Loading...
4182 Summerbrooke Pl 61._ 1-, (0, A-5 11 ,4?b.,(-P - et, pcoi- o /L7 , 1 J/ t�S(� % For Office Use \����( / I , E AG A ,,, ; ; %,/ � la l V � ermit#: I J V� I li,(Pao, (- ) i (- 6I) Permit Fee: I, IttiDO. I y,.g ,►' Date Received: -/ I A 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 * I (651)675-5675 I TDD:(651)454-8535 I FAX:(651)675 ` 5 94 l l'a.4 1 ,,,,,,I Staff: buildinginspections(acitvofeagan.com i t`. `.. 4 i J L-` ,i L J ' n2019 RESIDENTIALf L = % - -� IT APPLICATION A p.-?- Date: 6-- 2-1c' Site Address: '7 1 S StirAl/AaLe,Roo1LL' F1' ,,,G, Unit#: Name: Youngfield Homes dba Country Joe Homes Phone: 952-469-4066 Resident/ 22260 Dodd Blvd, Lakeville, MN 55044 Owner Address/City/Zip: a Applicant is: Owner ✓ Contractor /— /(PT) 5{�fg b�oo4- 0 Description of work: New Single Family Home L0/. hoc, / Type of Worki Construction Cost: 33 I 155". 4- Multi-Family Building:(Yes /No ✓ ) Company:Youngfield Homes/Country Joe Homes Contact: Steve Sauber Contractor Address: 22260 Dodd Blvd city. Lakeville 952-380-8120 Email: ssauber@countryjoehomes.com State: MN Zip: 55044 Phone: License#: BC627670 Lead Certificate#: If the project is exempt from lead certification, please explain why: New Construction COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING 1 In the last 12 months,has the City of Eagan issued a permit for a similar plan based on a master plan? `Yes X No If yes,date and address of master plan: I Licensed Plumber: Air Mechanical Inc Phone: 763-746-3767 Mechanical Contractor:Air Mechanical Inc Phone: 763-746-3753 Giles Brothers Excavating 612-366-4995 Sewer&Water Contractor: Phone: Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.com/subscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.qopherstateonecall.orq I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval o xSteve Sauber x tijgnatur 4Applicant's Printed Name Applicant's Lit $).. 5,,,.._,,a, 67)6k e l , is-toi-01 DO NOT WRITE BELOW THIS LINE SUB TYPES _ Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) X Single Family _ Garage _ Porch(4-Season) Exterior Alteration(Multi) _ Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex Lower Level Pool Accessory Building WORK TYPES New _ Interior Improvement _ Siding _ Demolish Building* Addition _ Move Building _ Reroof Demolish Interior _ Alteration Fire Repair Windows Demolish Foundation Replace _ Repair Egress Window Water Damage Retaining Wall *Demolition of entire building—give PCA handout to applicant DESCRIPTION Valuation 4 0//69 is Occupancy 3-pL-1 MCES System Plan Review Code Edition yY11\2.01 S SAC Units (25%_ 100°/ ) Zoning /t-I City Water Census Code Stories 2 Booster Pump #of Units Square Feet /&( 2- PRV #of Buildings Length S' Fire Suppression Required Type of Construction U 3 Width S 2 REQUIRED INSPECTIONS y Footings(New Building) Meter Size: Footings'Med() Final I C.O. Required Footings (Addition) Final I No C.O. Required )o Foundation >4 Foundation Before Backfill HVAC_Service Test Gas Line Air Test_Hood Roof: Ice&Water Final Pool:_Footings _Air/Gas Tests _Final 'D Framing 30 Minutes y4 1 Hour Drain Tile Fireplace: Rough In )6 Air Test )4 Final Siding:_Stucco Lath 24 Stone Lath _Brick_EFIS )° Insulation Windows Sheathing Retaining Wall:_Footings_Backfill_Final X Sheetrock r Radon Control Fire Walls Fire Suppression: _Rough In_Final Braced Walls }o Erosion Control )b Shower Pan Other: Reviewed By: / OM V' ' % '7 I9 , Building Inspector RESIDENTIAL FEES Loweg. I-e r e l i=:r,;S H e c / ' 5' /T (qs•7 3) Base Fee Lowe 12- Leel vn(;t1:514 -2 45(/ t'i6 � � Surcharge f17onT pozc+i q S 59 • it CSD .0,) Plan Review inti;/1 44 Z ”'. `f ( S. -) 3) MCES SAC a n D f 1 ooh 15- 3 S9 . 14•74- (95 -)3) City SAC G-- A R✓+`)e. ID s9 • Fr <<(o. y/) Utility Connection Charge S&W Permit&Surcharge Treatment Plant Copies TOTAL Page 2 of 3 I c(PAS New Construction Energy Code Compliance Certificate Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution Date Certificate Posted /�/� 1/�/�j/ �/� panel. 6—ii—/9 Io Mist UA11!/PAI l MIP panel. Address of the Dwelling or Dwelling Unit 4182 Summerbrooke PI City —71111 I���f.Vt iW�IVAi.II VW Eagan HEATING,COOLING& PLUMBING Name of Residential Contractor MN License Number BC627670 "Creating Custom Comfi)rl"Si1u'e 1985 Country Joe Homes THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply Passive(No Fan) S a, Active(With fan and monometer or a 2 other system monitoring device) N T Location(or future location)of Fan: @ _ T C N dU N a) o o_ 3 - U Fp o -o E Oarom -oU9ana) VN 8 a) O aUT Insulation Location g z m m c� O u- w N <fl 0 6) 6) E E N a a a) — F- z E ii u w E b' Other Please Describe Here Below Entire Slab x Foundation Wall R-15 X Perimeter of Slab on Grade x Rim Joist(1st Floor) R-20 X Rim Joist(2nd Floor+) R-20 x Wall R-21 X Ceiling,flat R-49 X Ceiling,vaulted R-49 X Bay Windows or cantilevered areas Floors over unconditioned area R-30 x Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: 0.29 X Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 0.28 R-8 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Domestic Water Appliances Heating System Heater Cooling System X Not required per mech.code Fuel Type Natural gas Electric Electric Passive Manufacturer BRYANT Westinghouse BRYANT Powered Interlocked with exhaust device. Model 912SC48100 WEG100C2045 BA13NA048 Describe: Input in 100,000 Capacity 100 Output 4 Other,describe: BTUS: in Gallons: in Tons: Rating or Size AFUE or 92% SEER 13 Location of duct or system: HSPF% /EER Efficiency Heating Loss r Heating Gain Cooling Load Residential Load Calculatic76,593 31,548 42,089 Cfm's "round duct OR MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech.code Select Type RENEWAIRE EV-300(BALANCED) Passive Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: X Energy Recover Ventilator(ERV)Capacity in cfms: Low: 150 High: 300 Location of duct or system: Balanced Ventilation capacity in cfms: FLEX MECH ROOM Location of fan(s),describe: Cfm's Capacity continuous ventilation rate in cfms: "FLEX OR Total ventilation(intermittent+continuous)rate in cfms: "metal duct Builders Associaton of Minnesota version 101014 • HVAC Load Calculations for • Country Joe Homes 4182 Summerbrooke PI Eagan, MN 55123 Prepared By: Samantha Lykke Air Mechanical 16411 Aberdeen St NE Ham Lake, MN 55304 Tuesday, May 21,2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads EliteSoftwareDevelopment,In Air Mechanical Inc. Hein Lake,.MN 5$3_04 Page 2 Project Report 16 .., _', t rte"». ZALq���� T'�f:;%-`'x 4 m W 'd.. Project Title: Project Date: Tuesday, May 21, 2019 Client Name: Country Joe Homes Client Address: 4182 Summerbrooke PI Client City: Eagan, MN 55123 Company Name: Air Mechanical Company Representative: Samantha Lykke Company Address: 16411 Aberdeen St NE Company City: Ham Lake, MN 55304 f u� _ � �� , �n ,t �ate.r ��,. � :r ,47 Reference City: Minneapolis, Minnesota Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 n/a 30% 72 29.40 Summer: 88 73 50% 50% 74 37 Zela lam., .1" P ,1 5, ., Total Building Supply CFM: 1,406 CFM Per Square ft.: 0.286 Square ft. of Room Area: 4,917 Square ft. Per Ton: 1,402 Volume (ft3): 31,197 ". ;1 `ilii •tea. Total Heating Required Including Ventilation Air: 76,593 Btuh 76.593 MBH Total Sensible Gain: 31,548 Btuh 75 % Total Latent Gain: 10,541 Btuh 25 % Total Cooling Required Including Ventilation Air: 42,089 Btuh 3.51 Tons(Based On Sensible+ Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\slykke\Desktop\4182 Summerbrooke Pl.rh9 Tuesday, May 21, 2019, 1:15 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. Ham Lake,MN_55304 Page3. Miscellaneous Report T Outdoor Outdoor Outdoor Indoor Indoor Grains ( `e D-ta`` Dry Bulb Wet Bulb ReLHum Rel.Hum Dry Bulb _Difference Winter: -15 -12.38 100% 30% 72 29.40 Summer: 88 73 50% 50% 74 37.40 rig Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside"Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 192 CFM 99 CFM Infiltration Actual: 0.313 AC/hr 0.000 AC/hr Above Grade Volume: X 31.197 Cu.ft. X 31.197 Cu.ft. 9,763 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 163 CFM 0 CFM Total Building Ventilation: 103 CFM 103 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 14.94 = (1.10 X 0.970 X 14.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 24.67 = (0.68 X 0.970 X 37.40 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(192 CFM), Construction:Average Summer Infiltration Specified: 0.190 AC/hr(99 CFM), Construction:Average C:\Users\slykke\Desktop\4182 Summerbrooke PI.rh9 Tuesday, May 21, 2019, 1:15 PM • 1 lwac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. m Lake MN 55304 W pagg_4 Duct Size Preview Room or Minimum Maximum Rough. Design SP Duct Duct Htg Clg Act. Duct Duct Name Qource Velocity Velocity Factor L1100 Loss Velocity Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Lower Level Built-In 0 750 0.01 0.1 424.5 214 P 250 3--6 2-Mian Level Built-In 0 750 0.01 0.1 397 356 637 6--7 3-Upper Level Built-In 0 750 0.01 0.1 388.6 301 519 5-7 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 887.9 872 j 1,406 12x19 Summary System 1 Heating Flow: 872 Cooling Flow: 1406 C:\Users\slykke\Desktop\4182 Summerbrooke Pl.rh9 Tuesday, May 21, 2019, 1:15 PM Rhvac-Residential& &Light Commercial HVAC Loads` Elite Software 6evelopment,Inc. r--- Air Mechanical Inc. Ham Lake;:MN 55304 Fagp5_ Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure) Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 1,662.0 sq.ft. Supply Air: 250 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.1 AC/hr Volume: 13,296 cu.ft. Req.Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 25 CFM Runout Air: 83 CFM Percent of Supply.: 10 % Runout Duct Size: 6 in. Actual Summer Vent.: 18 CFM Runout Air Velocity: 424 ft./min. Percent of Supply: 7 % Runout Air Velocity: 424 ft./min. Actual Winter Infil.: 19 CFM Actual Loss: 0.113 in.wg./100 ft. Actual Summer Infil.: 0 CFM e 4 Area Htglp c �, __.._ ' �__Quan itt Valtie� rHTM`F� ' Loss N -Wall-15B0-10sf-8 51 X 8 408 0.050 4.4 1,775 0.0 0 0 E-Wall-1560-10sf-8 46 X 8 368 0.050 4.4 1,601 0.0 0 0 S-Wall-12F-Obw 51 X 8 346.8 0.065 5.7 1,961 0.6 0 216 W-Wall-1560-10sf-8 46 X 8 368 0.050 4.4 1,601 0.0 0 0 S-GIs-4a shgc-0.28 0%S 26.2 0.290 25.2 662 16.8 0 441 S-Gls-4a shgc-0.28 0%S (2) 35 0.290 25.2 884 16.8 0 588 Floor-21A-20 1 X 1662 1662 0.027 2.3 3,904 0.0 0 0 Subtotals for Structure: 12,388 0 1,245 Infil.:Win.: 18.6, Sum.: 0.0 408 4.240 1,730 0.000 0 0 Ductwork: 470 0 AED Excursion: 128 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 1,200 2,200 LJghtir _ 450 _ 1,535 Room Totals: 14,588 1,400 5,337 C:\Users\slykke\Desktop\4182 Summerbrooke Pl.rh9 Tuesday, May 21, 2019, 1:15 PM Rhvac`-Residential&Light Commercial HVAC Loads is Elite Software Development,`Inc. Air Mechanical Inc. Ham Lake-MN 5;304 Page_6 Detailed Room Loads - Room 2 - Mian Level (Average Load Procedure) ;G� ti1;:`, .,r rc . .,1.ar ;;Zif�a.„.:�, 54w,, � u.1, s 0;rIfar�,,;SL;277:1z:; . n�,tee"vrjita✓"�� rt" Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 1,662.0 sq.ft. Supply Air: 637 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 14,958 cu.ft. Req.Vent. Clg: 0 CFM Number of Registers: 6 Actual Winter Vent.: 42 CFM Runout Air: 106 CFM Percent of Supply.: 7 % Runout Duct Size: 7 in. Actual Summer Vent.: 47 CFM Runout Air Velocity: 397 ft./min. Percent of Supply: 7 Runout Air Velocity: 397 ft./min. Actual Winter!nth.: 80 CFM Actual Loss: 0.080 in.wg./100 ft. Actual Summer Infil.: 0 CFM . ✓ " 0 � ✓A ci " , ° * k� ' �,0 - . i 7 x « pg �t}er0 ' 0"10000000.000.00070000-0 y om $ r ' k " ? ' w".0 ,y� ` ` ` � " X4,��g% -t eDappJ�oi�.6,� C Ga? ,b, uS` rox,do ntf i � vat Fice6' ME,0%" 0�txM ,00P11crliii e N-Wall-12F-Obw 51 X 9 382.5 0.065 5.7 2,163 0.6 0 239 E-Wall-12F-Obw 46 X 9 380 0.065 5.7 2,149 0.6 0 237 S-Wall-12F-Obw 51 X 9 298.5 0.065 5.7 1,688 0.6 0 186 W-Wall-12F-0bw 46 X 9 404 0.065 5.7 2,285 0.6 0 252 N -Door-11 N 3 X 7 21 0.350 30.5 639 8.8 0 184 N -Door-11G 3 X 7 21 0.540 47.0 987 13.5 0 284 N -GIs-4a shgc-0.28 100%S 7 0.290 25.2 177 9.4 0 66 N-Gls-4a shgc-0.28 100%S (2) 27.5 0.290 25.2 694 9.4 0 258 E-GIs-4a shgc-0.28 0%S 26 0.290 25.2 656 30.2 0 786 E -GIs-4a shgc-0.28 0%S (2) 8 0.290 25.2 202 30.3 0 242 S-GIs-4a shgc-0.28 0%S (2) 27.5 0.290 25.2 694 16.8 0 462 S -GIs-4a shgc-0.28 0%S (2) 49.5 0.290 25.2 1,248 16.8 0 832 S-Gls-4a shgc-0.28 0%S (3) 49.5 0.290 25.2 1,248 16.8 0 831 S-GIs-4a shgc-0.28 0%S 4 0.290 25.2 101 16.8 0 67 S -GIs-4a shgc-0.28 0%S (2) 30 0.290 25.2 756 16.8 0 504 W-GIs-4a shgc-0.28 0%S 10 0.290 25.2 252 30.2 0 302 1 UP-Ceil-16B-44 69 X 1 69 0.022 - . 1.9 132 1.1 0 .._ 74_ Subtotals for Structure: 16,071 0 5,806 Infil.:Win.: 79.8, Sum.: 0.0 1,746 4.241 7,405 0.000 0 0 Ductwork: 782 0 AED Excursion: 325 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 3,200 4,200 Lighting: 820 2,796 Room Totals: 24,258 3,600 13,587 C:\Users\slykke\Desktop\4182 Summerbrooke Pl.rh9 Tuesday, May 21, 2019, 1:15 PM Rhvac-Residential&Light Commercial HVAC Loads EliteSoftware Development,Inc. Air Mechanical Inc. • Ham Lake,MN 55304 — - — - — — Page 7j [etailed Room Loads - Room 3 - Upper Level (Avera_q_e Load__Procedure_)_ Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: n/a System Number: 1 Room Width: n/a Zone Number: 1 Area: 1,593.0 sq.ft. Supply Air: 519 CFM I Ceiling Height: 8.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 12,744 cu.ft. Req.Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 36 CFM Runout Air: 104 CFM Percent of Supply.: 7 % Runout Duct Size: 7 in. Actual Summer Vent.: 38 CFM Runout Air Velocity: 389 ft./min. Percent of Supply: 7 ok Runout Air Velocity: 389 ft./min. Actual Winter Infil.: 64 CFM Actual Loss: 0.077 in.wg./100 ft. Actual Summer Infil.: 0 CFM E'"1 -ems Y �� Area U- Htg` > * � fA,p;� 1 f e . Quantity _ 'Value HTM Loss ' H M :. if1 N a :°e f N -Wall-12F-Obw 50 X 8 328 0.065 5.7 1,855 0.6 0 205 E-Wall-12F-0bw 38 X 8 304 0.065 5.7 1,719 0.6 0 190 S-Wall-12F-Obw 50 X 8 339 0.065 5.7 1,917 0.6 0 212 W-Wall-12F-0bw 38 X 8 289 0.065 5.7 1,634 0.6 0 180 N-GIs-4a shgc-0.28 100%S (2) 27 0.290 25.2 682 9.3 0 252 N-Gls-4a shgc-0.28 100%S (3) 45 0.290 25.2 1,134 9.3 0 420 S-GIs-4a shgc-0.28 0%S (3) 45 0.290 25.2 1,134 16.8 0 756 S-GIs-4a shgc-0.28 0%S 16 0.290 25.2 404 16.8 0 269 W-GIs-4a shgc-0.28 0%S 15 0.290 25.2 378 30.2 0 453 UP-Ceil-16B-44 1593 X 1 1593 0.022 1.9 3,049 1.1 _ 0_ ___ 1,717 Subtotals for Structure: 13,906 0 4,654 !nth.:Win.: 64.3, Sum.: 0.0 1,408 4.241 5,972 0.000 0 0 Ductwork: 662 0 AED Excursion: 265 People:200 lat/per, 230 sen/per: 4 800 920 Equipment: 2,200 3,200 Lighting: 600 2,046 Room Totals: 20,540 3,000 11,085 C:\Users\slykke\Desktop\4182 Summerbrooke Pl.rh9 Tuesday, May 21, 2019, 1:15 PM --- ---- Rhvac-:Residential&Light Commercial HVAC Loads Elite`�re D itat`i Mtn,' Air Mechanical Inc. °" '' _Ham Lake,MN 55304 _ __ �__ . ______ _ _____ — _-,— P.. System I Room Load Summary .ad • p 4 B E 4.'41"Tilid44''''''r / Iii Ad 'die- gy=p :,< c, 4 ' ---Zone 1--- 1 Lower Level 1,662 14,588 214 3-6 424 5,337 1,400 250 250 2 Mian Level 1,662 24,258 356 6-7 397 13,587 3,600 637 637 3 Upper Level 1,593 20,540 301 5-7 389 11,085 3,000 5.19_ 519 Ventilation 9,564 1,539 2,541 Humidification 5,728 Return Duct 1,915 0 0 System 1 total 4,917 76,593 872 31,548. 10,541 1,406 1,496 System 1 Main Trunk Size: 12x19 in. Velocity: 888 ft./min Loss per 100 ft: 0.104 in.wg F` bltnct$stem Sur mart' Cooling Sensible/Latent Sensible Latent „ ' ®m na Tons S,)lit Btuh Btuh m ,�. � _ _ :. : Net Required: 3.51 75% /2.% 31,548 10,541 42,089 i•ment Data z 7 ' , `7 Heating System Cooling :._i ;le n Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Users\slykke\Desktop\4182 Summerbrooke PI.rh9 Tuesday, May 21, 2019, 1:15 PM pQ Q' O- O _ O -•L O _ _ O w - O0 c ,O c D 7' O a) N O O = c c `c E O -O O' O Q a) a h O a) O 0 _ 6 0 3 p t/7 o 13 c U Z 2 fi cN N 0 O • E O U • a) p. a) .E ..s a) a`a)) • 0 L v w O a CN O 0 U a) O-c O U � 3E,._0s ° g d � 5 � � -cTP) _c0 �� ° � a� m a) Ou R- �- c v' N O p 0 15 4) L c c A aj W N O Q 0) O O _ate s a� o E p � , ° UZ -p O) -° wa) c 3s c ° O cd o a) c o` - 0 .s o a�°i p O g m x a) O .>_ L Q ° Q c -a 4.. A O 0)s o a) n c a) = E rnM c MO a)3 3 o c co IN`c 0 Q pp y --0 nc b- E . N 6 43 O 0 0 0 J0 O a) a) Q U a) a) E n O U cs C a 3N e— _ 5 .0 c O n ( O T OAO bO • v)c . a �c � C 404EA i: s QOa> a) ei C00 O a8 'cOQO O - O Q-0 . ci. 0E c, r EUnoc CO U • 0 o_ : • .c 3 DE 00 Y. 71 • k E h � ` rot Pb12 1 2 v8 gr ,_. ,d.--, i . gi 1; igi VI 0 H � _ sr � x v aI w 50 � "-(4 �+ ~ �� amgo 0 u+ k J/ �< H iv °� F 5 as 9i a 0z 1ii a d3 0 ,no is z ° \� ° A d ,a \//\//\//\//\> 2 O . b ©8 1v' re> G; \. o � . III w2 '4Q M-,4 O6 %�\/\ r"A° �° LI ,�\issv �\\`v\\�\\` /\\ Q U Radon Reduction System ❑ Sub-floor Preparation o Add a 4" uniform layer of clean aggregate that will pass through a 2" sieve and be retained by a �/4" sieve ❑ G-mil poly over entire sub-floor o Lapped a minimum of 1 2" (previously c") 0 All punctures or tears must be sealed or covered with Poly ❑ Seal all entry points o Polyurethane caulk or elastomeric sealant on openings around bathtubs, showers, pipes, wires, etc. o Polyurethane caulk or elastomeric sealant on all concrete joints and the joint between the slab and foundation wall o Polyurethane caulk or elastomeric sealant to fill joints, cracks, or other openings in foundation walls o Gasketed sump lid is required ❑ Minimum 3" ABS or PVC gastight pipe o Must go from the sub-slab base and run all the way through the building floors and terminate at least 1 2" above the surface of the roof o Can be installed into the gravel with a "T" fitting. o If we install 10' of perforated pipe, can include elbows o Route the pipe through conditioned space o Locate the end of the pipe that terminates on the roof at least 10' from any window or other opening in the dwelling that is less than 2' below the exhaust point. The end of the pipe must also be at least 10' from any window or other opening in adjoining or adjacent buildings o There must be a minimum of 24" in diameter (pipe serving as the axis) around the pipe by a vertical distance of 3' to allow for the installation of a fan in the attic in case the homeowner chooses to change the radon ready system into an active radon remediation system 0 Label the Vent Pipe o At least once per floor * in accessible attics, the pipe must be labeled with the words ° "RADON REDUCTION SYSTEM" ❑ One electrical receptacle in the attic o Must be near the pipe where a fan would be located if the homeowner chooses to install an active system after construction ❑ Active System o An active system can be installed o With an active system you are required to install a continuously exhausting fan and monometer or other system monitoring device • Architectural Manager Page 4 6/8/2009 _AID lkI'uMINI I,P -ruff num """" '"i"" ' Ventilation, Makeup and Combustion Air HEATING,COOLING&PLUMBING "Creating Comm Comfort"Since 1985 Calculations Submittal Form For New 16411 ABERDEEN ST NE,HAM LAKE,MN 55304 Dwellings Site address 4182 Summerbrooke PI Date 5/21/19 Contractor Country Joe Homes Completed By Air Mechanical Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet(Conditioned area including basement– 4917 Total required ventilation 205 finished or unfinished) — Number of bedrooms 6 Continuous ventilation 1 03 Directions -Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. The table and equation are below. Table N1104.2 Total and Continuous Ventilation Rates (in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space Total/ Total/ Total/ Total/ Total/ Total/ (in sq.ft.) continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space) + [15 x(number of bedrooms+ 1)] =Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators (HRV)and energy recovery ventila-tors (ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation -A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a con-tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. 1 • Section B Ventilation Method (Choose either balanced or exhaust) ✓[ alanced,HRV(Heat Recovery Ventilator)or ERV(Energy Eaxhaust only(Continuous fan rating in cfm) Recov-ery Ventilator)—cfm of unit in low must not exceed continuous venti-lation rating by more than 100%. Low cfm: ,�50 High cfm: 300 Continuous fan rating in cfm(capacity must not exceed continuous ventilation rating by more than 100%) Directions -Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Description Location Continuous Intermittent RENEW AIRE EV-300 Mech.Room Directions - The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100%greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls Directions-Describe operation and control of the continuous and intermittent ventilation. There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans are used for building ventilation,describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed, describe how it will be installed. If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures'installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation, such interconnection shall be made and described. RENEW AIRE Honeywell 2 Section E Make-up air Q Passive (determined from calculations from Table 501.3.1) Powered(determined from calculations from Table 501.3.1) Interlocked with exhaust device(determined from calculation from Table 501.3.1) Other,describe: NOT REQUIRED Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm Size and type(round,rectangular,flex or rigid) Directions -In order to determine the makeup air, Table 501.3.1 must be filled out(see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re-quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The make-up air supply must be installed per IMC 501.3.2.3. Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherically vent or direct vent assisted appliances and gas or oil appliance or vented gas or oil appliances appliances or no power vent or direct one solid fuel appliance or solid fuel appliances combustion appliances vent appliances Column A Column B Column C Column D 1. a)pressure factor(cfm/sf) 0.15 0.09 0.06 0.03 b)conditioned floor area(sf) 4 917 (including unfinished basements) Estimated House Infiltration(cfm): 737 [lax lb] 2.Exhaust Capacity a)continuous exhaust-only N/A ventilation system(cfm);(not applicable to balanced ventilation systems such as HRV) b)clothes dryer(cfm) 135 135 135 135 c)80%of largest exhaust rating(cfm); Kitchen hood typically(not applicable 240 if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) d)80%of next largest exhaust rating (cfm); bath fan typically(not Not applicable if recirculating system or if powered makeup air is electrically Applicable interlocked and matched to exhaust) Total Exhaust Capacity(cfm); 375 [2a+2b+2c+2d] 3.Makeup Air Quantity(cfm) 375 a)total exhaust capacity(from above) b)estimated house infiltration(from 737 above) Makeup Air Quantity(cfm); -362 [3a—3b](if value is negative,no makeup air is needed) 4.For makeup Air Opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may be included.) C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. 3 Makeup Air Opening Table for New and Existing Dwelling Table 501.3.2 One or multiple power One or multiple fan- One atmospherically Multiple atmospherically vent,direct vent assisted appliances and vented gas or oil vented gas or oil Duct appliances,or no power vent or direct appliance or one solid appliances or solid fuel diameter combustion appliances vent appliances fuel appliance appliances Column A Column B Column C Column D Passive opening 1—36 1—22 1—15 1 —9 3 _ Passive opening 37—66 23—41 16—28 10—17 4 Passive opening 67—109 42—66 29—46 18—28 5 Passive opening 110-163 67—100 47—69 29—42 6 Passive opening 164—232 101 —143 70—99 43—61 7 Passive opening 233—317 144—195 100—135 62—83 8 Passive opening 318—419 196—258 136—179 84—110 9 w/motorized damper Passive opening 420—539 259—332 180—230 111—142 10 w/motorized damper Passive opening 540—679 333—419 231—290 143—179 11 w/motorized damper Powered makeup air >679 >419 >290 _ >179 NA Notes: A.An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B.If flexible duct is used,increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D.Powered makeup air shall be electrically interlocked with the largest exhaust system. Section F Combustion ✓Q Not required per mechanical code(No atmospheric or power vented appliances) Passive(see IFGC Appendix E,Worksheet E-1) Size and type 6"INSULATED FLEX ED Other,describe: Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. 4 Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1--Residential Combustion Air Calculation Method(for Furnace, Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance information. Furnace/Boiler: IDDraft Hood QFan Assisted QDirect Vent Input: Btu/hr or Power Vent Water Heater: Ebraft Hood ED Fan Assisted EiDirect Vent Input: Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances.The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 0 ft3 Lx W x H L W H Step 3:Determine Air Changes per Hour(ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method). If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) 4a.Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft3 Volume(TRV)If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.If CAS Volume(from Step 2)is less than TRV then go to STEP 5. 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA: ft3 Required Volume Fan Assisted(RVFA) Total Btu/hr input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= 0 + 0 = 0 TRV ft3 If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.If CAS Volume(from Step 2)is less than TRV then go to STEP 5. Step 5:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio=0 /0 =N/A Step 6:Calculate Reduction Factor(RF). RF=1 minus Ratio RF=1 - 0 =1 Step 7:Calculate single outdoor opening as if all combustion air is from outside.Total Btu/hr input of all Combustion Appliances in the same CAS Input: 0 Btu/hr(EXCEPT DIRECT VENT) Combustion Air Opening Area(CAOA):Total Btu/hr divided by 3000 Btu/hr per in2 CAOA=0 /3000 Btu/hr per in2=0 in2 Step 8:Calculate Minimum CAOA: Minimum CAOA=CAOA multiplied by RF Minimum CAOA=0 x =0 in2 Step 9:Calculate Combustion Air Opening Diameter(CAOD): CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13'] Minimum CAOA= in.diameter go up one inch in size if using flex duct 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. 5 IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method (cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 _ 188 _ 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 _ 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 _ 4,463 90,000 4,500 _ 6,750 3,375 9,450 4,725 95,000 4,750 7,125 _ 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 _ 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 _ 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 _ 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1. The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2. This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. 6 EAGAN City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Summerbrooke 2nd Lot Number 6 Block Number 1 Address 4182 Summerbrooke Place Builder Country Joe Homes Email: ssauber(acountryjoehomes.com Contact: Steve Sauber Tree Protection Requirements: X Tree Protection Fencing To Be Installed on Site by builder Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: Not Required X As Follows: Seven (7) Category A trees (>= 4.0" caliper deciduous trees, or>_= 12' conifer trees) per approved Tree Mitigation Plan to be installed following construction (see attached Tree Mitigation Plan). Attachments: X Yes (Refer to atta7f iA ' P'silf' 'T RESTRY DIVISION No REVIEWS ! Additional Notes: BY f H:\ghove\2019fi1e\treepres\Tree Preservation Plan Summerorooke 2nd Add Let 6 Block 1 DATE U O 2 V W4.1 w 4 h N p t31 2 V W% lQy �`,Z,N'�, v❑i —I W U N j H. S� o o f h O °�° i E $ 'LL OO h 2 O y0. W 4 2 ch g n e w 4 < �' VI 2 y O W td 2 O z O 0 m v '- R Q. O W ti Q p W o i ❑ O Y,:.. ;.- 2 W M o o m rWy ,e o o $ ' z Z� ' oz O �' O l�k W 1 Z o; yp W T C! ' J tt3 y�� pp% tail O O �Shy^1y C.5.,44'� 4 J a O y m OCS P ¢ V W �}y- n�N�`' Q Pi �vL, y� iyga ,. ; i a :ti. < 1 Q 1 L' ter;II 1 J mho P P P P `OP P P '21- °z q 4 p o 0 0 0 0 0 D. of a L ti ' ti U . w' U . . R1,1- p,� II^ ant o — 1 1 c' r'� ni p P LIJ , 9o'626,59° "'� () 1.1ti x \, ,5 2 t,.142 �� P m . aig'; / `� LIJ .e '' P N J .O 1 P� - g �O �[ Vh) a `'- h CO J oma b (:) a Q /%. '/ . b m > x rr) o r y �7xw �x a V �YJ V 1 / II r b �� / 6 p -J 01 I Ye LO'ZS �N- sr/ ,...?•,1 sgt OOOI = h dif, O ° J / // (Ni ^ I0 P % P xPx E 1 ": ' N tel. lJ LI q c; off/ Fx P W} P I C c g W4c5 aq �� n A. ^ o V 1 • o ^ e i b b a U�'� b '6 x q P P y �� v x W m e e N O _ �� P eve Zi,', N O 2 it 1„l ' >o Po U' y e0 A Pq n OW 7 03 m �T w b6'OS q ® OOJ{e x I x P x x� _ ' x 1 " 0,_ in NI a .P n a Z \ OLBfr-7 P igt� o y m 00707-0 Nn —r w ®m N 1 Ei 11 ' i \ II`j' Z-, CI;q . ... ,.t. �x, b RQJHOZE1.00Y 0 - i g a q v- ex Z9F QNb § P y P a ¢ a' N \ P3:.., ' 05,•^vl \ O 0 HTaF+1 dM(17 JUe1ON(A 0'116 o y p) 5!f ) I 0 q st . 33V1d 3>iooea3W ins ' , i Q :IU:271NY1 Q = “-a E Q (1) E s r • _ ---2...----9 10_A . —--•In-- ---12,L...-2-.7-2.-__--------79r01--Z- \ „-. 1_11-:_ ,- g4170 =i--E----E--.,�---.:-_------_-=-7--9-:-:_2ap-t feV \ �`�' ”-- -7 7.— '' ._ --- / _ ( 'F,�. •\ .,s(' ` \il4it • 4$ •►' -1 T *,`\ t _, ,..,44, 1 \ )-----`\ / r: :,, �•;���,•�., .'7 1, \ i'p' NAllN— \ . i _ . a k ' ..e -s� , „. 0,,,,,,,,,,,„,„000 li . 4E.- , ,/ ---„:-.,-- t, -,... \..,..- ‘ ,,,.. .. \\''''t. .. .„,i...:\ ' #40\ ` ' 9 / ^i �\ -- . \L "\ \ 1, , . r ' il Ik , v _ ArT," \ � I / � q:',4t J, . .,• , . ,, , air. r 0 .41 :7:161` ,10,7. IP\ \I i "1 • t ' MER: ' \ 1�� 1: ) L s lV4.--.. 0 4 At Of , ______LL___::_-,( V . .....,. / < 1A J i • 40.43 ,f' - ,;i7 /„./r- ,zillli /111.4 .,•;-6,1=ii. kiiiii-.110 ,. ,,- ,- N. ` w mow► �� ''�t� ,,,, ;� . -�� �`. __- �I \`✓ ^Jk, r( - f C 1 .N 41111;ja.:.V//* i Akig1 /111/ cirri- -:ftILINI :::. - ,,.2/ ) -.TX 1111P . \ ii • .i ,- ' / yr (>//,y '• i . if 4/, 1 ---- ---- , . 9/6_, 4k0 I ,‘ t my, -...,, -Ty/ tut 1011gM!L‘ 1.Y. -•,. ..m...iimittEt / . - , '. ........i o r . y } :r . . a ,: gv ,f ViA MI Irria \ N 5 ---1�� i , : 1 r 'IiJth \ - ,, IF- O A �G/f P4 . , /{ .1. v\ r , ../ •-c• ,„4 • :....,„„... .......,,,„,....:,,,,, L. -' -� .\\ ', =7�' :',45� 1`.. moi, l" w it . 41N-_,1trilert.lird kg'iP il --.,•----.' •‘..- - 111110,64k).3 ItN404-14•6) .1 1\ 1 : (-- Illt.!.%i' VV.' V ,E,-,) '--, • / l \ \I \29 isib-f--- \:11t.!4'"—I.IN.*':14*-i. ,i c‘9`."-0\'' '''' - '\ „ \ • \ \ "1 �7 �� 1 ,_„, ., �� .. jl\:; \ ...,z-,--. .--2.----44- - ' y , .�►. !_j,� --4114:'.21119',' • jt� -A -a > *3k; . i V . , \ \---. _-moa t r • ��h 1 e•- \ 1 Ste ' ;� N c, 9 a s 1 EE MItiGATION CALCULATION DETAILS iiteato• /00Troee1 I Sail14INIO*Ift&Aw et4i'ieAt-PMbirtW Rnsl j.bMj ti LOT SURVEY CHECKLIST FOR RESIDENTIAL L�], I BUILDING PERMIT APPLICATION_ ' PROPERTY LEGAL: La� FI C J< 1, �A-01m—or IST c €_ 2� Rdd DATE OF SURVEY: 101.51/9 LATEST REVISION: a, !0 V Z DOCUMENT STANDARDS ,, ❑ 0 • Registered Land Surveyor signature and company ,a 0 0 • Building Permit Applicant •Et 0 0 • Legal description a 0 0 • Address _Pr' 0 0 • North arrow and scale .0 0 0 • House type(rambler,walkout,split w/o, split entry, lookout,etc.) a 0 0 • Directional drainage arrows with slope/gradient% • ❑ 0 • Proposed/existing sewer and water services&invert elevation .JZ' 0 0 • Street name .2' 0 0 • Driveway(grade&width-in R/W and back of curb,22' max.) ..e ❑ ❑ • Lot Square Footage • ❑ ❑ • Lot Coverage ELEVATIONS Existing 11 0 0 • Property corners 4 0 0 • Top of curb at the driveway and property line extensions O ,d ❑ • Elevations of any existing adjacent homes ,1 ❑ ❑ • Adequate footing depth of structures due to adjacent utility trenches yr' 0 0 • Waterways(pond,stream,etc.) Proposed ❑ 0 • Garage floor 4 0 0 • Basement floor { 0 0 • Lowest exposed elevation(walkout/window) 0 0 • Property corners y0 0 • Front and rear of home at the foundation 0 N • PRV Required PONDING AREA(if applicable) O 0 • Easement line ❑ 111 0 • NWL ❑ ❑ • HWL O X 0 • Pond#designation O PO 0 • Emergency Overflow Elevation o •7' • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS 0 0 • Lot lines/Bearings&dimensions 0 0 • Right-of-way and street width(to back of curb) 0 0 • Proposed home dimensions includingproposed decks,overhangs greater than 2', porches,etc. any (i.e.all structures requiring permanent footings) 0 0 • Show all easements of record and any City utilities within those easements 0 0 • Setbacks of proposed structu = and sideyard etback of adjacent existing structures y 0 0 • Retaining wall requirements: 1, Reviewed By AA Date /2-1,5,9s G:/1 Engineering/FORMS/Cert.of Survey Checklist Rev.11-16-16 1 v 2 Ct LA-LU6t ,z) W 0 X N zzi Z O Q 0 0) 0 w U N �� II W p j U z � � W 2 h U W w r 71 z r Z O p_ Z o j h O m } 0 v 2 ti W N� �. O J LL z ~ W k cc 2 CC oi�� Z V ¢ Q w J w O 01 W 2 0 W a j U rn II a I- to /� N j O 1 Z 144cn v, o °' II O Ah ¢ i I-5 ¢ z V/ oZ co W Q 2 0 p ~O m U II Nw Q a = J Zz � "Cr.: WLi_ W � � z �o aWz °az W a co O O '` p � W Q. Lu O �p� p w � z Q pzWL GI c� o� _ _o o oW 3i` cn p J2 Q i � W ���N� Wa a 5 0 O O m WWW O O = > _ 005Z W G 1- Et I- qr`14. IX NN^ II II j CO(f)1‘ ��� O 1 ai z II II O JOO ti 000 CL C�� 0 rn U �� Q�4, 0 0 0 0 0 0 0 0 PJ O � v II �� 2 2 2 2 2 2 2 0 ,, IIIdh W W W W W W W W •j o f O O O O O D O .� 1 co I . ti O � � W p � o CL W 0 0 6 i 0 „, _ D -I < U V0 II Nho 02 cx_ kII a,�n� II L' I (3 1.... II J ri N 0, W cc 1 WA elr5):II CI cy, k i ° o LI ) J/ 0 I j 7.1 \ 1--C „, , ., E.r 9 •16 5 s C) ..r d H o \ � x x `O> 11., ,s i a 1D m Zr.)- EYJ / 1 . 1 I� ` , Lire f rn �rro o 11— r^ LIJ I - 't I �? 11: ' °1 , rn CO N e— 3 o°° A �, I N a X / O CD O +' Nii en to 0 x Nilila .. � X ^ X > p / cn ( \ / ` in • Q N m ,! / - / V N Illiggli \ ,- �� i / -J (� ' / H Y 11111111 1 O °j O'--- -- CO O 91 1. NI. itj O \ w 9Fl N N - o \ a o xm x Ij�, �j ch f� x E I 11 1 - owl �`^ al rn Q y VN . 2 x o, cAagO o �, Q o 25 °, o, p.Q � � yN �� / L.� `�'O O I a N o • '` CnU (J sa 1 �,m- • CIO odQz `O (6 co xis: Lij , / 0— g cts " a °x X m 0) o, 6 LO LtIN 41:1 g 4:3 O ) 07 m ove '6;>1 O C7 N 00 �► �, O ,^ l9 11'1 O'ot 12',1`°c'' oY l °j O `r J ild ---13=01.- rn N O l - m m h II }605 N O = O a 10 \� O x O IAC <to X L roil a OZ = 1 X i h W Q co oS .- Zo Z OL '8f7=7 i ow - m Q � � \ N 0` Lf. -r J° I D W N�fi r,� 00•7 0J=GJ o v Z ��rn vJ y p N ^ n ^, ®°� N worn .: O h n - 0)02. O O m �N N vi ® c\--. ----x o'ZZ---1., U P M 25 a O F r o �� � a x �V N y �v, ",\V 'Z. .:' x ^ to 0� tci X ,OZ/BL.00N �� ^ ° ° = LLL 2 fl.• ca,mcm oma, o, ',- -- o'll -- °, °, (.•) ;w o �aun� ern al. 0. .its m CoC)(0 iii cr it:- 3V1d 3N00�182j3WW(1S �� a z QN a,z N — 3NITd31N20 — — __ c I' i �.�_ to LL O v O�` th . 0 V �_ O O N z L ,p ", o_ m E 0 pFE,Q `',V,:,........ . o A<isms° ' 3830 Pilot Knob Road I Eagan MN 55122 Phone:(651)675-5675 I Fax: (651)675-5694 buildinginspectionsOcitvofeagan.com Address: 4182 Summerbrooke PI Permit#: 156485 The following items were/were not completed at the Final Inspection on: a L' om IE 1� 1 �1,���,,, pis ple ' Comment$4 a Final grade - 6"from siding Permanent steps—Garage ✓ Permanent steps— Main Entry ✓ Permanent Driveway ✓ Permanent Gas Retaining Wall or 3:1 Max Slope ,(yi Sod / Seeded Lawn ✓ Trail / Curb Damage /1/1/4- Porch /1//A- Lower Level Finish Deck 4//1- Fireplace ✓ • Verify with your builder that roof test caps from the plumbing system have been removed. • Turn off water supply to the outside lawn faucets before freeze potential exists. • Call the Engineering Department at (651) 675-5646 prior to working in the right-of-way or installing an irrigation system. Building Inspector: Z.. --