Loading...
3925 Eagan Outlets Pkwy - Ste 805 - Robert Graham17135 W. 10 Mile Road 380 Northwest Highway 8401 73rd Ave North Suite 112 Suite 210 Suite E-8 Southfield, MI 48075 Des Plaines, IL 60016 Minneapolis, MN 55428 Phone (248) 559-5864 Phone (847)759-1800 Phone (763) 533-8882 ROBERT GRAHAM EAGAN, MINNESOTA AIR TESTING & BALANCING REPORTS ITB PROJECT #: MN2771 JOB NAME:ROBERT GRAHAM LOCATION:EAGAN, MINNESOTA I.T.B. PROJECT #:MN2771 DATE:9/14 THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. ICB/NEBB FIRM:INTERNATIONAL TEST & BALANCE INC. CERTIFIED BY:CHARLES BRUNER DATE:9/18/2014 THE HYDRONIC DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. ICB/NEBB FIRM :INTERNATIONAL TEST & BALANCE INC. CERTIFIED BY: DATE: SUBMITTED & CERTIFIED BY: INTERNATIONAL TEST & BALANCE, INC. NEBB CERTIFIED: CHARLES BRUNER SIGNATURE: DATE:9/18/14 CERTIFICATION EXPIRATION DATE: CERTIFICATION INTERNATIONAL TEST & BALANCE, INC. 8401 73rd Avenue, N., Suite E-8 Minneapolis, MN 55428 Voice (763) 533-8882 Fax (763) 533-8933 PROJECT: ROBERT GRAHAM LOCATION: EAGAN, MN DATE: 9/18/2014 CONTACT: Charles Bruner Roof Top Unit PROJECT #: MN2771 Test Date: September 17, 2014 SYSTEM/UNIT: RTU-01 AREA: SPACE #805 Tested By: Charles Bruner Unit Data Unit Manufacturer LENNOX Type DRAW-THRU Blade Type FC Class NOT LISTED Filter Data 4-20x25x2 Starter Data Starter Size N/A Heater Size N/A Heater Rating N/A Amps Test Data Design System Total CFM 3400 CFM Actual System Total CFM 3371 CFM Design Return Air CFM N/A CFM Actual Return Air CFM 2744 CFM Design Outdoor Air CFM 680 CFM Actual Outdoor Air CFM 627 CFM Design Outlet Total CFM 3400 CFM Actual Outlet Total CFM 3371 CFM Design T.F.S.P.1" wc ESP in. wc Design Fan RPM N/A RPM Design Motor RPM 1755 RPM Design Voltage/Phase 460/3 VOLTS Actual Voltage/Phase 482-482-483 VOLTS Design Amperage 2.9 AMPS Actual Amperage 3.3-3.3-3.2 AMPS Design Brake Horsepower 3.75 BHP Actual Brake Horsepower 2.36 BHP Design Hertz 60 HZ Actual Hertz 60 HZ O.A. Damper Position 15 % R.A. Damper Position 85 % S.P. Set Point N/A Motor Data Motor Manufacturer INTERLINK Motor Serial #N/A Frame Size 56HZ Service Factor 1.15 Horsepower 2 Sheave Data Motor Sheave 1VP34 Motor Sheave OD 3.15 in. Motor Bore Size 7/8 in. Fan Sheave MA58 Fan Sheave PD 5.50 in. Fan Sheave OD 5.75 in. Fan Bore Size 1 in. Shaft Centers 21 1/2 in. Belt Quantity 1 International Test & Balance, Inc. Page 1 of 4 PROJECT: ROBERT GRAHAM LOCATION: EAGAN, MN DATE: 9/18/2014 CONTACT: Charles Bruner Roof Top Unit PROJECT #: MN2771 Test Date: September 17, 2014 SYSTEM/UNIT: RTU-01 (Cont.) AREA: SPACE #805 Tested By: Charles Bruner RTU-01 Supply Outlet Summary AK Factor % Final Diff. Final Airflow Prelim Airflow Design Airflow InstrumentSize Outlet Type Area ServedSystem / Unit RETAIL SAD12x12Outlet-01 1.00191109HOOD1750 RETAIL SAG18x6Outlet-02 0.54357110RVA3250 RETAIL SAG8x8Outlet-03 0.31163109RVA1500 RETAIL SAG18x6Outlet-04 0.54349107RVA3250 RETAIL SAG16x6Outlet-05 0.47245109RVA2250 RETAIL SAG8x8Outlet-06 0.31156104RVA1500 RETAIL SAG18x6Outlet-07 0.5429390RVA3250 RETAIL SAG16x6Outlet-08 0.4720390RVA2250 RETAIL SAG18x6Outlet-09 0.5431095RVA3250 RETAIL SAG16x6Outlet-10 0.4722399RVA2250 BACK STORAGESAG18x6Outlet-11 0.5428796RVA3000 BACK STORAGESAG18x6Outlet-12 0.5427391RVA3000 BACK STORAGESAG8x6Outlet-13 0.2313590RVA1500 FITTING ROOMSSAG8x6Outlet-14 0.2318693RVA2000 ----- 3,400 - 3,371Totals : 99 % 17-Sep-14 THE FILTERS HAD TO BE TAKEN OUT BECAUSE OF BEING DIRTY AND PLUGGED RTU-01 Charles Bruner* Notes International Test & Balance, Inc. Page 2 of 4 PROJECT: ROBERT GRAHAM LOCATION: EAGAN, MN DATE: 9/18/2014 CONTACT: Charles Bruner Fan Unit PROJECT #: MN2771 Test Date: September 17, 2014 SYSTEM/UNIT: EF-01 AREA: RESTROOM Tested By: Charles Bruner Unit Data Fan Manufacturer GREENHECK Fan Model Number SP-B110 Starter Data Starter Manufacturer N/A Starter Model No.N/A Starter Size N/A Rated Amps N/A Amps Required Amps N/A Amps Test Data Design Airflow 100 CFM Actual Airflow 122 CFM Design RPM 950 RPM Actual RPM 950 RPM Motor Volts T1-T2 120 Volts Motor Volts T2-T3 N/A Volts Motor Volts T1-T3 N/A Volts Motor Amps T1 N/A Amps Motor Amps T2 N/A Amps Motor Amps T3 N/A Amps Suction SP N/A in. wc Discharge SP N/A in. wc Motor Data Rated Airflow Capacity 100 CFM Motor Manufacturer Fasco Motor Frame Not Listed Motor RPM 950 RPM Motor Rated Volts 115 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.00 Amps Motor Service Factor N/A Brake Horse Power ? BHP Corrected FL Amps ? Amps Nominal Efficiency Not listed % Power Factor Not Listed Sheave Data Motor Sheave MFG Direct Drive Motor Sheave Model Direct Drive Motor Sheave Diam.OD Direct Drive Motor Sheave Bore Direct Drive Fan Sheave MFG Direct Drive Fan Sheave Model Direct Drive Fan Sheave Diam. OD Direct Drive Fan Sheave Diam. PD DIRECT DRIVE Fan Sheave Bore DIRECT DRIVE Number of Belts Direct Drive Belt Size Direct Drive Sheave Center Line Direct Drive 17-Sep-14 COULDN'T FIND A SPEED CONTROLLER AND NO ACCESS TO TAKE AMPS AND VOLTS EF-01 Charles Bruner 17-Sep-14 TOOK A READING ON A PLASTIC GRILLE WITH A HOOD EF-01 Charles Bruner * Notes International Test & Balance, Inc. Page 3 of 4 PROJECT: ROBERT GRAHAM LOCATION: EAGAN, MN DATE: 9/18/2014 CONTACT: Charles Bruner Fan Coil PROJECT #: MN2771 Test Date: September 17, 2014 SYSTEM/UNIT: ACU-01 AREA: DOOR CURTAIN Tested By: Charles Bruner Unit Data Unit Manufacturer REDD-I Filter Manufacturer NONE INSTALLED Filter Type N/A Filter Qty - S1 N/A Filter Size - S1 N/A Test Data Design Airflow 750 CFM Actual Airflow 862 CFM Design RPM NOT LISTED RPM Actual RPM N/A RPM Motor Volts T1-T2 287 Volts Motor Volts T2-T3 N/A Volts Motor Volts T1-T3 N/A Volts Motor Amps T2 N/A Amps Motor Amps T3 N/A Amps Design O/A N/A CFM Actual O/A N/A CFM Motor Data Motor Manufacturer Not Listed Motor Type Direct Drive Motor Frame N/A Motor HP Not Listed HP Motor RPM Not Listed RPM Motor Rated Volts 277 Volts Motor Phase 1 Motor Hertz 60 Hz Nominal Efficiency NOT LISTED % Power Factor NOT LISTED Sheave Data Motor Sheave MFG Direct Drive Motor Sheave Model Direct Drive Motor Sheave Diam.Direct Drive in. Motor Sheave Bore Direct Drive in. Fan Sheave MFG Direct Drive Fan Sheave Model Direct Drive Fan Sheave Diam.Direct Drive in. Fan Sheave Bore Direct Drive in. Number of Belts Direct Drive Belt Size Direct Drive Sheave Center Line DIRECT DRIVE in. 17-Sep-14 COULDN'T LOCATE A SPEED CONTROLLER ACU-01 Charles Bruner 17-Sep-14 WE HAVE TAKEN A VELGRID READING ON THE OPEN END DUCT 16x12 FOR 1.333 SQFT x 647 AFPM = 862 CFM ACU-01 Charles Bruner * Notes International Test & Balance, Inc. Page 4 of 4