Loading...
3797 Lakeside Ct-,.INIW L /�2 - 11, istp.Cic( ' pL /6 a.270 - /00 b 0 2020 _/62271 - /ov •0 0 G AN 3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810 (651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694 bu ildinoinspectionsCa.cityofeagan.com �b-W/67 72 2020 RESIDENTIAL BUILDING PERMIT APPLICATION Date: 3/16/2020 Site Address: 3797 Lakeside Court Unit #: I E� For Office Use f i4 6 Permit #: J 6 �� , 6 i Permit Fee:, 1/ 3S 6f eii Date Received: Staff: Resident/ Owner Name: Norton Homes, LLC Phone: 763-559-2991 18215 45th Ave N Ste D Plymouth MN 55446 Address / City / Zip: �!� Applicant is: Owner Contractor / - e - 1 (,, �p .c, (,tx b �`` '' Type of Work Description of work: New Residential 2 story �f Construction Cost: 475'000 Multi -Family Building: (Yes / No ✓ ) Contractor Company: Norton Homes, LLC Contact: Patrick Hiller Address: 18215 45th Ave N Ste D City: Plymouth State: MN Zip: 55446 Phone: 763-559-2991 Email: path@nortonhomes.com License #: BC639221 Lead Certificate #: If the project is exempt from lead certification, please explain why: �``� /` In the last 12 months, Yes i✓ No COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING has the City of Eagan Issued a permit for a similar plan based on a master plan? If yes, date and address of master plan: Licensed Plumber: Mechanical Contractor: Sewer & Water Contractor: Fire Suppression Contractor. Mike's Custom Mechanical Phone: 763-568-7148 Mike's Custom Mechanical Phone: 763-568-7148 DSM Excavating Company Inc Phone: 651-480-1355 Phone: NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the Information may be classified as non public if you provide specific reasons that would permit the City to conclude that they are trade secrets. You may subscribe to receive an electronic notiticatlon from the City of proposed ordinances by signing up for an email update on the Clty's webslte at www.cityofeagan.comisubscribe. Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180 days of permit Issuance. CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you intend to dig to receive locates of underground utilities. www.gopherstateonecaliorg I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Eagan; that I understand this is not a permit, but only an application for a permit, and work is not without a permit; that the work will be in accordan th the approved plan in t ca e of work which requires a review and approval of pla (c(C Applica is PrytedNe, ,�'r x Applicant' Sig 3 -7ti-7 LFlk;dE C�. 6sr' DO NOT WRITE BELOW THIS LINE SUB TYPES Foundation Fireplace Garage Deck Lower Level ' Single Family Multi 01 of _ Plex WORK TYPES New Addition Alteration Porch (3-Season) Exterior Alteration (Single Family) Porch (4-Season) Exterior Alteration (Multi) _ Porch (Screen/Gazebo/Pergola) _ Miscellaneous Pool Accessory Building Interior Improvement Move Building Fire Repair Replace _ Repair Retaining Wall DESCRIPTION Valuation yy7 Ogg Plan Review (25%_ 100% 14 Census Code /o/ #of Units / # of Buildings Type of Construction REQUIRED INSPECTIONS Footings (New Building) Occupancy Code Edition Zoning Stories Square Feet Length Width Footings (Deck) Footings (Addition) Foundation , Foundation Before Backfill Roof: bt Ice & Water Y Final Framing 30 Minutes Fireplace: Rough In Insulation Sheathing Sheetrock Fire Walls Braced Walls Shower Pan 1 Hour it Test Final Reviewed By: RESIDENTIAL FEES Base Fee Surcharge Plan Review MCES SAC City SAC Utility Connection Charge S&W Permit & Surcharge Treatment Plant Radio Meter Read Copies TOTAL Siding Reroof Windows Egress Window _ Demolish Building* Demolish interior Demolish Foundation Water Damage *Demolition of entire building — give PCA handout to applicant TA/f✓ i / MCES System /5- SAC Units g. / s City Water Booster Pump 2.330 PRV ✓f' 1? Fire Suppression Required 60 y0 NO Meter Size: Final / C.O. Required Final / No C.O. Required HVAC _ Service Test Gas Line Air Test _ Hood Pool: _Footings _Air/Gas Tests _Final Drain Tile Siding: Stucco Lath tone Lath _Brick _ EFIS Windows Retaining Wall: _ Footings _ Backfill _ Final Radon Control Fire Suppression: _Rough In _Final t* Erosion Control Other: nr , Building Inspector cjgp,4 //.i 9 tzQ 9*S / Et PQ2 / 3?8' 2 9 :Ldi Aft. l- /6 V @ q5 - Gam- ?37 '0 6'o4i 3 940 OP /00 079 /7 / 3/ `j/( 44' 33 r 3 Goto 616 Page 2 of 3 Peggy Fleck /i.2ie From: Pam Dudziak Sent: Wednesday, July 08, 2020 12:17 PM To: Peggy Fleck Subject: RE: 3797 Lakeside Ct - L2, B1 Lakeside of Eagan Yes, you can remove this hold. I reviewed the survey and it satisfies the applicable R-1S zoning standards. Pam Dudziak Planner 3830 Pilot Knob Rd I Eagan, MN 55122 Office: 651-675-5691 https://www.cityofeagan.com Original Message From: Peggy Fleck <pfleck@cityofeagan.com> Sent: Tuesday, July 7, 2020 9:12 AM To: Pam Dudziak <pdudziak@cityofeagan.com> Subject: 3797 Lakeside Ct - L2, B1 Lakeside of Eagan Pam, Jeff brought this permit app up for me to process. There is a pop up that says not to process until you have given your approval on the site survey. It is okay to process and can I remove the hold? Thanks, Peg Peggy Fleck Clerical - Community Development 3830 Pilot Knob Rd I Eagan, MN 55122 Office: 651-675-5674 https://www.cityofeagan.com 1 New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or In the electrical distribution panel. Date Certificate Post' IS V IJCV 6/15/2020 Mailing Address of the Dwelling or Dwelling Unit 3797 Lakeside ct City Eagan NORTON I HOMES Name of Residential Contractor Norton Homes, LLC MN License Number BC639221 /‘ .P6'0/ THERMAL ENVELOPE RADON CONTROL SYSTEM Insulation Location Type: Check All That Apply Passive (No Fan) Non or Not Applicable 0 m i m 5 rn ti Foam, Closed Cell Foam Open Cell Mineral Fiberboard Rigid, Extruded Polystyrene : Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here Below Entire Slab Foundation Wall R-10 Perimeter of Slab on Grade Rim Joist (1st Floor) R-20 Rim Joist (2nd Floor+) R-20 Wall R-20 Ceiling, flat R-49 Ceiling, vaulted R-49 Bay Windows or cantilevered areas R-20 Floors over unconditioned area R-30 Describe other insulated areas Building envelope air tightness: Duct system air tightness: Windows & Doors Average U-Factor (excludes skylights and one door) U: 0.22 Heating or Cooling Ducts Outside Conditioned Spaces Not applicable, all ducts located in conditioned space Solar Heat Gain Coefficient (SHGC): 0.28 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Not required per mech. code Fuel Type Natural gas Electric Electric Passive Manufacturer Amana Rheem Amana Powered Model Rating or Size ACS92100 Input In BTUS: 100k 2 -50 gallon electric Capacity In Gallons: 100 ASX13036 Output In Tons: 3 Interlocked with exhaust device. Describe: Other, describe: Efficiency AFUE or HSPF% 92% SEER /EER 13 Residential Load Calculatit Heating Loss Heating Gain Cooling Load Location of duct or system: 80193 26708 31739 Cfm's " round duct OR MECHANICAL VENTILATION SYSTEM metal duct Describe any additional or combined heating or cooling systems if installed: (e.g. two fumaces or air source heat pump with gas back-up fumace): Select Type Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Low. Low. 90 High: High: 200 Combustion Air Select a Type Not required per mech. code Balanced Ventilation capacity in cfms: Passive Other, describe: Location of duct or system: Location of fan(s), describe: lbath fans(4-80 2-50), kitchen (300), hry (200 Capacity continuous ventilation rate in cfms: 90 Cfm's round duct OR Total ventilation (Intermittent + continuous) rate in cfms: 920 " metal duct /6 .� REVISED 6/15/2020 3797 Lakeside Ct, Eagan HVAC Load Calculations for Norton Homes Plymouth, Mn RHVAc HVAC Ls Prepared By: Amanda Fisher Mikes Custom Mechanical, Inc Po Box 171 Champlin, Mn 55316 763-568-7148 Thursday, June 11, 2020 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Mike's Custom Mechanical, Inc . % 3797 Lakeside Ct, Eagan Dayton. MN 55327 Page 2 Project Report General Project Information Project Title: 3797 Lakeside Ct, Eagan Designed By: Amanda Fisher Project Date: Monday, March 9, 2020 Client Name: Norton Homes Client City: Plymouth, Mn Company Name: Mikes Custom Mechanical, Inc Company Representative: Amanda Fisher Company Address: Po Box 171 Company City: Champlin, Mn 55316 Company Phone: 763-568-7148 Company E-Mail Address: info@mikescustommechanical.com Company Website: www.mikescustommechanical.com Design Data Reference City: Minneapolis/St. Paul AP, Minnesota Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 44 Degrees Elevation: 834 ft. Altitude Factor: 0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb ReLdum ReI.Hum Dry Bulb Difference Winter: -15 -15 n/a 30% 70 31.02 Summer: 88 71 44% 50% 75 24 Check Figures Total Building Supply CFM: 1,147 CFM Per Square ft.: 0.180 Square ft. of Room Area: 4488 sq ft -6Teee" Square ft. Per Ton: 2,412 Volume (ft3): 48,666 Building Loads Total Heating Required Including Ventilation Air: 180.193 Btuh 80.193 MBH Total Sensible Gain: 26,708 Btuh 84 % Total Latent Gain: 5,031 Btuh 16 % Total Cooling Required Including Ventilation Air. 31,739 Btuh 2.64 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\3797 Lakeside Ct, Eagan.rh9 Thursday, June 11, 2020, 6:21 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Mike's Custom Mechanical, Inc 3797 Lakeside Ct, Eagan Dayton. MN 55327 Pd Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -15 -15 100% 30% 70 31.02 Summer: 88 71 44% 50% 75 23.51 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor. 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.280 AC/hr 0.150 AC/hr 227 CFM 122 CFM Infiltration Actual: 0.199 AC/hr 0.000 AC/hr Above Grade Volume: X 48,666 Cu.ft. X 48,666 Cu.ft. 9,671 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 161 CFM 0 CFM Total Building Ventilation: 160 CFM 160 CFM —System 1— Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 90.72 = (1.10 X 0.970 X 85.00 Winter Temp. Difference) Winter Infiltration Specified: 0.280 AC/hr (227 CFM), Construction: Average Summer Infiltration Specified: 0.150 AC/hr (122 CFM), Construction: Average C:\ ...\3797 Lakeside Ct, Eagan.rh9 Thursday, June 11, 2020, 6:21 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Mike's Custom Mechanical, Inc l 3797 Lakeside et, Eagan Dayton. MN 55327 9 Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain custom glass: Glazing -custom home SHGC 0.28 custom glass: Glazing -custom home SHGC 0.27 custom glass: Glazing -custom home SHGC 0.25 custom glass: Glazing -custom home SHGC 0.27 custom glass: Glazing -custom home SHGC 0.28 custom glass: Glazing -custom home SHGC 0.29 custom glass: Glazing -custom home SHGC 0.3 11 P: Door -Metal - Polyurethan: norton walls: Wall -Frame, Custom, cavity no board insluation siding norton basement2: Wall -Basement, brink stone or concrete wall, floor in 2x6 cavity, core, no interior finish, wood studs, b-49: Roof/Ceiling-Under Attic with Floor (also use for Knee Walls Ceilings), Custom, roof/ceiling-under insulation on attic floor, vented barrier, dark asphault shingles glass, glass, glass, glass, glass, glass, glass, - = - R-20 i u-value 0.22, 277 5,184 0 5,073 5,073 u-value 0.23, 42 821 0 340 340 u-value 0.21, 42 750 0 314 314 u-value 0.22, 25 468 0 199 199 u-value 0.2, 163 2,772 0 2,499 2,499 u-value 0.22, 185 3,460 0 3,182 3,182 u-value 0.22, 25 468 0 214 214 21 518 0 146 146 sulation in 2x6 4312.5 23,828 0 3,728 3,728 wood studs eight inches 1170 6,862 0 695 695 finish Custom, framing board insulation, 2' floor depth Insulation and Partition attic, no or dark sulation slab, any insulation withrrnblill to plus on Attic 1844.8 3,137 0 1,770 1,770 attic with radiant metal, tar and thickness, 2 1558.2 3,577 0 0 0 below floor, gravel or membrane, r 9 i 21A-20: Floor -Basement, oncrete or more feet below grade, no any floor cover, shortest side of floorslab is20' wide __.._..._. Subtotals for structure: 51,845 0 18,160 18,160 People: 6 1,200 1,380 2,580 Equipment: 1,349 4,948 6,297 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 161, Summer CFM: 0 14,621 0 0 0 Ventilation: Winter CFM: 160, Summer CFM: 160 5,806 2,482 2,220 4,702 Humidification Minter) 21.60 gal/day ;.... 7,922 0. 0...... 0.... Total Building Load Totals: 80,193 5,031 26,708 31,739 Check Figures Total Building Supply CFM: 1,147 CFM Per Square ft.: 0.180 Square ft. of Room Area: 4488 sq ft Square ft. Per Ton: 2,412 Volume (ft3): 48,666 Building Loads Total Heating Required Including Ventilation Air. 80,193 Btuh 80.193 MBH Total Sensible Gain: 26,708 Btuh 84 % Total Latent Gain: 5,031 Btuh 16 % Total Cooling Required Including Ventilation Air. 31,739 Btuh 2.64 Tons (Based On Sensible + Latent) Notes �. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\3797 Lakeside Ct, Eagan.rh9 Thursday, June 11, 2020, 6:21 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Mike's Custom Mechanical, Inc IC 3797 Lakeside Ct, Eagan Dayton, MN 55327 Page 34 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM -Zone 1- 1 Family Room 300 5,416 81 1-4 483 899 200 42 42 2 Gasmes And . 420 3,668 55 1-4 283 528 200 25 25 Stairwell 3 Bed 5 195 3,201 48 1-4 226 421 0 20 20 4 Basement Bath 105 787 12 1-4 21 39 0 2 2 5 Mech Room 195 3,572 54 1-4 112 208 0 10 10 6 Exercise 168 2,463 37 1-4 81 151 0 7 7 Zone 1 subtotal 1,383 19,107 286 2,246 400 105 105 -Zone 2- 7 Pantry 41 1,101 16 1-4 96 179 0 8 8 8 Mud Room 94 2,033 30 1-4 220 409 0 19 19 9 Kitchen 231 2,243 34 3-5 589 5,147 1,549 241 241 10 Main Stairwell 206 4,379 66 1-6 471 1,974 0 92 92 11 Greatroom 322 4,316 65 1-6 541 2,267 400 106 106 12 Study 155 2,447 37 1-5 596 1,735 0 81 81 13 Powder Bath 88 577 9 1-4 131 244 0 11 11 14 Dining 155 2,368 35 1-6 467 1,957 200 92 92 15 Ent!), 101 748 11 1-4 326 608 0 28 28 Zone 2 subtotal 1,394 20,212 303 14,520 2,149 680 680 -Zone 3- 16 Bedroom 2 169 2,831 42 1-4 479 893 0 42 42 17 Jack N Jill Bath 195 1,564 23 1-4 217 404 0 19 19 18 Bedroom 3 156 2,816 42 1-5 615 1,791 0 84 84 19 Bedroom 4 192 2,225 33 1-5 595 1,733 0 81 81 20 Master Bath And 272 3,895 58 1-5 581 1,692 0 79 79 Closet 21 3/4 Bath 2nd Floor 96 179 3 1-4 54 101 0 5 5 22 Laundry Room 119 242 4 1-4 330 615 0 29 29 23 Owners Suite 288 3,889 58 1-4 641 1,194 0 56 56 24 Loft And Stairwell 224 5,640 84 2-5 629 3,662 0 172 172 Zone 3 subtotal 1,711 23,281 349 12,085 0 566 566 Zono 1 25 Rim Joist 900 1,884 28 1-4 112 208 0 10 10 Basement To Main 26 Rim Joist Main To 992 1,982 30 1-4 117 218 0 10 10 Second Zone 4 subtotal 1,892 3 866 58 426 0 20 20 Ventilation 5,80 subtract from floor area 2,220 2,482 Humidification 7,_922 System 1 total 6,380 80E193 996 26,708 5,031 1,147 1,147 System 1 Main Trunk Size: 12x17 in. Velocity: 810 ft./min Loss per 100 ft.: 0.092 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load Procedure + Excursion" method. Cooling System Summary , Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.64 84% / 16% 26,708 5,031 31,739 C:\ ...\3797 Lakeside Ct, Eagan.rh9 Thursday, June 11, 2020, 6:21 AM • r Rhvac - Residential & Light Commercial HVAC Loads Mike's Custom Mechanical, IncIli) Dayton. MN 55327 Elite Software Development, Inc. 3797 Lakeside Ct, Eagan Page 35 System 1 Room Load Summary (cont'd) Cooling Sensible/Latent Tons Split Sensible Btuh Latent Total Btuh Btuh Equipment Data Heating System Type: Natural Gas Furnace Model: Indoor Model: Brand: Efficiency: 0 AFUE Sound: 0 Capacity: 0 Btuh Sensible Capacity: n/a Latent Capacity: n/a Cooling System Standard Air Conditioner 0 SEER 0 0 Btuh 0 Btuh 0 Btuh C:\ ...\3797 Lakeside Ct, Eagan.rh9 Thursday, June 11, 2020, 6:21 AM Ventilation, Makeup and Combustion Air Calculations • Submittal Form For New Dwellings Site arkbess Contractor 3-7/1 &Ac i&L04_,Skrti fie cilatue4rryeted c . 1 Ventilation Quantity (Determine quantity by using Table N1109.2 or Equation 11-1) Square feet (Candi area tnduding aaavmaet—finished o unfinished) L42.1 Total required' ve„taatmn �'30 r Number of bedrooms 3 Conffma uaverRflation (/� Directions -Determine the total and continuous ventilation rate by either using Table N1104.2 orequodon 111. The table and equaton are below. Table N11.04 2 ' Total and Continuous Ventilation Rates tm dm) • Number of Bedrooms . 1 2 • 3 4 '5 6 Cpnd)tioned.space in sq. ft.) Total/. . continuous Total/ continuous Total/ continuous Total/ continuous Total/ ' continuous Total/ continuous 1000-1500 -60/40 75/40 90/45 105/53 120/60 135/68 1501-20 0 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/$_3 . 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 ' 130/65 ' 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 . 185/93. 4001-4500 120/60 .135/68 150/75 _ 165/83-- - 180/90 195/98 4501-5000 • 130/65 145/73 160/80 175/88 190/95 205/103 ' 5001-5500 140/70 155/78 170/85 185/93 200/100 ' 215/108 5501-6000 150/75 165/8a 180/90 195/98 210/105 225/113 Equation 11-1 (0.02 x square feet of conditioned space) + I15 x (number of bedrooms + 1)] Totatventtlatlon rate (cfm) Conditioned space includes the basement 1 If conditioned space exceeds 6000 sq. ' it or there ere nq e_ tlian 6 bedrooms, use Bquetion'11-1 froinSedioaN11042 to calculate total ventilation rate. Total ventilation —The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, for each one -hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventila- tors (ERV) the average hourly ventilation capadty must be determined In consideration of any reduction of exhaust or out outdoor air intake, or both, for defrost or other equipment cycling. Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 44 cfm, shall be provided, on a con- tinuous rate average for each one -hour period. The portion of the mechanical venbilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met Page 1 of 6 Section B Ventilation Method . • lamas either balanced ar embattle only) NI Balanced, HRV (Heat Recovery Ventilator) or E W (Enemy Rem- 0 Briniest only ery Venttatarl-cfm dentin law must not exceed continuous vents- Continuous Fan rottenly' cfm Winn rating by more than 100%. - Law the: 96 High cfm ', ; Continuous fan rating in cfni.(tapacity mast not exceed _ 14,1 _ continuous ventllation rating by more than 100%) Directions -Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typicbr(ly ?JRV or ERV'5 Enter tine !ow and high elm amounts. Low cfm airflow must be equal to or greater than the squired continuous ventilation rate and less than 100% greater than the Continuous rate. (For Instance, if the law cfm is 40 cfm,-the ventilation fan must not exceed SO cfm_) Automatic controls may allow the use of a largerfan that is operated a percentage of each hour. Section C Ventilation Fan Schedule Description M) 9 Location likkec (-Do Continuous Intermittent 3 /86 . Directions -The ventilation fan schedule should describe what the fan ks far, the location, cfm, and whether It is used for continuous arhrtermittent ventilation. The fan that is chose for continuous ventilation must he equal to or greater than the/ow cfrn air rating and lets than 100% greaizr than the continuous rates (far instance, the low cfrn Is 40 cfm, the continuous ventilation fan must not exceed 80 cfm.) Automatic controls may allow. the use of a larger fan that Is operated a percentage of each hour; . Section D Ventilation Controls • (describe operation and antral of the continuous ous and intermlttentventilation) 42A tea. Directions - Describe the operation of the ventilation system. There should be adequate detail for plan reviewers andInspectors to verb desk and installation compliance Related trades also need adequate detail forplacement of controls and proper operation tithe bulIdtng ventilation. If exhaust faits are used forburdding ventilation, describe the aperatfon andlocotion of any controls, indicators and legends. Ilan ERV orHRVlsto be lnstalle4 describe how it will beOstalled. if it will be connected and ►nterfaced with the air handling equipment please describe such corutertians as detailed in the manufactures' lnsmllalion hnstni lions. if the installation las rualans regbhfre orrecommend the equipmentto be 6rtLdu.kud with the airbandring equipment for proper operation, such interconnection shall be made and described Make-up air (vv ‘ i f., ,•' Passive (determined from calculations kern Table's 1 ,) Pawared (determined from eaiatlatins s from Table SOL3i1) Interlocked vdth exhaust device (determined frare caicu)ation from Table5013.1) Other, describe: Location of duct or system ventilation make-up air: Betermined from matte -up air opening table ' Cam I l Sae and type (round, rectangular, fix or right) (NB means not required) - Page 2 of 6 N d N M M N • N 81 N M N M N M N N. N N M M Aa -N N M. Ad N M td 61 M N N u M m N' M N M' N NI N m N e N m N u N tt N n m A.Usethis coloranif there are other then fan -assisted o a y dgas orO17Cpp . d B.Use this coinnm if there is one fan -assisted appliance pet venting system. Other than atmospherically vented appliances snag also bainoltded. C.Use this column ifthere Is one atmasphedcally vented (other team fan-esslited) gas or mll applancepemendag syst m or one solid ihel appliance. N D.Use this column if there are multiple atmospherically vented gas or oil appiiuncer using a common vent as if there am atmospherically seated gas or oil 61 • appliances end solid fuel appliances. TABLE 50't.4.1 0 DETERMINE MAKEUP AIR QUANTITY FOR E GIAUSTAPPLIANCES IN DWELLING UNITS - . ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR H0 COMBUSTION APPUANCESA' ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR D6CTYENT APPLIANCES' ` ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE 0R ONE SOLID FUEL APPLIANCE° MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS DR OIL APPUANCES OR SOU° FUEL APPLIANCES° to Estimate House 1.1M:ration . 1. Use the Appropriate Column a) pressure factor0.15 • 0.09 0.06 0.03. - b) =Maned floor area (si) — 40 — — (iecluding m%finishedbasements) Estimated $Ouse• %QttBtiott (CiIIt). [la x lb] - ff,,,Z'] `-� 1.C(J(,.(. I — . — 2. Eahauat Capacity a) clothes dryer135 135 135 .135 ' b) 80% of largest exha rating (dm): �I /� `7 — — -- (not applicable if recirculating system orif powered makeup afr is electdca lyinterlocked and matched to exhaust) c) SO% of next largest eithanstxating (te): —• -- net (not appticableirecimulating system orifpowered makeup airis electrically intetioelred and matched to exhaust) . TotaLHxhaust Capacity (dm): (2a-W.13+2c] — 37 5 — — — . 3. Makeup AirRequirement . . • . . a) Total Pxbeust Capacity ab �j <_ — "' J • — b) Estimatedliousa Infiltration (from above) - j n �' % — — — �� Makeup Aar Quality -(col): (3a-3b] ..L....L..-7 - .2.57t .+ — — (if value is negative, no - makeup air is needed • • Table 501.4.2. 4. For betaken, Air Opening Sizing, teferio 38 2015 MINNESOTA MECHANICAL CODE EXHAUST SYSTEMS TABLE 501.4.2 NG TABLE FOR NEW AND EXISTING DWELLING UNITS TYPE OF OPENING OR SYSTEM ,•L•,• ••. _ _ - ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPUANCES OR NO CONISUSTION . ApPLIANCES° ONE OR MULTIPLE FAN- ASSISTEDAPPUANCES AND POWER VENT OR DIRECT C° APPLIANES ONE ATMOSPHERICALLY VENTED GASOR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCE° MULTIPLE APPUANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APOR PLIANCES FUEL APPUANCES° PASSIVE MAKEUP AIR IAM ° (aim) (efm) . (clm) (afm) (lnehes) Passive opening 1-36 1-22 . 1-15 1-9 3 Passive opening 37-66 ' 23-41 16-28 10-17 4 Peeve 67-109 • 42-66 29-46 18-28 5 opening Passive opening - 110-163 67-100. 47-69 29-42 6 Passive opening 164-232 101-143 70-99 . 43-61 7 233-317 144-195 100-135 62-83 8 Passive opening Passive opening with motorized _ 318-419 196-258 136-179 84-110 . 9 420-539 259-332 ISO-230 111-142 10 Pave op • with motorized damper Passive opening with motorized � 540-6'79 333-419 231-290 ' 143-179 11 damper Powered makeup > 679 > 419 > 290 > 179 Prot aqeble pp yid gas Oil appJiaetee3 arlf heza a a.)no C,O�i�nbt t1OR tip m A.Use this tnlnmu theme ate OW than C-a&S d Or Ser venting ti� Q� $ ap " ce may also ba led le B. T>m this caivam if theseis one fmQ-asaistad cq�gGanuperaroma slid final C. Use this adman if there is one vented (other then fan-aassisted) gas or ail appliance 1 venting sysiam apple. N atmospherically atlno d a common vent at if there are atmlosphesiaany vented gas or oil 1.1 D. Use this column if mere are multiple Y vented gas or oil appliances rasing . appliances and solid fuel appliances. E. An equivalent length of 100 fed of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet fee each 90-degree elbow to14 della:mine the remaining length of airiest duct allowable. N P. If Seaga duceis ased, increase the duct dianieterby one inch. Flexible duct shall be st et ]ied with minimal sags. re 0. Barometric dampers are profited inpassive rnalanspair openings when any atmosphedcally vented appliance is Installed. m 13. Powered makeup air shall be electrically interlocked with the largest eshmrst system 37 - 2015 MINNESOTA MECHANICAL CODE Directions -The Minnesota Fuel Gas Code method to cakrdate to size of a required combustion air opener is called the Known Air Infiltration Rate Method. For new corrstruttfon, 4b of step 4 Is required to be filled out. tr4CAppendix E. Worksheet E1 Residential Combustion Air Calculation Method (for Furnace, Boller, and/or Water Heater in the SanteSpace) c"' ' Step 1:CAmplebevented combUstkmappliancahlfoi,umilwI. Fan Assisd iced Vent input Btu/hr I.:7 __D _ ruStc or Power Vent �e r 14 , Water Heater: • Draft Hood Fan Assisted Direct Vent input etti/hr _ or Power Vent Step 2:Calculate the volume af the Cuxnbustton AppUance Space (CAS) containing combustion appliances. The CAS b dudes all spacesconnected to one another by code compliant openings. CAS volume: fe LxWxH L W H Step 3: DetermineAtrchanges per Hour (ACH)1 Default ACH values have been hscorporated into Table E 1 for use with Method 4b (iCAIR Method). If the year of construcrian orACHis not Imown, use method 4a (Standard Method). Step 4: Deterndne Required Volume forCombustlon Mr. (DO NOT COUNT DIRECT VENTAPPUANCES) 4a.Standard Method Total Btu/hrinput ofall combustion appliances Input Btu/hr fe Use Standard Method column In Table E-1 tofind Total Required TRV: fe . Volume (IRA If CAS Volume (from Step 2) fsgreater'him TRV then no outdoor opener are needed. If CAS Vohmse(fromStep 2) IsressthunTRY then go to STEP S. 4b. Known Mr htfiitration Rabe (CAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES) Total Btu/hrinput af ail fan -assisted and power yard appliances Input Btu/hr • Use Fan -Assisted Appliances column &Table E1to fhd RVFA: - fta Required Volume Fan Asked (RVFA Total Btu/hrInput of all Natural draft appUances input Btu/hr Use Natural draft Appliances column In Table Ei to find RVNFA: fe Required Volume Natural draft appliances (RVNi A) Total RegWred Volume (TRV) =RVFA + iWNDA TRV = + = TRV If CAS Volume Morn Step 2)fsgreaterthanTRV then no outdoor openings are needed. If CAS Volume (from Step Waist then go to STEP-S. Step S:Calcolatethe ratio of availatdeinteriorvtdume to the total required volume. Ratio=CAS Volsxne (horn Step 2) divided byTRV (from Step 4a or Step 4b) Ratio = / _ Step 6: Calculate Reduction Factor(RF). RF=1atnusRatio RF=1_ _ - Step 7: Calculate single outdoor opeoingas ifalt combustion air Is from outside. Total Btu/hrInput dell Combustion AppfaruesCn the same CAS Input Btu/hr (EXCEPT DIRECT VENT) Combustion Air opening Area (CADA): i Total rdrvrdedby3000 Btulhr perina CADA= /3000lttu/hr per �= in Step tC Calculate IWIrthnum CADA MUNmum CAQA=CADAmuftipitedby RF MlnJmum CADA= x = in1 Step 9: Calculate Combustion Air Opening Diameter(CAOD) the square root ofMhttmumCAOA CAOD=1.134 Minimum CAOAa in. diameter CAdo=1.13muItfpUedby go up one Inch inshe li using ilex duct 1 If dashed, ACH an be determined using ASHRAE caiwlatian or blower door test- Follow procedures in Section G304. Page 5 of 6 • Residential Combustion air IFGC Appendix E, Table E-1 (Required Interior Volume Based on Input Rating of Appliance) Input Rating (8tu/hr) Standard Method Known Air Infiltration Rate (KAMR) Method (cu ft) Fan Assisted or Power Vent Natural Draft 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 • 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 - 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,00000 4,200 2,100 45,000 2,250 3,375 1,688 4,725 . 2,363 50,000 2,500 3,750 1,675. 5,250 2,625 55,000 • 2,750 " 4,125 2,063 . 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 ' 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 J 90,000 • 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 , 110,000 5,500 8,250 4,125 11,550 . 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9.000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 ' 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,040 8,250 _12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 _ 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9;750 .14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,783 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 _ 8,063 22,5'75 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,875 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 L The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table Is 0.20 ACN. 2. This section of the table Is to be used for dwellings constructed prior to 1994. The default KAIR used In this sexton of the table is 0.40 ACIi. Page 6 of 6 City Inspection Dept. Copy City Forester Copy Applicant/Builder Copy EAGAN INDIVIDUAL RESIDENTIAL LOT TREE PRESERVATION PLAN SUMMARY CITY OF EAGAN FORESTRY DIVISION 651-675-5300 (BUILDER, PLEASE READ ATTACHMENTS) Development Lakeside of Eagan Lot Number Address Builder 2 3797 Lakeside Ct Block Number 1 Norton Homes Phone Number: 763-559-2991 Contact: Pat Hiller Tree Protection Requirements: X Tree Protection Fencing Installed on Site (orange 4' poly fence) X Oak Tree Pruning (Immediately seal wounds during April 1 to July 31) Therapeutic Pruning Required Retaining Wall To Be Installed Other: Replacement Trees: X Not Required As Follows: Attachments: X Yes (Refer to attached documents for details) No Additional Notes: EAGAN FORESTRY DI ISION DATE: 3/23/2020 NOTES: i mcn A1A2![1S A0 aLVJId1.LNAJ li 1.41". I LAKESIDE COURT iti ii ill ; I is 1 ., *s..r, ii$iA 'Illl"A 14111139 "�-aA :fit Ott036 119 �`s�e lied J TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT EAGAN Date Building Permit Application Received 3/16/2020 Development Lakeside of Eagan Site Address 3797 Lakeside Ct Lot 2 Block 1 Builder Norton Homes Telephone 763-559-2991 Property/Lot Owner Name - Telephone - Contact Pat Hiller E-mail E-mail - Office Plan Review — Date 3/20/2020 Notes All significant trees in house construction area were removed with initial development. Development only had 39.1% removal. No mitigation is required for any lot, unless there is additional tree removal. Tree Preservation Data Original Plan Revised Plan Total Significant Woodland Area sq. ft sq. ft Total Significant Trees Woodland To Be Removed sq. ft sq. ft Trees To Be Removed Allowable Woodland Removal (20%) sq. ft sq. ft Allowable Tree Removal (20%) Required Mitigation YES (or) NO Calculated Mitigation Amounts Original Plan - Category A Category B Category C Revised Plan - Category A Category B Category C Site Inspection — Date 3/23/2020 Notes 1) House Location is staked 2) Original silt fence / tree protection fencing is still up but. should be reset. G:\Forestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docc Original Tree Preservation Plan Approved — Date 3/23/2020 Forwarded to Inspections — Date 3/23/2020 Discussion/Meetings with Builder/Owner - Notes Revised Tree Preservation Plan Approved — Date By Forwarded to Inspections — Date By Additional Field Inspections Date Notes Date Notes Date Notes Date Notes G:\ orestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docx Was the approved Tree Preservation Plan followed? YES (or) NO If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below) Final Site Inspection — Date Notes Additional Notes and/or aerial photo image (insert aerial image or draw map of site) G:\Forestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docx 02017 Westwood Professional Services, Ine. Drainage & Utility Area = 36, 785.31 sf rrr— Drainage & /1\ I \ I I \ \B L 0 I\ \ \ \ I \ I \\ 1 Drainage & Utility / \\\\Area = 58,851.12 sf \ `. Utility • • C K / • • • • • • • \ \ Drainage & Utility 11 Area = 36, 653. 901 1 sf I / / I / 1 / Easement--4,/ • • • 1 Lot 4 \ 48,142.90 sf / \ \ \ 4 Lot 3 \ \ 45,226.31 sf\ \ \ 3 \ 1 12,06` 92 sf Drainage & Utility ( 1 \ Area = 23,830.83 sf 1 Lot 1 O 30, 368.83 sf — --Drainage & Utility Easement i \ sf L 2 Lot 2 69,157. 12 N IA/r-^t•/'1TT YY L_.ivV / / C,/n A n 1 \ V/-1 L 1 Total Boundary = 204,963.072 sf or 4.705 acres a' i Westwood dim 0162)1074,10 /NE MEnwanw ►� IEE2)0874t22 Erahune.1161 YEY ?m (OM NtNW-•---*-MM ��AEW rAni� Lakeside of Eagan Eagan, Minnesota 80' 160' Sheet 1 OF 1 Date 1/16/2018 0012565APF01.dwg Area Map i \ S754 5364 r " 5391 512 5441 3442- 5440. 5377 5376 5375. 5119 5116� 5373--, 5125 5372 -- 5121- 5124 51070 5112 5361 51 t`t_ 3117 .\ 5115 5114 5120 511 5122 5112 5111 �51 ) .:r.� �-s"'��.• 4L:212—.Lr~i.--ii�iy,.--LU1*: -.I ` 7.5 Ki���r i1t aiiat MMIN M1■ �O111ii4711 ��u�/�' �oim 1�r _._.i,6 0mr6r��� ' ��IN�16•ZSLR9/ur.7c.�iZT�'�---1:1_i le I � mum- 1 5199 52 52 4 silt' 6I h, �4 5p7o 5oafi 4 5071 pson SQ;S9 e, 5069 5075 5076 i\ I! \ :)7, 5059 5034 5056 5061 5077 Im„ 441 5037 5046 5046 5026 3025 5016 b'0 O oa i; `, gip TREE PROTECTION FENCE` TREE PROTE FENCE 5297 5330 4 5793 5216 DD 1 DD PROPERTY LEGAL: LOT SURVEY CHECKLIST FOR RESIDENTIAL BUILDING PERMIT APPLICATION Lot 2, Block 1, Lakeside of Eagan DATE OF SURVEY: 3/26/2020 LATEST REVISION: -7' 7 L �//s, �de C . c co O Z Q DOCUMENT STANDARDS O 0 ❑ • Registered Land Surveyor signature and company ✓❑ ❑ ❑ • Building Permit Applicant O 0 0 • Legal description 0 0 ❑ • Address O 0 0 • North arrow and scale O 0 0 • House type (rambler, walkout, split w/o, split entry, lookout, etc.) 0 ❑ 0 • Directional drainage arrows with slope/gradient % O 0 0 • Proposed/existing sewer and water services & invert elevation 0 ❑ ❑ • Street name ❑✓ ❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.) ✓❑ 0 ❑ • Lot Square Footage 0 ❑ 0 • Lot Coverage ✓❑ ❑ ❑ ❑✓ ❑ ❑ ❑✓ ❑ ❑ ❑✓ ❑ ❑ O ❑ ❑ EOM El ❑ ❑ O ❑❑ a❑❑ ✓❑ ❑ ❑ O ❑❑ ✓❑ ❑ ❑ No MEM O ❑ 0 E ✓ � C ELEVATIONS Existing • Property comers • Top of curb at the driveway and property line extensions • Elevations of any existing adjacent homes • Adequate footing depth of structures due to adjacent utility trenches • Waterways (pond, stream, etc.) Proposed, • Garage floor • Basement floor • Lowest exposed elevation (walkout/window) • Property comers • Front and rear of home at the foundation • PRV Required PONDING AREA (if applicable) • Easement line • NWL • HWL • Pond # designation • Emergency Overflow Elevation • Pond/Wetland buffer delineation • Shoreland Zoning Overlay District • Conservation Easements DIMENSIONS • Lot lines/Bearings & dimensions • Right-of-way and street width (to back of curb) • Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc. (i.e. all structures requiring permanent footings) • Show all easements of record and any City utilities within those easements • Setbacks of proposed structure and sideyard setback of adjacent existing structures • Retaining wall requirements: Reviewed By: Dave Westermayer Date 4/1 /2020 G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19 S89°56'08"W 39.66 S81°34'14"E 161.08 LOT 1 50 25 0 25 50 SCALE IN FEET 100 Rat \ BLOCK l \ LOT 2 EASEMENT PER DOC NO 3169807 --EDGE OF WATER PER PLAN --- RETLAND JP43.2 HWL = 695.70 OUTLET 895.0 \ \/ SI31a34t14"E/ 19,08 EDGE OF WATER PER PLAN WETLAND JP43.3 HWL-898.1 OUTLET.897.5 II---'- EAG�1- GLNL�,tttiNu E-,._.r _ 898.9 3:1 Maximum Slopes / or i :_'raining Wall Witi / ®H Fiequ,red toT N WET 899.3 3a NbsCaw =b2i 901.10 33 EXISTING LO CF - 906.0 TF - 907.3 LO - 901.8 BF - 898.6 a 901.0 904.3 / BY:. DATE: BUILDING INSPiCTiONS DIVIS;Dial /a 906.3 L 9Kes', c,16- LOT 4 • 90s.8 9085 0) 05 92 )'P+a _ y .` ! - ik 11,1 \ 7/_t/A 1 \ \ \ \ \ 906.8 w 3LAKESIDE COURT , q- 903.5 DESCRIPTION OF PROPERTY SURVEYED Lot 2, Block I, LAKESIDE OF EAGAN, according to the recorded plat thereof, Dakota Couty, Minnesota. STANDARD NOTES I) Site Address: 3797 Lakeside Cant, Eagan, Minnesota 55123 2) A title opinion was not furnished to the surveyor as pan of this survey. Only easements per the rewN d plat are shown unless otherwise denoted hereon. 3) Benchmark: TNII fru La 1 & 2, Block I, LAKESIDE OF EGAN -906.27 Feet 4) Principal Structure Swbarlu-Front: 30 fen - Side: 6 feet Living, 5 feet Garage Please note that the general restrictions for the subject property may have been amended through a city process We could be unaware of such amendments if they are in a recorded document provided to us. We recommend that a zoning letter be obtained from the Zoning Administrator for the current restrictions for this We have not received the current awing classification and building setback requirements flan the insurer. 5) Utmder We have shown the location of utilities on the surveyed property by observed evidence only. There may be underground utilities encumbering the subject property we are unaware. Please note that we have not placed a Gopher State Onc Call for this survey. There may or may not be underground utilities in the mapped area, therefore extreme caution must he exercise before any excavation takes place on or near this site. Before digging, you are required by law to notify Gopher State One Call at least 48 hours in advance at 651i454.6002. 6) Grading must maintain a minimum 2% slope gradient to accommodate positive drainage. 7) MI set offset irons are measured to hundredths of a fat and can be used M benchmarks for construction 8) The proposed driveway shown is conceptual only and does not putpon to show exactly how the driveway shall he built 9) Proposed grades shown adjacent to building foundation refers to top of black dirt 10) Verily unitary service invert prim to any concrete work. iNST2tER E U. CONTROL. Development Plan Data - WO Garage Floor Ekvarion Basement Floor Elevation Proposed Elevations - LO Proposed Garage Floor Elevation Proposed Top of Foundation Elevens. Proposed Inokou1 Opening Elevation Proposed Basement Flom Flevmion Building Cover La Area - 69,158 S.F. Upland Area - 43,831 S.F. Pond Area - 25,307 S.F. House Area - 2,215 S.F Cos erage- 5.I% .91010 Step Drip) .903.5 -907.7 (1' Drop) = 909.0 = 903.5 Offset Irons (He,*N4m are to the tap of pipe) OS a1-901.28 OS 02-907.57 OS ad- 901.20 OS 83- 902.05 Bearkps are based on the Henneph County Coordinate System (NOD 83 - 1986 adj.) 20 10 0 10 20 SCALE IN FEET SURVEY LEGEND 40 O• CAST IRON MONUMENT • CATCH BASIN d FLARED END SECTION DO GATE VALVE ▪ GUY WIRE Vr HYDRANT O SURVEY MONUMENT SET • SURVEY MONUMENT FOUND Ah SURVEY CONTROL POINT M LIGHT POLE Ma POWER POLE )( SANITARY MANHOLE Q SANITARY CLEANOUT SIGN zz.5 GROUND ELEVATION ® STORM DRAIN ® STORM MANHOLE D YARD LIGHT ® A/C UNIT WELL WOE WALKOUT ELEVATION FEE FIRST FLOOR ELEVATION GEE GARAGE FLOOR ELEVATION TOE TOP OF FOUNDATION ELEV LOE LOWEST OPENING ELEV. C CABLE TV PEDESTAL m ELECTRIC TRANSFORMER m ELECTRIC MANHOLE O ELECTRIC METER O GAS METER O GAS VALVE ® HAND HOLE SOIL BORING �3 TREE CONIFEROUS o TREE DECIDUOUS m TELEPHONE MANHOLE M TELEPHONE PEDESTAL TRAFFIC SIGNAL O UTILITY MANHOLE 61 UTILITY PEDESTAL BITUMINOUS - BUILDING SETBACK LINE - OTV- CABLE TV CONCRETE CURB (CONCRETE 'Pao _ -- CONTOUR EXISTING -�� CONTOUR PROPOSED GUARD RAIL - 0T - DRAIN TILE - DC- ELECTRIC UNDERGROUND -a-a- FENCE - f0 - FIBER OPTIC UNDERGROUND - OAS- GAS UNDERGROUND - old- OVERHEAD UTILITY +HFHH41) 111F RAILROAD TRACKS -a- SANITARY SEWER STORM SEWER - TELEPHONE UNDERGROUND - tat- UTILITY UNDERGROUND - I - WATERMAIN FIELD CREW NO. BY DATE REVIBpN 00 DY JPR 3/282020 BULD9VG COVER CALCULATION DRAWN 2 EME 4R(2020 CITY COMMENTS JPR CHECKED DEIP DATE 22820 USE (INCLUDING COPYING. DISTRIBUTION. AND/OR CONVEYANCE OF INFORMATION) OF THIS PRODUCT O STRICTLY PROHIBITED WITHOUT SATHRE-BERGOUIST, INC.'s EXPRESS WRITTEN AUTHORIZATION. USE WITHOUT SAID AUTHORIZATION CONSTITUTES AN ILLEGITIMATE USE AND SHALL THEREBY INDEMNIFY SATHRE-BERGOUIST. INC. OF ALL RESPONSIBILITY. SATHRE-BERGOUIST. INC. RESERVES THE RIGHT TO HOLD ANY ILLEGITIMATE USER OR PARTY LEGALLY RESPONSIBLE FOR DAMAGES OR LOSSES RESULTING FROM ILLEGITIMATE USE. I hereby certify that this survey, plan or report was prepared by me or trader my direct supervision and that I am a ddy Licensed Laud Surveyor under the laws of the State of Minnesota. Dated this 6th day of March, 2020. Daniel L. Schmtdt, PLS Minnesota License No. 26147 scbmjdl@sathre.com SATHRE-BERGQUIST, INC. 150 SOUTH BROADWAY WAYZATA, MN. 55391 (952) 476.6000 WVVW.SATHRECOM T W P:027-RG E.023S EC.14 Dakota County EAGAN, MINNESOTA CERTIFICATE OF SURVEY PREPARED FOR: NORTON HOMES FILE NO. 64685-008 PERMIT City of Eagan Permit Type:Plumbing Permit Number:EA167475 Date Issued:03/17/2021 Permit Category:ePermit Site Address: 3797 Lakeside Ct Lot:2 Block: 1 Addition: Lakeside Of Eagan PID:10-44305-01-020 Use: Description: Sub Type:Residential Work Type:Replace Description:Water Softener Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State Building Code). Please call Building Inspections at (651) 675-5675 to schedule a final inspection. Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087 Surcharge-Fixed $1.00 9001.2195 $60.00 Total: I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State of Minnesota Statutes and City of Eagan Ordinances. Contractor:Owner:- Applicant - Norton Homes Llc 18215 45th Ave Nw Ste D Plymouth MN 55446 (612) 384-7309 Milbert Company (culligan) 1801 50th St E Inver Grove Heights MN 55077 (651) 451-2241 Applicant/Permitee: Signature Issued By: Signature