Loading...
3172 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per NI 101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certificate Posted building. The certificate shall be completed by the builder and shall list information and values of components listed in Table NI 101.8. SUPERIOR Mailing Address of the Dwelling or Dwelling Unit City %•,.,.AIr, MECHANICAL .3119. Riverview Avenue Eagan Name or Residential Contractor MN License Number Superior Companies of Minnesota Inc M134551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) w 0 0 Active (With fan and monometer or Er other system monitoring device) o a Mo d q ct iii W b U b p *6 0 2l 0 Insulation Location c z 9 a U 8' w n' ~ o ~o m ~ ;o b p N O A p ~ r.9 0a 00 H 4 z is. w w wO 'r2 ;i~ Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X Type in location: interior exterior or integral Rim Joist (1st Floori•) 19 X Type in location: interior exterior or integral wan 23 X Ceiling, flat 49 X Ceg, vaulted X X Bay Windows or cantilevered areas 56.5 X tff Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors Heating or Coolin Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gahi Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required ermech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 18,380 Heat Gain: 55,630 Location of duct or system: r Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 5,630 Efficiency cooling load: Cfnt's " round duct OR Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfins: Low: High: Other, describe: Energy Recover Ventilator (ERV) Capacity in cfftis: Low; High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfins: Location of fan(s), describe: Cfm's Capacity continuous ventilation rate in cfms: 44 6 " round duct OR Total ventilation (intennittent + continuous) rate in cfms: 87 "metal duct Date: 7/1/2013 Revision Date: 7/1/2013 New Construction Site Information Address 1: Type B Unit Project Address 2:3/72 iZIVCrViduJ /{~~L.Lt, Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 1200 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 40,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 140 Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches mcCfmt►ic-,4)t_ 5, Z.6: 7)L-/lo Y.- 0, a91. F-3 Applicant Name (print):SAPc2~ sSignature/Date: ,!~-9-)3_ Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of~yapplication of a mechanical permit for new construction Site address 2 21v~1 A ue.Y1(, b Date -41 HVAC uPt 144 L MPANIE6 K MrPWO--6-M C mpleted G Contractor By a 11J Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including o Basement - finished or unfinished) i 2DD Total required ventilation Number of bedrooms 2 Continuous ventilation Section B Ventilation Method (Choose either balanced or exhaust only) Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation rating by more than 100%. Low m: High cfm: Continuous fan rating in cfm (capacity must not exceed 35 continuous ventilation rating by more than 100% Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation PA AnQ 9 l~1 IZ K&e AOD.D >G7Cdkfi.4 10 Section D Controls Describe operation and control of the continuous ventilation SNTEL-44L LL1N-r0tA0Lt6 99NTtLATrot4 WN-rg-O - ALL WI r-012- MAILIMU 11 'i't Tt Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4, 1) Other, describe: N I A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm Ia Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type in a f~ LidL Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may. be downloaded and printed at: I i I River Ridge Town Home Unit 8 HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 i i I FZj iDiwN" LAj.E HVAC oAn I i I i i I i Prepared By: I i i Monday, September 09, 2013 i i i Rhva R ntial 8. Light Commercial HVAC Loads Elite Software Development, inc. Minnesota Air River Ridge Town Home Unit B Bloomington, MN 55438 P e 2 I Project Report 'General Project Information _ Project Title: River Ridge Town Home Unit B Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 t DesianData Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains DU Bulb Wet Bulb Rgl.Hum Qry Bulb. Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 j Check Figures _ Total Building Supply CFM: 246 CFM Per Square ft.: 0.157 Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (ft') of Cond. Space: 13,553 Air Turnover Rate (per hour): 1.1 :Building Loads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) Notes _ Calculations are based on 8th edition of ACCA Manual J, All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ! I I I I ! I C:\Users\Chad.MNAIR\Desktop\Ofi'ice Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rh av - Residential & Light Commercial HVAC Loads Elite Software Development, Inc Minnesota Air River Ridge Town Home Unit B I Bloomington, MN. 55438 Pace 31 Miscellaneous Report E S s 1 Outdoor Outdoor Indoor Indoor Grains i i Y Bulb Rel.Hum Dry :Bulb Difference Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 j ,Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. l Outside kr Data' Winter Summer - Infiltration: 0.430 AC/hr 0.230 AC/hr { Above Grade Volume: X 12,517 Cu.ft. X_ 12,517 Cu.ft. 5,382 Cu.ft./hr 2,879 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 90 CFM 48 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) I Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) I { C I I j I I I { I I C:\Users\Chad.MNAiR\Desktop\Office Doc\Sales\rver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM j Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Ind. Minnesota Air River Ridge Town Home Unit B Bloomin tog n.. MN 55438 _ Page 41 i Load Preview Report Sys' Sys Sys Has Net Rec ft. Sen Lat Net Sen Duct H, C~ Act, Scope AED' Ton Tom' /Ton Area Gain Gain Gain Loss GF M- CFM CFM Size Building 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 System 1 No 0.47 0.50 3,114 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 Zone 1 1,563 4,518 1,112 5,630 18,380 246 212 246 7x7 1-Basement 543 1,117 528 1,645 7,498 100 52 100 1-6 2-Main Floor 510 1,675 309 1,984 5,865 79 78 79 1.5 3-Upper Floor 510 1,726 275 2,001 5,017 67 81 67 1-5 i i I i 1 i i i i I ~ i i I i I C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\river ridge unit B.rhv Monday, September 09, 2013, 1:04 PM Rhvac - Residential & ,Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit 8 j Bloomington, MN 55438 Page 5 i Tofa/ Building Summary Loads component Area Sen Let Sen Total . Description _ Quan Loss Gain. Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 70 1,932 0 1,295 1,295 Low e, u-value 0.3, SHGC 0.33 7A-1: Glazing-Glass or plastic block, smooth or wide ribs 8 442 0 195 195 i or flutes, no screen, no coating, u-value 0.6, SHGC 0.65 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 15A-10s3oc-8: Wall-Basement, concrete block wall, R-10 139.5 885 0 23 23 foam board to 3', no framing, no interior finish, open core, 8' floor depth R-23 wall: Wall-Frame, , R-23 insulated wall 835.5 3,336 0 735 735 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 510 938 0 561 561 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark Asphalt Shingles 21 B-20: Floor-Basement, Concrete slab, any thickness, 2 100.8 176 0 0 0 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide R-56.5: Floor-Over open crawl space or garage, Custom, 449.5 744 0 121 121 R-56.5 Over Open Crawl or Garage Floor - Subtotals for structure: 9,573 0 3,308 3,308 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 90, Summer CFM: 48 8,807 1,112 1,024 2,136 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: .0 0 186 186 Total Building Load Totals: 18,380 1,112 4,518 5,630 Check Figures Total Building SupplyCFM: 246 CFM Per Square ft.: 0.157 I Square ft. of Room Area: 1,563 Square ft. Per Ton: 3,114 Volume (fF) of Cond. Space: 13,553 Air Tumover Rate (per hour): 1.1 Building toads Total Heating Required With Outside Air: 18,380 Btuh 18.380 MBH Total Sensible Gain: 4,518 Btuh 80 % Total Latent Gain: 1,112 Btuh 20 % Total Cooling Required With Outside Air: 5,630 Btuh 0.47 Tons (Based On Sensible + Latent) 0.50 Tons (Based On 75% Sensible Capacity) ~ Nofes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I i i i ~ i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\dver ridge unit B.rhv Monday, September 09, 2013,1:04 PM (Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc, Minnesota Air River Ridge Town Home Unit B Bloomington. MN 55438 Pa e 6 I System 1 Room Load Summary Htg Min Run Run Cig Clg Min AcP1 Room Area Sens Htg Duct Duct Sens Lat Cig Sys. No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM L --Zone 1--- 1 Basement 543 7,498 100 1-6 511 1,117 528 52 100 2 Main Floor 510 5,865 79 1-5 576 1,675 309 78 79 ~PPer Floor_ 510 5,017 _ 67 _ 1-5 493 1,726 275 81 67 System 1 total 1,563 18,380 246 4,518 1,112 212 246 System 1 Main Trunk Size: 7x7 in. Velocity: 723 ft./min i Loss per 100 ft.: 0.157 in.wg Cooling m Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.47 80%/20% 4,518 1,112 5,630 Recommended: 0.50 75%/25% 4,518 1,506 6,023 i Equipment Data Heating System Cooling Sys System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh i 1 i C:\Users\Chad.MNAIR\Desktop\Office Doc\SalesViver ridge unit B.rhv Monday, September 09, 2013, 1:04 PM