2017 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 12/10/2017 site Address: 1816 Ellie Ct Unit#:
Name: Han and Muna Javed Phone: 678-622-5153
Resident/ 17684 GlasgowWay, Lakeville, MN 55044
Owner Address/City/Zip: (j/�
Applicant is: Owner X Contractor Lb f S 81K 1 i`�J
Type of Work
Description of work: New Single Family Construction u V tJ vi `w z'rid s
Construction Cost: 635,500 Multi-Family Building:(Yes /No X )
Company: Sustainable 9 Design + Build Contact: Vince Birdsley-Project Manager
Address: 3302 W 44th St
City:Contractor
Minneapolis
MN 55410 Vince-952-250-8869 Vince@sustainable9.com
State: Zip: Phone: Ceti
Email:
License#: BC653457 Lead Certificate#. NAT-118432-1
If the project is exempt from lead certification, please explain why:
Empty Lot, New Construction
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan?
Yes X No If yes,date and address of master plan:
Licensed Plumber: Spring Plumbing LLC Phone: 763-614-7963
Mechanical Contractor: Perfection Heating & Air Cond Phone: 612-328-3512
Sewer&Water Contractor: Coppin Sewer & Water Phone: (952) 955-1588
Fire Suppression Contractor: Phone:
NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe
classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets.
You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's
website at www.cityofeagan.com/subscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit issuance.
CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.gopherstateonecall.org
I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in
accordance with the approved plan in the case of work which requires a review and approl
Digitally signed by Ryan Hanson
DN:cn=Ryan Hanson,o,ou,
Ryan Hanson-Owner-Sustainable 9 Design+Build —""" email=ryanhanson@sustainable9.com,c=US
x x Date:2016.02.06 17:56:02-06'00'
Applicant's Printed Name A scan ' a ure
Page 1 of 3
t/
1c61 (49 Enf Li / iij
DO NOT WRITE BELOW THIS LINE
),
SUB TYPES
Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family)
ZC Single Family _ Garage — Porch(4-Season) _ Exterior Alteration(Multi)
Multi _ Deck — Porch(Screen/Gazebo/Pergola) _ Miscellaneous
01 of_Plex _ Lower Level _ Pool _ Accessory Building
WORK TYPES
pNew _ Interior Improvement _ Siding _ Demolish Building*
Addition Move Building _ Reroof _ Demolish Interior
Alteration _ Fire Repair _ Windows _ Demolish Foundation
Replace _ Repair _ Egress Window _ Water Damage
Retaining Wall *Demolition of entire building-give PCA handout to applicant
DESCRIPTION
Valuation t $21/ S20• if Occupancy , ?Z C H MCES System
Plan Review Code Edition Unit ZIS SAC Units
(25%_100% X ) Zoning ( - ' City Water
Census Code Stories Booster Pump
#of Units Square Feet PRV
#of Buildings Length Fire Suppression Required
Type of Construction \113., Width
REQUIRED INSPECTIONS
.). Footings(New Building) Meter Size:
X Footings(Deck) Final I C.O. Required
Footings (Addition) Final I No C.O. Required
')C Foundation x Foundation Before Backfill HVAC_Gas Service Test Gas Line Air Test
r.> Roof:?`Ice &Water 'IC Final Pool: Footings Air/Gas Tests Final
( Framing 30 Minutes ? 1 Hour b a/i.$) Drain Tile
)o Fireplace: p Rough In (Air Test X Final Siding: Stucco Lath Stone Lath Brick EFIS
>4 Insulation Windows
y.) Sheathing )c Retaining Wall: > Footings 1c Backfill X Final
k, Sheetrock >1 Radon Control
Fire Walls Fire Suppression: Rough In Final
/0 Braced Walls Erosion Control
Shower Pan Other:
Reviewed By: T o er\ /Y 0 ')-1 P.- , Building Inspector
RESIDENTIAL FEES 6-fig-A9 e 6S i s y • `I'' 4 I
Base Fee 2.e.4, ra. I eae 1 12 bo 54 , /%?" r' 9s•, 3
Surcharge
101,4:41z-/oot-- / S1/ 3 J9 - fir `r qS•?3
Plan Review
MCES SAC
Z. '17? icIQ�tZ ZZ91-5,e /4r 6) .S•?3
`7
City SAC D e t k-S G 4 R I eeti e l 3 `/ a 54. /-r & 1 S:"'o
Utility Connection Charge
�.,�el aR- level �"' % 59• r g'-'":'
S&W Permit&Surcharge L_owB1L (eat] 0nrr.4;5he7 $6 51- 7--,O, /6-56
Treatment Plant
Copies )( ,D4'
TOTAL
Page 2 of 3
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution Date Certificate Post
panel.
Mailing Address of the Dwelling or Dwelling Unit City
1R1R lie—00414Contractor
'1��c: C24 - Eagan
Name of Residential Contractor MN License Number
Sustainable 9 Design+ Build BC653457
THERMAL ENVELOPE RADON CONTROL SYSTEM
Type:Check All That Apply X Passive(No Fan)
mt,uve tvvnrr Idrr dnu mur,urneier
o c or other system monitoring
HT ar N Location(or future location)of Fan:
Q T
2 c N m a w Any future fan located in atic
Q in m y U
> 0 V
c
w c 2mr
o z 2 O- w
Insulation Location c" $ rn E To 00-0 A
c 2) 2)
z Li u_ LL u- 2 b a Other Please Describe Here
Below Entire Slab 10 X
Foundation Wall 25 X X
Perimeter of Slab on Grade
Rim Joist(1st Floor) 21 X
Rim Joist(2nd Floor+) 21 X
Wall 21 X
Ceiling,flat 50 X
Ceiling,vaulted
Bay Windows or cantilevered areas 32 X
Floors over unconditioned area 32 X
Describe other insulated areas
Building envelope air tightness: Duct system air tightness:
Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces
Average U-Factor(excludes skylights and one door)U: .29 X Not applicable,all ducts located in conditioned space
Solar Heat Gain Coefficient(SHGC): 33 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System Domestic Water Cooling System
Heater x Not required per mech.code
Fuel Type Gas Gas Electric Passive
Manufacturer Carrier Rheem Carrier Powered
Interlocked with exhaust device.
Model 59TP6AXG5OT06PV42U0 24ABB336 Describe:
Input in 80000 Capacity in Output 3 Other,describe:
Rating or Size BTUS: Gallons: 80 in Tons:
AFUE or 96.6: SEER 13 Location of duct or system:
Efficiency HSPF°/a 0.67 energy factor /EER
Heating Loss Heating Gain Cooling Load N/A
Residential Load Calculatic 60621 27445 31666
Cf m's
"round duct OR
MECHANICAL VENTILATION SYSTEM "metal duct
Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type
source heat pump with gas back-up furnace): Not required per mech.code
Select Type x Passive
x Heat Recover Ventilator(HRV) Capacity in cfms: Low: 76 High: 190 Other,describe:
Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system:
Balanced Ventilation capacity in cfms: mech Room
Location of fan(s),describe: Cfm's
Capacity continuous ventilation rate in cfms: 6" "round duct OR
Total ventilation(intermittent+continuous)rate in cfms: "metal duct
Builders Associaton of Minnesota version 101014
1346.6012 IFGC APPENDIX EWORKSHEET E-1.
IF GCAppendix E.VNortohee E-1
Residential Combustion Air Calculation Method
(for FBoiler and/or Water Heater in the Same Space)
Step 1: Complete vented nombutinooppUoneinformation:
Fumume/BmUac `/ L�m/ D
Draft Hood Fan Assisted y Direct Btu/1'1r
|nputx��»` �tu/1'1r
(NotMVnAunistod) &Power Vent
Water Heater / FanAu»n�� DirectV*»� \nput//h8`� Bb�hr
Draft Hood �� �u» __- ' ' (
( Not fan Assisted) ` &Power Vent
$�p2 Co|ou|�mthe vo�moof the CombushonAp��noeSpace(CAS)oon�in|ng:ombuo�mmppaonmoo.
The CAS imdudesol spaces connected to oanothovhy#dmcomp\iantopmningo. CASvolumnr ft3
_ - --
Step Determine air Changes per Hour(AC H)'
Default ACH values have been incorporated into Table E 1 for use with Method 4b(KAIR Method) If the year of construction
or ACM is not known,use method 4a(Standard Method).
Step 4 Determine Required Volume for Combustion Air.
4a. Standard Method ��^�,
TWo|BKu/h,input nfoUmmnbuodonappliances(DO NOT COUNT DIRECT VENT APPLIANCES)Input/'� Btu/hr
Use Standard Method column in Table E-1 to find Total Required Volume(TRV) TRV:X•- 0 ft3
If CAS Volume(from Step 2)is greater Ow TRV then no outdoor openings are needed.
If CAS Volume(from Step 2)15 less Uiai TRV then go to STE P6
ifo. Known Air Infiltration Rate(KAIR)Method
Total Btuthrinpot of all fanassisted and power vent appliances
(DO NOT COUNT DIRECT VENT APPLIANCES) InputBtu/n,
Use Fan-Assisted Appliances column in Table E-1 to find
Required Volume Fan Assisted(RVFA) RVFA: ft3
Total Btu/hr input of all non fan assisted appliances Input Btu/hr
Use Non Fan Assisted Appliances column in Table£ 1 to find
Required Volume Non Fan Assisted(RVNFA) RVNFA: fp
Total Required Volume(TRV)=RVFA+RVNFA TRV= + =__-ft3
If CAS Volume(from Step 2)is gmalvr thaTRV then no outdoor openings are needed
If CAS Volume(from Step 2)15 less than TRV then qo to STEP 5.
Step Calculate the ratio of available interior volume to the total required volume 4134 xe,^' CM_ �?
Ratio=CAS VolumeCAS Volume(from Step 2)divided byTRV(from Step 4a or Step 4b) Ratio= / =-_
Step 6 Calculate Reduction Factor(RF)
Rp=1trims Ratio RF=1'_���___~�,'�w�
Step 7: Calculate single outdoor opening as if all combustion air is from outside �ty��� ^/h
To�|Bh/hrinput n[mUCnmbuoUonAppliances�� (EXCEPT ,-, puw ,
Combustion Air O | Area x/o,e" /�� �
' ~ ' � CAOA /30008�8nerin,= ~°~^�n'
Total � 3OOOB��,,e,�z = ^ ' |
Sa �ok�|�a��hnumOAOA.
~�
Minimum CAOA=OADA multiplied~'RF Mimimum CAOA=) x ~ ' �^
in2
Step 9 Calculate Combustion Air Opening Diameter(CAOD) ;I�
CAOD=1.13on��� the CAJD=1.13x�W|n�mmCA[�. ! n
I desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section 304.
Page 3 of 5
Table 501.31
Procedure to Determine tvbkeup Air Quantity for Exhaust Equipment in Dwellings
Use the Appropriate Column to Estimate House Infiltration
T One or multiple power vent One or multiple fan- One atmospherically Multiple atmospherically
or direct vent appliances or assisted appliances and vented gas or oil vented gas or oil
no combustion appliancesA power vent or direct vent appliance or one solid appliances or solid fuel
appliances° fuel appliancec appliances°
la) pressure factor(cfm/sf) 0.15 0.09 0.06 0.03
b) conditioned floor area
(sf)(including
unfinished basements I/ 0
Estimated House
Infiltration(cfm): 7016
[lax 1bi
2. Exhaust Capacity
a) continuous exhaust-
only ventilation systems )
(cfm): (not applicable
to balanced ventilation
systems such as HRV)
b) clothes dryer 135 135 135 135
c) 80%of largest exhaust
I rating(cfm);(not
applicable if
recirculating system or
if powered makeup air
is electrically
interlocked and
matched to exhaust)
d) 80%of next largest
exhaust rating(cfm):
(not applicable if
recirculating system or
if powered makeup air
is electrically
interlocked and
matched to exhaust) not ap_plicable
Total Exhaust Capacity Li
(cfm):[2.3+2b+2c+2d1
3, Makeup Air
Requirement
a) Total Exhaust Capacity j
(from above)
b) Estimated House 1,20
Infiltration(from above)
Makeup Air Quantity
(cfm):[3a—311
(if value is negative,no (263-
makeup air is needed)
4. For Makeup Air
Opening Sizing,refer to /
Table 501.3.2
A Use this column if there are other than fan- sisted or atmospherically vented gas or oil appliances or if there are no combustion
appliances.
Use this column if there is one fan-assisted appliance per venting system.Other than atmospherically vented appliances may also be
included.
c Use this column if there is one atmospherically vented(other than fan assisted)gas or oil appliance per venting system or one solid fuel
appliance.
0 Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
Page 4 of 5
1816 Elie Court
HVAC Load Calculations
for
ElIELS1 (4441411
RHVACRESIDENTIAL,
HVAC LOADS
Prepared By:
Wednesday, February 28, 2018
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 2
Project Report
General Project Information
Project Title: 1816 Elie Court
Project Date: Wednesday, November 22, 2017
Design Data
Reference City: Minneapolis, Minnesota
Building Orientation: Front door faces North
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -15 -12.38 100% n/a 70 n/a
Summer: 89 73 47% 50% 75 34
Check Figures
Total Building Supply CFM: 1,286 CFM Per Square ft.: 0.268
Square ft. of Room Area: 4,801 Square ft. Per Ton: 1,819
Volume (ft3)of Cond. Space: 44,569
Building Loads
Total Heating Required Including Ventilation Air: 60,621 Btuh 60.621 MBH
Total Sensible Gain: 27,445 Btuh 87
Total Latent Gain: 4,221 Btuh 13 %
Total Cooling Required Including Ventilation Air: 31,666 Btuh 2.64 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
•
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C itik 1816 Elie Court
Maplewood,MN 55109 10 Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -15 -12.38 100% n/a 70 n/a
Summer: 89 73 47% 50% 75 33.54
Duct Sizing Inputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration Specified: 0.100 AC/hr 0.050 AC/hr
56 CFM 28 CFM
Infiltration Actual: 0.100 AC/hr 0.050 AC/hr
Above Grade Volume: X 33.625 Cu.ft. X 33.625 Cu.ft.
3,363 Cu.ft./hr 1,681 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 56 CFM 28 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration &Ventilation Sensible Gain Multiplier: 14.94 = (1.10 X 0.970 X 14.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 22.13 = (0.68 X 0.970 X 33.54 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 90.72 = (1.10 X 0.970 X 85.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.100 AC/hr(56 CFM), Construction: Tight
Summer Infiltration Specified: 0.050 AC/hr(28 CFM), Construction: Tight
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads ® Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 4
Load Preview Report
Net ft? Sen; Lat Net Send Ht Sys SCI s Sys
Act Duct
Scope Ton /Ton Area Gain Gain• Gain Lost CFM CFM CFM Size
Building 2.64 1,819 4,801 27,445 4,221 31,666 60,621 811 1,286 1,286
System 1 2.64 1,819 4,801 27,445 4,221 31,666 60,621 811 1,286 1,286 12x18
Zone 1 4,801 27,445 4,221 31,666 60,621 811 1,286 1,286 12x18
1-Basement 1,368 964 47 1,011 8,825 118 45 45 1--4
2-Mudroom 100 1,237 41 1,278 2,611 35 58 58 1--4
3-Porch 180 3,091 40 3,131 5,789 77 145 145 1--7
4-Foyer 350 2,428 60 2,488 4,759 64 114 114 1--6
5-Great Room 594 4,336 64 4,400 8,092 108 203 203 2--6
6-Kitchen 253 2,433 64 2,497 4,363 58 114 114 1--6
7-Bedroom 1 240 1,297 246 1,543 3,058 41 61 61 1--4
8-Bath 1 &2 150 415 9 424 919 12 19 19 1--4
9-Bedroom 2 264 1,146 217 1,363 1,888 25 54 54 1--4
10-Family Room 378 996 40 1,036 2,745 37 47 47 1--4
11-MasterBa1h 149 658 35 693 2,123 28 31 31 1--4
12-Master Closet 121 467 31 498 1,874 25 22 22 1--4
13-Master Bedroom 252 1,918 438 2,356 4,374 59 90 90 1--6
14-Office 168 1,975 36 2,011 3,885 52 93 93 1--6
15-Laundry 90 811 1,227 2,038 1,924 26 38 38 1--4
16Stairs 144 3,273 1,626 4,899 3,392 45 153 153 1--7
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 5
Duct Size Preview
Room or Minimum Maximum Rough Design SP! Duct Duct Htg Clg Act. Duct
Duct Name Velocity Velocity Factor U100t Losse Velocity Lengtri Flow Flow j Flow Size
System 1
Supply Runouts
Zone 1
1-Basement 450 750 0 0.1 517.5 1181::, 1 45 1--4
2-Mud room 450 750 0 0.1 664.1 351 4 58 1--4
3-Porch 450 750 0 0.1 541.9 771, 145 145 1--7
4-Foyer 450 750 0 0.1 579.3 641;. 114 114 1--6
5-Great Room 450 750 0 0.1 517.3 1081, 203 203 2--6
6-Kitchen 450 750 0 0.1 580.5 58® 114 114 1--6
7-Bedroom 1 450 750 0 0.1 696.3 411 61 61 1--4
8-Bath 1&2 450 750 0 0.1 222.8 121 19 19 1--4
9-Bedroom 2 450 750 0 0.1 615.2 25 54 54 1--4
10-Family Room 450 750 0 0.1 534.7 37 47 47 1--4
11-Master Bath 450 750 0 0.1 353.3 28 31 31 1--4
12-Master Closet 450 750 0 0.1 250.7 25 22 22 1--4
13-Master Bedroom 450 750 0 0.1 457.6 59 90 90 1--6
14-Office 450 750 0 0.1 471.2 52 93 93 1--6
15-Laundry 450 750 0 0.1 435.4 26 38 38 1--4
16Stairs 450 750 0 0.1 573.8 45 153 153 1--7
Other Ducts
Supply Main Trunk 650 900 0 0.1 857.2 811_ 1,286 12x18
Summary
System 1
Heating Flow: 811
Cooling Flow: 1286
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 6
System 1 - - Adequate Exposure Diversity Test
Test For Adequate Exposure Diversity
40,000
30,000-
- . 0. Ir. •u i a
w
m —
c
20,000
ca
a�
10,000
0
8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm
/ Average Glass / 1.3 x Average / Hourly Glass Gain / Hourly Total Net
Sensible Gain Glass Gain Gain
Over 12 Hours
AED Calculation Summary
--- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. ---
System is on N, E, S, W rosette.
Peak load exceeds 12-hour average load by 24.5%.
AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh
Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not
exceed the average glass load for the entire conditioned space by more than 30 percent.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 7
System I - Psychrometric Chart
ZC Zone(Room)Condition OC Outdoor Condition
LC Leaving Coil Condition EC Entering Coil Condition
SD Supply Duct Temperature Rise DTF Draw Through Fan Sensible Gain
HRV Heat Recovery Ventilator
-4 zc
7/1\ 'Ni
/-2?"-n---' 7 -,. .-
f rf -
/ jV
am '- 1
<--.7:00.7)0 e 5
� ...focr„ _ ),,,,,,' M1 >Ji .
f
1- -.
� '~ `^. .
� .. - r 42
-- l
.N. 28
-- -- r --- P-
y ~ ti
- W r{1l' vim ` \
'+,,��. \1 ' ". '^w ill 1
S
c0
s
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 8
Project Bill of Materials
Unit Unit
Uni
Part No. Description Req' Qty. Matl Matl Shop Field Lobos Tota
Qty. Unit Cost Labor Labor Cost
Cos ,Hours Hours Cost
Ductwork Accessories
Subtotal-Ductwork Accessories $0.00 $0.00 $0.00
HVAC Equipment
Subtotal-HVAC Equipment $0.00 $0.00 $0.00
Grand Total $0.00 $0.00 $0.00
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
•
• Rhvac-Residential&Light Commercial HVAC Loads T.
Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 9
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
w1: Glazing-new construction window, u-value 0.35, 989.7 29,446 0 17,866 17,866
SHGC 0.32
5w1: Glazing- 15 446 0 522 522
15A21-Ofcm-10: Wall-Basement, , framing with R-21 sill 1196 4,473 0 0 0
to floor in 2 x 6 cavity, filled core, no board insulation,
plus interior finish, metal studs, 10'floor depth
13FA-Ofcw: Wall-Block, framing with R-21 in 2 x6 stud 267 1,384 0 156 156
cavity, filled core,wood studs
12D1-0sw: Wall-Frame, R-21 closed cell 2 lb. spray foam 235.8 1,523 0 331 331
insulation in 2 x 4 stud cavity, no board insulation,
siding finish,wood studs
12F-Osw: Wall-Frame, R-21 insulation in 2 x6 stud cavity, 1200.5 6,633 0 1,116 1,116
no board insulation, siding finish, wood studs
12E-Osw: Wall-Frame, R-19 insulation in 2 x6 stud cavity, 1213.5 7,012 0 1,352 1,352
no board insulation, siding finish,wood studs
16B-56: Roof/Ceiling-Under Attic with Insulation on Attic 1955 2,991 0 1,724 1,724
Floor(also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, Dark Asphalt
Shingles or Dark Metal, Tar and Gravel or
Membrane, R-56 insulation
216-32: Floor-Basement, Concrete slab, any thickness, 2 1368 1,628 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 32'wide
Subtotals for structure: 55,536 0 23,067 23,067
People: 12 2,400 2,760 5,160
Equipment: 1,200 1,200 2,400
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 56, Summer CFM: 28 5,085 621 418 1,039
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Total Building Load Totals: 60,621 4,221 27,445 31,666
Check Figures
Total Building Supply CFM: 1,286 CFM Per Square ft.: 0.268
Square ft. of Room Area: 4,801 Square ft. Per Ton: 1,819
Volume(ft3)of Cond. Space: 44,569
Building Loads
Total Heating Required Including Ventilation Air: 60,621 Btuh 60.621 MBH
Total Sensible Gain: 27,445 Btuh 87 %
Total Latent Gain: 4,221 Btuh 13 %
Total Cooling Required Including Ventilation Air: 31,666 Btuh 2.64 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 10
Building Pie Chart
Floor 3%
Roof 5% Infiltration 8%
Building
Loss Wall 35%
60,621
Btuh
Glass 49%
Roof 5% Infiltration3%/EuiPment 8%
Wall 9'3/0
People 16%
Building
Gain
31,666
Btuh
Glass 58%
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/Clir 1816 Elie Court
Maplewood,MN 55109 Page 11
Building Bar Graph
30,000
25,000
20,000
Building 15,000
Loss
60,621
Btuh 10,000
4 \
5,000
0
/ I
Floor 3% Wall 35% Infiltration 8%
Roof 5% Glass 49%
20,000 --\
15,000
Building 10,000
Gain
31,666
Btuh
5,000
0 am,„
Roof 5% Glass 58% Equipment 8%
Wall 9% People 16% Infiltration 3%
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 12
System 1 Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
w1: Glazing-new construction window, u-value 0.35, 989.7 29,446 0 17,866 17,866
SHGC 0.32
5w1: Glazing- 15 446 0 522 522
15A21-Ofcm-10: Wall-Basement, ,framing with R-21 sill 1196 4,473 0 0 0
to floor in 2 x 6 cavity, filled core, no board insulation,
plus interior finish, metal studs, 10'floor depth
13FA-Ofcw: Wall-Block,framing with R-21 in 2 x6 stud 267 1,384 0 156 156
cavity, filled core, wood studs
12D1-0sw:Wall-Frame, R-21 closed cell 2 lb. spray foam 235.8 1,523 0 331 331
insulation in 2 x 4 stud cavity, no board insulation,
siding finish,wood studs
12F-Osw:Wall-Frame, R-21 insulation in 2 x6 stud cavity, 1200.5 6,633 0 1,116 1,116
no board insulation, siding finish,wood studs
12E-Osw: Wall-Frame, R-19 insulation in 2 x6 stud cavity, 1213.5 7,012 0 1,352 1,352
no board insulation, siding finish,wood studs
16B-56: Roof/Ceiling-Under Attic with Insulation on Attic 1955 2,991 0 1,724 1,724
Floor(also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, Dark Asphalt
Shingles or Dark Metal, Tar and Gravel or
Membrane, R-56 insulation
21 B-32: Floor-Basement, Concrete slab, any thickness, 2 1368 1,628 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 32'wide
Subtotals for structure: 55,536 0 23,067 23,067
People: 12 2,400 2,760 5,160
Equipment: 1,200 1,200 2,400
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 56, Summer CFM: 28 5,085 621 418 1,039
Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0
System 1 Load Totals: 60,621 4,221 27,445 31,666
Check Figures
Supply CFM: 1,286 CFM Per Square ft.: 0.268
Square ft. of Room Area: 4,801 Square ft. Per Ton: 1,819
Volume (ft3)of Cond. Space: 44,569
System Loads
Total Heating Required Including Ventilation Air: 60,621 Btuh 60.621 MBH
Total Sensible Gain: 27,445 Btuh 87 %
Total Latent Gain: 4,221 Btuh 13 %
Total Cooling Required Including Ventilation Air: 31,666 Btuh 2.64 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 13
System I Pie Chart
Floor 3%
Roof 5% Infiltration 8%
System
1 Wall 35%
Loss
60,621
Btuh
Glass 49%
Roof 5% Infiltration 3%E
8%
Wall 9%
People 16%
System
1
Gain
31 ,666
Btuh
Glass 58%
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 14
System I Bar Graph
30,000
25,000
20,000
System
1 15,000
Loss
60,621 10,000
Btu h
5,000
I l
0
Floor 3% Wall 35% Infiltration 8%
Roof 5% Glass 49%
20,000
15,000
System
1 10,000
Gain
31 ,666
Btuh 5,000
0
Roof 5% Glass 58% Equipment 8%
Wall 9% People 16% Infiltration 3%
C:\Users\JHopkWppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
•
•
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C S 1816 Elie Court
Maplewood,MN 55109 Page 15
System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms)
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
w1: Glazing-new construction window, u-value 0.35, 989.7 29,446 0 17,866 17,866
SHGC 0.32
5w1: Glazing- 15 446 0 522 522
15A21-Ofcm-10: Wall-Basement, , framing with R-21 sill 1196 4,473 0 0 0
to floor in 2 x 6 cavity, filled core, no board insulation,
plus interior finish, metal studs, 10'floor depth
13FA-Ofcw: Wall-Block, framing with R-21 in 2 x6 stud 267 1,384 0 156 156
cavity, filled core, wood studs
12D1-0sw: Wall-Frame, R-21 closed cell 2 lb. spray foam 235.8 1,523 0 331 331
insulation in 2 x 4 stud cavity, no board insulation,
siding finish, wood studs
12F-Osw: Wall-Frame, R-21 insulation in 2 x6 stud cavity, 1200.5 6,633 0 1,116 1,116
no board insulation, siding finish, wood studs
12E-Osw: Wall-Frame, R-19 insulation in 2 x6 stud cavity, 1213.5 7,012 0 1,352 1,352
no board insulation, siding finish, wood studs
16B-56: Roof/Ceiling-Under Attic with Insulation on Attic 1955 2,991 0 1,724 1,724
Floor(also use for Knee Walls and Partition Ceilings),
Vented Attic, No Radiant Barrier, Dark Asphalt
Shingles or Dark Metal, Tar and Gravel or
Membrane, R-56 insulation
21B-32: Floor-Basement, Concrete slab, any thickness, 2 1368 1,628 0 0 0
or more feet below grade, R-3 or higher insulation
installed below floor, any floor cover, shortest side of
floor slab is 32'wide
Subtotals for structure: 55,536 0 23,067 23,067
People: 12 2,400 2,760 5,160
Equipment: 1,200 1,200 2,400
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 56, Summer CFM: 28 5,085 621 418 1,039
System 1, Zone 1 Load Totals: 60,621 4,221 27,445 31,666
Check Figures
Supply CFM: 1,286 CFM Per Square ft.: 0.268
Square ft. of Room Area: 4,801 Square ft. Per Ton: 1,819
Volume (ft3) of Cond. Space: 44,569
Zone Loads
Total Heating Required: 60,621 Btuh 60.621 MBH
Total Sensible Gain: 27,445 Btuh 87 %
Total Latent Gain: 4,221 Btuh 13
Total Cooling Required: 31,666 Btuh 2.64 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
•
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 16
System 1, Zone 1 Pie Chart
Floor 3%
Roof 5% Infiltration 8%
System
1 , Zone
1 Wall 35%
Loss
60,621
Btuh
Glass 49%
Roof 5% Infiltration 3%E 8%
Wall 9%
S stem PeoPle 16%
y �
1 , Zone
1
Gain
31 ,666
Btuh
Glass 58%
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C s 1816 Elie Court
Maplewood,MN 55109 Page 17
System 1, Zone 1 Bar Graph
30,000
25,000
20,000
System
1 , Zone 15,000
1
Loss
60,621 10,000
Btuh
5,000
0
1 l
Floor 3% Wall 35% Infiltration 8%
Roof 5% Glass 49%
20,000
15,000
System
1 , Zone 10,000
1
Gain
31 ,666
Btuh 5,000
0
Roof 5% Glass 58% Equipment 8%
Wall 9% People 16% Infiltration 3%
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 18
Detailed Room Loads - Room 1 - Basement (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 36.0 ft. System Number: 1
Room Width: 38.0 ft. Zone Number: 1
Area: 1,368.0 sq.ft. Supply Air: 45 CFM
Ceiling Height: 10.0 ft. Supply Air Changes: 0.2 AC/hr
Volume: 13,680.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 45 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 518 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 518 ft./min. Actual Winter Infil.: 4 CFM
Actual Loss: 0.294 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-15A21-Ofcm-10 149.5 X 8 1196 0.044 3.7 4,473 0.0 0 0
NE-Wall-13FA-Ofcw 149.5 X 2 267 0.061 5.2 1,384 0.6 0 156
NE-GIs-w1 shgc-0.32 0%S(2) 32 0.350 29.8 952 24.3 0 776
Floor-21B-3238X36 1368 0.014 1.2 1,628 0.0 0 0
Subtotals for Structure: 8,437 0 932
Infil.: Win.: 4.3, Sum.: 2.1 299 1.298 388 0.107 47 32
Room Totals: 8,825 47 964
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 19
Detailed Room Loads - Room 2 - Mudroom (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 10.0 ft. System Number: 1
Room Width: 10.0 ft. Zone Number: 1
Area: 100.0 sq.ft. Supply Air: 58 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 3.9 AC/hr
Volume: 900.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 58 CFM Percent of Supply.: 0
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 664 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 664 ft./min. Actual Winter Infil.: 4 CFM
Actual Loss: 0.481 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12D1-0sw 9.5 X 9 85.5 0.076 6.5 552 1.4 0 120
S -Wall-12D1-0sw 9.5 X 9 85.5 0.076 6.5 552 1.4 0 120
W -Wall-12D1-0sw 10 X 9 64.8 0.076 6.5 419 1.4 0 91
W -GIs-w1 shgc-0.32 0%S 12.6 0.350 29.8 375 34.8 0 439
W -GIs-w1 sh9c-0.32 0%S 12.6 0.350 29.8 375 34.8 0 439
Subtotals for Structure: 2,273 0 1,209
Infil.: Win.: 3.7, Sum.: 1.9 261 1.295 33.8 0.107 41 28
Room Totals: 2,611 41 1,237
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. .
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 20
Detailed Room Loads - Room 3 - Porch (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 12.0 ft. System Number: 1
Room Width: 15.0 ft. Zone Number: 1
Area: 180.0 sq.ft. Supply Air: 145 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 5.4 AC/hr
Volume: 1,620.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 145 CFM Percent of Supply.: 0 %
Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 542 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 542 ft./min. Actual Winter Infil.: 4 CFM
Actual Loss: 0.148 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12F-Osw 15 X 9 15 0.065 5.5 83 0.9 0 14
W -Wall-12F-Osw 5 X 9 21 0.065 5.5 116 0.9 0 20
E-Wall-12F-Osw 8 X 9 48 0.065 5.5 265 0.9 0 45
N -GIs-w1 shgc-0.32 100%S 120 0.350 29.8 3,570 11.0 0 1,315
W -GIs-w1 shgc-0.32 0%S 24 0.350 29.8 714 34.8 0 835
E-GIs-w1 shgc-0.32 0%S 24 0.350 29.8 714 34.8 0 835
Subtotals for Structure: 5,462 0 3,064
Infil.:Win.: 3.6, Sum.: 1.8 252 1.298 327 0.107 40 27
Room Totals: 5,789 40 3,091
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 21
Detailed Room Loads - Room 4 - Foyer (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 28.0 ft. System Number: 1
Room Width: 12.5 ft. Zone Number: 1
Area: 350.0 sq.ft. Supply Air: 114 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.2 AC/hr
Volume: 3,150.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 114 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 579 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 579 ft./min. Actual Winter Infil.: 5 CFM
Actual Loss: 0.208 in.wg./100 ft. Actual Summer Infil.: 3 CFM
Item Area -U- Htg Sen CIg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
W-Wall-12F-Osw 7 X 9 63 0.065 5.5 348 0.9 0 59
E-Wall-12F-0sw 22 X 9 174 0.065 5.5 961 0.9 0 162
S -Wall-12F-Osw 13 X 9 51 0.065 5.5 282 0.9 0 47
S -GIs-w1 shgc-0.32 0%S 18 0.350 29.8 536 19.4 0 350
S-GIs-w1 shgc-0.32 0%S 48 0.350 29.8 1,428 19.5 0 934
E-GIs-w1 shgc-0.32 0%S 12 0.350 29.8 357 34.8 0 418
E -GIs-w1 shgc-0.32 0%S 12 0.350 29.8 357 34.8 0 418
Subtotals for Structure: 4,269 0 2,388
Infil.: Win.: 5.4, Sum.: 2.7 378 1.296 490 0.106 60 40
Room Totals: 4,759 60 2,428
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 22
Detailed Room Loads - Room 5 - Great Room (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 33.0 ft. System Number: 1
Room Width: 18.0 ft. Zone Number: 1
Area: 594.0 sq.ft. Supply Air: 203 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.3 AC/hr
Volume: 5,346.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 2 Actual Winter Vent.: 0 CFM
Runout Air: 102 CFM Percent of Supply.: 0
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 517 ft./min. Percent of Supply: 0
Runout Air Velocity: 517 ft./min. Actual Winter Infil.: 6 CFM
Actual Loss: 0.167 in.wg./100 ft. Actual Summer Infil.: 3 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S -Wall-12F-Osw 18.5 X 9 122.5 0.065 5.5 677 0.9 0 114
N -Wall-12F-Osw 14.5 X 9 10.5 0.065 5.5 58 0.9 0 10
E-Wall-12F-Osw 8 X 9 44 0.065 5.5 243 0.9 0 41
W -Wall-12F-Osw 4 X 9 8 0.065 5.5 44 0.9 0 7
S-GIs-w1 shgc-0.32 0%S 44 0.350 29.8 1,309 19.5 0 856
N -GIs-w1 shgc-0.32 100%S 120 0.350 29.8 3,570 11.0 0 1,315
E-GIs-w1 shgc-0.32 0%S 28 0.350 29.8 833 34.8 0 975
W -GIs-w1 shgc-0.32 0%S 28 0.350 29.8 833 34.8 0 975
Subtotals for Structure: 7,567 0 4,293
Infil.: Win.: 5.8, Sum.: 2.9 405 1.296 525 0.106 64 43
Room Totals: 8,092 64 4,336
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
•
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 4114 1816 Elie Court
Maplewood,MN 55109 r Page 23
Detailed Room Loads - Room 6 - Kitchen (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 23.0 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 253.0 sq.ft. Supply Air: 114 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 3.0 AC/hr
Volume: 2,277.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 114 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 581 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 581 ft./min. Actual Winter Infil.: 6 CFM
Actual Loss: 0.209 in.wg./100 ft. Actual Summer Infil.: 3 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S -Wall-12F-Osw 11 X 9 81 0.065 5.5 448 0.9 0 75
N -Wall-12F-Osw 11 X 9 51 0.065 5.5 282 0.9 0 47
E -Wall-12F-0sw 23 X 9 207 0.065 5.5 1,144 0.9 0 192
S -GIs-w1 shgc-0.32 0%S (2) 18 0.350 29.8 536 19.4 0 350
N -GIs-w1 shgc-0.32 100%S 48 0.350 29.8 1,428 11.0 0 526
Subtotals for Structure: 3,838 0 1,190
Infil.: Win.: 5.8, Sum.: 2.9 405 1.296 525 0.106 64 43
Equipment: 0 1,200
Room Totals: 4,363 64 2,433
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 24
Detailed Room Loads - Room 7 - Bedroom 1 (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 20.0 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 240.0 sq.ft. Supply Air: 61 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.7 AC/hr
Volume: 2,160.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 61 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 696 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 696 ft./min. Actual Winter Infil.: 4 CFM
Actual Loss: 0.528 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
W -Wall-12F-Osw 20 X 9 180 0.065 5.5 994 0.9 0 167
S-Wall-12F-Osw 12 X 9 78 0.065 5.5 431 0.9 0 73
S-GIs-w1 shgc-0.32 0%S 30 0.350 29.8 893 19.5 0 584
UP-Ceil-16B-56 20 X 12 2.4.0 0.018 1.5 367 0.9 0 212
Subtotals for Structure: 2,685 0 1,036
Infil.: Win.: 4.1, Sum.: 2.1 288 1.295 373 0.108 46 31
People: 200 lat/per, 23.0 sen/per: 1 200 230
Room Totals: 3,058 246 1,297
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 25
Detailed Room Loads - Room 8 - Bath 1 & 2 (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 23.0 ft. System Number: 1
Room Width: 6.5 ft. Zone Number: 1
Area: 150.0 sq.ft. Supply Air: 19 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 0.9 AC/hr
Volume: 1,346.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 19 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 223 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 223 ft./min. Actual Winter Infil.: 1 CFM
Actual Loss: 0.056 in.wg./100 ft. Actual Summer Infil.: 0 CFM
Item Area -U- Htg Sen CIg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S-Wall-12F-Osw 6.5 X 9 46.5 0.065 5.5 257 0.9 0 43
S-GIs-w1 shgc-0.32 0%S 12 0.350 29.8 357 19.5 0 234
UP-Ceil-16B-56 23 X 6.5 149.5 0.018 1.5 229 0.9 0 132
Subtotals for Structure: 843 0 409
Infil. Win.: 0.8, Sum.: 0.4 59 1.299 76 0.103 9 6
Room Totals: 919 9 415
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 26
Detailed Room Loads - Room 9 - Bedroom 2 (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 22.0 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 264.0 sq.ft. Supply Air: 54 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.4 AC/hr
Volume: 2,376.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 54 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 615 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 615 ft./min. Actual Winter Infil.: 2 CFM
Actual Loss: 0.414 in.wg./100 ft. Actual Summer Infil.: 1 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S -Wall-12E-Osw 12 X 9 78 0.068 5.8 451 1.1 0 87
S-GIs-w1 shgc-0.32 0%S 30 0.350 29.8 893 19.5 0 584
UP-Ceil-16B-56 22 X 12 264 0.018 1.5 404 0.9 0 233
Subtotals for Structure: 1,748 0 904
Infil.: Win.: 1.5, Sum.: 0.8 108 1.296 140 0.111 17 12
People: 200 lat/per, 230 sen/per: 1 200 230
Room Totals: 1,888 217 1,146
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
• Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C % 1816 Elie Court
Maplewood,MN 55109 60Page 27
Detailed Room Loads - Room 10 - Family Room (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 21.0 ft. System Number: 1
Room Width: 18.0 ft. Zone Number: 1
Area: 378.0 sq.ft. Supply Air: 47 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 0.8 AC/hr
Volume: 3,402.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 47 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 535 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 535 ft./min. Actual Winter Infil.: 4 CFM
Actual Loss: 0.314 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S-Wall-12E-Osw 18 X 9 150 0.068 5.8 867 1.1 0 167
W -Wall-12E-Osw 5.5 X 9 45.5 0.068 5.8 263 1.1 0 51
E -Wall-12E-Osw 4.5 X 9 40.5 0.068 5.8 234 1.1 0 45
S -GIs-w1 shgc-0.32 0%S 12 0.350 29.8 357 19.5 0 234
W -GIs-w1 shgc-0.32 0%S 4 0.350 29.8 119 34.8 0 139
UP-Ceil-16B-56 21 X 18 378 0.018 1.5 578 0.9 0 333
Subtotals for Structure: 2,418 0 969
Infil.: Win.: 3.6, Sum.: 1.8 252 1.298 327 0.107 40 27
Room Totals: 2,745 40 996
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 28
Detailed Room Loads - Room 11 - Master Bath (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 13.5 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 149.0 sq.ft. Supply Air: 31 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.4 AC/hr
Volume: 1,337.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 31 CFM Percent of Supply.: 0
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 353 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 353 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.139 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
S-Wall-12E-Osw 11 X 9 85 0.068 5.8 491 1.1 0 95
E-Wall-12E-Osw 13.5 X 9 121.5 0.068 5.8 702 1.1 0 135
S-GIs-w1 shgc-0.32 0%S 14 0.350 29.8 417 19.5 0 273
UP-Ceil-16B-56 13.5 X 11 148.5 0.018 1.5 227 0.9 0 131
Subtotals for Structure: 1,837 0 634
Infil.:Win.: 3.2, Sum.: 1.6 221 1.297 286 0.109 35 24
Room Totals: 2,123 35 658
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 29
Detailed Room Loads - Room 12 - Master Closet (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 11.0 ft. System Number: 1
Room Width: 11.0 ft. Zone Number: 1
Area: 121.0 sq.ft. Supply Air: 22 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 1.2 AC/hr
Volume: 1,089.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 22 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 251 ft./min. Percent of Supply: 0
Runout Air Velocity: 251 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.071 in.wg./100 ft. Actual Summer Infil.: 1 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
E -Wall-12E-Osw 11 X 9 99 0.068 5.8 572 1.1 0 110
N -Wall-12E-Osw 11 X 9 87 0.068 5.8 503 1.1 0 97
N -GIs-w1 shgc-0.32 100%S 12 0.350 29.8 357 11.0 0 132
UP-Ceil-16B-56 11 X 11 121 0.018 1.5 185 0.9 0 107
Subtotals for Structure: 1,617 0 446
Infil.: Win.: 2.8, Sum.: 1.4 198 1.298 257 0.106 31 21
Room Totals: 1,874 31 467
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 144. 1816 Elie Court
Maplewood,MN 55109 Page 30
Detailed Room Loads - Room 13 - Master Bedroom (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 14.0 ft. System Number: 1
Room Width: 18.0 ft. Zone Number: 1
Area: 252.0 sq.ft. Supply Air: 90 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr
Volume: 2,268.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 90 CFM Percent of Supply.: 0 %
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 458 ft./min. Percent of Supply: 0
Runout Air Velocity: 458 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.131 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12E-Osw 18 X 9 66 0.068 5.8 381 1.1 0 74
E -Wall-12E-Osw 6.5 X 9 58.5 0.068 5.8 338 1.1 0 65
W -Wall-12E-Osw 2 X 9 18 0.068 5.8 104 1.1 0 20
N -GIs-w1 shgc-0.32 100%S 96 0.350 29.8 2,856 11.0 0 1,052
UP-Ceil-16B-56 14 X 18 252 0.018 1.5 386 0.9 0 222
Subtotals for Structure: 4,065 0 1,433
Infil.: Win.: 3.4, Sum.: 1.7- 239 1.296 309 0.105 38 25
People: 200 lat/per, 230 sen/per: 2 400 460
Room Totals: 4,374 438 1,918
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
•
Perfection Heating and A/C 1816 Elie Court
ti
Maplewood,MN 55109 Page 31
Detailed Room Loads - Room 14 - Office (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 14.0 ft. System Number: 1
Room Width: 12.0 ft. Zone Number: 1
Area: 168.0 sq.ft. Supply Air: 93 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 3.7 AC/hr
Volume: 1,512.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 93 CFM Percent of Supply.: 0
Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 471 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 471 ft./min. Actual Winter Infil.: 3 CFM
Actual Loss: 0.139 in.wg./100 ft. Actual Summer Infil.: 2 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12E-Osw 12 X 9 53 0.068 5.8 306 1.1 0 59
E-Wall-12E-Osw 8 X 9 57 0.068 5.8 329 1.1 0 64
W -Wall-12E-Osw 5 X 9 30 0.068 5.8 173 1.1 0 33
N -GIs-w1 shgc-0.32 100%S 55 0.350 29.8 1,636 11.0 0 603
E -GIs-w1 shgc-0.32 0%S 15 0.350 29.8 446 34.8 0 522
W -GIs-5w1 shgc-0.32 0%S 15 0.350 29.8 446 34.8 0 522
UP-Ceii-16B-56 14 X 12 168 0.018 1.5 257 0.9 0 148
Subtotals for Structure: 3,593 0 1,951
Infil.:Win.: 3.2, Sum.: 1.6 225 1.298 292 0.107 36 24
Room Totals: 3,885 36 1,975
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. •
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 32
Detailed Room Loads - Room 15 - Laundry (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 9.0 ft. System Number: 1
Room Width: 10.0 ft. Zone Number: 1
Area: 90.0 sq.ft. Supply Air: 38 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 2.8 AC/hr
Volume: 810.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 38 CFM Percent of Supply.: 0 %
Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 435 ft./min. Percent of Supply: 0
Runout Air Velocity: 435 ft./min. Actual Winter Infil.: 2 CFM
Actual Loss: 0.209 in.wg./100 ft. Actual Summer Infil.: 1 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12E-Osw 10 X 9 78 0.068 5.8 451 1.1 0 87
W-Wall-12E-Osw 9 X 9 69 0.068 5.8 399 1.1 0 77
N -GIs-w1 shgc-0.32 100%S 12 0.350 29.8 357 11.0 0 132
W -GIs-w1 shgc-0.32 0%S 12 0.350 29.8 357 34.8 0 418
UP-Ceil-16B-56 9 X 10 90 0.018 1.5 138 0.9 0 79
Subtotals for Structure: 1,702 0 793
Infil.: Win.: 2.4, Sum.: 1.2 171 1.298 222 0.105 27 18
Equipment: 1,200 0
Room Totals: 1,924 1,227 811
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 33
Detailed Room Loads - Room 16 - Stairs (Average Load Procedure)
General
Calculation Mode: Htg. &clg. Occurrences: 1
Room Length: 16.0 ft. System Number: 1
Room Width: 9.0 ft. Zone Number: 1
Area: 144.0 sq.ft. Supply Air: 153 CFM
Ceiling Height: 9.0 ft. Supply Air Changes: 7.1 AC/hr
Volume: 1,296.0 cu.ft. Req. Vent. Clg: 0 CFM
Number of Registers: 1 Actual Winter Vent.: 0 CFM
Runout Air: 153 CFM Percent of Supply.: 0 %
Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM
Runout Air Velocity: 574 ft./min. Percent of Supply: 0 %
Runout Air Velocity: 574 ft./min. Actual Winter Infil.: 2 CFM
Actual Loss: 0.165 in.wg./100 ft. Actual Summer Infil.: 1 CFM
Item Area -U- Htg Sen Clg Lat Sen
Description Quantity Value HTM Loss HTM Gain Gain
N -Wall-12E-Osw 9 X 9 29 0.068 5.8 168 1.1 0 32
S -Wall-12E-Osw 9 X 9 48.5 0.068 5.8 280 1.1 0 54
N -GIs-w1 shgc-0.32 100%S 52 0.350 29.8 1,547 11.0 0 570
S -GIs-w1 shgc-0.32 0%S 32.5 0.350 29.8 967 19.5 0 633
UP-Ceil-16B-56 16 X 9 144 0.018 1.5 220 0.9 0 127
Subtotals for Structure: 3,182 0 1,416
Infil.: Win.: 2.3, Sum.: 1.2 162 1.296 210 0.105 26 17
People: 200 lat/per, 230 sen/per: 8 1,600 1,840
Room Totals: 3,392 1,626 3,273
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 34
Room Cooling and Heating Loads Bar Graphs
Basement
Mudroom
Cooling
Porch
Foyer
Great Room
Kitchen
Bedroom 1
Bath 1 &2
I Heating
Bedroom 2
Family Room
0 2,000 4,000 6,000 8,000 10,000
Btuh
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 35
Room Cooling and Heating Loads Bar Graphs
Master Bath
11 Cooling
Master Closet
Master Bedroom
Office
Laundry
Heating
Stairs
0 1,000 2,000 3,000 4,000 5,000
Btuh
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and NC 1816 Elie Court
Maplewood,MN 55109 Page 36
Room Cooling Loads Bar Graphs
Basement
Mudroom
• Sensible
Porch
Foyer
Great Room
Kitchen
Bedroom 1
Bath 1 &2
Latent
Bedroom 2
Family Room
0 1,000 2,000 3,000 4,000 5,000
Btuh
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 37
Room Cooling Loads Bar Graphs
Master Bath
I Sensible
Master Closet
Master Bedroom
Office
Laundry
I Latent
Stairs
0 1,000 2,000 3,000 4,000 5,000
Btuh
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads r Elite Software Development,Inc. -
Perfection Heating and A/C �P 1816 Elie Court
Maplewood,MN 55109 10 Page 38
System I Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Basement 1,368 8,825 118 1-4 518 964 47 45 45
2 Mudroom 100 2,611 35 1-4 664 1,237 41 58 58
3 Porch 180 5,789 77 1-7 542 3,091 40 145 145
4 Foyer 350 4,759 64 1-6 579 2,428 60 114 114
5 Great Room 594 8,092 108 2-6 517 4,336 64 203 203
6 Kitchen 253 4,363 58 1-6 581 2,433 64 114 114
7 Bedroom 1 240 3,058 41 1-4 696 1,297 246 61 61
8 Bath 1 &2 150 919 12 1-4 223 415 9 19 19
9 Bedroom 2 264 1,888 25 1-4 615 1,146 217 54 54
10 Family Room 378 2,745 37 1-4 535 996 40 47 47
11 Master Bath 149 2,123 28 1-4 353 658 35 31 31
12 Master Closet 121 1,874 25 1-4 251 467 31 22 22
13 Master Bedroom 252 4,374 59 1-6 458 1,918 438 90 90
14 Office 168 3,885 52 1-6 471 1,975 36 93 93
15 Laundry 90 1,924 26 1-4 435 811 1,227 38 38
16 Stairs 144 3,392 45 1-7 574 3,273 1,626 153 153
System 1 total 4,801 60,621 811 27,445 4,221 1,286 1,286
System 1 Main Trunk Size: 12x18 in.
Velocity: 857 ft./min
Loss per 100 ft.: 0.100 in.wg
Cooling System Summary
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 2.64 87%/ 13% 27,445 4,221 31,666
Equipment Data
Heating System Cooling System
Type: Natural Gas Furnace Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency: 0 AFUE 0 SEER
Sound:
Capacity: 0 Btuh 0 Btuh
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. -
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 tO1Page 40
Building Rotation Report
All rotation degree values in this report are clockwise with respect to the project's original orientation.
Building orientation as entered (zero degrees rotation): Front door faces North
Individual Rooms
0° 45° 90° 135° 180° 225° 270° 315° High
Rm. Room Rot. Rot. Rot. Rot. Rot. Rot. Rot. Rot. Duct
No. Name CFM CFM CFM CFM CFM CFM CFM CFM Size
System 1:
Zone 1:
1 Basement 45 61 55 38 56 *67 49 25 1-5
2 Mudroom 58 45 30 45 *59 58 43 54 1-4
3 Porch 145 204 235 241 197 *264 255 205 1-9
4 Foyer 114 145 144 124 89 128 *146 138 1-7
5 Great Room 203 283 317 306 238 335 *344 285 2-8
6 Kitchen 114 154 181 163 129 178 *196 155 1-8
7 Bedroom 1 61 77 82 68 50 74 *89 77 1-6
8 Bath 1 &2 19 26 28 22 15 24 *30 26 1-4
9 Bedroom 2 54 70 75 60 43 66 *82 70 1-5
10 Family Room 47 51 51 47 43 53 *57 53 1-4
11 Master Bath 31 38 41 34 26 37 *44 39 1-4
12 Master Closet 22 29 35 33 27 36 *38 30 1-4
13 Master Bedroom 90 150 197 180 131 197 *214 151 1-9
14 Office 93 117 126 134 117 *146 137 118 1-7
15 Laundry 38 39 38 43 44 *51 46 44 1-4
16 Stairs 153 203 235 209 164 229 *255 205 1-9
* Indicates highest CFM of all rotations.
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C lk 1816 Elie Court
Maplewood,MN 55109 0 Page 41
Building Rotation Report (cont'd)
Whole Building
Rotation Front door Supply Sensible Latent Net
Degrees Faces CFM Gain Gain Tons
0° North 1,286 27,445 *4,221 2.64
45° Northeast 1,691 36,099 4,221 3.36
90° East 1,871 39,929 4,221 3.68
135° Southeast 1,748 37,309 4,221 3.46
180° South 1,426 30,438 4,221 2.89
225° Southwest 1,944 41,503 4,221 3.81
270° West *2,025 *43,229 4,221 *3.95
315° Northwest 1,674 35,728 4,221 3.33
* Indicates highest value of all rotations.
Building Rotation Tonnage
3.8
3.6
to
o 3.4
t—
rn —
c
p 3.2
U
3.0
2.8
2.6 I t I I I t I t
North Northeast East Southeast South Southw est West Northw est
Direction Front door Faces
-----M--M- Building Net Tonnage
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C ` 1816 Elie Court
Maplewood,MN 55109 Page 42
Building Rotation Report (cont'd)
Building Rotation Hourly Net Gain
60,000
50,000
411-WM I I I I I s
3 "<
d
z 40,000
OI `
5
m
r
30,000
20,000 i I I I 4 I
8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm
Time of Day
Front door faces North
Front door faces Northeast
• Front door faces East
Front door faces Southeast
— Front door faces South
♦ Front door faces Southw est
Front door faces West
— — Front door faces Northw est
C:\Users\JHopk\AppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Perfection Heating and A/C 1816 Elie Court
Maplewood,MN 55109 Page 43
Building Rotation Duct Sizes
Direction Front door Faces
Room or N
NE E SE S SW W NW Max
Duct
Duct Name
Htg I Clg Htg Clg Htg i Clg Htg Clg Htg Clg Htg Clg Htg Clg Htg Clg Size
Flow Flow Flow Flow Flow j Flow Flow I Flow Flow Flow Flow Flow Flow Flow Flow Flow
System 1
Supply Runouts
Zone 1 ,
1-Basement 1185 118 61 118 51 118r 38 11 8111111 118 67 1181 49 1188 1--5
2-Mud room 35 F 58 35 45 35 34 35145 35 59 35 1 35 1 43 35_ 1--4
3-Porch 77 1 145 77 6,204 77 16 234 77 1 241 77 197 77 264 77 111655 77_ 2--7
4-Foyer 641 114 64 1145 641!144 641 124 64 89 6486,610 64 146 64_ 1--7
5-Great Room 1081 203 108.83 108 °314 1084 306 108 238 1088 108 344 108 3--6
6-Kitchen 581 1i 58 111154 58 181 581 163 58 129 58_ 58 196 58 8 2--6
7-Bedroom 1 411 di 41.;77 41 8 41 1 68 41 ilt 50 41_ 41 89 41 x"77 1--6
8-Bath 1 &2 12 1, ill 12.26 12 24 121 22 12 15 12 M. 12 30 12 W 26 1--4
9-Bedroom 2 251 d 25.'70 25 74 251°, 60 25 iiii. 43 25 11111 25 82 25 I 70 1--5
10-Family Room 37I A 37.'.51 37 54 371 47 37 43 37 51 37 57 37 53 1--4
11-Master Bath 28 L 31 28.;38 28 44 281 34 28 286 4 28 44 28 39 1--4
12-Master Closet 25 Ilb2 25.,29 25 34 251 33 25 a 25 F 34 25 38 25 30 1--4
13-Master Bedroom 59 Irk 59.150 59 191 591 180 59.131 59 11 59 214 59 151 2--6
14-Office 521 93 52 1.17 52 124 521 134 52 52 146 52_ 52 118 1--7
1 5-Laundry 26 P 38 26.`39 26 3 261 43 26_ 26 51 26_ 26 44 1--4
16Stairs 45 153 45.03 45 231 451 209 45_ 45_ 45 255 45 205 2--7
Other Ducts
Supply Main Trunk 811 1,24 811 1,691 811_ 8111 1,748 811_ 81 11=1 811 2,025 811x,.:1674 20x20
Bldg. High Dir.:West
Sensible Gain:43,229
Latent Gain:4,221
Summary
System 1
Heating Flow: 811
Cooling Flow: 1286
C:\Users\JHopkWppData\Local\Elite Software\Rhvac 8\1616 Elie ct.rhv Wednesday, February 28, 2018, 2:45 PM
Project Information
Project title: 1816 Elie Court
Designed by:
Project date: Wednesday, November 22, 2017
Project comment:
Client name:
Client address:
Client city:
Client phone:
Client fax:
Client comment:
Company name:
Company representative:
Company address:
Company city:
Company phone:
Company fax:
Company comment:
Item System 1
Air Handler Name
Cooling Description
Cooling Model Type Standard Air Conditioner
Cooling Model Number
Cooling Capacity 0 Btuh
Cooling Efficiency 0 SEER
AHRI Reference No.
Heating Description
Heating Model Type Natural Gas Furnace
Heating Model Number
Heating Capacity 0 Btuh
Heating Efficiency 0 AFUE
City Inspection Dept. Copy EAGAN��
City Forester Copy /�
Applicant/Builder Copy
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Madelyn Woods
Lot Number 5 Block Number 1
Address 1816 Ellie Court
Builder Sustainable Builders
Phone Number: 952-250-8869
Contact: Vince Birdslet
Tree Protection Requirements:
Tree Protection Fencing Installed on Site (Erosion tubes)
Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall to Be Installed
Other:
Replacement Trees:
Not Required
X As Follows: Five(5) Category B trees (>= 2.5" caliper deciduous
trees (or one Category B tree and two Category A trees) per
approved Tree Mitigation Plan to be installed following completion
of construction.
Attachments: ((��� �(''��
X Yes (Refer to ata ���ftsF ► STRY DIVISION
No REVIEW
Additional Notes: BY
DATE z - zZ -
td'
H:\ghove\2018file\treepres\Tree Preservation Plan Madelyn Woods Lot' Block 1
Surveyor's Certificate
SURVEY FOR :Won Jved
DESCRIBED AS :Loo5, Block Block 1, M WOODS, City Eagan, Dakota County. AO
Minnesota and reserving easements of r record. (WA ? ���
LOT SQ. OTA(pt.
T = 29,503
t 6. ,\ HSE SQ. FOOTAGE = 2,182
\\97.7 LOT SQ. FOOTAGE = 7.4%
51 1;i \ \ l If
l ►�� 956.7 /
\ o
)945_*
l a�;.*f Tree Protection Fencing(T.P.FJ-^'-'-`"
r o ^ Ora 4'Ploy Fence or Orange Silt Fence
110
Mr,'• �� og Shall be placed at the edge of each preserved
/ gyp\ 1:Y trees critical root zoon(CRZ is defined as a
r \\ �f�. X56.6 radius of one foot per each inchvof trunksdiameter)n
or at the edge of each preserved Vers crown
X�� !y f°••�• �!•g drip line,whichever is greater.
2421956.a .\ _ �.
I P Mitigation Plant List_
t\ � 1 1 \ ' ,�+ 'r3 ,�' �.6 a O Autumn Blaze Maple 2-1/2" B&B` ` I I -� X \ O Prairie Cascade 2-1/2" B&B
I I 95ea .
� 961.9
l I L / NOTE:
959.0 �N I� ( 962.4 Drop Grade at NW House Corner
NOTE: I I �\ \ ang
Install TPF tOH from House
Tree f 4 to be Mimed _ r \\61 /
Ir� by fled Arb ♦ � _ •6� � I �♦ 9 .5
cr 6, ,
�� :.13.
11ia�'_, n \x I X962.6
�7 f y 25.s4 N 96.• In 9620 /
N o i I \ ` . CVS ♦ / /380'
N ,I \\ii, �.� I ^-� la\\ 959.9'
4.4, I r. X
Z 4.41411;_;4116
�L - Proed 'r. 7 `• 959.4q ^ '.. -_-__ �_ _ 1,.46 2-Story 5.•.^ /0 r' Storm Sewer
ea m I -- •1•r9 1 . 9 Dcr 1.61j;I I
�1 / 1 O CO
gym W
5'' 1-/
Y \ Z40 Pr seed I RetI�Wag n.92� 1.67 .61.1 . A" - li ,
•
/I 9966 M�}�rd l Rock Ent C• San Sewer
�, / g )2 111, iia® -s Gara9e n ®9.5Ri I I?_IOC 1,•, 959.7
J +� Water Main
/ 1'•: i� ��- I " 20.92 l ( `�`\
(IVB�l 'r •
�� / 9T.z _s6,�\ L�l►�geirag / X \ _ '59.5
962.3 \- -- o T. �\
T.P.F\ \ r` _ _ • 960.2
\_ /-
.•�
ci
\ ' / :HUBS\ Drainage&Utility Easement
\986- 1.,:::..,--
b. • 7gO� _ 9/1:2 NOTE was never installed
I
Proposed Ashto be n
E° by Developer.Autu =1o(i)
Ji///J(,•
,7e.,-___,:- hr'50 Installed. /�
J / �Qlaoy'� CLl
/`
1 1e.•.
f' '
Th 411101:1013W1 / --7
, -",-„ blar(s.. *j °P4'40
PIO - _40 ,
, „..,:::,„.„,
/ ,
e7o.s `��,
97� .r •` r,,, / 1hp MgTM
(2) C4f 7 44 '
PROPOSED ELEVATIONS 4.,,,,,, *0,
I/ - r ENCHMARK,
c(1s• NH® Approx. 375 W. of Lenore
Top gFoundation = 963.6
Lane 8c Cliff Road & S. of Cliff
Garage Floor = 963.6 Elev- 959.4
Basement Floor = 955.3
Aprox. Sewer Service =
Verify
Proposed Elev. .--C---) MIN. SETBACK REQUIREMENTS
Front-30 House Side -10
Existing Elev. = Rear -50 Garage Side -10
Drainage Directions = SCALE: 1 inch- 30 feet
Denotes Offset Stake = • JOB NO:
I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTATION
SC517075
OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED BOOK:
A N D F 0 R BY ME OR UNDER MY DIRECT SUPERVISION AND SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPTAS SHOWN.S NOT TO PACE:
From Site to Finish • • - CAD FILE:
r
DATE /23/16 ERIC B. UNDGREN, AND SURVEYOR Madelyn Woods
1a6 S (51finMw.
en.SW MINNESOTA LICENSE NUMBER 481
76
YlaaeeDdle.MN ed4a�
Rene:(612)2a2-9a7a
LOT SURVEY CHECKLIST FOR RESIDENTIAL 111
C�
BUILDING PERMIT APPLIC
ATION
PROPERTY LEGAL: $ 4L,, I, a..,(]]?/ ' /
DATE OF SdRVEY: idfs
f/sem/ick
LATEST REVISION:
asm
as
/g/ H 04---
aa
0z a DOCUMENT STANDARDS
•' 0 ❑ • Registered Land Surveyor signature and company
.P'r 0 0 • Building Permit Applicant
X1 0 ❑ • Legal description
0 0 • Address
❑ ❑ • North arrow and scale
fa' ❑ ❑ • House type(rambler,walkout,split w/o,split entry,lookout,etc.)
0 ❑ • Directional drainage arrows with slope/gradient%
)i' 0 ❑ • Proposed/existing sewer and water services&invert elevation
' CI • Street name
,0' 0 0 • Driveway(grade&width-in R/W and back of curb,22'max.)
SP1 0 ❑ • Lot Square Footage
�0 ❑ ❑ • Lot Coverage
ELEVATIONS
Existing
• 0 0 • Property corners
re ❑ ❑ • Top of curb at the driveway and property line extensions
,f1 0 ❑ • Elevations of any existing adjacent homes
,8' ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches
12' ❑ ❑ • Waterways(pond,stream,etc.)
Proposed
,P 0 0 • Garage floor
,' 0 0 • Basement floor
.Fr ❑ ❑ • Lowest exposed elevation(walkout/window)
.,R' ❑ ❑ • Property corners
0Y ❑ ❑ • Front and rear of home at the foundation
N • PRV Required
PONDING AREA(if applicable)
❑ I 0 • Easement line
❑ ,el ❑ • NWL
❑ ,fi' ❑ • HWL
❑ ❑ • Pond#designation
❑ t ❑ • Emergency Overflow Elevation
❑ , • Pond/Wetland buffer delineation
Y • Shoreland Zoning Overlay District
Y • Conservation Easements
DIMENSIONS
❑ ❑ • Lot lines/Bearings&dimensions
❑ ,e( ❑ • Right-of-way and street width(to back of curb)
0 ❑ • Proposed home dimensions including any proposed decks,overhangs greater than 2',porches,etc.
(i.e.all structures requiring permanent footings)
,$' 0 ❑ • Show all easements of record nd a if, utilities within those easements
.' ❑ ❑ • Setbacks of proposed structure -•. sid erd •etback of adjacent existing structures
,e ❑ ❑ • Retaining wall requirements:
Reviewed AtIIa Date /l�f 6.
G:/1 Engineering/FORMS/Cert.of Survey Checklist Rev.11-16-16
Surveyor ' s Certificate / c1
/ / c (1 ,'e CI
SURVEY FOR . Irfan Javed
DESCRIBED AS : Lot 5, Block 1, MADELYN WOODS, City of Eagan, Dakota County, Rolfe rnr' _ ti i 4 Minnesota and reserving easements of record.
• l f � It i i L
.
1961.4 0Iv _i- ,• LOT SQ. FOOTAGE = 29, 503
_;' ° i\ HSE SQ. FOOTAGE = 2, 182
I \ 9 7.7 LOT SQ. FOOTAGE = 7. 4%
lik.1 `III
��1 3:1 Maximum Slopes
II*,A 956.7 Or Retaining VN81!Will
Ati-Iiik ),,,,,- � x--9,. , �,�„ ,t,
Be Required J
11.
•
90 9
X
oiu ... ;. 1 1 x 'y . , •56.6 0
A) t: `\ ;956.8 �\ Fo 2/L o .8
1 03s'' ��-' I1LTAVtER,,, ,
i ,
.,
AV C/Sf40 ��9'�'' PCONTROL
x
�� ' i 958.1 0 TI g _ .
I
I I " 9 961.9
I I `N \ 95 . (/ 962.4
B :HUB
I l \ X I 9•2.00
pal • ••9----.
13_ I \` X I X962.6 / /
N N o \\ \\ O � �1�'n n
00 ' \ c� 25. 4 96 .s I /
_® fV 5' ' \ -.� � i(c)
'La? ` 96.2_x
62 C 962.0 --
o \ •.2.4 - - ''- = Ini. \ �g6o-
� � `� I 4.46 `�
w \ x 4.42 I 959.91
ax Ro \_._.-.'ilk41 Obi N \ x
O Z rt ► `t 4i-3-...b \,s961.5 96/.1
3 O 'i
00 -9fi6 -___ _ q4`'♦� 11.46 Proposed^ >
1 2-Story 5 9•^ 7 , `9�0 959.4
O o 0 968.8 t: \ Pati. Deck o 8•Pcw 3 0
ger_'6.--2 ---_- x Mtn 96L ° 1.67�"��' t / 8 Storm Sewer
• RR
1
8.9 �� O Pro osed �in I x•92 ii0( 1
Ret Wall �j� k w 1.67 t 61.1 -i:gb-- ,----
T=956.01I�e1 / "� 9• • i
B=9i62.D, ; N ►� i:.:' /0CO . T
�� to ...61,/,
Rock Con.
I ) rail .r Garage l�9 5%i� II � Ent. San Sewer
7, / 11 ) (Plantings 0, I i J Lt'timkI 959.7
/ / �� Aw Water Main
/J4��j�� / 20.92
/ X 6 .2961 n
/ .r 962.: �- -- R TN
✓�{ / / X �� 9 '64 •59.5
\
S' --e e\ 962.3 0.� i
nc O � 960.2
ci \ \ -9f74- �� y 962` 960.2
i
/ /o T6
T \ 6---/ -' , �.,,:78 Drainage & Utility Easement
/ l -
..1 / 971:2 "`r.
\ /
J IV\. O O O
�97$� i� n ' �j
/ i'V GJ
/ �g�
r g7 j -�= \ 1 118.9. 22.58
( '1.5• `
/is 411016 / \,
/
o /
970.5 /
970.9 �� VVED
� ,_'�� / FN�Stip9
`J 9
� Date Z. /�j
c, r_ ,_,:
BAGAN iFr G DBPt
PROPOSED ELEVATIONS J ��
BENCHMARK,
Top of Foundation = 964.0
Garage Floor = 963.6 TNH® Ap�rox. 375' W. of Lenore
Basement Floor = 955.3 Lane & Cliff Road & S. of Cliff
Aprox. Sewer Service =
Verify Elev= 959.4
Proposed Elev. _ MIN. SETBACK REQUIREMENTS
Existing Elev. =
Drainage Directions = - Front -30 House Side -10
Denotes Offset Stake - . SCALE: 1 inch = 30 feet Rear -50 Garage Side -10
I HEREBY CERTIFY THAT THIS IS A TRUE AND CORRECT REPRESENTATION JOB NO:
OF THE BOUNDARIES OF THE ABOVE DESCRIBED PROPERTY AS SURVEYED
L A N D F R M SCSI
BY ME OR UNDER MY DIRECT SUPERVISION AND DOES NOT PURPORT TO
From Site to Finish
• • SHOW IMPROVEMENTS OR ENCROACHMENTS, EXCEPT AS SHOWN. BOOK: PAGE:
• •
-/
105 S. Fifth Ave. DATE 1 /3/1 8 CAD FILE:
Suite 513 ERIC B. LINDGREN, LAND SURVEYOR
Minneapolis, MN 55401 Madelyn Woods
Phone: (612) 252-9070 MINNESOTA LICENSE NUMBER 48176
Peggy Fleck
From: Vince Birdsley <vince@sustainable9.com>
Sent: Monday, May 14, 2018 12:37 PM
To: Peggy Fleck
Cc: Janelle Hanson
Subject: Re: New Mechanical Contractor for 1816 Ellie Ct
Hi Peggy,
We've changed HVAC subcontractors on 1816 Ellie Ct since we originally submitted our permit application.
Sustainable Heating& Cooling
21646"Thames St NE
Wyoming,Minnesota 55092
(651)462-1300
On Mon, May 14, 2018 at 10:24 AM, Chad Hanson<chadhanson@sustainable9.com> wrote:
See below from the city of Eagan... If you are using your guy, you should probably send his info to the city it
sounds like.
Forwarded message
From: Peggy Fleck<pfleck(a,cityofeagan.com>
Date: Mon, May 14, 2018 at 9:44 AM
Subject: New Mechanical Contractor for 1816 Ellie Ct
To: "billing@sustainable9.com" <billing@sustainable9.com>
Hello Janelle,
Please send me the contact information of the new mechanical contractor for 1816 Ellie Ct.
Thank you,
Peggy
>_
OF
m O
7s HS9
3830 Pilot Knob Road I Eagan MN 55122
Phone: (651)675-5675 I Fax: (651)675-5694
buildi nginspections(a�cityofeagan.com
Address: 1816 Ellie Ct Permit#: 148123
The following items were/were not completed at the Final Inspection on: /°— 2 T
-4
Complete Incomplete Comments
Final grade - 6"from siding
Permanent steps — Garage
Permanent steps— Main Entry IG
Permanent Driveway
Permanent Gas
Retaining Wall or 3:1 Max Slope
Sod / Seeded Lawn
Trail / Curb Damage -- --
Porch
Lower Level Finish "Mt Tz-e� 41.�°l/S Sfree a r)
tu% 5. e . I/5 S tee] cxj(Qi)
Deck
Fireplace �C
• Verify with your builder that roof test caps from the plumbing system have been removed.
• Turn off water supply to the outside lawn faucets before freeze potential exists.
• Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an
irrigation system.