Loading...
783 Summerbrooke Ct eL 1560407 - rOZ.O O 1/111 S�g6 - /00 ' For Office Use II .?, • , � , /Q 3o,p .gjs Permit#: E AG N gas Permit Fee:/Of RECEIVED 740.17Date Received: / 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651)675-5675 I TDD:(651)454-8535 I FAX:(651)675-5694 JUL 1 0 2019 Staff: buildinginspections(acitvofeaaan.com L LO / b b�l 2019 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 7 9'/9 Site Address: 7 3 SJ1/21,M1te440k COUgir Unit#: Name:Youngfield Homes dba Country Joe Homes Phone: 952-469-4066 Resident/ 22260 Dodd Blvd, Lakeville, MN 55044 Owner Address/City/Zip: Applicant is: Owner ✓ Contractor L6 �i t l d I , �n1 fD' IL(2� Description of work: • New Single Family Home J Type of Work q Q' Construction Cost: 42: y 10 . 13( Multi-Family Building:(Yes /No ✓ ) Company:Youngfield Homes/Country Joe Homes Contact: Steve Sauber Contractor Address: 22260 Dodd Blvd City: Lakeville State: MN Zip: 55044 Phone: 952-380-8120 Email: ssauber@countryjoehomes.com License#: BC627670 Lead Certificate#: If the project is exempt from lead certification, please explain why: New Construction COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING In the last 12 months, has the City of Eagan issued a permit for a similar plan based on a master plan? gi Yes No If yes,date and address of master plan: .1—? 7l!l 9� Stfivoiees k6 &Ara. Licensed Plumber: Air Mechanical Inc Phone: 763-746-3767 Mechanical Contractor:Air Mechanical Inc Phone: 763-746-3753 Sewer&Water Contractor: Giles Brothers Excavating Phone: 612-366-4995 Fire Suppression Contractor: Phone: NOTE:Plans and supporting documents that you submit are considered to be public information. Portions of the information maybe classified as non-public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notification from the City of proposed ordinances by signing up for an email update on the City's website at www.citvofeagan.comisubscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at(651)454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecall.org I hereby acknowledge that this information is complete and accurate;that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of work which requires a review and approval of XSteve Sauber Applicant's Printed Name Applicant's Signature • �03 Somo,e r bro k cJ /6ZS � R DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation _ Fireplace _ Porch(3-Season) _ Exterior Alteration(Single Family) v Single Family _ Garage _ Porch(4-Season) _ Exterior Alteration(Multi) Multi _ Deck _ Porch(Screen/Gazebo/Pergola) _ Miscellaneous 01 of_Plex Lower Level Pool Accessory Building WORK TYPES ?c,New _ Interior Improvement _ Siding — Demolish Building* Addition — Move Building — Reroof _ Demolish Interior Alteration _ Fire Repair _ Windows _ Demolish Foundation Replace _ Repair _ Egress Window _ Water Damage Retaining Wall *Demolition of entire building—give PCA handout to applicant 5 DESCRIPTION 3Valuation Occupancy I)4 ti ' MCES System Plan Review Code Edition 1', \1``..7/ SAC Units (25% 100% ) Zoning ;, City Water Census Code StoriesBooster Pump #of Units Square Feet i �_ PRV #of Buildings Length s Fire Suppression Required i Type of Construction 1 { , Width I li REQUIRED INSPECTIONS ik Footings(New Building) Meter Size: Footings(Deck) y Final I C.O. Required Footings(Addition) I' Final/No C.O. Required X Foundation Foundation Before Backfill HVAC Service Test Gas Line Air Test Hood I Roof: Ice&4ater Final Pool: Footings Air/Gas Tests Final Framing 30 Minutes1 Hour Drain Tile )( Fireplace: )(Rough In Air Test yr Final Siding: Stucco Lath Stone Lath Brick EFTS 7Insulation Windows Sheathing Retaining Wall: Footings Backfill Final Sheetrock Radon Control Fire Walls ! Fire Suppression: Rough In Final Braced Walls Erosion Control \[ Shower Pan Other: J� f- I By: , Building Inspector RESIDENTIAL FEES Base Fee6/61i ( 1'' f` : .- ){, >`i- -7 Surcharge — w.� N. r� ,N4 71 r Plan Review .1 1 _t ',ai ,` • l/ �I 7��i ��3 MCES SAC / 1 r / City SAC / L�' \I 1 - ) /70i,, ) l Utility Connection Charge / S&W Permit&Surcharge 61- S,' X 7L), 'I/ _ 65a k, I Treatment Plant Copies 1) / .._ .� TOTAL N..j r 1r o pi New Construction Energy Code Compliance Certificate Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution Date Certificate Posted panel. 6/12/2019._eID U tLURWAI IAS' Mailing Address of the Dwelling or Dwelling Unit City -rumnim/nieVl W UWi.III 111 783 Summerbrooke Ct Eagan HEATING,COOLING&PLUMBING Name of Residential Contractor MN License Number "Creating Custom Comfort"Since 1985 Country Joe Homes BC627670 THERMAL ENVELOPE RADON CONTROL SYSTEM Type:Check All That Apply X Passive(No Fan) o a) Active(With fan and monometer or na other system monitoring device) � a) Location(or future location)of Fan: T o G. A =0 4) o -p E NN -0 V -0 a) 7 Q m m cu ,_ N 'a C Tu: N OQz . . L O Insulation Location 0 co m 0 O - w N o o 2) Trp f_3 EE 175 -3 m 2 . z LT: ii: i b: ix Other Please Describe Here Below Entire Slab X Foundation Wall R-15 X Perimeter of Slab on Grade x Rim Joist(1st Floor) R-2o X Rim Joist(2nd Floor+) R-20 X Wall R-21 X Ceiling,flat R-49 X Ceiling,vaulted R-49 X Bay Windows or cantilevered areas Floors over unconditioned area R-30 X _ Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces Average U-Factor(excludes skylights and one door)U: 0.29 X Not applicable,all ducts located in conditioned space Solar Heat Gain Coefficient(SHGC): 0.28 R-8 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Cooling System Heater X Not required per mech.code Fuel Type Natural gas Electric Electric Passive Manufacturer BRYANT Westinghouse BRYANT Powered Interlocked with exhaust device. Model 912SC48100 WEG100C2X045 BA13NA042 Describe: Input in 100,000 Capacity 100 Output 3.5 Other,describe: BTUS: in Gallons: in Tons: Rating or Size AFUE or 92% SEER 13 Location of duct or system: HSPF% IEER Efficiency Heating Loss Heating Gain Cooling Load Residential Load Calculatii 81,724 26,879 37,316 Cfm's "round duct OR I MECHANICAL VENTILATION SYSTEM "metal duct Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type source heat pump with gas back-up furnace): X Not required per mech.code Select Type RENEW AIRE EV-200(BALANCED) Passive Heat Recover Ventilator(HRV) Capacity in cfms: Low: High: Other,describe: X Energy Recover Ventilator(ERV)Capacity in cfms: Low: 100 High: 200 Location of duct or system: Balanced Ventilation capacity in cfms: FLEX MECH ROOM Location of fan(s),describe: I Cfm's Capacity continuous ventilation rate in cfms: "FLEX OR Total ventilation(intermittent+continuous)rate in cfms: "metal duct Builders Associaton of Minnesota version 101014 l HVAC Load Calculations for Country Joe Homes 783 Summerbrooke Ct Eagan, MN 55123 Prepared By: Samantha Lykke Air Mechanical 16411 Aberdeen St NE Ham Lake, MN 55304 Wednesday,June 12,2019 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. Ham Lake,MN 55304 Page 2 Project Report eneral Project Information 1 Project Title: Project Date: Wednesday, June 12, 2019 Client Name: Country Joe Homes Client Address: 783 Summerbrooke Ct Client City: Eagan, MN 55123 Company Name: Air Mechanical Company Representative: Samantha Lykke Company Address: 16411 Aberdeen St NE Company City: Ham Lake, MN 55304 esign_Data Reference City: Minneapolis, Minnesota Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 n/a 30% 72 29.40 Summer: 88 73 50% 50% 74 37 Check Figures _ Total Building Supply CFM: 1,193 CFM Per Square ft.: 0.260 Square ft. of Room Area: 4,582 Square ft. Per Ton: 1,473 Volume (ft3)of Cond. Space: 38,137 [Building Loads — 1 Total Heating Required Including Ventilation Air: 81,724 Btuh 81.724 MBH Total Sensible Gain: 26,879 Btuh 72 % Total Latent Gain: 10,437 Btuh 28 % Total Cooling Required Including Ventilation Air: 37,316 Btuh 3.11 Tons (Based On Sensible + Latent) Notesu R Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:1Users\SlykkelDesktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. Ham Lake.MN 55304 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data _ Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -12.38 100% 30% 72 29.40 Summer: 88 73 50% 50% 74 37.40 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.370 AC/hr 0.190 AC/hr 181 CFM 93 CFM Infiltration Actual: 0.452 AC/hr 0.322 AC/hr Above Grade Volume: X 29,374 Cu.ft. X 29,374 Cu.ft. 13,290 Cu.ft./hr 9,468 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 221 CFM 158 CFM Total Building Ventilation: 95 CFM 95 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 14.94 = (1.10 X 0.970 X 14.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 24.67 = (0.68 X 0.970 X 37.40 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified: 0.370 AC/hr(181 CFM), Construction: Average Summer Infiltration Specified: 0.190 AC/hr(93 CFM), Construction: Average C:\Users\Slykke\Desktop\783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. • Ham Lake,MN 55304 Page 4 Duct Size Preview Room or Source Minimurr Maximum Rough Design SP Duct Duct Htg Clg Act. Duct Duct Name Velocity, Velocity Factor L/10C Loss Velocity Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Lower Level Built-In 450 750 0 0.1 560.2 232 229 3--5 2-Mian Level Built-In 450 750 0 0.1 545.8 396 536 5--6 3-Upper Level Built-In 450 750 0 0.1 544.7 348 428 4--6 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0 0.1 842 976 1,193 12x17 Summary System 1 Heating Flow: 976 Cooling Flow: 1193 C:1Users\Slykke\Desktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. 1111 Ham Lake.MN 55304 Page 5 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure) I General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 1,481.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 1,481.0 sq.ft. Supply Air: 229 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.2 AC/hr Volume: 11,848.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 23 CFM Runout Air: 76 CFM Percent of Supply.: 10 Runout Duct Size: 5 in. Actual Summer Vent.: 18 CFM Runout Air Velocity: 560 ft./min. Percent of Supply: 8 % Runout Air Velocity: 560 ft./min. Actual Winter Infil.: 25 CFM Actual Loss: 0.252 in.wg./100 ft. Actual Summer Infil.: 18 CFM Item Area -U- Htg Sen Clg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain N -Wall-15B0-10sf-8 50 X 8 400 0.050 4.4 1,740 0.0 0 0 E -Wall-15B0-10sf-8 46 X 8 368 0.050 4.4 1,601 0.0 0 0 S -Wall-12F-Obw 50 X 8 293 0.065 5.7 1,657 0.6 0 183 W-Wall-15B0-10sf-8 46 X 8 368 0.050 4.4 1,601 0.0 0 0 S-GIs-4a shgc-0.28 0%S 17.5 0.290 25.2 442 16.8 0 294 S-GIs-4agdoor shgc-0.28 0%S 42 0.290 25.2 1,060 16.8 0 706 S-GIs-4a shgc-0.28 0%S (2) 25 0.290 25.2 630 16.8 0 420 S-GIs-4a shgc-0.28 0%S 22.5 0.290 25.2 568 16.8 0 378 Floor-21A-20 1 X 1481 1481 0.027 2.3 3,479 0.0 0 0 Subtotals for Structure: 12,778 0 1,981 Infil.: Win.: 24.9, Sum.: 17.8 400 5.790 2,316 0.665 438 266 Ductwork: 972 0 AED Excursion: 191 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 900 1,200 Li.ghting;.........._.. 300 1,023 Room Totals: 16,066 1,538 4,891 C:1Users\Slykke\Desktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. le Ham Lake,MN 55304 Page 6 Detailed Room Loads - Room 2 - Mian LeveljAverage Load Procedure) General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 1,481.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 1,481.0 sq.ft. Supply Air: 536 CFM Ceiling Height: 9.0 ft. Supply Air Changes: 2.4 AC/hr Volume: 13,329.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 5 Actual Winter Vent.: 39 CFM Runout Air: 107 CFM Percent of Supply.: 7 ok Runout Duct Size: 6 in. Actual Summer Vent.: 43 CFM Runout Air Velocity: 546 ft./min. Percent of Supply: 8 % Runout Air Velocity: 546 ft./min. Actual Winter Infil.: 108 CFM Actual Loss: 0.185 in.wg./100 ft. Actual Summer Infil.: 77 CFM Item Area -U- Htg Sen CIg Lat Sen Description Quantity Value HTM Loss HTM Gain Gain N -Wall-12F-Obw 50 X 9 380.5 0.065 5.7 2,152 0.6 0 237 E-Wall-12F-0bw 46 X 9 404 0.065 5.7 2,285 0.6 0 252 S-Wall-12F-Obw 50 X 9 286.5 0.065 5.7 1,620 0.6 0 179 W-Wall-12F-Obw 46 X 9 380 0.065 5.7 2,149 0.6 0 237 N -Door-11 G 3 X 7 21 0.540 47.0 987 13.5 0 284 N -Door-11 N 3 X 7 21 0.350 30.5 639 8.8 0 184 N -GIs-4a shgc-0.28 100%S (2) 27.5 0.290 25.2 694 9.4 0 258 S-GIs-4a shgc-0.28 0%S (2) 30 0.290 25.2 756 16.8 0 504 S-GIs-4agdoor shgc-0.28 0%S 21 0.290 25.2 530 16.8 0 353 E-GIs-4a shgc-0.28 0%S 10 0.290 25.2 252 30.2 0 302 S-GIs-4a shgc-0.28 0%S (3) 49.5 0.290 25.2 1,248 16.8 0 831 S-GIs-4a shgc-0.28 0%S (3) 63 0.290 25.2 1,590 16.8 0 1,059 W-GIs-4a shgc-0.28 0%S (2) 8 0.290 25.2 202 30.3 0 242 W-GIs-4a shgc-0.28 0%S 26 0.290 25.2 _ 656 30.2 0 786 Subtotals for Structure: 15,760 0 5,708 Infil.: Win.: 107.8, Sum.: 76.8 1,728 5.790 10,005 0.664 1,894 1,147 Ductwork: 1,659 0 AED Excursion: 447 People: 200 lat/per, 230 sen/per: 1 200 230 Equipment: 1,200 2,200 Lighting: 500 1,705 Room ,705Room Totals: 27,424 3,294 11,437 C:\Users\Slykke\Desktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. 1111 Ham Lake,MN 55304Page 7 Detailed Room Loads - Room 3 -Upper Level (Average Load Procedure) General - Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 1,620.0 ft. System Number: 1 Room Width: 1.0 ft. Zone Number: 1 Area: 1,620.0 sq.ft. Supply Air: 428 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 12,960.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 4 Actual Winter Vent.: 34 CFM Runout Air: 107 CFM Percent of Supply.: 8 % Runout Duct Size: 6 in. Actual Summer Vent.: 34 CFM Runout Air Velocity: 545 ft/min. Percent of Supply: 8 % Runout Air Velocity: 545 ft./min. Actual Winter Infil.: 89 CFM 1 Actual Loss: 0.185 in.wg./100 ft. Actual Summer Infil.: 63 CFM Item Area -U- Htg Sen Clg Lat Sen Description _ Quantity Value HTM Loss HTM Gain Gain N -Wall-12F-Obw 50 X 8 333.8 0.065 5.7 1,887 0.6 0 208 E-Wall-12F-0bw 39 X 8 297 0.065 5.7 1,680 0.6 0 185 S-Wall-12F-Obw 50 X 8 339 0.065 5.7 1,917 0.6 0 212 W-Wall-12F-0bw 39 X 8 312 0.065 5.7 1,764 0.6 0 195 N -GIs-4a shgc-0.28 100%S (4) 60 0.290 25.2 1,512 9.3 0 560 N -GIs-4a shgc-0.28 100%S 6.2 0.290 25.2 158 9.4 0 59 E -GIs-4a shgc-0.28 0%S 15 0.290 25.2 378 30.2 0 453 S-GIs-4a shgc-0.28 0%S (3) 45 0.290 25.2 1,134 16.8 0 756 S-GIs-4a shgc-0.28 0%S 16 0.290 25.2 404 16.8 0 269 UP-Ceil-16B-44 1620 X 1 1620 0.022 1.9 3,101 1.1 0 1,746 Floor-20P-30 1 X 139 139 0.035 3.0 423 0.3 0 44 Subtotals for Structure: 14,358 0 4,687 Infil.: Win.: 88.8, Sum.: 63.3 1,424 5.790 8,245 0.664 1,561 945 Ductwork: 1,455 0 AED Excursion: 357 People: 200 lat/per, 230 sen/per: 4 800 920 Equipment: 900 1,200 Lighting: 300 1,023 Room Totals: 24,058 3,261 9,132 C:1Users\Slykke\Desktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Air Mechanical Inc. • Ham Lake,MN 55304 Page 8 rSystem '1 Room Load Summary Htg Min Run Run CIg CIg Min Act Room Area Sens Htg Duct Duct Sens Lat CIg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Lower Level 1,481 16,066 232 3-5 560 4,891 1,538 229 229 2 Mian Level 1,481 27,424 396 5-6 546 11,437 3,294 536 536 3 Upper Level 1,620 24,058 348 4-6 545 9,132 3,261 428 428 Ventilation 8,821 1,419 2,344 Humidification 51355 System 1 total _ 4,582 81,724 976 26.,879 10,437 1,193 1,193 System 1 Main Trunk Size: 12x17 in. Velocity: 842 ft./min Loss per 100 ft.: 0.100 in.wg toolingSystemSummary _.—41111111111111- __...__ __,,„,i e'`-., - - -_ ensible/Latent Sensible Latent To Tons ; Split Btuh Btuh Btuh. Net Required: 3.11 72% /28% 26,879 10,437 37,316 Equipment -- -- -- --------- -_ ----------- --------------- Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: 0 0 Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:1Users\SlykkelDesktop1783 Summerbrooke Ct.rh9 Wednesday, June 12, 2019, 1:43 PM JIDMCNIIA&ISPAI 711 I /t"V1W'pV inVVeVVentilation, Makeup and Combustion Air EATING,LOOLING a PEUMBING Treeing Custom Comfort"Since 198i Calculations Submittal Form For New 16411 ABERDEEN ST NE,HAM LAKE,MN 55304 Dwellings Site address 783 Summerbrooke Ct Date 6/12/19 Contractor Country Joe Homes Completed By Air Mechanical Section A Ventilation Quantity (Determine quantity by using Table N1104.2 or Equation 11-1) Square feet(Conditioned area including basement— 4582 Total required ventilation 190 finished or unfinished) — _ Number of bedrooms 5 Continuous ventilation 95 Directions -Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. The table and equation are below. Table N1104.2 Total and Continuous Ventilation Rates (in cfm) Number of Bedrooms 1 2 3 4 5 6 - Conditioned space Total/ Total/ Total/ Total/ Total/ Total/ (in sq.ft.) continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 s 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space) + [15 x(number of bedrooms+ 1)]=Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventila-tors (ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation-A minimum of 50 percent of the total ventilation rate, but not less than 40 cfm, shall be provided, on a con-tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. 1 Section B Ventilation Method (Choose either balanced or exhaust) ✓[ alanced,HRV(Heat Recovery Ventilator)or ERV(Energy Eixhaust only(Continuous fan rating in cfm) Recov-ery Ventilator)—cfm of unit in low must not exceed continuous venti-lation rating by more than 100%. Low cfm: 100 High cfm: 200 Continuous fan rating in cfm(capacity must not exceed continuous ventilation rating by more than 100%) Directions -Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typically HRV or ERV's. Enter the low and high cfm amounts. Low cfm air flow must be equal to or greater than the required continuous ventilation rate and less than 100%greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the ventilation fan must not exceed 80 cfm.)Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section C Ventilation Fan Description Location Continuous Intermittent RENEW AIRE EV-200 Mech.Room Directions -The ventilation fan schedule should describe what the fan is for, the location, cfm, and whether it is used for continuous or intermittent ventilation. The fan that is chose for continuous ventilation must be equal to or greater than the low cfm air rating and less than 100%greater than the continuous rate. (For instance, if the low cfm is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow the use of a larger fan that is operated a percentage of each hour. Section D Ventilation Controls Directions-Describe operation and control of the continuous and intermittent ventilation. There should be adequate detail for plan reviewers and inspectors to verify design and installation compliance. Related trades also need adequate detail for placement of controls and proper operation of the building ventilation. If exhaust fans are used for building ventilation,describe the operation and location of any controls, indicators and legends. If an ERV or HRV is to be installed,describe how it will be installed. If it will be connected and interfaced with the air handling equipment,please describe such connections as detailed in the manufactures'installation instructions. If the installation instructions require or recommend the equipment to be interlocked with the air handling equipment for proper operation,such interconnection shall be made and described. RENEW AIRE Honeywell 2 Section E Make-up air 0 Passive (determined from calculations from Table 501.3.1) Powered(determined from calculations from Table 501.3.1) 0 Interlocked with exhaust device(determined from calculation from Table 501.3.1) Other,describe: NOT REQUIRED Location of duct or system ventilation make-up air: Determined from make-up air opening table Cfm Size and type(round,rectangular,flex or rigid) Directions -In order to determine the makeup air, Table 501.3.1 must be filled out(see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re-quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The make-up air supply must be installed per IMC 501.3.2.3. Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherically vent or direct vent assisted appliances and gas or oil appliance or vented gas or oil appliances appliances or no power vent or direct one solid fuel appliance or solid fuel appliances combustion appliances vent appliances Column A Column B Column C Column D 1. 0.15 0.09 0.06 0.03 a)pressure factor(cfm/sf) b)conditioned floor area(sf) 4582 (including unfinished basements) Estimated House Infiltration(cfm): 687 [la x lb] 2.Exhaust Capacity a)continuous exhaust-only N/A ventilation system(cfm);(not applicable to balanced ventilation systems such as HRV) b)clothes dryer(cfm) 135 135 135 135 c)80%of largest exhaust rating(cfm); Kitchen hood typically(not applicable 240 if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) d)80%of next largest exhaust rating (cfm); bath fan typically(not Not applicable if recirculating system or if powered makeup air is electrically Applicable interlocked and matched to exhaust) Total Exhaust Capacity(cfm); 375 [2a+2b+2c+2d] 3.Makeup Air Quantity(cfm) a)total exhaust capacity(from above) 375 b)estimated house infiltration(from 687 above) Makeup Air Quantity(cfm); [3a—3b](if value is negative,no -31 2 makeup air is needed) 4.For makeup Air Opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may be included.) C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. 3 Makeup Air Opening Table for New and Existing Dwelling Table 501.3.2 One or multiple power r One or multiple fan- One atmospherically Multiple atmospherically vent,direct vent assisted appliances and vented gas or oil vented gas or oil Duct appliances,or no power vent or direct appliance or one solid appliances or solid fuel diameter combustion appliances vent appliances fuel appliance appliances Column A Column B Column C Column D Passive opening 1—36 1—22 1—15 1—9 3 Passive opening 37—66 23—41 16—28 10—17 4 Passive opening 67—109 42—66 29—46 18—28 5 Passive opening 110-163 67—100 47—69 29—42 _ 6 Passive opening 164—232 101—143 70—99 43—61 7 Passive opening 233—317 144—195 100—135 62—83 8 Passive opening 318—419 196—258 136—179 84—110 9 w/motorized damper Passive opening 420—539 259—332 180—230 111—142 10 w/motorized damper Passive opening 540—679 333—419 231—290 143—179 11 w/motorized damper Powered makeup air >679 >419 >290 >179 NA Notes: A.An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B.If flexible duct is used,increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C.Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D.Powered makeup air shall be electrically interlocked with the largest exhaust system. Section F Combustion ✓0 Not required per mechanical code(No atmospheric or power vented appliances) 0 Passive(see IFGC Appendix E,Worksheet E-1) Size and type 6"INSULATED FLEX Other,describe: Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Section F calculations follow on the next 2 pages. 4 Directions -The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method. For new construction,4b of step 4 is required to be filled out. IFGC Appendix E,Worksheet E-1--Residential Combustion Air Calculation Method(for Furnace,Boiler,and/or Water Heater in the Same Space) Step 1:Complete vented combustion appliance information. Furnace/Boiler: raft Hood OFan Assisted DDirect Vent Input: Btu/hr or Power Vent Water Heater: raft Hood OFan Assisted DDirect Vent Input: Btu/hr or Power Vent Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances.The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 L x W x H L W H Step 3:Determine Air Changes per Hour(ACH)1 Default ACH values have been incorporated into Table El for use with Method 4b(KAIR Method). If the year of construction or ACH is not known,use method 4a(Standard Method). Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) 4a.Standard Method Total Btu/hr input of all combustion appliances Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required TRV: ft3 Volume(TRV)If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.If CAS Volume(from Step 2)is less than TRV then go to STEP 5. 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hr input of all fan-assisted and power vent appliances Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find RVFA: ft3 Required Volume Fan Assisted(RVFA) Total Btu/hr input of all Natural draft appliances Input: Btu/hr Use Natural draft Appliances column in Table E-1 to find RVNFA: ft3 Required Volume Natural draft appliances(RVNDA) Total Required Volume(TRV)=RVFA+RVNDA TRV= 0 + 0 = 0 TRV ft3 If CAS Volume(from Step 2)is greater than TRV then no outdoor openings are needed.If CAS Volume(from Step 2)is less than TRV then go to STEP 5. Step 5:Calculate the ratio of available interior volume to the total required volume. Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) Ratio=0 /0 =N/A Step 6:Calculate Reduction Factor(RF). RF=1 minus Ratio RF=1 - ° =1 Step 7:Calculate single outdoor opening as if all combustion air is from outside.Total Btu/hr input of all Combustion Appliances in the same CAS Input: 0 Btu/hr(EXCEPT DIRECT VENT) Combustion Air Opening Area(CAOA):Total Btu/hr divided by 3000 Btu/hr per in2 CAOA=0 /3000 Btu/hr per in2=0 _ in2 Step 8:Calculate Minimum CAOA: Minimum CAOA=CAOA multiplied by RF Minimum CAOA=0 x' =0 in2 Step 9:Calculate Combustion Air Opening Diameter(CAOD): CAOD=1.13 multiplied by the square root of Minimum CAOA CAOD=1.13'J Minimum CAOA= in.diameter go up one inch in size if using flex duct 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section G304. 5 IFGC Appendix E,Table E-1 Residential Combustion air(Required Interior Volume Based on Input Rating of Appliance) Input Rating Standard Method Known Air Infiltration Rate(KAIR)Method (cu ft) (Btu/hr) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 _ 375 1,050 525 15,000 750 1,125 563 , 1,575 788 20,000 1,000 1,500 750 2,100 , 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 _3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 _ 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 _ 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 _ 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 _ 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 _ 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 _ 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 _ 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 _ 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 _ 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1. The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code.The default KAIR used in this section of the table is 0.20 ACH. 2. This section of the table is to be used for dwellings constructed prior to 1994.The default KAIR used in this section of the table is 0.40 ACH. 6 EAGAN 7%4 City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Summerbrooke Lot Number 8 Block Number 1 Address 783 Summerbrooke Court Builder Country Joe Homes Phone Number: 952-380-8120 Contact: Steve Sauber Tree Protection Requirements: Tree Protection Fencing Installed on Site(Orange Poly Fence) Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: Not Required X As Follows: Five (5) Category A trees (>=4.0" caliper deciduous trees, or>= 12' conifer trees). Per approved Tree Mitigation Plan, four(4) Black Hills Spruce trees (already installed in the backyard area), and one (1) American Sentry Linden (to be installed following construction). Attachments: EAGAN FORESTRY DIVISION X Yes (Refer to a* 'J4E ` : • ! =tails) No BY Fmk Additional Notes: DATE fr /1 H:lghove12019fileltreepres\Tree Preservation Plan Summerbrooke Lot 8 Sock 1 ADDRESS: 783 SUMMERBROOKE COURT CERTIFICATE OF SURVEY FOR COUNTRY JOE HOMES n T i ,, I L-U I 1 1 X913.0 x912.1 POND 41135X9o< STozM HIM=909.5 70.055 X 910.9 X 910.1 I L_V I 78 ti N1ANr1ot[ �� - - . , . RIM_914.5i N87°39'58"W _ - 1 --V'77---------------,--- __....,__94.,. ~7120 coir nG'e L'i'i'-'- 171.9 NOTE:ALL BUILDING o ;s.q rscr.0' at46 9329 9127 DIMENSIONS ARE SHOWN 70 _ OUTSIDE OF FOUNDATION X916.4 ,t19 915.6 -- 92.9 1110 WO���� 92 91.7 --X9110.7 WALL r. 20. 919.1 3 / SCTBACIC I M[ 924.1 (�) L_/3057161G R[T9 NTNG 5-60 6 •1-923.0 X 922.0 4919.8 X919.5 X 920.5 F- LOT p 1-'- BENCH-MARK 8 FIRE HYDRANT AT END OF C) SUMMERBROOKE CIRCLE, -j I t BLOCK 1 F- TNH ELEV.-915.99 X975.3 ? I X921.0 I C) 921.7 _.1 X 923.9 1 C 924.1 X 924.0 9X3.1 I f f 924.49 f i 924.3 1 y 190 5911.6 I '^ X924.8 q X 926.1 J J •crc19, ���;•{{••}}�� z °c z LOT AREA = 9,887 SQ. FT. E,o i!� '92" s �� 925.) p I O 00 9255 i 6 0 925.0 ISS 925.0 I O.I p O cc T. N T I X 923.3 CD (NI PORCH AREA = Z2300 Q. T. 11050. FT. CNI x p 0o SIDEWALK = 30 SO. FT. T- I o PROPOSED �5 e I c DRIVEWAY= 834 SO. FT. p 2-STORY p X 9263 0 x/70 `926.3 ) IMPERVIOUS = 3,214 SQ. FT. X 931.4 Z x "061,e o I - 32.51 X 4247 X 929.3 f 929.9 1 x 927.1 x927.1 GARAGE 0 O 970.1' ��9253 X9I7A X 931.5 6 031 01 X 930A X K 930.3 ^ 930.3 20,0 930.18 m P0 n i 0.'00 0� I 930.4 0.0 �J = �-1 934,4 . 4l'YIF, 925.3 9311 i11,X1 9303 '1.6 I PROPOSED DRIVEWAY I I X 933.0 93,.51 5.7% + r I x 933.0 1 j X 931.9 X9313 1)929'8 X 929.2 - - - - - J ' ( UTILITY 130X[5 930.5® ®930.2 O 937.2 awe C3 - . - . 69221 �93I.0 `� --2?.0-931.3'' 70�9oV9 9929729 7 x929-1 . X932.1 _.931.0 _ -_--22•:----, N89° '40'YY 11929.2 x925.7 9317 931.1 CONCRCTI.C7R6 4 Go307 4 N N C1 SUMMERBROOKE COURT _ _ 1"=20' tir1:;E g ® DENOTES MAILBOX SETBACKS O DENOTES IRON PIPE MONUMENT SET FRONT-30' • DENOTES FOUND IRON PIPE MONUMENT SIDE-ALONG RIGHT OF WAY= 30'SIDE INTERIOR = 10'ON R-1 (R-1 is DENOTES PROPOSED DRAINAGE DIRECTION lots over 12,000 sf) SIDE INTERIOR ON R 1-S = 6' et DENOTES SERVICE LOCATION SIDE ON GARAGE = 5' In DENOTES WOOD HUB • REAR = 15' PROPOSED TOP OF WALL ELEV. = 933.7 000.0 DENOTES EXISTING ELEVATION NOTE ANY LMNG SPACE!S CONSIDERED PROPOSED GARAGE FLOOR ELEV- = 933.4 THE HOUSE SETBACK, NOT THE GARAGE PROPOSED FLOOR ELEV.. = 915.7 ® DENOTES PROPOSED ELEVATION SETBACK '-..~1'0Yr- DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION DENOTES DECIDUOUS TREE LOT 8,BLOCK 1,SUMMERBROOKE,CITY OF FAGAN,DAKOTA COUNTY.MINNESOTA. DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED Surveying&Associates LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage Avenue 1082 C18T Road E. DENOTES CONCRETE SURFACE Notaddd,MN 55067 ElnivO1a,MN 56331 DATE: 6-213-2019 Flamm: B A Plton..(962)895-9212 THOMAS J.O'MEARA,LAND SURVEYOR tommvaeboNensuiveylna.m' F=.11162158643268 MINNESOTA LICENSE NO.46167 DENOTES GRAVEL SURFACE S:\Projec s\Eagan\summecbrookc\dwg\lot8b181-CERT.dwg 6/28/2019 7:21:35 AM CST ( i - \., , -----„,.77. - T-iiivof...---\- \.. ‘ \ \.‘ \ ., \ •,., .st‘_b,--i-- .-- '''' 41* '\ ____ - - - --- .-1--,"*.--"/./ . „.„,--- \ \ \ \Z . , V . . ... �' \ -- %, --. (.. ... _.... _. o, cl2�, , 1 ' .� 7 \.\ \ ,>: ' 1 \ ,\.: , . \\., -i-4 / 1 --mid \‘•...evoir4.7*--. ...,,._ AT,- I 1 sir r►�s AM�� _...:„.„4..."!" \ � ,*.-,-,w,, F_ „.‘. ---111• ,_,.v.\ . ..,. -\ 1 S----------/ ci0i_i;i -; 7 '- _- :_\c--.,03\ . &----- L_v•.gI *-A,)lt.ic_i, --g 0 8 iyiilli -7. - -N•• WL '-[*�'�.3 ni 7. !t ,\ i - i S •.....+k\ \ —y ' .i\. MI l�� ' { i ( .11....1111............"-- u, eifii I .0. - P' af * * ac 2),,,„„;:,,,.‘ • *AM (3-) - Air' i ,1 rie —A �, .„-,.) , _ ..__, . _ ---.-7*--' • - . 1 / . . ' 1111117-r -IPIIIMIA0111111. ;,4Edi-Al.L '-"--0411w----, —'1__ ,,,...M1 ..-- - ,......-46,7- -- -Argil ' __tel tAile!A S ; - ..P.'l *: .- :1".1:'•- •'' •1-=-7----:-,-';---71----'-' 411111,JAW viti..71"."',''••••....j.:t....."--. • IPTIPOir fik )i. 4IV. ,, ......,, .,.. .."1",. ...0,41„-,44:-.41;.c.A.)7,-;. ,. ____,: \:,7 ._____ • 11111h, r V , . .. , , „........„„ , ,...,_ (' z . Ramo ,...„,, , q ., . Ey mummi / \ ir mow ,8 .Z.------:,_ ' _______ -.....___ / i) 1 / 77- ___:1 ......, N \ -0 ,,,, -- - ---. - .......„, ,.„ ,-- / i , 1 „it.-I ,\ . I.,. f -.,_.� \ , .440 „s„.1_ MAI% I - - \ i i 01 . ,.,a: it.\, * 4 ......L. dioi; 1 4.1110:411kaht' ,,,i&a,',N,.,.. iiiiit ; -____. -._ - ?ilk, --N inali ''' Ali Ark,11.11111/1 mg iir . is Ff'111141.11. IL - litii,- ,i,”" >/•______,..... .._----__ -..Nigainimpi .., - 1.• ______,„___ > _,\ ,\\ \ .\ \ s ,SUMMERBROOKE 6 .. , , - *. -,ma_i----c . 9.3p • ilk ---- WINIWit....1.1•11111_ 11.W.02.''2111 IN 1111MLIIIIIIIMIret4111111WPAN'tilliffilliS11 i • .\ V,I1 V.*- .r -"" . ' <,,, 1. 1Wi4 • ,/ ,ik v i c.., .0 ,ik‘.-. \ wit ) ' . lriPtt' -' ". \ Viir- . \/, / 't 940 .. \2 \. L ' \ • 2 ` ,23 14 --- \ 1 26 / I; l '• / ) . \ lii .1/112i. - . 1 ., '75:40 , , : -76L .,,,, \( j \ ,,, i, \ \ ( ( Ii r,., . \\ \ •' ' \ \ , . ....._._;u , ..._ _. 1 ,: • ' \ 10-- - -( I / L-i,:..,‘. ,-' \, . _ - ---1 \ IL ' \k9 \ i- '- • , , _____ ' _.---,_--,_.,.:i.-._,_.___,-___! \,,...:-..„,-..-_____,.-,i.,..„-7X X_', = _...._X—93:' • ', L 7;.A-1,:„.w-__,,.,_:_--Tlg ♦ sy.[�•"'r err' ���� ? k� �� �� ..1.....- S NiS _ '.. f ` \ - � -. _ - _\ ` �- ` �` � � - - � � _- ' � Y � 06-S- LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION PROPERTY LEGAL: Lot 8, Block 1, Summerbrooke DATE OF SURVEY: 6-28-19 LATEST REVISION: a) a) c as C.) O z Q DOCUMENT STANDARDS O 0 0 • Registered Land Surveyor signature and company O ❑ 0 • Building Permit Applicant O 0 0 • Legal description 0 0 ❑ • Address O 0 0 • North arrow and scale O 0 0 • House type(rambler,walkout, split w/o,split entry, lookout, etc.) O 0 0 • Directional drainage arrows with slope/gradient% 0 0 ❑ • Proposed/existing sewer and water services&invert elevation 0 0 0 • Street name O ❑ 0 • Driveway(grade&width-in RNV and back of curb,22'max.) 0 0 0 • Lot Square Footage O 0 0 • Lot Coverage ELEVATIONS Existing O 0 0 • Property corners O 0 0 • Top of curb at the driveway and property line extensions ❑ 0 0 • Elevations of any existing adjacent homes 0 0 0 • Adequate footing depth of structures due to adjacent utility trenches 0 0 0 • Waterways(pond, stream,etc.) Proposed 0 0 0 • Garage floor O ❑ 0 • Basement floor O 0 0 • Lowest exposed elevation (walkout/window) O 0 0 • Property corners ❑ • Front and rear of home at the foundation Y N • PRV Required PONDING AREA(if applicable) O 0 0 • Easement line O ❑ ❑ • NWL 0 ❑ ❑ • HWL ❑ 0 0 • Pond#designation ❑ 0 0 • Emergency Overflow Elevation ❑ 0 • Pond/Wetland buffer delineation Y • Shoreland Zoning Overlay District Y • Conservation Easements DIMENSIONS O 0 0 • Lot lines/Bearings&dimensions O 0 ❑ • Right-of-way and street width(to back of curb) O 0 0 • Proposed home dimensions including any proposed decks,overhangs greater than 2',porches,etc. (i.e. all structures requiring permanent footings) O 0 0 • Show all easements of record and any City utilities within those easements 0 ❑ 0 • Setbacks of proposed structure and sideyard setback of adjacent existing structures 0 ❑ 0 • Retaining wall requirements: Reviewed By: Dave Westermayer Date 7/22/19 G:/1 Engineering/Forms/Cert.of Survey Checklist Fillable 6-28-19 ADDRESS: 783 SUMMERBROOKE COURT /5-‘e6 - CERTIFICATE OF SURVEY FOR 3:1 Ma ' Slopes COUNTRY JOEHOMES or Be A ETER COt4TROL ERS PAX I r1-r I 1 L_\J I I 1 X913.0 X912.1 POND 11.6 46411 X910.1 I ^T x 905 STORM HWL=909.5 70.05 X 910.9 L_\J MANHOLE • -- RIM=914.51 N87°39'58"W .. . - 912.6 1, y 2.0 914s NOTE ALL BUILDING O ` DRAINAGE UT�417'--_- 72.9 9127 f12.9 DIMENSIONS ARE SHOWN TO rfi , 414.6 O OUTSIDE OF FOUNDATION X 916.4 921.9 /r 915.6 WALL X���� 921.9 ��- I _ X 914.2 921.9 1•-•�ow40imam..`_ ' OR"-- - : 914 7 X 918.7 921.2 920.0 919.4 5 SETBACK UNE 924.1 ' ' 5 ��t �3) ';� i t----EXISTING RETAINING WALL X 919.5 jG �� �`�_"-923.0 X922.0 0919.8 X 920.8 1 ``� BENCH-MARK E. - LOT O I FIRE HYDRANT AT END OF . SUMMERBROOKE CIRCLE, -J I BLOCK 1 - TNH ELEV.=915.99 X 925.3 f I C 923. f 1 X 924.0 -J IX 923.9 1 : 924.1 X 924.0 925.1 I fx 924.4 , , r, X 924.3 X 14.0 O K 924.6f . f , 924.8 Ti X 926.1 W f`;',1 q 92 ; LOT AREA = 9,887 SQ. FT. E 1 I - 00 51 18.0 X 925.0 X 925.0 18.0 925.0 -_ -- 92S.3 O10.00 Q O HOUSE AREA = 2,230 SQ. FT. CO (V T, 1 X 925.3 1 I Q N PORCH AREA = 120 SQ. FT. 00 i i p CO SIDEWALK = 30 SQ. FT. CV o o PROPOSED 925 8 '� o DRIVEWAY = 834 SQ. FT. Q I N 2-STORY !1 r' p X 926.5 FB/WO t CD 926.3 'O IMPERVIOUS = 3,214 SQ. FT. X 931.4 Z X 930.61 X O ` f ( J = 32.51 X 929.8 X 929.5 CO X X 927.1 X 927.1 1 929.9 GARAGE cl.o O G 1 930.1`�i- X 927.4 ��C 928.3 X 931.8 931.01 N X 930.4 930.3 930.3 20.0 930.1x iI v '1 q • ^ Ni ,\, Lo PORCH • - f pq i � 130.3 9304 2000930.4 -928.8 9315 4 I •QO PROPOSED I o DRIVEWAY X 933.05.7% i i X 933.0 `932.51 1 i X 931.9 1 i) 929.8 L X931.5 5 X929.2 J UTILITY _ _ _ BOXES 930.51-1 N930.2 O O �� 932.2 CURB - X 932.4 -- 22.0---�� 931.0 STOP 929.7 929.1 • •X 932.0 "931.5id5ó 929.7 )(932.1 )1)131.8 --- 22.0 -- N89°41'40'1/1/ )(929.2 )(928.7 931.7 931.1 CONCRETE CURB$GUTTER 930:2 N to N N SUMMERBROOKE COURT „ _- , 1 20 CENTERLINE rrhr I . EWED ® SETBACKS DENOTES MAILBOX By A �,A-� O DENOTES IRON PIPE MONUMENT SET FRONT-30' Date MIA • DENOTES FOUND IRON PIPE MONUMENT SIDE-ALONG RIGHT OF WAY = 30' SIDE INTERIOR = 10' ON R-1 (R-1 is E AGAN ENGINEERING DEPT. DENOTES PROPOSED DRAINAGE DIRECTION lots over 12,000 sf) SIDE INTERIOR ON R1-S = 6' 0 DENOTES SERVICE LOCATION SIDE ON GARAGE = 5' O DENOTES WOOD HUB REAR = 15' PROPOSED TOP OF WALL ELEV. = 933.7 000.0 DENOTES EXISTING ELEVATION NOTE: ANY LIVING SPACE IS CONSIDERED PROPOSED GARAGE FLOOR ELEV. = 933.4 THE HOUSE SETBACK, NOT THE GARAGE PROPOSED BASEMENT FLOOR ELEV. = 925.7 (000.0) DENOTES PROPOSED ELEVATION SETBACK ,'+'Ooa DENOTES EXISTING CONTOUR PROPERTY DESCRIPTION 0" DENOTES DECIDUOUS TREE LOT 8,BLOCK 1,SUMMERBROOKE,CITY OF EAGAN,DAKOTA COUNTY,MINNESOTA. V': DENOTES EVERGREEN TREE Bohlen I HEREBY CERTIFY THAT THIS SURVEY WAS PREPARED BY ME OR DENOTES BITUMINOUS SURFACE Surveying & Associates UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. 31432 Foliage Avenue 1682 Cliff Road E. DENOTES CONCRETE SURFACE Northfield,MN 55057 Burnsville,MN 55337 �"r� nM R DATE: 6-28-2019 Thaw num.m. Phone:(507)645-7768 Phone:(952)895-9212 THOMAS J.O'MEARA,LAND SURVEYOR tomeara@bohlensurveying.com Fax:(952)895-9259 DENOTES GRAVEL SURFACE MINNESOTA LICENSE NO.46167 S:\Projects\Eagan\summerbrooke\dwg\lot8blkl-CERT.dwg 6/28/2019 7:21:35 AM CST 3/13/2020 C3maiI-FW:Pan inspection To:"jtrebil@countryjoehomes.com"<jtrebil@countryjoehomes.com> , Subject:Pan inspection +, To whom It may concern: • The way we install custom shower pans is that we slope a pre-pan of tile crate pitched toward drain.Next we Install a waterproof pvc membrane on top of the sloped crete that Is folded upright in the corners and comes to the top,in the center of the mud curb.The membrane runs roughly 6-10"up the studs behind the Durock cement board.The membrane is also mechanically adhered to the collar of the three piece shower drain.The the final portion of the tile crete Is applied sloped at minimum 114"per foot towards drain.After that cures,we add one more layer of protection by rolling on a topical waterproofing.We use Ardex 8+8,an acrylic based liquid compound and a Portland and other hydraulic cement based powder.This waterproofing is roiled on the shower pan,curb,and up the durock 2-3 ft.Our showers have 2 waterproofing systems to prevent any leaks.We stand by our work with a full warranty.Thanks for your time. Eric Ceramic tile manager VA, Focal Point Flooring car 50p( filam- . Ct Lpf (91• httue://maiL000de arnImsile ........w.td..u..... .1 MIA wwww+ .....�.........�... . • _.. RECEIVED JUL 2 9 MO • 4 rti* I #. .• 4- ti Tr The Insulation and WateroofingProfessionals completed the work assigned to me on August 21st, 2019 at address 783 Summerbrooke Ct jr 8.61- I sprayed just under 41 gallons of our GMX tar waterproofing. x 0 14, /7___:Zat/Itotr:e.) 21025 Edmonton Avenue • Farmington, MN • 55024 Phone: 651.463.9333 • Fax: 651.463.9339 • www.installbuild.com I' , 14, I •; • 4: f•• 4 t t. e 4/44 ttim REC. JVED JUL 292020 The Insulation and Waterproofing Professionals n .A //yet. ��if k1 P jCJ/ I completed the work assigned to me on August 21st, 2019 at address 783 Summerbrooke Ct. P,U J1T .tZt /.9G ' I 75h4 •1 r` completed the work assigned to me on August 21st, 2019 at address 783 Summerbrooke Ct I Lid'k L4llco'"pleted the work assigned to me on August 21st, 2019 at address 783 Summerbrooke Ct. We installed foundation insulation, 3" board on the sides with elevation change and 2" board on the front and back of home. Emil poly over all of the foundation insulation from top to bottom. Then we installed exterior and interior drain tile, both connected to sump basket we installed. Rock and fabric also installed with drain tile to meet code. X iff4,41/4, 21025 Edmonton Avenue • Farmington, MN • 55024 Phone: 651.463.9333 • Fax: 651.463.9339 • www.installbuid.com