2017 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: Site Address: _�707 //;e 60Y i--/ -- Unit#:
Name: GOk \4 , /)1151 -e..i Phone: /G l t�+® �'���
Resident/ 1 > q
Owner I Address/City/Zip: 000 ,/ o0iv-e ,qv C... be I oN lf'6�Ai I l fie'S'/Z7
Applicant is: Owner X Contractor a 71 e A2/„.L4„, _
�' i Description of work: � � „�,,,,,,�,, ��
/_.
Type of Work
p 13vt1A kZ.W1--1-6(Y1.-e_ lr°' fi /Qt C
i' Construction Cost: 3 '�6 Multi-Family Building: (Yes /No)( )
l Company: iV�/-tt�lll -pryt.¢J Contact: 4� 1e5 /1' 1 1 G4)SA
1 I Address: %QCT &Cx l_' /4-U t. City: G®1 i0l
Contractor u A {
/r p�Jj s--. �? . Email
State: �1`°Lip: ���Z'7 Phone: Z If I irG hi lc:// :60A-1,164 hCII/Yt•et`. CQyY
License#: I?OOZ 9,52-1 Lead Certificate#: A/
If the project is exempt from lead certification, please explain why:
8
--' -- COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILD
ING
I In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan?
Yes /` No If yes,date and address of master plan:
i Licensed Plumber: 5AJ3I2. 1-i- 'f 4 1-764-1 7 Phone: .763-'Z- "97�
/�
1
Mechanical Contractor: ,Aig IZIZ Q..o-41> L ti.. 9 �y Phone: 7 1 2'S 3 -y-7&g
4/Z
i..6 r-4 U -2iZ- 7y6
Sewer&Water Contractor: Se _ -Gv- X C4V9-��.) Phone: ,
a
Fire Suppression Contractor: /VA•
Phone:
3 NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of
the information may be classified as non-public if you providespecific reasons that would permit the City to
conclude that theare trade secrets.
CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours
before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.orq
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approval of plans.
Exterior work authorized by a building permit issued in accordance with the Minnesota State : • Iding Code must be completed within 180
days of permit issuance.
/Y
x Goove,� �.► Arne.,ilk's x
Applicant's Printed Na 9 Appi' nt's Signature
Page 1 of 3
`Z`77'7 ( - co)- - C---a----DO NOT WRITE BELOW THIS LINE /67.P /. --
&
SUB TYPES
Foundation Fireplace Porch (3-Season) Exterior Alteration (Single Family)
Single Family Garage Porch(4-Season) Exterior Alteration(Multi)
Multi Deck Porch (Screen/Gazebo/Pergola) Miscellaneous
01 of_Plex Lower Level Pool Accessory Building
WORK TYPES
New Interior Improvement Siding Demolish Building*
Addition Move Building Reroof Demolish Interior
Alteration Fire Repair Windows Demolish Foundation
Replace Repair Egress Window Water Damage
Retaining Wall *Demolition of entire building—give PCA handout to applicant
DESCRIPTION
Valuation 4/70 01417 Occupancy j — / MCES System
Plan Review Code Edition /0 /5- SAC Units /
(25%_ 100%__Z Zoning /2_/S' City Water .kiiS
Census Code /p/ Stories Booster Pump /140
#of Units / Square Feet AA,Y7 PRV it/0
#of Buildings / Length t/ /-4* Fire Suppression Required Alo
Type of Construction Width G,
REQUIRED INSPECTIONS
Footings (New Building) Meter Size:
lc Footings (Deck) Final/C.O. Required
Footings (Addition) Final/No C.O. Required
A;(... Foundation Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test
At Roof:,sL Ice &Water ot Fina Pool: _Footings _Air/G sts _Final
Framing 30 Minutes 1 Hour Drain Tile
A Fireplace: Rough In ,0- Air Test A. Final Siding: _Stucco Lat > Sto Lath _Brick EFIS
. Insulation Windows
4. Sheathing Retaining Wall: _Footings_ Backfill_Final
c. Sheetrock 44 Radon Control
T Fire Walls Fire Suppression:_Rough In Final
Braced Walls Erosion Control
4. Shower Pan Other:
Reviewed By: / j 4 , Building Inspector
/ i
RESIDENTIAL FEE
�
, = g '
Base Fee 742. 76 7.9
Surcharge 44 U.vp.4/ /p 4 6) /Gym a a /3
Plan Review g-/19 s r6 9�,./j
MCES SAC s-' /��/Z �y/� 9✓� /3f ,BGG y9
City SAC tiA _
Utility Connection Charge r42 / 73G iii@9b %VS I G /8 7
S&W Permit& Surcharge CoAdij g 8>yo 0 *o / 3 3 g IVL 2
Treatment Plant
Copies meet ponhh. 7/g osae 3
TOTAL SCRitriP0IZCle .2,./)10)504i /0 g-,5%0
Page 2 of 3
14y
/qi
New Construction Energy Code Compliance Certificate
Date Certificate Posted
Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel.
3/31/17 I n
Mailing Address of the Dwelling or Dwelling Unit WI Lk'0%0V (CtPer S2.
3787 Wescott Circle
Name of Residential Contractor MN License Number
Gonyea Homes 2459
Community Plan ID
Eagan GH0694
THERMAL ENVELOPE IRADON SYSTEM
o Type:Check All That Apply X Passive(No Fan)
5)
E~ 9 Active(With fan and monometer or
v — '2 �, other system monitoring device)
o � o � U :77-j. 2 ti ,
24 o cC c n w 42, E Location(or future Location)of Fan:
Insulation Location 2. c, U O rd r
o
Y t E -,
ti � 5 1
H z w w oro w rx a Other Please Describe Here
Below Entire Slab X
Foundation Wall(Sides) R-15 X R-10 Exterior,R-5 Interior
Foundation Wall(Front and Back) R-10 X Exterior
Rim Joist(Foundation) R-20 X Interior
Rim Joist(lit Floor+) R-20 X Interior
Wall R-20 X
Ceiling,flat R-49 X
Ceiling,vaulted X
Bay Windows or cantilevered areas R-30 X
Bonus room over garage R-38 X X
Describe other insulated areas
Building Envelope air Tightness: Duct system air tightness:
Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor(excludes skylights and one door)U: 0.29 Not applicable,all ducts located in conditioned space
Solar Heat Gain Coefficient(SHGC): 0.29 R-8 R-value
MECHANICAL SYSTEMS ( Make-up Air Select a Type
Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code
Fuel Type NAT GAS NAT GAS R-410A Passive
Manufacturer Bryant Rheem Bryant Powered
Interlocked with exhaust device.
Model 912SC48080S17 PROG5O42NRH67PV BA13NA042 Describe:
Input in 80000 Capacity in 50 Output in 3.5 Other,describe:
Rating or Size BTUS: Gallons: Tons:
AFUE or 92% SEER or 13 Location of duct or system:
Efficiency HSPF% EER
HEAT LOSS HEAT GAIN COOLING LOAD
RESIDENTIAL LOAD CALC 62,619 33,834 40,413
Cfm's
I "round duct OR
Mechanical Ventilation System "metal duct
Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace Not required per mech.code
Select Type X Passive
Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe:
Energy Recover Ventilator(ERV)Capacity in cfms: Low: 30%783 93 High: 60%=186 Location of duct or system:
Balanced Ventilation Capcity in CFMS: furnace room
Locations of Fans,describe: I Cfm's
Capacity continuous ventilation rate in cfms: � 3 5 "round duct OR
Total ventilation(intermittent+continuous)rate in cfms: 186 "metal duct
3787 Wescott Circle Eagan
HVAC Load Calculations
for
Gonyea Homes
Golden Valley, MN
Prepared By:
Michael Hoium
Sabre Plumbing&Heating
15535 Medina Road
Plymouth, MN 55447
763-473-2267
Friday, March 31, 2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,
Inc.
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 2
Project Report
General Project Information
Project Title: 3787 Wescott Circle Eagan
Designed By: Michael Hoium
Project Date: Friday, March 31, 2017
Client Name: Gonyea Homes
Client City: Golden Valley, MN
Company Name: Sabre Plumbing &Heating
Company Representative: Michael Hoium
Company Address: 15535 Medina Road
Company City: Plymouth, MN 55447
Company Phone: 763-473-2267
Company Fax: 763-473-8565
Design Data
Reference City: Minneapolis, Minnesota
Building Orientation: Front door faces East
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb-15Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: `� -12.38 n/a 30% 72 29.40
Summer: 88 73 50% 50% 75 35
Check Figures
Total Building Supply CFM: 1,534 CFM Per Square ft.: 0.341
Square ft. of Room Area: 4,492 Square ft. Per Ton: 1,334
Volume(ft3): 38,692
Building Loads
Total Heating Required Including Ventilation Air: 62,619 Btuh 62.619 MBH
Total Sensible Gain: 33,834 Btuh 84 %
Total Latent Gain: 6,578 Btuh 16 %
Total Cooling Required Including Ventilation Air: 40,413 Btuh 3.37 Tons(Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
Friday, March 31, 2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 3
Load Preview Report
Net ft' Sen: Lat Net Sena Sys; Sys; Sys` Duct
Scope Ton;, /Toni Area Gain Gain Gain Loss, CFMi CFM• CFM: Size
Building 3.37 1,334 4,492 33,834 6,578 40,413 62,619 740 1,534 1,534
System 1 3.37 1,334 4,492 33,834 6,578 40,413 62,619 740 t. 1* .; 1,534 14x18
Ventilation 999 4,177 5,175 6,685
Supply Duct Latent 210 210
Return Duct 102 91 193 681
Humidification 6,868
Zone 1 4,492 32,733 2,101 34,834 48,384 740 ;. 1,884 1,534 14x18
1-Basement 1,346 5,285 0 5,285 14,815 226 r. 248 248 3--5
2-Main Floor 1,410 17,344 2,101 19,445 17,102 261 813' 813 8--6
3-Second Floor 1,736 10,105 0 10.105 16,467 252 w '47.3.' 473 5--6
Friday, March 31, 2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads is Elite Software Development,Inc,
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 4
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quart Loss Gain Gain Gain
LowEE 2728: Glazing-Windows, u-va 1P 00 2�HG_S..0-28-.28 58 1,363 0 1,587 1,587
LowEE 2833: Glazing-Windows, u-value 0.28, iGC 0.33 62 1,510 0 2,139 2,139
LowEE 3032: Glazing-Windows, u-va- ui3, SHGC 0.32 265.3 6,931 0 8,295 8,295
LowEE 3124: Glazing-Windows, u-value 0.31, SHGC 0.24 17.8 480 0 152 152
LowEE 2832: Glazing-Windows, u-value 0.28, SHGC 0.3L 73.5 1,791 0 2,466 2,466
LowEE 2829: Glazing-Windows, u-aTue11.28, SHGC 0.29, 37 901 0 720 720
Door 23UF• Door-Exterior Door- .23 U Factor, .17 SHGC. 37.8 756 0 208 208
Eagan j 9ft: Wall-Basement, Custom, Eagan-8" 463.5 2,380 0 235 235
poured concrete wall, R-15 board insulation to
foot�in no interior finish, 9'floor depth
Eagan-- 1 4ft: Wall-Basement, Custom, Eagan-8" 98 503 0 49 49
poured concrete wall, R-15 board insulation to
footing, no interior finish, 4'floor death
R20 12F-Osw: Wall-Frame, Custom,l: lnsulation in 2724.1 15,641 0 2,391 2,391
2x6 Cavity, no board insulation, siding finish,wood
studs
Eagan GC 4ft:Wall-Basement, Custom, Eagan-8" 172 883 0 87 87
poure. concrete wall, R-10 board insulation to
footin• no interior finish, 4'floor depth
Eagan 1 sft:Wall-Basement, Custom, Eagan-8" 387 1,986 0 196 196
poured concrete wall, R-10 board insulation to
footing, no interior finish, 9'floor depth
RJ 20 Spray Foam: Wall-Frame, Custom Rim Joist R-20 547.4 2,380 0 672 672
Closed Cell Spray Foam
R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 1802 3,606 0 1,990 1,990
Attic Floor(also use for Knee Walls an&Partition
Ceilings), CustomR-49 Blown Insulato No
Radiant Barrier, Vented Attic,Asphalt Shingles
21A-20: Floor-Basement, Concrete slab, any thickness, 2 1346 3,162 0 0 0
or more feet below grade, no jfizgatisajejaw2221,
any floor cover, shortest side of floor slab is 20'wide
20P-31: Floor-Over open crawl space or garage, Passive, 66 201 0 19 19
-30 blanket insulation, any cover
20P- 8: Floor-Over open crawl space or garage, Passive, 347.8 908 0 84 84
blanket insulation, any cover
Subtotals for structure: 45,382 0 21,290 21,290
People: 6 1,200 1,380 2,580
Equipment: 901 4,116 5,017
Lighting: 1250 4,263 4,263
Ductwork: 3,683 301 755 1,056
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation:Winter CFM: 180, Summer CFM: 180 6,685 4,177 999 5,175
Humidification (Winter) 18.73 gal/day : 6,868 0 0 0
AED Excursion: 0 0 1,032 1,032
Total Building Load Totals: 62,619 6,578 33,834 40,413
Check Figures
Total Building Supply CFM: 1,534 CFM Per Square ft.: 0.341
Square ft. of Room Area: 4,492 Square ft. Per Ton: 1,334
Volume(ft3): 38,692
Building Loads
Total Heating Required Including Ventilation Air: 62,619 Btuh 62.619 MBH
Total Sensible Gain: 33,834 Btuh 84 %
Total Latent Gain: 6,578 Btuh 16 %
Total Cooling Required Including Ventilation Air: 40,413 Btuh 3.37 Tons(Based On Sensible+ Latent)
Notes
Friday, March 31, 2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.'
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 5
Total Building Summary Loads (cont'd)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
Friday, March 31, 2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc,
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 6
Detailed Room Loads - Room 9 - Basement (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 26.9 ft. System Number: 1
Room Width: 50.0 ft. Zone Number: 1
Area: 1,346.0 sq.ft. Supply Air: 248 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.2 AC/hr
Volume: 12,114 cu.ft. Req.Vent. Clg: 0 CFM
Number of Registers: 3 Actual Winter Vent.: 55 CFM
Runout Air: 83 CFM Percent of Supply.: 22 %
Runout Duct Size: 5 in. Actual Summer Vent.: 29 CFM
Runout Air Velocity: 605 ft./min. Percent of Supply: 12 %
Runout Air Velocity: 605 ft./min. Actual Winter Infil.: 0 CFM
Actual Loss: 0.293 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HIM Loss HIM Gain Gain
N-Wall-Eagan- R15 9ft 28 X 9 252 0.042 5.1 1,294 0.5 0 128
N-Wall-Eagan- R15 4ft 10 X 4 40 0.041 5.1 205 0.5 0 20
N-Wall-R20 12F-Osw 10 X 5 50 0.066 5.7 287 0.9 0 44
W-Wall-Eagan - R10 4ft 43 X 4 172 0.054 5.1 883 0.5 0 87
W-Wall-R20 12F-0sw 43 X 5 125 0.066 5.7 718 0.9 0 110
S-Wall-Eagan- R15 4ft 14.5 X 4 58 0.041 5.1 298 0.5 0 29
S-Wall-R20 12F-Osw 14.5 X 5 62.5 0.066 5.7 359 0.9 0 55
S-Wall-Eagan- R15 9ft 23.5 X 9 211.5 0.042 5.1 1,086 0.5 0 107
E-Wall-Eagan- R10 9ft 43 X 9 387 0.050 5.1 1,986 0.5 0 196
N-Wall-RJ 20 Spray Foam 40 X 1.7 66.7 0.050 4.4 290 1.2 0 82
W-Wall-RJ 20 Spray Foam 45 X 75 0.050 4.4 326 1.2 0 92
1.7
S-Wall-RJ 20 Spray Foam 40 X 1.7 66.7 0.050 4.4 290 1.2 0 82
E-Wall-RJ 20 Spray Foam 45 X 1.7 75 0.050 4.4 326 1.2 0 92
S-GIs-LowEE 2728 shgc-0.28 0%S 10 0.270 23.5 235 16.3 0 163
W-GIs-LowEE 2728 shgc-0.28 48 0.270 23.5 1,128 29.7 0 1,424
0%S (4)
W-GIs-LowEE 2833 shgc-0.33 42 0.280 24.4 1,023 34.5 0 1,449
0%S (3)
Floor-21A-20 50X 26.9 1346 0.027 2.3 3.,162 0.0 0 0
Subtotals for Structure: 13,896 0 4,160
Infil.:Win.: 0.0, Sum.: 0.0 1,741 0.000 0 0.000 0 0
Ductwork: 919 105
AED Excursion: 167
Lighting: 250
_._....853
Room Totals: 14,815 0 5,285
Friday, March 31,2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.'
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 7
Detailed Room Loads - Room 2 - Main Floor(Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 28.2 ft. System Number: 1
Room Width: 50.0 ft. Zone Number: 1
Area: 1,410.0 sq.ft. Supply Air: 813 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 3.8 AC/hr
Volume: 12,690 cu.ft. Req.Vent. CIg: 0 CFM
Number of Registers: 8 Actual Winter Vent.: 64 CFM
Runout Air: 102 CFM Percent of Supply.: 8 %
Runout Duct Size: 6 in. Actual Summer Vent.: 95 CFM
Runout Air Velocity: 517 ft./min. Percent of Supply: 12 %
Runout Air Velocity: 517 ft./min. Actual Winter Infil.: 0 CFM
Actual Loss: 0.167 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Item Area -U- Htg Sen CIg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N-Wall-R20 12F-Osw 40 X 9 333.2 0.066 5.7 1,913 0.9 0 292
W-Wall-R20 12F-0sw 45 X 9 259.5 0.066 5.7 1,490 0.9 0 228
S-Wall-R20 12F-Osw 40 X 9 348 0.066 5.7 1,998 0.9 0 305
E-Wall-R20 12F-0sw 45 X 9 287.9 0.066 5.7 1,653 0.9 0 253
N-Wall-RJ 20 Spray Foam 42 X 1.5 63 0.050 4.4 274 1.2 0 77
W-Wall-RJ 20 Spray Foam 46 X 69 0.050 4.4 300 1.2 0 85
1.5
S-Wall-RJ 20 Spray Foam 42 X 1.5 63 0.050 4.4 274 1.2 0 77
E-Wall-RJ 20 Spray Foam 46 X 1.5 69 0.050 4.4 300 1.2 0 85
E-Door-Door 23UF 3 X 6.7 20 0.230 20.0 400 5.5 0 110
E-Door-Door 23UF 2.7 X 6.7 17.8 0.230 20.0 356 5.5 0 98
N-GIs-LowEE 3032 shgc-0.32 9 0.300 26.1 235 10.0 0 90
100%S
N-GIs-LowEE 3124 shgc-0.24 17.8 0.310 27.0 480 8.5 0 152
100%S
W-GIs-LowEE 3032 shgc-0.32 0%S 9 0.300 26.1 235 33.8 0 304
W-GIs-LowEE 3032 shgc-0.32 0%S 13.5 0.300 26.1 352 33.8 0 456
W-GIs-LowEE 3032 shgc-0.32 49.5 0.300 26.1 1,293 33.8 0 1,674
0%S(3)
W-GIs-LowEE 2832 shgc-0.32 73.5 0.280 24.4 1,791 33.6 0 2,466
0%S(3)
S-GIs-LowEE 2829 shgc-0.29 0%S 12 0.280 24.4 292 16.8 0 202
E-GIs-LowEE 3032 shgc-0.32 0%S 66 0.300 26.1 1,724 33.8 0 2,232
(4)
E-GIs-LowEE 3032 shgc-0.32 0%S 13.3 0.300 26.1 348 33.7 0 450
(2)
UP-Ceil-R49 16B-49 19 X 2 38 0.023 2.0 76 1.1 0 42
UP-Ceil-R49 16B-49 14 X 2 28 0.023 2.0 56 1.1 0 31
Floor-20P-30 2 X 19 38 0.035 3.0 116 0.3 0 11
Floor-20P-30 2 X 14 28 0.035 3.0 85 0.3 0 8
Subtotals for Structure: 16,041 0 9,728
Infil.:Win.: 0.0, Sum.: 0.0 1,794 0.000 0 0.000 0 0
Ductwork: 1,061 346
AED Excursion: 547
People: 200 lat/per, 230 sen/per: 6 1,200 1,380
Equipment: 901 3,638
Lighting:
500 _._ 1,705
Room Totals: 17,102 2,101 17,344
Friday, March 31, 2017, 11:40 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,inc.
Sabre Plumbing&Heating 3787 Wescott Circle Eagan
Plymouth,MN 55447 Page 8
Detailed Room Loads - Room 3 - Second Floor(Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 34.7 ft. System Number: 1
Room Width: 50.0 ft. Zone Number: 1
Area: 1,736.0 sq.ft. Supply Air: 473 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 2.0 AC/hr
Volume: 13,888 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 5 Actual Winter Vent.: 61 CFM
Runout Air: 95 CFM Percent of Supply.: 13 %
Runout Duct Size: 6 in. Actual Summer Vent.: 56 CFM
Runout Air Velocity: 482 ft./min. Percent of Supply: 12 %
Runout Air Velocity: 482 ft./min. Actual Winter Infil.: 0 CFM
Actual Loss: 0.145 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Item Area -U- Htg Sen Cg Lat Sen
Description Quantity Value HIM Loss HIM Gain Gain
N -Wall-R20 12F-Osw 42 X 8 336 0.066 5.7 1,929 0.9 0 295
W-Wall-R20 12F-0sw 46 X 8 341 0.066 5.7 1,958 0.9 0 299
S-Wall-R20 12F-0sw 42 X 8 288 0.066 5.7 1,654 0.9 0 253
E-Wall-R20 12F-0sw 46 X 8 293 0.066 5.7 1,682 0.9 0 257
W-GIs-LowEE 2833 shgc-0.33 0%S 20 0.280 24.4 487 34.5 0 690
W-GIs-LowEE 2829 shgc-0.29 0%S 7 0.280 24.4 171 30.7 0 215
S-GIs-LowEE 3032 shgc-0.32 0%S 30 0.300 26.1 784 18.5 0 554
(2)
S-GIs-LowEE 2829 shgc-0.29 0%S 18 0.280 24.4 438 16.8 0 303
E-GIs-LowEE 3032 shgc-0.32 0%S 75 0.300 26.1 1,960 33.8 0 2,535
(5)
UP-Ceil-R49 16B-49 34.7 X 50 1736 0.023 2.0 3,474 1.1 0 1,917
Floor-20P-38 18.5 X 17.5 323.8 0.030 2.6 845 0.2 0 78
Floor-20P-38 2 X 12 24 0.030 2.6 63
Subtotals for Structure: 15,445 0 7,402
Infil.:Win.: 0.0, Sum.: 0.0 1,408 0.000 0 0.000 0 0
Ductwork: 1,022 202
AED Excursion: 319
Equipment: 0 478
Lighting. 500 1,705
Room Totals: 16,467 0 10,105
Friday, March 31,2017, 11:40 AM
Site address 3787 Wescott Circle, Eagan MN Date 1 3/31/201 7
Contractor Sabre Heating And NC Completed
Byd Michael H
Section A
Ventilation Quantity
(Determine quantity by using Table R403.5.2 or Equation 11-1)
Square feet(Conditioned area including 4492 Total required ventilation 180
Basement—finished or unfinished) -
Continuous ventilation
5 90
Number of bedrooms
Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1.
The table and equation are below
Table R403.5.2
Total and Continuous Ventilation Rates(in cfm)
Number of Bedrooms
1 2 3 4 5 6
Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/
sn.ft.) continuous continuous continuous continuous continuous continuous
1000-1500 60/40 75/40 90/45 105/53 120/60 135/68
1501-2000 70/40 85/43 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110/55 125/63 140/70 155/78
2501-3000 90/45 105/53 120/60 135/68 150/75 165/83
3001-3500 100/50 115/58 _130/65 145/73 160/80 175/88
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 165/83 (.80/90) 195/98
4501-5000 130/65 145/73 160/80 175/88 190JS5 205/103
5001-5500 140/70 155/78 170/85 185/93 200/100 215/108
5501-6000 150/75 165/83 180/90 195/98 210/105 225/113
Equation 11-1
(0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm)
Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate
average,for each one-hour period according to the above table or equation.For heat recovery ventilators(HRV)and energy
recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of
exhaust or out outdoor air intake,or both,for defrost or other equipment cycling.
Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided,
on a continuous rate average for each one-hour period.The portion of the mechanical ventilation system intended to be
continuous may have automatic cycling controls providing the average flow rate for each hour is met.
Section B
Ventilation Method
(Choose either balanced or exhaust only)
Balanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recovery l� Exhaust only
Ventilator)—cfm of unit in low must not exceed continuous I I Continuous fan rating in cfm
ventilation rating by more than 100%.
Low cfm: �� High cfm: ^�� Continuous fan rating in cfm(capacity must not exceed
continuous ventilation rating by more than 100%)
Directions-Choose the method of ventilation,balanced or exhaust only.Balanced ventilation systems are typically HRV or ERV's.
Enter the low and high cfm amounts.Low cfm air flow must be equal to or greater than the required continuous ventilation rate and
less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the ventilation fan must not exceed 80 cfm.)
Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Section C
Ventilation Fan Schedule
Description Location Continuous Intermittent
Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it is used for continuous
or intermittent ventilation.The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating
and less than 100%greater than the continuous rote.(For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not
exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour.
Section D
Ventilation Controls
(Describe operation and control of the continuous and intermittent ventilation)
ERV has wall control set to 30%=93 CFM
ERV has wall control set to 60%=186 CFM
Directions-Describe the operation of the ventilation system.There should be adequate detail for plan reviewers and inspectors to verify design and
installation compliance.Related trades also need adequate detail for placement of controls and proper operation of the building ventilation.if exhaust fans
are used for building ventilation,describe the operation and location of any controls,indicators and legends.If an ERV or HRV is to be installed,describe how
it will be installed.If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures'
installation instructions.If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper
operation,such interconnection shall be made and described.
Directions-In order to determine the makeup air,Table 501.4.1 must be filled out(see below).For most new installations,column A will be appropriate,however,if
atmospherically vented appliances or solid fuel appliances are installed,use the appropriate column. Please note,if the makeup air quantity is negative,no additional makeup air
will be required for ventilation,if the value is positive refer to Table 501.4.2 and size the opening.Transfer the cfm,size of opening and type(round,rectangular,flex or rigid)to
the last line of section D.
Table 501.4.1
PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS
(Additional combustion air will be required for combustion appliances,see KAIR method for calculations)
One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical-
vent or direct vent ap-pliances assisted appliances and power gas or oil appliance or one solid ly vented gas or oil appliances
or no combus-tion appliances vent or direct vent appliances fuel appliance or solid fuel appliances
Column D
Column A Column B Column C
1. 0.15 0.09 0.06 0.03
a)pressure factor
(cfm/sf)
b)conditioned floor area(sf)(including 4492
unfinished basements)
Estimated House Infiltration(cfm):[1a 674
x Sb]
2.Exhaust Capacity
a)continuous exhaust-only ventilation system ERV = 0
(cfm);(not applicable to ba-lanced ventilation
systems such as HRV)
b)clothes dryer(cfm) 135 135 135 135
Oftt c)80%of largest exhaust rating(cfm);
,... /110 t r/� Kitchen hood typically 240
VV • [-w (not applicable if recirculating system or if
powered makeup air is electrically interlocked
rl(1d)80%of next largest exhaust rating Not
j (cfm);bath fan typically
Applicable
(not applicable if recirculating system or if
powered makeup air is electrically interlocked
Total Exhaust Capacity(cfm);
[2a+2b+2c+2d1 375
3.Makeup Air Quantity(cfm) 375
a)total exhaust capacity(from above)
b)estimated house infiltration(from 674
above)
Makeup Air Quantity(cfm);
[3a—ub] -299
(if value is negative,no makeup air is needed)
4.For makeup Air Opening Sizing,refer
to Table 501.4.2 NOT REQ.
A.Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent
appliances may be used.)
B.Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may also be included.)
C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance.
D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid
fule appliances.
Table 501.4.2
Makeup Air Opening Sizing Table for New and Existing Dwelling Units
One or multiple power One or multiple fan- One atmospherically vented Multiple atmospherically Duct di-
vent,direct vent ap- assisted appliances and gas or oil ap- vented gas or oil ap- ameter
pliances,or no combus- power vent or direct vent pliance or one solid fuel pliances or solid fuel
tion appliances appliances Column B appliance appliances
Passive opening 1-36 1-22 1-15 1-9 3
Passive opening 37-66 23-41 16-28 10-17 4
Passive opening 67—109 42—66 29—46 18—28 5
Passive opening 110-163 67-100 47-69 29-42 6
Passive opening 164-232 101-143 70-99 43-61 7
Passive opening 233-317 144-195 100-135 62-83 8
Passive opening 318-419 196-258 136-179 84-110 9
w/motorized damper
Passive opening 420-539 259-332 180-230 111-142 10
w/motorized damper
Passive opening 540-679 333-419 231-290 143-179 11
w/motorized damper
Powered makeup air >679 >419 >290 >179 NA
Notes:
A.An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to
determine the remaining length of straight duct allowable.
B.If flexible duct is used,increase the duct diameter by one inch.Flexible duct shall be stretched with minimal sags.Compressed duct shall not be accepted.
C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
D.Powered makeup air shall be electrically interlocked with the largest exhaust system.
Combustion air .
Not required per mechanical code(No atmospheric or power vented appliances)
✓ Passive(see IFGC Appendix E,Worksheet E-1) Size and type 14"ridged 5"flex
'Other,describe:
Explanation-If no atmospheric or power vented appliances are installed,check the appropriate box,not required.If a power vented
or atmospherically vented appliance installed,use IFGC Appendix E,Worksheet E-1(see below).Please enter size and type.Combustion
air vent supplies must communicate with the appliance or appliances that require the combustion air.
Section F calculations follow on the next 2 pages.
Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air
Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out.
IFGC Appendix E,Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace,Boiler,and/or Water Heater in the Same Space)
Step 1:Complete vented combustion appliance information.
Furnace/Boiler: 80000
raft Hood Dan Assisted [irect Vent Input: Btu/hr or Power Vent
Water Heater: 40000
raft Hood ZFan Assisted ❑Direct Vent Input: Btu/hr or Power Vent
Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 792 ft3
LxWxH nL 11 WnH
Step 3:Determine Air Changes per Hour(ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use
method 4a(Standard Method).
Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES)
4a.Standard Method
Total Btu/hr input of all combustion appliances Input: Btu/hr
Use Standard Method column in Table E-1 to find Total Required TRV: _ ft3
Volume(TRV)
If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.
If CAS Volume(from Step 2)is less th an TRV then go to STEP 5.
4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES)
Total Btu/hr input of all fan-assisted and power vent appliances Input: 40000 Btu/hr
Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3000 ft3
Required Volume Fan Assisted(RVFA)
Total Btu/hr input of all Natural draft appliances Input: 0 Btu/hr
Use Natural draft Appliances column in Table E-1 to find RVNFA: 0 ft3
Required Volume Natural draft appliances(RVNDA)
Total Required Volume(TRV)=RVFA+RVNDA TRV= 3000 + 0 3000 TRV ft3
Step S:Calculate the ratio of available interior volume to the total required volume.
Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b)
Ratio= 792 / 3000 = 0.26
Step 6:Calculate Reduction Factor(RF).
RF=1 mi n us Ratio RF=1- 0.26 = 0.74
Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000
Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air Opening Area(CAOA):
Total Btu/hr divided by 3000 Btu/hr per inz CAOA= 40000 /3000 Btu/hr per inz= 13.33 inz
Step 8:Calculate Minimum CAOA.
Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 13.33 x 0.74 = 9.81 inz
Step 9:Calculate Combustion Air Opening Diameter(CAOD)
CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 3.54 in.diameter go up one inch in size
if using flex duct
1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section
G304.
IFGC Appendix E,Table E-1
Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance)
Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method(cu ft)
(Btu/hr)
Fan Assisted or Power Vent Natural Draft
1994 to present Pre-1994 1994 to present Pre-1994
5,000 250 375 188 525 263
10,000 500 750 375 1,050 525
15,000 750 1,125 563 1,575 788
20,000 1,000 1,500 750 2,100 1,050
25,000 1,250 1,875 938 2,625 1,313
30,000 1,500 2,250 1,125 3,150 1,575
35,000 1,750 2,625 1,313 3,675 1,838
40,000 2,000 3,000 1,500 4,200 2,100
45,000 2,250 3,375 1,688 4,725 2,363
50,000 2,500 3,750 1,675 5,250 2,625
55,000 2,750 4,125 2,063 5,775 2,888
60,000 3,000 4,500 2,250 6,300 3,150
65,000 3,250 4,875 2,438 6,825 3,413
70,000 3,500 5,250 2,625 ,7,350 3,675
75,000 3,750 5,625 2,813 7,875 3,938
80,000 4,000 6,000 3,000 8,400 4,200
85,000 4,250 6,375 3,188 8,925 4,463
90,000 4,500 6,750 3,375 9,450 4,725
95,000 4,750 7,125 3,563 9,975 4,988
100,000 5,000 7,500 3,750 10,500 5,250
105,000 5,250 7,875 3,938 11,025 5,513
110,000 5,500 8,250 4,125 11,550 5,775
115,000 5,750 8.625 4,313 12,075 6,038
120,000 6,000 9,000 4,500 12,600 6,300
125,000 6,250 9,375 4,688 13,125 6,563
130,000 6,500 9,750 4,875 13,650 6,825
135,000 6,750 10,125 5,063 14,175 7,088
140,000 7,000 10,500 5,250 14,700 7,350
145,000 7,250 10,875 5,438 15,225 7,613
150,000 7,500 11,250 5,625 15,750 7,875
155,000 7,750 11,625 5,813 16,275 8,138
160,000 8,000 12,000 6,000 16,800 8,400
165,000 8,250 12,375 6,188 17,325 8,663
170,000 8,500 12,750 6,375 ,17,850 8,925
175,000 8,750 13,125 6,563 18,375 9,188
180,000 9,000 13,500 6,750 18,900 9,450
185,000 9,250 13,875 6,938 19,425 9,713
190,000 9,500 14,250 7,125 19,950 9,975
195,000 9,750 14,625 7,313 ,20,475 10,238
200,000 10,000 15,000 7,500 21,000 10,500
205,000 10,250 15,375 7,688 21,525 10,783
210,000 10,500 15,750 7,875 22,050 11,025
215,000 10,750 16,125 8,063 22,575 11,288
220,000 11,000 16,500 8,250 23,100 11,550
225,000 11,250 16,875 8,438 23,625 11,813
230,000 11,500 17,250 8,625 24,150 12,075
1.The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is
0.20 ACH.
2.This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH.
d*''
'IL4; l-
City Inspection Dept. Copy City of aau
City Forester Copy
Applicant/Builder Copy
A 1.40
TRE
CITY O A X 111 FORES R e
z r xr w v�..
65
3�
(BUILDER, PLEASE READ ATTACHMENTS)
Development Willow Ridge
Lot Number 8 Block Number 1
Address 3787 Wescott Circle
Builder Gonvea Homes
Phone Number: 612-940-5660
Contact: James Michka
Tree Protection Requirements:
X Tree Protection Fencing Installed on Site(orange silt fence)
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
Replacement Trees:
Not Required
X As Follows: Two(2)4"caliper Northwood Maple tree in front yard
area to be installed following completion of construction.
Attachments:
X Yes (Refer to attacped�i rjietk f •
rR i DIVISION
No I
REVIEW D
7/0L
Additional Notes: BY
H:\ghcve\2017file\treepres\Tree Pr ery on Plan Willow Rid)Lot 8 Block 1
i
DATEaw�q�ir.
ml 1 I 2 g t2
z z z o Ls o
€aso I __I9 T.sis k
4 a w w 0 F a g ¢ z I wi` .�
eg 1
- w z z z z O z T § > 477 oy��i w w 0 a5G 6 o O illuiH CO 413
.1 41g 0.41. 1
W 0Cb - L_ w , I gill IQ It
WMM f O • . LioJFD4004a o = 4 Etas Id
Q s, Q V
§e 1 I„„s".2 i, �6 : a
m
3�0*El i0 x- a o w
811.O3S3MXI n II .6
§ €L IJJ
laew LS9Z a 0 tz=.1" I w
~ 6tij'9Lt a -----_
w SI /Yn2p
g-P
1r.�, -'-'f rS f'-m 9N101Ina OF g
l IRI K51 xm x �- j 1_n
I 1 I �� � Nx x J
,0015—+ a
` lAotoi 000z I • U
$Rosie 1wna.1t f F 0'.. N
O je • °'u 15 w._
;44 Ci O i S c,, U w os a °g�` o
til
1��; : I 12 00 LI �a "b„ x< w 0 cc o
Cg L.1-1 472 NI
3 0 g ,. om a35oaoea v, Z W a
z q^
al b
�'r� ,fi NO I J,...r— ` oo[a x I"+ Z a O�F +a
�+1 T `� -i ,I °' L1C lg 4 g-o �l W o$ W yJTi3F;a3 ¢ S
1 O Q xt -- a tenwer. xJVe135 & I ; O n LL g z g 9 z ...2
N.,' � g83 ,,,=,° X`SNiaine,sz � . w� R o R c w a 2 -6
4.4 N1 iII3 ppz o Sz o Waw o wvi
Q CU�}' e �� x3re135 NON,sl w R I x ! „4,4Ogg p�,C7 ¢ ¢ O Z o
C� nl `_ Is ccm irSugm VI,:
5 cozz' gw,9zF
W Q _RI g10_ ducts QNY113M° _1_„ wm 2 Cry lu zOZWF pW
v' pp55 _ }}��
MM �30''� w 17J g ?NW¢ wS�.L
C N m CO g C 5Q30 C aiw� �o5 00.40
x S J
�� Q COo 3 T� m $ (9 a a of m c
V
O o ellg _114 i'
;7.'4 o0 ,
11. irit
, 0
-CO ,..,...:,...,.... --
ICk
CO 114'
V
WI _ �� .,i7j�� onwom
N� o W a a+O C�''L 4 Fi § m
N tel.R0 � ay n n n n n =
aQ�®N lt 0 E. ...m of
3it-iOo , x[w]
h 0 $./1 W - aG z V
oh Cn �d 2 n6 z= a a. go
r00 W 3§ t',j on `&,Som Q aQQR¢"y zLL
2 Q U4 c n pWZ¢ cn r.04608$2 Oz
...10 - N xE 688900 O W$ V k-a
V m q z E. a miiay CiWgili$ q
til 98 Q', t+l til Jg a. °C7mo 04 HQ
24 \ ,!':, %Y ET ;� s
i.% ::::: :;•:: i'ii ::••: /f:5i:i.Q ;; 4i
.M•! ".,„:.:.:::„:•::.•,...,,,,f,,,..:::::!
\ �� � �. .�::�•'• �
/ \ ' `q)
\ Wc1T1<
. :::..• sow
0� ♦ �fi :.� ,""'� ; : `-�'►.;.�Wit: r- .:.;, �..�
..4464_
, ; fir. i:iciy• ‘
N,_ 1 \ t:.: s'ttr:::•:•;:;.. ',.;:, :',:•-•,:. :. :, -;ilti-lai :T7:T.,!:•i,7tr,'!7., ;:i:',.4.7b.,.:iii:i-::":•:i iN..14.-c.,.740,„
„.. ,
/ -......1 * . /A , a \ , . v:::.„. .::::::,:„.. :. :‘::::::::.:i:,„: „„„,::::,„:/„ „„,:„:,.:: :::,,::: .,,:: •••....,.. ....:,:.1:•,,,::_ ,
r ` .."....s. ..-2.;
� \\F :r ,a., ` , ..��1777
. os
;01, \ir‘', -. '.11 I . /A 4%1_ . . . • . . . . . . . . . . . .• • \.. ,, , ., 1
, , ..,........,....,. 1
I ..,...., ,
_ lit
/4‘11,,,t, .40 / __
......t..,, ,,,,_4/V1/4
I_ „,....,.. ._
J; t "” 1. 1 '
` .i..,i7_I•.-„,.....,r
.'•,./
,,,____„..
1.
_I
____,,2.,[
\ � d
----- Tir ligr.-WANir
'. '-. r•TA.131.1.011h011.111/441tr-will Witigiv ili Pi" rit / 14111 0:
,.., \ , p Alrok &fa,„, ; i , ..
. \ fliAllir 44k• ' V,N. i II i / ' , ' r*-.:L-->‘-- Cs.",. I . -'--‘.--- • _.-,--
1 1. - 1 o N
P1min 1, mom `
--- 1 1 I 41 i w .l
} 1
\ _ ,
-. Cr4L._.___.__ Il •. V ___./ / : [., , .. y--— 1 N -
1
__..__'-K.... _ \
` _ \ Ohl: \ �� ��\
\ I ,�
..-..., _ ._., -,,, . ,,,,.........451, )..1.... ) 1,.../- 1---, I i / ''7
.- 'f • i.
L1 . 1?�: .l :a:::: :•:i 1.,i.::::"•:::4:41pi �,d�o?'' .r ;\/,, h t \ ti y ' • t
{� f n 1�_/. I . �a qlw b a: a nom` 1 i \ \1
•/1 a E -��:•'�.r.; tit, / ; moi ! •( �.t '\.
'' ..•:........:::,:i:i:/ --.. , - ......,.... s......:,.:...t....... --'7,,:•:•:::05:::. ..,,., , , 1 4,4...::. ,...:.,v,...111111R1 ,.....„„,:z. \ .......;\ L. ita.
t 1 �� 7i ,,1 ;al I :f.. ': ` Com, .(
41 I - 41..._.,,,,..71-. -.ii .-1 .1,1 '. �j; -1 'i. ._I •.jI :+, '.� 1 ,\' a.' ®�' L l, i it
4.
ft 1
At
t , I 111 6hI ' \' � jAl±1 1 It , -.-- C ....1 ! t j
,'I '''11 Io - \ - \ ,1 t - 1
7 -` ` y': t - yl �' • • l t , ea4�
...._
-, al-) ril -, 0 -,
� i �' t `� i J� 3{ t i �3...
, - .--
.\
�r y
-I \ 4 1 I fAI 771 ,:i.i 1 :11 i .1 1 -..1 9 ,11.' -;-.1illtrii I , 7-1. -:.li I Ls1 . \
i 4 C9 -•f 1
..AI �, € I y Z.. 11 j\ _ 1
y‘ s\ 44pLialet-11101E-A111
!a
v ..1 •:11 11 :J: 1 1i y fit. j IITr
TREE MITIGATION SCHEDULE:
QTY. KEY COMMON NAME/BOTANICAL NAME SIZE REMARKS
OVERSTORY TREES
1 HB(M) HACKBERRY/Celtis occidentalis* 4" CAL B&B STRAIGHT TRUNK, NO V—CROTCH
5 HL(M) HONEYLOCUST/Gleditisia triacanthos var. inermis 'Skycole'* 4" CAL B&B STRAIGHT TRUNK, NO V—CROTCH
10 NM(M) NORTHWOOD RED MAPLE/Acer rubrum 'Northwood'* 4 CAL. B&B STRAIGHT TRUNK, NO V—CROTCH
14 WO(M) SWAMP WHITE OAK/Quercus bicolor* 4" CAL B&B. STRAIGHT TRUNK, NO V—CROTCH
CO tFERS
13 BF(M) BALSAM FIR/Abies balsamea* 12' HT. B&B FULL FORM
20 BS(M) BLACKHILLS SPRUCE/Picea glauca densata* 12' HT. B&B FULL FORM
63 TOTAL TREES FOR MITIGATION 252" TOTAL CALIPER INCHES
NOTES: QUANTITIES ON PLAN SUPERSEDE LIST QUANTITIES IN EVENT OF DISCREPANCY.
THESE QUANTITIES AND SPECIES ARE ALSO SHOWN.ON THE LANDSCAPE PLAN ON SHEET 14.
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION lG
PROPERTY LEGAL: lel 1 -k i k4 1141.)
DATE OF SURVEY: -V3///
LATEST REVISION:
as
as
as 7e 14,18 < (-6)#
0 z a DOCUMENT STANDARDS
' ❑ ❑ • Registered Land Surveyor signature and company
❑ ❑ • Building Permit Applicant
XCT ❑ ❑ • Legal description
/Jiff ❑ ❑ • Address
❑ ❑ • North arrow and scale
g ❑ ❑ • House type(rambler,walkout,split w/o, split entry, lookout,etc.)
,la' ❑ ❑ • Directional drainage arrows with slope/gradient%
yf' ❑ ❑ • Proposed/existing sewer and water services&invert elevation
,' ❑ ❑ • Street name
g ❑ ❑ • Driveway(grade&width-in R/W and back of curb,22' max.)
A ❑ ❑ • Lot Square Footage
C/ ❑ 0 • Lot Coverage
ELEVATIONS
Existing
• ❑ ❑ • Property corners
❑ 0 • Top of curb at the driveway and property line extensions
❑ Jf ❑ • Elevations of any existing adjacent homes
/ ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches
❑ ❑ • Waterways(pond, stream,etc.)
Proposed
❑ ❑ • Garage floor
❑ ❑ • Basement floor
Al ❑ ❑ • Lowest exposed elevation(walkout/window)
, ❑ ❑ • Property corners
�J ❑ ❑ • Front and rear of home at the foundation
Y ( • PRV Required
PONDING AREA(if applicable)
�J ❑ ❑ • Easement line
• ❑ • NWL
❑ ,ef ❑ • HWL
❑ 2' ❑ • Pond#designation
❑ ❑ • Emergency Overflow Elevation
:1 • Pond/Wetland buffer delineation
Y4) • Shoreland Zoning Overlay District
Y • Conservation Easements
DIMENSIONS
❑ ❑ • Lot lines/Bearings&dimensions
❑ $ ❑ • Right-of-way and street width(to back of curb)
• ❑ ❑ • Proposed home dimensions including any proposed decks,overhangs greater than 2', porches,etc.
(i.e.all structures requiring permanent footings)
❑ ❑ • Show all easements of record and any City utilities within those easements
y7 ❑ ❑ • Setbacks of proposed structure and .rdd-tback of adjacent existing structures
,d ❑ ❑ • Retaining wall requirements:
Reviewed By://) I,►:tr/ Date/4/ZZ_____/(9
G:/1 Engineering/FORMS/Cert.of Survey Checklist Rev.11-16-16
C O .n
O-c
z
„oM co ..
w a at a
J\ EC 2 u) O43E° n Waig2 U
Z Q ❑ 0
O J Z O CL O J .O..O r0 O)y O o M
i z O z w 0 W LL LU _O p :�N u w eco o=
O I- Q V) W > w -) 0 Q 0LiJ cc Z D• o J a- n n `'•
Q▪ > 0 Z Z > m J 02 W W Z I- W O 0 a E a J •N M C N N 3
_.-t > J LL w W O () O Z (n J o CL a O LL U c v" < c'J o m 3
\� W W O } VJ m = Q p W U H Q ❑ O W
fill��^ ^,n
V W ❑ Z ❑ a U O LL J Z Z ❑ ❑ ❑ a ❑ CO ~ ° \�' n
W z Z Z Z O Z a , Q Q } w W W w 0 D Q ❑ O a Y�J O N
J l V U 0 O O O p I- W F U > CC (n (n U) Z o W Z CC O °T v <1
�-' ▪ a W Lu
Z ZJ W I- ¢ liCC W Y AOu
CC O O Q ) 2 0 0 < Q p O > W CC E .� Ea)e a
y°aq W a ❑ ¢ ccz O w J I- CO u) LL a a a co J O ° �
3
a, o y
N Cl...-.y.n r O
r� Q > 450-0 no.,I C ° 0
C...5
W _3 0 N 0 0_ VI 0 1..1..1
W 44 N) 4 7 0 • 4 0 o o N OQo < = a
rn C.�
rn 0 Y Z
n_
n v m rX O ''
a f4 o gl co o s.ij J
N)I
a � My m ma
m O U 3
o v o J Q
X
310100 o O w
o n o CO
o \ J
LX ^o r .. m v ac a x o 5
110�S�►M X Q �: z =oO. ooLB w
X ` °
n ,rn �/y/ ro J rn oM m �"�; F E o _
R.
di ^ �X M \O Vf? �—°mr ;R�; (�^�D rO ¢ . ....A. "1 co)
1..� (7 lY < N li
�Q S— �� w
o Xao �pcv� Z0 00 SZZ=� e 00 Q 0 Ed» (:3!_.? c� w
r.....1 [jam" ‹' Ii
Irn ''-'t
ZZ 1� \f rn _- o ;XyJy, 0`" iG / � ,W/� L::
\ 11 �6�•'V�% O -Ota——— X__O p m ,� V vs _RT
•
� e wa IC6'40(1°''`�UO 9 -1 jv S 01 W
^��jj `"� X ,� o; '��Zst:::IL(c)
�o n ‘® o� / rnli� Urnz MiO
^ To-
r:;.•
° wQ�i ni
�� Z
�°— r r 00
va NOV813S rn r
® a s S •
9NIOlo 2 .0£ aco
4W^
o ? i ac o .n M
444 Z ' —
O I 1 R I I N..
O p N tp
1 rn 1 •1-1 1owX )(_ rn m I'7 N Ln
\' rp1 $� rn �'bH3 X 3nO8tl Imo(' z rn ce4 4 p
I-'
O +I yy a o 2 _ Onto. i1-213n31I1Ntl� "l'V W X X J
± o+ w ,.00x01 00'0Z 80 0 00'IS oow
onOS'fl n N0aod J� - I,ri 0
LJ Y N,rj 1a3tl3n0 1 IU LL.I Irn�
Q Q O rn �, 0.11 X1 o, c Jai .
} m o (llV1S f) OS'LI M o �o m co ? rn
0 3JVaV0 w p m0 1 ° a0� rn 0
�}` o v rn 0 0 rn UO CO o X W
Cl I z �LLo61 o �}za� x� ow w > >- ❑
E o Io ° z o m 0 m Z
W C� 00'LI 1N31N3SV8 1f10N001- 1cn Sn c0 2 0 E- O a ❑ Q
M n Q W U)
" J `^° , e CO rn 3SnoH w I,mp o o EQQ- w ~ a ❑ C[ J_
m Z o n a 1 salves/m o(0 03S0d0ad 3jl IJ o'- rn z at �I O Z Z a Q J fl Q Q a :,-z
r rn CC J Z Q
`�) °i �IJiiOd N3383s `no 3lB 10'6681 pr---J X.r X W
bI )£'668 H r'\ N < Z W 0 JZ = O a ❑
Cifj x/ 00'£b
m ‘(},--—4-•-T X r Q Z a 0 m
L rx O r� b0'Lz I I NO3a I m 90.'01 v1 J 2 i5 ❑ O F o g 0
�I� t i(,e*,e)IL W.
T67061- z o r` W Q Q W Q Uj CC
Q o� X�� 3A08Y ;N0V813S rn \o W 0 r` � � � ? ZOUO � � WO- CD j
N ceN
at �( a3n3iIiNv�,z-ONI01If18 ,SLJ n 1 moo' rn I c�7 O 0 U) O F- J W
�rn m la,\‘ I if, -t-� ci m H N r _ C• co f 2 _ LT a — ICC
4'4 CN
X�b l06o rn m �O W0 Z (h0 EE„, - < Z ❑ `J u.) J pH WU)
N-- NOV813S >1030X-----1,g1 1-7
In
Xi X x ^j ❑ o Lija C3 Z Q H W p O Z O
® �� S rn rn IS Q' � Qm2 cc
(n � LLpZU mF-
wQ
W 21333f18 ONV113M r, Om .. O 2Z 0
r • } uWj U Z Wp (/) ❑W H OLIIZ �
LI-
-x, I--�_� J JE- w2 v1 W n z
n
J
7b ----- .
r LI
o X m '� O ❑ >- LLI EE 0 UJ 5 El h3
pZp W ppm W CC W W -J 0_
C rn x o O ZOZZ O V) W -' CO mO ❑ > Q 0 (000)
E z cn
X go3O
O \ rnCL 71 CL CD
N M 7
O o co
a,
Z (.:3 pit c., ,
T• X
Oco
m 75. �oT1N '
� m'..,.,..
co
"y V 113- `
1C�
' �J \\\II`
.12
W
z0'
y a II LL .
•
3= F- 1- v, oNco00
ct co a W W u co 0 ai m 0
CC c\I 1 0 rn °m co rn cn
Y 0 � (�j^ � u) CO II II 11 II 11 =
cr) vs
O 0 QI- II tLO C\I pN W Eti r
0 • h LISCC u) < II 11 II
O V O
ZCO CD6.4 CC
,
E 0 0M� w W °o � fT
h o� , JQ ¢ c II H � 01 ^y ~O6
tc tc M Er+ 4 O c• U N 'TI V p p g Q o O 1-1-1
Z O'
b � Q q --•g), (�/) ,I= L7)
L.,-.1 � QoF J ❑ ooh Qo
O n 11 U) Z � 2Q 0OW O W O
1.11.11 (7 '� o � 2 '1 Qo9ZUW OJZ2 c �
W q 0 O ¢ amoa ❑ Oa ¢CD WWcc Ow
1:4u) � Q W = W
6.4 OJ � Q' a�iw N C) � OQQpw
J — a E- C'3mJ ¢ Cq � Q
0.1-4 tis
114
f,„,..N.,,[4. 1CO
iii
6
ma
1-
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA143599
Date Issued:06/20/2017
Permit Category:ePermit
Site Address: 3787 Wescott Cir
Lot:8 Block: 1 Addition: Willow Ridge At Wescott
PID:10-84435-01-080
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Water Softener
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Allow an 18" minimum radius clearance to the water meter from all appliances (i.e. furnace, water heater, water softener).
Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Gonyea Homes Inc
1000 Boone Ave Ste 400
Golden Valley MN 55427
Water Doctors Water Treatment Company
8201 Old Central Ave, Suite F & G
Spring Lake Park MN 55432
(763) 535-1800
Applicant/Permitee: Signature Issued By: Signature
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA146315
Date Issued:10/19/2017
Permit Category:ePermit
Site Address: 3787 Wescott Cir
Lot:8 Block: 1 Addition: Willow Ridge At Wescott
PID:10-84435-01-080
Use:
Description:
Sub Type:Residential
Work Type:Underground Sprinkler System
Description:PVB
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Fee Summary:PL - RPZ/PVB/Lawn Irrigation $59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Gonyea Homes Inc
1000 Boone Ave Ste 400
Golden Valley MN 55427
Sabre Plumbing Heating & A/c Inc
15535 Medina Road
Plymouth MN 55447
(763) 473-2267
Applicant/Permitee: Signature Issued By: Signature
City of Eag,all
Address: 3787 Wescott Circle Permit#: 142615
The following items were /were not completed at the Final Inspection on: / < 3 / ,- I
Complete Incomplete Comments
Final grade - 6"from siding 1r, 121(e /
Permanent steps — Garage
Permanent steps — Main Entry
Permanent Driveway V
Permanent Gas
Retaining Wall or 3:1 Max Slope ✓- `/zQ)/f +�
Sod I Seeded Lawn 57Z5// Y
Trail ! Curb Damage t�
Porch
Lower Level Finish
Deck t/
Fireplace q /I)41J
• Verify with your builder that roof test caps from the plumbing system have been removed.
• Turn off water supply to the outside lawn faucets before freeze potential exists.
• Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an
irrigation system.
Building Inspector: ( Imo-/