Loading...
809 Great Oaks Tr - Supply & Return ResultsCertificate of CompletionCertificate of CompletionCertificate of CompletionCertificate of Completion Duct Sealing Performed For:Duct Sealing Performed For:Duct Sealing Performed For:Duct Sealing Performed For: Lofgren Heating, Randy 809 Great Oaks Trail Eagan, MN 55123 Overall Sealing ResultsOverall Sealing ResultsOverall Sealing ResultsOverall Sealing Results When we arrived, YOUR DUCTS HAD: 188.9 CFM of Leakage188.9 CFM of Leakage188.9 CFM of Leakage188.9 CFM of Leakage, equivalent to a This equals 113.3113.3113.3113.3 refrigerators full of air loss every hour. 35.7 Square Inch Hole35.7 Square Inch Hole35.7 Square Inch Hole35.7 Square Inch Hole After we finished, YOUR DUCTS HAVE: 27.4 CFM of Leakage27.4 CFM of Leakage27.4 CFM of Leakage27.4 CFM of Leakage, equivalent to a 5.2 Square Inch Hole5.2 Square Inch Hole5.2 Square Inch Hole5.2 Square Inch Hole This corresponds to a This corresponds to a This corresponds to a This corresponds to a 85.5% Reduction85.5% Reduction85.5% Reduction85.5% Reduction in in in in Duct Leakage.Duct Leakage.Duct Leakage.Duct Leakage. Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa. Aeroseal Case ID Date of Seal System Description Hardware 4006400640064006 8/24/20168/24/20168/24/20168/24/2016 Supply and ReturnSupply and ReturnSupply and ReturnSupply and Return Seal Description ReturnReturnReturnReturn Aeroseal Technician Michael and JimMichael and JimMichael and JimMichael and Jim HomeSealHomeSealHomeSealHomeSeal Duct Sealing Performed By:Duct Sealing Performed By:Duct Sealing Performed By:Duct Sealing Performed By: Home Performance Solutions 12253 Nicollet Ave. S. Burnsville, MN 55337 Phone: 952-7465200 Certificate of CompletionCertificate of CompletionCertificate of CompletionCertificate of Completion Duct Sealing Performed For:Duct Sealing Performed For:Duct Sealing Performed For:Duct Sealing Performed For: Lofgren Heating, Randy 809 Great Oaks Trail Eagan, MN 55123 Overall Sealing ResultsOverall Sealing ResultsOverall Sealing ResultsOverall Sealing Results When we arrived, YOUR DUCTS HAD: 538.2 CFM of Leakage538.2 CFM of Leakage538.2 CFM of Leakage538.2 CFM of Leakage, equivalent to a This equals 322.9322.9322.9322.9 refrigerators full of air loss every hour. 101.7 Square Inch Hole101.7 Square Inch Hole101.7 Square Inch Hole101.7 Square Inch Hole After we finished, YOUR DUCTS HAVE: 33.8 CFM of Leakage33.8 CFM of Leakage33.8 CFM of Leakage33.8 CFM of Leakage, equivalent to a 6.4 Square Inch Hole6.4 Square Inch Hole6.4 Square Inch Hole6.4 Square Inch Hole This corresponds to a This corresponds to a This corresponds to a This corresponds to a 93.7% Reduction93.7% Reduction93.7% Reduction93.7% Reduction in in in in Duct Leakage.Duct Leakage.Duct Leakage.Duct Leakage. Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Note: Duct Leakage results are calculated in Cubic Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard Feet per Minute (CFM) measured at a standard OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa.OPERATING PRESSURE of 25 Pa. Aeroseal Case ID Date of Seal System Description Hardware 4006400640064006 8/24/20168/24/20168/24/20168/24/2016 Supply and ReturnSupply and ReturnSupply and ReturnSupply and Return Seal Description SupplySupplySupplySupply Aeroseal Technician Michael and JimMichael and JimMichael and JimMichael and Jim HomeSealHomeSealHomeSealHomeSeal Duct Sealing Performed By:Duct Sealing Performed By:Duct Sealing Performed By:Duct Sealing Performed By: Home Performance Solutions 12253 Nicollet Ave. S. Burnsville, MN 55337 Phone: 952-7465200