Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
3162 Riverview Ave - Energy Compliance Forms
New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Certlneate Posted building The certificate shall be completed by the builder and shall list information and values of components r listed in Table NI 101.8. MalangAddress oftheDwelling orDwelling Unit City SUPERIOR 44,, I tIZ Riverview Avenue Eagan Name of Residential Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) o y 2 Active (With fan and monometer or F r other system monitoring device) ° ° c ar a w « ~ @ !n Cj m V v a T Insulation Location a ° z U g m o u b d y O ;O O S oa Qa F ac w' w w w i~ Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location: interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19 X1 I Type in location: interior exterior or integral Rim Joist (1°t Floor+) 19 X Type in location: interior exterior or integral wait 23 X Ceiling, flat 49 X Ceiling, vaulted 11XX ay ows or cantilevered areas 56.5 X Bonus room over garage 56.5 X Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned ace Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB318A30 Describe: Input in 40,000 Capacity in 40 Output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 20,872 Heat Gain: 11 5,391 Location of duct or system: Structure's Calculated AFUE or 96.5 SEER: 15.5 HSPF% Calculated 5,391 Efficient cooling load: Cfm's " round duct OR Mechanical Ventilation System " metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code_ Select Tye X Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: Energy Recover Ventilator (ER V) Capacity in cfms: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: Cftn's Capacity continuous ventilation rate in cfms: 44 6 " round duct OR Total ventilation (intermittent + continuous) rate in cfms: 87 " metal duct Date: 6/512013 Revision Date: 6/5/2013 New Construction Site Information Address 1: Type C Unit Project 3&& .4 LDU\i i L),, AA4 Address 2: .5162 &e (-V; pU1 \q e nU a Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 993 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 35,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 45,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 171 Passive Make-Up, Round Rigid: 7 inches or Insulated Flex: 8 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches mEG3RJ,~,gL ~wo+-- 5,?..~. x,Zx$ c 57:, F73 Applicant Name (print):SmfAAok P~h3j Sc./U cl ja Signature/Date:. Code Official (print): Signature/Date: © 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site address 2 iveryibv Avbna, Date HVAC t b2 CamPANIe.S of: MtAKNcSOYA I Completed t Contractor &D 3%AeceivL IkA ANN r'4 L, B RDb Uonfb Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet (Conditioned area including (r~~ Basement - finished or unfinished) -f 3 Total required ventilation Number of bedrooms Z Continuous ventilation 33 Section B Ventilation Method Choose either balanced or exhaust only) F1 Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy ® Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating chn continuous ventilation ratio b more than 100%. Low cfm: High cfm: Continuous fan rating in dm (capacity must not exceed continuous ventilation ratio by more than 100% Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation 1PanUSvv1it, #FVb8VK83 KAOL"A Lupo l LCLT lr-Ovro_ 33 Kif Section D Controls Describe o eration and control of the continuous ventilation r CD nLA0 vesyb a 4'i Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4. 1) Powered (determined from calculations from Table 501.4.1) Interlocked with exhaust device (determined from calculation from Table 501.4.1) Other, describe: IJ A Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm 13.5 Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type 1 lZ OuLf_ Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: River Ridge Town Home Unit C HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 t will m, H-,-,,, V, A C - H VAC LoAD Prepared By: Monday, September 09, 2013 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air ) River Ridge Town Home Unit C Bloomin ton MN 5438. Pa e 2 Proiect Report General Project Information Project Title: River Ridge Town Home Unit C Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 Desi n Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor -Outdoor Indoor Indoor Grains DI~t Bulb W Bulb Rel.Hum DjyBlb- Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Figures Total Building Supply CFM: 279 CFM Per Square ft.: 0.276 Square ft. of Room Area: 1,012 Square ft. Per Ton: 1,988 Volume (ft3) of Cond. Space: 9,100 Air Turnover Rate (per hour): 1.8 'Building Loads Total Heating Required With Outside Air: 20,872 Btuh 20.872 MBH Total Sensible Gain: 4,582 Btuh 85 % Total Latent Gain: 809 Btuh 15 % Total Cooling Required With Outside Air: 5,391 Stuh 0.45 Tons (Based On Sensible + Latent) 0.51 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\Rlver Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software.Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington, MN 55438 P e 3 Miscellaneous Report System 1 Outdoor Outdoor Indoor Indoor Grains Input Data D Bulb Wet Bulb Rel.Hum D Bulb Differe ce Winter: -20 0 30 72 34.40 Summer: 92 73 50 72 35.16 Duct Sizing Inputs Main Try Runcuts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg.1100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 9.100 Cu.ft. X 9,100 Cu.ft. 3,913 Cu.ft./hr 2,093 Cu.ft./hr X 0.0167 X 0,0167 Total Building Infiltration: 65 CFM 35 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) 1 C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington, MN 5543 Paae 4 Load Preview Report i Sys; Sys; Sys: Has Net Rec ft 2 Sen tat Net* San" Duct Htg; CIg; Act: Scope AED, Ton Tone /Toni Areal Gain Gain Gain Loss Sii i CFMi.CFMi CFM - _ 1. Building 0.45 0.51 1,988 1,012 4,582 809 5,391 20,872 279 215 279 System 1 No 0.45 0.51 1,988 1,012 4,582 809 5,391 20,872 279 215 279 7x7 Zone 1 1,012 4,582 809 5,391 20,872 279 215 279 7x7 1-Laundry/foyer 116 625 140 765 3,541 47 29 47 1.4 2-Kitchen 120 652 149 801 3,725 50 31 50 1-4 3-Living 276 1,031 130 1,161 3,612 48 48 48 1-4 4-Bath 1 158 458 49 507 1,489 20 21 20 1- 5-Bed Room 1 & 2 342 1,817 341 2,158 8,505 114 85 114 1-6 I I I C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington. MN 55438 Paae 5 Total Building Summa Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain Dbl Pane Low e: Glazing-Double Pane Operable Window 68 1,877 0 1,253 1,253 Low e, u-value 0.3, SHGC 0.33 11 P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 R-23 wall: Wall-Frame, , R-23 insulated wall 1010.5 4,034 0 890 890 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 1011 1,861 0 1,112 1,112 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented "Attic, Dark Asphalt Shingles 22B-10ph: Floor-Slab on grade, Vertical board insulation 126 5,576 0 0 0 covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, passive, heavy moist soil Subtotals for structure: 14,468 0 3,633 3,633 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 Infiltration: Winter CFM: 65, Summer CFM: 35 6,404 809 746 1,555 Ventilation: Venter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 203 203 Total Building Load Totals: 20,872 809 4,582 5,391 Check Figures Total Building Supply Square ft.of Room Area: M 1,012 Square ft. Per Ton:` 10,988 I Volume (ft3) of Cond.. Space: 9,100 Air Turnover Rate (per hour): 1.8 i Building Loads Total Heating Required With Outside Air: 20,872 Btuh 20.872 MBH Total Sensible Gain: 4,582 Btuh 85 % Total Latent Gain: 809 Btuh 15 % Total Cooling Required With Outside Air: 5,391 Btuh 0.45 Tons (Based On Sensible + Latent) 0.51 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhyac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington, MN 55438 Pace 6. System I Room Load Summa Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct', Sens Lat Clg Sys a No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Laundry/foyer 116 3,541 47 1-4 543 625 140 29 47 2 Kitchen 120 3,725 50 1-4 571 652 149 31 50 3 Living 276 3,612 48 1-4 554 1,031 130 48 48 4 Bath 1 158 1,489 20 1-4 228 458 49 21 20 5 Bed Room 1 & 2 342 8,505 114 1-6 580 1,817 341 85 114 System 1. total. - 1,012 20,872..__ ._-._279._ -4,582._...._... 809. ..-..._215 279.. System 1 Main Trunk Size: 7x7 in. Velocity: 821 ft./min Loss per 100 ft.: 0.201 in.wg Coolin System Summa Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.45 85%/15% 4,582 809 5,391 Recommended: 0.51 75%/25% 4,582 1,527 6,109 ,E . ui ment Data Heating System Cooling System Type: Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM