Loading...
3164 Riverview Ave - Energy Compliance Forms New Construction Energy Code Compliance Certificate Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the Date Cerdl&ate Posted building. The certificate shall be completed by the builder and shall list infomtation and values of components listed in Table NI 101.8. Marring Address of the Dwelling or Dwelling Unit SUPERIOR City MECHANICAL 31 il Riverview Avenue Ea an ' Name of'Residemial Contractor MN License Number Superior Companies of Minnesota Inc MB4551 THERMAL ENVELOPE RADON SYSTEM Type: Check All That Apply X Passive (No Fan ) w o v 2 Active (With fan and monometer or E o other system monitoring device) o Ty o a 3 *a ~j lu ~ ~ W W v O N N O a/ w p Insulation Location a .0 z U g w v ~ y o :r g o'b 9 4 z 'w' iw w w ~ a its Other Please Describe Here Below Entire Slab X Foundation Wall 10 X Type in location. interior exterior or integral Perimeter of Slab on Grade 10 X Rim Joist (Foundation) 19. X Type in location: interior exterior or integral Rim Joist (In Floor+) 19 X Type in location: interior exterior or integral Wan 23 X Ceiling, teat 49 X Ceiling, vaulted X Bay Windows or cantilevered areas 56.5 X X Bonus room over garage 56.5 X X Describe other insulated areas Windows & Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor (excludes skylights and one door) U: 0.30 Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.33 R-value MECHANICAL SYSTEMS Make-up Air select a Type Appliances Heatin System Domestic Water Heater Cooling System X Not required per mech. code Fuel Type NG NG Electric Passive Manufacturer Carrier AO Smith Carrier Powered Interlocked with exhaust device. Model 59TP5A040E14 GPD-40 24ACB31BA30 Describe: Input in 40,000 Capacity in 40 output in 1.5 Other, describe: Rating or Size BTUS: Gallons: Tons: Heat Loss: 20,572 Heat Gain: 55,391 Location of duct or system: Structure's Calculated AFUH or 96.5 SEER: 15.5 HSPF% Calculated 5,391 Efficient cooling load: Cm's " round duct OR Mechanical Ventilation System "metal duct Describe any additional or combined beating or cooling systems if installed: (e.g. two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): Not required per mech. code Select Type X Passive Heat Recover Ventilator (HRV) Capacity in cfms: Low: High: Other, describe: Energy Recover Ventilator ERV) Capacity in &ns: Low: High: Location of duct or system: Continuous exhausting fan(s) rated capacity in cfms: Location of fan(s), describe: Cf n's Capacity continuous ventilation rate in cfins: 44 6 " round duct OR Total ventilation (intennittent + continuous) rate in cfms: 187 " metal duct Date: 6/5/2013 Revision Date: 6/5/2013 New Construction Site Information Address 1: Type C Unit Project Lh4 Address 2: ej (-V; Lvd A,V LA uR . Lot: Block: City: Eagan County: Subdivision: Application Information Business Name: Superior Mechanical MN Contractor License Contact Person: Rob Jones Office Ph: 507-289-0229 Fax: 507-281-9807 Cell Ph: Address 1: 1244 60th Avenue NW City: Rochester State: MN Zip Code: 55901 House Details Square Feet: 993 sq. ft. Avg. Ceiling Ht: 8 ft. Number of Bedrooms: 2 Ventilation : Exhaust Total Ventilation Capacity : 45 cfm. Minimum Continuous Ventilation :45cfm. Ventilation: Exhaust: 45 cfm. Combustion Appliance Water Heater: Power Vent Input BTUs: 35,000 Independently Vented Furnace/Boiler: Direct Vent/Sealed Combustion Input BTUs: 45,000 Independently Vented Other Combustion Appliances Gas Fired Direct Vent Fireplace(s): No Gas Fired Power Vent Fireplace(s): No Gas Fired Natural Draft Fireplace(s): No Solid Fuel Appliance(s): No Exhaust Equipment Exhaust Ventilation Capacity (cfm): 45 Clothes Dryer (cfm): 135 Exhaust Fan Rating (cfm): 175 Make-Up Air Total Make-Up Air Required (cfm): 171 Passive Make-Up, Round Rigid: 7 inches or Insulated Flex: 8 inches Combustion Air Round Rigid Required: 4 inches or Insulated Flex: 5 inches M EG4R..31 &}a.- 512.4 (o 1ZY-Qj = 574. F73 Applicant Name (print):S~Q I'~Lhl rans~~ b Jxoa Signature/Date: -d Code Official (print): Signature/Date: 0 2004 CenterPoint Energy Minnegasco. 2004 Mechanical Code Guidelines. Page I 2009 Mechanical & Energy Code - Ventilation, Makeup, and Combustion Air Calculations Please submit at time of application of a mechanical permit for new construction Site atldress P iv erUi bt, Aij UPS Date HVAC 1APOb(Z CDmPAt41e_6 oC MrAjUg_cpYa I Completed '~_t Contractor dida JueceioL M6ir{ANIt1.t L_ "It B Kbk tJDnb5 Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11.1) Square feet (Conditioned area including asement -finished or unfinished) "1 "tnJtl Total required ventilation [umab,, of bedrooms 2 Continuous ventilation 33 Section B Ventilation Method Choose either balanced or exhaust only) Ej Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy N Exhaust only Recovery Ventilator) - cfm of unit in low must not exceed Continuous fan rating cfm continuous ventilation ratio by more than 100%. Low cfm: I I High cfm: Continuous fan rating in cfm (capacity must not exceed continuous ventilation ratio b more than 100% Section C Ventilation Fan Schedule Description Location Continuous Total Ventilation 9ana5otnit, VEV08VKS3 MCL;A Leje .6OL441oDro, 33 ?1_0 i if Section D Controls Describe operation and control of the continuous ventilation inli tIVA 4bir MDZLMU&k n r CDt it I n tao LLn J 4'1Wr*T761 1 Section E Make-up air for ventilation Passive (determined from calculations from Table 501.4.1) F_ I Powered (determined from calculations from Table 501.4. 1) interlocked with exhaust device (determined from calculation from Table 501A, I) Other, describe: A Location of duct or system ventilation make-up air. Determined from make-up air opening table Ic"m 1,35 Size and type (round, rectangular, flex or rigid) Section F Make-up air for combustion Not required per mechanical code (No atmospheric or power vented appliances) Passive (see IFGC Appendix E, Worksheet E-1) Size and type Lo- Other, describe: Notes: Instructions and example forms are available at the Building Safety website and at the Building Safety office. This form must be submitted at the time of application of a mechanical permit for new construction. Additional forms maybe downloaded and printed at: i i i River Ridge Town Home Unit C HVAC Load Calculations for Superior Mechanical 1244 60th Ave NW Rochester, MN 55901 , I s=m»*nAL KF-IVACHVAC L4 i i j I Prepared By: Monday, September 09, 2013 i Rhvac - Residential & Light Commercial, HVAC Loads Elite Software Development, inc. Minnesota Air River Ridge Town Home Unit C1 ~ Bloomington MN 55438 Paae 2 - ~ r Pro'ect e port i :General Project Informafiori Project Title: River Ridge Town Home Unit C Project Date: Tuesday, July 02, 2013 Client Name: Superior Mechanical Client Address: 1244 60th Ave NW Client City: Rochester, MN 55901 - DesiQri Data Reference City: Minneapolis, Minnesota Daily Temperature Range: Medium Latitude: 44 Degrees i Elevation: 834 ft. Altitude Factor: 0.970 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Drv Bulb Difference Winter: -20 0 30 72 34 Summer: 92 73 50 72 35 Check Figures Total Building Supply CFM: 279 CFM Per Square ft.: 0.276 Square ft. of Room Area: 1,012 Square ft. Per Ton: 1,988 Volume (ft3) of Cond. Space: 9,100 Air Turnover Rate (per hour): 1.8 .Buildin4 Loads _ Total Heating Required With Outside Air: 20,872 Btuh 20.872 MBH Total Sensible Gain: 4,582 Btuh 85 % Total Latent Gain: 809 Btuh 15 % Total Cooling Required With Outside Air: 5,391 Btuh 0.45 Tons (Based On Sensible + Latent) 0.51 Tons (Based On 75% Sensible Capacity) i ' Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. i i i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc Minnesota Air River Ridge Town Home Unit C Bloomin ton MN 55438 Pace 3 I Miscellaneous Report _ J I 1 Outdoor Outdoor Indoor Indoor Grains [System input Data Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference j Winter: -20 0 30 72 34.40 j Summer: 92 73 50 72 35.16 `Dpct Sizind inputs ` Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration: 0.430 AC/hr 0.230 AC/hr Above Grade Volume: X 9.100 Cu.ft. X 9.100 Cu.ft. 3,913 Cu.ft./hr 2,093 Cu.ft./hr X 0.0167 X 0,0167 Total Building infiltration: 65 CFM 35 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 21.35 = (1.10 X 0.970 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 23.19 = (0.68 X 0.970 X 35.16 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 98.19 = (1.10 X 0.970 X 92.00 Winter Temp. Difference) i I i C:\Users\Chad.MNAiR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM Rhvac - Residential Light Commercial HVAC Loads Elite Software Development, Inc. l Minnesota Air River Ridge Town Home Unit C Bloomington. MN. 55438 Page 4 I Load Preview Report Has Net Rec; ft.2 Sen Laf Net Sen' Sys; Sys Sys' Duct Scope AED Ton Ton; Ron Area, Gain Gain, Gain' Loss Htgj Cigi Act Siz CFM CFM CFMi Building 0.45 0.51 1,988 1,012 4,582 809 5,391 20,872 279 215 279 j 1 System 1 No 0.45 0.51 1,988 1,012 4,582 809 5,391 20,872 279 215 279 7x7 Zone 1 1,012 4,582 809 5,391 20,872 279 215 279 7x7 1-Laundry/foyer 116 625 140 765 3,541 47 29 47 1-4 2-Kitchen 120 652 149 801 3,725 50 31 50 1-4 3-Living 276 1,031 130 1,161 3,612 48 48 48 1-4 4-Bath 1 158 458 49 507 1,489 20 21 20 1-4 5-Bed Room 1 & 2 342 1,817 341 2,158 8,505 114 85 114 1-6 f I I i i I i i I I r I C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM R ids t al &sight Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington, Page 5 Total Buildin _Summerry Loads Component Decr tion-,___--- QuArea Sen an Loss Gain - Gain Gain ; Dbi Pane Love e: Glazing-Double Pane Operable Window 68 1.877 0 1,253 1,253 Love e, u-value 0;3, SHGC 0.33 11P: Door-Metal - Polyurethane Core 42 1,120 0 378 378 R-23 wall: Wall-Frame, , R-23 insulated wall 1010.5 4,034 0 890 890 Under Attic w/ R-49: Roof/Ceiling-Under Attic with 1011 1,861 0 1,112 1,112 Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, Vented Attic, Dark I Asphalt Shingles 22B-10ph: Floor-Slab on grade, Vertical board insulation 126 5,576 0 0 0 covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, _ passive, heavy moist soil Subtotals for structure: 14,468 0 3,633 3,633 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 Ductwork: 0 0 0 0 ( Infiltration: Winter CFM: 65, Summer CFM: 35 6,404 809 746 1,555 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion 0 203 203. Total Building Load Totals: 20,872 809 4,582 5,391 Cheek Figures Total Building Suppiy CFivl: 279 CFM Per Square ft.: 0.276 Square ft. of Room Area; 1,012 Square ft. Per Ton: 1,985 Volume (ft') of Cond. Space: 9,100 Air Turnover Rate (per hour): 1.8 Building Loads Total Heating Required With Outside Air: 20,872 Btun 20.872 MBH Total Sensible Gain: 4,582 Stun 85 % Total Latent Gain: 809 Btuh 15 Total Cooling Required With {Outside Air: 5:391 Btuh 0.45 Tons (Based On Sensible + Latent) 0.51 Tons (Based On 75% Sensible Capacity) Note: Calculations are based on 8th edition ofACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. E i i t 3 C:AUsers\Chad.MNAIR\Desktop\Ofifice Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:066 IPM Rhvac -Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Minnesota Air River Ridge Town Home Unit C Bloomington. MN 55438 Page 6 . Sy 1 Room Load Summary Htg Min Run Run Clg Cig Min Act Room Area Sens Htg Duct Duct Sens Lat Ctg Sys No Name SF Btuh CFM Size _ _Vel Btuh Btuh CFM _CF.M --Zone 1--- 1 Laundry/foyer 116 3,541 47 1-4 543 625 140 29 47 2 Kitchen 120 3,725 50 1-4 571 652 149 31 50 E 3 Living 276 3,612 48 1-4 554 1,031 130 48 48 4 Bath 1 158 1,489 20 1-4 228 458 49 21 20 _ 5 Bed Room 1 & 2 342 81505 114 ,..1-6580______ 1.817 34185114 System 1 total_ _ 1,012 20,872 279 _ 4,582 809 216 279 i System 1 Main Trunk Size: 7x7 in. Velocity: 821 ft./min j Loss per 100 ft.: 0.201 in.wg Cootin S -stem Summary i Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.45 85%/15% 4,582 809 5,391 4,582 1,527 6,109 ' Eeui ment Data 0.51 75%/25% Heating System Cooling System Type: Model Brand: Efficiency: Sound: Capacity: Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh i i i I I I i C:\Users\Chad.MNAIR\Desktop\Office Doc\Sales\River Ridge Unit C.rhv Monday, September 09, 2013, 1:06 PM