Loading...
3305 Central Park Village Dr - Flow Dynamic Balancing (...0 FLOW DYNAMIC BALANCING Cover Page =),-).,os) PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 FIRM: Flow Dynamic Balancing,LLC PHONE: 612-578-9485 15025 Glazier Ave. FAX: 952-683-1289 Suite 106 Apple Valley, MN 55124 PROJECT: CPC FAIRVIEW CENTRAL PARK COMMONS DR DATE: 12/14/2016 PROJECT#: 1216 EAGAN,MN 55121 CONTACT: Jackson, Rande NOTES: 411 Flow Dynamic Balancing,LLC Name: Richard Yzermans • Company: Flow Dynamic Balancing, LLC Certification: TABB Supervisor Certification Code: TB 1004313S Expiration Date: March 31, 2018 Print Date: 12/13/2016 'N,a1 Certs`%c ,49 W3 Ar*ii"ii' 9c)) Richard Yzermans Flow Dynamic Balancing,LLC TABB Supervisor TB1004313S March 31,2018 Printed: 12/13/2016 O, sup FLOW DYNAMIC BALANCING Table Of Contents PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: > Rande Jackson PROJECT#: 1216 Table Of Contents 1 Roof Top Unit 1 1.1 RTU-01 1 1.2 RTU-01/FP VAV-01 2 1.3 RTU-01/FP VAV-02 2 1.4 RTU-01/FP VAV-03 ` 3 1.5 RTU-01/FP VAV-04 3 1.6 RTU-01/FP VAV-05 4 1.7 RTU-01/FP VAV-06 5 1.8 RTU-01/FP VAV-07 6 1.9 RTU-01/FP VAV-08 6 1.10 RTU-01/FP VAV-09 7 1.11 RTU-01/FP VAV-10 7 1.12 RTU-01 NAV-01 8 1.13 RTU-01 NAV-02 8 1.14 RTU-01 NAV-03 9 1.15 RTU-01NAV-04 9 ilk 1.16 RTU-01 NAV-05 10 lip 1.17 RTU-01 NAV-06 10 1.18 RTU-01 NAV-07 11 1.19 RTU-01NAV-08 11 1.20 RTU-01 NAV-09 11 1.21 RTU-01NAV-10 12 1.22 RTU-0INAV-11 12 1.23 RTU-01NAV-12 13 1.24 RTU-01 NAV-13 13 1.25 RTU-OINAV-14 14 1.26 RTU-01NAV-15 14 1.27 RTU-01NAV-16 15 1.28 RTU-02 15 1.29 RTU-02/FP VAV-01 16 1.30 RTU-02/FP VAV-02 16 1.31 RTU-02/FP VAV-03 17 1.32 RTU-02/FP VAV-04 18 1.33 RTU-02/FP VAV-05 18 1.34 RTU-02/FP VAV-06 19 1.35 RTU-02/FP VAV-07 19 1.36 RTU-02/FP VAV-08 20 1.37 RTU-02/FP VAV-09 21 dik 1.38 RTU-02/FP VAV-10 21 1.39 RTU-02/FP VAV-11 22 1.40 RTU-02NAV-01 22 Flow Dynamic Balancing,LLC (,_ FLOW DYNAMIC BALANCING i Table Of Contents PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 1.41 RTU-02NAV-02...;.. ...... .. ......... 23 1.42 RTU-02NAV-03 24 1.43 RTU-02NAV-04 25 1.44 RTU-02NAV-05 25 1.45 RTU-02NAV-06 26 1.46 RTU-02NAV-07 26 1.47 RTU-02NAV-08 27 2 Fan Unit 28 2.1 EF-01 28 2.2 EF-02 30 2.3 TF-01 31 2.4 TF-02 32 3 Calibration Data Sheet.pdf 33 4 ABBREVIATIONS REPORT.pdf 34 • • Flow Dynamic Balancing,LLC tf, FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01 Tested By: Rick Yzermans AREA: ROOF Date: 12/14/2016 ti' O ` } Unit Manufacturer AAON RTU-01/Supply Fan Unit Model Number RN-070-3-0-EA09-3D9- Motor Manufacturer BALDOR Unit Serial Number 201608-BNGY55930 Motor Frame 256T RTU-01/Filter Bank Motor HP 20 HP Filter Manufacturer AIRGUARD Motor RPM 1760 RPM Filter Type PLEATED Motor Rated Volts 460 Volts Filter Qty-S1 24 Motor Phase 3 Filter Size-S1 12X24X4 Motor Hertz 60 Hz r Motor FL Amps 23.5 Amps. ' . .. Tp � Motor Service Factor 1.15 Design Airflow 22000 CFM Brake Horsepower 18.27 BHP Actual Airflow 22686 CFM Corrected FL Amps 26.26 Amps Design Outside Airflow 6050 CFM Nominal Efficiency 0.93% Actual Outside Airflow 6171 CFM Motor Power Factor 0.86% Design Return Airflow 15950 CFM Actual Return Airflow 16515 CFM RTU-01/SuooIv Fan RTU-01/Suonly Fart Design RPM 1395 RPM Motor Sheave Model DIRECT DRIVE Motor Volts T1-T2 412 Volts Motor Volts T2-T3 411 Volts Motor Volts T1-T3 412 Volts Fan SPIn -0.12 in.we Motor Amps T1 23.90 Amps Fan SP Out 0.87 in.wc Motor Amps T2 23.80 Amps 0/A Damper Position 32% Motor Amps T3 24.00 Amps R/A Damper Position 68% Design Hertz 60.0 HZ Actual Hertz 51.0 HZ Static Pressure St.Pt. 1.20 in.wc Log: RTU-01 12/12/2016 Travis Wiskur OA 32X96 AREA 21.3 6171 CFM 4) Flow Dynamic Balancing,LLC Page 1 of 35 FLOW DYNAMIC BALANCING 110 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/FP VAV-01 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 VAV Address 1-1 Design Max Airflow 1420 CFM Box Inlet Size 12 Actual Max Airflow 1405 CFM K Factor 1.20 Min Design CFM 430 CFM Actual Min Airflow 412 CFM Design Fan Airflow 800 CFM Actual Fan Airflow 750 CFM Total Heating Cfm Design 1230 CFM Total Heating Cfm Actual 1162 CFM RTU-01/FP VAV-01 Supply Outlet Summary ye4etm IUnit: Type Fad ! A r k � Outlet-01 LN 8 1.00 HD 125 195 156 132 106 Outlet-02 LN 8 1.00 HD 125 200 160 129 103 Outlet-03 LN 8 1.00 HD 135 160 119 135 100 Outlet-04 LN 8 1.00 HD 135 165 122 139 103 Outlet-05 LN 8 A 1.00 HD 210 230 110 202 96 Outlet-06 LN 8 1.00 HD 180 145 81 167 93 Outlet-07 LN 8 1.00 HD 165 220 133 166 101 Outlet-08 LN 8 1.00 HD 165 215 130 173 105 Outlet-09 LN 8 1.00 HD 180 140 78 162 90 SYSTEM/UNIT:RTU-OI/FP VAV-02 Tested By: RickYzermans AREA: CEILING Date: 12/12/2016 VAV Address1-2 Design Max Airflow 985 CFM Box Inlet Size 10 Actual Max Airflow 988 CFM K Factor 0.96 Min Design CFM 300 CFM Actual Min Airflow 287 CFM Design Fan Airflow 525 CFM Actual Fan Airflow 583 CFM Total Heating Cfm Design 825 CFM Total Heating Cfm Actual 870 CFM Log: RTU-01/FP VAV-02 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU y-011//FP"VAV-02 Supply Outlet Summary Outlet-01 LN 8 1.00 HD 205 270 132 216 105 Outlet-02 LN 8 1.00 HD 260 85 33 270 104 Outlet-03 LN 8 1.00 HD 260 350 135 267 103 Outlet 04 LN 8 1.00 HD 260 265 102 235 90 iiayktqcKe, Flow Dynamic Balancing,LLC Page 2 of 35 FLOW DYNAMIC BALANCING Roof Top Unit PROJECT: - CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/FP VAV-03 Tested By: Rick Yzermans AREA:CEILING Date: 12/12/2016 VAV Address 1-3 Design Max Airflow 1200 CFM Box Inlet Size 12 Actual Max Airflow 1230 CFM K Factor 1.14 Min Design CFM 360 CFM Actual Min Airflow 349 CFM Design Fan Airflow 600 CFM Actual Fan Airflow 671 CFM Total Heating Cfm Design 960 CFM Total Heating Cfm Actual 1020 CFM Log: RTU-01/FP VAV-03 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-03 Supply Outlet Summary Systemlt t" Dint f y��I A ' i sl# w Outlet-01 LN 8 1.00 HD 190 190 100 195 103 Outlet-02 LN 8 1.00 - HD 190 250 132 179 94 SOutlet-03 LN 8 1.00 HD 190 235 124 193 102 Outlet-04 LN 8 1.00 HD 190 { 195 103 208 109 Outlet-05 SAD 6 1.00 HD 60 104 173 62 103 Outlet-06 SAD 6 1.00 HD 60 100 167 64 107 Outlet-07 SAD 8 1.00 HD 120 128 107 128 107 Outlet-08 SAD 8 1.00 HD 200 187 94 201 101 SYSTEM/UNIT: RTU-01/FP VAV-04 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 VAV Address 1-4 Design Max Airflow 340 CFM Box Inlet Size 8 Actual Max Airflow 335 CFM K Factor 0.97 Min Design CFM 100 CFM' Actual Min Airflow 99 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 657 CFM Total Heating Cfm Design 415 CFM Total Heating Cfm Actual 756 CFM Log: RTU-01/FP VAV-04 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU--01//F.Pr�VAV-04 Supply Outlet Summary SOutlet-Outlet-0201 LNLN� 88 1.h` 1.0000 HDHD 170170 245 230 135144' 165 1970 00 Flow Dynamic Balancing,LLC Page 3 of 35 C___ FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/FP VAV-05 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016. t #'Da VAV Address 1-5Design Max Airflow .. � 530 CFM Box Inlet Size 8 Actual Max Airflow 539 CFM K Factor : 0.84' Min Design CFM 160 CFM Actual Min Airflow 148 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 628 CFM Total Heating Cfm Design 475 CFM Total Heating Cfm Actual 776 CFM Log: RTU-01/FP VAV-05 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-05 Supply Outlet Summary Sy M/1-10 t O t- S _001 t Type F A etta Outlet-01 LN 8 1.00 HD 180 160 89 172 96 Outlet-02 LN 8 1.00 HD 180 135 75 186 103 ilikS Outlet 03 SAD 8 1.00 HD 170 175 103 181 106 w6 III Flow Dynamic Balancing,LLC Page 4 of 35 ' , (..._ FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT:RTU-01/FP VAV-06 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 - �, Y VAV Address 1-6 Design MaxAirflow 1230 CFM Box Inlet Size 10 Actual Max Airflow 1236 CFM K Factor 1.16 Min Design CFM 370 CFM Actual Min Airflow 381 CFM' Design Fan Airflow 625 CFM Actual Fan Airflow 721 CFM Total Heating Cfm Design 995 CFM Total Heating Cfm Actual 1102 CFM Log: RTU-01/FP VAV-06 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-06 Supply Outlet Summary �y ys# +/v-ft; h Ouu�f ti W �m�eeaa� '�a r j�� P {§i 1 Outlet-01 LN 8 1.00 HD 125 180 144A. 123 98 Outlet-02 LN 8 1.00 HD 125 170 136 118 94 Outlet-03 LN 8 1.00 HD 125 180 144 132 106 0 Outlet-04 LN 8 1.00 HD 125 . 140 112 122 98 Outlet-05 LN 6 1.00 HD 75 - 90 120 78 104 Outlet-06 LN 6 A 1.00 HD 50 75 150 53 106 Outlet-07 LN 8 A 1.00 HD 125 95 76 134 107 Outlet-08 LN 6 1.00 - HD 80 65 81 82 103 Outlet-09 SAD 8 A 1.00 HD A 200 110 55 200 100 Outlet-10 SAD 8 1.00 HD 200 ' 180 90 196 98 ,::ix.0 .*.:-,),---.2.,..;.i.,, -,,...;,,,,,.,,„t:':7,.:,c,,,-‘,....:.,,,:-:,,,,,,-,„-iii,,,,....71,,,,,,,-7..',..,,:-Z;,:ii".,;-,,,;`",,?!,.."..,,':',-.. . ' *-'1.--,';',",-,,t7' ::,:4'-''t.;-Tr:.71'.',;,':irl'-'!°:.,-2,cn-,,'',,,,e.....,,,,, ill Flow Dynamic Balancing,LLC Page 5 of 35 FLOW DYNAMIC BALANCING Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/FP VAV-07 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 Lt VAV Address 1-7 Design Max Airflow 1035 CFM Box Inlet Size 10 Actual Max Airflow 1000 CFM K Factor 0.94 Min Design CFM 310 CFM Actual Min Airflow 299 CFM Design Fan Airflow 520 CFM Actual Fan Airflow 651 CFM Total Heating Cfm Design 830 CFM Total Heating Cfm Actual 950 CFM Log: RTU-01/FP VAV-07 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-07 Supply Outlet Summary Outlet-01 SAD 8 1.00 HD 205 194 95 201 98 Outlet-02• SAD 8 1.00 HD 205 192 94 194 95 Outl Outlet-et-0304 SAD 8 1.00 HD 205 184' 90 190 93 SAD 8 1.00 HD 205 189 92 199 97 Outlet-05 SAD 8 1.00 HD 215 210 98 216 100 SYSTEM/UNIT: RTU-01/FP VAV-08 Tested By: Rick Yzermans AREA:CEILING Date: 12/12/2016 VAV Address 1-8 Design Max Airflow 1145 CFM Box Inlet Size 10 Actual Max Airflow 1115 CFM K Factor 1.01 Min Design CFM 340 CFM Actual Min Airflow 327 CFM Design Fan Airflow 600 CFM Actual Fan Airflow 643 CFM Total Heating Cfm Design 940 CFM Total Heating Cfm Actual 970 CFM RTU-01/FP VAV-08 Supply Outlet Summary S dem/U e f Outlet-01 LN 8 1.00 HD 140 115 82 145 104 Outlet-02 LN 8 1.00 HD 140 95 68 129 92 Outlet-03 LN 8 1.00 HD 140 140 100 134 96 Outlet-04 LN 8 1.00 HD 140 135 96 138 99 Outlet-05 LN 8 1.00 HD 205 120 59 186 91 Outlet-06 LN 8 1.00, HD 205 135 66 211 103 Outlet 07 LN 8 1.00 HO 175 165 94 172 98 110 Flow Dynamic Balancing,LLC Page 6 of 35 FLOW DYNAMIC BALANCiNG • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/FP VAV-09 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 VAV Address 1-9 Design'Max Airflow 570 CFM Box Inlet Size 8 Actual Max Airflow 546 CFM K Factor 0.72 Min Design CFM 170 CFM. Actual Min Airflow 161 CFM Design FanAirflow 415 CFM Actual Fan Airflow 581 CFM Total Heating Cfm Design 585 CFM Total Heating Cfm Actual 742 CFM Log: RTU-01/FP VAV-09 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-09 Supply Outlet Summary �tem/UnFt ° Ot Size�t �m Tye R t Outlet-01 LN 8 1.00 HD 140 125 89 145 104 Outlet-02 LN 8 1.00 HD 130 90 69 125 96 ill Outlet-03 LN 8 1.00 HD 165 100 61 155 94 Outlet-04 LN 8 1.00 HD 135 100 74 121 90 Tot fls .vx; t v SYSTEM/UNIT: RTU-01/FP VAV-10 Tested By: Rick Yzermans AREA:CEILING Date: 12/12/2016 VAV Address 1-10 Design Max Airflow 480 CFM Box Inlet Size 8 Actual.Max Airflow 465 CFM K Factor 1.01 Min Design CFM 140 CFM Actual Min Airflow 137 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 672 CFM Total Heating Cfm Design 455 CFM Total Heating Cfm Actual - 809 CFM Log: RTU-01/FP VAV-10 12/12/2016 Rick Yzermans FAN ON LOW SPEED. RTU-01/FP VAV-10-Supply Outlet Summary Outlet-01 LN 8 1.00 HD160 145 91 150 94 Outlet-02 LN 8 1.00 HD 160 150 94 155 97 Outlet-03 LN 8 1.00 HD 160 155 97 160 100 • Flow Dynamic Balancing,LLC Page 7 of 35 FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-OINAV-01 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 a, `U ro ,n... ,P $ r VAV Address 1-1 Design Max Airflow 190 CFM Box Inlet Size 6 Actual Max Airflow 185 CFM, K Factor 1.10 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-01NAV-01 Supply Outlet Summary SXstemN:- Due l S 1 tr-' AK >I� � Pte. q); - 13c# ti `-ASI `' :; ,:, Outlet-01 SAD 8 1.00 HD 190 185 97 185 97' To#al§ .... `` - 90 185 .r fir,'.' .. r , w .... SYSTEM/UNIT: RTU-OINAV-02 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 ,' .,it f� ,. , ,..� r r P 3 s.i. . e.. _.. — ,s a. . pF r,.} : .:.v viz+, '..a VAV Address 1-2 Design Max Airflow 510 CFM S Box Inlet Size 8 Actual Max Airflow 539 CFM K Factor 0.98 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-02 Supply Outlet Summary Systemlit Ou# t �, e� i f Tye t ;4 , ¢ 1 Outlet-01 SAD 8 ,. 1.00 HD 120 83 69 127 106 Outlet-02 SAD 8 1.00 HD 130 115 88 143 110 Outlet-03 SAD 8 1.00 HD 130 131 101 137 105 Outlet-04 SAD 8 1.00 HD 130 173 133- 132 102 Totals 4 = _ . 1e r 5 III Flow Dynamic Balancing,LLC Page 8 of 35 FLOW DYNAMIC BALANCING i Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/VAV-03 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 VAV Address 13 Design Max Airflow 600 CFM Box Inlet Size 8 Actual Max Airflow 623 CFM K Factor 1.16 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-01/VAV-03 Supply Outlet Summary systemlUnit arae:,,,,,,,,_, :„_,,,,. . ,,,,,:,:::„,,,..,„,Tifti .,..,:::-- �t ,� 1$ s� x ...,x r.a..� ... an ..,, _, : r,,,, .: .. w. ,f-. t� ���-zWm.-I 4-'',4,::::=:k'..,-,,-,-,::4 Outlet-01 SAD ' j 6 1.00 HD 65 51 78 69 106 Outlet-02 SAD 8 1.00 ' HD 115 115 100 127 110 Outlet-03 SAD 6 1.00 HD 80 122 153 77 96 Outlet-04 SAD 6 1.00 HD 80 94 118 78 98 Outlet-05 SAD 6 1.00 HD 80 95 119 88 110 Outlet-06 SAD 6 1.00 HD 100 100 100 109 109 Outlet 07 SAD 6 1.00 HD 80 116 145 75 i 94 Totals .. ,, ,` .. , ., ,,. 4.00 '' 69Z 1 _. e a, ,.' :i • SYSTEM/UNIT: RTU-01NAV-04 Tested By: Travis Wiskur AREA:CEILING Date: 12/14/2016 .*.. .7: *. ix L ,.m x `Lx .?, .5 ,':;ii 'Yil li 4�'.ems`, VAV Address 1-4 Design Max Airflow 495 CFM Box Inlet Size 8 Actual Max Airflow 508 CFM K Factor 0.97 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-01NAV-04 Supply Outlet Summary $ys�nit O� i i ` A# : , � , Tye A + k Outlet-01 SAD 6 ' 1.00 HD 80 - 105 131 85 106 Outlet-02 SAD 6 1.00 HD 80 99 124 87 109 Outlet-03 SAD 6 1.00 HD 100 0 0 108 108 Outlet-04 SAD 6 1.00 HD 100 90 90 101 101 Outlet-05 SAD 6 1.00 HD 90 - 114 127 85 94 Outlet-06 SAD 6 1.00 HD 45 72 160 42 93 Totals .`. , , -....:„, .r z , . : • Flow Dynamic Balancing,LLC Page 9 of 35 i..,, (...._ FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: " EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-0INAV-05 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 t VAV Address 1-5 Design Max Airflow 755 CFM � � Box Inlet Size 10 Actual Max Airflow 764 CFM K Factor 1.04 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-05 Supply Outlet Summary SY l Outlet ° �-Lf C ► 1> E . irk T� F �r Y Outlet-01 SAD 8 1.00 HD 120 244 203 124 103 Outlet-02 SAD 8 1.00 HD 150 57 38 162 108 Outlet-03 SAD 8 1.00 HD 185 256 138 180 97 Outlet-04 SAD 8 1.00 HD 120 45 38 129 108 Outlet-05 SAD 8 1.00 HD 180 184 102 169 94 'Totals X. *_. o _ v . r.a 1 i:4 SYSTEM/UNIT:RTU-0INAV-06 Tested By: Rick Yzermans Aft AREA: CEILINGe: Dat 12/12/2016 NW Unit Qat 1 VAV Address 1-6 Design Max Airflow 270 CFM Box Inlet Size 8 Actual Max Airflow 270 CFM K Factor 1.00 Min Design CFM . 0 CFM Actual Min Airflow 0 CFM Log: RTU-01/VAV-06 12/12/2016 Rick Yzermans BOX IS FLUCTUATING AND WILL NOT SETTLE DOWN.12-12-2016 RTU-01 NAV-06 Supply Outlet Summary ',.System/U �., ° LXX/ ,:(..:10.4, 17-:,-06.1000:-:- nst T3 fl Fad #J, i !t 4 Outlet-01 LN 6 1.00 . HD� "� 45 �'45 100 45 100 Outlet-02 LN 6 1.00 HD 45 44 98 44 98 Outlet-03 LN 6 1.00 HD 45 43 96 43 _ 96 Outlet-04 SAD 8 1.00 HD 135 138 102 138 102 ';Tata ', , e .. . , ;:rt .t'x st:;; ,.. :l ill Flow Dynamic Balancing,LLC Page 10 of 35 FLOW DYNAMIC BALANCING Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01NAV-07 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 VAV Address 1-7 Design Max Airflow 125 CFM Box Inlet Size 4 Actual Max Airflow 128 CFM K Factor 1.16 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-07 Supply Outlet Summary type D F Af l A Outlet-01 SAD 8 1.00 HD 125 145 116 128 102 SYSTEM/UNIT:RTU-01/VAV-08 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 VAV Address 1-8 Design Max Airflow 150 CFM 4 Box Inlet Size 4 Actual Max Airflow 142 CFM K Factor 1.16 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-08 Supply Outlet Summary S r`stemlQnit Outlet LxWI ` e' er P "1 Type 1 i4=a� teii Outlet-01 SAD 8 1.00 HD 150 170 113 142 95 SYSTEM/UNIT: RTU-OINAV-09 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 tln fl VAV Address 1-9 Design Max Airflow 420 CFM Box Inlet Size 8 Actual Max Airflow 407 CFM K Factor 0.96 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-09 Supply Outlet Summary Sysfem/ t t �Slz L*WI Al{: € Type D then � r Outlet-01 SAD 8 1.00 HD 140 80 57 129 92 Outlet-02 SAD 8 1.00 HD 140 150 107 133 95 Outlet-03 SAD 8 1.00 HD 140 165 118 - 145 104 Flow Dynamic Balancing,LLC Page 11 of 35 (t. FLOW DYNAMIC BALANCING i Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-OINAV-10 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 VAV Address 1-10 Design Max Airflow 210 CFM Box Inlet Size 6 Actual Max Airflow 212 CFM K Factor 0.94 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-01NAV-10 Supply Outlet Summary Type Outlet-01 SAD 6 1.00 HD 105 85 81 102 97 Outlet-02 SAD 6 1.00 HD 105 100 95 110 105 SYSTEM/UNIT: RTU-01/VAV-11 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 411 Ute lata VAV Address 1-11 Design Max Airflow 1200 CFM Box Inlet Size 12 Actual Max Airflow 1190 CFM K Factor 1.08 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OI NAV-11 Supply Outlet Summary System/Unit UW I � Outlet-01 SAD 8 1.00 HD 200 260 130 203 102 Outlet-02 SAD 8 1.00 HD 200 280 140 208 104 Outlet-03 SAD 8 1.00 HD 200 260 130 211 106 Outlet-04 SAD 8 1.00 HD 200 135 68 201 101 Outlet-05 SAD 8 1.00 HD 200 210 105 183 92 Outlet-06 SAD 8 1.00 HD 200 215 108 184 TOW*: 12tQr X13 > .192 Flow Dynamic Balancing,LLC Page 12 of 35 ti. FLOW DYNAMIC B • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/VAV-12 Tested By: Travis Wiskur AREA: CEILING Date: 12/13/2016 Unit Data Term Box Test Data VAV Address 1-12 Design Max Airflow 250 CFM Box Inlet Size 6 Actual Max Airflow 246 CFM K Factor 0.85 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-12 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD _ 90 62 69 86 96 Outlet-02 SAD 6 1.00 HD 90 79 88 90 100 Outlet-03 SAD 6 1.00 HD 70 67 96 70 100 Totals: 250 208 83 246 98 SYSTEM/UNIT: RTU-OINAV-13 Tested By: Travis Wiskur AREA: CEILING Date: 12/14/2016 ill Unit Data Term Box Test Data VAV Address 1-13 Design Max Airflow 535 CFM Box Inlet Size 10 Actual Max Airflow 531 CFM K Factor 0.98 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-13 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type 0 Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD • 6 1.00 HD 75 77 103 72 96 Outlet-02 SAD 6 1.00 HD 75 59 79 70 93 Outlet-03 SAD 6 1.00 HD 75 66 88 82 109 Outlet-04 SAD 6 1.00 HD 95 111 117 96 101 Outlet-05 SAD 6 1.00 HD 75 76 101 77 103 Outlet-06 SAD 8 1.00 HD 140 185 132 134 96 Totals: - - - 535 574 107 531 99 • Flow Dynamic Balancing,LLC Page 13 of 35 FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-OINAV-14 Tested By: Travis Wiskur AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 1-14 Design Max Airflow 840 CFM Box Inlet Size 10 Actual Max Airflow 858 CFM K Factor 1.00 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-01NAV-14 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 8 1.00 HD 130 k 140 108 136 105 Outlet-02 SAD 8 1.00 HD 130 180 138 134 103 Outlet-03 SAD 6 1.00 HD 70 61 87 77 110 Outlet-04 SAD 6 1.00 HD k 70 60 86 77 110 Outlet-05 SAD 8 1.00 HD 130 167 128 137 105 Outlet-06 SAD 8 1.00 HD 130 149 115 128 98 Outlet-07 SAD 8 1.00 HD 130 32 ' 2• 5 123 95 Outlet-08 LN 6 1.00 HD 50 85 170 46 92 Totals: 840 874 104 858 102 r SYSTEM/UNIT: RTU-01/VAV-15 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 1-15 Design Max Airflow 360 CFM Box Inlet Size 6 Actual Max Airflow 355 CFM K Factor 0.84 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-15 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %e Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD 90 68 76 96 107 Outlet-02 SAD 6 1.00 HD 90 59 66 84 93 Outlet-03 SAD 6 1.00 HD 65 62 1 9• 5 60 92 Outlet-04 SAD 6 1.00 HD 65 60 92 69 106 Outlet-05 SAD 6 1.00 HD 50 54 108 46 92 Totals: 360 303 ' 8• 4 355 99 Ill Flow Dynamic Balancing,LLC Page 14 of 35 t: FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-01/VAV-16 Tested By: Rick Yzermans AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 1-16 Design Max Airflow 480 CFM Box Inlet Size 8 Actual Max Airflow 472 CFM K Factor 0.99 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-OINAV-16 Supply Outlet Summary System/Unit Outlet Size LxW I AK Instrument Design Prelim % Final %Final Type D '' Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 8 1.00 HD 240 215 90 233 97 Outlet-02 SAD 8 1.00 HD 240 245 102 239 100 Totals: 480 480 98 472 98 SYSTEM/UNIT: RTU-02 Tested By: Rick Yzermans AREA: ROOF Date: 12/14/2016 Unit Data Motor Data • Unit Manufacturer AAON J TU-02/5uDDly F$p Unit Model Number RN-070-3-0-EA09-3D9 Motor Manufacturer BALDOR Unit Serial Number 201608-BNGY55931 Motor Frame 256T J2TU-02/Filter Bank Motor HP 20 HP Filter Manufacturer AIRGUARD Motor RPM 1760 RPM Filter Type PLEATED Motor Rated Volts 460 Volts Filter Qty-S1 24 Motor Phase 3 Filter Size-S1 12X24X4 Motor Hertz 60 Hz Motor FL Amps 23.5 Amps Test Data Motor Service Factor 1.15 Design Airflow 22000 CFM Brake Horsepower 17.40 BHP Actual Airflow 24198 CFM Corrected FL Amps 26.91 Amps Design Outside Airflow 6050 CFM Nominal Efficiency 0.93 Actual Outside Airflow 5929 CFM Motor Power Factor 0.86% Design Return Airflow 15950 CFM Actual Return Airflow 18269 CFM Sheave Data RTU-02/SuDDIv Fart RTU-02/Suooly Fan Design RPM 1395 RPM Motor Sheave Model DIRECT DRIVE Motor Volts T1-T2 402 Volts _ Motor Volts T2-T3 401 Volts Test Pressures Motor Volts T1-T3 402 Volts Fan SP In -0.18 in.wc Motor Amps T1 23.00 Amps Fan SP Out 0.85 in.wc Motor Amps T2 24.00 Amps 0/A Damper Position 28% Motor Amps T3 23.00 Amps R/A Damper Position 72 cYo Air Test Data Design Hertz 60.0 HZ Actual Hertz 50.0 HZ Static Pressure St.Pt. 1.30 in.wc IIILog: RTU-02 12/12/2016 Travis Wiskur OA 32X96 AREA 21.3 5929 CFM Flow Dynamic Balancing,LLC Page 15 of 35 t. FLOW DYNAMIC BALANCING ID Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-01 Tested By: Travis Wiskur AREA: CEILING Date: 12/10/2016 Unit Data Term Box Test Data VAV Address 2-1 Design Max Airflow 400 CFM Box Inlet Size 8 Actual Max Airflow 377 CFM K Factor 0.89 Min Design CFM 120 CFM Actual Min Airflow 114 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 710 CFM Total Heating Cfm Design 435 CFM Total Heating Cfm Actual 824 CFM Log: RTU-02/FP VAV-01 12/10/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-01 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 200 169 85 182 91 Outlet-02 LN 8 1.00 HD 200 184 92 195 98 • Totals: 400 353 88 377 94 SYSTEM/UNIT: RTU-02/FP VAV-02 Tested By: Travis Wiskur AREA: CEILING Date: 12/10/2016 Unit Data Term Box Test Data VAV Address 2-2 Design Max Airflow 1540 CFM Box Inlet Size 12 Actual Max Airflow 1555 CFM K Factor 1.15 Min Design CFM 460 CFM Actual Min Airflow 473 CFM Design Fan Airflow 770 CFM Actual Fan Airflow 1260 CFM Total Heating Cfm Design 1230 CFM Total Heating Cfm Actual 1733 CFM RTU-02/FP VAV-02 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 160 60 38 161 101 Outlet-02 LN 8 1.00 HD 160 171 107 166 104 Outlet-03 LN 8 1.00 HD 160 163 102 158 99 Outlet-04 LN 8 1.00 HD 160 190 119 161 101 Outlet-05 LN 8 1.00 HD 160 186 116 165 103 Outlet-06 LN 8 1.00 HD 175 229 131 178 102 Outlet-07 LN 8 1.00 HD 180 237 132 180 100 Outlet-08 LN 8 1.00 HD 155 248 160 160 103 Outlet-09 LN 8 1.00 HO 230 275 120 226 98 40Totals: 1540 1759 114 1555" 101 Flow Dynamic Balancing,LLC Page 16 of 35 t: FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-03 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-3 Design Max Airflow 1310 CFM Box Inlet Size 12 Actual Max Airflow 1320 CFM K Factor 1.10 Min Design CFM 390 CFM Actual Min Airflow 376 CFM Design Fan Airflow 655 CFM Actual Fan Airflow 1085 CFM Total Heating Cfm Design 1045 CFM Total Heating Cfm Actual 1461 CFM Log: RTU-02/FP VAV-03 12/12/2016 Travis Wiskur FAN SET TO 100%NO FILTER RTU-02/FP VAV-03 Supply Outlet Summary System/Unit Outlet Size LxW 1 AK instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 180 185 103 183 102 Outlet-02 LN 8 1.00 HD 180 239 133 172 96 ill Outlet-03 LN 8 1.00 HD 180 187 104 188 104 Outlet-04 LN 8 1.00 HD 180 192 107 178 99 Outlet-05 LN 8 1.00 HD 180 281 156 180 100 Outlet-06 LN 8 1.00 HD 180 213 118 187 104 Outlet-07 LN 8 1.00 HD 230 229 100 232 101 Totals 1310 1526 116 1320 101 i Flow Dynamic Balancing,LLC Page 17 of 35 t.......: FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rands Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-04 Tested By: Travis Wiskur AREA: CEILING Date: 12/10/2016 Unit Data Term Box Test Data VAV Address 2-4 Design Max Airflow 575 CFM Box Inlet Size 8 Actual Max Airflow 576 CFM K Factor 1.00 Min Design CFM 170 CFM Actual Min Airflow 175 CFM Design Fan Airflow 335 CFM Actual Fan Airflow 560 CFM Total Heating Cfm Design 505 CFM Total Heating Cfm Actual 840 CFM Log: RTU-02/FP VAV-04 12/10/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-04 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff, Diff. Outlet-01 LN 8 1.00 HD 135 _ 159 118 138 102 Outlet-02 LN 8 1.00 HD 75 142 A 189 72 96 • Outlet-03 LN 8 1.00 HD 155 161 104 155 100 Outlet-04 LN 8 1.00 HD 215 120 56 211 98 Totals: 580 582 100 576 99 SYSTEM/UNIT: RTU-02/FP VAV-05 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-5 Design Max Airflow 615 CFM Box Inlet Size 8 Actual Max Airflow 578 CFM K Factor 0.61 Min Design CFM 180 CFM Actual Min Airflow 184 CFM Design Fan Airflow 615 CFM Actual Fan Airflow 886 CFM Total Heating Cfm Design 184 CFM Total Heating Cfm Actual 1070 CFM Log: RTU-02/FP VAV-05 12/12/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-05 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type 0 Factor Airflow Airflow Prelim Airflow Diff. Diff.. Outlet-01 LN 8 1.00 HD 170 118 69 168 99 Outlet-02 LN 10 1.00 HD 250 136 54 221 88 Outlet-03 LN 8 1.00 HD 195 128 66 189 97 Totals: 615 382 62 578 94 III Flow Dynamic Balancing,LLC Page 18 of 35 (ti FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-06 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-6 Design Max Airflow 780 CFM Box Inlet Size 10 Actual Max Airflow 790 CFM K Factor 0.97 Min Design CFM 230 CFM Actual Min Airflow 226 CFM Design Fan Airflow 400 CFM Actual Fan Airflow 480 CFM Total Heating Cfm Design 630 CFM Total Heating Cfm Actual 706 CFM RTU-02/FP VAV-06 Supply Outlet Summary System/Unit Outlet Size LxW t AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff, Diffff, Outlet-01 LN 10 1.00 HD 260 250 96 250 96 Outlet-02 LN 10 1.00 HO 260 265 102 265 102 Outlet-03 LN 10 1.00 HD 260 275 106 275 106 Totals: 780 790 101 790 101 • SYSTEM/UNIT: RTU-02/FP VAV-07 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-7 Design Max Airflow 400 CFM Box Inlet Size 8 Actual Max Airflow 418 CFM K Factor 0.81 Min Design CFM 120 CFM Actual Min Airflow 124 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 760 CFM Total Heating Cfm Design 435 CFM Total Heating Cfm Actual 884 CFM Log: RTU-02/FP VAV-07 12/12/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-07 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 200 170 85 218 109 Outlet-02 LN 8 1.00 HD 200 155 78 200 100 Totals: - 400 325 81 418 105 i Flow Dynamic Balancing,LL.0 Page 19 of 35 FLOW DYNAMIC BALANCING 0 Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-08 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 2-8 Design Max Airflow 2430 CFM Box Inlet Size 16 Actual Max Airflow 2459 CFM K Factor 1.07 Min Design CFM 730 CFM Actual Min Airflow 691 CFM Design Fan Airflow 1215 CFM Actual Fan Airflow 1800 CFM Total Heating Cfm Design 1945 CFM Total Heating Cfm Actual 2491 CFM Log: RTU-02/FP VAV-08 12/12/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-08 Supply Outlet Summary System/Unit Outlet Size LxW 1 AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 200 ' 175 88 210 105 Outlet-02 LN 8 1.00 HD 200 . 170 85 203 102 0 Outlet-03 LN 8 1.00 HD 200 170 85 186 93 Outlet-04 LN 8 1.00 HD 200 145 73 181 91 Outlet-05 LN 8 1.00 HD - 200 225 113 209 105 Outlet-06 LN 8 1.00 HD ' 200 230 . 115 194 97 Outlet-07 SAD 8 1.00 HD 175 250 143 182 104 Outlet-08 SAD 8 1.00 HD 175 285 163 189 108 Outlet-09 SAD 8 1.00 HD 175 220 126 166 95 Outlet-10 SAD 8 1.00 HD 175 190 109 191 109 Outlet-11 SAD 8 1.00 HD 175 195 111 188 107 Outlet-12 SAD 8 1.00 HD 180 180 100 181 101 Outlet-13 SAD 8 1.00 HD 175 215 123 179 102 Totals: 2430 2650 ' 109 2459 101 III __,....................._._.......... _ Flow Dynamic Balancing,LLC Page 20 of 35 ti FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-09 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 2-9 Design Max Airflow 1510 CFM Box Inlet Size 12 Actual Max Airflow 1552 CFM K Factor 1.36 Min Design CFM 450 CFM Actual Min Airflow 442 CFM Design Fan Airflow 755 CFM Actual Fan Airflow 1440 CFM Total Heating Cfm Design 1205 CFM Total Heating Cfm Actual 1882 CFM RTU-02/FP VAV-09 Supply Outlet Summary System/Unit Outlet Size L,xW/ AK Instrument Design Prelim % Final %Final. Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 205 210 102 219 107 Outlet-02 LN 8 1.00 HD 205 245 120 208 101 Outlet-03 LN 8 1.00 HD 205 210 102 207 101 Outlet-04 LN 8 1.00 HD 205 240 117 191 93 Outlet-05 LN 8 1.00 HD 140 180 129 145 104 S Outlet-06 LN 8 1.00 HD 140 205 205 146 153 109 Outlet-07 LN 8 1.00 HD 260 127 211 103 Outlet-08 LN 8 1.00 HD 205 270 132 218 106 Totals: 1510 1820 121 1552 103 SYSTEM/UNIT: RTU-02/FP VAV-10 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-10 Design Max Airflow 405 CFM Box Inlet Size 8 Actual Max Airflow 406 CFM K Factor 1.17 Min Design CFM 120 CFM Actual Min Airflow 117 CFM Design Fan Airflow 315 CFM Actual Fan Airflow 690 CFM Total Heating Cfm Design 315 CFM Total Heating Cfm Actual 807 CFM Log: RTU-02/FP VAV-10 12/12/2016 Travis Wiskur FAN ON LOW SPEED.SET AT 1%. RTU-02/FP VAV-10 Supply Outlet Summary System/Unit Outlet Size LacW/ AK instrument Design Prelim % Final %Final Type Co Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD 145 165 114 160 110 Outlet-02 LN 8 1.00 HD 145 185 128 142 98 Outlet-03 LN 8 1.00 HD 115 125 109 104 90 • Totals: 405 475 117 406 100 Flow Dynamic Balancing,LLC Page 21 of 35 (..t.......1- SLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/FP VAV-11 Tested By: Travis Wiskur AREA: CEILING Date: 12/12/2016 Unit Data Term Box Test Data VAV Address 2-11 Design Max Airflow 675 CFM Box Inlet Size 10 Actual Max Airflow 664 CFM K Factor 1.16 Min Design CFM 200 CFM Actual Min Airflow 196 CFM Design Fan Airflow 450 CFM Actual Fan Airflow 856 CFM Total Heating Cfm Design 650 CFM Total Heating Cfm Actual 1052 CFM Log: RTU-02/FP VAV-11 12/12/2016 Travis Wiskur FAN ON LOW SPEED,SET AT 1%. RTU-02/FP VAV-11 Supply Outlet Summary System/Unit Outlet Size LXW/ AK Instrument Design Prelim % Final %Final" Type 0 Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 LN 8 1.00 HD _ 115 125 109 111 97 Outlet-02 LN 6 1.00 HD 110 90 82 101 92 • Outlet-03 LN 8 1.00 HD 115 180 157 123 107 Outlet-04 LN 8 1.00 HD 115 175 152 121 105 Outlet-05 LN 6 1.00 HD 110 100 91 103 94 Outlet-06 LN 6 1.00 HD 110 110 100 105 95 Totals: 675 ' 780 116 664 98 SYSTEM/UNIT: RTU-02NAV-01 Tested By: Rick Yzermans AREA: CEILING Date: 12/9/2016 Unit Data Term Sox Test Data VAV Address 2-1 Design Max Airflow 1010 CFM Box Inlet Size 10 Actual Max Airflow 999 CFM K Factor 0.98 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02/VAV-01 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD 90 120 133 92 102 Outlet-02 SAD 6 1.00 HD 90 104 116 84 93 Outlet-03 SAD 6 1.00 HD 90 95 106 96 107 Outlet-04 SAD 6 1.00 HD 100 75 75 102 102 Outlet-05 SAD 6 1.00 HD 100 52 52 98 98 Outlet-06 SAD 6 1.00 HD 90 65 72 86 96 Outlet-07 SAD 6 1.00 HD 90 55 61 89 99 Outlet-08 SAD 6 1.00 HD 90 115 128 92 102 Outlet-09 SAD ' 6 1.00 HD 90 70 78 90 100 • Outlet-10 SAD 6 1.00 HD 90 105 117 86 96 Outlet-11 SAD 6 1.00 HD 90 100 111 84 93 Totals: 1010 956 ' 95 999 99 Flow Dynamic Balancing,LLC Page 22 of 35 ti FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/VAV-02 Tested By: Rick Yzermans AREA: CEILING Date: 12/9/2016 Unit Data Term Box Test Data VAV Address 2-2 Design Max Airflow 1660 CFM Box Inlet Size 14 Actual Max Airflow 1615 CFM K Factor 1.02 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02NAV-02 Supply Outlet Summary System/Unit Outlet Size LxW/ AK Instrument Design Prelim % Finai %Final Type D Factor Airflow Airflow Prelim Airflow diff. Diff. Outlet-01 SAD 6 1.00 - HD 75 90 120 68 91 Outlet-02 SAD 6 1.00 ' HD 75 150 200 70 93 Outlet-03 SAD 6 1.00 HD 75 ' 155 207 74 99 Outlet-04 SAD 6 1.00 HD 75 95 127 78 104 Outlet-05 SAD 8 1.00 HD 75 85 113 72 96 Outlet-06 SAD 8 1.00 HD 115 150 130 118 103 Outlet-07 SAD 8 1.00 HD ' 140 185 ' 132 141 101 Outlet-08 SAD 8 1.00 HD 160 170 106 161 101 Outlet-09 SAD 8 1.00 HD 120 135 113 117 98 4110 Outlet-10 SAD 8 1.00 HD - 120 100 83 116 97 Outlet-11 SAD 8 1.00 HD 170 95 56 162 95 Outlet-12 SAD 8 1.00 HD 160 120 75 148 93 Outlet-13 SAD 6 1.00 HD 75 70 93 73 97 Outlet-14 SAD 6 1.00 - HD 75 65 87 70 93 Outlet-15 SAD 6 1.00 HD 75 90 120 74 99 Outlet-16 SAD 6 1.00 HD 75 65 87 73 97 Totals: 1860 1820 110 1615 97 • Flow Dynamic Balancing,LLC Page 23 of 35 (ti.___ FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN,MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/VAV-03 Tested By: Rick Yzermans AREA: CEILING Date: 12/9/2016 Unit Data Term Box Test Data VAV Address 2-3 Design Max Airflow 1290 CFM Box Inlet Size 12 Actual Max Airflow 1264 CFM K Factor 0.97 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02NAV-03 Supply Outlet Summary System/Unit Outlet Size L,xW I AK instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD 100 90 90 105 105 Outlet-02 LN 6 1.00 HD 100 125 125 100 100 Outlet-03 SAD 6 1.00 HD 75 125 167 78 104 Outlet-04 SAD 6 1.00 HD 75 160 213 75 100 Outlet-05 SAD 8 1.00 HD 120 125 104 112 93 Outlet-06 SAD 8 1.00 HD _ 120 170 142 118 98 Outlet-07 SAD 6 1.00 HD 75 70 93 73 97 Outlet-08 SAD 6 1.00 HD _ 75 80 107 70 93 Outlet-09 SAD 6 1.00 HD 75 70 93 69 92 • Outlet-10 SAD 6 1.00 HD 75 75 100 73 97 Outlet-11 LN 6 1.00 HD 100 95 95 96 96 Outlet-12 SAD 6 1.00 HD 75 75 100 76 101 Outlet-13 SAD 6 1,00 HD 75 65 87 74 99 Outlet-14 SAD 6 1.00 HD 75 65 87 75 100 Outlet-15 SAD 6 1.00 HD 75 70 93 70 93 Totals: • 1290 ' 1460 113 1264 98 • Flow Dynamic Balancing,LLC Page 24 of 35 ti FLOW DYNAMIC BALANCING • Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02NAV-04 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 2-4 Design Max Airflow 1105 CFM Box Inlet Size 12 Actual Max Airflow 1083 CFM K Factor 1.20 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02/VAV-04 Supply Outlet Summary System/Unit Outlet Size LxW I AK Instrument Design Prelim % Final %Final Type 0 Factor :' Airflow Airflow Prelim Airflow. Diff. Diff. Outlet-01 SAD 8 1.00 HD 115 165 143 109 95 Outlet-02 SAD 8 1.00 HD 115 170 148 116 101 Outlet-03 SAD 6 1.00 HD 7• 5 85 113 76 101 Outlet-04 SAD 6 1.00 HD 75 90 120 72 96 Outlet-05 SAD 6 1.00 HD 7• 5 95 ' 127 72 96 Outlet-06 SAD 6 1.00 HD 75 80 107 78 104. Outlet-07 SAD 6 1.00 HD 100 101 101 102 102 Outlet-08 SAD 6 1.00 HD 75 80 107 77 103 Outlet-09 SAD 8 1.00 HD 75 90 120 71 95 • Outlet-10 SAD 8 1.00 HD 75 85 113 75 100 Outlet-11 LN 8 1.00 HD 135 135 100 125 93 Outlet-12 SAD 8 1.00 HD 115 115 100 110 96 Totals: 1105 1291 117 1083 98 SYSTEM/UNIT: RTU-02/VAV-05 Tested By: Rick Yzermans AREA: CEILING Date: 12/14/2016 Unit Data Term Box Test Data VAV Address 2-5 Design Max Airflow 960 CFM Box Inlet Size 10 Actual Max Airflow 970 CFM K Factor 1.10 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02NAV-05 Supply Outlet Summary System/Unit Outlet Size"LxW/ AK Instrument Design Prelim % Final %Final Type 0 Factor Airflow Airflow Prelim Airflow Diff:' Diff. Outlet-01 SAD 8 1.00 HD 115 160 139 117 102 Outlet-02 SAD 8 1.00 HD 115 145 126 112 97 Outlet-03 SAD 6 1.00 HD 75 100 133 78 104 Outlet-04 SAD 6 1.00 HD 75 ' 110 147 74 99 Outlet-05 SAD 6 1.00 HD 100 80 80 106 106 Outlet-06 SAD 6 1.00 HD 75 95 127 79 105 Outlet-07 SAD 6 1.00 HD 75 90 120 77 103 Outlet-08 SAD 6 1.00 HD 75 70 93 78 104 Outlet-09 SAD 6 1.00 HD 75 55 73 73 97 Outlet-10 SAD 6 1.00 HD 75 65 87 76 101 • Outlet-11 LN 6 1.00 HD 105 75 71 100 95 Totals: 960 1045 109 970 101 Flow Dynamic Balancing,LLC Page 25 of 35 ti- FLOW DBALANCING S Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-02/VAV-06 Tested By: Rick Yzermans AREA: CEILING Date: 12/8/2016 Unit Data Term Box Test Data VAV Address 2-6 Design Max Airflow 670 CFM Box Inlet Size 10 Actual Max Airflow 694 CFM K Factor 1.14 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02NAV-06 Supply Outlet Summary System/Unit Outlet Size;LxW I AK instrument Design Prelim % Final %Final= Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 8 1.00 HD 145 _ 210 145 152 105 Outlet-02 SAD 6 1.00 HD 75 130 173 78 104 Outlet-03 SAD 6 1.00 HD 75 115 153 76 101 Outlet-04 SAD A 6 1.00 HD 100 65 65 100 100 Outlet-05 SAD 6 1.00 A HD 75 90 120 74 99 Outlet-06 SAD 6 1.00 HD 100 45 45 109 109 Outlet-07 LN 6 1.00 HD 100 ' 90 90 105 105 Totals: - - - - 670 745 111 694 104 • SYSTEM/UNIT: RTU-02NAV-07 Tested By: Rick Yzermans AREA: CEILING Date: 12/9/2016 Unit Data Term Box Test Data VAV Address 2-7 Design Max Airflow 450 CFM Box Inlet Size 8 Actual Max Airflow 460 CFM K Factor 1.05 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-02NAV-07 Supply Outlet Summary System/Unit Outlet Size'LxW/ AK - Instrument Design Prelim % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD 100 85 85 108 108 Outlet-02 SAD 6 1.00 A HD 75 80 107 76 101 Outlet-03 SAD 4 6 1.00 ND 75 105 A 140 78 104 Outlet-04 LN 6 1.00 HD 100 125 1247----75r---r-00 Outlet-05 LN 6 1.00 HD 100 70 70 98 98 Totals: 450 465 103 ', 460 102 0 Flow Dynamic Balancing,LLC Page 26 of 35 tl FLOW DYNAMIC BALANCING i Roof Top Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: RTU-O2NAV-08 Tested By: Rick Yzermans AREA: CEILING Date: 12/9/2016 Unit Data Term Sox Test Data VAV Address 2-8 Design Max Airflow 280 CFM Box Inlet Size 6 Actual Max Airflow 281 CFM K Factor 0.65 Min Design CFM 0 CFM Actual Min Airflow 0 CFM RTU-O2NAV-08 Supply Outlet Summary System/unit Outlet Size LxW I AK instrument Design Prelim ! % Final %Final Type D Factor Airflow Airflow Prelim Airflow Diff. Diff. Outlet-01 SAD 6 1.00 HD k 100 50 50 102 102 Outlet-02 SAD 8 1.00 • HD 120 60 50 117 98 Outlet-03 SAD 6 1.00 HD 60 30 50 62 103 Totals: 280 140 50 281 100 III III Flow Dynamic Balancing,LLC Page 27 of 35 ti FLOW DYNAMIC BALANCING • Fan Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: EF-01 Tested By: James Wages AREA: 1099 Date: 12/14/2016 Unit Data Motor Data Fan Manufacturer COOK Rated Airflow Capacity 3700 CFM Fan Model Number 195C8B Motor Manufacturer WEG Fan Serial Number 14689266 Motor HP 1 1/2 HP Motor RPM 1725 RPM Test Data Motor Rated Volts 460 Volts Design Airflow 3050 CFM Motor Phase 3 Actual Airflow 3038 CFM Motor Hertz 60 Hz Design RPM 1011 RPM Motor FL Amps 3.00 Amps Actual RPM 864 RPM Motor Service Factor 1.15 Motor Volts T1-T2 472 Volts Brake Horse Power 1.53 BHP Motor Volts T2-T3 472 Volts Corrected FL Amps 2.93 Amps Motor Volts T1-T3 471 Volts Nominal Efficiency 0.84% Motor Amps T1 2.30 Amps Power Factor 0.72% Motor Amps T2 2.30 Amps Motor Amps T3 2.32 Amps Sheave Data Motor Sheave Model 1 VP34 Motor Sheave Diam. 3 1/4 in. Motor Sheave Bore 5/8 in. Ill Fan Sheave Model AK64 Fan Sheave Diam. 6 1/4 in. Fan Sheave Bore 5/8 in. Number of Belts 1 Belt Size AP27 Sheave Center Line 7 in. Log: EF-01 12/14/2016 James Wages FAN RATED FOR 3700 CFM,OUTLET DESIGN TOTAL IS 3050 CFM. III Flow Dynamic Balancing,LLC Page 28 of 35 (CI FLOW DYNAMIC BALANCING • Fan Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 EF-01 Exhaust Inlet Summary System/Unit Inlet Type Size LxW/ AK Instrument Design Prelim % Final %Final D Factor' Airflow Airflow Prelim Airflow Diff, Diff: Inlet-01 EAG 8/8 1.00 HD 100 . 110 110 105 105 Inlet-02 EAG 8/8 0.44 RVA 100 55 55 93 93 Inlet-03 EAG 8/8 1.00 ND 50 64 128 55 110 Inlet-04 EAG 8/8 1.00 HD 100 91 91 101 101 Inlet-05 EAG 8/8 1.00 HD 100 ' 104 104 104 104 Inlet-06 EAG 8/8 1.00 HD 50 65 130 55 110 Inlet-07 EAG 8/8 1.00 HD 50 80 160 53 106 Inlet-08 EAG 8/8 0.44 RVA 100 0 0 91 91 Inlet-09 EAG 8/8 0.44 . RVA . 100 0 0 92 92 Inlet-10 EAG 10/10 1.00 HD 200 186 93 208 104 Inlet-11 EAG 8/8 1.00 HD _ 100 277 277 90 90 Inlet-12 EAG 8/8 1.00 HD 5• 0 99 198 45 90 Inlet-13 EAG 8/8 1.00 HO 50 12 24 53 106 Inlet-14 EAG 8/8 1.00 HD 50 155 310 50 100 Inlet-15 EAG 8/8 1.00 HD - 50 144 288 45 90 Inlet-16 EAG 8/8 1.00 HD 50 92 184 46 92 Inlet-17 EAG 8/8 1.00 HD 100 109 109 108 108 Inlet-18 EAG 8/8 1.00 HD 100 130 130 105 105 Inlet-19 EAG 10/10 1.00 - HD 245 226 92 255 104 Inlet-20 EAG 10/10 1.00 HD 200 239 120 208 104 • Inlet-21 EAG 8/8 1.00 HD 75 57 76 69 92 Inlet-22 EAG 8/8 1.00 HD k 5• 0 112 224 54 108 Inlet-23 EAG 8/8 1.00 ND 50 44 88 47 94 Inlet-24 EAG 8/8 1.00 HD 50 53 106 52 104 Inlet-25 EAG 8/8 1.00 HD 50 57 114 51 102 Inlet-26 EAG 8/8 1.00 HD 100 68 68 99 99 Inlet-27 EAG 10/10 1.00 HD 200 38 19 193 97 Inlet-28 EAG 10/10 1.00 . HD 200 243 122 186 93 Inlet-29 EAG 8/8 1.00 HD 50 147 294 48 96 Inlet-30 EAG 8/8 1.00 HD 50 64 128 48 96 Inlet-31 EAG 10/10 1.00 HD . 180 75 42 183 102 Inlet-32 EAG 8/8 1.00 ' HD - 5• 0 163 326 46 92 Totals: 3050 3359 110 3038 100 III Flow Dynamic Balancing,LLC Page 29 of 35 ,,,d, (:....%;:___, FLOW DYNAMIC BALANCING Fan Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: EF-02 Tested By: James Wages AREA: 1102 Date: 12/14/2016 Unit Data Motor Data Fan Manufacturer COOK Rated Airflow Capacity 450 CFM Fan Model Number 165RX17DEC Motor Manufacturer US MOTOR Fan Serial Number 297SG52859-00/0001801 Motor Frame 48Y Motor HP 1/2 HP Test Data Motor RPM 1725 RPM Design Airflow 370 CFM Motor Rated Volts 115 Volts Actual Airflow 384 CFM Motor Phase 1 Design RPM 1128 RPM Motor Hertz 60 Hz Actual RPM 811 RPM Motor FL Amps 6.20 Amps Motor Volts T1-T2 120 Volts Motor Service Factor 1.15 Motor Amps T1 2.80 Amps Brake Horse Power 0.25 BHP Corrected FL Amps 5.94 Amps Nominal Efficiency 0.80% Power Factor 0.70% Sheave Data Motor Sheave Model DIRECT DRIVE Log: EF-02 12/14/2016 James Wages FAN RATED FOR 450 CFM.OUTLET DESIGN TOTAL IS 370 CFM. EF-02 Exhaust Inlet Summary System/Unit Inlet Type Size LxW t AK - Instrument Design Prelim % Final %Final D Factor Airflow Airflow Prelim Airflow. Diff. Diff. Inlet-01 EAG 10/10 1.00 HD 200 470 235 202 101 Inlet-02 EAG 10/10 1.00 HD 170 520 306 182 107 Totals: 370 ' 990 288 384 104 Flow Dynamic Balancing,LLC Page 30 of 35 Flow Dynamic Balancing,LLC Page 31 of 35 FLOW DYNAMIC BALANCING • Fan Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Ronde Jackson PROJECT#: 1216 SYSTEM/UNIT: TF-01 Tested By: James Wages AREA: EQUIPMENT ROOM Date: 12/14/2016 Unit Data Motor Data Fan Manufacturer COOK Rated Airflow Capacity 500 CFM Fan Model Number GN-720 Motor Manufacturer COOK Motor HP FRAC HP Test Data Motor Rated Volts 115 Volts Design Airflow 500 CFM Motor Phase 1 Actual Airflow 489 CFM Motor Hertz 60 Hz Actual RPM DD RPM Motor FL Amps 3.90 Amps Motor Volts T1-T2 119 Volts Motor Service Factor TP Motor Amps Ti 2.10 Amps Brake Horse Power 0.19 BHP Corrected FL Amps 3.77 Amps Nominal Efficiency 0.80°A. Power Factor 0.70°A) Sheave Data Motor Sheave Model DIRECT DRIVE TF-01 Exhaust Inlet Summary System/Unit Area Served Inlet Type Size LxW/ AK Instrument Design Prelim % Final %Final • D Factor Airflow Airflow Prelim Airflow Duff. Diff. Inlet-01 EAST EAG 16X10 1.11 RVA 500 578 116 542 108 ELEVATOR Totals: - - 500 578 116 542 108 1110 Flow Dynamic Balancing,LLC Page 31 of 35 FLOW DYNAMIC BALANCING • Fan Unit PROJECT: CPC FAIRVIEW DATE: 12/14/2016 LOCATION: EAGAN, MN CONTACT: Rande Jackson PROJECT#: 1216 SYSTEM/UNIT: TF-02 Tested By: James Wages AREA: EQUIPMENT ROOM Date: 12/14/2016 Unit Data Motor Data Fan Manufacturer COOK Rated Airflow Capacity 500 CFM Fan Model Number GN-720 Motor Manufacturer COOK Motor HP FRAC HP Test Data Motor Rated Volts 115 Volts Design Airflow 500 CFM Motor Phase 1 Actual Airflow 529 CFM Motor Hertz 60 Hz Actual RPM DID RPM Motor FL Amps 3.90 Amps Motor Volts T1-T2 120 Volts Motor Service Factor TP Motor Amps Ti 2.20 Amps Brake Horse Power 0.20 BHP Corrected FL Amps 3.74 Amps Nominal Efficiency 0.80% Power Factor 0.70°A) Sheave Data Motor Sheave Model DIRECT DRIVE TF-02 Exhaust Inlet Summary System/Unit Area Served Inlet Type Size LxW I AK Instrument Design Prelim % Final %Final • D Factor Airflow Airflow Prelim Airflow Diff. Inlet-01 WEST EAG 16X10 1.11 RVA 500 575 115 529 106 ELEVATOR Totals: - - - 500 575 115 529 106 4111 Flow Dynamic Balancing,LLC Page 32 of 35 whin.I BRAT ION DATA SHEET FLOW DYNAM C BALANCING -i•Ct--„Q1 4 • • ;• ,0';;„, ;'s ; ; ;•;;;;_ -0i ; • 4211' FLOW DYNAMIC BALANCING RAMP AMPERE GPM GALLONS PER MINUTE ADJ ADJUSTABLE HD HEAD ADM AIRDATA MULTIMETER HD HOOD AF AIRFOIL HP HEAT PUMP AFMS AIR FLOW MEASURING STATION HWR HOT WATER RETURN AHU AIR HANDLING UNIT HWS HOTWATER SUPPLY AUTO AUTOMATIC HX HEAT EXCHANGER BPH BRAKE HORSE POWER HZ HERTZ BTU BRITISH THERMAL UNIT IN INCH BTUH BTU PER HOUR KH KITCHEN HOOD CD CEILING DIFFUSER KHEF KITCHEN HOOD EXHAUST FAN CFM CUBIC FEET PER MINUTE KW KILOWATT CL CENTERLINE LAB LABORATORY CUH CABINET UNIT HEATER LAT LEAVING AIR TEMPERATURE CWR CHILLED WATER RETURN LB/LBS POUND/POUNDS CWS CHILLED WATER SUPPLY LWT LEAVING WATER TEMPERATURE DDC DIRECT DIGITAL CONTROLS MA MIXED AIR EA EXHAUST AIR MAU MAKE UP AIR UNIT 'AT ENTERING AIR TEMPERATURE MUA MAKE UP AIR UNIT EXHAUST FAN MAX MAXIMUM EFF EFFIENCY MECH MECHANICAL ESP EXTERNAL STATIC PRESSURE MEZZ MEZZANINE EWT ENTERING WATER TEMPERATURE MIN MINIMUM FA FRESH AIR MISC MISCELLANEOUS FCU FAN COIL UNIT N/A NOT APPLICABLE FPM FEET PER MINUTE NA NOT ABLE FT FOOT/FEET OA OUTSIDE AIR FTR FINNED TUBE RADIATION P PUMP GAL GALLON PD PITCH DIAMETER • ti FLOW DYNAMIC BALANCING ii PD PRESSURE DROP TC TEMPERTURE CONTROL PF POWER FACTOR TEMP TEMPERTURE PH PHASE TF TRANSFER FAN PRV POWER ROOF VENTILATOR TFSP TOTAL FAN STATIC PRESSURE PSI POUNDS PER SQ, INCH TS TEMPERTURE SENSOR RA RETURN AIR TSP TOTAL STATIC PRESSURE RAD RADIATION UH UNIT HEATER REG REGISTER UV UNIT VENTILATOR RF RETURN FAN V VOLT RH RELATIVE HUMIDITY VAV VARIABLE AIR VOLUME RH RELIEF HOOD VEL VELOCITY RHC REHEAT COIL VOL VOLUME RPM REVELUTIONS PER MINUTE WB WET BULB RTU ROOF TOP UNIT & AND SA SUPPLY AIR @ AT SAT SUPPLY AIR TEMPERATURE $ MONEY SF SUPPLY FAN # NUMBER SQ SQUARE % PERCENT iliSTAT THERMOSTAT - MINUS/NEGITIVE TRANSFER AIR TB TERMINAL BOX 0