4232 Blackhawk Rd - Concrete Mix DesignsTransmittal DATE:March 18, 2014 TO:Harriss ArchitectsFROM:Stonebridge Construction 515 Washington Ave. N 15734 Foliage Avenue Suite 200C Apple Valley, MN 55124 Minneapolis, MN 55401 Attn:George JohnsonProject:Eagan Pointe Senior Living Project #:1220 RE:Submittals The following submittals are attached for your review. Submittal # Description Submitting Company Date SubmittedDate Due Date Returned 002 Concrete Mix DesignsKiffmeyer 03/21/14 03/26/14 Comments I put a rush on these. Let me know if that is a problem. Thanks If you have any questions please contact me. Matthew Currie Project Manager Stonebridge Construction, Inc. 952.431.5700 mcurrie@stonebridgecommunities.com Dispatch (952) 997-9100 Sales (952) 997-9143 Project: Location: Date:March 18, 2014 Contractor:Sales Reps:Jeff Hartwig Attention: Quality Control:Josh Edwards, P.E. Peter Fischer MIX DESIGNATIONMIX #1 1 - 2 - 5 - 3 - 4 - (1) (2) (3) (4) (5) A. B. C. D. All aggregate weights are saturated surface dry (SSD) Batch water and fine aggregate content to be adjusted for aggregate absorption and moisture content to maintain specified yield Air entraining agent dosage to be adjusted for field and batching conditions to maintain the specified air content if air entraining is used Plasticizer dosage to be adjusted for field and batching conditions to maintain the desired slump ASTM: C150 Type I/II ASTM: C 618 Class C ASTM: C 33 ASTM: C 33 ASTM: C 494, TYPE A, B, D NOTES: SLUMP 4-5 INCH AIR CONTENT (CALCULATED)2.00% BATCH MATERIALS: COARSE AGGREGATE (3/4" - #4)1800 WATER - LBS.255 WATER CEMENT RATIO0.58 FLYASH - LBS.100 WATER REDUCER - OZ.13 FINE AGGREGATE - LBS.1557 AIR CONTENT DESIGN MIX CEMENT - LBS.340 PLACEMENT LOCATIONFOOTINGS COARSE AGGREGATE SIZE (MAX)3/4" - #4 SLUMP 4-5 INCH 3000 PSI AT 28 DAYS COMPRESSIVE STRENGTH - 28 DAYS3000 PSI KIFFMEYER INC. Paul Ackerman CONCRETE MIX DESIGN AVR, Inc. 14698 Galaxie Avenue Apple Valley, MN 55124 EAGAN POINT Eagan, Minnesota 39 Dispatch (952) 997-9100 Sales (952) 997-9143 Project: Location: Date:March 18, 2014 Contractor:Sales Reps:Jeff Hartwig Attention: Quality Control:Josh Edwards, P.E. Peter Fischer MIX DESIGNATIONMIX #2 1 - 2 - 5 - 3 - 4 - (1) (2) (3) (4) (5) A. B. C. D. All aggregate weights are saturated surface dry (SSD) Batch water and fine aggregate content to be adjusted for aggregate absorption and moisture content to maintain specified yield Air entraining agent dosage to be adjusted for field and batching conditions to maintain the specified air content if air entraining is used Plasticizer dosage to be adjusted for field and batching conditions to maintain the desired slump ASTM: C150 Type I/II ASTM: C 618 Class C ASTM: C 33 ASTM: C 33 ASTM: C 494, TYPE A, F NOTES: SLUMP 5-7 INCH AIR CONTENT (CALCULATED)2.50% BATCH MATERIALS: COARSE AGGREGATE (3/4" - #4)1770 WATER - LBS.282 WATER CEMENT RATIO0.50 FLYASH - LBS.0 MID-RANGE WATER REDUCER - OZ.23 FINE AGGREGATE - LBS.1430 AIR CONTENT DESIGN MIX CEMENT - LBS.564 PLACEMENT LOCATIONINTERIOR SLAB ON GRADE COARSE AGGREGATE SIZE (MAX)3/4" - #4 SLUMP 5-7 INCH 4000 PSI AT 28 DAYS COMPRESSIVE STRENGTH - 28 DAYS4000 PSI KIFFMEYER INC. Paul Ackerman CONCRETE MIX DESIGN AVR, Inc. 14698 Galaxie Avenue Apple Valley, MN 55124 EAGAN POINT Eagan, Minnesota 843 Dispatch (952) 997-9100 Sales (952) 997-9143 Project: Location: Date:March 18, 2014 Contractor:Sales Reps:Jeff Hartwig Attention: Quality Control:Josh Edwards, P.E. Peter Fischer MIX DESIGNATIONMIX #3 1 - 2 - 5 - 6 - 3 - 4 - (1) (2) (3) (4) (5) (6) A. B. C. D. CONCRETE MIX DESIGN EAGAN POINT Eagan, Minnesota KIFFMEYER INC. AVR, Inc. 14698 Galaxie Avenue Apple Valley, MN 55124 Paul Ackerman 4000 PSI AT 28 DAYS COMPRESSIVE STRENGTH - 28 DAYS4000 PSI PLACEMENT LOCATIONEXTERIOR COARSE AGGREGATE SIZE (MAX)3/4" - #4 SLUMP 4-5 INCH AIR CONTENT6.5% ± 1.5% DESIGN MIX CEMENT - LBS.564 FLYASH - LBS.0 MID-RANGE WATER REDUCER - OZ.23 AIR ENTRAINMENT - OZ.6 FINE AGGREGATE - LBS.1376 COARSE AGGREGATE (3/4" - #4)1731 WATER - LBS.254 WATER CEMENT RATIO0.45 SLUMP 4-5 INCH AIR CONTENT (CALCULATED)6.50% BATCH MATERIALS: ASTM: C150 Type I/II ASTM: C 618 Class C Batch water and fine aggregate content to be adjusted for aggregate absorption and moisture content to maintain specified yield Air entraining agent dosage to be adjusted for field and batching conditions to maintain the specified air content if air entraining is used. Plasticizer dosage to be adjusted for field and batching conditions to maintain the desired slump ASTM: C 33 ASTM: C 33 ASTM: C 494, TYPE A & F ASTM: C 260 NOTES: All aggregate weights are saturated surface dry (SSD) 842 Dispatch (952) 997-9100 Sales (952) 997-9143 Project: Location: Date:March 18, 2014 Contractor:Sales Reps:Jeff Hartwig Attention: Quality Control:Josh Edwards, P.E. Peter Fischer MIX DESIGNATIONMIX #4 1 - 2 - 5 - 6 - 3 - 4 - (1) (2) (3) (4) (5) (6) A. B. C. D. CONCRETE MIX DESIGN EAGAN POINT Eagan, Minnesota KIFFMEYER INC. AVR, Inc. 14698 Galaxie Avenue Apple Valley, MN 55124 Paul Ackerman 3000 PSI AT 28 DAYS COMPRESSIVE STRENGTH - 28 DAYS3000 PSI PLACEMENT LOCATIONCOREFILL COARSE AGGREGATE SIZE (MAX)3/8" - #8 SLUMP 6-8 INCH AIR CONTENT DESIGN MIX CEMENT - LBS.410 FLYASH - LBS.100 WATER REDUCER - OZ.20 AIR ENTRAINMENT - OZ.0 FINE AGGREGATE - LBS.1400 COARSE AGGREGATE (3/8" - #8)1800 WATER - LBS.285 WATER CEMENT RATIO0.56 SLUMP 6-8 INCH AIR CONTENT (CALCULATED)2.00% BATCH MATERIALS: ASTM: C150 Type I/II ASTM: C 618 Class C Batch water and fine aggregate content to be adjusted for aggregate absorption and moisture content to maintain specified yield Air entraining agent dosage to be adjusted for field and batching conditions to maintain the specified air content if air entraining is used. Plasticizer dosage to be adjusted for field and batching conditions to maintain the desired slump ASTM: C 33 ASTM: C 33 ASTM: C 494, TYPE A, B, D ASTM: C 260 NOTES: All aggregate weights are saturated surface dry (SSD) 59