Loading...
3385 Central Park Village Dr Al i Use BLUE or BLACK Ink `� C For Office Use C � �'t-, /� ::::ee: : 2 - . Cit. of Eaaall 1 3830 Pilot Knob Road l��_ Eagan MN 55122 t -, `t Date Received: ,)/ 1 Phone: (651) 675-5675 Fax: (651) 675-5694 Staff: 2017 COMMERCIAL BUILDING PERMIT APPLICATION Date: 03/20/2017 site Address: 3385 Central Park Village Drive - Eagan, MN 55122 Tenant Name: Bank of America (Tenant is: X New/ Existing) Suite#: Former Tenant: CSM CENTRAL PARK COMMONS LLC Name: Phone: Property Or 500 WASHINGTON AVE S STE 3000 e �� Address/City/Zip: X Owner Agent �i Applicant is: Owner Contractor j j f 1Ncrrk f7:::::''':'-:;i:'--‘'?-.,,:::-* T .o Description of work: New Bank of America Building �e 1800,000 44���;` :1' e, Construction Cost: ' ��w,,,,, ' 4 Name: 64rdoer gk;i C$ License#: yp 24. Va. �� - "1y� Address: 5u0-4e. /Z33 il?:""ein/+SC � frCt+{3n (ci IZ `T 40State: �� Zip: SS 4162- Phone:4 fr. Email:k Contact: e . � S�' 6e-i4 h g 14.1-�r•t4--*O:"/dCr3 , cs r, ,,�\*,, Raymundo Fieto 53754 \� Name: Registration#: O � 945 N Penssylvania Ave Winter Park Architect/Engineer` Address: City: %ij FL 32789 407.629.1188 %i j j L State: Zip: Phone: Nelda Molina NMolini@adcinternational.net % Contact Person: Email: Licensed plumber installing new sewer/water service �► Phone# c5 47 -112 NOTE,Plans and partin77'g ca o uments Lice ou submit are onside ®�`t j ublic info �o a " ° -' the rnfor'matio ma, be classified as non ltc F ►f you�ro�tc%s�ecrfic reasonset wotl ���r � �� , ,,, conclu %at the re ra a secrets a CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which requir-s a review and approval of plans. Al / x Daniel Savage X , ii/4, Applicant's Printed Name Applica is Si °- Sc\✓`k v I J O t1 t S CA Page 1 of 3 +l n ^‘ ty- 4_1424 ( (//,'W . tiir /4 6. Pi2 - • -D DO NOT WRITE BELOW THIS LINE / L'�2 4c� SUB TYPES Foundation _ Public Facility _ Exterior Alteration-Apartments }S Commercial I Industrial Accessory Building Exterior Alteration-Commercial _ Apartments _ Greenhouse I Tent Exterior Alteration-Public Facility Miscellaneous Antennae WORK TYPES X New Interior Improvement Siding Demolish Building* Addition Exterior Improvement Reroof _ Demolish Interior Alteration Repair Windows Demolish Foundation Replace Water Damage Fire Repair Retaining Wall Salon Owner Change "Demolition of entire building-give PCA handout to applicant DESCRIPTION / Valuation !k)86*,oat. Occupancy 9 MCES System Plan Review / Code Edition ea is me G SAC Units 6 V P iGkv- (25%_100%✓) Zoning City Water Census Code Stories I Booster Pump — #of Units I Square Feet 37(5 PRV --- #of Buildings / Length Fire Sprinklers — Type of Construction �a Width REQUIRED INSPECTIONS X Footings(New Building) Final/C.O. Required Footings(Deck) Final/No C.O. Required Footings(Addition) Other: x Foundation X Foundation Before Backfill Pool: Footings _Air/Gas Tests Final Drain Tile X Siding: Stucco Lath _Stone Lath-X Brick EFIS )( Roof:_Decking X Insulation _Ice&Water x Final Retaining Wall )C Framing 30 Minutes )C 1 Hour Erosion Control Fireplace: Rough In _Air Test Final Concrete Entrance Apron Insulation Meter Size: Sheetrock )C Electronic Plans Required Windows Final C/O Insp-^*i^n. s nWRAule Fire Marshal to be present: k Yes No Reviewed By:! Ptirft a"--4Z-1aK , Planning New Business to Eagan: /C5 Reviewed By: . ___-- , Building Inspector FEES Water Quality Base Fee 91-46,� Storm Sewer Trunk — AV Surcharge 844.'a Sewer Trunk — Plan Review 'i S 9 S 1, 8� Water Trunk MCES SAC Street Lateral City SAC — Street — S&W Permit&Surcharge /91.64)y" Water Lateral Treatment Plant ""' Other: — Treatment Plant(Irrigation) — Park Dedication At 3 S 3 SS6&2; Q Trail Dedication -- _ TOTAL 4t /9 6&2;r L- T— Page 2of3 . • • M£ES USE:Letter Reference: 170403E4 Address ID:710960 Payment ID:400958 (,l‘? Date of Determination: 04/03/17 Determination Expiration:04/03/19 Greetings! Please see the determination below. Project Name: Bank of America Project Address: 3385 Central Park Village Drive Suite#/Campus: Building K/Central Park Commons City Name: Eagan Applicant: Daniel Savage, Nationwide Permitting Services Special Notes: None Charge Calculation: Office: 2279 sq.ft. @ 2400 sq.ft./SAC=0.95 Total Charge: 0.95 Credit Calculation: Central Park Commons (SAC 07/16)—3325 Central Park Village Drive Retail: 3425 sq.ft. @ 3000 sq.ft./SAC= 1.14 Total Credit: 1.14 Net SAC: -0.19 —or— 0 SAC Due The business information was provided to MCES by the applicant at this time. It is the City's responsibility to substantiate the business use and size at the time of the final inspection. If there is a change in use or size, a redetermination will need to be made. If you have any questions email me at:cory.mccullough@metc.state.mn.us. Thank you, Cory McCullough SAC Technician Please visit our SAC website by going to: http://www.metrocouncil.org/SACprogram 390 Robert Street North I St. Paul.MN 55101-1805 /36' Phone 651.602.1000 I Fax 651.602.1550 I TTY 651.291.0904 I metrocouncil.org METROPOLITAN COUNCIL An Equal Opportunity Employer aA J. , \ ) y UO . PI) - o w w ^ o �Ns$ 3 1. bA 3 vf i�d M a II s&'lgig : - a 0 N.t-1/I 01-F9 — .t-pi � ,II 1/I F) _II.\ I I I .E/t 01-.W I 1 \ (i .1 I ti, ,Y/I 9-AY unr,,1 1 1 e_` IN lTll r 1 -1%[] ---}-- Irl .)---"L''at : —0— § iP_.L MON I I .s.#. 7 11y 6,':6p '.4.0) IGI .t/101-,Y1 A-9 'A-) � A All Il-Ft A' .lJll Y-Fl b �i ll A-A I" - 6 IN lul. t. XL 0 i ri F W �a6 iOws B i■q�irrs�e�i■�� =I t:� W ._..v+ . E_ �. jil ,,_ _. .Z/ll-,LI i4 1 �� o[ col z/Ie f;.. - E f AI's Ig �I[�i <'� II 1 2 Ig I a as 1 in flit ars �i s 15 a 1 3 JLy I 9Y �'1 \e II I a €6 1 e a ®— A ; p _. - illr i 4 4/\ , i, c. . --- _2/I, ^ ll- zn .„ r-i ,-, ®, ,,,I- ( l/I I-.0^ .a✓✓t c-$1111 , _ I _ rte- I _ u r N e-- �.– fi L I , I I a a P � ii- �— la a 1 I� x y,eLs of .e z/Is-< [ �_ _L_ , �e� R ® _.... �1)1 77—17— mit- �I,_ W h ! 0 9 o_i 1. I 2 1 Op AA I • II rO .Z� ll-o B � -6 4, r 1 s a ` ' > 1 i1 :; 1 Hill y 1 w ' } 1 ,S.® = , o ,_1. i,,� o '_!_ U 4 � S 3d I.i G G I N g ! W z 9' o_ O_ I - NI - w— I 1— Q C \i c0 1 pi' o O— 1 i 1 io— IgEl g1 ® a ! I t1l Z-,ol ,Z/I I-Pl .Z/I I-.ol I of sol I -� 1 GE1� L�° �, Q � r� J ail _ III �� �= __ 0— -fi „ �Qa I Ill' ' t o .-1_r 00 O O O 0 O ! I 1 1,,, ,IL, aE I 1 ' I .v.0-A I 2,t ' .0-A '.0/t! .0-.9 /it 0-1,9 ' .-A '7/I9-!' .o- .Y-.I tai$ I AS 00-,95 .0-9 *a E 00 0 b b b .$$$-$ttl_Fa b1 b b b = w Y (Dee 00 000000 0 Use BLUE or BLACK Ink City ((}} Eaiali For OfficeUseJV ZCC'17 (� Permit#: /-177q - Permit 17 7 q`d 3830 Pilot Knob Road AV s 1. '\u^5 /e/ Permit Fee: ' c Eagan MN 55122 l Date Received: �'���( Phone:(651)675-5675 � Fax:(651)675-5694 Staff: f )(5 J 2017 COMMERCIAL PLUMBING PERMIT APPLICATION ❑ Please submit two(2)sets of plans with all commercial applications. Date: 4-28-17 Site Address: 3385 Central Park Village Drive Tenant: Bank of America Suite#: Property • - Name: Bank of America Owner Phone: `, Name: Voss Utility&Plumbing License#: PC000306 Contract©r Address: PO Box 240 City: Hanover State: MN Zip: 55341 Phone: 763_497_4577 Email: vossup@comcast.net New —Replacement —Repair —Rebuild Modify Space Work in R.O.W. Type of Work — — Description of work: Plumbing for new bank building. " ` COMMERCIAL X New Construction Modify Space Irrigation System(_yes/ no)(_RPZ/_PVB) • Rain sensors required on irrigation systems Permit Type • Avg.GPM (2"turbo required unless smaller size allowed by Public Works) t� Meters Call(651)675-5646 to verity that tests passed prior to picking up meter. Domestic:Size&Type 1" Fire: 1 Avg.GPM High demand devices? Yes No Flushometers Yes No COMMERCIAL FEES Contract Value$28,540.00 x.01 $60.00 Permit Fee Minimum =$ 285.40 Permit Fee $60.00 PVB/RPZ Permit(includes State Surcharge) =$ 60.00 Surcharge Surcharge=Contract Value x$0.0005 If the project valuation is over$1 million,please call for Surcharge =$ 14.27 TOTAL FEE Following fees apply when installing a new lawn irrigation system $ Water Permit Contact the City's Engineering Department,(651)675-5646,for required fee amounts. $ Treatment Plant $ Water Supply&Storage $ State Surcharge _$ 359.67 TOTAL FEE CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. \ I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x Steven Voss x Applicant's Printed Name Applicant's Signature FDR OFFICE use , Approved �� � Date:� 17 /1,7 Required Inspections: '5der Ground " i o gtlin �,lAir'TT'est 0,4,,4 Test Final PRV '2equiretl Yes: No Meter Related`Items " Mater Ike ,"1 , Radio Read; nanometer Staff: ' Page 1 of 3 Use BLUE or BLACK Ink ofCity'*". Eapii For Office rs 'el Permit#: Use-/ ��� �� �0---5-7-73'.-711 �� 3830 Pilot Knob Road Permit Fee: Eagan MN 55122 Fi � Date Received: --', 1 / Phone:(651)675-5675 Fax:(651)675-5694 Staff: J 2017 MECHANICAL PERMIT APPLICATION ❑ Please submit two(2)sets of plans with all commercial applications. Date: 4-28-17 Site Address: 3385 CENTRAL PARK VILLAGE DRIVE Tenant: BANK OF AMERICA Suite#: Residemt/Owrler Name:BANK OF AMERICA Phone: Address/City/Zip: Name: VOSS UTILITY & PLUMBING License#: PC000306 Contractor', Address: PO BOX 240 City: HANOVER State: MN Zip: 55341 Phone: 763-497-4577 Contact: STEVEN VOSS Email: vossup@comcast.net V New Replacement Additional Alteration Demolition Type of Work t Description of work: GAS PIPING NOTE:Robf mountedand ground mop,- , . ineoha , .u pi t Is quiredtto be screened bode. Please cont the glieohaniciti Inspector toeinformatioh on,permittedeareesinit* ,e RESIDENTIAL COMMERCIAL Furnace New Construction Interior Improvement permit Type _Air •Conditioner V Install Piping Processed Air Exchanger _Gas Exterior HVAC Unit Heat Pump Under/Above ground Tank ( Install/_Remove) RESIDENTIAL FEES 1 $60.00 Minimum Add or alteration to an existing unit, includes State Surcharge $100.00 Residential New, includes State Surcharge =$ TOTAL FEE COMMERCIAL FEES Contract Value$ 1585.00 x.01 $60.00 Permit Fee Minimum $75.00 Underground tank installation/removal, includes State Surcharge =$ 60.00 Permit Fee _$ .79 Surcharge Surcharge=Contract Value x$0.0005 If the project valuation is over$1 million, please call for Surcharge =$ 60.79 TOTAL FEE I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit,but only an application for a permit,and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. x STEVEN VOSS x \ --"X.v__ _It,),IN _) � Applicant's Printed Name Applicant's Signature FOR OFFICE USS ' -,, , ...°: k,': ,- '', -,..P1;r lti, Required-Inspections 1 Reviewed By Date /-"‘„,,, ,4%,/,.....„ f'7 Underground M r Rc�u h in : �' g Air Test �' Gas 8ervi Test Iii-llcgr Hest Final, HVAC creohingScreening Cl7 6 G Use BLUE or BLACK Ink I 1 12/741) X' c (d s 1 For Office Use fL..(3/qc( City of Eag,a t ( I' ermit#: ô2c03 '3830PilotKnobRoad P ��� ermitFee: �Y Eagan MN 55122 RECEIVED Date Received:_5_ e7---(-47 Phone: (651)675-5675 Fax: (651)675-5694 MAY 2 42017 Staff: PI J 2017 MECHANICAL PERMIT APPLICATION ❑ Please submit two(2)sets of plans with all commercial applications. • Date: Site Address: .395 CC1i 1 .4 l) P rk V/%/4 f?J 1)fI Li e". Tenant: ! a O- T"-"er1 ec Suite#: ice. Reside rtto ner� . Name: Phone: lmp�liGt : A .. tit : . Address/City/Zip: t1 ,%, , ,: Name: 0p/7 vr1P - .A41IG.ot! $ i -A.,5License#: ' /M1a -'-'---t,' Address: SO3a tVx .r >iiiCity: L1tle ('-' ,"101,674 Conteketor k * ' ' i . State: Mn. Zip: 5-51/7 Phone: ��m � Lib 4.- Z �3 - �;h Contact: rick rtleJe.Gl Email: rl m fr)4 i fir-( - .„, I ,..) I'' ) New Replacement Additional Alteration Demolition `� '; 0 Typ of Work , Description of work . = - i .. f � —OS'////if. i i`1Z)1(AAvci-F4its 1,-,'.1_- 7 s- ..., ">j M),wi u., e aiv7 ,Gv it ro'a vv?K„e t: m. „ 44;g, NOTE: Roof moocuntes ' • round mou e• , r ha fcal equipm t ps required tp be cr 'ed by City 11400#41ru ° " Mechanical Ins ec aid orm do n py itted scree in 1 ds. 0 Code, Pie �� ", -,-- ,1r-,':,� RESIDENTIAL COMMERCIAL . -,'� *,,04,,,,, ^ k, _Furnace x New Construction _Interior Improvement i Permit,Typo:- T. _Air Conditioner Install Piping Processed ';":""i''''''' Air Exchanger Gas X Exterior HVAC Unit ti +lHeat Pump _Under/Above ground Tank ( Install/ Remove) s0,001,,,,i1,00,---- Ir ,- Qio Other RESIDENTIAL FEES , $60.00 Minimum Add or alteration to an existing unit,includes State Surcharge $100.00 Residential New, includes State Surcharge =$ TOTAL FEE , COMMERCIAL FEES / Contract Value$ ` ZZ ,a V &3(.01 $60.00 Permit Fee Minimum / $75.00 Underground tank installation/removal,includes State Surcharge =$ ` Z>>ZS Permit Fee =$ .14, iW Surcharge Surcharge=Contract Value x$0.0005 If the project valuation is over$1 million, please call for Surcharge =$ 44'3 $4, TOTAL FEE I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan;that I understand this is not a permit,but only an application for a permit,and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. . -,-- x,,,6.„...., x R/6/k g Live") x Applicant's Printed Name Applicant's Signature 'till - y ` �', -15 ars;"d uAlwi �, i i mR ,a v u,. FOR OFFI`f USE t .: H4 . w,l a � :,u *1 i (i a � ;,€', "-SAP a 1 444 "�`'1' q '1 9X11 '' �' v va o- „ �;I `, x . v 9i u '; h `ERequired Ins"`ection�s '--72.441,:g.-„,. ..aRe ie opL.. ry _ . ^- ..-? r .�" i :°""� iii ; � �1 Y�"m e fil i � �9 z-=.,.�.'v, a ! ," �°" VA �::'. c,T ;r" N1 -..NI II�tihjtli ` . .r5iµa;,f,Z,L A„, I Y>try.'? 7„I�0,41.: :1,0 r':.5q L7s ps ,,t .'44'7,- ;�4 , _. Underground l - `,9,uugh In l' - Air Test . ,X`�Gas�aSry ,ice -= ` In-floor meat - final .`HVAC creentn �h 40: d. ` Use BLUE or BLACK Ink i For Office Use /647 --- --3.-6 Permit of Ea an Permit#: Permit Fee. /q �q c:, • •-• 3830 Pilot Knob Road / Eagan MN 55122 ` l? i Date Received: 3-)1(1,:), Phone: (651) 675-5675 { Fax: (651) 675-5694 Staff: , CiP Lt) /qg- -Z 7 , 2017 COMMERCIAL BUILDING PERMIT APPLICATION Date: 03/20/2017 Site Address: 3385 Central Park Village Drive - Eagan, MN 55122 Tenant Name: Bank of America (Tenant is: X New/ Existing) Suite#: Former Tenant: Name: CSM CENTRAL PARK COMMONS LLC Phone: Property Owner 500 WASHINGTON AVE S STE 3000 Address/City/Zip: Owner Agent Applicant is: x Owner Contractor Type of Work Description of work: New Bank of America Building Construction Cost: 1,800,000 Name: 6 t d r of ewe/Cle.r5 License#: Address: 730 " 2 ��Fl1)s.. 5, , s�.i - i233 City: 41:1nv ei /+S Contractor /140 � �, �' State: �t ) Zip: SS �'D Z Phone: (i €12_744- /y/7 : ' Contact: ee14 tbitSTGrr,r.m. Email: 6tf--/.1.,...) g ii..c r.t.-- :.,."/derS , c.v., Name: Raymundo Fieto 53754 Registration#: 945 N Penssylvania Ave Winter Park Archltect/Engineer Address. city: FL 32789 407.629.1188 " , State: Zip: Phone: Nelda Molina NMolini@adcinternational.net Contact Person: Email: Licensed plumber installing new sewer/water service: 1)t r /. Phone#: (0a% " 047- ��6 NOTE Plans and supportingdocuments that you submit are considered tefilepublic inform oto Po ?ei "o the information may be classified as non-public if you provide speck -1 ,reasons-that would rm�he i I concludethat the` are'trade secrets w y "4 . :. _k t 4 , CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requir s a review and approval of plans. 1 i x Daniel Savage x A-4wPApplicant's Printed Name Applica is Sig a Page 1 of 3 ���6 ( IvK ill ll4 6 .02 � � DO NOT WRITE BELOW THIS LINE A/2 ' 1 SUB TYPES _ Foundation _ Public Facility Exterior Alteration-Apartments X Commercial/Industrial Accessory Building _ Exterior Alteration-Commercial Apartments _ Greenhouse/Tent _ Exterior Alteration-Public Facility Miscellaneous Antennae WORK TYPES X New Interior Improvement Siding Demolish Building* _ Addition _ Exterior Improvement Reroof _ Demolish Interior Alteration _ Repair Windows _ Demolish Foundation _ Replace _ Water Damage Fire Repair Retaining Wall Salon Owner Change *Demolition of entire building-give PCA handout to applicant DESCRIPTION if I Valuation l�8 o/Das Occupancy Q MCES System Plan Review / Code Edition Zo 1S me G SAC Units 6 7 4,k(-- (25% 100%✓) Zoning City Water Census Code Stories I Booster Pump — #of Units 1 Square Feet 3705 PRV -- #of Buildings f Length Fire Sprinklers Type of Construction 116 Width REQUIRED INSPECTIONS X Footings(New Building) Final/C.O. Required Footings(Deck) Final/No C.O. Required Footings(Addition) Other: X Foundation X Foundation Before Backfill Pool: Footings _Air/Gas Tests Final Drain Tile X Siding:_Stucco Lath Stone Lath)( Brick_EFIS )( Roof:_Decking X Insulation _Ice&Water )( Final Retaining Wall )C Framing 30 Minutes X 1 Hour Erosion Control Fireplace: Rough In Air Test _Final Concrete Entrance Apron Insulation Meter Size: Sheetrock X Electronic Plans Required Windows Final C/O Insp•'' 'n• 941nbfaAule Fire Marshal to be present: k Yes No Reviewed By:! PA- °'^4?ra.k , Planning New Business to Eagan: /C5 Reviewed By: "ar , Building Inspector FEES Water Quality if Base Fee 91SG,IL Storm Sewer Trunk Surcharge £3Z4•_ Sewer Trunk Plan Review 'l S 9 S 1, 8-9 Water Trunk -" MCES SAC Street Lateral City SAC -- Street S&W Permit&Surcharge P -1.Do•••••=. Water Lateral Treatment Plant "' Other: --- Treatment Plant(Irrigation) Park Dedication A 353S- Zi- Trail S 3 S- y Q� Trail Dedication — TOTAL 7 /9 5/.2 .L_ Page 2 of 3 .MCES USE:Letter Reference: 170403E4 Address ID: 710960 Payment ID:400958 Date of Determination: 04/03/17 Determination Expiration:04/03/19 Greetings! Please see the determination below. Project Name: Bank of America Project Address: 3385 Central Park Village Drive Suite#/Campus: Building K/Central Park Commons City Name: Eagan Applicant: Daniel Savage, Nationwide Permitting Services Special Notes: None Charge Calculation: Office: 2279 sq.ft. @ 2400 sq.ft./SAC=0.95 Total Charge: 0.95 Credit Calculation: Central Park Commons (SAC 07/16)—3325 Central Park Village Drive Retail: 3425 sq.ft. @ 3000 sq.ft./SAC= 1.14 Total Credit: 1.14 Net SAC: -0.19 —or— 0 SAC Due The business information was provided to MCES by the applicant at this time. It is the City's responsibility to substantiate the business use and size at the time of the final inspection. If there is a change in use or size, a redetermination will need to be made. If you have any questions email me at:cory.mccullough@metc.state.mn.us. Thank you, Cory McCullough SAC Technician Please visit our SAC website by going to: http://www.metrocouncil.org/SACprogram 3'd0 Robert Street North I 21 "'U!I. t1 551:,' I Phor:e 651 631.1000 I Fa,b511550 ! m 651.201.0004 I motrocounci!.crc METROPOLITAN Err,r?io,, C O U N C I L 1 U o. L i �!eIl ) 6 k /EM ','. c4-5, el 1,ii ,,. i 1 .1 1 I Iiii► /ill - c.i 1 . g1 i(j 1 Q S �C`,FIB ill!! t zQ • .7.,1,.di 4 . I I I f f( A „ .I-H 71 I till HAU /- A 1i11I 1 i -l• MiD: w, , 1I I R 1 --0- I I i IL.I F __ A_� I .9-.2 j , 4A �I.� E 8 r ' 1 _1 _. lis8 � •$ lh!-P I,-.1 t t I. f/I rig 1 ii E QE, .7,/I o1-AI A-A 1A-0 A-A Alt a-AI A- I Aif-Al EA R i t t t Ill F/I 9-A I� I I F- -v- 2 e! gg !IMMIXz�eEIMIIL �E' EI' ¢n t:► W gls 'i ii1§1 ��11 A-z1 x ICn zi _ i� s'Ia9 I,, not , 1 a A-/II AI s ,y1 kq $ lt 0-- - , L .,- Q ,-,r. 1 - ; i 11;R h,,; , ) n S/I, ± l'-A...I_r .J,I.„. D.6 t I .z/1 t-.0 r (l'' ,4) / `_� s �fi-i\' ((' I l� -- — SIL .E I G 'z R i xi.:_} -rias-dt °e 1d 2.-.,k .z is-e .iI -r S 38 f...S rr 0LxI/!ilnli,l mil r I I 1ss x aI �Ia I ! '■ ill `I Ili r I 8. �w I' Opel b. t v IlIetrF t ..t o s r m g ;1 if 111E1 � I ®_ !• _ 1� - ° I ° 4 �a sib It 11 W/p tz sf; it .o- � ( I -1_ a. cIff $ 'C® ®�90 I _ . ALJ (. 1 `bil8 X7_`1. S @ 81.18 1E' f gE gE -dl .-_ '_.-`.''� e s .,../,,,,z1 I�- I t I� a ' JI r11 I h z-m z/I-OI zh t-.o ;-A.._ .s a —I k '� '� gyq� � I CE'�I j 61'1 '05C y':Y` I 7, ” 4 1 n R ���: — --- 00 0 0 0 0 0 L__ I — I- — I �CE —i4Et GE �-- I a i g 1 -! j/It-A A-A I A-A I(iIc- A-A NI 0,9 A-A 4.VIFA4 A-A ' -- ill.1 gi 1 a I I A/101-AS T I I I IS Eii G F p s 5 F/1 a-A i 0o b b b 1 ° -Hb 0 b 4 : � a gg1 ILI ti °egg 1 effi i; Y 000 00000000 O 00000 a > m 73 Z // N � { r" ° 0 W0 = m C "Px cn 1 m z 2 2 Ci? co -o m z m Z I n 0 , ov53 zer--( / �� — — ifi T co M I. - I W � nm � � - - -- - z I in m r� v) �NE E 1 g co0 (n X o a 7X0 z / r w Z a) X / cco n o — -6 rn 3 w m IV n = 9 >i'. a (1) x rri CMP xD m O 1I \I 1 i N 73 . , w g 0, G1 cQ 0— _,. ,-1-----1 q , v n < \ DRio ' i1is•x=zN ? 9 ISamp6 — nimi 0.. X xj / / o�,m co co e / \ N,„Z I D Z _ (iiii N D Z ,c, 0 C N m (-------- N ? MI A Special Inspection Final Report Bank of America—Central Park Commons Eagan 3385 Central Park Village drive Eagan, MN 55122 Prepared for Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 BRAUNBraun Intertec Corporation I NTE RTEC The Sc:ierce Ycn Build On. BRAUN Braun Intertec Corporation Phone:952.995.2000 11001 Hampshire Avenue S Fax:952.995.2020 INTERTEC Minneapolis,MN 55438 Web:braunintertec.com The Science You Build On. November 3, 2017 Project B1704848 Mr.Adam Stribling Jones Lang LaSalle Americas, Inc. 135 S LaSalle Chicago, IL 60603 Re: A Special Inspection Procedural and Final Report Submittal Bank of America—Central Park Commons Eagan 3385 Central Park Village Drive Eagan, Minnesota Dear Mr.Stribling: This report details the procedures used in our evaluation and the conclusions related to the special inspection requirements detailed in the Special Structural Testing and Inspection Program Summary Agreement for the Bank of America—Central Park Commons Eagan.Also included are the supporting Special Inspection Daily Reports. Special Inspection and Testing Procedures Special inspection services were provided by International Code Council(ICC)certified special inspectors in accordance with our contract and the project documents which include referenced State Building Code, including adopted portions of Chapter 17 International Building Code(IBC),the project special inspection schedule and the project plans and specifications. The purpose of special inspections is to provide a review of the contractor's work designated by the design professionals or the code official as needing special inspection under the guidelines of the State Building Code to determine compliance with the approved construction documents.The special inspector does not have the responsibility or authority to, nor is it the intent of special inspections to have them,judge or modify construction documents.Only the engineer-of-record or the architect-of- record can do so. As the special inspections were completed,a Special Inspection Daily Report was prepared to summarize the results of the inspections and testing. Daily reports were distributed periodically as they were prepared.As part of this report, items needing correction or discrepancies observed from the approved construction documents are noted. AA/EOi Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 Page 2 Project Documents The project documents that were provided to us were used as the basis of our inspections.When we received approved plan modifications,the modifications were also used to evaluate work completed. Soils Basis for Soils Observations A geotechnical evaluation was performed for this project by Braun Intertec Corporation under project number B1501149,dated June 25,2015. In this evaluation,soil borings were performed to evaluate the subgrade conditions.The soil borings primarily encountered fill consisting of sandy lean clay and silty sand soils over native poorly graded sand alluvium in the area where the Bank of America is located.The recommendations of the report were completed during the mass grading of the site and"A Summary Report of Site Grading and Statement of Building Pad Certification"was completed by Braun Intertec under project number B1501149.00,dated November 3,2016. As excavations for the building occurred,we noted that the soils encountered were silty sand,fine to medium grained with gravel, brown to gray,very dense.The soils that were encountered were consistent with the Summary Report of Site Grading and Statement of Building Pad Certification. Soil Testing Procedures Soils exposed in the bottoms of the excavations were visually evaluated,while those at depth were evaluated using hand auger borings.These procedures were performed to determine if the observed and tested soils were consistent with those encountered by the geotechnical evaluation and suitable for support of the design structural loads. Hand auger borings were drilled with a 1 1/2-inch-diameter hand auger,and were advanced in 2-to 4-inch increments to depths of 2 to 4 feet below the bottom of the excavation.The auger was then withdrawn from the borehole to obtain cuttings.Soils encountered in the borings were classified in general accordance with ASTM D 2488, "Description and Identification of Soils(Visual/Manual Procedures)." Preliminary estimates of soil consistency and density were also evaluated based on resistance to penetration of the hand auger and the turning resistance. BRAUN INTERTEC Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 Page 3 After review of the subgrade,additional fill was placed to achieve design elevations of the bottom of foundations and slabs.We tested compaction of the fill by the Nuclear Moisture Density Method (ASTM D 6938)which determines in place density,to evaluate soil compaction by comparing to the results obtained in laboratory Proctor test results.The test results were distributed under separate cover as they became available. In addition to evaluating relative density and moisture content of the fill,we also observed that the soil classification of the fill was consistent with the requirements of the project documents. Soils Conclusions The required testing in the field and laboratory has been completed.Observations and testing of the excavation bottoms indicated that the exposed soils were consistent with those encountered by the geotechnical evaluation and building pad certification performed for this project.Compaction testing done during placement of backfill and additional required fill indicated the procedures used by the contractor were adequate to compact the backfill and fill in accordance with the project requirements. From our evaluation, it is our opinion that the foundation subgrades are capable of supporting a net allowable bearing pressure of up to 3,000 pounds per square foot,and meet performance expectations stated in the geotechnical evaluation.There are currently no outstanding or unresolved soils-related issues. Cast-in-Place Concrete Construction Concrete Reinforcement We reviewed the reinforcement requirements on the project structural drawings.We reviewed steel grade,size, length,spacing, location, and splice lengths to evaluate if in-place reinforcement was placed in accordance with the requirements of project plans and specifications.We also noted if in-place reinforcement was free of excessive rust and soil. In addition to observing concrete reinforcement,we reviewed other structural anchors cast into the concrete. We noted that shape and dimensions of the concrete formwork was as noted in the plans and specifications. Concrete Placement Observations The special inspector reviewed the mix designation shown on the concrete delivery ticket to document the specified concrete was being placed for the element being placed and that the mix was placed within the specified time limits. During placement of concrete,the inspector also noted any displacement of the reinforcement or other items within the member being placed. If found,the contractor was advised to reposition the items to their original locations.Observations were performed to monitor the procedures used by the contractor to place and consolidate concrete were consistent with requirements of the plans and specifications and typical industry standards. BRAUN INTERTEC Jones Lang LaSalle Americas, Inc. Project 61704848 November 3,2017 Page 4 Concrete Testing The special inspector observed or performed testing to measure the plastic concrete's slump, temperature and air content during each placement based on the project documents. In addition, concrete cylinders were cast to evaluate the concrete's compressive strength. Concrete cylinders were temporarily stored at the site,then transported to our laboratory for curing and compressive strength testing. Results of the concrete compressive strength testing were distributed as they became available to parties who requested them. Cast-in-Place Concrete Construction Conclusions Reinforcement placement detailed in the attached Special Inspection Daily Reports was observed according to the requirements of project plans and specifications.There are currently no outstanding or unresolved reinforcing steel-related issues. Concrete was placed and cured in a manner consistent with the project documents and industry standards. Required testing in the field and in the laboratory has been completed and found acceptable. Compressive strength testing indicates the concrete placed meets project requirements.There are currently no outstanding or unresolved cast-in-place concrete construction-related issues. Structural Steel Construction Welding Visual Field-Made Weld Observations Visual examination of the field-made welded connections was conducted in accordance with the requirements of AISC 360,Chapter N,Section 5.4,the current AWS D1.1,and project plans and specifications. Welding Conclusions Field-made welded connections detailed in the attached Special Inspection Daily Reports were observed in general accordance with the requirements of the project plans and specifications.The connections were found acceptable following the change in detail provided by the project structural engineer.There are currently no outstanding or unresolved structural field-made welding-related issues. BRAUN I NTERTEC Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 Page 5 Bolting Column Anchor Bolts Column anchor bolts were observed to document they were in place and that nuts were installed,fully engaged,and snug tight.The base plates were observed to document they were in full contact with the adjoining surface. Tension-Control Bolted Connection Tension-control bolted connection observations were conducted in general accordance with the AISC 360,Chapter N,Section 5.6.We observed and documented that bolt holes were filled,correct bolts were used, nuts were fully engaged,and the splined end of the tension-control bolts had separated from the body of the bolt. Removal of the splined end is a direct indicator the bolt has been torqued to the minimum snap-off load. In addition,each connection was observed for fit-up and to determine if the various plies were in contact with one another. Bolting Conclusions Bolted and anchor bolt connections detailed in the attached Special Inspection Daily Reports were observed in general accordance with the requirements of the plans and specifications.There are currently no outstanding or unresolved bolting-related issues. Metal Deck Metal Deck Weld and Fastener Observations Metal deck weld observations were conducted in general accordance with the requirements of AISC 360, Chapter N,Section 6,the current AWS D1.3,and project plans and specifications. Items reviewed included the quality,size,and spacing of the welds. In addition,the location and completeness of the side lap fastener installation were observed and evaluated. Metal Deck Conclusions Metal deck welding,and side-lap fasteners detailed in the attached Special Inspection Daily Reports were observed in general accordance with the requirements of the project plans and specifications.There are currently no outstanding or unresolved decking-related issues. BRAUN INTERTEC e Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 Page 6 Sprayed Fire-Resistant Materials Sprayed Fire-Resistant Material Procedures Spray-applied fire-resistant material was observed and tested in accordance with requirements of the project specifications and applicable test methods. Fireproofing thickness requirements for the Cafco 300AC were provided to us by the fireproofing contractor, Floor Technology. Prior to the application of fireproofing material,substrate members were observed for surface cleanliness.After fireproofing material was applied, random locations were selected for thickness,as well as density and bond testing which were tested according to the requirements of the project specifications and ASTM E 605 and ASTM E 736. Sprayed Fire-Resistant Material Testing Results Fireproofing thicknesses observed at random locations meet the requirements of the submittals provided to us by the contractor. We performed 2 bond tests at random locations and testing results were 195 and 225 pounds per square foot(psf). Individual results and the overall project average meet the project requirement of a cohesion/adhesion strength of at least 150 psf. We performed 2 density tests in accordance with the requirements of the project specifications. Individual results were 23 and 25 pounds per cubic foot(pcf). Individual density results and the overall project average density meet the project requirement of 15 pounds per cubic foot. Sprayed Fire-Resistant Materials Conclusions Surface condition of members to be fireproofed detailed in the attached Special Inspection Daily Reports were observed and found to meet requirements of the project specifications. Individual thickness readings and the overall average for the various elements meet the minimum thickness requirements. Results of the density and bond testing meet the requirements.There are currently no outstanding or unresolved sprayed fire-resistant materials-related issues. Conclusion Based upon the inspections conducted,the testing performed,the attached Special Inspection Daily Reports and the reports referenced herein, it is our professional judgment that,to the best of our knowledge,the inspected work was performed and completed in accordance with the approved plans, specifications, architect and structural engineer provided modifications and applicable workmanship provisions of the State Building Code and the International Building Code. BRAUN INTERTEC Jones Lang LaSalle Americas, Inc. Project B1704848 November 3,2017 Page 7 General Thank you for the opportunity to provide the special inspection and testing services for this project.After review of this Special Inspection Final Report, if you have any questions or require additional information,please call Brandon Rounsville at 612.221.9007(brounsville@braunintertec.com)or Gregg Jandro at 952.995.2270(gjandro@braunintertec.com). Sincerely, BRAUN INTERTEC CORPORATION —u �rendorS. Rounsville, E T Staff Engineer Inspecting Firm:Braun Intertec Corporation I hereby certify that this plan,specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. ,,atq�.°C, 1 ,s,y¢ry R.Jancy PG r ' ` , ;) Vice President—Principal Engineer t " License Number: 18221y`'•. ir '' 'fiNovember 3, 2017 V,,O �1 ..'1* h,r ra1>`�`.� etieeee Attachments: Special Inspection Daily Reports 1 through 6 Structural Steel Special Inspection Daily Reports 1 through 3 Fireproofing Special Inspection Daily Reports 1 through 2 c: Mike Grannes,City of Eagan Nelda Molini,Architectural Design Collaborative Harold Higgenbotham, Harold G. Higgenbotham,P.E. Bert Westerman,Gardner Builders, LLC John McNamara,Gardner Builders, LLC Sam Johnson,Gardner Builders, LLC Terry Mechelke,Gardner Builders, LLC BRAUN INTERTEC �PY Special Structural Testing & Inspection Program Summary Schedule Project Name EAGAN-Bank of America Project# Location 3385 Central Park Village Drive. Eagan,MN 56122 Permit# (1) • Technical(2) Description(3) Type of Specific Report Section Article Inspection(4) Frequency(6) Assigned Firm{6) . 1705 1706.2 Steel Construction SiS Per nspeotion Braun Intertec 1705 1 1705.3 Concrete Construction SIS Per Inspection Braun Intertec 1705 1705.4 Masonry Construction SIS Weekly Braun Intertec 1705 1705.6 sons SIT Weekly Braun Intertec i r r i Note:This schedule shall be filled out and included in a Special Structural Testing and Inspection Program. (if not otherwise specified, assumed program will be "Guidelines for Special Inspection & Testing" as contained in the State Building Code and as modified by the State adopted IBC. *A complete speclfficatlon-ready program can be downloaded directly by visiting CASE/MN at www.cecm.org. 1. Permit number to be provide by the Building Official 2. Referenced to the specific technical scope section in the program 3. Use descriptions per IBC Chapter 17,as adopted by MN State Building Code. 4. Special Inspector-Technical(SIT);Special Inspector-Structural(SIB) 5. Weekly,monthly,per test/inspection,per floor.etc. 6. Name of firm contracted to perform services Acknowledgements (Each appro date representative shall sign below) Owner/th.4(+ll SIR p$wpae, ; � � Firm ��j..f' Date IIi,('7 1 Contractor Bert Westerman , '1.]''''. "-±s-1--- — FirmDate 5-1-17 Gardner Builders Architect Re mundo Feito 111, Firm ADC Date 05/01/2017 SER Harold Higgenbotham /' Firm Harold G.Higgenbotham,P.E. Date 112017 SI- .,.,� Tom-..,Ice Firm ,�f�e.M /�, �, 1�/u� -�/�`.t'�T�'l` at? D&te � TA _.di -,..f Firm3I4rN n Ne Cafe. Date /� (rf F Firm Date if requested by Engineer/Architect of Record or Building Official,the individual names of all prospective Special Inspectors and the work they intend to observe shall be identified as an attachment. Legend. SER=Structural Engineer of Record SI-T-Special inspector-Technical TA In Testing F=Fabricator SI-S=Special Inspector-Structural Agency Accepted for the Building Division By Date BCSD-PRO19 4/03 Special Inspector Final Report Date: To City or County of: Attention: Street Address: City: State: Zip Code: RE: Final Project Report • Project Name: EAGAN-Bank of America Address: 3385 Central Park Village Drive,Eagan, MN 55122 To Whom it May Concern: This is to certify that I performed special inspections on the following portions of the work at the above address which required continuous inspection,and which I was employed to inspect: • Based on my personal observation and written reports of this work, It is my judgment that the inspected work was performed, to the best of my knowledge, in accordance with the approved plans, specifications, and the applicable workmanship provisions of the Uniform Building Code. Sincerely, Special Inspector's Signature Date Print full name ID Number cc: Client/Owner Architect/Engineer City of EaQafl meso # 39 TO: Jill Hutmacher, Community Development o Mike Ridley, Planning Darrin Bramwell, Fire Marshal Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering o Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance e Jared Flewellen, Parks&Recreation Jon Eaton, Utilities a Josh Wilske, IT o Eric Macbeth, Maintenance e Gregg Hove, Maintenance - Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments: Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes 0 No Landscape Security Required Zoning: ❑ Yes 0 No Water Quality Dedication Meter Size: O Yes 0 No Park Dedication O Yes 0 No Trail Dedication O Yes ❑ No Tree Dedication ❑ Yes ❑ No PRV Required O Yes 0 No REF Reconciliation between Engineering & Finance ❑ Yes 0 No Street/Curb Cut Required O Yes 0 No Stormwater performance security required Signature Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters 4011° City of EaQau Memo # 39 TO: Jill Hutmacher, Community Development Mike Ridley, Planning Darrin Bramwell, Fire Marshal Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance Jared Flewellen, Parks&Recreation Jon Eaton, Utilities Josh Wilske, IT Eric Macbeth, Maintenance Gregg Hove, Maintenance Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments: Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes 0 No Landscape Security Required Zoning: ❑ Yes El No Water Quality Dedication Meter Size: ❑ Yes 0 No Park Dedication ❑ Yes 0 No Trail Dedication ❑ Yes 0 No Tree Dedication ❑ Yes 0 No PRV Required ❑ Yes 0 No REF Reconciliation between Engineering & Finance ❑ Yes 0 No Street/Curb Cut Required ❑ Yes 0 No Stormwater performance security required Eric Macbeth 4/4/2017 Signature Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters 411° City of EaQan Memo # 39 TO: Jill Hutmacher, Community Development Mike Ridley, Planning Darrin Bramwell, Fire Marshal Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance Jared Flewellen, Parks&Recreation Jon Eaton, Utilities Josh Wilske, IT Eric Macbeth, Maintenance Gregg Hove, Maintenance Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments: Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes 0 No Landscape Security Required Zoning: ❑ Yes 0 No Water Quality Dedication Meter Size: ❑ Yes 0 No Park Dedication ❑ Yes ❑ No Trail Dedication ❑ Yes 0 No Tree Dedication O Yes 0 No PRV Required O Yes 0 No REF Reconciliation between Engineering & Finance ❑ Yes 0 No Street/Curb Cut Required ❑ Yes 0 No Stormwater performance security required 7044./ate 4/4/17 Signature Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters 411111* City of Eaaafl Mem # 39 TO: Jill Hutmacher, Community Development Mike Ridley, Plannin rrin r mwell Fire Marsha Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance Jared Flewellen, Parks&Recreation Jon Eaton, Utilities Josh Wilske, IT Eric Macbeth, Maintenance Gregg Hove, Maintenance Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments: Aiare Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes D No Landscape Security Required Zoning: ❑ Yes 0 No Water Quality Dedication Meter Size: ❑ Yes 0 No Park Dedication ❑ Yes 0 No Trail Dedication ❑ Yes 0 No Tree Dedication ❑ Yes 0 No PRV Required ❑ Yes 0 No REF Reconciliation between Engineering&Finance ❑ Yes 0 No Street/Curb Cut Required Yes 0 No Stormwater performance security required IH '-17 Signature Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters ,, Cid f E an Mento # 39 TO: Jill Hutmacher, Community Development Mike Ridley, Planning Darrin Bramwell, Fire Marshal Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance Jared Flewellen, Parks& Recreation Jon Eaton, Utilities Josh Wilske, IT Eric Macbeth, Maintenance Gregg Hove, Maintenance Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments:at✓� l�✓� ZZC G.}'J , L'ievzia,.( afa G--aFc Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes Landscape Security Required Zoning: PD ❑ Lld Yes 'No Water Quality Dedication Meter Size: 10 Yes ❑ No Park Dedication e3535, 3 y (t93 9//000 q @ Alb S.r.-f) El Yes �o Trail Dedication El Yes I NO Tree Dedication ❑ Yes ❑ No PRV Required ❑ Yes ❑ No REF Reconciliation between Engineering & Finance ❑ Yes ❑ No Street/Curb Cut Required ❑ Yes ❑ No Stormwat performance security required `// 2 0 7 Signature Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters IA B LA,- 1 ct t ppkt.iii?)aik., \ \ L„,.....,.... , , ., L5) \. , „, \ \x , \ ., ., t,.,,. \ ,. 0 \ ( UH ) i ''"" "l'INft. \ : ... .4 i OP* q _ (1 ) 3” SLEEVE ¢ BE rlysol! C a PVC a - ,ATE 4-TY Q.alk,,\$/ss\111/41\_ fi- „..04$1*Irefl td)14,,fii" ......0 1 \ ' 4 4 ,,," _.4........ _ ,,,k„„i _.,,,,,;;;I-eork 411111„ _Airctoks, ....\\ _.,0,,,..7.2...., '4 .„..„,...\ q 4 q , Al*Otfrg I k.1 114. 1k \'%.,, \\ N . N •4 \ Ito* I\ ",.:\\ ' V 1 I :le, 01110 t 11 -PI' /' 0‘ I r IP it VII?V \\,* X 0,0) , \ '''ff\ A alt L J t -\<' 4-GU < .,%'` Wilk\ ‘ W 0 0 Ti \ *0 (1 Yalli\te,„A 4C1 Skftil-',14\vio'•"" 0-\ -:<,,;‘,, ,'\ A,‘ .04% .„ 't.4;,:iii,,\O --. iiiiiii4r,:k-•-6,\--. \ i ,..... Ze\ 1 ..-\ --;- , \ 1),i, ) - ' 1.,;:fei,,V / '`'''. — 4:, % liA,er '''A \‘‘W-,4(9h,;,"'t/ _______X_____G W./A l ) ,c\tv lity;9 :i,\ iik<f trilli. , 1 ''"i'l I.\ C 0j...--r-o/firyoiy,71,/,,:t,4-4- .‘.,:.yg ittfite. ,\ •-\.,,,,,,4..fro 1., 1 P.- / i,r.61W, / \ '.4./''.14147:-kloill / / 0 /NVAA / '0,1.'l,,,t4••? / ' $ 4/14V / \, \ `V'" / / ; : � / / I / i ;I / / I I I //, : . City of Eaafl MeMo # 39 TO: Jill Hutmacher, Community Development Mike Ridley, Planning Darrin Bramwell, Fire Marshal Scott Peterson, Building Inspections Russ Matthys, Engineering John Gorder, Engineering Aaron Nelson, Engineering Dave Westermayer, Engineering Leon Weiland, Engineering Joe Gibbs, Finance Jared Flewellen, Parks&Recreation Jon Eaton, Utilities Josh Wilske, IT Eric Macbeth, Maintenance Gregg Hove, Maintenance Lt. Mike Fineran, Police FROM: Mike Grannes Inspector Remarks: P1 building in Central Park Village Date: 04/04/17 Project Name: Bank of America Sub Type,Work Type: New building Address: 3385 Central Park Village Drive The plans are located in the Plan Review area in Community Development. Please review and indicate any concerns you have with these plans and resolve these issues with the affected parties. If you are requesting that issuance of the building permit be held, please submit the proper"hold request"form. Please submit a response within 7 days. Comments: A....\ 5 „_,...,,,„-L._ �,-�-x� d.._ s s s Q-��, �rJ�aS k....,-14,-,--e-- c o�St`�. �t Indicate below any fees that are to be collected with the building permit. Amount ❑ Yes ❑ No Landscape Security Required Zoning: LI Yes in No Water Quality Dedication Meter Size: ❑ Yes ❑ No Park Dedication ❑ Yes ❑ No Trail Dedication ❑ Yes ❑ No Tree Dedication ❑ Yes 0. No PRV Required 1I Yes ❑ No REF Reconciliation between Engineering& Finance ❑ Yes 5i No Street/Curb Cut Required ❑ s D, No Stormwater performance security required i / S l31(-7SI nat re g Date G:\Building Inspections\FORMS\Commercial Bldgs Final&Plan Review Letters 4 1 0 I I I I I I I 11'-' City of Eaaari April 25th2017 Raymundo Fieto 945 North Pennsylvania Ave Winter Park, FL 32789 Re: Bank of America 3385 Central Park Village Drive Dear Mr. or Mrs. Molina; We have started our review of the construction documents submitted in pursuit of obtaining a building permit for the above referenced project. This review is not intended to be an exhaustive and comprehensive report and is limited to the plans that were supplied to the City of Eagan. Unless otherwise noted, all references are to the 2015 Minnesota Building Code(MNBC)which has adopted, with amendments,the 2012 International Building Code as well as the 2015 Minnesota Accessibility Code(MNAC). It is our goal that this review will help you in complying with the applicable codes and we are, therefore, requesting that the following items be addressed: / / v4. Provide contractor information. Only (1) copy of the energy compliance forms was provided. Please provide another set. Change the International Plumbing Code designation, under the applicable plumbing codes,to the // 2015 Minnesota Plumbing code. kii . Change the fire code, under the applicable fire code,to be the 2015 Minnesota Fire Code. . What is door 100A being used for? 6. Provide a statement of special inspections as required by MNBC section 1704.3. ,Jl../ What is a"bandit barrier" as referenced in A04.01? :i. . Provide finish classifications as required by MNBC section 803.9. Page A08.01 elevation detail B shows the lavatory sink and soap dispenser within the 5 foot clearance for the water closet. Provide two sets of the above referenced plans to the building inspection department for further review. If you have any questions concerning this letter, please contact me at(651)675-5676 Monday through Friday 8:00 am to 4:30 pm or email me at mgrannes@citvofeagan.com. Sincerely,'r Mike Grannes 416° City of Eaaall Senior Building Inspector Cc: Dale Schoeppner, Building Official IP • • CityEaaanof Project: 6.k. a. Q,v.u,-cc. Date: (//i17-) Checklist to obtain a FOUNDATION Permit: Date Received O Certificate of Survey o 3/4;47 2 Sets of Structural Plans o 3/Vi/I 7 2 Sets of Civil Plans (i.e. site, grading, erosion, utility) o 3/2iii 17 1 Code Analysis O 3I2 1/1 1 Soils Report 6 //3/,7 1 MCIWC SAC Determination o /ZYA 1 Set Project Specifications b 5317 1 Special Structural Testing & Inspection Program Summary Schedule Checklist to obtain a BUILDING Permit: Date Received o 7hy/7 2 Sets of Architectural Plans • 3/2V/7 2 Sets of Landscaping Plans o 5/317 1 Set of Energy Compliance Forms 3A0 3 sti- - Building Envelope - HVAC - Service Water Heating - Power& Lighting O 3/2Y, 17 1 Emergency Response Site Plan Fire Stopping Submittals Fire Protection System Plan Review Information Sound Attenuation Requirements *Mechanical, Electrical and Sprinkler plans are usually submitted prior to commencing (i.e. on a "design- build" basis) ifilft COMcheck Software Version 4.0.5.1 Envelope Compliance Certificate Project Information CITY CO P Y Energy Code: 2015 IECC Received Title: Bank of America Eagan New Store Location: Eagan, Minnesota R AL ry ���� Climate Zone: 6a MAR Project Type: New Construction Vertical Glazing/Wall Area: 14% Construction Site: Owner/Agent: Designer/Contractor: 3385 Central Park Village Drive Bank of America Luis O. Perez Eagan, MN 55122 P&G Engineering Design 21 SW 102 CT Miami, FL 33174 (786)863-7091 Iperez@pgengineeringdesign.com Building Area Floor Area 1-Office : Nonresidential 3394 Additional Efficiency Package Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factorial Perimeter Roof: Insulation Entirely Above Deck,[Bldg.Use 1 -Office] 3684 --- 30.0 0.032 0.032 Floor:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 -Office](c) 253 --- 10.0 0.480 0.540 NORTH Exterior Wall North West:Steel-Framed, 16"o.c.,[Bldg.Use 1 -Office] 935 19.0 8.0 0.058 0.064 Storefront:Metal Frame Curtain Wall/Storefront,Perf.Specs.:Product 175 --- --- 0.260 0.360 ID PPG Industries Solarban 60(2)Clear+Clear,SHGC 0.38,PF 0.18, [Bldg. Use 1 -Office](b) Windows:Metal Frame with Thermal Break,Perf.Specs.:Product ID 81 --- --- 0.260 0.360 PPG Industries Solarban,SHGC 0.38,PF 0.57,[Bldg.Use 1 - Office](b) EAST Exterior Wall North East:Steel-Framed, 16"o.c.,[Bldg.Use 1 -Office] 963 19.0 8.0 0.058 0.064 Windows:Metal Frame with Thermal Break,Pert Specs.:Product ID 27 --- --- 0.260 0.360 PPG Industries Solarban,SHGC 0.38,PF 0.35,[Bldg.Use 1 - Office](b) SOUTH Exterior Wall South East:Steel-Framed,16"o.c.,[Bldg. Use 1 -Office] 935 19.0 8.0 0.058 0.064 Windows:Metal Frame with Thermal Break,Perf.Specs.:Product ID 67 --- --- 0.260 0.360 PPG Industries Solarban,SHGC 0.38,PF 5.00,[Bldg.Use 1 - Office](b) Door:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Office] 24 --- --- 0.500 0.500 Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 1 of 25 Egan Central Park 2015.cck Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factorial Perimeter WEST Exterior Wall South West:Steel-Framed, 16"o.c.,[Bldg.Use 1 -Office] 963 19.0 8.0 0.058 0.064 Windows:Metal Frame with Thermal Break, Perf.Specs.:Product ID 133 --- --- 0.260 0.360 PPG Industries Solarban,SHGC 0.38,PF 0.38,[Bldg.Use 1 - Office](b) Windows:Metal Frame with Thermal Break,Perf.Specs.:Product ID 67 --- --- 0.260 0.360 PPG Industries Solarban,SHGC 0.38,PF 0.30,[Bldg.Use 1 - Office](b) (a) Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Enveloire \ASSES Pósign j$%better than code \\ Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been • designed to meet the 2015 IECC requirements in COMcheck V ,ramnenf�}„ .1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. i, Luis 0. Perez, PE �, - 03/14/2017 Name-Title 3 ignai+tfre / Date A .„ % m,F0F M S$'�` m...auxumma ` Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 2 of 25 Egan Central Park 2015.cck Intl' COMcheck Software Version 4.0.5.1 Afil Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Bank of America Eagan New Store Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 3385 Central Park Village Drive Bank of America Luis O. Perez Eagan, MN 55122 P&G Engineering Design 21 SW 102 CT Additional Efficiency Package Miami, FL 33174 (786)863-7091 Iperez@pgengineeringdesign.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Bank(Bank:Banking Activity Area) 3684 0.91 3352 Total Allowed Watts= 3352 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Bank(Bank:Banking Activity Area) LED:B&BE:LED PAR 13W: 1 32 13 416 LED:C:LED PAR 20W: 1 2 30 60 LED:C1:LED PAR 13W: 1 7 13 91 Linear Fluorescent:D:48"T8 28W(Super T8):Electronic: 1 3 25 75 Linear Fluorescent:Dl:24"T8 17W:Electronic: 1 2 19 38 LED:E:LED Panel 44W: 1 11 44 484 LED:E1A:LED Panel 40W: 1 6 40 240 LED:H1:LED Linear 33W: 1 35 44 1540 LED:M:LED Panel 40W: 1 3 40 120 Total Proposed Watts= 3064 interior Lighting PASSES:°Design 9%better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 3 of 25 Egan Central Park 2015.cck ` `"`po►M►nmm�xu►unnngi, , Luis 0. Perez, PE ��o°'• \S �...•iiiA�S ��, 03/14/2017 Name-Title Si,,- ature itf: Date 714L V. F� iq ..'--1.......-*".. C30,`,,,,. S% FOF MINKS �n��Nnnunmm�mn►►►►"""�`,,` Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 4 of 25 Egan Central Park 2015.cck isil COMcheck Software Version 4.0.5.1 1( Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Bank of America Eagan New Store Project Type: New Construction Exterior Lighting Zone 2(Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor: 3385 Central Park Village Drive Bank of America Luis O. Perez Eagan, MN 55122 P& G Engineering Design 21 SW 102 CT Miami, FL 33174 (786)863-7091 Iperez@pgengineeringdesign.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Drive Thru(ATM/Night depository location)(c) 2 machines 90 No 360 Bank Exterior Hallway(Walkway<10 feet wide) 146 ft of 0.7 Yes 102 Driveway 11646 ft2 0.06 Yes 699 Total Tradable Watts(a)= 801 Total Allowed Watts= 1161 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. (c)ATM/Night depository sites have a base allowance of 180 W per site. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Drive Thru (ATM/Night depository location 2 machines): Non-tradable Wattage Lamp Type 5SR:5S:LED Panel 44W: 1 18 46 828 Bank Exterior Hallway(Walkway< 10 feet wide 146 ft of walkway length): Tradable Wattage Lamp Type KR6:K6:LED A Lamp 25W: 1 12 30 360 Driveway(11646 ft2):Tradable Wattage Lamp 2M-E:2M-E:LED Roadway-Parking Unit 88W: 1 1 90 90 Lamp 3M-E:3M-E:LED Roadway-Parking Unit 88W: 1 1 90 90 Lamp 5S-E:5S-E:LED Roadway-Parking Unit 130W: 1 1 133 133 Total Tradable Proposed Watts= 673 Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 5 of 25 Egan Central Park 2015.cck �-E'',list iF�\Lighting c aas \\a��a� £ M\ as � �. ti PASSES: 1{� tae ., , '---',1'.- .. � Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck VersiQuAlli u� and to comply with any applicable mandatory requirements listed in the Inspection Checklist. `,``` u��tp� i„�4v, Luis 0. Perez, PE �,o°° \S : PtA04/14/2017 Name-Title ign. rg• /*-.. :�' Date �F:ED P'•ifr `,,I ,,L a I r A f, 3 • e S t . ,,..00( i e9 0FMINN‘• 444,,,n, m...000 . • Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 6 of 25 Egan Central Park 2015.cck COMcheck Software Version 4.0.5.1 ril Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Bank of America Eagan New Store Location: Eagan, Minnesota Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 3385 Central Park Village Drive Bank of America Luis O. Perez Eagan, MN 55122 P&G Engineering Design 21 SW 102 CT Additional Efficiency Package Miami, FL 33174 (786)863-7091 Iperez@pgengineeringdesign.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 AHU-1 (Single Zone): Split System Heat Pump Heating Mode:Capacity=17 kBtu/h, Proposed Efficiency=8.40 HSPF,Required Efficiency=8.20 HSPF Cooling Mode:Capacity=19 kBtu/h, Proposed Efficiency=15.00 SEER,Required Efficiency: 14.00 SEER Fan System: None 1 RTU-1 (Single Zone): Heating: 1 each-Unit Heater,Gas,Capacity=80 kBtu/h Proposed Efficiency=81.00%Ec,Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity=33 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=17.50 SEER,Required Efficiency: 14.00 SEER Fan System: None 1 RTU-2(Single Zone): Heating:1 each-Unit Heater,Gas,Capacity=80 kBtu/h Proposed Efficiency=81.00%Ec,Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity=51 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=17.50 SEER,Required Efficiency: 14.00 SEER Fan System: None 1 RTU-3(Single Zone): Heating:1 each-Unit Heater,Gas,Capacity=80 kBtu/h Proposed Efficiency=81.00%Ec,Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity=37 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=17.50 SEER,Required Efficiency: 14.00 SEER Fan System: None 1 Water Heater: Electric Storage Water Heater,Capacity: 10 gallons w/Heat Trace Tape Installed No minimum efficiency requirement applies Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 7 of 25 Egan Central Park 2015.cck Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. $`"���►n+u►►►nn'nn "�tutuy„,�h Luis 0. Perez, PE o•`°° \S 0 . P A � � 03/14/2017 Name-Title Sign. re\,- . , Date P' • �fr.* r A L r.-: f t 4'1 id' di : 1..4. • teal. 1 -9 ..i . . p� o° FOF MINK% d imnym ins n tiO0`� Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 8 of 25 Egan Central Park 2015.cck COMcheck Software Version 4.0.5.1 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. io Plan Review Complies? I Comments/ASsumptions , Req.ICr C103.2 Plans and/or specifications provide all ❑Complies [PR1]1 information with which compliance ❑Does Not can be determined for the building envelope and document where ❑Not Observable exceptions to the standard are ❑Not Applicable claimed. C103.2 'Plans, specifications, and/or ❑Complies [PR2]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the mechanical systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies [PR3]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the service water heating systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 ,Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be ['Not Observable determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. C103.2 Plans, specifications, and/or ❑Complies [PR8]1 calculations provide all information ❑Does Not with which compliance can be LiNot Observable determined for the exterior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts, transformers and control devices. C402.4.1 The vertical fenestration area <= 30 ❑Complies [PR1O]1 percent of the gross above-grade wall ❑Does Not area. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 9 of 25 Egan Central Park 2015.cck Section # i Plan Review Complies? Comments/Assumptions -, &Req.ID 1 C402.4.1 The skylight area <= 3 percent of the ❑Complies [PR11]' gross roof area. ❑Does Not [Not Observable ❑Not Applicable C406 :Plans, specifications, and/or ❑Complies [PR9]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the additional energy efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2,jMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 10 of 25 Egan Central Park 2015.cck Section 11 # Footing/Foundation Inspection Complies? I Comments/Assumptions St Reg3D C303.2 - Slab edge insulation installed per ❑Complies [FO4]2 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies [FO6]1 damage, sunlight, moisture, wind, ❑Does Not landscaping and equipment ['Not Observable maintenance activities. ❑Not Applicable C4O2.2.5 Slab edge insulation R-value. ❑Complies See the Envelope Assemblies table for values. [FO3]2 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 Radiant heating systems panels ❑Complies See the Envelope Assemblies table for values. [FO12]3 insulated to>=R-3.5 on face opposite ❑Does Not space being heated. ['Not Observable ❑Not Applicable C403.2.4 Snow/ice melting system sensors for ElComplies 5, future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. [Not Observable [FO9]3 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3]Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 11 of 25 Egan Central Park 2015.cck Section I ;I # Framing/Rough-in Inspection Complies? i Comments/Assumptions & Req.ID C303.1.3' Fenestration products rated in ❑Complies [FR12]2 accordance with NFRC. ❑Does Not ❑Not Observable ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies [FR13]1 to performance labels or certificates ❑Does Not provided. ['Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ! ❑Does Not 4 [FR8]1 ❑Not Observable ❑Not Applicable C402.4.41I `U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.1. The building envelope contains a ❑Complies 2.2 continuous air barrier that is sealed in ❑Does Not [FR20]1 an approved manner and average ENot Observable assembly air leakage <= 0.04 cfm/ft2. Air barrier penetrations are sealed in ❑Not Applicable an approved manner. C402.5.2 Factory-built fenestration and doors ❑Complies C492.5.4 are labeled as meeting air leakage ❑Does Not [FR1813 requirements. ❑Not Observable ❑Not Applicable t402.5.7' Vestibules are installed on all building ❑Complies [FR17J entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1High Impact(Tier 1) 2 jMedium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 12 of 25 Egan Central Park 2015.cck • Section E I # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, ;Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404,5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2'' requirements. Refer to section details. [PL'b]3 [Not Observable ❑Not Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the ElDoes Not [PL3]1 recirculating hot-water system or heat trace. ❑Not Observable ❑Not Applicable C404.6.3Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. ❑Not Applicable 0404.6.3 Pumps that circulate water between a ❑Complies fPL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls !❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating cycle. ❑Not Applicable C404.6.3' Pumps that circulate water between a :❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to ❑Not Observable <= 5 minutes after end of heating cycle. ❑Not Applicable 1 High Impact(Tier 1) 2f Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 13 of 25 Egan Central Park 2015.cck • Section # I Plumbing Rough-in inspection Complies? Comments/Assumptions St Req.ID C404.7 Water distribution system that pumps ❑Complies [PL8J3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8J3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8J3 water from a heated-water supply . ❑Does Not pipe back to the heated-water source ❑Not Observable through a cold-water supply pipe is a demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL-813- water from a heated-water supply EDoes Not pipe back to the heated-water source through a cold-water supply pipe is a ['Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source ❑Not Observable through a cold-water supply pipe is a demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 11 I High Impact(Tier 1) 2;Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 14 of 25 Egan Central Park 2015.cck 11 High Impact(Tier 1) 2, Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 15 of 25 Egan Central Park 2015.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions Req.ID C402.2.6 Thermally ineffective panel surfaces of:❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable C402.5.5, Stair and elevator shaft vents have ❑Complies C403.2.4. motorized dampers that automatically ❑Does Not 3 [ME3]3 close. ❑Not Observable ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have'❑Complies C4032.4. motorized dampers that automatically ❑Does Not 3 shut when not in use and meet [ME58]3 maximum leakage rates. Check ❑Not Observable gravity dampers where allowed. ❑Not Applicable C403.2.12:HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan system bhp. ENot Observable ❑Not Applicable C403.2.12 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan system bhp. ❑Not Observable ❑Not Applicable C403.2.12 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 ' fan system motor nameplate hp or fan system bhp. ❑Not Observable ❑Not Applicable C403.2.12!HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan system bhp. ❑Not Observable ❑Not Applicable C403.2:12!Fans have efficiency grade(FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% of maximum total efficiency of the ❑Not Observable fan. ❑Not Applicable C403.2.12 Fans have efficiency grade(FEG) >= '❑Complies .3 67.The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% of maximum total efficiency of the ❑Not Observable fan. ❑Not Applicable C403.2.12 Fans have efficiency grade(FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not {ME117J2 the design point of operation <= 15% of maximum total efficiency of the ❑Not Observable' fan. Observable— Applicable C403.2.12 Fans have efficiency grade (FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% ❑Not Observable of maximum total efficiency of the fan. ❑Not Applicable C403.2.13:Unenclosed spaces that are heated ❑Complies [ME71]2 use only radiant heat. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) %2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 16 of 25 Egan Central Park 2015.cck Section 1 1 # I Mechanical Rough-In Inspection Complies? I Comments/Assumptions & RegID j r 0403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.6. Demand control ventilation provided ❑Complies 1 for spaces >500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ['Not Observable economizer, auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation ❑Complies 2 has automatic contaminant detection ❑Does Not [ME115)3 and capacity to stage or modulate fans to 50%or less of design capacity. ❑Not Observable,__, Applicable C403.2.7 Exhaust air energy recovery on ❑Complies [ME57]1 systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). Observable ❑Not Applicable C403.2.8 !Kitchen exhaust systems comply with :❑Complies [ME116]3 replacement air and conditioned ❑Does Not supply air limitations, and satisfy hood rating requirements and maximum El Not Observable exhaust rate criteria. ❑Not Applicable C403.2.9 HVAC ducts and plenums insulated. ❑Complies [ME60]2 Where ducts or plenums are installed ❑Does Not in or under a slab, verification may need to occur during Foundation ['Not Observable Inspection. ❑Not Applicable C403.2.9 °Ducts and plenums sealed based on ❑Complies [ME1Oj7> static pressure and location. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.9. i Ductwork operating >3 in. water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 [Not Observable ❑Not Applicable C403.4.2. ;Open-or closed circuit cooling towers ;❑Complies 3.2.2 have a separate heat exchanger to ❑Does Not [ME122]3 isolate the cooling tower from the heat pump loop, and heat loss is ❑Not Observable controlled by shutting down the ❑Not Applicable circulation pump on the cooling tower loop. 1 High Impact(Tier 1) *Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 17 of 25 Egan Central Park 2015.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ['Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 - of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ❑Not Observable ❑Not Applicable C408.2.2. +.Air outlets and zone terminal devices ❑Complies 1 have means for air balancing. ❑Does Not [ME53]3 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 LL Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 18 of 25 Egan Central Park 2015.cck Section j # Rough-In Electrical Inspection Complies? I Con#ments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies [EL15]1 reduce the lighting load by at least ❑Does Not 50%. ❑Not Observable ['Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies [EL18]1 required spaces. ['Does Not ❑Not Observable ❑Not Applicable C405.2.1, Independent lighting controls installed ❑Complies C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and [EL23]2 visible to occupants. ['Not Observable ['Not Applicable C405,2.2. Automatic controls to shut off all ['Complies 1 building lighting installed in all ❑Does Not [EL22]2 buildings. ['Not Observable ❑Not Applicable C405.2.3 Daylight zones provided with ['Complies [EL16]2 ; individual controls that control the ❑Does Not lights independent of general area lighting. ❑Not Observable ['Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies C405.2.3. equipped with required lighting ❑Does Not 1, controls. C405.2.3. ['Not Observable 2 ❑Not Applicable [EL20]1 C405.2.3, ;'Enclosed spaces with daylight area ElComplies C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting Not Observable C405.2.3. controls. 3 ❑Not Applicable [EL2111 C405.2.4 Separate lighting control devices for ❑Complies [EL4]1 specific uses installed per approved ['Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.2.4 Additional interior lighting power ['Complies [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and ['Not Observable separated from general lighting. ❑Not Applicable C405.2.5 Automatic lighting controls for exterior ❑Complies [EL25]no° lighting installed.Controls will be ❑Does Not daylight controlled, set based on business operation time-of-day, or ❑Not Observable reduce connected lighting > 30%. ❑Not Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. "❑Does Not ❑Not Observable ['Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 19 of 25 Egan Central Park 2015.cck 1 (High Impact(Tier 1) Medium Impact(Tier 2) 3i Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 20 of 25 Egan Central Park 2015.cck Section # insulation Inspection Complies? CommentslAssumptions & Req.ID C303.1 Roof insulation installed per ❑Complies [IN3]1 :manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed only where the roof slope is <=3 in ❑Not Observable 12. ❑Not Applicable C303.1 Building envelope insulation is labeled ❑Complies [IN10)2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant ['Not Observable data. ❑Not Applicable C303.2 Above-grade wall insulation installed ❑Complies [IN7]1 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303,2,1 !Exterior insulation is protected from ❑Complies [IN14)2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ❑Not Observable `Foundation Inspection. ❑Not Applicable C402.1.3 Non-swinging opaque doors have R- ❑Complies [IN19]3 4.75 insulation. ❑Does Not ❑Not Observable ❑Not Applicable 0402.2.1 Insulation intended to meet the roof ❑Complies [IN17]3 ' insulation requirements cannot be ❑Does Not installed on top of a suspended ceiling. Mark this requirement :Not Observable compliant if insulation is installed ❑Not Applicable accordingly. C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [IN6]1 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.5 'Floor insulation R-value. ❑Complies See the Envelope Assemblies table for values. ❑Does Not ❑Not Observable ❑Not Applicable 0492.2,6 .'Radiant panels and associated ❑Complies [INl8]3 components, designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are ❑Not Observable insulated with a minimum of R-3.5. ❑Not Applicable C402.4.2. Roof R-value. For some ceiling ❑Complies See the Envelope Assemblies table for values. 2 systems, verification may need to ❑Does Not [IN2]1 occur during Framing Inspection. ❑Not Observable ENot Applicable C402.5.1. All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked, gasketed,weather stripped [Not Observable or wrapped with moisture vapor- permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 'High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 21 of 25 Egan Central Park 2015.cck Section # Final Inspection Complies? 1 Comments/Assumptions Req.ID C303.3,? !Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. Not Observable ENot Applicable C303.3, Furnished O&M manuals for HVAC ❑Complies C408.2.5. systems within 90 days of system Does Not 3 acceptance. [F18]3 ❑Not Observable ❑Not Applicable C402.5.3 Where open combustion air ducts ❑Complies [FI51]3 provide combustion air to open ❑Does Not combustion fuel burning appliances, the appliances and combustion air ❑Not Observable opening are located outside the LJ—Not Applicable building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. C402.5.6 Weatherseals installed on all loading ❑Complies [F137]1 dock cargo doors. ❑Does Not ❑Not Observable ❑Not Applicable C402.5.8 Recessed luminaires in thermal ❑Complies [F126)3 envelope to limit infiltration and be IC ❑Does Not rated and labeled. Seal between interior finish and luminaire housing. ['Not Observable ❑Not Applicable 0403 2.2 'HVAC systems and equipment ❑Complies [F127]3 capacity does not exceed calculated ❑Does Not loads. ['Not Observable ❑Not Applicable C403.2.4. ;Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3' Minimum one humidity control device per installed ❑Not Observable 'humidification/dehumidification ❑Not Applicable system. C403,2.4. Heating and cooling to each zone is :❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ❑Not Applicable system. 0403.2,4. Heating and cooling to each zone is ❑Complies 1 = controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ❑Not Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device per installed DNot Observable humidification/dehumidification ❑Not Applicable system. C403.2,4. Heat pump controls prevent ❑Complies 1.1 supplemental electric resistance heat ❑Does Not [F142)31 from coming on when not needed. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2. Medium Impact(Tier 2) Ka Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 22 of 25 Egan Central Park 2015.cck Section I ' # I Final Inspection. Complies? Comments/Assumptions & RegID C403.2.4. Thermostatic controls have a 5 °F ❑Complies 1.2 deadband. EDoes Not [FI38]3 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies 1.3 overlap restrictions. ❑Does Not [F120]3 ['Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. [Not Observable ❑Not Applicable C403.2.4. Automatic Controls: Setback to 55°F :❑Complies 2.1, (heat) and 85°F (cool); 7-day clock, 2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup [Not Observable [FI40]3 ❑Not Applicable C404.3 Heat traps installed on supply and ;❑Complies [FI11]3 ' discharge piping of non-circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable 0404.4 All piping insulated in accordance with ❑Complies [FI25]2 section details and Table C403.2.10. ❑Does Not ENot Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]' lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ['Not Observable are less than or equal to allowed ❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [FI19]' with what is shown on the approved ❑Does Not lighting plans, demonstrating ❑Not Observable proposed watts are less than or equal to allowed watts. ❑Not Applicable C408.2.1 Commissioning plan developed by !❑Complies [F128]' registered design professional or ❑Does Not approved agency. ❑Not Observable ❑Not Applicable C408.2.3. HVAC equipment has been tested to ❑Complies 1 ensure proper operation. ElDoes Not [F131]' ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies 2 tested to ensure proper operation, ❑Does Not [F110]' calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies [F129]' completed and certified by registered ❑Does Not design professional or approved agency. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2., Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 23 of 25 Egan Central Park 2015.cck Section ! # ! Final Inspection - Complies? Comments/Assumptions &Req.ID f „ C408.2.5. Furnished HVAC as-built drawings ❑Complies 1 submitted within 90 days of system ❑Does Not [F17)3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ❑Does Not [FI16]3 of system acceptance. ['Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies 3 balancing report is provided for HVAC ❑Does Not [F143]1 systems. ❑Not Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies 4 building owner within 90 days of ❑Does Not [F130]' receipt of certificate of occupancy. ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies [F133]' ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) =3 Low Impact(Tier 3) Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 24 of 25 Egan Central Park 2015.cck Project Title: Bank of America Eagan New Store Report date: 03/13/17 Data filename: E:\Dropbox\Projects\2016\ADC\16-232 BofA Egan Central Park\Enery Models\COMCheck\16-232 Page 25 of 25 Egan Central Park 2015.cck