4200 Dodd Rd - Test & Balance Report 2016-01-11 111MDC Mechanical Data Corporalion January 11, 2016 Trace Plumbing & Heating Attn: Trace 5005 90th Ave. N.E. Spicer, MN 56288 RE: Eagan Fire Station Trace, Please find attached a copy of the test and balance report for the above referenced project. If you have any questions, please don't hesitate to call me. Sincerely, So&'Wo#Wou (1r) Scott Hoffman MECHANICAL DATA CORPORATION SH/jt cc: MDC File — 16040 6407 Cecilia Circle • Bloomington, MN 55439 • 952-473-1176 • Fax 952-473-2630 111MDC Mechanical Data Corporation "Test and Balancing" The air distribution system(s) have been tested and balanced to be totally operational and within design tolerance by Mechanical Data Corporation Eagan Fire Station for Mechanical Contractor Trace Plumbing & Heating by Mechanical Data Corporation Bloomington, Minnesota Test Engineer Scott Hoffman Certificate of Professional Independence Associated Air Balance Council TBE #05-04-32 Date January 11, 2016 111MDC Mechanical Data Corporation CONCEPT THE The prime definition of air conditioning, as stated in the American Society of Heating, Refrigeration and Air Conditioning Engineers Guide, is the process of treating air so as to control simultaneously its temperature, humidity, movement, cleanliness, and final distribution to meet the requirements of the space to be conditioned. While each of the preceding air treatment processes individually contribute a specific function of producing human comfort or space conditioning, in practical application it is the coordinated action of all of these processes, each related to and influencing the others, that produces the final desired conditions. It is easy to see that if one or the other of these coordinated functions is not performing as it should, the final results of all will be affected. To produce this coordinated function is the basic and scientific function of the "Test and Balance Agency". Associated Air Balance Council 1518 K Street N.W. Washington, D.C. 20005 202-429-9440 Mechanical Data Corporation has been certified by the Associated Air Balance Council to be a true, independent testing and balancing agency. Mechanical Data Corporation has no financial ties or interplay with contractors, suppliers or designers. This enables us to remain unbiased professionals at all times. Mechanical Data Corporation has been certified under certification number 112146. Branden Johnson is a registered test engineer under certification number 05-04-32. 6407 Cecilia Circle - Bloomington, MN 55439 - 952-473-1176 - Fax 952-473-2630 —-.xxv,+ *v v' ': Pr s,«y;••n; „,y rx„ ,a• t�. ,�,••,P a �,oe+, " •«+ A b LA rgu� �'�,.! w} .�;yy•:*�+„y � r � Ai��i"t'4"� * 6a,.tt't rd 6 at m '+r '�' ,ff� #Y+a� Y� i ' £t, O��i �"d � �q'.y • y�1y$` ♦ 1 1 , 4 ..} , C' F Y , � r 1 � " p .•y, !: �e 11 f, r3�r,rte + r + f + U t{ • R-4 L+ rs fld f� ''`" Cd Cd 4�f {iP•,��y�N4 �•r� �jy C3 tj f f e ..+e'. C1 tier M4 +r 1 f f � + � f ♦ a ♦ .� e •� ♦ ,a•�:e. +#' +, .5'� •'+'��.,,!j �r" � a e .e � ,tea �.r�'' #� +• Yk • .,t+' ',' t4y�� ••�,�,•w,"•�4 �'m .f�,,,'4'+!, �� iw` ? 4r't %�9`���.� �/ =�"'.`s''��-...y"�.,. -.i.%\,. � �.z,�,.!'h`=rem% 'i d ti'c'das ':.•q ar'r'}j``, r��=4�✓ �v """..r�.;�,�`i"F`4., ;� ,,.�;, �. ``�"r' `�'Y`�''' Mechanical Data 001paratlon Test and Balance Report Review The following report wa produc d by: Scott Hoffman (Project Technician Signature) The following report w s review y: Branden Johnson (TBE Signature and stamp) 6 V � 777 7- 'j n . 0 d el n- MENIL 111MDC Mechanical Data corporation INSTRUMENTATION TEST EQUIPMENT INSTRUMENT MODEL SERIAL NO CAL DATE Fluke RMS DVM 8922A 4921050 NA Airdata ADM-860 M 011024 8/20/15 Multimeter Differential Barton 0 to 100" 12-0908 8/22/13 Water Meter Capture Hood EBT731 EBT731308009 2/17/15 Balometer Rotating Vane RVA801, A03168 10/14/14 Anemometer Rotating Vane RVA801 A03169 10/15/14 Anemometer ALL INSTRUMENTATION IS CALIBRATED PER THE MANUFACTURES RECOMMENDATIONS Page No. 1 of 10 Date: 1/11/2016 Mochanlca Data Oorparallon Member of Associated Air Balance Council CONSTANT VOLUME SUPPLY FAN TEST JOB NAME: EAGAN FIRE STATION SYSTEM: RTU -1 MAKE AAON I I MODEL RN-009 REQUIRED PRELIMINARY FINAL CFM 2,975 3,192 2,980 VFD 60 Hz 53 Hz 53 Hz FAN IN/OUT/TSP -/-/NA -.89/+.37/1.26 -.91/+.41/1.32 EXTERNAL S.P. 441.50 -.56/+.37/.93 -.58/+.41/.99 FILTER -/-/NA -.56/-.89/.33 (1) -.58/.91/.33 (1) COOLING COIL -/-/NA -.56/-.89/.33 (1) -.58/.91/.33 (1) FAN RPM Direct Drive Direct Drive Direct Drive MOTOR RPM 1,760 1,555 1,555 MOTOR VOLTAGE 230 230 230 MOTOR AMPERAGE 6,8 3.8 3.8 MOTOR HORSEPOWER 2 2 2 OUTSIDE AIR DAMPER 360 CFM (20% @) 744 CFM (14% @) 389 CFM POSITION NOTES: (1) SP taken across filter and coil. Page No. 2 of 10 Date: 1/11/2016 Meahanlap Dala CO/POIpiIOn Member of Associated Air Balance Council DIFFUSER AND GRILL TEST JOB NAME: EAGAN FIRE STATION SYSTEM: RTU - 1 ROOM OUTLET OUTLET REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 106 1-1 LD 1.0 500 500 322 322 507 507 105 1-2 LD 1.0 275 275 257 257 299 299 103 1-3 CD 1.0 375 375 469 469 392 392 103 1-4 CD 1.0 375 375 568 568 396 396 103 1-5 CD 1.0 375 375 599 599 357 357 103 1-6 CD 1.0 375 375 538 538 368 368 i 101 1-7 SD 1.0 600 600 344 344 552 552 102 1-8 CD 1.0 100 100 95 95 109 109 2975 3192 2980 i I i i I i I NOTES: I i i Page No. 3 of 10 AdIft Date: 1/11/2016 Mechanical Data Corporation Member of Associated Air Balance Council CONSTANT VOLUME SUPPLY FAN TEST JOB NAME: EAGAN FIRE STATION SYSTEM: RTU -2 MAKE AAON MODEL RQ-004 REQUIRED PRELIMINARY FINAL CFM 1,350 1,334 1,316 FAN IN/OUT/TSP -/-/NA -1.32/+.47/1.79 -1.40/+.59/1.99 EXTERNAL S.P. 441.25 -.86/+.47/1.33 -.90/+.59/1.49 FILTER -/-/NA -.86/-1.32/.46 (1) -.90/-1.40/.50 (1) COOLING COIL -/-/NA -.86/-1.32/.46 (1) -.90/-1.40/.50 (1) FAN RPM Direct Drive Direct Drive Direct Drive MOTOR RPM 1,760 1,503 1,503 MOTOR VOLTAGE 230 230 230 MOTOR AMPERAGE 7 4.6 4.5 MOTOR HORSEPOWER 1 1 1 OUTSIDE AIR DAMPER 200 CFM (20% @) 274 CFM (15% @) 202 CFM POSITION NOTES: (1) SP taken across filter and coil. 111MDC Page No. 4 of 10 Date; 1/11/2016 Mechanical Dafa corporation Member of Associated Air Balance Council DIFFUSER AND GRILL TEST JOB NAME: EAGAN FIRE STATION SYSTEM: RTU -2 ROOM OUTLET OUTLET REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 112 2-1 CD 1.0 215 215 343 343 226 226 112 2-2 CD 1.0 215 215 309 309 206 206 E 101 2-3 CD 1.0 360 360 216 216 332 332 (l) 101 2-3A CD 1.0 360 360 200 200 305 305 (l) 113 2-4 CD 1.0 100 100 125 125 104 104 111 2-5 CD 1.0 100 100 141 141 107 107 1350 1334 1316 i I i I I NOTES: (1) Due to space limitation, installed diffusers differ from HVAC layout. Diffusers delivering 88%of original design CFM. I i i I I i Page No. 5 of 10 111MD Date: 1/11/2016 Mechanical Data Corporation Member of Associated Air Balance Council EXHAUST FAN TEST JOB NAME: EAGAN FIRE STATION FAN NO. EF-1 EF-2 EF-3 EF-4 MANUFACTURER Cook Cook Cook Cook MODEL No. 165 ACE2 90 ACEH 90 ACEH 90 ACEH MOTOR HP 2.0 1/4 1/4 1/4 VOLTAGE 230 120 120 120 RATED AMPS 6.7 3.4 3.4 3.4 ACTUAL AMPS 4.9 .51 .60 .54 REQUIRED FAN RPM Variable Variable Variable Variable ACTUAL FAN RPM 1800 Direct Drive Direct Drive Direct Drive REQUIRED CFM 3520 200 200 200 ACTUAL CFM 3647 186 185 196 LOCATION App Bay 102 111 110 NOTES: Page No. 6 of 10 Date: 1/11/2016 iiii.WD. a Corporation Member of Associated Air Balance Council DIFFUSER AND GRILL TEST JOB NAME: EAGAN FIRE STATION SYSTEM: EXHAUST ROOM OUTLET OUTLET „K„ REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM EF-1 108 1-1 11x11 .84 435 365 403 339 446 375 108 1-2 11x11 .84 435 365 583 490 461 387 108 1-3 11x11 .84 435 365 715 601 475 399 108 1-4 11X11 .84 435 365 384 323 420 353 107 1-5 11 x17 1.30 396 515 (1) (1) 400 520 107 1-6 11x17 1.30 396 515 (1) (1) 421 547 107 1-7 11x17 1.30 396 515 (2) (2) 430 559 107 1-8 11x17 1.30 396 515 (2) 390 507 3520 3920 3647 E F-2 102 2-1 EG 1.0 200 200 186 18 6 186 186 EF-3 111 3-1 EG 1.0 200 200 238 238 185 185 EF-4 110 4-1 3.5x13.5 .33 606 200 945 312 595 196 NOTES: (1) D- 16 RND, K- 1.40, AV-812, CFM - 1137 (2) D - 16" RND, K- 1.40, AV-736 CFM - 1030 Page No. 7 of 10 Date: 1/11/2016 Maahanlcal Data Gorporallon Member of Associated Air Balance Council TRANSFER FAN TEST JOB NAME: EAGAN FIRE STATION FAN NO. TF-1 TF-2 MANUFACTURER Cook Cook MODEL NO. 100 SQN 100 SQN MOTOR HP 1/4 1/4 VOLTAGE 120 120 RATED AMPS 3.4 3.4 ACTUAL AMPS .55 1.13 REQUIRED FAN RPM Variable Variable ACTUAL FAN RPM Direct Drive Direct Drive REQUIRED CFM 500 700 ACTUAL CFM 506 746 LOCATION 104 109 NOTES: i f Page No. 8 of 10 Date: 1/11/2016 Machoniccl Dcic Corporoilon Member of Associated Air Balance Council DIFFUSER AND GRILL TEST JOB NAME: EAGAN FIRE STATION SYSTEM: TRANSFER FANS ROOM OUTLET OUTLET „K„ REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM TF-1 104 1-1 SD 1.0 500 500 680 680 506 506 2 TF- 109 F- SD 1.0 700 700 746 746 746 746 NOTES: Page No. 9 of 10 lddllllllh Date: 1/11/2016 Mechanical Data Corporation Member of Associated Air Balance Council MAKE UP AIR TEST JOB NAME: EAGAN FIRE STATION FAN NO. MAU - 1 MANUFACTURER AAON MODEL NO. RN-009 MOTOR HP 2.0 VOLTAGE 230 RATED AMPS 6.8 ACTUAL AMPS 4.8 REQUIRED FAN RPM 1170 ACTUAL FAN RPM Direct Drive REQUIRED SP 44.75 ACTUAL SP -.57/+.11/.68 REQUIRED CFM 3520 ACTUAL CFM 3405 (l) LOCATION App Bay NOTES: (1) Fan operating at 85% speed setting. 111MD Page No. 10 of 10 Aoft Date: 1/11/2016 Nleohanlaat Data Corporation Member of Associated Air Balance Council DIFFUSER AND GRILL TEST JOB NAME: EAGAN FIRE STATION SYSTEM: MAU -1 ROOM OUTLET OUTLET REQUIRED PRELIMINARY FINAL NO. NO. SIZE VEL CFM VEL CFM VEL CFM 108 M-1 13.25x13.25 1.22 598 730 823 1004 569 694 108 M-2 13.25x13.25 1.22 598 730 881 1075 580 708 107 M-3 13.25x17.25 1.59 648 1030 744 1183 621 987 107 M-4 13.25x17.25 1.59 648 1030 770 1224 639 1016 3520 4486 3405 NOTES: