Loading...
1272 Interlachen Dr 6 L ///6 oh 00 . D /G// � CS � Use BLUE or BLACK Ink (J ��Q For Office Use I .- �� Permit#: / 1/C >J � .274 Cityof Eag,all /4E 7y �, o Permit Feer _ v 3830 Pilot Knob Road // - / Eagan MN 55122 RECi�IV�� Date Received: �l'FJ ` !I Phone:(651)675-5675 Fax:(651)675-5694 MAR 16 2017 Staff: I NI y J 2017 RESIDENTIAL BUILDING PERMIT APPLICATION � I� n "c Date: 3/ISite Address: ,G 1 2- l i\= n d�G , `°unit#: D.R. Horton, Inc Name: Phone: ICsider Address/city/zip: 20860 Kenbridge Court Suite 100, Lakeville, MN 55044 Applicant is: Owner X Contractor 20-//e,2 /' / £/ i'O/i4. k- Description of work: New Residential, Single Family 6 ' '-- Ty e of Work o0 e;t Construction Cost: % � -L L.. Multi-Family Building:(Yes /No X ) Company: D.R. Horton, Inc contact: Brooke Hareid ,po: 20860 a Kenbridg Court Lakeville ;- Address: City: Contractor State: MN Zip: 55044 Phone: 952-985-7806 Email: bmhareid@drhorton.com License#: BC605657 Lead Certificate#: if the project is exempt from lead certification, please explain why: New Construction COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit(for a similar plan based on a master plan? /Yes No If yes,date and address of master plan:�i(►2.11(0 ' `w Grade- G1crve.., Licensed Plumber: Sabre Plumbing & Heating Phone: 763-473-2267 Mechanical Contractor: Sabre Plumbing & Heating Phone: 763-473-2267 Sewer&water Contractor: Starr Plumbing Phone: 952-884-4149 Fire Suppression Contractor: Phone: NOTE Plans and supporting documents that you submit are 4Onsidered to be pubic information Portions of the information may be classified as nonp tublic if you provide specific reasons that would perit itie City to F4 conclude that they tCs9de'Se+CfetS CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. y atevi - Applicant's Pri ted Name Applicant's a nature Page 1 of 3 0 � , j", 7, . J.---04 /6/-- )f ' DO NOT WRITE BELOW THIS LINE /(./74' - SUB TYPES _ Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration(Multi) Multi _ Deck Porch(Screen/Gazebo/Pergola) Miscellaneous 01 of_Plex Lower Level Pool Accessory Building WORK TYPES New Interior Improvement Siding _ Demolish Building* Addition _ Move Building _ Reroof _ Demolish Interior Alteration — Fire Repair _ Windows _ Demolish Foundation Replace Repair Egress Window Water Damage Retaining Wall *Demolition of entire building—give PCA handout to applicant DESCRIPTION Valuation .j 7.4(0 (t 1 Occupancy .t 1,-- MCES System Plan Review Code Edition O1vi,„/ 01s SAC Units (25%o N 100% ) Zoning ft) City Water Census Code Stories A Booster Pump #of Units Square Feet ' , '4 PRV #of Buildings Length Fire Suppression Required Type of Construction Yrs,,, Width 4/6,) REQUIRED INSPECTIONS CC�� I1 Footings(New Building) Meter Size: Footings(Deck) X Final I C.O. Required Footings(Addition) Final I No C.O. Required X Foundation X" Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test .IK Roof:_Ice&Water Final Pool: Footings Air/Gas Tests Final Framing 30 Minutes 1C 1 Hour Drain Tile --. Fireplace: K Rough In k Air Test 'Final Siding:_Stucco Lath A. Stone Lath Brick EFIS Insulation Windows Sheathing Retaining Wall: Footings_Backfill_Final Sheetrock X Radon Control Fire Walls Fire Suppression: Rough In_Final iik, Braced Walls X Erosion Control Shower Pan Other: 2,...,, Reviewed By: , Building Inspector RESIDENTIAL FEES 60 eiiG h hA/ '7Zr v6 - // 4 ,$-z2 Base Fee Surcharge Ii ` �� Plan Review ; -415 L. t "` �/ ccorieMor MCES SACI it; f 09 City SAC a Utility Connection Charge ' ,2r' `' f r ' 3 ./Lt"/ S&W Permit&Surcharge if ,' ' P ^",% C� (ir��r` 2-3 Treatment Plant , { , /� / Copies ' ., S 570 V TOTAL ir & ((ill/Z(41 J Pa62op3 d New Construction Energy Code Compliance Certificate N` ' ° Date Certificate Posted k* { e Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel. 3/15/17 f l�/(G+/ -5 3 Mailing Address or the Dwelling or Dwelling Unit 1272 Interlachen Drive Name of Residential Contractor MN License Number DRHorton BC605657 Community Plan ID Eagan 5435 THERMAL ENVELOPE RADON SYSTEM o Type:Check All That Apply x Passive(No Fan) ^' Active(With fan and monometer or o d, other system monitoring device) o a 3 + Lj = o N a U Location(or future Location)of Fan: U Insulation Location o Z a v w p o O • ro o b v H 4 Z w w w° w° u rx Other Please Describe Here Below Entire Slab X f Foundation Wall(Sides) R-15 X R-10 Exterior,R-5 Interior Foundation Wall(Front and Back) R-10 X Exterior Rim Joist(Foundation) R-20 X Interior Rim Joist(Irt Floor+) R-20 X Interior 1 Wall R-21 X Ceiling,flat R-49 X Ceiling,vaulted R-49 X Bay Windows or cantilevered areas R-30 X Bonus room over garage R-32 X X Describe other insulated areas Building Envelope air Tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: 0.31 Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 0.31 R-8 R-value MECHANICAL SYSTEMS ( Make-up Air Select aType Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code Fuel Type NAT GAS NAT GAS R-410A Passive Manufacturer Bryant Rheem Bryant Powered Interlocked with exhaust device. Model 912SC48080S17 PROG5042NRH67PV BA13NA030 Describe: Input in 80000 Capacity in 50 Output in 2.5 Other,describe: Rating or Size BTUS: Gallons: Tons: AFUE or 92% SEER or 13 I..ocation of duct or system: Efficiency HSPF"/o ' EER HEAT LOSS HEAT GAIN COOLING LOAD RESIDENTIAL LOAD CALC 56,821 22,460 28,895 Cfm's l "round duct VR Mechanical Ventilation System "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace Not required per mech.code Select Type X Passive Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: X Energy Recover Ventilator(ERV)Capacity in cfms: Low: 40%=124 High: 70%=217 Location of duct or system: Balanced Ventilation Capcity in CFMS: furnace room ILocations of Fans,describe: Cfm's Capacity continuous ventilation rate in cfms: 90 4 "round duct OR Total ventilation(intermittent+continuous)rate in cfms: 180 "metal duct 1272 Interlachen Drive Eagan HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing&Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Wednesday, March 15,2017 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. t� b Resp f +al&Light„Gvm� � 0 meads ry, -P111,1:0**, Dev I j 0#011*6iveO Plistiti t155447r;,.,r„;49 '”" r i „j,y,;.,,, , t Project Report Project Title: 1272 Interlachen Drive Eagan Designed By: Michael Hoium Project Date: Wednesday, March 15, 2017 Client Name: DR Horton Client City: Lakeville, MN Company Name: Sabre Plumbing &Heating Company Representative: Michael Hoium Company Address: 15535 Medina Road Company City: Plymouth, MN 55447 Company Phone: 763-473-2267 Company Fax: 763-473-8565 Reference City: Minneapolis, Minnesota Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 n/a 30% 72 29.40 Summer: 88 73 50% 50% 75 35 Total Building Supply CFM: 1,003 CFM Per Square ft.: 0.240 Square ft. of Room Area: 4,177 Square ft. Per Ton: 1,735 Volume(ft3): 31,883 Total Heating Required Including Ventilation Air: 56,821 Btuh 56.821 MBH Total Sensible Gain: 22,460 Btuh 78 Total Latent Gain: 6,436 Btuh 22 Total Cooling Required Including Ventilation Air: 28,895 Btuh 2.41 Tons(Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Wednesday, March 15, 2017, 12:50 PM i� c kst p a1& J ht Con ai VVC oad „ ` ' �� , T�t4 re �+ tin1nr,, 8a idWlltt &I 4C1 i y. � ''''',4'#'44f"'. ��` Ca, �teri 4#a6 l PIymQuth,MI .;,55S7 '4 .. ' \. i/ \ ?age 3 Load Preview Report l Net ft.2 Sen Lat Net Sen HtgSys Cls Sys Act Duct Scope 6 TonII /Ton Area Gain Gain Gain Loss Size 9 d CFM CFM J CFM Building 2.41 1,735 4,177 22,460 6,436 28,895 56,821 666 1,003 1,003 System 1 2.41 1,735 4,177 22,460 6,436 28,895 56,821 666 1,003 1,003 12x15 Ventilation 999 4,177 5,175 6,685 Supply Duct Latent 109 109 Return Duct 55 49 103 366 Humidification 6,318 Zone 1 4,177 21,406 2,101 23,507 43,452 666 1,003 1,003 12x15 1-Basement 1,333 2,650 0 2,650 13,735 211 124 124 2-5 2-Main Floor 1,333 11,108 2,101 13,209 14,567 223 520 520 5-6 3-Second Floor 1,511 7,648 0 7,648 15,149 232 358 358 4-6 Wednesday, March 15, 2017, 12:50 PM RhvaC Residential&Light C Si aat` 1A toadsInterlaehen€tilve Plumbs g&Heating; N� X72 t=ag 1 Total Building Summary Loads Co'n h Ct £:., <. ® �f x 2s n z Y ✓ en � DRH LowEE 3131: Glazing-DRH Windows, u-value 0.31, 295 7,960 0 4,939 4,939 SHGC 0.31 DRH LowEE 3132: Glazing-DRH Windows/Glass Doors, 84 2,266 0 882 882 u-value 0.31, SHGC 0.32 DRH Door 31 UF: Door-DRH Exterior Door- .31 U Factor, 37.8 1,018 0 281 281 .23 SHGC DRH-R15 8ft-4in: Wall-Basement, Custom, DRH-8" 483.3 2,138 0 128 128 poured concrete wall, R-15 board insulation to footing, no interior finish, 8'-4"floor depth DRH-R15 4ft-4in: Wall-Basement, Custom, DRH-8" 104 384 0 4 4 poured concrete wall, R-15 board insulation to footing, no interior finish, 4'-4"floor depth 12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 3086.9 17,455 0 2,668 2,668 cavity, no board insulation, siding finish,wood studs DRH-R10 8ft-4in: Wall-Basement, Custom, DRH-8" 391.7 1,863 0 103 103 poured concrete wall, R-10 board insulation to footing, no interior finish, 8'-4"floor depth RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 472.9 2,060 0 578 578 Closed Cell Spray Foam R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 1511 3,024 0 1,668 1,668 Attic Floor(also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1333 3,131 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20'wide P-32 R-32: Floor-Over open crawl space or garage, 220 574 0 53 53 Custom, R-30 Blanket insulation, 3/4" Foamboard R- 2, any cover Subtotals for structure: 41,873 0 11,304 11,304 People: 6 1,200 1,380 2,580 Equipment: 901 4,116 5,017 Lighting: 1250 4,263 4,263 Ductwork: 1,945 158 398 556 Infiltration:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 180, Summer CFM: 180 6,685 4,177 999 5,175 Humidification (Winter)17.23 gal/day : 6,318 0 0 0 Total Building Load Totals: 56,821 6,436 22,460 28,895 Total Building Supply CFM: 1,003 CFM Per Square ft.: 0.240 Square ft. of Room Area: 4,177 Square ft. Per Ton: 1,735 Volume(ft3): 31,883 Building Total Heating Required Including Ventilation Air: 56,821 Btuh 56.821 MBH Total Sensible Gain: 22,460 Btuh 78 % Total Latent Gain: 6,436 Btuh 22 % Total Cooling Required Including Ventilation Air: 28,895 Btuh 2.41 Tons(Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Wednesday, March 15, 2017, 12:50 PM cry Res Ole,-, gal&Light CO17rii+eiat HVAC Loa0s r :.. * y4gP,*S2afinis b044.�t, t 5 S �� bn &Heattf e 4 *; 17Jnterlacie 1Vd , Plymouth,MN-55447". y , fi _ -pa9e Detailed Room Loads - Room I Basement (Average Load Procedure) Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 26.7 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 1,333.0 sq.ft. Supply Air: 124 CFM Ceiling Height: 8.3 ft. Supply Air Changes: 0.7 AC/hr Volume: 11,108 cu.ft. Req. Vent. CIg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 57 CFM Runout Air: 62 CFM Percent of Supply.: 46 Runout Duct Size: 5 in. Actual Summer Vent.: 22 CFM Runout Air Velocity: 455 ft./min. Percent of Supply: 18 Runout Air Velocity: 455 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.167 in.wg./100 ft. Actual Summer Infil.: 0 CFM E-Wall-DRH-R15 8ft-4in 29 X 8.3 241.7 0.042 4.4 1,069 0.3 0 64 E -Wall-DRH-R15 4ft-4in 12 X 4.3 52 0.041 3.7 192 0.0 0 2 E-Wall-12F-Osw 12 X 4 48 0.065 5.7 271 0.9 0 41 N -Wall-12F-Osw 47 X 8.3 306.7 0.065 5.7 1,734 0.9 0 265 W-Wall-12F-Osw 12 X 4 48 0.065 5.7 271 0.9 0 41 W-Wall-DRH-R15 4ft-4in 12 X 4.3 52 0.041 3.7 192 0.0 0 2 W-Wall-DRH-R15 8ft-4in 29 X 8.3 241.7 0.042 4.4 1,069 0.3 0 64 S -Wall-DRH- R10 8ft-4in 47 X 8.3 391.7 0.050 4.8 1,863 0.3 0 103 E -Wall-RJ 20 Spray Foam 41 X 1.5 61.5 0.050 4.4 268 1.2 0 75 N -Wall-RJ 20 Spray Foam 47 X 1.5 70.5 0.050 4.4 307 1.2 0 86 W-Wall-RJ 20 Spray Foam 41 X 61.5 0.050 4.4 268 1.2 0 75 1.5 S-Wall-RJ 20 Spray Foam 47 X 1.5 70.5 0.050 4.4 307 1.2 0 86 N-Gls-DRH LowEE 3131 shgc-0.31 45 0.310 27.0 1,215 9.9 0 447 100%S(3) N -Gls-DRH LowEE 3132 shgc-0.32 40 0.310 27.0 1,079 10.1 0 404 100%S Floor-21A-20 50 X 26.7 1333 0.027 2.3 3,131 0.0 0 0 Subtotals for Structure: 13,236 0 1,755 Infil.: Win.: 0.0, Sum.: 0.0 1,215 0.000 0 0.000 0 0 Ductwork: 499 43 Lighting: 250 853.... Room Totals: 13,735 0 2,650 Wednesday, March 15, 2017, 12:50 PM Rhvac Residential&:Light Commercial VA( i �t`tite SOkware 8 .4 abre�Plumbirg&Heatini i 'G; 272 lntcW�„ti t&ve Eacan �__ � Fl�! erutb,iVl(>[ X5447,; ,,; / %,,,,�.i,,.,,.., . ��4441.,,. .. 24, � M ,,--- ,- j n:i.--rOfitj Detailed Room Loads - Room 2 - Main Floor (Average Load Procedure) Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 26.7 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 1,333.0 sq.ft. Supply Air: 520 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 11,997 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 60 CFM Runout Air: 104 CFM Percent of Supply.: 12 % Runout Duct Size: 6 in. Actual Summer Vent.: 93 CFM Runout Air Velocity: 530 ft./min. Percent of Supply: 18 % Runout Air Velocity: 530 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.175 in.wg./100 ft. Actual Summer Infil.: 0 CFM of E3 9 L / f Y. \i is§r V 611 O $ E -Wall-12F-Osw 41 X 9 361 0.065 5.7 2,041 0.9 0 312 N -Wall-12F-Osw 47 X 9 327 0.065 5.7 1,849 0.9 0 283 W-Wall-12F-Osw 41 X 9 351 0.065 5.7 1,985 0.9 0 303 S -Wall-12F-Osw 47 X 9 349.2 0.065 5.7 1,975 0.9 0 302 E-Wall-RJ 20 Spray Foam 42.5 X 49.6 0.050 4.4 216 1.2 0 61 1.2 N-Wall-RJ 20 Spray Foam 47 X 1.2 54.8 0.050 4.4 239 1.2 0 67 W-Wall-RJ 20 Spray Foam 42.5 X 49.6 0.050 4.4 216 1.2 0 61 1.2 S -Wall-RJ 20 Spray Foam 47 X 1.2 54.8 0.050 4.4 239 1.2 0 67 S -Door-DRH Door 31UF 3 X 6.7 20 0.310 27.0 539 7.4 0 149 S -Door-DRH Door 31UF 2.7 X 6.7 17.8 0.310 27.0 479 7.4 0 132 E-Gls-DRH LowEE 3131 shgc-0.31 8 0.310 27.0 216 33.0 0 264 0%S N -Gls-DRH LowEE 3131 shgc-0.31 8 0.310 27.0 216 9.9 0 79 100%S N -Gls-DRH LowEE 3131 shgc-0.31 12 0.310 27.0 324 9.9 0 119 100%S N-Gls-DRH LowEE 3131 shgc-0.31 36 0.310 27.0 970 9.9 0 356 100%S(2) N -Gls-DRH LowEE 3132 shgc-0.32 40 0.310 27.0 1,079 10.1 0 404 100%S W-Gls-DRH LowEE 3131 shgc- 18 0.310 27.0 485 33.0 0 594 0.31 0%S S-Gls-DRH LowEE 3131 shgc-0.31 36 0.310 27.0 970 18.2 0 654 0%S (2) Subtotals for Structure: 14,038 0 4,207 Infil.: Win.: 0.0, Sum.: 0.0 1,793 0.000 0 0.000 0 0 Ductwork: 529 178 People: 200 lat/per, 230 sen/per: 6 1,200 1,380 Equipment: 901 3,638 Lighting: 500 1.,705..... Room Totals: 14,567 2,101 11,108 Wednesday, March 15, 2017, 12:50 PM a"wi � i aha Rhvec Re�dsnti�� ��`fi��rnr�er+��ai HVAC�+� � ,, , ��, *,fiA0.*Hare pevitrijr4,fnc e ins r , Ownfl60 r PIy uth,MN 55447"" *..:' €:, ... 4§4tiii,,, .. ll' graf ice.. , .. ,z"Page 7, Detailed Room Loads - Room 3-Second Floor (Average Load Procedure) G eri" i ,M4A .�,.., y.: , i �a . tti'!; i ce ;. . `�: �.,..,,,,.. . . _ Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 30.2 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 1,511.0 sq.ft. Supply Air: 358 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.8 AC/hr Volume: 12,088 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 63 CFM Runout Air: 90 CFM Percent of Supply.: 18 % Runout Duct Size: 6 in. Actual Summer Vent.: 64 CFM Runout Air Velocity: 456 ft./min. Percent of Supply: 18 Runout Air Velocity: 456 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.130 in.wg./100 ft. Actual Summer Infil.: 0 CFM x E -Wall-12F-Osw 42.5 X 8 328 0.065 5.7 1,855 0.9 0 284 N -Wall-12F-Osw 47 X 8 331 0.065 5.7 1,872 0.9 0 286 W-Wall-12F-Osw 42.5 X 8 325 0.065 5.7 1,838 0.9 0 281 S -Wall-12F-Osw 47 X 8 312 0.065 5.7 1,764 0.9 0 270 E -Gls-DRH LowEE 3131 shgc-0.31 12 0.310 27.0 324 33.0 0 396 0%S N -Gls-DRH LowEE 3131 shgc-0.31 45 0.310 27.0 1,215 9.9 0 447 100%S(3) W-Gls-DRH LowEE 3131 shgc- 15 0.310 27.0 405 33.0 0 495 0.31 0%S S-Gls-DRH LowEE 3131 shgc-0.31 60 0.310 27.0 1,620 18.1 0 1,088 0%S (4) S-Gls-DRH LowEE 3132 shgc-0.32 4 0.310 27.0 108 18.5 0 74 0%S UP-Ceil-R49 16B-49 30.2 X 50 1511 0.023 2.0 3,024 1.1 0 1,668 Floor-P-32 R-32 10 X 22 220 0.030 2.6 574 0.2 0 53 Subtotals for Structure: 14,599 0 5,342 Infil.: Win.: 0.0, Sum.: 0.0 1,432 0.000 0 0.000 0 0 Ductwork: 550 123 Equipment: 0 478 Lighting: 500 1,705.... Room Totals: 15,149 0 7,648 Wednesday, March 15, 2017, 12:50 PM Site address 1272 Interlachen Drive, Eagan MN Date 3/15/2017 Contractor Sabre Plumbing & Heating Completed Michael H Section A Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation 11-1) Square feet(Conditioned area including 4177 Total required ventilation 180 Basement—finished or unfinished) - Continuous ventilation 5 O Number of bedrooms t� Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1. The table and equation are below Table R403.5.2 Total and Continuous Ventilation Rates(in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/ sa.ft.l continuous ion in io is Contin io is on in�o is on inuouc continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 •-: 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 1•i * 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake,or both,for defrost or other equipment cycling. Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided, on a continuous rate average for each one-hour period.The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. Section B Ventilation Method (Choose either balanced or exhaust only) Balanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recovery Exhaust only Ventilator)—cfm of unit in low must not exceed continuous Continuous fan rating in cfm ventilation rating by more than 100%. Low cfm: '124 High cfm: n Continuous fan rating in cfm(capacity must not exceed L continuous ventilation rating by more than 100%) Directions-Choose the method of ventilation,balanced or exhaust only.Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts.Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Schedule Description Location Continuous Intermittent Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it is used for continuous or intermittent ventilation.The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls (Describe operation and control of the continuous and intermittent ventilation) ERV has wall control-set to 40%=124 CFM ERV has wall control-set to 70%=217 CFM Directions-Describe the operation of the ventilation system.There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance.Related trades also need adequate detail for placement of controls and proper operation of the building ventilation.If exhaust fans are used for building ventilation,describe the operation and location of any controls,indicators and legends.If an ERV or HRV is to be installed,describe how it will be installed.If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures' installation instructions.If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation,such interconnection shall be made and described. Directions-In order to determine the makeup air,Table 501.4.1 must be filled out(see below).For most new installations,column A will be appropriate,however,if atmospherically vented appliances or solid fuel appliances are installed,use the appropriate column. Please note,if the makeup air quantity is negative,no additional makeup air will be required for ventilation,if the value is positive refer to Table 501.4.2 and size the opening.Transfer the cfm,size of opening and type(round,rectangular,flex or rigid)to the last line of section D. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical- vent or direct vent ap-pliances assisted appliances and power gas or oil appliance or one solid ly vented gas or oil appliances or no combus-tion appliances vent or direct vent appliances fuel appliance or solid fuel appliances Column D Column A Column B Column C 1. 0.15 0.09 0.06 0.03 a)pressure factor (cfm/sf) b)conditioned floor area(sf)(including unfinished basements) 4177 Estimated House Infiltration(cfm):[la 627 x ib] 2.Exhaust Capacity a)continuous exhaust-only ventilation system ERV=0 (cfm);(not applicable to ba-lanced ventilation systems such as HRV) b)clothes dryer(cfm) 135 135 135 135 c)80%of largest exhaust rating(cfm); Kitchen hood typically 240 (not applicable if recirculating system or if powered makeup air is electrically interlocked d)80%of next largest exhaust rating Not (cfm);bath fan typically Applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked Total Exhaust Capacity(cfm); 375 [2a+lb+2c+2d] 3.Makeup Air Quantity(cfm) 375 a)total exhaust capacity(from above) b)estimated house infiltration(from 27 above) 6 V Makeup Air Quantity(cfm); [3a-3b] 2/�/1 (if value is negative,no makeup air is needed) -252 L�Y,1J L 4.For makeup Air Opening Sizing,refer NOT REQ'D to Table 501.4.2 A.Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent appliances may be used.) B.Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may also be included.) C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fule appliances. • Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units One or multiple power One or multiple fan- One atmospherically vented Multiple atmospherically Duct di- vent,direct vent ap- assisted appliances and gas or oil ap- vented gas or oil ap- ameter pliances,or no combus- power vent or direct vent pliance or one solid fuel pliances or solid fuel tion appliances appliances Column B appliance appliances Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening 318-419 196-258 136-179 84-110 9 w/motorized damper Passive opening 420-539 259-332 180-230 111-142 10 w/motorized damper Passive opening 540-679 333-419 231-290 143-179 11 w/motorized damper Powered makeup air >679 >419 >290 >179 NA Notes: A.An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. B.If flexible duct is used,increase the duct diameter by one inch.Flexible duct shall be stretched with minimal sags.Compressed duct shall not be accepted. C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D.Powered makeup air shall be electrically interlocked with the largest exhaust system. Combustion air Not required per mechanical code(No atmospheric or power vented appliances) Passive(see IFGC Appendix E,Worksheet E-1) Size and type 3"Rigid,4"Flex Other,describe: Explanation-If no atmospheric or power vented appliances are installed,check the appropriate box,not required.If a power vented or atmospherically vented appliance installed,use IFGC Appendix E,Worksheet E-1(see below).Please enter size and type.Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace,Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance information. Furnace/Boiler: 80000 raft Hood Dan Assisted C)irect Vent Input: Btu/hr or Power Vent Water Heater: 40000 raft Hood Z Fan Assisted ❑Direct Vent Input: Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. 2016 The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 LxWxH 14 LnWnH Step 3:Determine Air Changes per Hour(ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) 4a.Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft3 Volume(TRV) If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed. If CAS Volume(from Step 2)i s less than TRV then go to STEP 5. 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: 40000 Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3000 ft3 Required Volume Fan Assisted(RVFA) Total Btu/hr input of all Natural draft appliances Input: 0 Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: 0 ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= 3000 + 0 = 3000 TRV ft3 Step 5:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio= 2016 / 3000 = 0.67 Step 6:Calculate Reduction Factor(RF). RF=lminus Ratio RF=1- 0.67 = 0.33 Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000 Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area(CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA= 40000 /3000 Btu/hr per ina= 13.33 in2 Step 8:Calculate Minimum CAOA. .1 Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 1 3.33x 0.33 = 4.37 in2 Step 9:Calculate Combustion Air Opening Diameter(CAOD) CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 2.36 in.diameter go up one inch in size if using flex duct 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. e IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method(cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 ,1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 _5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1.The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2.This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. / 7// ;: 6 City of Ea aIl City Inspection Dept. Copy 400' J City Forester Copy Applicant/Builder Copy '74AititvOyAt,ftesib#MIAL 7"-7-T }may■ TRE w: ES V TI rd N SUM , (BUILDER, PLEASE READ ATTACHMENTS) Development Dakota Path 5th Addition Lot Number 10 Block Number 1 Address 1272 Interlachen Drive Builder D. R. Horton Phone Number: 612-508-1642 Contact: Kevin Bartol Tree Protection Requirements: Tree Protection Fencing Installed on Site(Erosion tubes) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: Not Required X As Follows: Two(2)Category B trees(>=2.5"caliper deciduous trees or>= 6' hgt coniferous trees), per approved Tree Mitigation Plan; one in front yard, one in back yard.To be installed following completion of construction. Attachments: EAGAN FORESTRY DIVISION X Yes (Refer to a aEifEVI►Lf�►vVE tails) No BY Additional Notes: DATE 3 -4= I H:\ghove\2017file\treepres\Tree Preservation Plan Dakota Path 5"'Add. .ot 12 Block 1 w o 0 0 v o � N 3 a i.1d m m N�Ai g m g��� B cm gi G 'a �'aE W .1121A.14 rnR Pill a [I 'E-\, ,i,1 ''i hec......1 g I 111F. 1 AR _s H 1 ,s -s1 t\ 10& , '. O — N00°12 53"E 125.44 — 1 44.,1 -- io30..9 W / - 0' • -10 8 ' '11 :5 N 1026.0;., \ i I. LI 101r I ;=•6.5oi5.50- I 10 -�30-r- /1038.9 ° -rl 8 �' 41 0., I L, � r— > co y' PROPS p,\w— z ! 6.83 7: '4. g "1-121:-uj\\-.'1\\*,:-\"\-\e'''4''4:1! : D il,L i II 0-7 ,,---i--1 1 Lt1 ,.;,A, _r.) ?La N Ol.`',A1\ Y•\.."4,. ,..t4 I Sy I A N O I 10..371, 23.5 - �+' `� or. ii I ' 10 I ->.12.50•i 2.50-e.:I _ �o{• - G1 1038.7)1' ''.1-10300.7 -- a _ • - T.B.33.45 ":— 4.00 -- 1038.4 0 0— / N00°12'53"E 126.60 -' 8 - p. _ > V + f rl 1° I m \l 1 Ci C7 F--1s r $z -- --I ;O2 L1AnANIr A I -- oz's V r\s \I V I J �� - cxxI cnm L.V I �^ 3 d 3 z N o x,_ S 1§11 x 61 G7 -I W P4,;-17% 1n _a w N'-' Z r 'T1 1., ,,. F•O ' c iO A 3. m•� R ,p og w O Z 0 14 O r. O E- - R,g' P<tl gl o nm .-04 O w A gIIMHII1iF: 3 m �3� Ca v m °n c _•1 n u n s Z '1° •�3 m g 5f a o o 5 2 'Tl to N 10 C X a 1, g �. W m4 Eitit ymp N -0 ZI mF% C1 r '�o�rw I— V sXs E.m5ma,••4cm 4:4q - P , C3 14 n1v D 1 417::,' -_I d zir al#,ER 9.g.. al , 3 "' Z 8X33 m ra �'Pa 0 m O -; o 3o �d� 3gg n IIH *I�n °E '3.115 : Ns �° c 3S 5: 3-3'; " ,.3. -014" 3t 33 3p W A R W O pN 10 a 6 R CERIIIICin �, James .11 9 gi gS , 9 le2A -110A 110M04 At -,mom ( / /SURVEYORS qI z g e i' CI Lot 10,Black 1,DAKOTA PAIN 5TH 1 - A ,_7 2500 PEST COUNTY ROAD 42.SUITE 120. ADDITION,Dakota County, Mnlnaaota. B 5541711E.104 55337 - '`_ P00 52(952)890-8014 FAX(052)090-8244 . I I Gg 1o3e.4 -y- , , • ,,j:aii ii I I :� GF 1036.9 GF 1037.3 1 I T W08 �- 1 Sn 1 GF 1033.5 I I GSE 1034.7 I _L0380 51TF 1037.7,.. LO I I L I LO 10298ILO 10313 t.� 24OD/ _,u 41) l,,,,,„ 111191111.1111111119 I I AG:10110.2 = isik" °o14 I1 AG:1029.2 I I AG:1029.7 \ I 1 I ,j, ..ts. ,„, �_' i1 „ 404 ,, 1,ft. int r WIJL . 'Vll . ;01 um6pip 4 - I, ,,. ., w-'d 41111.1111' ,,r 1 1 11 1 1® I 91 Wig iiikiiiMil izi 8 glair"- m, . „� pr, AG\02p.AG:1029.0 A,G�103 0,2 1 AG:10318A 1 f AG,/1111011111011111* 8 0 . 12 ! I 1 H, y F 102 3 ��ACTeGirlI n B 1 1,8 000.1.0 4�ie, R��i.13J L• �. :F 0 ,a��. �_. 1 yi 1p . •` ' ° (� '(Ft1®.3 1 "TWO6Iir,7T6 I r 05ht ii r ` kik AL 1 GF 1033.2 I I GF 1036.5 IIOF1039.4IGF 1041.2 d I GF 042.5 �1 ;. t- F w ��► - ., eaka 1 1 r..., _ �"Ns of 1 2.1 Z (2 411 .-'' A '::4 i Ai ,,. MI .:'-1,.)- 'I,- alio - - j .._. gE-6. ricice al w ,,,:l ��� ---.441Liwiimiii0 ERL'DIEU, AV INIMININIMk OW Q {a it ' A I I II"FA IN I WA 1 I I WI - 1 4 1 .,...,,,,, . ....„,:.;LI .) Plk.111511031111111.1VMMTMTIVMM=a1111410110,.____,,e 4 - iMpriviiiiiiiimiriaiffilifilliellrAimmer.--. - : \l' ./' c:' • Iltia0 °Pr. ii*O-r- 7 iffialliri 'VII 1 „ GF 1033.0 GF 1035,9 ` iv,41.1.41111) 1% , , 9.5 I 1 GF 104E 101. , 4.0, f **TF 1034.8 I `TF 1037.0 * 4 .6 1 TF�4i I,/ / TFB I LO I OLill . 14* ` BF 11 6.8 1 �.ruarw=+ ••�•_� crrzn, TFC ,,":i ( /t ' AG:1034.2 I AG:1031.6 I I AG:1032.0 I I- .--- 1 L_ __ - -_J i I AG:1033.3 !/ -"'4, ..9 , : w► . �• - mik6 � �` '°fie .04r: '= ''''/VI i (if , -..-- .. iik,sw, 14 -‘fd.,,: ,,, .-:-,L ,,,. ./, .4# lt:kil: 111*--L-4. 0- 4111161/4, '-• '111141 -710: - , .4•1111114‘1\44kNt4ti sol, m AS 3 AI gl.11414411 iz--,-, -quirir--.4%,4.4.44474- ' : ,, 7,,, 141, -"N. - wiliv„: Altromaill z- , , ,, , A- /101114it .--- ;,1'• ilkil ' 7 r i -0;:, :. „ ,..„.:,,,, , „ : 0 iz .. , , , , .. 4--€.. ..,,, „.„ r 4,474.19 /111111111111 attSiii 441, ,4_ 4 NAL . :, ,i . 1 or,, ;.,„,,,,,,,4 !,.440,1‘ , , • , 4.,..), c 17k•Ao-44 4 Oa 2- . dir 'el. /114-*1., *4 Ar,,, GX^ Olt? w i 3 / i -4LN:.4.Nibillio :1141404\bs.......... 41116,..„ . iaii):7,5- / .8 /// stilip. _ ctte.,4004100,,v. \ow Ir jjk -- ill'i il 411111 "--- '‘."S. ',.. ' if / ' ."lillikk,..„ ' liPif 0*-70 ° lir #1°.cc- --/ , \''''ti...1411P--•‘411411114*Z.P I I iiiii 52 / / 1 i I;o4ss •./ , / � ilk.' f \' \ :'° psi •� �a-/i/ •, �✓ r►''-' 706.,..5-r ``• L / t0 / fi A' \ / / la_' �� q �{/ � \. '''''"21. . .. / '+� \ / �''F,_S3�._. 3 , , LOT SURVEY CHECKLIST FOR RESIDENTIAL / V/ 3 9 $ BUILDING PERMIT APPLICATION ,(' PROPERTY LEGAL: / i � 1. 1644 .)--i-a_. r�/ J A ' DATE OF SURVEY: J111/6 LATEST REVISION: d c /. 7 71-7)11-6-fick&q- -.0 , s a O z Q DOCUMENT STANDARDS A ❑ ❑ • Registered Land Surveyor signature and company A ❑ ❑ • Building Permit Applicant ❑ ❑ • Legal description 4 0 ❑ • Address x ❑ ❑ • North arrow and scale eH ❑ ❑ • House type(rambler,walkout,split w/o,split entry, lookout, etc.) )2' ❑ ❑ • Directional drainage arrows with slope/gradient% X ❑ ❑ • Proposed/existing sewer and water services&invert elevation ,H' ❑ ❑ • Street name f2( 0 ❑ • Driveway(grade&width-in R/W and back of curb, 22' max.) 1 ❑ ❑ • Lot Square Footage A ❑ ❑ • Lot Coverage ELEVATIONS Existing /1 ❑ ❑ • Property corners / ❑ ❑ • Top of curb at the driveway and property line extensions / ❑ ❑ • Elevations of any existing adjacent homes 7 ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches ❑ / ❑ • Waterways(pond,stream,etc.) Proposed if ❑ ❑ • Garage floor ikr ❑ ❑ • Basement floor ❑ ❑ • Lowest exposed elevation(walkout/window) / ❑ ❑ • Property corners / ❑ ❑ • Front and rear of home at the foundation Y 1 • PRV Required PONDING AREA(if applicable) ❑ �( CI • Easement line ❑ .rte ❑ • NWL ❑ "d ❑ • HWL ❑ / ❑ • Pond#designation ❑ / ❑ • Emergency Overflow Elevation ❑ ,E! i • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS ❑ ❑ • Lot lines/Bearings&dimensions 7,,( ❑ CI • Right-of-way and street width(to back of curb) /.. ❑ ❑ • Proposed home dimensions including any proposed decks,overhangs greater than 2', porches,etc. (i.e.all structures requiring permanent footings) ❑ ❑ • Show all easements of record and any City utilities within those easements y ❑ ❑ • Setbacks of proposed structure a sideyard setback of adjacent existing structures if 0 ❑ • Retaining wall requirements: Reviewed By: iA:� i Date 3 %7 G:/FORMS/Cert.of Survey Checklist Rev.3-3-11 IF 4429-068 (ZS6) :XYJ t1•09-069 (ZS6) :3N0Hd M 0• r- L££S5 NYV '311VASN2lf18 o}osauulw 't!}unoq 010)100 'NZIiI00V } N Z W 'o mins '1.4 ovoei ALNI100 193M 0052 H12 HIVd VIONVO 'L �i0O18 Ol }01 LO N Z on f- r¢rl O Sa0A3Aaf1S / Sa33NI N3 / Sa3NNt 1.d glacilIW®[ - 2M' 4110121011 �f a f z w, 5 N 0 o p W o i ' • sewer X03 ® � O r 0> O _ II. guns do gyar aa cn � 0 t vsC +., O L. ro a +. COV cc cEo ° oo � vo � w o ° • n\ oro ro c �" 1 `COv ° -0 v 0 o ° aQi +, �, O o u S a c o O L: u o = E o f x To O `^ t >` '1 a) ' 0 �' > ° a u ' v 4- aJ \ s? O A U O r-i '-• t 46r° sr:3- aJ L. 'x .. a) 0D C tD r-1a.-J 0) To ro c -° Etc o m ° = N Y N 3 c $ C3 O ° 0 0 — C L' v E • tD O U u1 M u„ +3 4- Y ri ° y CO 00 00 N r^ t U N •In Z ro L ut C 0-_ MI a O0 t19 — N • N V, O +'' O n't (a a) u, 2 y 0 Y 4"' LA a1 c 0 CNI 0 M ran M M O N a.T c � no -a .n 0 V C O I-I t` Q O 0 O O L. L N — '~ O o °- ++ C c aJ 1EO -' I I 'a O0 i-i r^I .-I r-I O O j� L N E wi o0 -a 4- miti = a1 a, o Cl. -, •a) c CO a u n ty II Z vi.) o CO ¢ c $ 12 1-ao � oE 'XJa a, .a v ° tD O • •• v.c W c 'wo +• Z I=- C i- c d O 4_ -roi `1 ,, cu a) N _ ro V. N V> • N ty (C t o to ° 3 ... ° p O c E 3 O ' o 0 i Y - � c o O = c o c a:� B O 4 J 4 c '1 o J 0 a� 4, L N F- �- CO c ,C L.(aU N - :-u c CO 0 v > •t I- CO ai ni rn 0,�:c IL r' 0 t < W I'`'1 0 c a1 > 2 MI a) >,t o '"L E > < a)a) Z 0 II II II k I- N C c c L. no ct oat c y w c W m 0 J ce ro c a1 z U > �, ` �, '^ o v no O a1 i;s v ¢ " +� Q0 W c E •►- C/) U c 0 y _. a, a a ° a a " ,;� I-- c _e U u U +� ° y 0 W < 0 p a) E c o m +- 'o m m c c c Cr) c < o u u `o s .� o ro > o D o 4 c '- _ ° c .� u m 00 a1 ro > aL c O tY a Cn 4 a1 as -o 0 CU c H u H C 4, c a 4- au o o c �z Q s -I o co a Q p oN ° `-I CO •� v u m a1 =a . 4_ W a1 v a a QJ a .. E ° z c ° + o >y ` m ro = 4.4 �. u' o u_ 0 C7 W W >. u Y aa) Y LU m W _c W mm 0IDZa !_^ Z a oa -oWWtno. U 0 ~ v1 D y 3 �► > a' o c -a 3 p6 p N I- Z Oas 0;3 = a1 W In v v ,� c ` Ce .8 Et N O LU o J `ro CO` 0 0 Q o 0 .? Q D s �., E s nn 1.- CO a- a aL -i Z r-i ni m Iri to r` 00 03 I- W 0 0 I � _ -1 = C] O CO - E - •- ✓1 N 2 I /1 1 YY� '_ c J -L_\-.) 1 a 1-*----0£-----.- C� I N fV�V /� M�0 r - V �1 V V �/ V / \ Tq II -- ( za>' - I- - w3oL 5G 0 () ka -01 I -J N4. 1 <C N �-- 09.9Z l. 3,�cc,Z L°00N , --� 03 C84 , 8'1 O . 4'9£0I 00'irk' - Str'££ k--- 17--- (L'0£oL) ).'74(C9£0 l)� •A.1 _ MX i 00 i f .`t ro f L 9'L£0 t l'L£O l q G1 kJ 4 Li 1 O 0 I 4z I (•0 in 1 `°; ON WQ \\ Z- zmrn O rQ �a Nr' I N a) Owihi •Z 11/41 - - i`-' 11 0 fr 6 g 1 cp.-0 N \ i' HAIL h > ,k1 CL I F-...r.,.. 89£Yl0~ CC O C _r -� - " w (/) L02 LCI-j, � TZ I� N , SnOH x�, 1 (0 cr1p) LU c.)F" C) < 0 z v w ., - I aM d02id `v N CO 7\ L t; 1- pew xo �. 6'9£01.�r `-G'0£�---+- 1\ 0 G � `�\ � 1 -og St. 0s9G-< � _ 8 3 /' �' ��--r ••, 0'9Z0�>��--.---(9.9Z0�)'` -- (s s£oG)►\, -- o x . ',kip t7 4'szo1. 6'020 I. - 0o'bb -- 8S'Z£ ao M N�,1 Z `-- b�'SZ l 3«�s,Z I. —'N 0 f�' _ N o I 'c4'9£01. ; It: ^ ! f�F�� v N I \ 1 0gift \ g C - O - ,w I � , (, — I I ' a C 1 O Y W a) cn C� �� Y¢ --s G-► >,• co \[7 , O E -E <C C) C- \d L - - - Zoll to C \ \ \ w a,? --o£^----.- .., g F -cc \3snoH, °°o L, +?� a 9NI1SIX3 a ,-- a—\ .. j oE▪ a' c 0) > M C ° E c c .-0 o CcoQ t o• 0 a v -a v - u 00�cc •a a o Co-, . ca 1o.I- +� oXo in in O. a o. w Z II c c °c c °c °c c a1 a, a, v a v m OppL] ppp W 0 4*,C too lavii Z V! 0 0 o Z� ►. o M o Q 0 • 0) 0' Page of BRAUNc t-dsan 4/07 I NTE RTEC Daily Soil Observation Notes Project No.: Date: 9 13 '1-, Report No.: Project Name: 1112... ‘r". ` c ',lam Project Location: Lof 1 U , ( , U, (` ,-7k Vic- ( �` • Client: )gt"� Temp/Weather: Ct ,/ et4 6-b Project Manager: ! ^.-., )")e .1. 0.''' ( Time Arrived: Departed: Areas Observed: O Building Pad 0 House Pad 0 Roadway 0 Pkng/walks 0 Footing O Proof Roll 0 Other (describe) Soil report available? 0 Yes Q No Report reviewed? ❑ Yes 0 No Report prepared by: Get copy Benchmark: i.,,_� S-},.l'l Benchmark elevation: ,, Benchmark provided by: ' -. Finish floor elevation. 1- �, Bottom of footingelevation: iy Bottom of excavation elevation: , ' Approved plans available? Y{j Specified compaction: Fill source: Oversizing appears adequate? 0 NA ] Yes 0 No Soils observed agree with Soils report? 0 Yes ❑ No Soils appear adequate for design loads? \g] Yes 0 No Proposed project bearing capacity (psf): s .. Contractor notified of results? ] Yes 0 No Name of person notified: Was a copy of this report left on site? VID Yes 0 No If so,whom was it submitted to? ILs NM ' ' Eirmitaw ..5‘ Mr ,w 4 ail 1 MI Ill ,A' rillal • • €, 0 . 115211111111111111111111111.1101-11111111' ' ' 11111111211 IIIIIIIIIIIIIIMIE . .. OM ............,...._ 1,......r., r t ! NI 111111111111111111111111111 �� -. illillIIIIIIIIIIIIIIINIII 111 , Mr = IMINIEfillEIMI IIIIIIIIIIIPI _ , 1- E ' 11111111111111111111111111111111111111.111111 F 11111.111111111111 MOM _ Notes/Comments: .1----6 1 b i I. ., . -1----- /0 c-i. z i 1 ,i f WriteAbpttom :levations, date excavated, oversizing and type of bottom soils on sketch , Performed By: /:-:-., '-. Reviewed By: Date: This is a preliminary report and is provided solely as evidence that field observations and/or testing was performed. Observations and/or conclusions and/or recommendations conveyed in the final report may vary from,and shall take precedence over,those indicated in a preliminary report. e Providing engineering and environmental solutions since 1957 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA145290 Date Issued:09/01/2017 Permit Category:ePermit Site Address: 1272 Interlachen Dr Lot:10 Block: 1 Addition: Dakota Path 5th PID:10-19544-01-100 Use: Description: Sub Type:Residential Work Type:Underground Sprinkler System Description:PVB Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary:PL - RPZ/PVB/Lawn Irrigation $59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Dr Horton Inc Minnesota 20860 Kenbridge Ct Ste 100 Lakeville MN 55044 Sabre Plumbing Heating & A/c Inc 15535 Medina Road Plymouth MN 55447 (763) 473-2267 Applicant/Permitee: Signature Issued By: Signature City of Eapll Address: 1272 Interlachen Dr Permit#: 141633 The following items were /were not completed at the Final Inspection on: k// 1 Complete Incomplete Comments Final grade - 6"from siding )6 Permanent steps - Garage Permanent steps- Main Entry Permanent Driveway X Permanent Gas Retaining Wall or 3:1 Max Slope w6,- Sod / Seeded Lawn f\JON it, Trail / Curb Damage /VC Porch 1\i' Y\11.d Lower Level Finish Deck Fireplace • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. , -"------ ) ___----27 Building Inspector: V `71- G:\Building Inspections\FORMS\Checklists