Loading...
3925 Eagan Outlets Pkwy Ste 940 - Samsonite - Testing & Balancing Report 375 230th Ave, Somerset WI 54025 - Phone: (612) 834-0311 Fax: (414) 377-3349 www.Premierbalancing.com 'rl~$~r~a, gpdu;na¢ .v+o ~e. ~HCinG euuC~t} trs oaoreasroHni ; Ho3t~" Testing, Adjusting & Balancing Report TABB TECHNICIAN Technician: Tony Kompelien Cell Phone: 612-419-1425 Email Address: tony@premierbalancing.com PROJECT Sampsonite Paragon Outlets Twin Cities Suite 940 CLIENT Allan Mechanical Contractors 7875 Fuller Road Eden Prairie, MN 55344 ENGINEER Larson Binkley 310 W 20th St. Suite 200 Kansas City, MO 64108 Report Date August 1, 2014 TABB CERTIFICATION TABB certification of a Supervisor is TABB's statement that the Supervisor is able to supervise testing, adjusting and balancing of building environmental systems to produce the design objectives or optimum system performance. For TABB Certification purposes, a Supervisor is the person who, while employed by a TABB Certified Contractor, is responsible and accountable for overseeing, coordinating and ensuring that projects are performed by TABB Certified Technicians in accordance with TABB standards (including the ICB Code of Conduct and the TAB General Rules). Measurements recorded in this report are in accordance with the SMACNA 1 TABB HVAC Systems, Testing, Adjusting and Balancing manual. f Certr ertific, No ANSI , v o (ANSI Anthony Kompelien Anthony Kompelien TAF F Technician TASB Supervisor 2H875224T 788752248 Ncember 31; 2014 Derember 31, 2 11<1 ininc0d, '.2aY3 a°Y~ ~ ~i Sa ] 1.-~2G3^ 4 5 8AZ Peter Korzenowski T604 7120 0 Q ~ a SUpesviSor 10)728 Rfo alid Unless Signe Exp. 12131 /2014 TABB Certified "The Professional's Choice" Page 2 TABB QUALITY ASSURANCE PROGRAM BACKGROUND TABB seeks to ensure the integrity of its certification program by: (a) setting eligibility criteria for TABB Certified Supervisors and TABB Certified Contractors, (b) establishing testing procedures for TABB Certified Supervisors, (c) requiring continuing education and continuous compliance with eligibility criteria for renewal of certification, and (d) periodically reviewing its recognition of technician certification. High quality work on the part of TABB Certified Technicians and TABB Certified Supervisors and TABB Certified Contractors ( TABB Professionals ) is essential to integrity of the TABB Certification Program. TABB offers this TABB Quality Assurance Program to help assure high quality work. By accepting TABB qualification or certification, every TABB Professional accepts the responsibilities or this Program. Quality Assurance Every customer of a TABB Certified Contractor shall be entitled to expect: (1) that testing, adjusting and balancing work by the contractor and its TABB Professionals will meet TABB standards; (2) that testing, adjusting and balancing reports provided to the customer will have been prepared by a TABB Certified Technician, and reviewed by a TABB Certified Supervisor; and (3) that the report(s) will include measurements taken accurately with the date and mode of operation of the systems. TABB 8403 Arlington Boulevard Fairfax, VA 22031 Phone - (703) 299-5646 Fax - (703) 683-7615 TABB Certified "The Professional's Choice" Page 3 INSTRUMENT CALIBRATION REPORT INSTRUMENT MODEL MANUFACTURER SERIAL NUMBER CALIBRATION DATE Rotating Measuring Instrument PLT-5000 _ Mitchell Instruments B12A8503P 12/02/13 Temperature Measuring Instrument ADM-870C Shortridge M12072 01/21114 Electrical Measuring Instruments 117 Fluke 18561871 01/15114 322 Fluke 17830473 01/15/14 Air Pressure Measuring Instrument ADM-870C Shortridge M12072 01/21114 Air Velocity Measuring Instrument ADM-870C Shortridge M12072 01/21/14 Hydronic Pressure Measuring Instrument HM-670 Alnor 71133088 01/15/14 0 to 300 psi Humidity Measuring Instrument MITCT917 _ Mitchell Instruments 100610809 01/20/14 TABB Certified "The Professional's Choice" Page 4 Premier Test & Balance Air Handling Unit Test Data Project: Sampsonite System: RTU 940-1 Premier Job Number: 1237 Technician: Tony Kompelien Completion Date: 7/30/14 System Scheduled Data Model number: LCH072H4BJ2G Serial number: 5613LO4507 Manufacturer: Lennox Outlet Total CFM: 2,500 Total Design CFM: 2,500 Min.Outside Air CFM: 480 Fan Static Pressure: 1.00 E ui ment Location: Roof Performance Data Description Scheduled 1 Submittal Data Actual Field Measurements Motor HP:. 2.00 2.00 Motor RPM: 1755 1755 Motor Hertz: 60 60 Motor Service Factor: 1.15 1.15 Motor Phase: 3 3 Motor Voltage: 460 476 476 476 Motor Amperage: 2.9 2.6 2.6 2.6 Motor BHP: 1.86 Fan RPM: 810 Static Pressure Data Component Static Pressure Pressure Pressure In Out Rise 1 Drop Total Fan: -0.18 0.48 Rise 0.66 Airflow Measurements Supply Air Opening Area Size K Design Final Reading Preliminary Reading No. Served Factor Veloci CFM Velocity CFM % Velocity CFM 1 Stockroom 14' 1.07 701 750 743 795 106% 974 1042 2 Sales 18" 1.77 990 1750 1002 1771 101% 1184 2092 Total 2500 2566 103% 3134 Minimum Outside Air Size K Design Final Reading Prelimina Reading Factor Velocity CFM Velocity CFM % Velocity CFM Total 30x19 3.96 121 480 120 475 99% 32 127 Remarks: a) b) C) d) e) TABB Certified "The Professional's Choice" Page 6