Loading...
4872 Steeplechase Way ' 't., \ 14)'t? ` ;Ll(.)—ii C(,F r Use BLUE or BLACK Ink I 4‘0111 \f C DLIKl b For Office Use I City of Eaall oi(i ` o qw ! V Permit#: , . , i qo Ilk Li x 3830 Pilot Knob Road Permit Fee. ai Eagan MN 551221 r v I.Lip Date Received: to'Ir 17 Phone: (651)675-5675 ` l�01. Fax: (651)675-5694 j, vi \L[cS(j1 t Staff: Q 2016 RESIDENTIAL BUILDING PERMIT APPLICATION .dev° Date: 12-3-16 Site Address: 4872 Steeplechase Way Unit#: �� I Name: Norton Homes, LLC Phone: 763-559-2991 9 ent! 18215 45th Ave N Ste. D OwR r Address/City/Zip: " ,��6 v ,i Applicant is: X Owner X Contractor L 41 - 1 si,,,r.., v (;,-, ,r,,i,o,,,,r,,,--..,higt , Ty a OWork Description of work: New Home ; f4 M Construction Cost # i OOD Multi-Family Building: (Yes /No X ) _, Norton Homes, LLC Chris or Pat Company: Contact 18215 45th Ave N Ste. D Plymouth Address: City: Co .0101',,S1 MN 55446 763-559-2991 path@ or chrisn@nortonhomes.com 41, State: Zip: Phone: Email BC639221 License#: Lead Certificate# If the project is exempt from lead certification, please explain why: COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? Yes X No If yes,date and address of master plan: Licensed Plumber: 1 'l`t i(`<- S Stet 4-. i • .r_1i-N Phone:1 49'3' G'g-- 1 I LM Mechanical Contractor: Sedgwick Heating & AC Phone: 952-881-9000 Sewer&Water Contractor: DSM Excavating CO Inc Phone: 612-919-4340 Fire Suppression Contractor: NA Phone: NOTES�asnd u o gdocum�, aysbm � oid t epuhbfomaton Pono f th ��tmayb "ioi ed,snon_p�c � �� � eson t�# rm h*ckto t;,Uzm �' 444uVl.� 44* 4 . x. *i<IA4'si ,: ;�t s!i °' ti ,�. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. xChris Norton x 1 IL Applicant's Printed Name App Tcant's Signature Page 1 of 3 DO NOT WRITE BELOW THIS LINE HMO SUB TYPES In 17 ( - 1OI we` Foundation Fireplace Porch(3-Season) _ E erior Alteration(Single Family) Single Family Garage Porch(4-Season) _ E erior Alteration(Multi) Multi Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex Lower Level Pool Accessory Building WORK TYPES New Interior Improvement Siding Demolish Building* Addition Move Building Reroof Demolish Interior Alteration Fire Repair Windows Demolish Foundation Replace _ Repair Egress Window _ Water Damage Retaining Wall *Demolition of entire building-give PCA handout to applicant DESCRIPTION Valuation ay1137 Occupancy but.,f MCES System Plan Review Code Edition ,t,i'S'' SAC Units (25% 100%?(' ) Zoning 11 i City Water Census Code Stories gft. Booster Pump #of Units Square Feet 5 - "lif 0 PRV #of Buildings Length SY Fire Suppression Required Type of Construction ` l Width i''')) REQUIRED INSPECTIONS )C Footings (New Building) Meter Size: )( Footings (Deck) )( Final/C.O. Required Footings (Addition) Final/No C.O. Required Foundation x Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test Roof: Ice &Water _Final Pool: _Footings Air/Gas Tests _Final Framing 30 Minutes 1 Hour Drain Tile f Fireplace: X Rough In k Air Test x Final Siding: Stucco Lath X Stone Lat _Brick EFIS X Insulation Windows X Sheathing Retaining Wall:_Footings_Backfill_Final Sheetrock Ix Radon Control Fire Walls Fire Suppression: _Rough In_Final X Braced Walls /1t Erosion Control Shower Pan _ Other: Reviewed By: 1-1, , Building Inspector RESIDENTIAL FEES r)/9-(11, uiv!P-' 1 b y/ F o'% ' 31 ? J Base Fee "lig a Q Surcharge la ► X lL 12 )` 7 IL / 7 Plan Reviewj MCES SAC � ` '� �. ,.` � 2 c.l� �'j..�4:c;3$1‘;1' City SAC ,: (1 / , ' Utility Connection Charge f,,..;:(7:„; tit, ) S&W Permit&Surcharge 5 Pirrl / 3 0 't� t Treatment Plant " (1(4i J� 7� / y« Copies A L" 7 J w i 1 1 2-47 (2 TOTALi.. 2-2'4 / t,? I L-(1) tall New Construction Energy Code Compliance Certificate Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution Date Certificate Post panel. Place your Mailing Address of the Dwelling or Dwelling Unit City Ingo here 4872 Steeplechase Way Eagan, MN Name of Residential Contractor MN License Number Norton Homes THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply Passive(No Fan) r-'uiVe tvvnn sari dna monurneter 0 0, or other system monitoring N c (1) i'lo,iino\ F0 1-/›; Location(or future location)of Fan: Zo T N aC - O O) w 0) _ td 0 p, 15; 0 O -O N O7 eL a 0 n _O Q m m 0 a) T co Insulation Location °Z —° -° O w N m `o a) a E E 2 a a 0 N 0 .D .n. cucuN _ O) O) H c z I. Li. ti u_ 2 EE Other Please Describe Here Below Entire Slab s-16 P6----; // ,C Foundation Wall is-F� X ' i,erbitxx ,/G .1C/i . 'j1 Jq3 Perimeter of Slab on Grade Rim Joist(1st Floor) -2, ><' Rim Joist(2nd Floor+) 2-1,1 Wall r)- Ceiling,flat F1'1 X Ceiling,vaulted t -5 ' Bay Windows or cantilevered areas -`Zt x Floors over unconditioned area Z-14:- . A/Lt/-;10•./Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: Q Teit X .Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): r� 1 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Cooling System Heater X Not required per mech.code Fuel Type Natural Gas Electric Electric Passive Manufacturer Lennox Lennox Powered EL296UH070XV36B/ 13AXCN-036 Interlocked with exhaust device. Model ML193UHXP60C /13AXCN-060 Describe: Input in 66,000& Capacity in Output 3 and 4 Other,describe: Rating or Size BTUS: 110,000 Gallons: ,,` in Tons: AFUE or 96/93 SEER 14/13 Location of duct or system: Efficiency HSPF% /EER Heating Loss Heating Gain Cooling Load Residential Load Calculati<53,380/74,891 24,695/40,166 32,908/53,673 Cfm's "round duct OR MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech.code Select Type Passive X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 113 High: 235 Other,describe: Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: Balanced Ventilation capacity in cfms: HRVs in Mech Room(2(70 cfm)Eighf•O CFM bath fans(360)Two 80 CFM Bath Fan Location of fan(s),describe: Cfm's Capacity continuous ventilation rate in cfms: 140 "round duct OR Total ventilation(intermittent+continuous)rate in cfms: 780 "metal duct Builders Associaton of Minnesota version 101014 Ventilation, Makeup and Combustion Air Calculations Submittal Form For New Dwellings These blank submittal forms and instructions are available at the City of Chanhassen website and at City Hall. The completed form must be submit- ted in duplicate at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: http://www.d.chanitassen.mn.usiservibulld.h rm.,. Site address (.t r7 L_ (tea Date ,2_G_/ , r-�ily r^ltEt�` Contractor f/ �,,ttll Completed . J Section A - Ventilation Quantity i (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet(Conditioned area including �y • Basement–finished or unfinished) / Total required ventilation 2 7f — Number of bedrooms Continuous ventilation . / Directions-Determine the total and continuous t entilation rate by either using Table N1104.2 or equation 11-1. ' The table and equation are below. Table N1104.2 Total and Continuous Ventilation Rates(in cfm) • JI • Number of Bedrooms _ 1 2 • 3 4 ' 5 _6 Conditioned space(in Total/. Total/ Total/ Total/ Total/ Total/ sq.ft.) continuous continuous continuous continuous continuous continuous 1000-1500 .60/40 L75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 . 140/70 155/78 2501-3000 90/45 105/53 , 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83. 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83. 180/90 195/98 210/105 225/113 Equation 11-1 ' . • ' • (0.02 x square feet of conditioned space)+(15 x(number of bedrooms+1))=Total ventilation rate(cfm) i Conditioned space includes the basement. . 2 if conditioned space exceeds 6000 sq. ft._or.there,are„more than 6 bedrooms, us ' ' . Equation 11-1 from&CtiOri N1104.2 to calculate total ventilation rate. _ l' Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventila- tors (ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air Intake,or both,for defrost or other equipment cycling. Continuous ventilation•A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided,on a con- tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. Page 1 of 6 I Section B • Ventilation Method PLA o t'tI` (Choose either balanced or exhaust only) Balanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recov- p Exhaust only cry Ventilator)—cfm of unit In tow must not exceed continuous vend- Continuous fan rating In cfm tattoo rating by more than SAO%. Low din: —7a/..,0 High cfm: Cc-•( /R r. Continuous fan rating in cfm(capacity must not exceed ff continuous ventilation rating by mote than 100%) Directions-Choose the method of ventilation,balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV s. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C • Ventilation Fan Schedule Description Location Continuous Intermittent 1442 VjC 2__ edlo n ( 12490 H^ 7 1- 742 14° C7 f3U r—a .44, a nc( u,47 T2490,-,s 47` • • Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it is used for continuous or Intermittent ventilation. The fan that is chose forcontlnuous ventilation must be equal to or greater than the low cfm air rating and less than 100%greater than the continuous rate. (For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not exceed 80 cfm.)Automatic controls may allow.the use of a larger fan that is operated a percentage of each hour. !j Section D Ventilation Controls ! (Describe o�pe�r}ation and control of the continuous and intermittent ventilation) Z K 7r9 - 11/6 1 SeL� -t6 1-14 Pt C" 10 �H�i•�NOS(S �FM, �e:A F i ii 4 . tt , L4 4 / S,. Directions-Describe the operation of the ventilation system. There should be adequate detail for plan reviewers and Inspectors to verify design and Installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans are used for building ventilation,describe the operation and location of any controls,Indicators and legends. if an t:RV or HRV Is to be installed,describe how it will be installed.if it will be connected and interfaced with the air handling equipment,please describe such connections as detailed In the manufactures'installation Instructions.if the Installation Instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation,such interconnection shall be made and described. Section E f Make-up air `"'_ Passive(determined from calculations from Table 5013.1) Powered(determined from calculations from Table 501.3.1) interlocked with exhaust device(determined from calculation from Table 501.3.7.) Other,describe: ' Location of duct or system ventilation make-up air Determined from make-up air opening table cfm 1 Size and type(round,rectangular,flex or rigid) (NR means not required) • • Page 2 of 6 ). ew will Directionse •In order to determine the makeup air,Table 501.3.1 must be filled out(see below a installed,most une installations,e column will be appropriate,however,if atmospherlcailyvenled appliances or solid fuel appliances 501,3,2 and size the opening. Transfer the cfm,size of opening and type For existing dwellings,see!MC 501.3,3. Please note,if the makeup air quantity Is negative,no additional makeup air will be re- quired for ventilation,if the value Is positive refer to Tablemust be installed per IMC 501.3.2.3. (round,rectangular,flex or rigid)to the last line of section D. The make-up air supply Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS One atmospherically vent Multiple atmospherical- (Additional combustion air will be re•wired for combustion a•.Ifances,see KAIR method for calculations ly vented gas or oil One or multipleet powervent ap- one assistedor appliances ppi i e ncep- or oil appliance or ventor cedirentventvenpordire andvgas appliances plfances or no combus- power vent or direct vent one solid fuel appliance appliances or solid fuel tion appliances appliances Column C Column D Column Columna 1 0.06 0.030.15 0.09 a)pressure factor (cfm/sf) b)conditioned floor area(sf)(including .-•7 1 unfinished basements ! Estimated House Infiltration(cfm);[la I 4/0' � 7• -7 x1bJ C"-- 2.Exhaust Capacity a)continuous exhaust-only ventilation system(dm);(not applicable to ba- lanced ventilation systems such as 135 135 HRv) 135 135 b)clothes dryer(dm) c)80%of largest exhaust rating(cfm); � Kitchen hood typically r`-y 5o (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) d)80%of next largest exhaust rating (cfm); bath fan typically Not (not applicable if recirculating system Applicable or if powered makeup air is electrically interlocked and matched to exhaust) r Total Exhaust Capacity(dm); • { [2a+2b+2c+24 3.Makeup Air Quantity(dm) I �j a)total exhaust capacity(from above) b)estimated house infiltration(from l •(� -?5.-- j above) I II Makeup Air Quantity(dm); [3a-3b13 (if value is negative,no makeup air is needed) 0 4.For makeup Air Opening Sizing,refer �/ to Table 501.4.2 f A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance°mos hericallyvented appllancesappliances. mayalso be Invent and direct vent appliances may be used.) g. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than a A cluded.) C' are multiple atmospherically vented gas or oil appliances using a common vent or If there are atmospherically vented gas or oil Use this column if there Is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuelappliance. D. Use this column if there P appliances and solid fuel appliances, Page 3 of 6 Makeup Air Opening Table for New and Existing Dwelling Table 501.3.2 One or multiple power One or multiple fan- One atmospherically Multiple atmospherically Duct vent,direct vent ap- assisted appliances and - vented gas or oil ap- vented gas or oil ap• di- pliances,or no combus- power vent or direct pliance or one solid fuel pilances or solid fuel ameter tion appliances vent appliances appliance appliances Column A Column B Column C Column D 3 Passive opening 1-36 1-22 1-15 1-9 23-41 16-28 10-17 4 Passive opening 37-66 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47—69 29—42 6 Passive opening 164 70-99 43-61 7-232 101-143 62-83 8 Passive opening 233-317 144-195 100-135 9 Passive opening 318-419 196-258 136-179 84-110 w/motorized damper 111-142 10 Passive opening 420-539 259-332 180-230 w/motorized damper _ - 143-179 11 Passiveopening 540-679 333-419 231-290 w/motorized damper >179 NA Powered makeup air >679 >419 >290 Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90•degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used,increase the duct diameter by one inch.Flexible duct shall be stretched with minimal sags.Compressed duct shall not be accepted. C, Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance Is installed. D, Powered makeup air shall be electrically interlocked with the largest exhaust system. Sections F Combustion air Not required per mechanical code(No atmospheric or power vented appliances) Passive(see IFGC Appendix E,Worksheet E-1) 'Size and type I Other,describe: - Explanation-If no atmospheric or power vented appliances are installed,check the appropriate box,not required, if a power vented or atmospherically vented appliance installed,use IFGC Appendix E,Worksheet E-1(see below). Please enter size and type. Combus- tion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. • . Page 4 of 6 . Norton Construction 4872 Steeplechase Way Eagan, Dakota ---- CUSTOMER NAME INSTALLATION ADDRESS INSTALL CITY&COUNTY SALE DATE SALESREP NAME Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,Is called the Known Air Infiltration Rate Method. For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace,Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance Information. Draft/Fan Assist/Power Vent Input Direct Vent Input Furnace/Boller: Draft Hood El Fan Assisted Direct Vent Input: 0 Btu/hr 176000 Btu/hr or Power Vent Water Heater: 0Electric Water Heater Draft Hood U Fan Assisted ❑Direct Vent Input: 0 Btu/hr Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. '1,436 The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 LxWxH L W H Step 3:Determine Alr Changes per Hour(ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method). If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) MECH RM MECH RM DIM 1 DIM 2 4a.Standard Method Total Btu/hr input of all combustion appliances Input: 0 Btu/hr Li 14.5 L2 Use Standard Method column in Table E-1 to find Total Required TRV: 1 ft3 � Volume(TRV) Wl 11 W2I-J C If CASS V Volume(from Step 2)is greater than TRV then no outdoor openings are needed. If CAS Volume(from Step 2)is less than TRV then go to STEP 5. H 9 H2 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr Input of all fan-assisted and power vent appliances Input: Btu/hr 1435.5 0 Use Fan-Assisted Appliances column in Table E-1 to find RVFA: ft3 Required Volume Fan Assisted(RVFA) VOL1 VOL2 Total Btu/hr input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= + = TRV ft3 If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed. NO CAI NEEDED If CAS Volume(from Step 2)Is less than TRV then go to STEP 5. Step S:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) 1 436 / 1 1,435.5000 Step 4b) Ratio= = Step 6:Calculate Reduction Factor(RF). RF=1 minus Ratio Step 4b)RF=1- _ Step 7:Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area(CADA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA= /3000 Btu/hr per int= 0.00 in2 Step 8:Calculate Minimum CAOA, Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 0.00 x = 0.00 in2 step 4b) Step 9:Calculate Combustion Air Opening Diameter(CAOD) CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 0.00 in.diameter Step 4b) go up one Inch in size if using flex duct 1 if desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. 17.1 HIT CHECK BOX 4X TO COMPLETE CALCULATIONS Page 5 of 6 Load Short Form Job: Anand Residence,4872... 4 wrig ttsoft Date: December 1 ,2016 2nd Floor Zone By: Anthony Averse WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... Project Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Design Information Htg Clg Infiltration Outside db (°F) -15 88 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 85 13 Fireplaces 1 (Tight) Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/Ib) 32 29 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade ELITE 90 Trade MERIT Model EL296UH070XV36B-* Gond 13ACXN036-230-** AHRI ref 4988511 Coil C35-36B+EL296UH070XV36B*+TDR+TXV AHRI ref 8267074 Efficiency 96 AFUE Efficiency 11.0 EER, 14 SEER Heating input 66000 Btuh Sensible cooling 24780 Btuh Heating output 62000 Btuh Latent cooling 10620 Btuh Temperature rise 49 °F Total cooling 35400 Btuh Actual air flow 1180 cfm Actual air flow 1180 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Wtr CI 22 422 231 14 13 Mstr Bath 317 4523 1207 148 67 Owners Suite 281 3088 2422 101 135 Bdrm 2 159 2818 1985 92 111 CI 2 30 75 39 2 2 Bdrm#6 140 3165 1718 103 96 CI 6 17 274 60 9 3 Loft 195 1840 609 60 34 Up Lndry 138 2602 1489 85 83 Hall 203 1053 2336 34 130 CI 3 18 45 23 1 1 Bdrm# 3 161 2891 2371 95 132 Stairs 134 0 0 0 0 Cl 4 34 924 ` 367 30 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 wrightsols i Right-Suite®Universal 2017 17.0.14 RS000902 Page 1 AM ...Heating,4872 Steeplechase Way,Eagan,MN.nip Calc=MJ8 Front Door faces:SW Bdrm 4 215 4936 2891 161 161 HII Clst 19 46 24 2 1 Dress Rm 42 104 54 3 3 Upr Bath 69 1171 410 38 23 Dress Rm. 28 514 187 17 10 Ba 59 729 281 24 16 CI 5 16 236 56 8 3 Bdrm 5 141 1954 1669 64 93 Wtr Cl. 25 843 325 28 18 Uppr Bath 125 1833 429 60 24 2nd Floor Zone 2586 36085 21184 1180 1180 Other equip loads 17294 3511 Equip. @ 1.00 RSM 24695 Latent cooling 8213 TOTALS 2586 53380 32908 1180 1180 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 Page 2 AM ht o Right-Suite®Universal 2017 17.0.14 RSU00902 ...Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW Load Short Form Job: Anand Residence,4872... 4 Wrtht$Qf Date: December 1 ,2016 Main Zone By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... Project Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Design Information Htg Clg Infiltration Outside db (°F) -15 88 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 85 13 Fireplaces 1 (Tight) Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/lb) 32 29 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade MERIT 90 Trade MERIT Model ML193UH110XP60C-* Cond 13ACXN060-230-** AHRI ref 4792833 Coil C35-49C++TDR+TXV AHRI ref 8267170 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating input 110000 Btuh Sensible cooling 40250 Btuh Heating output 104000 Btuh Latent cooling 17250 Btuh Temperature rise 51 °F Total cooling 57500 Btuh Actual air flow 1917 cfm Actual air flow 1917 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Bar 77 260 0 9 0 Fmly Rm/Theatr 291 2781 3388 99 179 Billard Rm 288 1466 1266 52 67 Clst 21 670 77 24 4 Lw hll 87 532 6740 19 356 Lw Bath 73 283 0 10 0 Bdrm 7 208 1741 1174 62 62 LN 10 18 0 1 0 Strs 113 1471 617 52 33 Elev. 28 46 26 2 1 Entry 114 2060 762 74 40 Kitchen 449 3065 3092 109 163 Pntry 46 1391 312 50 16 Dining Rm 156 2130 2777 76 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 ..., 'PkW#11�11itso RightSuite®Universal 2017 17.0.14 RS000902 Page 3 ACCN ...Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW Great Rm 431 4657 3532 166 186 Stairs. 124 975 155 35 8 Mud Rm 186 1748 451 62 24 Living Rm 174 4875 2822 174 149 Bath 50 697 216 25 11 CtCI 30 540 107 19 6 Chse 18 266 30 9 2 Office 63 27 507 1 27 Chase 11 94 9 3 0 Lin 8 13 0 0 0 Sun Rm 156 1825 2335 65 123 Elev 29 318 33 11 2 Sport Court/Exerc 1029 19739 5896 705 311 Main Zone 4270 53690 36323 1917 1917 Other equip loads 21201 3843 Equip. @ 1.00 RSM 40166 Latent cooling 13507 TOTALS 4270 74891 53673 1917 1917 • Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. fit. 2016-Dec-05 16:02:25 wnghtsoft Right-Suite®Universal 2017 17.0.14 RS000902 Page 4 ...Heating,4872 Steeplechase Way, Eagan, MN.rup Calc=MJ8 Front Door faces:SW Building Analysis Job: Anand Residence,4872... wrightsof gDate: December 1 72016 2nd Floor Zone By: Anthony Aversa Plan: 4872 Steeplechase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email:manualj@webrepshvac.com Web:wnnv.webrepswholesale.com License:... Pro'ect Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Design Conditions Location: Indoor: Heating Cooling Minneapolis/St.paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 31.7 28.7 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 18 ( M ) Method Simplified Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Tight) Heatin • Component Btuh/ft2 Btuh % of load Walls 5.2 9264 17.4 Glazing 22.9 6363 11.9 Walls Humidification Doors 0 0 0 Ceilings 1.8 4541 8.5 Ventilation Floors 1.9 356 0.7 Glazing Infiltration 2.3 4750 8.9 " Ducts 10811 20.3 Piping 0 0 Ceilings Humidification 5495 10.3ther, Ventilation 11799 22.1 In Iltratlon Ducts Adjustments 0 Total 53380 100.0 Coolin • Component Btuh/ft2 ' Btuh % of load Walls 1.3 2256 9.1 Glazing 14.7 4071 16.5 Walls Blower Doors 0 0 0 Ventilation Ceilings 1.0 2629 10.6 Glazing Floors 0 0 0 �°` Infiltration 0.2 387 1.6 ,1_ Internal Gains Ducts 6556 26.5 Ventilation 1805 7.3 Ceilings Internal gains 5285 21.4 Blower 1707 6.9 Other Adjustments 0 Ducts Total 24695 100.0 Latent Cooling Load = 8213 Btuh Overall U-value = 0.051 Btuh/ft2-°F Data entries checked. W,• htstft2016-Dec-0516:02:25 Right-Suite®Universal 2017 17.0.14 RS000902 Page 1 ..Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW Building Analysis Job: Anand Residence,4872... Wrtghtsof g y Date: December 1 ,2016 Main Zone By: Anthony Averse Plan: 4872 Steeplechase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... Pro'ect Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Design Conditions Location: Indoor: Heating Cooling Minneapolis/St.paul, MN, US Indoor temperature (°F) 70 75 Elevation: 837 ft Design TD (°F) 85 13 Latitude: 45°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 31.7 28.7 Dry bulb (°F) -15 88 Infiltration: Daily range (°F) - 18 ( M ) Method Simplified Wet bulb (°F) - 72 Construction quality Tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Tight) Heatin • Component Btuh/ft2 Btuh % of load Walls 4.4 17595 23.5 Glazing 24.3 12072 16.1 Walls Humidification Doors 33.2 1315 1.8 Ventilation Ceilings 1.8 736 1.0 Floors 1.8 4925 6.6 Infiltration 3.7 8778 11.7 Ducts 8267 11.0 Glazing Piping 0 0 Ducts Humidification 7233 9.7 Other Infiltration Ventilation 13969 18.7 loors Adjustments 0 Total 74891 100.0 Coolin • Component Btuh/ft2 Btuh % of load Walls 0.7 2851 7.1 Walls Blower Glazing 18.4 9128 ' 22.7 Ventilation Doors 10.0 398 1.0 Ceilings 1.0 426 1.1Glazin Floors 0 0 0 g � � Infiltration 0.2 522 1.3 Ducts 2139 5.3 Ventilation 2136 5.3 Internal gains 20860 51.9 Other Blower 1707 4.2 Ducts Internal Gains Adjustments 0 Total 40166 100.0 Latent Cooling Load = 13507 Btuh Overall U-value = 0.057 Btuh/ft2-°F Data entries checked. • 2016-Dec-05 16:02:25 {!1/1"IJfltSi 3 RightSuite®Universal 2017 17.0.14 RS000902 Page 2 ACAIIIKK ..Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW Pro ect Summa Job: Anand Residence,4872... Ad" wr'ightsof ry Date: December 1 ,2016 2nd Floor Zone By: Anthony Averse WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:ewwv.webrepswholesale.com License: ... Pro"ect Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Notes: Anand Residence, 4872 Steeplechase Way, Eagan , MN Desi• n Information Weather: Minneapolis/St.paul, MN, US Winter Design Conditions Summer Design Conditions Outside db -15 °F Outside db 88 °F Inside db 70 °F Inside db 75 °F Design TD 85 °F Design TD 13 °F Daily range M Relative humidity 50 % Moisture difference 29 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25275 Btuh Structure 14628 Btuh Ducts 10811 Btuh Ducts 6556 Btuh Central vent (130 cfm) 11799 Btuh Central vent (130 cfm) 1805 Btuh Outside air Outside air Humidification 5495 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 53380 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24695 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tig-ht) Structure 4679 Btuh Ducts 1068 Btuh Central vent (130 cfm) 2466 Btuh Heating Cooling Outside air Area (ft2) 2586 2586 Equipment latent load 8213 Btuh Volume (ft') 20947 20947 Air changes/hour 0.15 0.08 Equipment total load 32908 Btuh Equiv.AVF (cfm) 52 28 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade ELITE 90 Trade MERIT Model EL296UH070XV36B-* Cond 13ACXN036-230-** AHRI ref 4988511 Coil C35-36B+EL296UH070XV36B*+TDR+TXV AHRI ref 8267074 Efficiency 96 AFUE Efficiency 11.0 EER, 14 SEER Heating input 66000 Btuh Sensible cooling 24780 Btuh Heating output 62000 Btuh Latent cooling 10620 Btuh Temperature rise 49 °F Total cooling 35400 Btuh Actual air flow 1180 cfm Actual air flow 1180 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r wry hts+�lft* 2016-Dec-0516:02:25 RightSuite®Universal 2017 17.0.14 RS000902 Page 1 AM ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW Project Summary Job: Anand Residence,4872... wri htsaft •y Date: December 1 ,2016 Main Zone By: Anthony Averse WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manual]@webrepshvac.com Web:wawv.webrepswholesale.com License:... Pro'ect Information For: Chris Buchanon, Sedgwick Heating 1408 Northland Drive, # 310, Mendota Heights, MN 55120 Phone: 952 881-9000 Email: chrisb@sedgwickheating.com Notes: Anand Residence, 4872 Steeplechase Way, Eagan , MN Desi• n Information Weather: Minneapolis/St.paul, MN, US Winter Design Conditions Summer Design Conditions Outside db -15 °F Outside db 88 °F Inside db 70 °F Inside db 75 °F Design TD 85 °F Design TD 13 °F Daily range M Relative humidity 50 % Moisture difference 29 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 45423 Btuh Structure 34184 Btuh Ducts 8267 Btuh Ducts 2139 Btuh Central vent (154 cfm) 13969 Btuh Central vent (154 cfm) 2136 Btuh Outside air Outside air Humidification 7233 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 74891 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 40166 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 9763 Btuh Ducts 824 Btuh Central vent (154 cfm) 2919 Btuh Heating Cooling Outside air Area (ft') 4270 4270 Equipment latent load 13507 Btuh Volume (ft') 32259 32259 Air changes/hour 0.18 0.07 Equipment total load 53673 Btuh Equiv.AVF (cfm) 97 38 Req. total capacity at 0.70 SHR 4.8 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade MERIT 90 Trade MERIT Model ML193UH110XP60C-* Cond 13ACXN060-230-** AHRI ref 4792833 Coil C35-49C++TDR+TXV AHRI ref 8267170 Efficiency 93 AFUE Efficiency 11.0 EER, 13 SEER Heating input 110000 Btuh Sensible cooling 40250 Btuh Heating output 104000 Btuh Latent cooling 17250 Btuh Temperature rise 51 °F Total cooling 57500 Btuh Actual air flow 1917 cfm Actual air flow 1917 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. "• i 2016-Dec-05 16:02:25 O Right Suite®Universal 2017 17.0.14 RS000902 Page 2 ACCIk ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW 41-wlrightsoftt Right-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:wvwv.webrepswholesale.com License: ... 1 Room name 2nd Floor Zone Wtr CI 2 Exposed wall 254.0 ft 0 ft 3 Room height 8.1 ft 8.1 ft heat/cool 4 Room dimensions 6.3 x 3.5 ft 5 Room area 2586.1 ft2 21.9 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 0.00 = 0.00 0 0-----7---------; 0 0 0 0 '" '' '0 ' '' 0 VAI Frm wall,vnl ext,3 0.061 ne 5.21 1.27 387 363 1888 460 0 0 0 0 --G 2 glazing,clr low-e 0.260 ne 22.10 14.42 24 0 530 346 0 0 0 0 � 2 glazing,clr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 11 W' 15B19-8wc-10 0.044 se 0.00 0.00' 4 0 0 0 ,,,,,----,-E.---;4,==„ 0 0 0 Frm wall,vnl ext,3 0.061 se 8..8-(1:1 1.27 642 508 264,t(!). 644 0 0 0 0 10D-v 0.300 se 0.00 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 11.01 44 28 972 484 0 0 0 0 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 2 .10 15.50 90 23 1989 1395 0 0 0 0 2 glazing,clr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 1 15819-8wc-10 0.044 sw 0.00 0.00 0 0 0 0 ` 0 0 0 0 0 2 glazing,dr low-e 0.290 sw 0.00 0.00' 0 0 0 0 0 0 0 0 VI Frm wall,vnl ext,3 0.061 sw 5.21 1.27 387 363 1888 460 0 0 0 0 - 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 -0 2 glazing,clr low-e 0.290 sw 24.65 16.97 24 5 592 407 - 0 0 0 0 W 15819-8wc-10 0.044 nw 0.00 0.00. 0 0 0 0 0 0 -,Q 0 - 2 glazing,dr low-e 0.290 n w 0:00 0.00? 0 0. 0 0 0 ` 2' r "0 0', -G 4A5 2ovd 0.280 nw 0.00 0.00 0 0- 0 0 0 0 0' Frm wall,vnl ext,3 0.061 nw 5.21 1.27 642 546 2843 692 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 7 0 159 104 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 24 0 530 346 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 5 0 111 69 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 60 0 1479 919 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 I 11D0 0.390 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Frri wall,3/8"wood 0.077 0.00` 0.00! 0 0 0 0 0 I. 0 0 0 R Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 D 1100 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 1,76 1.02 2586 2586 4541 2629 122 22 38 -_ . F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0' 0 0 G F 21A-32t 0.020 1.70 0.00 69 69 116 0 0 0 0 0 F Fir floor,fm1 fir, 0.046 1,97 0.00 122 122 240 0 0 0 0 0 F Flr floor,fmi flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -2 Envelope loss/gain 20525 8955 38 20 12 a) Infiltration 4750 387 0 0 b) Room ventilation • 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 0 0 Appliances/other 3675 0 Subtotal(lines 6 to 13) 25275 14628 38 20 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 257 139 14 Subtotal 25275 14628 295 159 15 Duct loads 43% 45% 10811 6556 43% 45% 126 71 Total room load 36085 21184 422 231 Air required(cfm) 1180 1180 14 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-0S 16:02:25 rig ' Right-Suite®Universal 2017 17.0.14 RS000902 Page 1 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW -41-iivrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Date: December 1 ,2016 2nd Floor Zone By:1n: .1`4111'TZe:CicTiaase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Mstr Bath Owners Suite 2 Exposed wall 37.8 ft 17.0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 317.4 ft 15.0 x 18.8 ft 5 Room area 317.4 ft2 281.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 0.00 0.00 0 0` , --0 f 00 -_- 0 ' '',.,4,' 0 ,-,,,''' ,, 0 . w Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 16 16 84 21 G 2 glazing,clr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 . -G 2 glazing,clr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15B19-8wo-10- T.l.--- 0.044 se 0.00 0.00 0 0 '= 0 0 1„,":-..w--4.,0 ': '0,' ,, ,„,, ';',,,0 ---:',-.fh'11::::''',1,0 NiFrmoDIA‘tiall,vnl ext,3 (c))..(1110 se 8.1101 (1)..F0 0 0 0 0 0 0 0 2 2 glazing,clr low-e 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 Vit 15819-8wo-10 0.044 sw 0.00 --,0.00 0 0 0 0 :,0 0 0 _ 0 1 G 2 glazing,clr low-e 0.290 svv 0.00 ..--0.00 0 0 ' ' 0 0 ,10 0 0 - - 0 V./ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 152 152 791 193 0 0 0 0 -G 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 1riG '15°81911441‘;v1-r1lgw-e , 0.290 nw 24.650 16.970 0 . 2 , 0 8 ,,, , 0 - '',81 1 -, ,,,':-.,,2 - - 2 -G 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 h,q 0 0 0 __ 0 ` "0 0 -G 4A5-2ovd 0.280 nw 0.00 c - 0.00 0 0 '' 0 , 0 0 " ---=-„ 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 154 154 801 195 122 92 476 116 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 30 0 740 459 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 P I PnliTwall,3/8"wood 0.390nw 0.00 8:22_. ._-_ _ 0 0 0 , -8 - 2 ,',:, ,-8 -----7- 0 '',' 2 1--ID *F1r1°I;ONall,3/8"wood 0.0640 n 0.00 0.00 0 0 0 0 0 0 0 2 C Attic.ceiling,aspha 0,021 =- 1,76 1.02 317 ,317 ' -- 557 323 '','Pl',,, 281 28t, - 494 286 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0,020 - 0.00 0.00 0 0 ' "II ----,-=',''t_0 ' 0: , ---0 _ - 0 0 F 21A-32t 0.020 - 1.70 0.00 21 21 36 030 30 51 0 F Fir floor,frm flr, 0.046 = 1.97 0.00: 0 - 0 0 --' 0,...,..._ 0 '!' 0.-f---.7: ,;1,11,,0, ,' '0 F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -85 5 Envelope loss/gain 2185 625 1845 887 12 a) Infiltration 706 58 318 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 . 300 Subtotal(lines 6 to 13) 2891 683 2163 1673 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 277 151 0 0 14 Subtotal 3168 833 2163 1673 15 Duct loads 43% 45% 1355 374 43% 45% 925 750 Total room load 4523 1207 3088 2422 Air required(cfm) 148 67 101 135 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .. .. * vright.soft- • • • Right-Suite®Universal 2017 17.0.14 RSU00902 2016-Dec-05 160225 Page 2 ...Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW wrightseft. Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: ,4'111(rt'leitIll:Crase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Bdrm 2 C12 2 Exposed wall 18.3 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 158.7 ft 7.0 x 4.3 ft 5 Room area 158.7 ft2 29.8 ft2 Ty 1 Construction U-value Or HTM Area (ft2) Load Area (ft2) Load i number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6W 15B19-8wc-10 0.044 ne 0.00 0.00 ' 0 0 _ 0 0 0 " ,0 - 0 0 . VI Frm wall,vnlext,3 0.061 ne 5.21 1.27 57 57 295 72 0 0 0 0 . -0 2 glazing,dr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 11 liCTG 1613a1z971;v1-r1103w-e 8:ti?t,7 0.00 ne 0.00 0 0 0 '2 0 „, „,,„0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 -G 10D-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 -0 2 glazing,cir low-c 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 -(3 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 W 15B19.-8Yuc710 0.044 sw 0.00 0.00 - 0 0 0 - 0 0 0 CV0 G 2 glazing,-,c1r low-e 0.290 sw 0.00 0.00 0 0 0 0 0 , , 0 0 a V./ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -G 2 glazing,cir low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 125719'-8wc-111ng,dr) (C))-(2)t(4.) nw 0.00 .g.2s = 0 0 - " 0 g low-c 0.280 rni:, 0.00 -.6:bo 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 91 61 318 77 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 24.65 15.31 30 0 740 459 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 P FirtnRC0.390 iraii,3/8'wood r''." 0.00 0.00 0 0 - , 0 0 0 _ 9 Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 I--D 11D0 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling,aSpha 0.021 - 1.76 1.02 159 159 279 161 30 30 52 30 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t _-:f" 0.020 - 0.00 0.00 -0 0 '0 ' 0 0 0 CE:"'" 0 F 21A-32t 0.020 - 1.70 0.00 0 0 1 0 0 0 0 0 F Fir floor,frrn flr, 0.046 - 1.97 0.00 0 0 0 0 0 0 0 0 F Fir floor,frm fir, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 - - 6 c)AED excursion 43 -3 Envelope loss/gain 1632 813 52 27 • 12 a) Infiltration 341 28 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 1974 1371 52 27 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1974 1371 52 27 15 Duct loads 43% 45% 844 614 43% 45% 22 12 Total room load 2818 1985 75 39 Air required(cfm) 92 111 2 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightscrit' Ri• •ght-Suite®Universal 2017 17.0.14 RSU00902 2016-Dec-05 16:02:25 Page 3 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW -wrightsoft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Bdrm#6 CI 6 2 Exposed wall 22.8 ft 2.5 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 139.9 ft 2.5 x 6.8 ft 5 Room area 139.9 ft2 16.9 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc 1 0 0.044 ne 0.00 0.00 0 ---''''':,0: 0 0 0° l t , 0 V�/ Frm wall,vnl ext,3 0.061 ne 5.21 1.27 89 65 339 83 0 0 0 0 i--G 2 glazing,clr low-a 0.260 ne 22.10 14.42 24 0 530 346 0 0 0 0 � 2 plazinq,clr low-a 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15619-Swc-10 0.044 se 0.00 ' 0.00' 0 0 0 0 _ 0' 0 0 0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 9(5.) 87 454 111 20 20 105 26 100-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 11.01 8 5 177 88 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 0.000.00 0 0 0 0 0 0 0 0 15B19-8wc-10 0.044 sw 0.00 _ 0.00 0 0 0 0 0' 0 0 0 2 glazing,dr low-e 0.290 sw 0.00_.,--rt.- 0.00' 0 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 aw 5.21 1.27 0 0 0 0 0 0 0 0 �G 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 C 2 glazing,dr low-e 0.290 sw 24.65 16.97 0 0 _ 0 0 0 0 0 0 W 15B19-8wc-10 0.044 nw 0.00 0.00 0 0 0 _o:i= 0 0 0 -G 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0- 0 0 ,..z2.7.-:;:"..,70- -G - 0: -G 4A5-2ovd 0.280 nw 0.00 0.00' 0 0 0 ! 1-, 0 0 0 0 .s-..=;:-=`'.----0, Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 I 1100 0.390 nw 0.00 0.00 0 0 0 0 0 0 0 0 P" Frm wall,3/8"wood 0.077 0,00 0,00 j 0 0 0 0 '` 0 0 ; 0 " 0 11--D Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 �D 1100 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 1.76 1.02 140` 140 d2 42 17• 17 30 17 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 ' Ci 0 F 21A-32t 0.020 - 1.70 0.00 2 2 3 0 0 0 0 0 F Flr floor,fon fir, 0.046 1.97 0.00 22 22 43 0 5 5 10 0 F Fir floor,frm fir, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -148 -5 Envelope loss/gain 1791 622 145 38 12 a) Infiltration 425 35 47 ' 4 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 2217 1186 192 41 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2217 1186 192 41 15 Duct loads 43% 45% 948 532 43% 45% 82 19 Total room load 3165 1718 274 60 Air required(cfm) 103 96 9 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 ^ w "i9htsciftr Right-Suite®Universal 2017 17.0.14 RS000902 Page 4 ..Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW 41-wrightsoft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 Byy: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Loft Up Lndry 2 Exposed wall 11.5 ft 20.3 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 194.8 ft 1.0 x 137.5 ft 5 Room area 194.8 ft2 137.5 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne ! 0.00 0.00' 0 0 0 9 0' 0 0 0 Frm wall,vnl ext,3 0.061 ne 5.21 1.27 18 18 95 23 32 32 169 41 i G 2 glazing,clr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 I-G 2 glazing,dr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 0.00 0.00 0 0` 0 0 0 0 a 0' VJ Frm wall,vnl ext,3 0.061 se 5.21 1.27 75 67 348 85 132 116 602 147 -G 10D-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 22.10 11.01 8 5 177 88 16 10 354 176 -G 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 15619-8wc 10 0.044 sw 0.00 0.00 0 0 0 0 0 G 2 glazing,clr low a 0.290 sw 0.00 0.00:'_ d 0 0 0 0 w Fret wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 G 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 15819 8wc 10 (261:g 044 nw 0.00 0 0 0 0 0 0 d 0 2 glazing clrlow-e 0.290 nw 0.00 0.00° 0 0 0 0 0 0 0 0 4A52ovd 0.280 nw 0.00 0.00 0 0 0 0 0- 0 0 -0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 • 1100 0.390 n•‘.14 w 0.00 0.00 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 0.00 0.00 0 0 0 0 0 0 0' 0' R Fnn wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 D 1100 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C` Attic ceiling,aspha 0,021 - 1.76 1.02 195 195 342 198 138 t 241 ` 140', F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 0,00 0.00 0 0 _ 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 2 2 3 0 F Fir floor,frm fir, 0.040 - 1.97 0.00 57 57 112 0 38 38 75 0 F Fir floor,fnn flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 9 -6 Envelope loss/gain 1074 403 1444 498 12 a) Infiltration 215 18 379 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal(lines 6 to 13) 1289 420 1822 1028 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1289 420 1822 1028 15 Duct loads 43% 45% 551 188 43% 45% 779 461 Total room load 1840 609 2602 1489 Air required(cfm) 60 34 85 83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 444- mirlightsaft" RightSuite®Universal 2017 17.0.14 RS000902 2016-Dec-05 16:02:25 5 ...Heating,4872 Steeplechase Way, Eagan, NA p Calc 1 MJS Front Door faces:SW 9 1111- wriightsoft°. Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:w,wv.webrepswholesale.com License: ... 1 Room name Hall CI 3 2 Exposed wall 0 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 203.4 ft 6.5 x 2.8 ft 5 Room area 203.4 ft' 17.9 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-Bwc4_0 0.044 ne 0.00 0.00 0 00 0 t)'- 0 0 _ W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 ��G 2 glazing,cir low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 0.00' 0.00' 0 0 0 0 }' 0 0 0' Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 10D-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 W 15B19.8wc-10 0.044 sw 0,00 0.00 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.290 Sw 0.00 0.00 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 1577; ) &B19-8wc 10 0,044 nw 0.00. 0.00 0 0 0 0 0 0 0 2 glazing}cir low-e 0.290 nw 0.00 0,00 0 0 0 0 0 0 0 0 4A5 2ovd 0.280 nw - 0.00 0.00 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 • 11 DO 0.390 nw 0.00 0.00 0 0 0 00 0 0 0 P Frm wall,3/8"wood 0.077 0.00 0,00 0 0 0 0= 0. 0 0 0 Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 1.76 1,02' 203 203 357 2€7 18 18 31 18 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 0.00 0.00', 0 0 0 0 0 0 a` 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F Flr floor,frrn fir, 0.046 1.97 0.00 0 0 0 3 0 0 0 0 F Fir floor,frm fir, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -175 -2 Envelope loss/gain 357 32 31 16 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1375 0 Subtotal(lines 6 to 13) 357 1407 31 16 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 380 206 0 0 14 Subtotal 737 1613 31 16 15 Duct loads 43% 45% 315 723 43% 45% 13 7 Total room load 1053 2336 45 23 Air required(cfm) 34 130 1 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wirlightsclift� 2016-Dec-05 16:02:25 RightSuite® •Universal 2017 17.0.14 RS000902 Page 6 ...Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW 4 wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Date: December 1 ,2016 , 2nd Floor Zone By: ft'4141'c'ttl'exi:Aaase Way Web Reps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Bdrm#3 Stairs 2 Exposed wall 15.8 ft 12.3 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 161.1 ft 14.5 x 9.3 ft 5 Room area 161.1 ft2 134.1 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 ''" 0.044 -4d' -:-',--l-L 0.00 ',:::::''0.00 0 , ,,,,,0 -1-. :0 ,1:40:',"':' :, ,0 0 r'11:iii:„-„0 0 ' 0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 24 24 126 31 0 0 0 0 . -G2 glazing,dr low-c 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 , 0 11 W 15B1918We-10 0.044 se 0.00,'': '0.00 0 : 0 0 :ii,::1,1'''0 ' 0 ',,k,'l,',,0 ' '„ .•0 ,l,P,,lili:0,4, NFrm wall,vnl ext,3 0.061 se 5.21 1.27 87 42 219 53 12 12 63 15 1013-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 15.50 45 11 995 698 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 4/ 15B19-8wc-10-' 0.044 sw 0.00 -' "0.60 •0 ,,,, , 0 0 '" 1 ,a--.=,-;-,---:--1 0 _ ',''',0 0:,11,,,P0,:r1kiz -:','''.! :, ,0' 1 G 2 glazing,dr low-e 0.290, sw ,' •0.00 0.00 - 0 0 '' ' 0 -- 0 --- '•,l,0`,1,,,,,0 --,- (---,-;:::-,..0 0 --:--,'..--,,-,-;--0 VI Frm wall,vnj ext,3 0.061 sw 5.21 1.27 16 16 84 21 75 51 265 65 -G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 24.65 16.97 „r 0 0 0 _,:_ _0 ,,,, 24_ ,,,,,_ _.„,:::_5__::,:, :::„,,,,592 _,::,„ 407 1581$ -kl-Povit-e •:- -- g'.(/'9t fillIZ 0.00. 0.00 -T--'2- _,--- 0 :2- ---fz-- 0 - -2 ,::' i, 7:71.-kfite---:---4.--4;2 '.----', ,,,,'-g 4A5-2ova = 0.280 nw 0.00 0.00 0 - ---=:--0, '''0, ''' 0 a , ,L,:',::-a TIPS;73-jr-A) :,„;',,,i',1',,,0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 12 12 63 15 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,cir low-c 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 • 11D0 0.390 nw 0.00 0.00 0 0 0 0 0 , 0 0 0 P Frill wall,3/&wood 0.077 ' 0.00 0.00 0 0 • 0, 0 0 "1•,,, ,,,0, ,, ,, ,, ,,0 , '-','0 9 Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 I--D 11D0 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling,aSpha 0.021 '-' • 4.76 1.02 161 161 ',283 164 134 "''',,1 134 , 236 ,,",• tat F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 0,00 0.00- '',":0 0 0 ,0 :q:,,k 0 0 0 0 F 21A-32t 0.020 - 1.70 0.00 13 13 23 0 0 0 1 0 F Fir floor,frm fir, ' 0.046 - 1.----97--- , '0100,' - 0 ' ,0 0 0 ' ''','',:,,,'',,0 0 0--- -',:',,,,,If F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 117 129 Envelope loss/gain 1730 1083 1219 768 12 a) Infiltration 295 24 229 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 2025 1637 1448 786 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -1448 -786 14 Subtotal 2025 1637 0 0 15 Duct loads 43% 45% 866 734 43% 45% 0 0 Total room load 2891 2371 0 0 Air required(cfm) 95 132 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 Right-Suite®Universal I 2017 17.0.14 RSU00902 Page 7 Heating,4872 Steeplechase Way,Eagan, MN.rupCalc=MJ8 Front Door faces:SW 4 wrlghtsol Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name CI 4 Bdnn 4 2 Exposed wall 4.3 ft 34.8 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 8.0 x 4.3 ft 1.0 x 214.5 ft 5 Room area 34.0 ft2 214.5 ft2 Ty Construction U-value Or HTM Area (ft') s Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 0.00 0.00 0 0 0 0 ! 0 �£ �. 0 0 T__2Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 59 59 306 74 2 glazing,dr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 0.00 0.0(x` 0 0 4 0 0 4 U Oi V Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 113 68 356 87 - 100-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,dr low-c 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-c 0.260 se 22.10 15.50 0 0 0 0 45 11 995 698 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 15B19-8wc-10 0.044 sw 0.00 0.00 0 0 - 0 0 0 0 0 0 G 2 glazing,cIr low a 0.290 sw 0.00 0.00' 0 0 0 0 0' 0 0' Frm wall,vnl ext,3 0.061 sw 5.21 1.27 34 34 179 44 109 109 569 139 2 glazing,clr low-c 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 15B 19-8wc-10 0.044 nw 0.00 0.00 0 0 U 0 0 0 0 0 it-CCI 2 glazing,cir low-e 0.290 nw 0.00. 0.04 0 0 0 0 0 (1 0 0 4A5-2ovd 0.280 nw 0.00 0.00', 0 0 0 0 0' 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 I11 DO 0.390 n'-iv w 0.00 0.00 0 0 0 0 0 0 0 0 P': Fret wall,3/a woad 0.077 0.00 0.00 O 0 0 0 f : 0 0 11ID Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 �D 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Atticceiling,aspha = 0,021 1.761-.02' 34 34 60 35 215; 215 377 218 F 21 A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21 hS2t 0.020 - 0.00 0.00 0 - 0 0 0 t- 0 0 0 0 F 21A-32t 0.020 1.70 0.00 0 0 0 0 0 0 0 0 F+ Fir floor,frm fir. 0:046 1...97 0.00 0 0 0 0 0' F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -9 86 Envelope loss/gain 239 69 2602 1'302 12 a) Infiltration 79 6 650 53 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 300 Subtotal(lines 6 to 13) 318 75 3252 1885 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 329 178 205 112 14 Subtotal 647 254 3457 1996 15 Duct loads 43% 45% 277 114 43% 45% 1479 895 Total room load 924 367 4936 2891 Air required(cfm) 30 20 161 161 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 RightSuite®Universal 2017 17.0.14 RS000902 Page 8 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW wrightsoft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepsviholesale.com License:... 1 Room name HII Gist Dress Rm 2 Exposed wall 0 ft 0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 9.3 x 2.0 ft 9.3 x 4.5 ft 5 Room area 18.5 ft2 41.6 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 115819-8wc 10 0.044 ne 0.00 0.00 0 0 0 0 0 0 ,';'"'C'10 ,0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . -G 2 glazing,clr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 1519-8wc-10 0.044 se 0.00 0.00 0 0 0 0 0' 0 0 0' UJ Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 - 100-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 -C 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 V4/ 15319-8wc-f0 0.044 sw 0.00 0.00 0 0 0 _ 0 0' 0 0 0 L G 2 glazing,cls low-c 0.290 sut 0.00 0.001 d 0 0 to 0 0 0` 0' yJ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 i�CG 2 glazing,clr low-a 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low a 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 15B19-8wc-10 0.044 nwr 0.00 0 0 0 0 = 0 0 0 2 glazing,clr low-e 0.290 nw 0.00' 0.00 0 0 0 0 0 0 0 0 4A5-2ovd 0.280 nw 0.00 0.00 0 0 E1 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 I 1100 0.390 nw 0.00 0.00 0 0 0 0 0 0 0 0 P' Frm wall,3/8'woad 0,077 0.00 0.00' 0 0. 0 0 0 0 = 0: Frm wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 D 1100 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C' Attic ceiling,aspha 0.021 1.76 1.02' 19 49 32 19 = 42 42 73 42 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 0.00 0.00'': 0 0 0 0 ':' ., 0 0 0 _ 0': F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F Fir floor,frm fir, 0.046 - 1.97 0.00 0: = 0 0 0 0 0 0 0 F Fir floor,frm flr, 0.046 - 0.00 0.00 0, _ 0 0 0 0 0 0 0 6 c)AED excursion -2 -5 Envelope loss/gain 32 17 73 38 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 32 17 73 38 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32 17 73 38 15 Duct loads 43% 45% 14 7 43% 45% 31 17 Total room load 46 24 104 54 Air required(cfm) 2 1 3 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W1 teas 2016-Dec-05 16:02:25 9 Right-Suite®Universal 2017 17.0.14 RS000902 Page 9 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW 4 writjhtsaft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Date: December 1 ,2016 2nd Floor Zone Plan: '4111Wale,11:0,aase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswtiolesale.com License: ... 1 Room name Upr Bath Dress Rm. 2 Exposed wall 9.3 ft 4.0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 9.3 x 7.5 ft 4.0 x 7.0 ft 5 Room area 69.4 ft2 28.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne-f......:.47-'EO;00 0.00 0 0 0 0 0 ''0 , ,'','0- ', 0 Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . \1 2 glazing,cir low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 11 W 1 ji3a4n-,;,1%:vd=rflt)w--9- g.. 94?t ns:- - 8...8g --3:22 0 0 = 0 ___ 2 , 0 2 , ,, _ __ 2 Frm wall,vnlext,3 0.061 se 5.21 1.27 75 67 348 85 32 28 148 36 10D-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 11.01 8 5 177 88 4 3 88 44 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 Vr--G 25g17118gv,vnc-ir11(13ow-e 2:3 (1, sw,„ 0.00 0.00 0 0 0 , 2 ==_ _'',3 '''''''''',:'-'-----7 0 ' ' ' '''' W Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazino,clr low-e 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 ‘1 15B19-8wc-10 9.9414 nw ._ .:;,Q.„00 ; 0.00 0 0 , 0 0 ,,,,9 ,,, ,, 0 cy, :' , g -,1.??!..f.tia-1,1 dr low-O 0.290 0.280 nw'At -1:1111'7.1:1110.0.gg 111 ,2:22 0 0 ' 0 (u) iu) '', `0' 0."--- :„,, a Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.260 nw 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,cir low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 I 11g1:1:1a0zing,cir low-e 0.300 1,1-,", 0.00 0.00 0 0 0 0 0 0 0 2 P Frm wall,3/8"wood 0.077 - 0.00 0.00 -0 0 0 -0---.7.-- _.--7-:.---:-.=--_--47--, 0 0 0. R--D •FtrinlIDOAlall,3/8" wood 13:32`, n 0.00 0.00 0 0 0 0 0 0 0 2 C Attic ceiling,aspha 0.021 - 1..76 1,02 69 ' 69' 122 71 28 '' 11, -,28 ,"'' 49 28 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - aoo ' aoo 0 0 0 a --,---...,o 0 0 o F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F Fir floor,frm fir, 0.046 - -- 1.97 : 0.00 0 0 0 0 1 0 0 0 0 F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 26 14 Envelope loss/gain 647 269 285 123 12 a) Infiltration 173 14 75 6 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 820 283 360 129 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 820 283 360 129 15 Duct loads 43% 45% 351 127 43% 45% 154 58 Total room load 1171 410 514 187 Air required(cfm) 38 23 17 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 uvrigtitsoft' Right-Suite@ Universal 2017 17. .0 14 RSU00902 Page 10 Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW wrightsoft° Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Ba CI 5 2 Exposed wall 5.3 ft 2.3 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 5.3 x 11.3 ft 2.3 x 7.3 ft 5 Room area 59.1 ft' 16.3 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 0.00 0.00 0 0 0 0 0 - -wrightsaft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... 2nd Floor Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswtiolesale.com License: ... 1 Room name Bdrm 5 WtrCl. 2 Exposed wall 11.8 ft 7.0 ft 3 Room height 8.1 ft heat/cool 8.1 ft heat/cool 4 Room dimensions 1.0 x 141.2 ft 7.0 x 3.5 ft 5 Room area 141.2 ft2 24.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 0.00 0.00 0 0 0 (i £ 0 0 0 . Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . 2 glazing,clr low-e 0.260 ne 22.10 14.42 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15619 8wc10 0044 se' 0.00 0.00 0 0 0 0=_ 0 0 0 0' W Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 - 10D-v 0.300 se 0.00 0.00 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-e 0.260 se 22.10 11.01 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -C 2 glazing,clr low-e 0.260 se 22.10 15.50 0 0 0 0 0 0 0 0 y�-G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 1 15B19.8wc1 O 0.444 sw €.00 0.00 0 0 0 0 0 0 1 0 G 2 glazing,clr low a 0.290 sw 0.00 0.04 0 0 0 0 0 0 �✓ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 �--G 2 glazing,clr low-c 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 Iii 2 glazing,clr low-e 0.290 sw 24.65 16.97 0 0 0 0 0 0 0 0 i/1/ 15B19-8wc-10 0.044 nw 0.00 000 0 0 0 0 0 0 0 0 II----GG 2 glazing,dlr lowe 0.290 nw 0.00 0.00 0 0 0 0 { 0 0 0 4A5-2ovd - 0.280 nw 0.00 0.00 0 0 0 0 0 0 0 01 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 95 71 370 90 57 49 258 63 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 0 0 7 0 159 104 2 glazing,dr low-e 0.260 nw 22.10 14.42 24 0 530 346 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.300 nw 0.00 0.00 0 0 0 0 0 0 0 0 • 11 DO 0.390 nw 0.00 0.00 0 0 0 0 0 0 0 0 P Fret wall,3/8 wocd r 0.077 0.00' 0.00 0 0 0 0 4_ 0 0 0'' R Fmi wall,3/8"wood 0.064 - 0.00 0.00 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 C Attic ceiling;aspha 0.021 1.76' 1.02 'f4T 141 248 144 25 25 43 25' F 21 A-32t 0.020 - 0.00 0.00 0 0 0 0._ 0 0 0 0 F 21'A-32t 0.020 - 0.00' 0.00 0 0 0 0. 0 0 0 0.. F 21 A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F Fir floor,frm fir, 0.046 1.97' 0.00 0 0 0 0 '' 0 0 0 0; F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 25 22 Envelope loss/gain 1149 604 460 214 12 a) Infiltration 220 18 131 11 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 1369 1152 591 225 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1369 1152 591 225 15 Duct loads 43% 45% 585 517 43% 45% 253 101 Total room load 1954 1669 843 325 Air required(cfm) 64 93 28 18 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ws 2016-Dec-05 16:02:25 Right-Suite®Universal 2017 17.0.14 RS000902 Page 12 ...Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW writihtsaft Rig ht-J®Worksheet Job: Anand Residence,Date: 4872 Stee... December 1 ,2016 2nd Floor Zone WebReps LLC. By: cSitiefell:Chaase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Uppr Bath 2 Exposed wall 17.5 ft 3 Room height 8.1 ft heat/cool 4 Room dimensions 1.0 x 124.6 ft 5 Room area 124.6 ft2 Ty Construction U-value Or HIM Area (ft2) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15819-8wc-10 0.044 ne 0.00 0.00 0 0 0 ' 0 Frm wall,vnl ext,3 0.061 ne 5.21 1.27 91 91 474 116 2 glazing,dr low-e 0.260 ne 22.10 14.42 0 0 0 0 11 W 15Ela1tn-ii1V-r113)w-a (0):,(710ne 4. 0.00 0.00 W Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 -G 1OD-v 0.300 se 0.00 0.00 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 11.01 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 -C 2 glazing,dr low-e 0.260 se 22.10 15.50 0 0 0 0 -G 2 glazing,dr low-a 0.260 se 0.00 0.00 0 0 0 0 G 25g11a1:14v,vcc-1;11)ow-e 0.044. sw g:gg 0.00 rs_ 0 - - 1/7/ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 -G 2 glazing,dr low-c 0.290 sw 0.00 0.00 0 0 0 0 -G 2 glazing,dr low-a 0.290 sw 24.65 16.97 0 0 0 0 15819-8wc40 0.044 nw 0:00 - -0 0 0 2 glazitig,clrlow-e 0.290 nw 0:00 --0.00 0 0'=_ 0 0 4A5-2ovd 0.280 nw 0.00 ' 0.00 0 0 0 - 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 51 51 264 64 2 glazing,dr low-e 0.260 nw 22.10 14.42 0 0 , 0 0 2 glazing,dr low-a 0.260 nw 22.10 14.42 0 0 0 0 2 glazing,clr low-a 0.290 nw 24.65 15.31 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 2 glazing,dr low-e 0.300 nw 0.00 0.00 0 0 0 0 P I Flrg° 0.390 wall,3/82 wood- n'-N 0.00 0.00 0 0 0 g D .F1 rini13(rall,3/8"wood 2..s2r4, r; 0.00 0.00 0 0 0 0 C Attic ceiling,aspha = 0.021 --- 1,76 1.02 125 125 219 127 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 • 21A-32t 0:020 - 0.00 0.00 0 =- 0 0 0F Flirt3or,2t fan fir, 0.046 1:4? F Fir floor,fr-rb fir, 0.046 - 0.00 0.00 0 0 0 0 - , 6 c)AED excursion -37 Envelope loss/gain 957 269 12 a) Infiltration 327 27 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1284 296 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1284 296 15 Duct loads 43% 45% 549 133 Total room load 1833 429 Air required(cfm) 60 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WrightSaft" • UniversRight-Suite®Univeal 2017 17.0.14 RSU00902 2016-Dec-05 16:02:25 i Page 13 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW ` wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 Byy: Anthony Avers, WebReps LLC. Pfan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Main Zone Bar 2 Exposed wall 336.9 ft 5.3 ft 3 Room height 10.7 ft 9.0 ft heat/cool 4 Room dimensions 5.3 x 14.8 ft 5 Room area 4269.6 ft' 77.4 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne-J 0.14 245 245 750 35 0 €k - I 41-wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Fmly Rm/Theatr Billard Rm 2 Exposed wall 21.5 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 19.8 x 14.8 ft 25.0 x 11.5 ft 5 Room area 291.3 ft' 287.5 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 3.06 0.14 16 16 43 0 0 0 0 0 VI Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 t� 2 glazing,clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 N 11 W 15B19-8wc-10 0.044 se 3.08' 0.15 0 0 0 0 0' 0 0 0' Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 Vf! 15B19-8wc-10 8:8'4i4)'-lit .044 sw'= 2.62 0.04 0 0 0 0 G 2 glazing,clr low-e 0.290 sw 24.65 16.68 0 0 0 0,! 0 0 0'' VJ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B19.8wc 10 0.044 nw 2.75 0.09 178 92 163 0 0 0 0 0 2 glazing,clr low-e 0.290 rtw 24.65 15.31 45 0 1109 688 0 0 0 0 1-0 4A5-2ovd 0.280 rtw 23.80 15.74 41 0 971 642 0 0 0 °0', Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 I 11D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 6.57 0.83' 0 0 0 0 0--------- 0 .0 '' "0 R Frm wall,3/8"wood 0.064 5.43 0.69 0 0 0 0 180 180 977 124 �--D 11 DO 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 Attic ceiling,aspha 0.021 1.76 1,02' 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 0.00 291 291 495 0 288 288 489 0 F 21A-32t 0.020 1.70 0,00' 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir;floor,frm'fir, 0.046 - 0.00 0,00' =0 0 , 0 0 0 0 '0 0 F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 z 0 0 0 0 0 0 6 c)AED excursion 457 -58 Envelope loss/gain 2781 1788 1466 66 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1600 1200 Subtotal(lines 6 to 13) 2781 3388 1466 1266 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2781 3388 1466 1266 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 2781 3388 1466 1266 Air required(cfm) 99 179 52 67 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ..i htsoft" 2016-Dec-0516:02:25 RightSuite® •Universal 2017 17.0.14 RS000902 Page 15 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW - wrigbtsoft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Gist Lw hll 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 7.5 x 2.8 ft 1.0 x 87.1 ft 5 Room area 20.6 ft2 87.1 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - 6 W 15B19-8wc-10 0.044 ne 3.06 0.14 --.,.-..-_-_,==.0 0 0 il 4 wrightsoflr Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Lw Bath Bdrm 7 2 Exposed wall 6.5 ft 29.3 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.5 x 11.3 ft 12.3 x 17.0 ft 5 Room area 73.1 ft2 208.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc--10 0.044 ne 3.06' 0.14 0 0 0 = 0 0 07-7-7.,;--.-=:-::---T- -0 T___2�/ Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 ii-�� 2 glazinq,clr low-c 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15819-8wc-10 0.044 se 3.08 0.11 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 1,6 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazinq,clr low-e 0.260 se 22.10 1 )..(8)(7 0 0 0 0 0 0 0 f 15B19-8wc"10 0.044 sw 2.62 0.00 0 ` D 0 0 ._-__,-. 5---.3 1153 416 0 G 2 glazing,dr low-e 0.290 sw 24.65' 16.68 0 0 0 0 0' 00 0 V/ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B19-8wc-10 0.044 nw 2.75 0.09 59 59 159 0 = 110 80 188 0 2 glazing,clr low-c 0.290 nw 24.65 15.31 ▪ 0 0 0 0 30 0 740 459 4A5-2ovd 0.280 nw 23.80 15.74 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 11D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"Wood 0,077 = 6.57 0.83 ▪ 0 0,.."7- ----a,,_-_-_-__00 0 0 0;' 0 1113 Frm wall,3/8"wood 0.064 - 5.43 0.69 0 0 0 0 0 0 0 0 �D 11 D0 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 G Attic ceiling,aspha 0.021 1-76 1.02 0 0 0 0 25 25 44 26' F 21A-32t 0.020 - 1.70 0.00 73 73 124 0 208 208 354 0 F 21A-32t - 0,020 1.70 0.00 0 0 0 0 0': ,'1,',0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Elf'floor,frm;flr, 0.046 0.00 0.00 0 0 0 0 '' 0 0 0 0 F Fir floor,frm fir, 0.046 - 1.97 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 159 Envelope loss/gain 283 0 1741 644 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 300 Subtotal(lines 6 to 13) 283 0 1741 1174 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 283 0 1741 1174 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 283 0 1741 1174 Air required(cfm) 10 0 62 62 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r'i htsoft- 2016-Dec-05 16:02:25 RightSuite®Universal 2017 17.0.14 RS000902 Page 17 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name LN Strs 2 Exposed wall 0 ft 9.3 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 10.4 ft 12.3 x 9.3 ft 5 Room area 10.4 ft' 113.3 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-Bum?0 0.044 ne 3.06 0.14 0 0 0 0 0 0 0 0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . -0 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0:g:(21. .290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0 044 se 3.08 0.1,5 0 0 0 0 0 0 0 0' VJ Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 -G 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 - 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-c 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 W 15B19-8wc-10 0.044 sw 2.62 0.00 0 0 0 0 83 62 146 0 G 2glazing,cir low-e 0.290 sw'; 24.65 16.68 0 0 0 Q 22 5 532 360' W Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 VfJ 15B19-Swc-10 0.044 nw 2.755 0.09 0 00 0 0 0 = # 0 IL CG 2 glazing,clr low-e 0.290 nw 24.65 15.3' 0 Q` Q 4 . 0 0 U 0 4A5-2ovd 0.280 nw 23.80 15.74 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 I 1100 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Fat wall,3/6'wood! 0.077 6.57 0.83 0 0 0 0 0 0 0 0 q Frm wall,3/8"wood 0.(64 5.43 0.69 0 0 0 0 110 110 599 76 �D 11 DO 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 1,78 102 0 0 0 0 1 11 _ 1 F 21A-32t 0.020 - 1.70 0.00 10 10 18 0 113 113 193 0 F 21A-32t 0.020 1.70 0.00 a 0 0 Q= 0. 0 0 0' F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir floor frrn flr, 0.046 0.00 0.00 = 0 0 0 0 0 0 0 1 F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 180 Envelope loss/gain 18 0 1471 617 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 18 0 1471 617 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18 0 1471 617 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 18 0 1471 617 Air required(cfm) 1 0 52 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsaft2016-Dec-0516:02:25 Right-Suite®Universal 2017 17.0.14 RS000902 Page 18 ..Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW - =wrightsoft Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Elev. Entry 2 Exposed wall 0 ft 6.8 ft 3 Room height 17.7 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 5.0 x 5.5 ft 1.0 x 114.2 ft 5 Room area 27.5 ft2 114.2 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne3.06 0.14 0 0 0 0 i 0 0 0 . Vr/ Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . -0 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 3.08 0.15 0 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 61 19 101 25 -0 10D-v 0.300 se 25.50 12.22 0 0 0 0 42 8 1071 513 -G 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 G 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 22.10 15.67 00 0 0 0 0 0 0 15B19-8wc-10 0.044 sw 2.62 0.001 0 _ 0 _ 0 0 0 0 0 0 G 2'glazing,clr low-e 0.290 sw 24.65 16.68 0 0 0 0 0 0 0 0 V,J Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B19.8wc-1O 0.044 nw 2.75 0.00 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 1 0 4A5-2ovd 0.280 nw! 23.80 15.74` 0 0 0 0 0 €F- 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 U 11 DO 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0,077 - 6.57 0.83 0 0 0 0 0 0 R Frm wall,3/8"wood 0.064 - 5.43 0.69 0 0 0 0 0 0 0 0 �D 11 DO 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 - 1.76 1.02` 26 26 46 27 5 5 9. 5 F 21A-32t 0.020 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-321 0.020 - 1,70 0.00 0 0 0 0'i 0 0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 00 0 0 F Fir floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 _ 0 0 F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 0 0 109 109 214 0 6 c)AED excursion -1 135 Envelope loss/gain 46 26 1395 678 12 a) Infiltration 0 0 229 14 b) Room ventilation 0 0 0 , 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 46 26 1624 692 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 46 26 1624 692 15 Duct loads -0% 0% 0 0 27% 10% 436 70 Total room load 46 26 2060 762 Air required(cfm) 2 1 74 40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W htsts t" 2016-Dec 05 16:02:25 RightSuite0 Universal 2017 17.0.14 RS000902 Page 19 ...Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW wrightsoft Right-J®Worksheet Job: Anand Residence,: 4872 Stee... DateDecember 1 ,2016 Main Zone By: Anthony'131:gaase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License:... 1 Room name Kitchen Pntry 2 Exposed wall 18.9 ft 7.0 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 1.0 x 448.6 ft 7.0 x 6.5 ft 5 Room area 448.6 ft' 45.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 -- 0.044 ne 3.06 0.14 7 0 - 0 0 - - A 0 ' " , 0 0 0 W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 18 18 95 23 0 0 0 0 . -G 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc=10 0.044 se 3.08 0.15 0 0' 0 0 ,0 0 0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 155 123 640 156 64 56 294 72 -G 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 -C 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 7 3 159 103 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 cil;a1zn-.1Wgr110)1N-e 0.260 se 22.10 18..070 32 703 498 -,2 0 2 glazing,dr low-e 0.290 sw 24.65 16.68 0 0 0 0 0 - 0 0 0 Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 2 glazing,dr low-a 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 ;5gilit8g7ccill Pow-e 0.0440nwrit,v2i..;2. 12..2? ,S.- 0 0' ' 0 0 0 2 4A5-2ovd 0.28Q nw -23.00 " 15.74 '0 0 •-=""="="0 - 0 0 ""' 0 0 d Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 11D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 - 6.57 0.83 0 0 0 0 0 , '=0,,,"' ''' 0 0 0 0 0 59 59 321 41 9 .7 rin&:v:juall,3/8"wood 2.32,31. r; 33.15 12:2? 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 - 1.76 1,02 5 5 8 5 0 - 0 0 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-321 0.020 - 1,70 0,00 5 ' 5 ", 9 _- -0 18 ' '18 ' 30 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir floOr,frrn flr, - 0.046 - n000 0.00 0 0 0 " 0 0 0 0 i, F Fir floor,frm fir,. 0.046 - 1.97 0.00 161 161 318 0 28 28 54 0 - _ _ - 6 c)AED excursion 88 54 Envelope loss/gain 1772 770 859 270 12 a) Infiltration 644 38 237 14 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 2416 2809 1096 284 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2416 2809 1096 284 15 Duct loads 27% 10% 649 284 27% 10% 295 29 Total room load 3065 3092 1391 312 Air required(cfm) 109 163 50 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. lArrightsaft- Suite®• •ght-Suite®Universal 2017 17.0.14 RSU00902 2016-Dec-05 16:02:25 Page 20 ...Heating,4872 Steeplechase Way Eagan,MN.rup Calc=MJ8 Front Door faces:SW wrightsolt Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Date: December 1 ,2016 Main Zone By: Anthony, teiti:Oiaase Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Dining Rm Great Rm 2 Exposed wall 12.0 ft 37.8 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 1.0 x 430.5 ft 5 Room area 156.0 ft' 430.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 :fie- 3.06 0.14 0 "--0 _ 0 0 0 ' 0 0 . Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . -G 2 glazing,clr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 . -G 2 glazing,clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 3.08 0.15 0 0 0 -0 0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 -G 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-c 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 Vt7G 6c1Ba1z9n-i.iWg111(}3w-e g:(2)1?1 ::1 22.10 15.670 0 0 0 0 0 2 G 2 glazing,dr low-e 0.290 sw 24.65 ' 16.68 0 0 0 =,:"1-- 0 '0 0 0 Fria‘Alzrlilg viClirlt- 241.15 114175 0 0 0 0 152 793 193 2 2 qlazin ,dr low-e g..61.401 iT\4Ali 0.00 0.00 --_-,_-_ 0 0, _ 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 - 0 0 0 01-ir 0 0 4A5-20vd 0.280 23..80 15.74 0 0 0 0 0 -- 0 '7-5-00 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 109 50 259 63 191 111 577 140 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 59 0 1464 910 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 47 0 1166 724 2 glazing,clr low-c 0.300 nw 25.50 15.43 0 0 0 0 33 0 842 509 Ill ° - nw 3 10.025 0 P Fmwall,3/8wood 0.390 : t.; 0 0_ 08 D riliD(Tiall,3/8"wood 0.064n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling.,aspha 0,021 - 1.76 -1.02 0 - 0 0 0 0 '0 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 -4:00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir floor,fml flr, 0.046 - 0.00 0.00 _ = 0 - 0 0 0 -0 0 0 F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 0 0 0 0 0 _0 6 c)AED excursion 280 388 Envelope loss/gain 1723 1253 3378 1956, 12 a) Infiltration 407 24 1279 76 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1500 1500 Subtotal(lines 6 to 13) 2130 2777 4657 3532 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2130 2777 4657 3532 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 2130 2777 4657 3532 Air required(cfm) 76 147 166 186 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 444" wrightsaft' ht-Suite®Unive' rsa I 2017 17.0.14 RSU00902 Page 21 Heating,4872 Steeplechase Way,Eagan, MN.rupCalc=MJ8 Front Door faces:SW - - wrightsoft Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax 888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Stairs. Mud Rm 2 Exposed wall 12.0 ft 4.3 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 1.0 x 123.8 ft 1.0 x 186.4 ft 5 Room area 123.8 ft2 186.4 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 ' _ 0.044 ne 3.060.14 if 0 0 0 0 0 0 0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . -G 2 glazing,clr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0.044 se 3.08 0.15 0 0 0 0' 0 0 0 0 Frm wall,vnl ext,3 0.061 se 5.21 1.27 14 14 71 17 0 0 0 0 1OD-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 y� 2 glazing,clr low-e 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 15819-8wc-10 0.044 sw- 2.62 0:00 0 0 0 U R 0 0 0 G 2 glazing,clr low-e 0.290 sw 24.65' 16.68 0 0 0 0 0 0 0 O' VJ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 82 82 426 104 0 0 0 0 G 2 glazing,dr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 _ 0 0 i/ 15619-8wc 10 0.044 nw 2.75 0.09 0 0 0 0 0 , 0 0 0 iICG 2 glazing,clr low-e 0.290 nw 24.65 .11::;:i1 5.31 0 0 0 0 0 0 U 4A5-2ovd 0.280 nw', 23.80 15.74 0 0 0 0 `r 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 14 14 71 17 39 19 98 24 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-c 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 • 11 DO 0.390 nw 33.15 10.02 0 0 0 0 20 657a-- 57 199 .P Frm wall,3/8"wood 0.077. - 6,57' 0.83 0 0 0 0 4 __?_-__(03, 0` 0', R Frm wall,3/8"wood 0.064 - 5.43 0.69 0 0 0 0 48 28 152 19 ID 11D0 0.390 n 33.15 10.02 0 0 0 0 20 20 657 199 C Atticceiling aspha 0.021 - 1:76'' 1,02 0 0 0 0 23 23023 F 21 A-32t 0.020 1.70 0.00 0 0 0 0 0 0 0 0 F' 21A-32t 0.020 ' 70` 0.04 0 0 0 0 0 0 tf 0 F 21A-32t 0.020 - 0.00 0.00 0 00 0 0 0 0 0 F! Fir floor,frm;flr, 0.046 0.00' 0.00 0 0-- 0 0 0 0 0 a' F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 0 0 0 0 0 0 uc -. 6 c)AED excursion -7 -21 Envelope loss/gain 568 131 1604 443 12 a) Infiltration 407 24 144 9 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 975 155 1748 451 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 975 155 1748 451 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 975 155 1748 451 Air required(cfm) 35 8 62 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. lArrt htsr 2016-Dec-0516:02:25 RightSuiteBn Universal 2017 17.0.14 RS000902 Page 22 ...Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW 4-wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Date: December 1 ,2016 Main Zone Anthonye,t1ZI:se Way WebReps LLC. 1880 82nd Avenue Suite#203,Vero Beach,FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email: manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Living Rm Bath 2 Exposed wall 36.3 ft 6.0 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 1.0 x 174.1 ft 1.0 x 50.4 ft 5 Room area 174.1 ft2 50.4 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 151319-8we-I0 0.044 ne 3.06 0.14 0 0 0 0 0 --- 0 0 Vi Frm wall,vnl ext,3 0.061 ne 5.21 1.27 75 75 391 95 0 0 0 0 . -G 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing.clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15819-8wc-10 0.044 se 3,08 0.15 0 0 0 0 0 0 0 0 Vi Frm wall,vnl ext,3 0.061 se 5.21 1.27 130 98 509 124 0 0 0 0 -G 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 -0 2 glazing,dr low-c 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 15.67 32 8 703 498 0 0 0 0 91 G '215g113Ignag",Iccirl-gw-e - 0.044 24:2i - 0 0 - 0 0tE• '8 2 • Frm wall,vnl ext,3 0.061 2 glazing,dr low-c 0.290 :vvvy 11A75 125 125 651 159 55 49 2531 62 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 ‘16 15B19-8wc-10 0.044 nvir 2.75 0.09 0 LI 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 - 0 - 0 0 0 0 0 4A5-2ovd - 0.280 nw 23.80 - 15.74 0 0 0 0 - 0 0 0 - 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-c 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 I 11D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 - 6.57 0.83 0 0 0 0 0 0 0 ---_- 0 9 Frm wall,I D 318"wood 0.064n 33.15 10.02 0 0 0 0 0 0 • -- Attic ceiling,aspha 0,021 1.76 1,02 15 -15 25 15- _ 0 0 0 Cr F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 0,00 32 32 55 _ 0 0 _ 0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir ,floor,;_.frin flr, 0.046 - 0.00 0.00 0 0 -- 0 0 0 0 --, 0 0 F Fir floor,frm fir, 0.046 - 1.97 0.00 142 142 280 _O 47 47 93 0 - - - 6 c)AED excursion 99 56 Envelope loss/gain 2614 991 494 204 12 a) Infiltration 1228 73 203 12 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1500 0 Subtotal(lines 6 to 13) 3842 2564 697 216 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3842 2564 697 216 15 Duct loads 27% 10% 1033 259 -0% 0% 0 0 Total room load 4875 2822 697 216 Air required(cfm) 174 149 25 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -1411- %AfrightSairr . lit-Suite®Universali2016-Dec-05 16:02:25 Rig2017 17.0.14 RSU00902 Page 23 ...Heating,4872 Steeplechase Way, Eagan,MN.rupCalc=MJ8 Front Door faces:SW wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Ct CI Chse 2 Exposed wall 6.0 ft 0 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 6.0 x - 5.0 ft 5.0 x 3.5 ft 5 Room area 30.0 ft2 17.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15619-8wc-10 0.044 ne 3.06 0.14 0 0 0 0 0 =0 0 0 Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 G 2 glazing,clr low- 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low- 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15619 8wc-10 0.044 se 3.08 0.15 ; 0 0 0 0 ! 7 0 0 0' VJ Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 - 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 -C 2 glazing,dr low- 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,dr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,dr low-e0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 yJ 15B19.8wc 10 0.044 sw 2,62 0.00 0 0 0 = 0 . 0 0 0 0 glazing,clr pow a 0.290 sw' 24.65 16.58 0 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -0 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 15819-8wc:10 0.044 nw 2.75 0.09 0 0 0 0 = 0 0c 0 0 2 glazing,clr low- 0.290 nw 24.65 15.31 0 0 0 0_ 0 0 0 0 4A5-2ovd 0.280 nw', 23.$0 15.74 0 0 0 0 U =0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 55 55 284 69 0 0 0 0 2 glazing,clr low- 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low- 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low- 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low- 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low- 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low- 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 • 11 DO 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 6.570.83 0 0 0 0 '! 0 0 0 0'' R Frm wall,3/8"wood 0.064 - 5.43 0.69 0 0 0 0 46 46 247 31 1-D 11D0 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 G Attic ceiling alpha 0,021 - 1.1.7760 1 0.00 1.42 30 0 30 53 30 0 00 0 ff F 21 A32t 0.020 0 0 0 0 0 0_ F 21A-32t 0.020 - 1.70 0,00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Firfloor,frm flr, 0.046 0.00 0.00 0 0 0 0-- 0 0 0 F Fir floor,frm flr, 0.046 - 1.97 0.00 0 0 0 0 10 10 19 _ 0 6 c)AED excursion -5 -1 Envelope loss/gain 337 95 266 30 12 a) Infiltration 203 12 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 540 107 266 30 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 540 107 266 30 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 540 107 266 30 Air required(cfm) 19 6 9 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41-°"`^^ ` RightSuitee Universal 2017 17.0.14 RS000902 2016-Dec-05 16:02:25 Page 24 ...Heating,4872 Steeplechase Way,Eagan,MN.rup Calc=MJ8 Front Door faces:SW -PP-wr'ightsoftv Rig ht-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 Byy: Anthony Aversa WebReps LLC. Pran: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Office Chase 2 Exposed wall 0 ft 0 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 1.0 x 63.4 ft 7.0 x 1.5 ft 5 Room area 63.4 ft' 10.5 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 3.06 0.14 0 0 0 0 0 0 0 0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 0 0 0 0 . G 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 2 Glazing,clr low-a 0.290 ne 24.65 11..1.15 . 1 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0 044 se' 3.08 0.15 0 0 0 0 0 0 0 0: Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 100-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 G 2 glazing,dr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 V�J 15B19-8wc-10 0.044 sw 2.62 0.00 0 0 0 0 0 0 0 0 G 2 glazing,clr low-e 0.290 sw', 24.65 16.68 0 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -0 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 Glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 V 15819-8wc-10 0.044 nw 2.75 0.09 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 4A5-2ovd 0.280 nw 23.80 15.74 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-a 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-a 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-a 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-a 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 • 1100 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0 077 - 6.57 0:83 0 0 0 0 0 0 0 0' R Frm wall,3/8"wood 0.064 5.43 0.69 0 0 0 0 14 14 74 9 I 0 1100 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling,alpha' 0.021' - 1.76 1.02 0 0 0 0` 0 0 0 0 F 21A-32t 0.020 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 4 4 7 0 F 21 1 -32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F Flr floor,frm flr, 0.046 - 0.00 0.00 0 0 0 0 0 0 0 0 F FIr floor,fmi flr, 0.046 1.97 0.00 14 14 27 0 6 6 13 0 6 c)AED excursion -23 0 Envelope loss/gain 27 -23 94 9 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 300 0 Subtotal(lines 6 to 13) 27 507 94 9 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 27 507 94 9 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 27 507 94 9 Air required(cfm) 1 27 3 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Dec-05 16:02:25 iACAC" . Wrights[sft" RightSuite0 Universal 2017 17.0.14 RS000902 Page 25 4P. ...Heating,4872 Steeplechase Way, Eagan,MN.rup Calc=MJ8 Front Door faces:SW wrightsoft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Lin Sun Rm 2 Exposed wall 0 ft 13.8 ft 3 Room height 9.1 ft heat/cool 9.1 ft heat/cool 4 Room dimensions 3.3 x 2.5 ft 12.0 x 13.0 ft 5 Room area 8.1 ft' 156.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B19-8wc-10 0.044 ne 3.06 0.14 0 0 0 0 0 0 0 0 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 16 16 83 20 . -0 2 glazing,dr low-e 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.290 ne 24.65 15.31 0 0 0 0 0 0 0 0 11 W 15B19-8wc-10 0:044 se 3.08' 0.15 0 0 0 0 0 0 0 0 W Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 0 0 0 0 -0 10D-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 G 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 14/ 15B19-8wc-10 0.044 sw 2.62 0.00 0 0 0 0 0 0 0 0 I G 2 glazing,clr low-e 0.290 sw 24.65 16.68 0 0 0 0 0 0 0 0 VI Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 VfJ 15B19-8wc=10 0.044 nw 2.75 0.09 0 0 0 0 2 0 0 0 I(---GG 2 glazing,clrlow-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 4A5-2ovd 0.280 nw 23.80 15.74 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 109 73 381 93 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 36 0 887 551 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 11D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Fmt wall,3/8"wood 0.077 - 6.57 0.83 0 0 0 0 l 0 0 0 0' 11-D Frm wall,3/8"wood 0.064 5.43 0.69 0 0 0 0 0 0 0 0 �D 11 DO 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0,021 1,76' 1.02 0 0 0 0 0 0 0 0 F 21A-32t 0.020 - 1.70 0.00 0 0 0 0 0 0 0 0 F 21A-32t 0.020 1.70 0,00 0 0 0 0 5 5 8 0 F 21A-32t 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 F Fir floor,frm flr, 0.046 - 0.00 0,00 0 0 0 0 0 0 0 0 F Fir floor,frm flr, 0.046 - 1.97 0.00 7 7 13 0 0 0 0 0 6 c)AED excursion 0 143 Envelope loss/gain 13 0 1360 807 12 a) Infiltration 0 0 466 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1500 Subtotal(lines 6 to 13) 13 0 1825 2335 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13 0 1825 2335 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 13 0 1825 2335 Air required(cfm) 0 0 65 123 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1411- W rigus Si ® iguenversal 2017 17.0.14 RS000902 2016-Dec-05 16:02:25 Page 26 ... Heating,4872 Steeplechase Way,Eagan, MN.nip Calc=MJ8 Front Door faces:SW -PP"vvrightsaft Right-J®Worksheet Job: Anand Residence,4872 Stee... Main Zone Date: December 1 ,2016 By: Anthony Aversa WebReps LLC. Plan: 4872 Steeplechase Way 1880 82nd Avenue Suite#203,Vero Beach, FL 32966 Phone:800-810-3280 Fax:888 971-2999 Email:manualj@webrepshvac.com Web:www.webrepswholesale.com License: ... 1 Room name Elev Sport Court/Exerc 2 Exposed wall 0 ft 104.5 ft 3 Room height 9.0 ft heat/cool 15.5 ft heat/cool 4 Room dimensions 5.5 x 5.3 ft 1.0 x 1029.3 ft 5 Room area 28.9 ft' 1029.3 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 151319-8wc-10 0.044 ne 3.06 0.14 0 0 0 0 230 230 708 35 . W Frm wall,vnl ext,3 0.061 ne 5.21 1.27 0 0 0 0 230 198 1028 250 . G 2 glazing,dr low-c 0.260 ne 0.00 0.00 0 0 0 0 0 0 0 0 -0 2 glazing,clr low-a 0.290 ne 24.65 15.31 0 0 0 0 32 0 789 490 11 W 15B19-8wc-10 0.044 se 3.08' 0.15 0 0 0 0 331 331 1020 51- W Frm wall,vnl ext,3 0.061 se 5.21 1.27 0 0 0 0 68 68 351 86 G 100-v 0.300 se 25.50 12.22 0 0 0 0 0 0 0 0 G 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,clr low-e 0.260 se 22.10 14.34 0 0 0 0 0 0 0 0 - 2 glazing,clr low-e 0.260 se 0.00 0.00 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.260 se 22.10 15.67 0 0 0 0 0 0 0 0 15B19-8wc10 0.044 sw 2.62 0.00 0 0 0` G 2;glazing,clrlow-e 0.290 sw 24.65 16.68 0 0 0 VJ Frm wall,vnl ext,3 0.061 sw 5.21 1.27 0 0 0 0 0 0 0 0 - 2 glazing,dr low-e 0.290 sw 24.65 14.35 0 0 0 0 0 0 0 0 -G 2 glazing,dr low-e 0.290 sw 0.00 0.00 0 0 0 0 0 0 0 0 W 15819-8wc-10 0.044 nw 2.75 0.09 0 0 0 0 380 380 1172 58 - 2 glazing,dr low-e 0.290 nw24.65 15.31 0 0 0 0 0 0 0 0 -C 4A5-2ovd 0.280 nw 23.80 15.74 0 0 0 0 0 0 0 0 Frm wall,vnl ext,3 0.061 nw 5.21 1.27 0 0 0 0 263 231 1204 293 2 glazing,clr low-c 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.260 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 32 0 789 490 2 glazing,clr low-e 0.290 nw 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,dr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.290 nw 24.65 15.31 0 0 0 0 0 0 0 0 2 glazing,clr low-e 0.300 nw 25.50 15.43 0 0 0 0 0 0 0 0 I 11 D0 0.390 nw 33.15 10.02 0 0 0 0 0 0 0 0 P Frm wall,3/8"wood 0.077 - 6.57 0.83 0 0 0 0 0 0 0 0 FlFrm wall,3/8"wood 0.064 - 5.43 0.69 50 50 269 34 227 227 1234 157 D 1100 0.390 n 33.15 10.02 0 0 0 0 0 0 0 0 C Attic ceiling,aspha 0.021 - 1.76 1.02 0 0 0 0 290 290 510 295 F 21A-32t 0.020 1.70 0.00 29 29 49 0 1029 1029 1750 0 F 21A-32t 0.020 1.70 0.00 0 0 0 0 I 0 0 0 0 F 21A-32t 0.020 0.00 0.00 0 0 0 0 0 0 0 0 F FIr floor,frm fir, 0.046 0.00 0.00 0 0 0 0 0 0 0 0 F FIr floor,frm fir, 0.046 1.97 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -1 -6 Envelope loss/gain 318 33 10553 2199 12 a) Infiltration 0 0 3332 198 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 318 33 13885 4397 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 318 33 13885 4397 15 Duct loads -0% 0% 0 0 42% 34% 5854 1498 Total room load 318 33 19739 5896 Air required(cfm) 11 2 705 311 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightso 2016-Dec-05 16:02:25 Right-Suite®Universal 2017 17.0.14 RS000902 Page 27 ...Heating,4872 Steeplechase Way,Eagan, MN.rup Calc=MJ8 Front Door faces:SW 2016 Standardized Concrete Foundation Drawings SCOPE OF WORK: These drawings apply to the construction of cast-in-place concrete foundation walls for typical residential cases. These drawings are not to scale and all conditions are to be verified by the contractor. Means and methods of construction for shoring,water-proofing, insulation,flashing,control and construction joints, and all other non-structural requirements are to be by others in accordance with the Code and standard industry practice. These drawings are valid until the end of 2016. The drawings are to only be used by the contractor noted below or his authorized sub-contractors/clients. These drawings are to be provided to the building inspection department as part of the permit package. INDEX: S1 -Scope, Index,and Certification S2-General Notes S3-Step Footing Detail S4-Frost Wall Detail S5-Lookout Wall Detail S6-Full Height Wall Detail MATERIALS: Reinforcing Steel:Grade 40(40 ksi)for#4 and smaller bars Grade 60(60 ksi)for#5 bars and larger Concrete: Mix design is to be prepared by the concrete supplier to meet the project's requirements Minimum 28 day compressive strength of 4000 psi for walls Minimum 28 day compressive strength of 5000 psi for footings Footings may be 3000 psi if an approved admixture is used to achieve a water and vapor resistance equivalent to 5000 psi Backfill Soil: Sand-30 psf/ft effective lateral pressure Sandy Clay(SC)-45 psf/ft effective lateral pressure Clay-60 psf/ft effective lateral pressure I hereby certify that this plan,specification,or SITE ADDRESS: report was prepared by me or under my direct supervision and that I am a duly licensed professional engineer under the laws of the state Street: of Minnesota. City: State: MN Zip: Craig Oswell,PE(MN#42341) 1/1/2016 Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 Description: Scope of Work, Index,and Certification Phone:612-720-4639 Project# 15.100 Fax:612-886-2966F0P Client Name: Manor Concrete Construction, Inc. www.oswellec.com ,x Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S1 of S6 x, } GENERAL NOTES: 1. Wall thicknesses noted are nominal unless specifically stated otherwise. 2. Maximum wall to footing centerline offset is 2". A minimum of 2"of footing is to extend on each side of the wall. 3. Bar laps when required are to be at least 40 bar diameters for grade 40 and 60 bar diameters for grade 60. 4. Bend horizontal bars or provide matching hooks around all wall corners and intersections. 5. Horizontal bars may be placed anywhere within the wall thickness provided 2"minimum cover is provided. 6. Allowable bar placement tolerance is 1/2". Tying is not required if tolerances are met and maintained. 7. Dowels may be drilled and installed after footing pour unless otherwise noted. Vertical bars may be embedded into footing in place of dowels at the same embedment. Vertical bars and dowels do not need to align. Dowels may be bent down for safety and covering then bent back before wall placement. 8. Sill plate sections require at least two anchors with one within 4"to 12"of each end and at all corners and intersections. Walls less than 24"in length require only one anchor. Sill plates may overhang the face of the wall provided the overhang is not loaded vertically and all anchor bolt/connection tolerances are met. 9. Anchor bolts 1/2"or larger in diameter do not require corrosion protection per IRC section R317.3.1 exception 1. 10. Anchor bolts may be substituted with 1/2"diameter threaded rod epoxy grouted at same spacing with 7"embed. 11. The presence of form oil on the reinforcing is acceptable for the conditions contained in these drawings. 12. Slope grade 6"minimum downward away from foundations within first 10 feet or provide Code adequate swale. 13. Do not backfill until the concrete has reached at least 70 percent of the 28 day concrete strength. Use of adequate shoring is required when the final floor and slab systems are not in place and fully anchored. COLD WEATHER GUIDELINES: The following information is general guidelines for the placement of concrete in cold weather conditions. It is the contractor's responsibility to ensure proper means and methods are followed and that the final in place product is adequate. 1. The contractor is to work with the concrete supplier to obtain a mix design which accounts for the conditions expected. Use of extra cement,early-strength concrete,and accelerators are recommended at temperatures below 20 degrees F. 2. Concrete is to be delivered to the site in a timely manner. 3. Placement of concrete earlier in the day to take advantage of latent heat of sunlight is advised. 4. Do not add additional water. Using water-reducing admixtures is recommended when required. 5. Forms are to be free of snow and ice. Do not place concrete in contact with frozen ground,snow,or ice. 6. Preheating of rebar is not required,however it is to be free of frost,snow,and ice. 7. Use of form blankets or other approved protection is highly recommended for the top of the wall at temperatures below 10 degrees F and for the whole wall when below zero degrees F. Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 Description: General Notes Phone:612-720-4639 I Project# 15.100 Fax:612-886-2966 " Client Name: Manor Concrete Construction,Inc. _ www.oswellec.comb ,., Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S2 of S6 1/1/2016 Adjacent steps are to be placed no closer to either side of the beam section than twice 6'-0"maximum ste• the height of the largest step (beam section) Optional control joint each end of beam section by others (2)bundled#4 horizontal bars `>> "" 7 't top&bottom w/3"min clearance extended at least 4tts� � � � � 24"minimum beyond each end ° ° � � ff �,�° - ��/� � - � � �� � . of beam section(bar length= �bole` step height+4') 401:4 Odr-4.0.1 sk 6"minimum thick cast-in-place Tovstaro a„0,41a concrete foundation wall lk HIGH FOOTING r 1. High footing should be placed 131 - �., ' // at 1-to-1 (45 degree) line,if LOW OOTINt3 / high footing is closer to step V' / than this line, place beam section rebar as if it was at this line as shown FOOTING STEP DETAIL Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#2014`, Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 " Description: Step Footing Detail(NOT TO SCALE) Phone:612-720-4639 Project# 15.100 Fax:612-886-2966 : Client Name: Manor Concrete Construction, Inc. wwwp.oswellec.com Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S3 of S6 1/1/2016 Wall framing by others Sill plate by others w/1/2" diameter anchor bolts w/7" minimum embed&standard washers @ 72"o.c.max or equivalent metal strap anchors Optional slab ledge,maximu * (Anchor bolt clearance between stem height is 12"w/width to match sill plate A edge of both wall and sill plate is to be 2") fj Grade to be at least 6"below top of wall (1)#4 continuous horizontal bar w/in 18"of top of wall — 6"minimum thick cast-in-place £ concrete wall #4 x 2'-0"long dowels @ 72"o.c. max w/5"minimum embed Unreinforced concrete strip footing per Code by others, provide frost protection per Code as required WALKOUT/ SLAB-ON-GRADE FROST WALL DETAIL Note: Maximum unbalanced fill height is 36"for 8"thick wall&48"for 10"wall Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 Description: Frost Wall Detail(NOT TO SCALE) Phone:612-720-4639 Project# 15.100 Fax:612-886-2966 Client Name: Manor Concrete Construction,Inc. www.oswellec.com Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S4 of S6 .2 1/1/2016 Wood floor&wall framing by others Connection of floor members to sill plate to be per Code by others ud 2x6 minimum sill plate w/1/2"diameter anchor bolts w/7"minimum embed&2" wide x 1/8"thick square or round countersunk washers or alternative - A anchor(Anchor bolt clearance between edge of both wall and sill plate is to be 2.5")(see table below for spacing) Grade to be at least 6"below top of wall Exterior top of wall may have a brick 1:4 00,450 Ail ledge provided the stem wall formed is at least 6"thick&no more than 16"high ,7 ,, Continuous#4 horizontal bars,provide at least(2)@8'-0"clear,(3)@ 8'-8" clear,&(4)@ 9'-8"clear,At contractor's option: The lowest wall horizontal bar may be omitted if(2)#4 continuous U horizontal bars are placed in the footing Cast-in-place concrete foundation wall w/#6 or equivalent vertical bars placed 1.5"from inside face,see table below for spacing #4 x 2'-0"long dowels @ 72"o.c.max w/ , 5"minimum embed R Unreinforced concrete strip footing per -'r /Code by others,elevation below slab , may vary as required as 4_ � ^tz. 3; `,' .; BASEMENT WALL DETAIL Clear Height and Soil Type Wall 8'or Less 8'-8" 9'-8" Thickness Sandi SCI Clay Sandi SCI Clay Sandi SC I Clay Vertical Rebar Spacing 8" NA NA NA NA NA 40" NA 36" 28" 10" NA NA NA NA NA NA NA NA 36" 12" NA NA NA NA NA NA NA NA NA Sill Anchor Spacing Bolts 72" 172" 148" 172" 160" 136" 172" 136" 124" Oswell Engineering and Consulting,L.L.C. 1901 E Hennepin Ave,#201 `i,Y .� Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 " ' .a Description: Full Height Wall Detail(NOT TO SCALE) Phone:612-720-4639 - els Project# 15.100 Fax:612-886-2966 � j Client Name: Manor Concrete Construction,Inc. www.oswellec.com Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S6 of S6 ' 1/1/2016 Wall framing by others Sill plate by others w/1/2" diameter anchor bolts w/7" minimum embed&standard washers @ 72"o.c.max or equivalent metal strap anchors �� (Anchor bolt clearance between edge of both wall and sill plate is <----..________to be 2") Grade to be at least 6"below top A ',. of wall (1)#4 continuous horizontal bar Vw/in 18"of top of wall x a1 n ca ,` ";. 6"minimum thick cast-in-place concrete wall N ter all #4 x 2'-0"long centered dowels w/5"minimum Z:11-41 gort wet set or epoxy grouted in Footing elevation may vary below place slab,provide frost protection per Code 6"wall spacing: 36"o.c.max for sand,30"o.c. V 8"thick x 16"wide minimum max for SC,&24"o.c.max for4,,,5,1„, unreinforced concrete strip clayr footing,larger footing width may 8"+wall spacing: be required for specific soil 48"o.c.max for sand,42"o.c. bearing conditions to be r max for SC,&36"o.c.max for determined per Code by others - x clay {, LOOKOUT WALL DETAIL 1901 E Hennepin Ave,#201 . . Oswell Engineering and Consulting,L.L.C. ,, 4 Project Name: 2016 Standardized Concrete Foundation Drawings Minneapolis,MN 55413 u', Description: Lookout Wall Detail(NOT TO SCALE) Phone:612-720-4639 , Project# 15.100 Fax:612-886-2966• j Client Name: Manor Concrete Construction,Inc. www.oswellec.com _,;,,,..;-„--::-:-_:,t7,,,,, ,„ Client Address: 11225 90th Ave N,Maple Grove,MN 55369 Page S5 of S6 „-A;, 1/1/2016 411' City Inspection Dept.Copy City of>;apIl City Forester Copy Applicant/Builder Copy iN r{{..,£ J'xL LOT #: TRS ESERVATION jPL ► tY (BUILDER, PLEASE READ ATTACHMENTS) Development Stone Run Lot Number 1 Block Number 1 Address 4872 Steeplechase Way Builder Norton Homes Phone Number: 763-559-2991 Contact: Pat or Chris or Amy Tree Protection Requirements: Tree Protection Fencing Installed on Site(not required, installed mitigation trees are far uphill from house pad area. Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: Not Required X As Follows: Seven(7)CategoryB trees(>102.5°"caliper deciduous trees. Per approved Tree Mitigation Plan 7 trees to be installed in front yard and side yard areas following construction. Do not plant these trees in the strut right of way area. Attachments: EAGAN FORESTRY DIVISION X Yes (Refer to attar haavniEtY k ':P, s) No BY Additional Notes: DATE `1 " H:\ghove`o016file\treepres\Tree Nreservat, n Han b'tone Von Lot i ocK I ) Surveyor's Certificate SURVEY FOR :Norton Homes DESCRIBED AS :Lot 1, Block 1, STONE RUN.City of Eagan, Dakota County. Minnesota and reserving easements of record. .\ \\\_. F ST .tlry4172 LECHASE:' / / , . 1 •_ 7,: \ ,• Doi cons�,71p ,rf r \\ ; �\ 10164 \ 1011.4 \\I;\,fir v \\ O7Q�Opl O i ��1, ®' IP A oast® 1 1 / .:. .y‘ ,,,,,,r ,.. > ..._,-,..* X Ill T.1019.0 ,1 `/ 06 \\ ` M. is, d,3 a (��%,37,er. •r� 1 tt 1 1 9) Ore* '.•,. 1 .-- ‘7411 �' .SET IP si, 1 ,AL 7 _\ . \•\\ \\\W I\. 102.9 ( \ ,.__ \. •� ; 1014 `•44\ I 1\ 11 4r ' \ p2 1 \ N• �1� .. 11 1,4teN i g g r 1 \ \\•I \` .9y `?\'. t`. 1020.32 f t1 F 000 , .� 45 :-•t r 11 1 m N is 1 `• ;a- .9 1 I •‘..7 �ce• ,\\ ` ..,:e,..11.v _;` ` \\1 Y _- 1 1 II g8 I Y I . . \•• \1 1 ' \i� 4l00 -1''N. ''.4°°t6'- i..>, 1 Exist 11om 1 1 i 1 O i Ii.-- q5)..-g6-, :- ,a I ••` -, ro I 1-V-1, - 1 ,r 5 I -_rers•_es'•w•®•a.•..e..e•a.oey` �\`\I I til p 1o9az' ---- \ II ", €••y..•!10!.1•;1 i+f_0.tiff+0.0.MBYfi ' Q1 tt i ;\ �S 1 1 M ---- ---s-- 1e ams's \ \ \\ 6 1 \1 11 II I 991}-- \\ 1 •i111 s i \ LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: + 11 Ake- i, Sin& R DATE OF SURVEY: iCt7////k LATEST REVISION: 12-/$/if✓ m m c Y a -0 11 WV& io 4 a...lei- hiis O z < DOCUMENT STANDARDS ❑ ❑ • Registered Land Surveyor signature and company o '2� if y -1?r✓IaL ` / ❑ ❑ • Building Permit Applicant A ❑ ❑ • Legal description 2--g-/b P, yn, ❑ ❑ • Address 7( ❑ ❑ • North arrow and scale / ❑ ❑ • House type(rambler,walkout,split w/o,split entry, lookout,etc.) PCI CI • Directional drainage arrows with slope/gradient% ❑ ❑ • Proposed/existing sewer and water services&invert elevation ❑ ❑ • Street name ❑ ❑ • Driveway(grade&width-in R/W and back of curb,22' max.) El ❑ • Lot Square Footage ,6 ❑ ❑ • Lot Coverage ELEVATIONS Existing I' ❑ ❑ • Property corners '' ❑ ❑ • Top of curb at the driveway and property line extensions /" ❑ ❑ • Elevations of any existing adjacent homes ,0' ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches yr ❑ ❑ • Waterways(pond,stream,etc.) ' Proposed for ❑ El • Garage floor 7 ❑ ❑ • Basement floor ❑ ❑ • Lowest exposed elevation(walkout/window) J' ❑ ❑ • Property corners 7 ❑ ❑ • Front and rear of home at the foundation YI • PRV Required PONDING AREA(if applicable) ,ef ❑ ❑ • Easement line ❑',' ❑ • NWL ❑ ,0" ❑ • HWL ❑ / ❑ • Pond#designation ❑ ,ki El • Emergency Overflow Elevation ❑ ❑ • Pond/Wetland buffer delineation Y g • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ❑ ❑ • Lot lines/Bearings&dimensions ,r/ i, ❑ / • Right-of-way and street width(to back of curb) e );t--0 1 • Proposed home dimensions including any proposed decks,overh_ an9s greater than 2',porches,etc. (i.e. all structures requiring permanent footings) „O' ❑ ❑ • Show all easements of record and any City utilities within those easements ,B ❑ ❑ • Setbacks of proposed structure and sideyard setback of adjacent existing structures .2 ❑ ❑ • Retaining wall requirements: Reviewed By:/1 '••- Date 12 e"ife G:/FORMS/Cert.of Survey Checklist Rev.3-3-11 lir Surveyor 's Certificate i SURVEY FOR : Norton Homes DESCRIBED AS : Lot 1, Block 1, STONE RUN, City of Eagan, Dakota County, Minnesota and reserving easements of record. 3:1 Maximum Slopes or Retaining WaN VIA\ Be Required 1 __41\ ' _ --- --- / 4 72 /� / ' \,- STEL/ LECHASE/ �\ \-.' 1 / �r +\� \\ I \\J \ Rock Const\ c / S7 \ Ent. \� / _.i `\ �\ J �c\ 1015.4 \ 1017.4 \\ / \ -.--8 / w - 1 _A(,./15<1 1.111Will'wiralrotiv ,8i `\ "64�Y r ~TIP -� IP _ �3 I ��ST \•Y/ • i1 ,+ 1 _ .II015.1i �L �S! 1 PE`-I1 ``_08 // ''���> ,� 1' 1�,\:---1:, 020.5 I \ __ °„) 101A leg \ : , * 1 B=1016.5 1 II \ , \ / `. 70 ''\ �� \1015. \ Q ss' 1.3 \\ 1 1 O1 I ^�� E) o• `�\ X� OO O x \ 1 1 \ 1 004. N7-411P- I�` hti ti 2• \ �•DO \ \ O \\ \ c'0, .8 \I I! . O r, S;T " . \10 'i7• • C D1,4-)`\\ ALAI 1020.9 \1S020 s /_____ \ -T \ 1 -\\ 30 /0',// \ �\ ;7:ii_11111: 1 \ "-� OOZ 1 \ I 1 11 1 ) \ I \ I\\ \\ z \ l + \\ �/- -\ �`v-1 I \ I \ • os �o • • 1 / �.' I\\I S\ u� ''� o\, 1\I 1-1020.0 \1 x h\ \\ •• °?00 00 �o x.00 1015 6 „\ I B=1017.0 I I \ I i \ y.\tea _�\ • BM:HUB r '1 j \\ � \\ :404:0,..":12;14.5 w� h 1020.32 �m3'. • / 11 11 1O0'{ ArsI \, 0008.0 h� o A1ir ,1!�.� 3~ / 1 7 o T1019.0 / I 11 \ \\ + OO o61\i • \I • 1 16.0 -/ _--1 1 Ia I \ fie \ a?�\\a0 ' \ 028.9 1 • I \\ y\\ c'e \ 00 ,,,� \ \ \\ \-_--, \ ,\ \ , - - \1' 11 11y ' �r\ `X04.6\+\� -1006. s - J\\ \1ti Exist Home 1 1 r- 11-4 . I \� -4. 4.'_'.1 6•.••o \00 ,, \.. + C 1015.2k 1 I p ��_ 107.0 ~10043\\ \ �\ �-i1 1 I 11 if --.\J��� I, _3 I �__ IC�r!!!.!.•.!• •!l.�1r! !►�� ` \�\ 1 1 OOI\ 1°14,\71"---r---- .1 O_1 v L'J 1 1 •!!•:ao••••••!l��l:!!•!�•....•el % * 41\ 1. \ \ \ \ .1 / •, 6.."0\ \ I\ �, \ Z .1E50 1\ 1 I1, I 99 \\ q ••r \{5 \rr-:O \\ I I ^\ N .1 I ----- ` N! !' e O I\ \ \ l 2 O I I' °�,- 1 I I - 988-------------\ \\ �•. • t O' `, \ \ `\ z t'" , I 1-----986- \ O. 3t \ V 1 -- , I I / / \ \•\ l� • '�. 1\ \ \• L w ' r r---984----, / / \ .\ • •!' I �- 10 / / . /+/ /1 /-982-% // �/ I L9� •\\\ \\\ O' =-•1 \`\\�. wa / A / / /Nati Elev =987/.2 / , / \ • !.I 1 ra, 1 /� / / / / / / / / \ \ \ • ! g 4 EI i^ g- 1 / I I /i [ / / / \ \• \ .• n i I / / , 4 1 MP O ------- ' U H25 110� - .i-' . 4 H ; ,� i/ 1� w w w w w i • .- i , / , i ,-� _-S FND IP 991.31 SET IP 991.2 137.91 N89'45'06"E 1000.4 4,�/ WED • J PAGAN ENG > ERING DEPT. LOT SQ. FOOTAGE = 29, 069 HOUSE SQ. FOOTAGE = 3, 882 PROPOSED ELEVATIONS HOUSE COVERAGE = 13. 3% Top of Foundation = 1017.0 Garage Floor = 1016.6 Basement Floor = 1008.3 Aprox. Sewer Service = Verify Proposed Elev. = MIN. SETBACK REQUIREMENTS Existing Elev. = Front - 30 House Side -10 Drainage Directions = Denotes Offset Stake = • SCALE: 1 inch = 30 feet Rear -15 Garage Side -5 I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTATION JOB NO: OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED SCSI LANDFORM BY ME OR UNDER MY DIRECT SUPERVISION AND DOES NOT PURPORT TO • • SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN. BOOK: PAGE: From Site to Finish • • 105 S. Fifth Ave. DATE _i / _/_16 , �• A.rt-D/ CAD FILE: Suite 513 �� Y D. LINDGREN, �D SURVEYOR Minneapolis, MN 55401 k Stone Run Phone: (612) 252-9070 MINNESOTA LICENSE NUMBER 14376 PERMIT City of Eagan Permit Type:Building Permit Number:EA141970 Date Issued:04/10/2017 Permit Category:ePermit Site Address: 4872 Steeplechase Way Lot:1 Block: 1 Addition: Stone Run PID:10-72580-01-010 Use: Description: Sub Type:Fireplace Work Type:Gas Fireplace (new) Description: Census Code:434 - Zoning: Square Feet:0 Occupancy: Construction Type: Comments:Improvements to the home may require smoke detectors in all bedrooms. Chimney / flue must be inspected prior to concealing. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Valuation: 3,000.00 Fee Summary:BL - Base Fee $3K $88.50 0801.4085 Surcharge - Based on Valuation $3K $1.50 9001.2195 $90.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Bhavana Anand 4872 Steeplechase Way Eagan MN 55122 Fireside Hearth & Home 2700 Fairview Ave N Roseville MN 55113 (952) 985-6675 Applicant/Permitee: Signature Issued By: Signature PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA144587 Date Issued:08/01/2017 Permit Category:ePermit Site Address: 4872 Steeplechase Way Lot:1 Block: 1 Addition: Stone Run PID:10-72580-01-010 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Heater & Water Softener Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener). Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Bhavana Anand 4872 Steeplechase Way Eagan MN 55122 Water Doctors Water Treatment Company 8201 Old Central Ave, Suite F & G Spring Lake Park MN 55432 (763) 535-1800 Applicant/Permitee: Signature Issued By: Signature 11 DEPARTMENT OF RECEIVED 111 LABOR AND INDUSTRY AUG U 9 201 8/9/2017 APPROVED FOR USE Bhavana Anand 4872 Steeplechase Way EAGAN,MN 55122 RE: PERMIT#ELV1704-00120 Project: BHAVANA ANAND Location: EAGAN,MN 55122 \f � c-ft7 Fe LECHASE WAY \\/ Dear Sir or Madam: Minnesota Statutes Chapter 326B provides that the Department of Labor and Industry,Construction Codes& Licensing Unit, Elevator Safety Section, inspect and approve elevators and manlifts(endless belt lifts)before they can be legally used in Minnesota. An Inspector from the Elevator Safety Section recently inspected your facility and determined it meets requirements of the Minnesota Elevator Safety Code. NOTE: Compliance with Minnesota Rules and the ANSI/ASME A17.1,Safety Code for Elevators and Escalators does not necessarily assure compliance with the Americans With Disabilities Act of 1990. Sincerely, Gary Bjorklund Elevator Code Rep Construction Codes and Licensing\Elevator Inspections CC:ARROW LIFT ACCESSIBILITY Dale Schoeppner,City of Eagan Building Official ElFormCE2R 443 Lafayette Road N.,St.Paul,MN 55155• (651)284-5005• www.dli.mn.gov An Equal Opportunity Employer DEPARTMENT OF IIILABOR AND INDUSTRY RECEIVED AUG 0 91011 CERTIFICATE OF APPROVAL PERMIT TYPE; ELV INSTALL SITE: BHAVANA ANAND Address: 4872 STEEPLECHASE WAY City: EAGAN,MN Approval is for permit work performed by ARROW LIFT ACCESSIBILITY under permit number ELV1704-00120, and based upon the requirements set forth in the Minnesota Statutes,Chapter 3268.184 and Minnesota Rule 1307.0035. If you have questions related to the issuance of this permit call: (651)284 5071 Department of Labor and Industry Construction Codes and Licensing I Elevator Inspections 443 Lafayette Road N.,St. Paul, MN 55155 • (651)284-5005 • www.dli.mn.gov An Equal Opportunity Employer Use BLUE or BLACK Ink r For Office Us q-ty 6-s- _L Cityof Eakall Permit#:Permit Fee: 60 Or, �. 3830 Pilot Knob Road Eagan MN 55122 Phone: (651)675-5675 Date Received: Fax: (651)675-5694 PO/ /4(8� Staff: � 2017 ERMIT APPLICATION ❑ Please submit two (2)sets of plans with all commercial applications. Date: y, \I-7 \ )1 Site Address: L 'W )L S1 4,6-41.f,„l''''C ''- )))))) Tenant: Suite#: Resident/Owner Name: Phone: ! Address/City/Zip: . -,,. Name: o�l ,{�. ,� - _ ._�a..,.M� ._,,_ �.a License#: ���TC�i�1 ..� %\\ LU \, Address: � � City: ���C`�Il�. Cgrltt e�CtO� e r ��Z" 2 7-- - s State:}'Y1W Zip:, � �� Phone: W ,i Contact ,C\1Tr% 5)r42— Email: t,r [ , .0.._ J--r..0- 1 ur("`�-t New Replacement Additio al Alteration Demolition Type.of Work .. Description of work: b r., ��-r'S � i„ I NOTE: Roof mounted and ground mounted mechanical equipment is required to be screened by City 4 Code. Please.contact the Mechanical Inspector for fnforraation on permitted screening methods. p RESIDENTIAL COMMERCIAL Furnace New Construction Interior Improvement Air Conditioner Install Piping Processed Permit Type — 1 —Air Exchanger Gas Exterior HVAC Unit i _Heat Pump —Under/Above ground Tank ( Install/_Remove) t Other RESIDENTIAL FEES $60.00 Minimum Add or alteration to an existing unit, includes State Surcharge $100.00 Residential New, includes State Surcharge =$ TOTAL FEE I COMMERCIAL FEESContract Value$ x.01 $60.00 Permit Fee Minimum $75.00 Underground tank installation/removal, includes State Surcharge =$ Permit Fee _$ Surcharge Surcharge=Contract Value x$0.0005 If the project valuation is over$1 million, please call for Surcharge =$ TOTAL FEE I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit,but only an application for a permit,and work is t to start without a permit;that the work will be in accordance Mth the approved plan in the case 42 W ccase of work which requires a review and approval of plans. K \)t_(l.yn ilIIx _ - Applicant's Printe� Name Applicant's i atu FOR OFFICE USE Required Inspections: Reviewed By: Date: Underground Rough In Air Test Gas Service Test In-floor Heat Final HVAC Screening I*P City of Eaall Address: 4872 Steeplechase Way Permit#: 140484 The following items were /were not completed at the Final Inspection on: 0 ' 2,, 1 7 Complete Incomplete pomments Final grade - 6" from siding Permanent steps — Garage Permanent steps— Main Entry Permanent Driveway t/. Permanent Gas Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn Trail / Curb Damage Porch Lower Level Finish Deck ✓� Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: 1 (Y) ,.`< 1 1 G:\Building Inspections\FORMS\Checklists ; For Office Use/C3'1 , IJ 94,1 ::::e: ... .r"' �► lf/ 4 17 Date Received: 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD:(651)454-8535 I FAX:(651)675-5694 Staff: buildinginspections(@citvofeagan.com 2019 RESIDENTIAL PLUMBING PERMIT APPLICATION Date: / 1 ' \ Site Address: L ' \tJ Tenant: Suite#: t p Name: Phone: Address/City/Zip: Rt q e,4Name: Las N. ��GLicense#:PC13 7 33 .3 Address: C‘S4LWCit • AVV)•OV6' `'" x State: MN Zip: SS3ct1 Phone: 6:5 LiL7" 7 ,sz.6 �. Contact: 1.,__JAitt„,. Email: I - -�� W ri l. .. = New Replacement Repair Rebuild Modify Space Work in R.O.W. Description of work: Tankless Water Heater Lawn Irrigation( RPZ/ PVB) , Standard Water Heater • Add Plumbing Fixtures( Main/ Lower Level) � Water Softener Boo(..)sizr6 p Description: Purl? r ; g Septic System Wu, New Abandonment Connection to City Water from Well RESIDENTIAL FEES $60.00 Water Heater, Water Softener, or Water Heater and Softener(includes State Surcharge) $60.00 Lawn Irrigation (includes State Surcharge) $60.00 New fixtures, adding or removing piping (includes State Surcharge) I $60.00 Septic System Abandonment $100.00 New Residential (fee collected with Building Permit) $115.00 New Septic System (includes County fee and State Surcharge) $60.00 Connecting to City Water from Well* + $290 for Meter and $190 for Radio Read = $540 *Sewer&Water Permit also required for connection charges TOTAL FEES $ (DC) CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www cp_pherstateornecall.o g You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.cityofeagan.com/subscribe. I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the rdinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start ,, o a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of .pans . xLkAK6 x //f Applicant's Printed Name A l cant's ' g ure Page 1 of 2