3176 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate
Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date CertRkate Posted
building. The certificate shall be completed by the builder and shall list information and values of components ?A g
listed in Table N1101.8.
MalingAddmss oflbe DwoMag or Dwelang lnit City WGOA
Riverview Avenue Eagan
Name of Residential Contractor MN License Number
Superior Companies of Minnesota Inc MB4551
THERMAL ENVELOPE RADON SYSTEM _
Type: Check All That Apply X Passive (No Fan )
o d
v °
Active (With fan and monometer or
other system monitoring device)
N U 9 O N
w U - Te
W PQ o U
O N N p V roe 22 U
Insulation Location > o z v a u. W
4 ~ `o m eo O -0
c ~
E° z w w t° w° Cx cG Other Please Describe Here
Below Entire Slab X
Foundation Wall 10 X Type in location: interior exterior or integral
Perimeter of Slab on Grade 10 X
Rim Joist (Foundation) 19 X Type in location: interior exterior or integral
Rim Joist (1't Floor+) 19 X Type in location: interior exterior or integral
Waft 23 X
Ceilin , flat 49 X
Ceiling, vaulted X
Bay Windows or cantilevered areas 56.5 X X
Bonus room over garage 556.5 X X
Describe other insulated areas
Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC): 0.33 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code
Fuel Type NG NG Electric Passive
Manufacturer Carrier AO Smith Carrier Powered
Interlocked with exhaust device.
Model 59TP5A040E14 GPD-40 24ACB31BA30 Describe:
Input in 40,000 Capacityin 40 Output in 1.5 Other, describe:
Rating or Size BTUS: Gallons: Tons:
Heat Loss: 22,714 Heat Gain: 9,138 Location of duct or system:
Structure's Calculated
AFUE or 96.5 SEER: 15.5
HSPF%
Calculated 9,138
Efficiency cooling load: Cfin's
" round duct OR
Mechanical Ventilation System "metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type -
source heat pump with gas back-up furnace): Not required per mech. code
Select Type X Passive
Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe:
Energy Recover Ventilator (ERV) Capacity in cfr s: Low: Hi : Location of duct or system:
Continuous exhausting fan(s) rated capacity in efins:
Location of fan(s), describe: Cfin's
E Ca acity contumous ventilation rate in efins: 44 6 " round duct OR
Total ventilation (intermittent + continuous) rate in efins: 87 " metal duct
Date: 7/1/2013 Revision Date: 7/1/2013 New Construction
Site Information
Address 1: Type A Unit Project
Address 2: ,3/ 7~ ?,iY" sCk10AVM o Lot: Block:
City: Eagan County: Subdivision:
Application Information
Business Name: Superior Mechanical MN Contractor License
Contact Person: Rob Jones
Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph:
Address 1: 1244 60th Avenue NW
City: Rochester State: MN Zip Code: 55901
House Details
Square Feet: 1363 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 3
Ventilation : Exhaust
Total Ventilation Capacity : 60 cfm:
Minimum Continuous Ventilation :60cfm.
Ventilation: Exhaust: 60 cfm.
Combustion Appliance
Water Heater. Power Vent Input BTUs: 40,000 Independently Vented
Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 40,000 Independently Vented
Other Combustion Appliances
Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No
Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No
Exhaust Equipment
Exhaust Ventilation Capacity (cfm): 60 Clothes Dryer (cfm): 135
Exhaust Fan Rating (cfm): 175
Make-Up Air
Total Make-Up Air Required (cfm): 131
Passive Make-Up, Round Rigid: 6 inches or Insulated Flex: 7 inches
Combustion Air
Round Rigid Required: 4 inches or Insulated Flex: 5 inches
r1SGG/7/I, y /G L Ri>o m SI ZG : 7 413 Y. 5 = _7Z9 FT3
Applicant Name (print): S~,P ,flR-m a, ~~vK \Las Signature /Date: ; 9- -13
Code Official (print): Signature/Date:
0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I
2009 Mechanical & Energy Code -Ventilation, Makeup, and Combustion Air Calculations
Please submit at time of application of a mechanical permit for new construction
Site address Y(74 'U i Ui U& Date
Hvac tAPt21cQ AA9165 a Mirrrl&SOrA ,~ompleted
contractor By CJD
Section A
Ventilation Quantity
(Determine quantity by using Table N1104.2 or Equation 11-1)
Square feet (Conditioned area including 2
Basement - finished or unfinished) 13 3 Total required ventilation
Number of bedrooms 3 Continuous ventilation
Section B
Ventilation Method
(Choose either balanced or exhaust only)
Ej Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy [K Exhaust only
Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm
continuous ventilation rating by more than 100%.
Low dm: High dm: Continuous fan rating in cfm (capacity must not exceed
continuous ventilation rating b more than 100%
Section C
Ventilation Fan Schedule
Description Location Continuous Total Ventilation
Q D I C' VO&V K53 P &c. W1wpm,
9P'tAU(' 9d 15 175 1
t' Section D
Controls
(Describe operation and control of the continuous ventilation
Tn1'ftsr~AL t".OfJtIfJU us Ve riL.ATlo Tr
>r V 't
Section E
Make-up air for ventilation
Passive (determined from calculations from Table 5D1.4. 1)
Powered (determined from calculations from Table 501.4.1)
Interlocked with exhaust device (determined from calculation from Table 501.4.1)
Other, describe: 4
Location of duct or system ventilation make-up air: Determined from make-up air opening table
Cfm -5 1 Size and type (round, rectangular, flex or rigid)
Section F
Make-up air for combustion
Not required per mechanical code (No atmospheric or power vented appliances)
Passive (see IFGC Appendix E, Worksheet E-1) Size and type Lis 0 DUdl
Other, describe:
Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be
submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at:
j River Ridge Town Home Unit A
HVAC Load Calculations
for
Superior Mechanical
1244 60th Ave NW
Rochester, MN 55901
i
i
i
FT
wwL is wvAc I
R.usmrm iALt
HVC: LoADs
i
Prepared By:
Monday, September 09, 2013
i
i
i
Rhvac - Residential & Ught Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit A
Bloomington MN 55438 Page 2
Project R_pott
General' Project Information _ =
Project Title: River Ridge Town Home Unit A
Project Date: Tuesday, July 02, 2013
Client Name: Superior Mechanical
Client Address: 1244 60th Ave NW
Client City: Rochester, MN 55901
Desi nData
Reference City: Minneapolis, Minnesota
Daily Temperature Range: Medium I
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
i Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
DpIy Bulb Wet Bulb Rel.Hum Dry Bulb Difference
Winter: -20 0 30 72 34
Summer: 92 73 50 72 35
Check Figures
Total Building Supply CFM: 382 CFM Per Square ft.. 0.280
Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505
Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
Brildin9"Loads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Btuh 11 %
Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent)
0.91 Tons (Based On 75% Sensible Capacity)
Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
i
I
i
I
i
I
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
hvac - Residential & Light Commercial HVAC Loads Elite sottware Development, Inc. I
Minnesota Air River Ridge Town Home Unit A
1 Bloomington. MN 55438 Page 3
Miscellaneous Report
- - = - -
System 1 Outdoor Outdoor Indoor Indoor Grains
i Input Data Dry Bulb Wet Bulbs Rel.Hum Dry Bulb Difference
j Winter: -20 0 30 72 34.40
Summer: 92 73 50 72 35.16
Duc St nizi; g llnputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data _
Winter - Summer
Infiltration: 0.430 AC/hr 0.230 AC/hr
Above Grade Volume: X 11.038 Cu.ft. X 11,038 Cu.ft.
4,746 Cu.ft./hr 2,539 Cu.ft./hr
X0.0167 x0.0167
Total Building Infiltration: 79 CFM 42 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference)
i w
i
i
i
I
I
j
I
i
i
i
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
C Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit A
Bloomington, MN 55438 _ Page 4
Load Preview Report
, Sys
Has Net Rec R.2; Sen Lat! Net Sen Hts Cls Act Duct
Scope AED Ton Ton' /Ton Area Gain: Gain, Gain Loss g g Size
CFM CFM CFMi
Building 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382
System 1 Yes 0.76 0.91 1,505 1,364 8,157 981 9,138 22,714 304 382 382 9x9
Zone1 1,364 8,157 981 9,138 22,714 304 382 382 9x9
1-Basement 104 655 206 861 5,392 72 31 31 1.4
2-Main Floor 630 3,535 399 3,934 8,797 118 166 166 2-5
3-2nd Floor 630 3,967 376 4,343 8,525 114 186 186 2-6
l
f
i
I
i
C:\Users\Chad.MNAIR\Desktop\Oifice Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc
Minnesota Air River Ridge Town Home Unit A
Bloomington MN 55438 P e 5
Total Building Summary Loads
Area Sen Lot Sen Total
Description, Quan Loss Gain Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 172.5 4,761 0 4,914 4,914
Low e, u-value 0.3, SHGC 0.33
11P: Door-Metal- Polyurethane Core 42 1,120 0 378 378
15A-10sffc-8: Wall-Basement, concrete block wall, R-10 123.5 537 0 26 26
foam board to floor, no framing, no interior finish,
filled core, 8' floor depth
R-23 wall: Wall-Frame, , R-23 insulated wall 1237.2 4,939 0 1,090 1,090
15a-1-sffc-8: Wall- 76 421 0 22 22
Under Attic w/ R-49: Roof/Ceiling-Under Attic with 630 1,159 0 693 693
Insulation on Attic Floor (also use for Knee Walls and j
Partition Ceilings), Custom, Vented Attic, Dark
Asphalt Shingles
21A-20: Floor-Basement, Concrete slab, any thickness, 2 104 258 0 0 0
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide
22D-10pm: Floor-Slab on grade, Vertical board insulation 30 947 0 0 0
covers slab edge, turns under slab and extends 4'
horizontally, any floor cover, R-10 insulation, passive,
heavy dry or light wet soil
R-56.5: Floor-Over open crawl space or garage, Custom, 486 805 0 131 131 I
R-56.5 Over Open Crawl or Garage Floor
Subtotals for structure: 14,947 0 7,254 7,254
People: 0 0 0 0
Equipment: 0 0 0
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 79, Summer CFM: 42 7,767 981 903 1,884
Ventilation: Winter CFM; 0, Summer CFM: 0 .0 _ . 0 0 . 0
Total Building Load Totals: 22,714 981 8,157 9,138
Check Figures
Total Building Supply CFM: 382 CFM Per Square ft.: 0.280
Square ft. of Room Area: 1,364 Square ft. Per Ton: 1,505
Volume (ft') of Cond. Space: 11,383 Air Turnover Rate (per hour): 2.0
Building Loads
Total Heating Required With Outside Air: 22,714 Btuh 22.714 MBH
Total Sensible Gain: 8,157 Btuh 89 %
Total Latent Gain: 981 Btuh 11 %
Total Cooling Required With Outside Air: 9,138 Btuh 0.76 Tons (Based On Sensible + Latent)
0.91 Tons (Based On 75% Sensible Capacity)
1 Notes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
r
I
r
I
i
i
I
C:\Users\Chad.MNAIR\Desktop\Offlce Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013, 11:55 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Minnesota Air River Ridge Town Home Unit A
Bloomington. MN 55438 Page 6
j System 1 Room Load Summary
Htg Min ---Run - Run _..:.Clg Min - = Aot,l
Room Area Sens Htg Duct Duct Sens Lat Clg Sys II„
No Name SF Btuh _ CFM Size - Vel Btuh Btuh CFM ; CFM
---Zone 1---
1 Basement 104 5,392 72 1-4 352 655 206 31 31
2 Main Floor 630 8,797 118 2-5 607 3,535 399 166 166
3 2nd Floor_ 630 8,525 473 3,967 _ 376 186 186
System 1 total 1,364 22,714 304 8,157 981 382 382
System 1 Main Trunk Size: 9x9 in.
Velocity: 679 ft./min
Loss per 100 ft.: 0.117 in.wg
.Cooling Sy' tem Sumarv
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btu
-h Btuh
Net Required: 0.76 89%/11% 8,157 981 9,138
Recommended: 0.91 75%/25% 8,157 2,719 10,876
Eguipment.Data -
Heating System Cooling System
Type:
Model:
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
I
i
I
I
I
l
C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit A.rhv Monday, September 09, 2013,11:55 AM