,~Pc2~a~r~~h~~~~9~~~ SSignature/Date: 9_ >3
Code Official (print): Signature/Date:
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page 1
2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application of a mechanical permit for new construction
Site address ' Date
HVAC
r
By
Contractor uPt:RdDdi. bDmPAtgiEz o6MrNt4,t.S67A C rlpieted pDh JorI
~(jJ f iJ
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including
Basement - finished or unfinished) Total required ventilation 7
Number of bedrooms Z Continuous ventilation 35
Section B
Ventilation Method
(Choose either balanced or exhaust only)
Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy [ Exhaust only
Recovery Ventilator) - dm of unit in low must not exceed Continuous fan rating cfm
continuous ventilation ratio by more than 100%.
Low cfm: High cfm: Continuous fan rating in cfm (capacity must not exceed 35
continuous ventilation ratio b more than 100%
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
AtUr,oka- # t(D$V S3 IAPPE' b Uom .3V (3 A 0 so
iZ W'e ADDIO 'rcAg,4
Section D
Controls
Describe operation and control of the continuous ventilation)
INTgO.AL LDWr t'1m ou5 VKNTiLA T 10tJ CDN'T2DL
WAIL 5w,
POPL AMMU W6M'rtLWr a t047[7eXiI_
TCA
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 501.4.1)
Powered (determined from cak;ulatlons ftom Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4. 1)
Other, describe: N' A
Location of duct or system ventilation make-up air; Determined from make-up air opening table
Cfm i 3Q Size and type (round, rectangular, flex or rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
Passive (see IFGC Appendix E, Worksheet E-1) Size and type n
Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at:
River Ridge Town Home Unit 8
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW
Rochester, MN 55901
i.
- 9 ,
e
a
RH-IV.
Prepared By:
Monday, September 09, 2013
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloomin on MN 55438 Page 2
Project Report
General Proiect Information
Project Title: River Ridge Town Home Unit B
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
Client Address: 1244 60th Ave NW
Client City: Rochester, MN 55901
Desi n Data
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hunn Dry Bulb Difference
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Fi ures
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft3) of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Building Loads
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Btuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, [tic.
Minnesota Air River Ridge Town Home Unit B
Blo min on MN 55438 Page I
Miscellaneous Report
System 1 Outdoor Outdoor Indoor. Indoor Grains
Input Data. D Bulb Wet Bulb Rel.Hum D Bulb ` Difference
Winter: -20 0 30 72 34.40
Summer: 92 73 50 72 35.16
Duct Sizing Inputs
Main Trunk Runoy~t .
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 12.517 Cu.ft. X 12.517 Cu.ft.
5,382 Cu.ft./hr 2,879 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 90 CFM 48 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
i
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bioomin ton MN 55438 Page 4
Load Preview Report
2 i Sys, Sys( Sys;
Has: Net Rec tt Sen; Lat Net Sen Ht CI ActDuct
Scope AEDTon! Ton:: /Ton: Area; Gain' Gaini Gain. Loss g 9; Size
CFM CFM CFM
Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246
System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7
1-Basement 543 1,117 528 1,645 7,498 100 52 100 1-6
2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1-5
3-Upper Floor 510 1,726 275 2,001, 5,017 67 81 67 1-5
C,\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.,
Minnesota Air River Ridge Town Home Unit B I
Bloomington MN 55438 Page 5
Total Building Summa Loads
Component Area Sen Lat Sen Total
Description Quan Los Gain G in Gain
Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295
Low e, u-value 0.3, SHGC 0.33
7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195
or flutes, no screen, no coating, u-value 0.6, SHGC
0.65
11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378
15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23
foam board to 3', no framing, no interior finish, open
core, 8' floor depth
R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561
Insulation on Attic Floor (also use for Knee Walls and
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles
21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 20' wide
R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121
_ R-56.5 Over Open Crawl or Garage Floor___`_.v._ -
for structure: _ 9,573 0 3,308 3,308
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
_AED.Excursion;---------------- - . 186---_..----..... 186.
Total Building Load Totals: 18,380 1,112 4,518 5,630
Check Figures
Total Building Supply CFM: 246 CFM Per Square ft.: 0.157
Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114
Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1
Buildin "Loads
Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH
Total Sensible Gain: 4,518 Stuh 80 %
Total Latent Gain: 1,112 Btuh 20 %
Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent)
0.50 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\Chad.MNAiR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM
Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit B
Bloominoton. MN 55438 Page 6
System I Room Load Summa
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Basement 543 7,498 100 1-6 511 1,117 528 52 100
2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79
_..3..~Jpper_Floor . ....510.......5,017 _67.. 1-5 .....493_._..__ 1,726....._..275....... 81. 67..
System 1 total 1,563 18,380 246 4,518 1,112 212 246
System 1 Main Trunk Size: 7x7 in.
Velocity: 723 ft./min
Loss per 100 ft.: 0.157 in.wg
Cooling System Summa
Cooling Sensible/Latent Sensible Latent Total
Tons Spilt Btuh. Bt h Bt h
Net Required: 0.47 80%/20% 4,518 1,112 5,630
Recommended: 0.50 75%/25% 4,518 1,506 6,023
Equipment Data
Heating System Cooling System
Type:
Model
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM