Loading...
2133 River Valley Lane -71 ql-3.5-6- Use BLUE or BLACK Ink 7 ----------------- / ( 'gwI For Office Use My 1'``�' ���� I Permit#: � of Eatan 1 'G RECEIVED °I. I Permit Fee: ' 3830 Pilot Knob Road I Ira Eagan MN 55122 r�A 106 Date Received: j Phone: (651)675-5675 I I Fax: (651)675-5694 1 Staff�J6 2016 RESIDENTIAL BUILDING PERMIT APPLICATION1;` Date: 1/16/2016 site Address: 2133 River Valley Lane Unit#: CalAtlantic Homes 952-229-6008 E A, Name: Phone: aRsd 7599 Anagram Drive, Eden Prairie, MN 55344 �aRtne# ��� Address/City/Zip: g Applicant is: Owner V( Contractor Multi-family esidence '' tt �C �` " ��1OVr' Description of work: y lf7t J Fj,(X,� �- '� t � $170,000 Construction Cost. Multi-Family Building: (Yes V /No Company: CalAtlantic Homes contact: Deb Bosley Address: 7599 Anagram Drive city: Eden Prairie ontractc State: MN Zip: 55344 Phone: 952-229-6008 Email: Deb.BOSley @calatl.com LLi n License#: BC700385 Lead Certificate#: If the project is exempt from lead certification, please explain why: The building was constructied after 1978. COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? Yes No If yes, date and address of master plan: 3999-4007 River Valley Way Licensed Plumber: Elander Mechanical, Inc. Phone: 952-445-4692 Mechanical contractor: Elander Mechanical, Inc. Phone: 952-445-4692 Sewer&water Contractor: Miller Brothers Exvacating Phone: 763-420-9170 Fire Suppression Contractor: Fire Suppression Service, LLC Phone: 763-277-8960 COTE;!'lay► dIpaQrt docuat you st f P �xda f fr r Qf ��� the in r a ro� be i ssi� �lItA "our prove sp int r sc� �„ at wow perrr� t(fre t eoncru th the ;ere_ tle secrets. 5 AU la CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. x I co , x Applicant's Printed Name V Applicant's Signature Page 1 of 3 . OAbT WRITE BELOW THIS LINE SUB TYPES Foundation _ Fireplace _ Porch (3-Season) _ Exterior Alteration (Single Family) Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration (Multi) _ Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous —X 01 of�Plex _ Lower Level _ Pool _ Accessory Building WORK TYPES New _ Interior Improvement _ Siding _ Demolish Building* Addition _ Move Building _ Reroof _ Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION Valuation I Occupancy MCES System Plan Review Code Edition Xhl SAC Units (25% 100%_) Zoning City Water Cens s Code Stories Booster Pump #of Units Square Feet PRV #of Buildings Length — Fire Suppression Required Type of Construction _ Width LJ I REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final/C.O. Required Footings (Addition) Final/ No C.O. Required Foundation HVAC_Gas Service Test Gas Line Air Test Roof:_Ice &Water _Final Pool: Footings _Air/Gas Tests _Final Framing Drain Tile Fireplace: Rough In _Air Test Final Siding:_Stucco Lath(5�"S—tone Lath _Brick Insulation Windows Sheathing Retaining Wall: _ Footings_ Backfill_Final Sheetrock Radon Control Fire Walls Fire Suppression: _Rough In_Final Braced Walls Erosion Control Shower Pan Other: Reviewed By: tj' , Building Inspector RESIDENTIAL FEES / y ,, � 1 Base Fee G L'( � A t° e J{ Surcharge Plan Review MCES SAC City SAC f ` ( 1 Utility Connection Charge S&W Permit& Surcharge 3 t Treatment Plant L J/ j Copies 2 TOTAL ,., ge2of3 New Construction Energy Code Compliance Certificate Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution panel - Date Certificate Posted COPY OF THIS DOCCUMENT WILL BE POSTED ON THE PLENTUM OF FURNACE 1/14/2016 Mailing Address of the Dwelling or Dwelling Unit: city: U APT N T I C 2133 River Valley Lane Eagan Name of Residential Contractor: MN License Number HOMES CalAtlantic Homes BC700385 THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply X Passive(No Fan) Active(With fan and monometer Z or other system monitoring C device a ° y Location(or future location)of Fan: co a T 3 = E a N IF fan is required;Attic ° °- —O ° a m m _ iu N C ° In N O d LL V ° Insulation Location ° Z m a O W m ° o' o' E E 7 a�i s 3 C N N ° z° LL U_ '° u- (R E Other Please Describe Here Below Entire Slab X Foundation Wall R-15 X R402.2.8,Exception;a.R-10-by plan Perimeter of Slab on Grade X Rim Joist(1 st Floor) R-20 x Rim Joist(2nd Floor+) R-20 X Wall R-21 X Ceiling,flat R-49 I I X Ceiling,vaulted R-49 X Bay Windows or cantilevered areas R-30 X Floors over unconditioned area R-38 X Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: 10.29 X I Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 10.32 JR-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Not required per mech.code Fuei Type NATURAL GAS ELECTRIC ELECTRIC Passive Manufacturer LENNOX RHEEM LENNOX X Powered Interlocked with exhaust device. Model ML193UH045XP24 PROE502RH91 13ACXN018 Describe: Input in 44000 Capacity in 50 Output 1.5 Other,describe: Rating or Size BTU&: Gallons: n Tons: AFUE or 93 SEER ]13 Location of duct or system: Efficiency Residential Load I Heating Loss Heating Gain cooling Load ERV in Mechanical Room Calculation 139466 115887 118383 Cfm's "round duct OR MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech.code Select Type Passive 1Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: I Other,describe: Energy Recover Ventilator(ERV)Capacity in cfms: Low: 150 High: 1140 Location of duct or system: 13alanced Ventilation capacity in cfms: Mechanical room Location of fan(s),describe: Cfm's Capacity continuous ventilation rate in cfms 6" "round duct OR metal duct Total ventilation(intermittent+continuous)rate in cfms " i i - - wr>ightsoft- Component Constructions Job: Date: 2015 Entire House By: Elander Mechanical Inc Plan: FREMONT 700 valley Industrial Circle South,Shakopee.MN 55379 Phone:952-445-4692 Fax:952-496-2092 - For: Ryland Homes Location: Indoor: Heating Cooling Minneapolis-St Paul Int`I Arp, MN, US Indoor temperature (°F) 70 72 Elevation: 837 ft Design TD (°F) 85 16 - Latitude: 45°N Relative humidity{%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 54.5 37.9 Dry bulb(°F) -15 88 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insui R Htg HTM Loss Cig HTM Gain Walls ft' Btuhpt?'F ft?'FtBtuh Bluhhl' Btuh 8luhtlt' Bluh 12F-Osw:Frm wall,vni ext,r-21 cav ins,1/2"gypsum board int n 782 0.065 21.0 5.52 4321 1.12 877 fnsh,2"x6"wood frm a 317 0.065 21.0 5.52 1753 1.12 356 s 709 0.065 21.0 5.52 3917 1.12 795 w 464 0.065 21.0 5.53 2562 1.12 520 all 2272 0.065 21.0 5.53 12552 1.12 2547 Partitions 12F-Osw:Frm wall,vni ext,r-21 cav ins,1/2"gypsum board int 192 0.065 21.0 5.52 1061 0.64 123 fnsh,2"x6"wood frm Windows 61A:vinyl Window,NFRC rated(SHGC=0.32) a 107 0.290 0 24.6 2633 34.5 3680 s 73 0.290 0 24.6 1799 19.5 1423 w 132 0.290 0 24.6 3252 34.5 4546 all 312 0.290 0 24.6 7684 31.0 9649 Doors 11JO:Door,mtl fbrgl type w 20 0.600 6.3 51.0 1040 17.1 348 Ceilings Std Ceiling R-49:Std Ceiling,R-49 932 0.020 49.0 1.70 1584 1.04 968 Floors 20P-38c:Fir floor,frm flr,12"thkns,carpet flr fnsh,r-38 cav ins, 504 0.030 38.0 2.55 1285 0.36 181 gar ovr 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 61 1.180 0 100 6104 0 0 2015-Jun-24 D7:14:15 F wrightsoft' Right-Suite®Universal 2012 12.1.06 RSU13410 Page 1 ACCA...ardkoesktopiHeat Losses 20131Ryiand Fremont.rup Caic=MJ8 Front Door faces: N LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: wts 3 >>G- cv-dow DATE OF SURVEY: LATEST REVISION: L YQ � O z a DOCUMENT STANDARDS fy 0 0 • Registered Land Surveyor signature and company ❑ ❑ • Building Permit Applicant .-� D ❑ • Legal description '0' 0 0 • .Address 0 0 • North arrow and scale ❑ ❑ • House type(rambler,walkout,split w/o,split entry, lookout,etc.) 0 ❑ • Directional drainage arrows with slope/gradient% 'R 0 0 • Proposed/existing sewer and water services&invert elevation ❑ 0 • Street name ❑ ❑ • Driveway(grade&width-in R/W and back of curb,22' max.) 0 z 0 • Lot Square Footage ❑ .0 ❑ • Lot Coverage ELEVATIONS Existing ❑. ❑ Property corners 0 D Top of curb at the driveway and property line extensions ❑ 12' ❑ Elevations of any existing adjacent homes X ❑ 0 Adequate footing depth of structures due to adjacent utility trenches ,.9' ❑ ❑ Waterways (pond,stream,etc.) Pr000sed �° ❑ ❑ Garage floor ❑ �6 D • Basement floor ," 0 0 • Lowest exposed elevation(walkout/window) ❑ 0 • Property comers ❑ 0 • Front and rear of home at the foundation PONDING AREA(if applicable) ❑�' D Easement line ❑ ❑ NWL ❑ ;y ❑ • HWL ❑ 0 • Pond#designation ❑ xi` 0 • Emergency Overflow Elevation 0 ,e( ,,qq • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ❑ ❑ • Lot lines/Bearings&dimensions -,ff 0 0 • Right-of-way and street width(to back of curb) !0' 0 0 • Proposed home dimensions including any proposed decks, overhangs greater.than 2',porches, etc. (i.e. all structures requiring permanent footings) --� 0 ❑ • Show all easements of record and any City utilities within those easements ❑ 0 • Setbacks of proposed structure and sideyard setback of adjacent existing structures 0 0 • Retaining wall requirements: Reviewed By: A Date G:/FORMS/Building Permit Application Rev.11-26-04 Located in the NE 1/4 of N Certificate of Survey for. Sec. 19, Twp. 27, Rge. 23 3:1 Maximum sl® s CalAtlantic Homes ar ``r, y E�I'i g Wall Will Townhome Address: Be y equir8d 2139 - 2133 River Valley Lane, Eagan, MN Townhome Model: � � Fremont F, Ontario H, Ontario E, Fremont E JJ p1 ' TC7 By 10' OFFSET EA.GAN ENG E1GlZll�i(; Ut;t�T BENCHMARK \� TOP OF SPIKE EL = 829.79 A\ PROVIDE AND MAINTA(N \ / \ STM INS T'PROTECT19N UNTIL � �� \ // r- ,17\ \ \ #INA L TURF 1� ESTABLISH" � � \ � \�'28.1 \\ \JJ ET 10' OFFSET X28.3 \ \ BENCHMARK _ _ l l °' d'W r TOP OF SPIKE p� o EL = 830.56 I V I I �� �� / i\�S ea \ \ \JJ \ 1 �c� 0�� /p Q ? \ 28.4 \ \ I It ul�l I l 11VJJ"' e �O' tp O�0 531,B Q 7 %O / / -141 A mod' \@@28.8�'0 \ \ \ F �o° o,A�O��, •Os 1'C �� \ \J S \ \ 32 0 5 m Qo I o \ \ Rim=827.6 x 830.1 09, 9s p5$ 33 \ W�+s X 829.9 (0 P\ > S gS� cv� r 0.58 >0 6�w` \ 29.4 A +o+ s \ ,'% g $ Z� �O �c>1 X07 00�� s \q2.5 \ /\ `� 34 dt8 CUT o V1 TC ,, BB 1.9 ` 32.0 °• �•' s S� ��' SO ' J ,' 830.9 �� \ COPM + 4 +ip d 9�, 11 / F `� 0� �\>p 830.9 \ \ ,a +so �oy$ 35 s�� , , 4 7C Be o SMH 6 834. x 6 'a 835.7 c> �.o �• � .Q {,+ 832.0 I 10' OFFSET O 0 0 6� TC Be 1 BENCHMARK L�l 00� s c�� -TOP OF SPIKE 832.9 EL = 831.37 836.0 4r8 LQ TC Be 33.2 \ / \ 836.4 834 6 k �\ 'x 834. ��-' 833.5 - - - - I I "q�YD Denotes Existing Hydrant 835.0 ^s�834.4 833.8 TC Be Retaining Wall r 83 .9 0 Denotes Existing Electric Box M i TV e-.• i Denotes Existing Television Box �� LEGAL DESCRIPTION: 0 Denotes Existing Telephone Box 00 00 Denotes Existing Light Pole Z fm Lots 32, 33, 34 and 35, Block 1, CEDAR GROVE Denotes Existing Service TOWNHOMES 1ST ADDITION, Dakota County, Minnesota o Denotes Existing Curb Stop x 000.o Denotes Existing Elevation Lots 32 and 33 Lots 34 and 35 x 900.0 Denotes Proposed Elevation PROPOSED BUILDING ELEVATIONS PROPOSED BUILDING ELEVATIONS Denotes Direction of Drainage - - Denotes Drainage & Utility Easement Lowest Floor Elevation: 831.0 Lowest Floor Elevation: 831.8 z (per recorded plat) Top of Foundation Elevation: 834.2 Top of Foundation Elevation: 835.0 -� Denotes Iron Monument Garage Slab Elevation (at door): 830.3 Garage Slab Elevation (at door): 831.1 Bearings shown are assumed NOTES: 1. Proposed building site grading is in accordance with the GRAPHIC SCALE grading plans prepared by Alliant Engineering, Inc., 0 10 20 40 last revised 7/28/15. 2. Contractor must verify sewer depth. ` 3. Driveways shown are for graphic purposes only. Final driveway; (IN FEET) design and location to be determined by owner/builder. 4. All building foundation dimensions shown on this survey (11x17 sheet) include exterior foundation insulation widths, if applicable. 1038 5711.008 BJS CalAtlantic Job No. 35050010721 - 35050010724 Refer to final building plans for foundation details. n I hereby certify to CalAtlantic Homes that this survey, plan or report was prepared by me or under my direct supervision Carlson and that I am a duly licensed land surveyor under the laws of the State of Minnesota. Dated this 11th day of January, 2016. McCain y y Signed: rlson McC Inc. ENVIRONMENTAL-ENGINEERING-SURVEYING 3890 Pheasant Ridge Drive NE, By Suite 100, Blaine, MN 55449 Thomas R. Balluff, L.S. eg. No. 40361 Phone: 763-489-7900 Fax: 763-489-7959 Peter J. Blomquist, L.S. Reg. No. 51676 n Use BLUE or BLACK Mk I For CNOW Um pw- C j Permit 0f bAn— n 1 3830 Pion Knob Road � Pemrit Fee: 1 Eagan MN U122 � I Des d• �J/��6 j Received: Phone;(661)67346676 t Fax(651)675-0114 MAR 1 71016 1 Sto. ! 2016 FIRE SUPPRESSION SYSTEMS PERMIT APPLICATION ,A P& 1rirRacP4*t.Tr' Ted ,l S91W 8; t ; CAL A'TLANTtL Phcr s� — Zj—tiGcn 1_ Ads t tyE 75,19 �NA6Qtq rte. "DR k<.. A is Contractor Owner �-- - Descriplion of work: NP604 /3 D Construction Cost 39`�©. Estimated Completion tie- Name Address t 0 eatxu5i'RIAL state. gyp- ,x,3'33 Phone: 7�,3_ Z'TT --89'rov Contact ...!R sc / ► 2 � s �'c�4.a �, c� FIRE PERMIT TYPE WORK TYPE Sprinkler SYslem(#of hea&?Z ANOW _Add Fire Pump _Standpipe Alterations _Remind Otiwr: Other: DESCRIPTION OF WOWC: Commercial !e Residential Educational FEES �t $60.00 Permit Fee Minimwn Contract Yakw$ 594 0. 00 x Al Surcharge=C.ontract Yalue x$0.0005 =$ Permit Few If the project valuation is over$1 rnNon,please call for Surcharge =$ $100.00 ResidenU Now(Mcludes She S=tN3f") _$ TOTAL FEE 314"Fire Meter $280.00 =$ FNe Meter =$. /00 r 00 TOTAL FEE *'Raqutremerds:2 ooaWleft sacs of and sv i Piicaftn s,cot sleek on materials and camponente to be used I haft apply for a Flre Suppression System pern*and admov ledge NW Nee Wmna%w Is complete and accrrale;OW Nee work will be In coi bNx.r nos wbh the ordlnerices and codes of Nw Cory of Eagan surd vrkh the Minnesota Buddk*Nir a Codes;"I understend this is not a permit,but only an appkadon for a perrrril,and work is not to start wlNrout a perms that the work will be In accordance vvkh the approved plan in the cave of work whM requIres a review and approval of plans. x �Jf�t 6A� x 41un 40<t -FOR OFFICE USE . . c Flow Alarm Drain Test Rat In 7-rip Pump Test Central Station F'�atl Conditions of Issuanev P.wn t;Reviewed by: tom; C!ty of aai Address: 2133 River Valley Lane Permit #: 134840 The following items were / were not completed at the Final Inspection on: 2/1 ?i /Q Final grade - 6" from siding Permanent steps — Garage Permanent steps — Main Entry Permanent Driveway \ic Permanent Gas Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn ).14v Trail / Curb Damage Porch Lower Level Finish Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: G:\Building Inspections\FORMS\Checklists 1 CityofEaall • 3830 Pilot Knob Road Eagan MN 55122 Phone: (651) 675-5675 Fax: (651) 675-5694 NOVi 2016 Use BLUE or BLACK Ink For Office Use / Permit*: 1 3 1 (K Permit Fee: Date Received: Staff: //--?-/6• 2015 RESIDENTIAL PLUMBING PERMIT APPLICATION Date: jo` 06C 1 tp Site Address: (eli-AeciVA _ /ri. . /. ,�; ,C.,41, Name:.Mlb. Company Inc dba Culligan Water Address: 16.01 50`h St East State:- Mn Zip: 55077 Phone: .651-451-2241 . Contact: William R Milbert Address / City / Zip: Suite #: License #: WC641376 City: Inver Grove Hgts.. Email: _ New Replacement _ Repair _ Rebuild _ Modify Space _Work in R.O.W. Description of work: RESIDENTIAL Water Heater _ Lawn Irrigation (. RPZ / PVB) Septic System Add Plumbing Fixtures (_ Main / _ Lower Level) _New Water Tumaround _ Abandonment XWater Softener RESIDENTIAL FEES: $60.00 Water Heater, Water Softener, or Water Heater and Softener (includes $5.00 State Surcharge) $60.00 Lawn Irrigation (includes $5.00 minimum State Surcharge) $60.00 Add Plumbing Fixtures, Septic System Abandonment, Water Turnaround* (includes $5.00 State Surcharge) *Water Turnaround (add $200.00 if a 5/8" meter is required) $115.00 Septic System New ($10.00 per as built) (includes County fee and $5.00 State Surcharge) TOTAL FEES $ 16.0 0 CALL BEFORE YOU DiG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. 'Call 48 hours before you -intend to digto receive locates of underground utilities www.aooherstateonecali.ora I hereby acknowledge that this information is complete and accurate; that the work will be In conformance with the ordinances and codes of the City of Eagan; that I understand this Is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accord pc wi, the approved plan in.th case of work Ich requires a review and approv I.of plans. . 4 X . X Applicant's Printed Na e Applicant's Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA151529 Date Issued:08/29/2018 Permit Category:ePermit Site Address: 2133 River Valley Lane Lot:35 Block: 1 Addition: Cedar Grove Townhomes 1st PID:10-16680-01-350 Use: Description: Sub Type:Residential Work Type:Alteration Description:Basement Fixtures Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary:PL - Permit Fee (miscellaneous)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Louis Garcia 2133 River Valley Lane Eagan MN 55122 Richfield Plumbing 8640 Harriet Ave S #100 Bloomington MN 55420 (952) 881-3355 Applicant/Permitee: Signature Issued By: Signature