Loading...
3905 Eagan Outlets Pkwy Unit 200 - Nike - Air Balance Test Report17135 W. 10 Mile Road   380 Northwest Highway               8401 73rd Ave North          Suite 112             Suite 210        Suite Eā€8     Southfield, MI  48075    Des Plaines, IL  60016           Minneapolis, MN  55428    Phone (248) 559ā€5864    Phone (847)759ā€1800             Phone (763) 533ā€8882                   NIKE GLOBAL        EAGAN, MINNESOTA    AIR TESTING & BALANCING REPORTS    ITB PROJECT #: MN2697              JOB NAME:NIKE GLOBAL LOCATION:EAGAN, MINNESOTA I.T.B. PROJECT #:MN2697 DATE:8/14 THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. ICB/NEBB FIRM:INTERNATIONAL TEST & BALANCE INC. CERTIFIED BY:RICK YZERMANS DATE:8/4/2014 THE HYDRONIC DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. ICB/NEBB FIRM :INTERNATIONAL TEST & BALANCE INC. CERTIFIED BY: DATE: SUBMITTED & CERTIFIED BY: INTERNATIONAL TEST & BALANCE, INC. NEBB CERTIFIED: RICK YZERMANS SIGNATURE: DATE:8/4/14 CERTIFICATION EXPIRATION DATE: CERTIFICATION INTERNATIONAL TEST & BALANCE, INC. 8401 73rd Avenue, N., Suite E-8 Minneapolis, MN 55428 Voice (763) 533-8882 Fax (763) 533-8933 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-01 AREA: ROOF Tested By: Richard Yzermans Unit Data Unit Manufacturer CARRIER Unit Model Number A04D2M6A2B4D0 Type DRAW THRU Unit Serial Number 1614C75175 Blade Type FC Filter Data 2-16X25X2 Test Data Design System Total CFM 4000 CFM Actual System Total CFM 3609 CFM Design Return Air CFM 3200 CFM Actual Return Air CFM 2753 CFM Design Outdoor Air CFM 800 CFM Actual Outdoor Air CFM 846 CFM Design Outlet Total CFM 4000 CFM Actual Outlet Total CFM 3609 CFM Actual T.F.S.P.2.59 in. wc Design T.F.S.P.1.1 in. wc Actual Fan RPM 891 RPM Design Motor RPM 1755 RPM Actual Motor RPM 1749 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 474/475/476 VOLTS Design Amperage 4.6 AMPS Actual Amperage 3.9/4.0/4.1 AMPS Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 37 % R.A. Damper Position 63 % S.P. Set Point CONSTANT Motor Data Motor Manufacturer MARATHON Frame Size 56 Service Factor 1.15 Horsepower 1.5 Sheave Data Motor Sheave VP30 Motor Sheave PD 2.3 in. Motor Sheave OD 2.9 in. Motor Bore Size 1/2 in. Fan Sheave AFD44 Fan Sheave PD 3.8 in. Fan Sheave OD 3.9 in. Fan Bore Size 5/8 in. Shaft Centers 14 1/2 in. Belt Quantity 1 Belt Number AX38 Motor Adj (Plus)2 in. Motor Adj (Minus)2 in. Test Pressures Suction SP -2.16 in. wc Discharge SP 0.43 in. wc 1-Aug-14 O/A TRAVERSE=34X20=4.7 X 180 FPM=846 CFM @37% OF DAMPER RTU-01 Richard Yzermans 1-Aug-14 S/A TRAVERSE=34X20=4.7 X 768 FPM=3609 CFM OUTLETS SET TO TRAVERSING TOTAL RTU-01 Richard Yzermans * Notes International Test & Balance, Inc. Page 1 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-02 AREA: ROOF Tested By: Richard Yzermans Unit Data Unit Manufacturer CARRIER Unit Model Number A06D2M6A2B4D0 Type DRAW THRU Unit Serial Number 1614C75351 Blade Type FC Filter Data 4-16X16X2 Test Data Design System Total CFM 5000 CFM Actual System Total CFM 5294 CFM Design Return Air CFM 4320 CFM Actual Return Air CFM 4583 CFM Design Outdoor Air CFM 680 CFM Actual Outdoor Air CFM 711 CFM Design Outlet Total CFM 5000 CFM Actual Outlet Total CFM 5294 CFM Actual T.F.S.P..98 in. wc Design T.F.S.P.1.1 in. wc Actual Fan RPM 685 RPM Design Motor RPM 1755 RPM Actual Motor RPM 1769 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 475/471/477 VOLTS Design Amperage 4.6 AMPS Actual Amperage 2.2/2.2/2.4 AMPS Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 10 % R.A. Damper Position 90 % S.P. Set Point CONSTANT Motor Data Motor Manufacturer MARATHON Frame Size 60 Service Factor 1.15 PF .7 EFF .8 Sheave Data Motor Sheave VP40 Motor Sheave PD 3.3 in. Motor Sheave OD 3.9 in. Motor Bore Size 5/8 in. Fan Sheave AFD44 Fan Sheave PD 3.9 in. Fan Sheave OD 3.9 in. Fan Bore Size 5/8 in. Shaft Centers 14 1/4 in. Belt Quantity 1 Belt Number AX38 Motor Adj (Plus)3 in. Motor Adj (Minus)1 in. Test Pressures Suction SP -.93 in. wc Discharge SP 0.05 in. wc 1-Aug-14 O/A TRAVERSE=62 X 24=10.3 X 69 FPM=711 CFM @10% OF DAMPER RTU-02 Richard Yzermans 1-Aug-14 S/A TRAVERSE=62 X 24=10.3 X 514 FPM=5294 CFM OUTLETS SET TO TRAVERSING TOTAL RTU-02 Richard Yzermans * Notes International Test & Balance, Inc. Page 2 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-03 AREA: ROOF Tested By: Richard Yzermans Unit Data Unit Manufacturer CARRIER Unit Model Number E11D2M6A2B4K0 Type DRAW THRU Unit Serial Number 1314P83113 Blade Type FC Filter Data 4-20X20X2 Test Data Design System Total CFM 5000 CFM Actual System Total CFM 5026 CFM Design Return Air CFM 4320 CFM Actual Return Air CFM 4356 CFM Design Outdoor Air CFM 680 CFM Actual Outdoor Air CFM 670 CFM Design Outlet Total CFM 5000 CFM Actual Outlet Total CFM 5026 CFM Actual T.F.S.P.1.10 in. wc Design T.F.S.P.1.1 in. wc Actual Fan RPM 743 RPM Design Motor RPM 1755 RPM Actual Motor RPM 1763 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 470/478/474 VOLTS Design Amperage 4.6 AMPS Actual Amperage 2.6/2.5/2.9 AMPS Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 10 % R.A. Damper Position 90 % S.P. Set Point CONSTANT Motor Data Motor Manufacturer MARATHON Frame Size 60 Service Factor 1.15 PF .7 EFF .8 Sheave Data Motor Sheave 1 VL 40 Motor Sheave PD 3 in. Motor Sheave OD 3.9 in. Motor Bore Size 7/8 in. Fan Sheave AFD74 Fan Sheave PD 6.8 in. Fan Sheave OD 6.9 in. Fan Bore Size 1 in. Shaft Centers 17 in. Belt Quantity 1 Belt Number AX49 Motor Adj (Plus)4 in. Test Pressures Suction SP -.89 in. wc Discharge SP 0.21 in. wc 1-Aug-14 O/A TRAVERSE=62 X24=10.3 X 65 FPM=670 CFM @10% OF DAMPER RTU-03 Richard Yzermans 1-Aug-14 S/A TRAVERSE=62 X 24=10.3 X 488 FPM=5026 CFM OUTLETS SET TO TRAVERSING TOTAL RTU-03 Richard Yzermans * Notes International Test & Balance, Inc. Page 3 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-04 AREA: ROOF Tested By: Richard Yzermans Unit Data Unit Manufacturer CARRIER Unit Model Number E17D2M6A2B4G0 Type DRAW THRU Unit Serial Number 1614P24858 Blade Type FC Filter Data 6-20X25X2 Test Data Design System Total CFM 1800 CFM Actual System Total CFM 1874 CFM Design Return Air CFM 1245 CFM Actual Return Air CFM 1299 CFM Design Outdoor Air CFM 555 CFM Actual Outdoor Air CFM 575 CFM Design Outlet Total CFM 1800 CFM Actual Outlet Total CFM 1874 CFM Actual T.F.S.P.2.43 in. wc Design T.F.S.P.2.2 in. wc Actual Fan RPM 888 RPM Design Motor RPM 1755 RPM Actual Motor RPM 1749 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 472/474/477 VOLTS Design Amperage 2.9 AMPS Actual Amperage 2.9/3.0/2.9 AMPS Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 25 % R.A. Damper Position 75 % S.P. Set Point CONSTANT Motor Data Motor Manufacturer MARTHON Frame Size 48 Service Factor 1.15 PF .7 EFF .8 Sheave Data Motor Sheave 1 VL 40 Motor Sheave PD 3.7 in. Motor Sheave OD 3.9 in. Motor Bore Size 7/8 in. Fan Sheave AFD 49 Fan Sheave PD 4.4 in. Fan Sheave OD 4.6 in. Fan Bore Size 1 in. Shaft Centers 15 in. Belt Quantity 1 Belt Number A-46 Motor Adj (Plus)3 in. Motor Adj (Minus)1 in. Test Pressures Suction SP -1.41 in. wc Discharge SP 1.02 in. wc 1-Aug-14 O/A TRAVERSE=28X14=2.7 X 213 FPM=575 CFM @25% OF DAMPER RTU-04 Richard Yzermans 1-Aug-14 S/A TRAVERSE=28X14=2.7 X 694 FPM=1874 CFM OUTLETS SET TO TRAVERSING TOTAL RTU-04 Richard Yzermans * Notes International Test & Balance, Inc. Page 4 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-05 AREA: ROOF Tested By: Richard Yzermans Unit Data Unit Manufacturer CARRIER Unit Model Number E17D2M6A2B4G0 Type DRAW THRU Unit Serial Number 1614P24859 Blade Type FC Filter Data 6-20X25X2 Test Data Design System Total CFM 1200 CFM Actual System Total CFM 1220 CFM Design Return Air CFM 1070 CFM Actual Return Air CFM 1077 CFM Design Outdoor Air CFM 130 CFM Actual Outdoor Air CFM 143 CFM Design Outlet Total CFM 1200 CFM Actual Outlet Total CFM 1220 CFM Actual T.F.S.P.1.02 in. wc Design T.F.S.P.1.1 in. wc Actual Fan RPM 900 RPM Design Motor RPM 1755 RPM Actual Motor RPM 1748 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 472/473/474 VOLTS Design Amperage 2.9 AMPS Actual Amperage 2.3/2.4/2.5 AMPS Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 5 % R.A. Damper Position 95 % S.P. Set Point CONSTANT Motor Data Motor Manufacturer MARATHON Frame Size 60 Service Factor 1.15 Sheave Data Motor Sheave 1 VL 40 Motor Sheave PD 3.5 in. Motor Sheave OD 3.9 in. Motor Bore Size 7/8 in. Fan Sheave BK100 Fan Sheave PD 4.5 in. Fan Sheave OD 4.9 in. Fan Bore Size 1 in. Shaft Centers 11 1/2 in. Belt Quantity 1 Belt Number BX44 Motor Adj (Minus)4 in. Test Pressures Suction SP -.51 in. wc Discharge SP 0.51 in. wc RTU-05 Supply Outlet Summary AK Factor % Final Diff. Final Airflow Prelim Airflow Design Airflow InstrumentSize Outlet Type Area ServedSystem / Unit EMPLOYEE LOUNGESAD8Outlet-01 1.0017097HOOD175250 EMPLOYEE LOUNGESAD8Outlet-02 1.0017097HOOD175225 ASM OFFICE SAD8Outlet-03 1.00200100HOOD200220 AV RM SAD8Outlet-04 1.00220126HOOD175160 OFFICE SAD6Outlet-05 1.009090HOOD10090 HC OFFICE SAD6Outlet-06 1.00125100HOOD125140 HALLWAY SAD8Outlet-07 1.0014597HOOD150175 BATHROOM SAD6Outlet-08 1.0050100HOOD5060 BATHROOM SAD6Outlet-09 1.0050100HOOD5060 ----- 1,200 1,380 1,220Totals : 102 % International Test & Balance, Inc. Page 5 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Roof Top Unit PROJECT #: MN2697 Test Date: August 01, 2014 SYSTEM/UNIT: RTU-05 (Cont.) AREA: ROOF Tested By: Richard Yzermans 1-Aug-14 O/A TRAVERSE=28X14=2.7 X 53 FPM=143 CFM @5% OF DAMPER RTU-05 Richard Yzermans 1-Aug-14 Deficiency 0001 : UNACCESSABLE DAMPER. CAN NOT REACH DAMPER TO LOWER CFM. RTU-05 / Outlet-04 Richard Yzermans * Notes International Test & Balance, Inc. Page 6 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Fan Unit PROJECT #: MN2697 Test Date: August 04, 2014 SYSTEM/UNIT: EF-01 AREA: ROOF Tested By: Richard Yzermans Unit Data Fan Manufacturer GREENHECK Fan Model Number G-080-D-X Fan Serial Number 13700262 Starter Data Starter Manufacturer DIRECT DRIVE Starter Model No.DIRECT DRIVE Starter Size DIRECT DRIVE Rated Amps DIRECT DRIVE Amps Required Amps DIRECT DRIVE Amps Test Data Design Airflow 250 CFM Actual Airflow 205 CFM Design RPM 1550 RPM Actual RPM 1350 RPM Motor Volts T1-T2 119 Volts Motor Volts T2-T3 119 Volts Motor Volts T1-T3 119 Volts Motor Amps T1 0.80 Amps Motor Amps T2 0.80 Amps Motor Amps T3 0.80 Amps Suction SP DIRECT DRIVE in. wc Discharge SP DIRECT DRIVE in. wc Motor Data Rated Airflow Capacity 250 CFM Motor Manufacturer MCMILLAN Motor Frame FRAC Motor HP 1/20 HP Motor RPM 1550 RPM Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.20 Amps Motor Service Factor TP Brake Horse Power 0.03 BHP Corrected FL Amps 1.16 Amps Nominal Efficiency 0.80 % Power Factor 0.70 Sheave Data Motor Sheave MFG DIRECT DRIVE Motor Sheave Model DIRECT DRIVE Motor Sheave Diam.OD DIRECT DRIVE Motor Sheave Bore DIRECT DRIVE Fan Sheave MFG DIRECT DRIVE Fan Sheave Model DIRECT DRIVE Fan Sheave Diam. OD DIRECT DRIVE Fan Sheave Diam. PD DIRECT DRIVE Fan Sheave Bore DIRECT DRIVE Number of Belts DIRECT DRIVE Belt Size DIRECT DRIVE Sheave Center Line DIRECT DRIVE EF-01 Exhaust Inlet Summary % Final Diff. InstrumentActual Velocit Final Airflow Prelim Airflow Design Airflow Size Inlet Type Area ServedSystem / Unit BATHROOM EAG6Inlet-01 100HOOD100100100 BATHROOM EAG6Inlet-02 60HOOD1006060 JANITOR CLOSETEAG6Inlet-03 90225RVA504545 ----- 250 205 205Totals : 82 % 1-Aug-14 Deficiency 0002 : EX-FAN WIRED TO MEDIUM. DOING 205/250 CFM. .8 AMPS OUT OF 1.2 DESIGN EF-01 Richard Yzermans* Notes International Test & Balance, Inc. Page 7 of 8 PROJECT: NIKE GLOBAL LOCATION: EAGAN, MN DATE: 8/4/2014 CONTACT: Richard Yzermans Fan Unit PROJECT #: MN2697 Test Date: August 04, 2014 SYSTEM/UNIT: EF-02 AREA: ROOF Tested By: Richard Yzermans Unit Data Fan Manufacturer GREENHECK Starter Data Starter Manufacturer DIRECT DRIVE Starter Model No.DIRECT DRIVE Starter Size DIRECT DRIVE Rated Amps DIRECT DRIVE Amps Required Amps DIRECT DRIVE Amps Test Data Design Airflow 250 CFM Actual Airflow 260 CFM Design RPM DIRECT DRIVE RPM Actual RPM DIRECT DRIVE RPM Motor Volts T1-T2 119 Volts Motor Volts T2-T3 119 Volts Motor Volts T1-T3 119 Volts Motor Amps T1 1.10 Amps Motor Amps T2 1.10 Amps Motor Amps T3 1.10 Amps Suction SP DIRECT DRIVE in. wc Discharge SP DIRECT DRIVE in. wc Motor Data Rated Airflow Capacity 250 CFM Motor Manufacturer FASCO Motor Frame FRAC Motor RPM 950 RPM Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.30 Amps Motor Service Factor TP Corrected FL Amps 1.26 Amps Nominal Efficiency 0.80 % Power Factor 0.70 Sheave Data Motor Sheave MFG DIRECT DRIVE Motor Sheave Model DIRECT DRIVE Motor Sheave Diam.OD DIRECT DRIVE Motor Sheave Bore DIRECT DRIVE Fan Sheave MFG DIRECT DRIVE Fan Sheave Model DIRECT DRIVE Fan Sheave Diam. OD DIRECT DRIVE Fan Sheave Diam. PD DIRECT DRIVE Fan Sheave Bore DIRECT DRIVE Number of Belts DIRECT DRIVE Belt Size DIRECT DRIVE Sheave Center Line DIRECT DRIVE * Notes International Test & Balance, Inc. Page 8 of 8