Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
1314 Interlachen Dr
t_ e II 111 1 CEIV :D Use BLUE or BLACK InlC /' ��{� � For Office Use �, �(� 1 c , QCT IP f J � IT CiEa _L /S ge7-/0 7 Permit F I Permit Fee:/U16c�7, 3830 Pilot Knob Road (� 7� - /°C) CO I -5--( 3 Eagan MN 55122 /0 Q O Date Received: Phone:(651)675-5675 ;((!I c/s ' / - Staff: el Fax: (651)675-5694 /►I /O/ 6 7, / ' ` 2017 RESIDENTIAL �/ ' BUILDING PERMIT APPLICATION Date: (12! '12 Site Address: ttilt I�►" �0 Name: D.R. Horton, Inc Phone: q'G Jg '11 ,7 ,Resident/ 20860 Kenbridge Court Suite 100, Lakeville, MN 55044 - Ownei Address/City/Zip: 2 l Applicant is: Owner X Contractor �7�� New Residential, Single Family �T /1011.1 - Description of wor X Type of.V ork o D Construction Cost: 511/16° . Multi-Family Building:(Yes /No ) Company: D.R. Horton, Inc contact: Brooke Hareid 1 Address: 20860 Kenbridge Court city. Lakeville Contractor _" State: MN Zip: 55044 Phone: 952-985-7806 Email: bmhareid@drhorton.com License#: BC605657 Lead Certificate#: If the project is exempt from lead certification, please explain why: New Construction COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? Yes X No If yes,date and address of master plan: Licensed Plumber: Sabre Plumbing & Heating Phone: 763-473-2267 Mechanical Contractor: Sabre Plumbing & Heating Phone: 763-473-2267 Sewer&Water Contractor: Starr Plumbing 952-884-4149 Phone: Fire Suppression Contractor: /Pr Phone: NOTE:Pans and supporting documents that you submit are considered to be public information ,Portions of the information may;.be classified gas non-putblic if you specific reasons that would permit- ie City to ; conclude that they are trade:secrets - , c.:." tit ,A-4,0' CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit;that the work will be in accordance with the approved plan in the case of work which requires a review and approval of plans. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit is .cil,___ suance. _ L ac�1 X ' X4 *'1 Applicant's Printed Name � Applicant's Signature JV`. Page 1 of 3 a DO NOT WRITE BELOW THIS LINE(f f c�5 � E 7 SUB TYPES I I l --/ii )I cit kdl I—i, - . Foundation Fireplace Porch(3-Season) Exterior Alteration(Single Family) Single Family _ Garage Porch(4-Season) Exterior Alteration(Multi) Multi Deck Porch(Screen/Gazebo/Pergola) Miscellaneous 01 of Plex _ Lower Level _ Pool Accessory Building ORK TYPES New Interior Improvement Siding Demolish Building* Addition Move Building _ Reroof Demolish Interior Alteration Fire Repair Windows Demolish Foundation Replace Repair Egress Window Water Damage Retaining Wall *Demolition of entire building—give PCA handout to applicant DESCRIPTION Valuation7c,,LccupanCyLA)21 - MCES System Plan Review Code Edition '. *, _.'?r SAC Units (25% 100% )) Zoning / / . City Water Census Code Stories _ Booster Pump #of Units Square Feet } PRV #of Buildings Length iff/ Fire Suppression Required Type of Construction —V-6— `- Width ; REQUIRED INSPECTIONS Footings (New Building) Meter Size: Footings (Deck) Final I C.O. Required Footings (Addition) Final I No C.O. Required tr, Foundation , Foundation Before Backfill HVAC Gas Service Test Gas Line Air Test Roof: Ice&Water Final Pool: Footings Air/Gas Tests Final x, Framing 30 Minutes y 1 Hour Drain Tile " Fireplace:I Rough In ,/Air Test )(Final Siding: Stucco Lath Stone Lat Brick_EFIS 1Insulation 4ll`� Windows) Retaining Wall:_Footings Backfill Final Sheetrock - Radon Control Fire Walls Fire Suppression: Rough In_Final rBraced Walls 7, Erosion Control Shower Pan Other: Reviewed By: , Building Inspector RESIDENTIAL FEES /, Base Fee 1 ( `. t , i ',a ) x `) Surcharge / / / 1 ,, l0 Plan Review Is, )tt'�t MCES SAC C' )6e9b/1/4_,O .90 qiC Cis; i ( ? ..;ov, S-` /tea ell ' / - sc; 9.1 W V cy. City SAC Utility Connection Charge .-1 ,e.," ` �" t t S&W Permit&Surcharge (1I1il1 i, I Treatment Plant ` �f Copies t f�(1 0r " j , ate._ 11i TOTAL �`' ,. lxi �i Page 2of3 1 ,,, ,,„ go? , 7 New Construction Energy Code Compliance Certificate ' I N° Date Certificate Posted ^' ;4.-j _r Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel. 9/12/18 Mailing Address of the Dwelling or Dwelling Unit 1314 Interlachen Dr Name of Residential Contractor - MN License Number DRHorton BC605657 Community Plan ID Eagan 7031 THERMAL ENVELOPE RADON SYSTEM ,,-, Type:Check All That Apply x Passive(No Fan) 0 a E~ u Active(With fan and monometer or v c, other system monitoring device) 3 y o o a U Q° - -o v 2 cd DA a Location(or future Location)of Fan: a1 F 5) C .o >> Insulation Location a ° �' " ° a w . o In Attic o z � � U O � w F E . b H z w u, L, ° Ino C4 Other Please Describe Here Below Entire Slab X Foundation Wall(Sides) R-15 X R-10 Exterior,R-5 Interior Foundation Wall(Front and Back) R-10 X Exterior Rim Joist(Foundation) R-20X Interior Rim Joist(lot Floor+) R-20 XInterior Wall R-21 X Ceiling,flat R-49 X Ceiling,vaulted R-49 X Bay Windows or cantilevered areas R-30 X Bonus room over garage R-32 X X Describe other insulated areas Building Envelope air Tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: 0.31 Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 0.31 R-8 R-value MECHANICAL SYSTEMS [ Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code Fuel Type NAT GAS NAT GAS R-410A Passive Manufacturer Bryant Rheem Bryant Powered Interlocked with exhaust device. Model 9125C48100521 PROG5042NRH67PV BA13NAO42 •Describe: Input in 100000 Capacity in 50 Output in 3.5 Other,describe : Rating or Size BTUS: Gallons: Tons: AFUE or 92% 84 SEER or 13 Location of duct or system: Efficiency HSPF% EER HEAT LOSS HEAT GAIN COOLING LOAD I RESIDENTIAL LOAD CALL 74,518 29,369 36,806 II Cfin's K "rouna duct U Mechanical Ventilation System I "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace Not required per mech.code Select Type X Passive Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: X Energy Recover Ventilator(ERV)Capacity in cfms: Low: 40%=124 High: 70%=217 Location of duct or system: Balanced Ventilation Capcity in CFMS: furnace room [ Locations of Fans,describe: Cfin's Capacity continuous ventilation rate in cfins: 100 5 "round duct OR Total ventilation(intermittent+continuous)rate in cfins: 200 "metal duct 1314 Interlachen Dr Eagan HVAC Load Calculations for DR Horton Lakeville, MN Prepared By: Michael Hoium Sabre Plumbing&Heating 15535 Medina Road Plymouth, MN 55447 763-473-2267 Wednesday, September 12,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhv o Residential 43,Light Commercial„HVAC Loads EIiter oftware Development, Sabre Piumbing&Heating: ''t31�t Interlachen Dr Eagan Plymouth,MN 55447: x �Y , ...., ,, ., �_... Page Project Report General Project:liifo nation Project Title: 1314 Interlachen Dr Eagan Designed By: Michael Hoium Project Date: Wednesday, September 12, 2018 Client Name: DR Horton Client City: Lakeville, MN Company Name: Sabre Plumbing & Heating Company Representative: Michael Hoium Company Address: 15535 Medina Road Company City: Plymouth, MN 55447 Company Phone: 763-473-2267 Company Fax: 763-473-8565 Design Qat Reference City: Minneapolis, Minnesota Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 n/a 30% 72 29.40 Summer: 88 73 50% 50% 75 35 ChecIajores Total Building Supply CFM: 1,313 CFM Per Square ft.: 0.261 Square ft. of Room Area: 5,033 Square ft. Per Ton: 1,641 Volume (ft3): 43,199 l3it€irg Loads ... a. �:z. 4 .. Total Heating Required Including Ventilation Air: 74,518 Btuh 74.518 MBH Total Sensible Gain: 29,369 Btuh 80 Total Latent Gain: 7,437 Btuh 20 Vo Total Cooling Required Including Ventilation Air: 36,806 Btuh 3.07 Tons(Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. Wednesday, September 12, 2018, 12:18 PM • Rhvac- gigh lmer l IN L d it S 0nrbi & �tagAy 1 4 pt c e 4 a *mouth,MN -S7", � .,,,... .., P €1e 3 Load Preview Report Sys Net ft.2 Sen Lat Net Sen Htgs Clg Sys Act Duct Scope Ton /Ton Area Gain Gain. Gain Loss Size CFM CFM CFM Building 3.07 1,641 5,033 29,369 7,437 36,806 74,518 877 1,313 1,313 System 1 3.07 1,641 5,033 29,369 7,437 36,806 74,518. 877 1,313 1,313 12x18 Ventilation 1,110 4,641 5,751 7,428 Supply Duct Latent 484 484 Return Duct 236 211 447 1,573 Humidification 7,620. Zone 1 5,033 28,023 2,101 30,124 57,897 877 1,313 1,313 12x18 1-Basement 1,470 3,872 0 3,872 16,536 250 181 181 2--6 2-Main Floor 1,465 13,173 2,101 15,274 17,222 261 617 617 6--6 3-Second Floor 2,098 10,979 0 10,979 24,139. 366 514 514 5--6 • Wednesday, September 12, 2018, 12:18 PM Rhvac-Residential&Light Commercial HVAC Loads Mite Software Development,Inc Sabre Plumbing&Heating 1314 Interlaehen Dr-Eaagan Piyrnouth,MN 55447 Page 4 Total Building Summary Loads Cpm onont Area Sen Lat Sen k Loss Gain{. Glrf.:_r ©r~sdr� `��;i' � = � Quin . ZIGajo„ DRH LowEE 3228: Glazing-DRH Windows, u-value 0.32, 45 1,254 0 762 762 SHGC 0.28 DRH LowEE 2929: Glazing-DRH Windows, u-value 0.29, 40 1,009 0 679 679 SHGC 0.29 DRH LowEE 3131: Glazing-DRH Windows, u-value 0.31, 158 4,264 0 2,535 2,535 SHGC 0.31 DRH LowEE 3132: Glazing-DRH Windows/Glass Doors, 94 2,536 0 2,116 2,116 u-value 0.31, SHGC 0.32 DRH LowEE 3123: Glazing-DRH Door w/Sidelite, u- 13.3 360 0 112 112 value 0.31, SHGC 0.23 DRH LowEE 3028: Glazing-DRH Windows, u-value 0.3, 210.8 5,507 0 2,723 2,723 SHGC 0.28 DRH Door 31 UF: Door-DRH Exterior Door- .31 U Factor, 37.8 1,018 0 281 281 .23 SHGC Eagan - R15 9ft: Wall-Basement, Custom, Eagan -8" 540 2,772 0 274 274 poured concrete wall, R-15 board insulation to footing, no interior finish, 9'floor depth Eagan - R15 4ft: Wall-Basement, Custom, Eagan -8" 96 492 0 48 48 poured concrete wall, R-15 board insulation to footing, no interior finish, 4'floor depth 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 3217.1 18,192 0 2,782 2,782 cavity, no board insulation, siding finish, wood studs Eagan - R10 9ft: Wall-Basement, Custom, Eagan -8" 396 2,033 0 201 201 poured concrete wall, R-10 board insulation to footing, no interior finish, 9'floor depth RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 513.5 2,234 0 628 628 Closed Cell Spray Foam R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 2098 4,198 0 2,316 2,316 Attic Floor(also use for Knee Walls and Partition Ceilings), Custom, R-49 Blown Insulation, No Radiant Barrier, Vented Attic, Asphalt Shingles 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1470 3,453 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 20'wide P-32 R-32: Floor-Over open crawl space or garage, 651 1,699 0 156 156 Custom, R-30 Blanket insulation, 3/4" Foamboard R- 2, any cover Subtotals for structure: 51,021 0 15,613 15,613 People: 6 1,200 1,380 2,580 Equipment: 901 4,116 5,017 Lighting: 1250 4,263 4,263 Ductwork: 8,449 696 1,732 2,428 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 200, Summer CFM: 200 7,428 4,641 1,110 5,751 Humidification (Winter)20.78 gal/day : 7,620 0 0 0 AED Excursion: 0 0 1,155 1,155 Total Building Load Totals: 74,518 7,437 29,369 36,806 Check Figures Total Building Supply CFM: 1,313 CFM Per Square ft.: 0.261 Square ft. of Room Area: 5,033 Square ft. Per Ton: 1,641 Volume (ft3): 43,199 Building Loads Total Heating Required Including Ventilation Air: 74,518 Btuh 74.518 MBH Total Sensible Gain: 29,369 Btuh 80 Total Latent Gain: 7,437 Btuh 20 Wednesday, September 12, 2018, 12:18 PM 7;.441.4(a,c,l,gesiontial Elite Soft eveluprr nt,Inc Sabr `Plumbl )0,:gii 41314lnteriachen Cir Ea an ` m uth,MI4.6'6447 . .,., . .,.,,' , ,. :;;SlibliY Total Building Summary Loads (cont'd) Buiildinq Lo dtM„u,,,,;eti .,.y.. ,,, .. Total Cooling Required Including Ventilation Air: 36,806 Btuh 3.07 Tons(Based On Sensible+Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and Iatentloads according to the manufacturer's performance data at your design conditions. Wednesday, September 12, 2018, 12:18 PM • Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Sabre Plumbing&Heating 1314 Interlachen Dr Eagan; f :k Ptl+rr�autli;-�/Its '55447 ,% , Page 6' Detailed Room Loads - Room I - Basement (Average Load Procedure) erg Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 29.4 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 1,470.0 sq.ft. Supply Air: 181 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 0.8 AC/hr Volume: 13,230 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 57 CFM Runout Air: 91 CFM Percent of Supply.: 31 % Runout Duct Size: 6 in. Actual Summer Vent.: 28 CFM Runout Air Velocity: 462 ft./min. Percent of Supply: 15 % Runout Air Velocity: 462 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.133 in.wg./100 ft. Actual Summer Infil.: 0 CFM !tent 1 u � t. ' I !, Clg-'-,,J,' Lat i D scription.. , . Quantity ,N alue.. t ..>�,KM :° ;Gairt Gain-'; ,.. Loss W-Wall-Eagan - R15 9ft 30 X 9 270 0.042 5.1 1,386 0.5 0 137 W-Wall-Eagan - R15 4ft 12 X 4 48 0.041 5.1 246 0.5 0 24 W-Wall-12F-Osw 12 X 5 60 0.065 5.7 339 0.9 0 52 S -Wall-12F-0sw 44 X 9 311 0.065 5.7 1,759 0.9 0 269 E -Wall-12F-Osw 12 X 5 60 0.065 5.7 339 0.9 0 52 E -Wall-Eagan -R15 4ft 12 X 4 48 0.041 5.1 246 0.5 0 24 E -Wall-Eagan -R15 9ft 30 X 9 270 0.042 5.1 1,386 0.5 0 137 N -Wall-Eagan - R10 9ft 44 X 9 396 0.050 5.1 2,033 0.5 0 201 W-Wall-RJ 20 Spray Foam 42 X 63 0.050 4.4 274 1.2 0 77 1.5 S -Wall-RJ 20 Spray Foam 44 X 1.5 66 0.050 4.4 287 1.2 0 81 E -Wall-RJ 20 Spray Foam 42 X 1.5 63 0.050 4.4 274 1.2 0 77 N -Wall-RJ 20 Spray Foam 44 X 1.5 66 0.050 4.4 287 1.2 0 81 S -Gls-DRH LowEE 3228 shgc-0.28 45 0.320 27.8 1,254 16.9 0 762 0%S (3) S -Gls-DRH LowEE 2929 shgc-0.29 40 0.290 25.2 1,009 17.0 0 679 0%S Floor-21A-20 50 X 29.4 1470 0.027 2.3 3,453 0.0 0 0 Subtotals for Structure: 14,572 0 2,653 Infil.: Win.: 0.0, Sum.: 0.0 1,806 0.000 0 0.000 0 0 Ductwork: 1,964 207 AED Excursion: 160 Lighting: 250 853 Room Totals: 16,536 0 3,872 Wednesday, September 12, 2018, 12:18 PM Rhvac -Residential&Light Commercial HVAC Loads 5,,,,,5,,,,„,,r- 13141trtt tla hen Dr-Ea an Sabre Ptumbiru�&Heating � � � � � �, Plymouth,MN 55447" Page 7' Detailed Room Loads - Room 2 - Main Floor (Average Load Procedure) General .... �. Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 29.3 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 1,465.0 sq.ft. Supply Air: 617 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.8 AC/hr Volume: 13,185 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 6 Actual Winter Vent.: 59 CFM Runout Air: 103 CFM Percent of Supply.: 10 % Runout Duct Size: 6 in. Actual Summer Vent.: 94 CFM Runout Air Velocity: 524 ft./min. Percent of Supply: 15 % Runout Air Velocity: 524 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.171 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area U � L ` SeriDescr ter rQ amity w e-vbk:2-4'-kticaos, HTM -oss C t t: W-Wall-12F-Osw 42 X 9 358 0.065 5.7 2,024 0.9 0 309 S -Wall-12F-Osw 44 X 9 284 0.065 5.7 1,606 0.9 0 246 E -Wall-12F-Osw 42 X 9 360.2 0.065 5.7 2,037 0.9 0 311 N -Wall-12F-Osw 44 X 9 296.7 0.065 5.7 1,678 0.9 0 256 W-Wall-RJ 20 Spray Foam 45.5 X 53.1 0.050 4.4 231 1.2 0 65 1.2 S -Wall-RJ 20 Spray Foam 64 X 1.2 74.7 0.050 4.4 325 1.2 0 91 E -Wall-RJ 20 Spray Foam 45.5 X 53.1 0.050 4.4 231 1.2 0 65 1.2 N -Wall-RJ 20 Spray Foam 64 X 1.2 74.7 0.050 4.4 325 1.2 0 91 N -Door-DRH Door 31 OF 3 X 6.7 20 0.310 27.0 539 7.4 0 149 E -Door-DRH Door 31 OF 2.7 X 6.7 17.8 0.310 27.0 479 7.4 0 132 W-Gls-DRH LowEE 3131 shgc- 8 0.310 27.0 216 33.0 0 264 0.31 0%S W-Gls-DRH LowEE 3131 shgc- 12 0.310 27.0 324 33.0 0 396 0.31 0%S S -Gls-DRH LowEE 3131 shgc-0.31 12 0.310 27.0 324 18.2 0 218 0%S S -Gls-DRH LowEE 3131 shgc-0.31 30 0.310 27.0 810 18.1 0 544 0%S (2) S -Gls-DRH LowEE 3132 shgc-0.32 30 0.310 27.0 809 18.6 0 558 0%S S -Gls-DRH LowEE 3132 shgc-0.32 40 0.310 27.0 1,079 18.6 0 744 0%S N -Gls-DRH LowEE 3131 shgc-0.31 66 0.310 27.0 1,780 9.9 0 652 100%S (4) N -Gls-DRH LowEE 3123 shgc-0.23 13.3 0.310 27.0 360 8.4 0 112 100%S(2) Subtotals for Structure: 15,177 0 5,203 Infil.: Win.: 0.0, Sum.: 0.0 1,804 0.000 0 0.000 0 0 Ductwork: 2,045 703 AED Excursion: 543 People: 200 lat/per, 230 sen/per: 6 1,200 1,380 Equipment: 901 3,638 Lighting: 500 1,705 Room Totals: 17,222 2,101 13,173 Wednesday, September 12, 2018, 12:18 PM Rhvac-Residential&,Light Commercial l-WAC Loads ,, Elite Software Development,Inc. Sabre Plumbing&Heating , 1314 fnteriachen Dr Eagan Plymouth,Mrs 55447', r„ page 8` Detailed Room Loads - Room 3 - Second Floor (Average Load Procedure) Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 42.0 ft. System Number: 1 Room Width: 50.0 ft. Zone Number: 1 Area: 2,098.0 sq.ft. Supply Air: 514 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.8 AC/hr Volume: 16,784 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 83 CFM Runout Air: 103 CFM Percent of Supply.: 16 Runout Duct Size: 6 in. Actual Summer Vent.: 78 CFM Runout Air Velocity: 524 ft./min. Percent of Supply: 15 % Runout Air Velocity: 524 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.171 in.wg./100 ft. Actual Summer Infil.: 0 CFM tem ,,,,:',14--'-'1::12- ,� Area U Htg Sen Clg'-'' '''''':Mf--1)44;"'/N-'''''''''s Sen::, De-r.+i tioi ., � _ ... gx.. ... aiitit '; Value ,HTMl ss : HTM . .. , ,�,aioi .,,,.,>v Gain W-Wall-12F-0sw 45.5 X 8 340 0.065 5.7 1,923 0.9 0 294 S -Wall-12F-Osw 64 X 8 387 0.065 5.7 2,188 0.9 0 335 E -Wall-12F-Osw 45.5 X 8 364 0.065 5.7 2,058 0.9 0 315 N -Wall-12F-Osw 64 X 8 396.2 0.065 5.7 2,241 0.9 0 343 W-Gls-DRH LowEE 3132 shgc- 24 0.310 27.0 648 33.9 0 814 0.32 0%S (2) S -Gls-DRH LowEE 3028 shgc-0.28 105 0.300 26.1 2,744 16.7 0 1,750 0%S (7) S -Gls-DRH LowEE 3131 shgc-0.31 20 0.310 27.0 540 18.1 0 362 0%S (2) N -Gls-DRH LowEE 3028 shgc-0.28 90 0.300 26.1 2,352 9.2 0 828 100%S (6) N -Gls-DRH LowEE 3131 shgc-0.31 10 0.310 27.0 270 9.9 0 99 100%S N -Gls-DRH LowEE 3028 shgc-0.28 15.8 0.300 26.1 411 9.2 0 145 100%S UP-Ceil-R49 16B-49 42 X 50 2098 0.023 2.0 4,198 1.1 0 2,316 Floor-P-32 R-32 31 X 21 651 0.030 2.6 1,699 0.2 0 156 Subtotals for Structure: 21,272 0 7,757 Infil.: Win.: 0.0, Sum.: 0.0 1,752 0.000 0 0.000 0 0 Ductwork: 2,867 586 AED Excursion: 453 Equipment: 0 478 Lighting: 500 1,705 Room Totals: 24,139 0 10,979 Wednesday, September 12, 2018, 12:18 PM Site address 1314 Interlachen Dr Eagan Date 9/12/2018 Contractor Completed Sabre Plumbing & Heating By Michael H Section A Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation 11-1) Square feet(Conditioned area including 5033 Total required ventilation 200 Basement—finished or unfinished) - Continuous ventilation 5 100 Number of bedrooms Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation 11-1. The table and equation are below Table R403.5.2 Total and Continuous Ventilation Rates(in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/ so ft.) continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake,or both,for defrost or other equipment cycling. Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided, on a continuous rate average for each one-hour period.The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. • Section B Ventilation Method (Choose either balanced or exhaust only) ✓ Balanced,HRV(Heat Recovery Ventilator)or ERV(Energy Recovery l� Exhaust only Ventilator)—cfm of unit in low must not exceed continuous I I Continuous fan rating in cfm ventilation retina by more than 100%. Low cfm: A 217 High cfm: Continuous fan rating in cfm(capacity must not exceed 1 •+ continuous ventilation rating by more than 100%) Directions-Choose the method of ventilation,balanced or exhaust only.Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts.Law cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Schedule Description Location Continuous Intermittent Directions-The ventilation fan schedule should describe what the fan is for,the location,cfm,and whether it is used for continuous or intermittent ventilation.The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than.100%greater than the continuous rate.(For instance,if the low cfm is 40 cfm,the continuous ventilation fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls (Describe operation and control of the continuous and intermittent ventilation) ERV has wall control-set to 40%=124cfm ERV has wall control-set to 70%=217cfm Directions-Describe the operation of the ventilation system.There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance.Related trades also need adequate detail for placement of controls and proper operation of the building ventilation.If exhaust fans are used for building ventilation,describe the operation and location of any controls,indicators and legends.if an ERV or HRV is to be installed,describe how it will be installed.If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures' installation instructions.If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation,such interconnection shall be made and described. SectionE Make-up air i = #a`n01te;(determined'km c l slatio s-1'04in Table:,O i) i -' Powered(determined fromc,il ulat is from Tan*501.1_11) II 1 mertoc ked with extmist devkt We-M ft:limed frofr,catutation tom Tarte 50-1,3,1) t1tfin a sc€i _ NR Lot abort of duct or system vetrtita€tots make-up air.Determined from I t -up ait opening table Ctm Size and t (round teetangtdat,flex or r1 t$i' (NR means not required Directions-In order to determine the makeup air,Table 501.4.1 must be filled out(see below).For most new installations,column A will be appropriate,however,if atmospherically vented appliances or solid fuel appliances are installed,use the appropriate column. Please note,if the makeup air quantity is negative,no additional makeup air will be required for ventilation,if the value is positive refer to Table 501.4.2 and size the opening.Transfer the cfm,size of opening and type(round,rectangular,flex or rigid)to the last line of section D. Table 501.4.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical- vent or direct vent ap-pliances assisted appliances and power gas or oil appliance or one solid ly vented gas or oil appliances or no combus-tion appliances vent or direct vent appliances fuel appliance or solid fuel appliances Column D Column A Column B Column C 1. 0.15 0.09 0.06 0.03 a)pressure factor (cfm/sf) b)conditioned floor area(sf)(including 5033 unfinished basements) Estimated House Infiltration(cfm):[la 755 x lb] 2.Exhaust Capacity a)continuous exhaust-only ventilation system ERV=0 (cfm);(not applicable to ba-lanced ventilation systems such as HRV) b)clothes dryer(cfm) 135 135 135 135 c)80%of largest exhaust rating(cfm); Kitchen hood typically 240 (not applicable if recirculating system or if powered makeup air is electrically interlocked d)80%of next largest exhaust rating Not (cfm);bath fan typically Applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked Total Exhaust Capacity(cfm); 375 [2a+2b+2c+2d] 3.Makeup Air Quantity(cfm) 375 a)total exhaust capacity(from above) b)estimated house infiltration(from 755 above) Makeup Air Quantity(cfm); [ —u6] /�^O (ifif — value is negative,no makeup air is needed) `{J`},{J 4.For makeup Air Opening Sizing,refer NOT REQ'D to Table 501.4.2 A.Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent appliances may be used.) B.Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may also be included.) C.Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. D.Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fule appliances. • Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units One or multiple power One or multiple fan- One atmospherically vented Multiple atmospherically Duct di- vent,direct vent ap- assisted appliances and gas or oil ap- vented gas or oil ap- ameter pliances,or no combus- power vent or direct vent pliance or one solid fuel pliances or solid fuel tion appliances appliances Column B appliance appliances Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 _144-195 100-135 62-83 8 Passive opening 318-419 196-258 136-179 84-110 9 w/motorized damper Passive opening 420-539 259-332 180-230 111-142 10 w/motorized damper Passive opening 540-679 333-419 231-290 143-179 11 w/motorized damper Powered makeup air >679 >419 >290 >179 NA Notes: A.An equivalent length of 100 feet of round smooth metal duct is assumed.Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. B.If flexible duct is used,increase the duct diameter by one inch.Flexible duct shall be stretched with minimal sags.Compressed duct shall not be accepted. C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D.Powered makeup air shall be electrically interlocked with the largest exhaust system. Combustion air Not required per mechanical code(No atmospheric or power vented appliances) ✓ Passive(see IFGC Appendix E,Worksheet E-1) ,Size and type 14°Rigid,5"Flex Other,describe: Explanation-If no atmospheric or power vented appliances are installed,check the appropriate box,not required.If a power vented or atmospherically vented appliance installed,use IFGC Appendix E,Worksheet E-1(see below).Please enter size and type.Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. • Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace,Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance information. Furnace/Boiler: 100000 Mgt Hood Dan Assisted ✓ Direct Vent Input: Btu/hr or Power Vent Water Heater: 40000 raft Hood Z Fan Assisted Direct Vent Input: Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 598 ft3 LxWxH 6.5 L ®WnH Step 3:Determine Air Changes per Hour(ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) 4a.Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft3 Volume(TRV) If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed. If CAS Volume(from Step 2)is less than TRV then go to STEP S. 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: 40000 Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3000 ft3 Required Volume Fan Assisted(RVFA) Total Btu/hr input of all Natural draft appliances Input: 0 Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: 0 ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= 3000 + 0 _ 3000 TRV ft3 Step 5:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio= 598 / 3000 = 0.20 Step 6:Calculate Reduction Factor(RF). RF=lminus Ratio RF=1- 0.20 = 0.80 Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000 Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr (EXCEPT DIRECT VENT) Combustion Air Opening Area(CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 CAOA= 40000 /3000 Btu/hr per int= 13.33 in2 Step 8:Calculate Minimum CAOA. Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 13.33 x 0.80 = 10.68 in2 Step 9:Calculate Combustion Air Opening Diameter(CAOD) • CAOD=1.13 m ultiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 3'69 in.diameter go up one inch in size if using flex duct 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method(cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 ' 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 _5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 ,9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 J 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1.The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2.This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. EAGAN City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Dakota Path 4th Add. Lot Number 5 Block Number 3 Address 1314 Interlachen Drive Builder D. R. Horton Phone Number: 612-508-1642 Contact: Kevin Tree Protection Requirements: Tree Protection Fencing Installed on Site(Erosion tubes) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: Not Required: X As Follows: Four(4) Category B trees (>= 2.5" deciduous trees). Mitigation trees to be installed following construction,three(3) Discovery Elm in front yard area and one(1) Swamp White Oak in east side yard area. All backyard trees have been installed by developer. .•.-•--w EAGAN FORESTRY DIVISION Attachments: REVIEWED 40 X Yes (Refer to aft c •_ en s for details ,I I No DATE to ✓ 4LC� Additional Notes: H:\ghove\2017fi1e\t epres\Ree Preservation Plan Uakot-F't 4'Add.Lot b EROca a 'Jo �I 0 �} I a r 4 m ' oz -- g' m v<�� Dr mz' -, naq z z 0 o�m C Nib r- --I8m`\ II 00J O Oma= I 1n ....J€.5 C 1.--ID _ (5) 1072.4, 0,m r 1075.2 g )(mo.7) o Won °x�O® PP o L. N00°19'02"W 134.27 ! -�> :-,_,\ o ou 1069.2 42 00 {+}/ 0.01 E 1, �1 N (1088.0) , _ 1074.4-.-r,i (10?5.1)cn i ' r -!1 -11303333333 I 5 NI IN \91"0. \ 3 J 7 J 7 J 9 9, > R0 0 ;0 0 0 0 I ; 01 ip(/) CP I0761: -iE. \ '\o \N� ° o.l1s_ o °o c n n•v, I111��i1- \�, \ p `p� \ ' (,� (��C�` f n m , 0.°' 0 3 m SCO t1�i K �.,p.O m `�` o° m I�'(' ND_ IIS C 3 O \ \ a m rt ielk ^L ?m I v A W 11076.2 ` EIL l''') f S� `. ,10 22 •N 'AlAlC D 1 e 0070,5 > '2.0� <-0 5.2% �, \\� v� : g12 ( o mo a am , \ y . �t 1 moi, zm �`E I -...,.2,;,..\24,0\ 1075.9 � silo L- 1 .,''12.50 12.500-sem 1 - - i0 \j \ �, °1 i--- (1069.6)0, `K(1078.3) 107fi.3-Y u1076.7 �,y4? o'y` 1071.0 42.00 _A(..1_078.3) 6\.. 5 .49 =1\ \ w g N00°19'02"W 162.75 \ `04'° j / � 1 r /% 0 \ m1m j % /A1'AI\I-r �te / 17: a C1WOvr1vf11 I I ^T � LV f J y N7 °m Q {A- 0. 4A. aQ cJ J 3 .,. `e2 -3 3 - Co Ci 0 Z 2 =d c) "T1 -1 W m J w P, m ° < 'm• c '`4,' ^ > ' c .4 r- o m A w ni�-• Z w x r- 'j .. a 3 < °mo- < m mww O o z o a 0 v, p rri S'• St 5. Am _,...n1 - .s c-) ooar Z7 _ a3 77 Llv v:$ Z522 a„mm m ° m w m m w oo »v 0 w 0 oavo 171 3 = 3'a.=v ° m-- 3gE,'' (I) ,1 o XI 2+ m,� :U A m < o r- y Zu7v2 ` 8 TO nFH 3a a -I F -1 .6> m m y V) .� (Tl w nP f71 xi ° w m m 2 ° ^.a `* m no w " .< <" -< 3! < mo•o.a. O o ° ° G oro.2,so Q. m" � ° o'0J a A D O 3. 0 3 3� N m y s f7 F' -D^i a r�•y n a O m``;.4.H o N IH �O�Kv f- C RI iu A in r- 2 3 3 3 � C E:-.s 'V O O N 0 0 0 4° 0. N 11 C M S 7 n ' 0.- V O N a 3 7,124 0 Eno 0���° m m-oc �°^m So ^am Nov m O .� N in W V 11AOm O N- o m n-, a 0 :..1.,.„,- .6 z �Q ad *V W a. NN�3 ,ii,, R O A.G O p 'F 3 N O w O S a' S S 3 6 .. , m E•9 i.,,� m an.km ma cm a o .tea o,n rt% II, V awv<�' a.m. nm 1 > pv °'' a;°: A 4 a '2-1 o -5, z0. e2 m m °< moi° ° _� m '" 2a'111 - a foo voamN [ o I ti mV O 2 3 13 3 a-° N;. T z g g C ME OF SURVEY (z_ill) Jamey R. Hill, InC. m . E 5�q �,> FORo a M o'' v iR BOR7VN, A(C. - JttAIDG OTA PLANNERS/ENGItEERS/SURVEYORS O ZO co y°, WLot 5, Block 3, DAKOTA PATH 4TH25�NEST COUNTY ROAD 42,SUITE 120, ADDITION, Dakota County, Minnesota. BU E: ,MN 55337 ' - RCM(952)890-6044 FAX(952)890-8244 All J• ...- ' • ,.,..,, , . i •r . 1 ( / •' 1 A ; i , -... -...., 'N'N'N'N.,,,,„.' ........ ........ y r---1 __........_...... IrDI /.: ' -,,,..„,•\,.......,',41.., ,,,, , •-•„ -. . / „„ ..... -.... . ..„-,..?,,,,--„,-,/ ' / ‘i ju---, ,. •. ---.. --- .'„...,-' -• ,4,....___ , ....,„„.. v-,... ......... „_ , i 0 0 -yam ' ., -., ••. , - r' 1 1 I '..... . -- -.''''''' / p..._-. .....,...,:-."___, \. -- -- .N.... , - •,,,..: .,, i , N _,/ ; I / t„,----—^,•'=-..--.."`"^-, \N. \ klfr..' ------',.:\ \ ,, • ' ),,/\ i .' --....1-7-'-' 1 . ,„, , *fru 1 r,„.., \ if Uff-- V ' 3R i / , , i ci,„ , , .„ , , s .._"-- ... , \ \ i , , N,..H-,..../'y 11 .z ‘ / ,.... 6 s., i+) __ . ..,, , , • , l' -,-, 4 - /_.- -___ 1 t / A---- I 1 s, \ -%'''' .,) ' 1 . ... ..... , . / I i, 1% I,. : .4,.. ; • -•.'.:-.., • ,, \v., ,, i ,J •••,- •-•,,,,,, ',I ..11/14 -,,":„;,,, 4 „ I : in , \ I .,-‘ 4' / \ / l 7,` , ,' i i . 01, 41,y, 1 / ,.../:t„.4., if :„..„ i 1 . • , ....„ I /Is , • 1 , i / .• , , . ... # i f / 1 .„ , i ! :‘,. ,.., •-• - / ',---, , \ — / \ ) • , , i , 1 — ,, , . • i Pre, • 11/fl i 1 ! !I-•, , . I ,, & IN -f i 1 1 •,,V . \ \ I .1/ ! • i^.6, : i I ( iiy -f-) . . . „. i • ' '. i i I I ;/\'tf.. ..../ -,.i. I_ r•„.'-‘.. ••. --, 1 s. • • , 4 , I.-• 2... . , --.... : • .. . •• 7\ i Y , i , \ ,•...,,. -,- Vf „ i ,/ . .,\‘,/;....,„; .. ,,, 7 , , , , • . , z i .-' ' 'r '''-- ,C:7!? ; •/, ! I \ a. , ,... : \ :,...( i / ( NN N . I •,,, gi , —' r ' ' '' r''.. A • .. .: 'It: - /1 /0- ",:- I '' 1 't" i\ ....4.' •• I. / 'N $ . i / 1 i ,•.„. . '-.0.- ° ; • ; , •\,. ..li if. % • , I ;- ri4 ' ./ ,7 ,/ 7 ,.H , ., • A v.\".,. • ) „ ;-- 1 4 4 / -1:. I 1 4 ; 'IL..^•^>- i 4 '4 44' ‘ '' 's I I ; ' PROPOSED I ; s. •; 1 V 11-'TIP'. ''.4.; 'f. /' I" a, / 1 ' . 4 WI < ; i :/ at eLAN spwr Pr] , ! ! , : . iv i I \ • , \ ...,,, " i ,•:, / : Tir:>--,:*--,—,..*, \ ,f i 41IN s••• '-'1"-•. -::1)"N) ' s‘: ''• too t , . C"--' :'''• .. - ....a, ,..4 / . I '\ 1----it • ,--;..•;;;•.,-;:••••—; •°, h,-•,4' ...,- ,„,,,...7, \.,,, , •,• , I ' '- ' ' ; ' \ -..;,..... ,/,- --IT ‘.•.,,,:,, , ; : f ; ,, \. $.'"a 'V - ,' f• • ELLE ,, , . . ,. ...... ,, , V, • . - - A ,"<—---".4..-.N..1..t..—„•„– -,•........,...,,z,_1.,,,,,...„,_r I.,,... /,,.,,,\„,.„/.,...,,,,,3„, .7 /•,7 4 r r' . '4 / 4kIT ...,..-.r' 0 . k..I 1 7 1 * / '' / --t9-7-•',,i,l .,- ' •. / ......... l '.” / 4tfil....... ........ ....'.. r. ., r r' / '' / . • . -..,"-- ' / . f /. ........' , I 1 isi i 1 ../ \\ 1 N ( FM IIF41 A I i . -; amr, 1 f um ..,.,...,,,t - -:: I 7/ ,.? I \ wa) ito ,,... , -----7-1-U1' I .":" iiiiiiiiiii-AT— - ;\ . 0,...:.-.... : I t•-•.--• ....7.7.72.11141-_.... i, -, imm7—izj,omm! .; .Mt •.-- 1‘. I''..- - ' LIAM ;...,',1 1 ilir.11111Lja Mali 1 h .... um- /0 1 sr , IMM 1 Imo= , • APii .„ i .. 044 .A Ntalikt..... ,_,',its..: 1111N4441411—7ffelfr.6 i. rifirAllik - 1 ' .-11k1.41411, . 0' 7;.-.4114116ZW' 9"111f:*fir 1 rig IC 41411 -* -7' ;0 i' i'ilt.4114111P W41 A.0 ,k4fri.ir"Ilik A'i .•:!,,e;,,,,,, '"'IL 41,,,,/ it, _ ,,, , ...0›,,,,,,,,--,,,,, ' fi: `ii - 417..,1• IfiV,7406.-‘4'4 Sliwt '''',-' , '• eimegV-=‘10004%, LA‘ffs ._-,/,. ,,,,,,„,.- fliv-41.--'4.„,---4,47ot - - --`4--40/6 61-',' ,-.41.1 ,..,a-';',44-' =-7‘. .1-.\ -44 0.74111T- .•'Ca •146=''f'le 0-- ,.... , Ar7,46......1111 , 2 NEI CI- '11_ swmi @Pori ., a i•,..1 1V). WI ,"/ ..,.. CO ma Nillirl IfL` 6,- ',„ ,.. , --- \\SIEET • s„ , ,„,-- , ,. ; — / -PieUtat IN 1 fr -' , • \ ,, , -..._.....-- „„„,...--- \ N \ „ • b 11 ge lore. - LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION �m ),� PROPERTY LEGAL: J JCih C, 1 3 i& 11C�-hC c �Qr r Au DATE OF SURVEY: 8I LATEST REVISION: V O z a DOCUMENT STANDARDS / ❑ 0 • Registered Land Surveyor signature and company 0 ❑ • Building Permit Applicant ;ir ❑ 0 • Legal description , ' 0 0 • Address .� ❑ ❑ • North arrow and scale Z 0 0 • House type(rambler,walkout,split w/o,split entry, lookout,etc.) fd' ❑ ❑ • Directional drainage arrows with slope/gradient% $ ❑ ❑ • Proposed/existing sewer and water services&invert elevation X 0 ❑ • Street name .PJ 0 0 • Driveway(grade&width-in RM/and back of curb,22'max.) f 0 0 • Lot Square Footage • ❑ ❑ • Lot Coverage ELEVATIONS Existing $9 ❑ ❑ • Property corners ❑ ❑ • Top of curb at the driveway and property line extensions / ❑ ❑ • Elevations of any existing adjacent homes ❑ 0 • Adequate footing depth of structures due to adjacent utility trenches 0 7 ❑ • Waterways(pond,stream,etc.) Proposed $9 ❑ ❑ • Garage floor X 0 0 • Basement floor / 0 0 • Lowest exposed elevation(walkout/window) $9' ❑ ❑ • Property corners J" ❑ ❑ • Front and rear of home at the foundation Y 1 • PRV Required PONDING AREA(if applicable) ❑ 7 ❑ • Easement line ❑ fd 0 • NWL ❑ 7 ❑ • HWL ❑ $f ❑ • Pond#designation ❑ ❑ • Emergency Overflow Elevation o ,Ef • Pond/Wetland buffer delineation Y • • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS • 0 ❑ • Lot lines/Bearings&dimensions p' ❑ ❑ • Right-of-way and street width(to back of curb) f' ❑ ❑ • Proposed home dimensions including any proposed decks,overhangs greater than 2', porches,etc. (i.e.all structures requiring permanent footings) p' 0 0 • Show all easements of record and any City utilities within those easements ,L( 0 0 • Setbacks of proposed structure an ideyard setback of adjacent existing structures X 0 ❑ • Retaining wall requirements: f Reviewed By: Date '4 G:/1 Engineering/FORMS/Cert.of Survey Checklist Rev. 11-16-16 4429-O69 (ZS6) '.XVJ 4409-069 (Z96) :3NOHd I cp L££S5 NW '3Tl1ASNanB 'o}oseuUW4 '/(}uno0 0}07100 'NO11100`d rn O 'on 3UflS 'Zi, OVOm JLLNl0O 1S3M 0092 Hit HiVd V10)iV0 `£ 110018 'S 101 m Z J o Zip O SHOA3Adf1S / S833NION3 / Sd3NNYldgL — �� 'N OX Q _ o 0 a Q% v o 93u ` I i saws 2J0� D \ s 1:1 M M W ISH I' ArnZInS AO aLVOr 3 ° N +, O C3EoII � c `°a� iLL O (1, O .n rO ` -0 -CUr6 OC '^ +,Qc NiO N• s_ ± E O t x Ta o Oh 2 `-^ o N > O N 30 U O O N u 40 CU O N O > > c v E Q co a s {l �Tv} U C C N N ++ +"' t6 06 ,.l o O C C L rO -p N Q .X O. -� N I I Q I?J O N a. O 7 O_ v v v "O N no O m O `n -0 O +t., ^4 Y C E � C +O+ ++ U N - M � 3 N 2 o ro ,° o u 0 0 c , ° E z NI N _o v 0 Cr v co m 1.0 a0i v z _ •i C O i O N Ili cr; vi i?. O t, I : HIE vL co (43 •v 7vraz _ s a cp E t O o 0 I- Q d' LO lD CL N O ro N ' 4- i N rn O ~ N N. -p 0 D II II II O +, 0 a0 Ct a W w al o c Q ° v E a`rsi ti N Q Z U k 1- -° c Q U Q CC v w •� � o +T, n .., >, w > 1,-3. 0 ro O Ct ,v1 Q 0 r° � °' O 1 > ca N CO — N ro 0� w u W2 W D v o O ria v m ° Q o U u U cz .o vru if c D Q Q C E O v c u▪ a� j tiD o f6 0� O C.° > w 0 0 O n O p O 0 N N O v= ++ O v= -p O1 -0 Q i m — d +� t LZ rr� > ao '� ci a • o L N v ao o a W @J m j ami Q rO_' v Sa o o E • u • a c a v n a ria Z 4 t I j `o a 45 o O r��o O rn v v N _ ix o Ti,ara - i E = m o Z o ° O 0 ° U 03 >. •>' °�' +� � E s W LU +, N O c +, ._ O = t O c :• _ ra _ = }, ct u- F- L.. C7 ro W LU >. u +' 0� +� +, 1r. Li m C w mm az = +, z 0 +, a ac7Lna U O v vim +, va- o c a0 ao a) H 0 a- 3 ) > -in •� O o c -0 .... 0 O i O ,' 1— Z O ro ra w a N N .� fY L -0 ,o i 3 a) Ct 0 m O W 0 J o 0 0 o Q 0 '� Q O 2 >. 3 re-2 oon cc. Q. J 0_ ,--I Z t--I N cf.; 4 L.rl ti, N 00 ) I— 11 L9 C7 S J = J 2 0 O W _ E . N Ln ....:,G I .,wy gg� 's 'y [� `•. In O ,-- 4 / .1- 0 --•O O Y Y N I� J-\.. / I \,`* �, i CO LO Q�(r.-.3 I tv 1\_,E-\\...., A `k` ', ao II II / / 0 �Ivv .Iv / \ w� 411 ' 1 ;:, \ / ca i-J \ m N W I I ' 9 4z c10 41 = \ \ p1 I`‘ "' A 5L'Z9 M«Z0,61o00N w 4 (f) ;1*. \ Enr" L'9LOIto c•9Lol £'9LOl ,' 9'6901 _ in - r•l'0 /\ Ol --OS'Zl OS•Zl-';- QZ �i ti,� S • \ ' ;;; \ 6"SLOT /�0'�7 "SCOL 0 d 1� si at s \ \ O \\O I 00 1 I-_1 N I O r �Q o o I mo I �0_ p ' HZ'S p > p w0•Z Q fx SOLO IX 0' x,,— ai n tiwe\_NOWI 0_0: v �c� 0 81\ a� o '(i O \0 0_0 M CC d 11 ^ Li.CD Z iv �\ \� \ Z'9LOLI -- - -I \o I +� 1� c o 1 N ' I Z w i 14 C J L9.9• _ \° Qtn� W C M c E - cu C o \ w U M �\W OY O `� L71W N W v c x ro O �, o O ° 0 J •d 034 n 011 In E CO = S in ma 0 D\ -F 6 o IL • O -0 ro CO'J > Q V 0,2 a w < O �\ _ O o E o -o -cr.) r O r.. CO • 0Z a \ Ol c \ \ • l •• eires L94 r?a vOo C O, l ` n ZOZt� 00(n C C -c O_ O .4 o. xLL I CO vi v _�30 I I nv ° a a t11)4E \ `y di I ISOO . Cccc C N N N N O N N N N I\ DDD 00000 -.-0(1.SO '` +PLOI 08901 in I� \ -u ' _-CZ.690L 100 _, _ 00Z )41 O o o ci O • x om °l '""....4 t o 83 i.4 M— Dirb o wLp Q �, � OLZ'�2MZ06 � OON 'SLOIC (LS90 l)x , o — M o`� 1. sox xi,ZLOI N U _ I La I-O II -0 \.....----- 30---1 mow Z ^ I ,� a - - I-\ In M 00 - - - 0 ¢ELn o O \ m Li— x cc Y xU II F— � Z.W J \ 0 ; Q_ 0. D ao�w I3\ �w Q Z z .:•4:111 E<:, \ o� Q U v) O A g�,2 12.91,2' RECEIVED REF. ■ ,`ea, JAN 2 2 2019 3_ _(2)1314 x14 VERSA-LAM _ _2$ (2)2)(10 a PLASH _._._._ _ ._.FLU ._._- -� tkl Fe- IAIIR." .- ,'.T. 'i1.t _ 2-4 ® • _ z¢ O _ kr ii z.,, ITT! 1 d--- •2'. SETATTO I�/,•/:4•M 2x10 rts cP - 7-.-.., 2'o -r 4 -r 4'-8117 4, •u• : I - - 4 ,� _ FLUSH BEAM _ _ N 1)1314 x14VERSA4AFA ;.tji ' ■ ,I 2-4ffrill.111111ME24••i1 � z 4a 10'TREAD CL4 t I. vigil MAIN LEVEL BEDROOM OPTION w Z I hereby certify that this plan, specification or report -- was prepared by me or under my direct supervision -- and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed: 74,171-hd Print Name: Nick Hanson Date: 1 -17-19 License Number: 46665 3 .7,v ritg, ti ft'-f Mi ML, EP121.N 7 - ' WED .y.______R,-7-- -...-_-_ -,-! ,, , , „,,, ,,,., , ,,,,, ), ,P / structured engineers YONS z s'07 Kilmer Lane N Suite 4 Plymouth, MN 55441 Tel 612-708-3572 www.hansongroupmn.com ¢ PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA153971 Date Issued:02/06/2019 Permit Category:ePermit Site Address: 1314 Interlachen Dr Lot:5 Block: 3 Addition: Dakota Path 4th PID:10-19543-03-050 Use: Description: Sub Type:Residential Work Type:Underground Sprinkler System Description:PVB Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Fee Summary:PL - RPZ/PVB/Lawn Irrigation $59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Dr Horton Inc Minnesota 20860 Kenbridge Ct Ste 100 Lakeville MN 55044 Sabre Plumbing Heating & A/c Inc 15535 Medina Road Plymouth MN 55447 (763) 473-2267 Applicant/Permitee: Signature Issued By: Signature O.!F E "'d...,40,.......4,........... O 0 , 3830 Pilot Knob Road I Eagan MN 55122 Phone: (651)675-5675 I Fax: (651)675-5694 buildinginspectionst cityofeagan.com Address: 1314 Interlachen Dr Permit#: 152887 The following items were /were not completed at the Final Inspection on: 01/X1 /t0 Complete Incomplete Comments Final grade - 6"from siding S,unw V'4M1d Permanent steps — Garage t/ Permanent steps— Main Entry V Permanent Driveway Permanent Gas r Retaining Wall or 3:1 Max Slope Sod / Seeded Lawn Trail / Curb Damage 5/149W Ca(411441 Porch 7 Lower Level Finish V Deck Fireplace / Q /11A1ii • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: I / (1/410I