3797 Lakeside Ct-,.INIW L /�2 - 11, istp.Cic(
' pL /6 a.270 - /00 b 0
2020 _/62271 - /ov •0 0
G AN
3830 PILOT KNOB ROAD I EAGAN, MN 55122-1810
(651) 675-5675 I TDD: (651) 454-8535 I FAX: (651) 675-5694
bu ildinoinspectionsCa.cityofeagan.com
�b-W/67 72
2020 RESIDENTIAL BUILDING PERMIT APPLICATION
Date: 3/16/2020 Site Address: 3797 Lakeside Court Unit #:
I E�
For Office Use f i4 6
Permit #: J 6 �� , 6 i
Permit Fee:, 1/ 3S 6f
eii
Date Received:
Staff:
Resident/
Owner
Name: Norton Homes, LLC Phone: 763-559-2991
18215 45th Ave N Ste D Plymouth MN 55446
Address / City / Zip:
�!�
Applicant is: Owner Contractor / - e - 1 (,, �p .c, (,tx b �`` ''
Type of Work
Description of work: New Residential 2 story �f
Construction Cost: 475'000 Multi -Family Building: (Yes / No ✓ )
Contractor
Company: Norton Homes, LLC Contact: Patrick Hiller
Address: 18215 45th Ave N Ste D City: Plymouth
State: MN Zip: 55446 Phone: 763-559-2991 Email: path@nortonhomes.com
License #: BC639221 Lead Certificate #:
If the project is exempt from lead certification, please explain why: �``�
/`
In the last 12 months,
Yes i✓ No
COMPLETE THIS AREA ONLY IF CONSTRUCTING A NEW BUILDING
has the City of Eagan Issued a permit for a similar plan based on a master plan?
If yes, date and address of master plan:
Licensed Plumber:
Mechanical Contractor:
Sewer & Water Contractor:
Fire Suppression Contractor.
Mike's Custom Mechanical Phone: 763-568-7148
Mike's Custom Mechanical Phone: 763-568-7148
DSM Excavating Company Inc Phone: 651-480-1355
Phone:
NOTE: Plans and supporting documents that you submit are considered to be public information. Portions of the Information may be
classified as non public if you provide specific reasons that would permit the City to conclude that they are trade secrets.
You may subscribe to receive an electronic notiticatlon from the City of proposed ordinances by signing up for an email update on the Clty's
webslte at www.cityofeagan.comisubscribe.
Exterior work authorized by a building permit issued in accordance with the Minnesota State Building Code must be completed within 180
days of permit Issuance.
CALL BEFORE YOU DIG. Call Gopher State One Call at (651) 454-0002 for protection against underground utility damage. Call 48 hours before you
intend to dig to receive locates of underground utilities. www.gopherstateonecaliorg
I hereby acknowledge that this information is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of
Eagan; that I understand this is not a permit, but only an application for a permit, and work is not without a permit; that the work will be in
accordan th the approved plan in t ca e of work which requires a review and approval of pla
(c(C
Applica is PrytedNe,
,�'r
x
Applicant'
Sig
3 -7ti-7 LFlk;dE C�. 6sr'
DO NOT WRITE BELOW THIS LINE
SUB TYPES
Foundation Fireplace
Garage
Deck
Lower Level
' Single Family
Multi
01 of _ Plex
WORK TYPES
New
Addition
Alteration
Porch (3-Season) Exterior Alteration (Single Family)
Porch (4-Season) Exterior Alteration (Multi)
_ Porch (Screen/Gazebo/Pergola) _ Miscellaneous
Pool Accessory Building
Interior Improvement
Move Building
Fire Repair
Replace _ Repair
Retaining Wall
DESCRIPTION
Valuation yy7 Ogg
Plan Review
(25%_ 100% 14
Census Code /o/
#of Units /
# of Buildings
Type of Construction
REQUIRED INSPECTIONS
Footings (New Building)
Occupancy
Code Edition
Zoning
Stories
Square Feet
Length
Width
Footings (Deck)
Footings (Addition)
Foundation , Foundation Before Backfill
Roof: bt Ice & Water Y Final
Framing 30 Minutes
Fireplace: Rough In
Insulation
Sheathing
Sheetrock
Fire Walls
Braced Walls
Shower Pan
1 Hour
it Test Final
Reviewed By:
RESIDENTIAL FEES
Base Fee
Surcharge
Plan Review
MCES SAC
City SAC
Utility Connection Charge
S&W Permit & Surcharge
Treatment Plant
Radio Meter Read
Copies
TOTAL
Siding
Reroof
Windows
Egress Window
_ Demolish Building*
Demolish interior
Demolish Foundation
Water Damage
*Demolition of entire building — give PCA handout to applicant
TA/f✓ i / MCES System
/5- SAC Units
g. / s City Water
Booster Pump
2.330 PRV
✓f' 1? Fire Suppression Required
60
y0
NO
Meter Size:
Final / C.O. Required
Final / No C.O. Required
HVAC _ Service Test Gas Line Air Test _ Hood
Pool: _Footings _Air/Gas Tests _Final
Drain Tile
Siding: Stucco Lath tone Lath _Brick _ EFIS
Windows
Retaining Wall: _ Footings _ Backfill _ Final
Radon Control
Fire Suppression: _Rough In _Final
t* Erosion Control
Other:
nr
, Building Inspector
cjgp,4
//.i 9 tzQ 9*S
/ Et PQ2 / 3?8' 2 9
:Ldi Aft. l- /6 V @ q5 -
Gam- ?37 '0 6'o4i
3 940
OP
/00 079 /7
/ 3/ `j/( 44'
33 r 3
Goto 616
Page 2 of 3
Peggy Fleck
/i.2ie
From: Pam Dudziak
Sent: Wednesday, July 08, 2020 12:17 PM
To: Peggy Fleck
Subject: RE: 3797 Lakeside Ct - L2, B1 Lakeside of Eagan
Yes, you can remove this hold. I reviewed the survey and it satisfies the applicable R-1S zoning standards.
Pam Dudziak
Planner
3830 Pilot Knob Rd I Eagan, MN 55122
Office: 651-675-5691
https://www.cityofeagan.com
Original Message
From: Peggy Fleck <pfleck@cityofeagan.com>
Sent: Tuesday, July 7, 2020 9:12 AM
To: Pam Dudziak <pdudziak@cityofeagan.com>
Subject: 3797 Lakeside Ct - L2, B1 Lakeside of Eagan
Pam,
Jeff brought this permit app up for me to process. There is a pop up that says not to process until you have given your
approval on the site survey. It is okay to process and can I remove the hold?
Thanks,
Peg
Peggy Fleck
Clerical - Community Development
3830 Pilot Knob Rd I Eagan, MN 55122
Office: 651-675-5674
https://www.cityofeagan.com
1
New Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or In the electrical distribution panel.
Date Certificate Post'
IS V IJCV
6/15/2020
Mailing Address of the Dwelling or Dwelling Unit
3797 Lakeside ct
City
Eagan
NORTON I HOMES
Name of Residential Contractor
Norton Homes, LLC
MN License Number
BC639221
/‘ .P6'0/
THERMAL ENVELOPE
RADON CONTROL SYSTEM
Insulation Location
Type: Check All That Apply
Passive (No Fan)
Non or Not Applicable
0
m
i
m
5
rn
ti
Foam, Closed Cell
Foam Open Cell
Mineral Fiberboard
Rigid, Extruded Polystyrene
:
Active (With fan and monometer or
other system monitoring device)
Location (or future location) of Fan:
Other Please Describe Here
Below Entire Slab
Foundation Wall
R-10
Perimeter of Slab on Grade
Rim Joist (1st Floor)
R-20
Rim Joist (2nd Floor+)
R-20
Wall
R-20
Ceiling, flat
R-49
Ceiling, vaulted
R-49
Bay Windows or cantilevered areas
R-20
Floors over unconditioned area
R-30
Describe other insulated areas
Building envelope air tightness:
Duct system air tightness:
Windows & Doors
Average U-Factor (excludes skylights and one door) U:
0.22
Heating or Cooling Ducts Outside Conditioned Spaces
Not applicable, all ducts located in conditioned space
Solar Heat Gain Coefficient (SHGC):
0.28
R-value
MECHANICAL SYSTEMS
Make-up Air Select a Type
Appliances
Heating System
Domestic Water
Heater
Cooling System
Not required per mech. code
Fuel Type
Natural gas
Electric
Electric
Passive
Manufacturer
Amana
Rheem
Amana
Powered
Model
Rating or Size
ACS92100
Input In
BTUS:
100k
2 -50 gallon electric
Capacity In
Gallons:
100
ASX13036
Output
In Tons:
3
Interlocked with exhaust device.
Describe:
Other, describe:
Efficiency
AFUE or
HSPF%
92%
SEER
/EER
13
Residential Load Calculatit
Heating Loss
Heating Gain
Cooling Load
Location of duct or system:
80193
26708
31739
Cfm's
" round duct OR
MECHANICAL VENTILATION SYSTEM
metal duct
Describe any additional or combined heating or cooling systems if installed: (e.g. two fumaces or air
source heat pump with gas back-up fumace):
Select Type
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
Low.
Low.
90
High:
High:
200
Combustion Air Select a Type
Not required per mech. code
Balanced Ventilation capacity in cfms:
Passive
Other, describe:
Location of duct or system:
Location of fan(s), describe: lbath fans(4-80 2-50), kitchen (300), hry (200
Capacity continuous ventilation rate in cfms:
90
Cfm's
round duct OR
Total ventilation (Intermittent + continuous) rate in cfms:
920
" metal duct
/6 .�
REVISED
6/15/2020
3797 Lakeside Ct, Eagan
HVAC Load Calculations
for
Norton Homes
Plymouth, Mn
RHVAc HVAC Ls
Prepared By:
Amanda Fisher
Mikes Custom Mechanical, Inc
Po Box 171
Champlin, Mn 55316
763-568-7148
Thursday, June 11, 2020
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Mike's Custom Mechanical, Inc . % 3797 Lakeside Ct, Eagan
Dayton. MN 55327 Page 2
Project Report
General Project Information
Project Title: 3797 Lakeside Ct, Eagan
Designed By: Amanda Fisher
Project Date: Monday, March 9, 2020
Client Name: Norton Homes
Client City: Plymouth, Mn
Company Name: Mikes Custom Mechanical, Inc
Company Representative: Amanda Fisher
Company Address: Po Box 171
Company City: Champlin, Mn 55316
Company Phone: 763-568-7148
Company E-Mail Address: info@mikescustommechanical.com
Company Website: www.mikescustommechanical.com
Design Data
Reference City: Minneapolis/St. Paul AP, Minnesota
Building Orientation: Front door faces West
Daily Temperature Range: Medium
Latitude: 44 Degrees
Elevation: 834 ft.
Altitude Factor: 0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb ReLdum ReI.Hum Dry Bulb Difference
Winter: -15 -15 n/a 30% 70 31.02
Summer: 88 71 44% 50% 75 24
Check Figures
Total Building Supply CFM: 1,147 CFM Per Square ft.: 0.180
Square ft. of Room Area: 4488 sq ft -6Teee" Square ft. Per Ton: 2,412
Volume (ft3): 48,666
Building Loads
Total Heating Required Including Ventilation Air: 180.193 Btuh 80.193 MBH
Total Sensible Gain: 26,708 Btuh 84 %
Total Latent Gain: 5,031 Btuh 16 %
Total Cooling Required Including Ventilation Air. 31,739 Btuh 2.64 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\3797 Lakeside Ct, Eagan.rh9
Thursday, June 11, 2020, 6:21 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Mike's Custom Mechanical, Inc 3797 Lakeside Ct, Eagan
Dayton. MN 55327 Pd Page 3
Miscellaneous Report
System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: -15 -15 100% 30% 70 31.02
Summer: 88 71 44% 50% 75 23.51
Duct Sizing Inputs
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor. 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration Specified: 0.280 AC/hr 0.150 AC/hr
227 CFM 122 CFM
Infiltration Actual: 0.199 AC/hr 0.000 AC/hr
Above Grade Volume: X 48,666 Cu.ft. X 48,666 Cu.ft.
9,671 Cu.ft./hr 0 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 161 CFM 0 CFM
Total Building Ventilation: 160 CFM 160 CFM
—System 1—
Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 90.72 = (1.10 X 0.970 X 85.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.280 AC/hr (227 CFM), Construction: Average
Summer Infiltration Specified: 0.150 AC/hr (122 CFM), Construction: Average
C:\ ...\3797 Lakeside Ct, Eagan.rh9
Thursday, June 11, 2020, 6:21 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Mike's Custom Mechanical, Inc l 3797 Lakeside et, Eagan
Dayton. MN 55327 9 Page 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
custom glass: Glazing -custom home
SHGC 0.28
custom glass: Glazing -custom home
SHGC 0.27
custom glass: Glazing -custom home
SHGC 0.25
custom glass: Glazing -custom home
SHGC 0.27
custom glass: Glazing -custom home
SHGC 0.28
custom glass: Glazing -custom home
SHGC 0.29
custom glass: Glazing -custom home
SHGC 0.3
11 P: Door -Metal - Polyurethan:
norton walls: Wall -Frame, Custom,
cavity no board insluation siding
norton basement2: Wall -Basement,
brink stone or concrete wall,
floor in 2x6 cavity, core, no
interior finish, wood studs,
b-49: Roof/Ceiling-Under Attic with
Floor (also use for Knee Walls
Ceilings), Custom, roof/ceiling-under
insulation on attic floor, vented
barrier, dark asphault shingles
glass,
glass,
glass,
glass,
glass,
glass,
glass,
- = -
R-20 i
u-value 0.22, 277 5,184 0 5,073 5,073
u-value 0.23, 42 821 0 340 340
u-value 0.21, 42 750 0 314 314
u-value 0.22, 25 468 0 199 199
u-value 0.2, 163 2,772 0 2,499 2,499
u-value 0.22, 185 3,460 0 3,182 3,182
u-value 0.22, 25 468 0 214 214
21 518 0 146 146
sulation in 2x6 4312.5 23,828 0 3,728 3,728
wood studs
eight inches 1170 6,862 0 695 695
finish
Custom,
framing
board insulation,
2' floor depth
Insulation
and Partition
attic, no
or dark
sulation
slab, any
insulation
withrrnblill to
plus
on Attic 1844.8 3,137 0 1,770 1,770
attic with
radiant
metal, tar and
thickness, 2 1558.2 3,577 0 0 0
below floor,
gravel or membrane, r 9 i
21A-20: Floor -Basement, oncrete
or more feet below grade, no
any floor cover, shortest side of floorslab is20' wide __.._..._.
Subtotals for structure: 51,845 0 18,160 18,160
People: 6 1,200 1,380 2,580
Equipment: 1,349 4,948 6,297
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 161, Summer CFM: 0 14,621 0 0 0
Ventilation: Winter CFM: 160, Summer CFM: 160 5,806 2,482 2,220 4,702
Humidification Minter) 21.60 gal/day ;.... 7,922 0. 0...... 0....
Total Building Load Totals: 80,193 5,031 26,708 31,739
Check Figures
Total Building Supply CFM: 1,147 CFM Per Square ft.: 0.180
Square ft. of Room Area: 4488 sq ft Square ft. Per Ton: 2,412
Volume (ft3): 48,666
Building Loads
Total Heating Required Including Ventilation Air. 80,193 Btuh 80.193 MBH
Total Sensible Gain: 26,708 Btuh 84 %
Total Latent Gain: 5,031 Btuh 16 %
Total Cooling Required Including Ventilation Air. 31,739 Btuh 2.64 Tons (Based On Sensible + Latent)
Notes �.
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\3797 Lakeside Ct, Eagan.rh9
Thursday, June 11, 2020, 6:21 AM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Mike's Custom Mechanical, Inc
IC 3797 Lakeside Ct, Eagan
Dayton, MN 55327 Page 34
System 1 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Clg Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
-Zone 1-
1 Family Room 300 5,416 81 1-4 483 899 200 42 42
2 Gasmes And . 420 3,668 55 1-4 283 528 200 25 25
Stairwell
3 Bed 5 195 3,201 48 1-4 226 421 0 20 20
4 Basement Bath 105 787 12 1-4 21 39 0 2 2
5 Mech Room 195 3,572 54 1-4 112 208 0 10 10
6 Exercise 168 2,463 37 1-4 81 151 0 7 7
Zone 1 subtotal 1,383 19,107 286 2,246 400 105 105
-Zone 2-
7 Pantry 41 1,101 16 1-4 96 179 0 8 8
8 Mud Room 94 2,033 30 1-4 220 409 0 19 19
9 Kitchen 231 2,243 34 3-5 589 5,147 1,549 241 241
10 Main Stairwell 206 4,379 66 1-6 471 1,974 0 92 92
11 Greatroom 322 4,316 65 1-6 541 2,267 400 106 106
12 Study 155 2,447 37 1-5 596 1,735 0 81 81
13 Powder Bath 88 577 9 1-4 131 244 0 11 11
14 Dining 155 2,368 35 1-6 467 1,957 200 92 92
15 Ent!), 101 748 11 1-4 326 608 0 28 28
Zone 2 subtotal 1,394 20,212 303 14,520 2,149 680 680
-Zone 3-
16 Bedroom 2 169 2,831 42 1-4 479 893 0 42 42
17 Jack N Jill Bath 195 1,564 23 1-4 217 404 0 19 19
18 Bedroom 3 156 2,816 42 1-5 615 1,791 0 84 84
19 Bedroom 4 192 2,225 33 1-5 595 1,733 0 81 81
20 Master Bath And 272 3,895 58 1-5 581 1,692 0 79 79
Closet
21 3/4 Bath 2nd Floor 96 179 3 1-4 54 101 0 5 5
22 Laundry Room 119 242 4 1-4 330 615 0 29 29
23 Owners Suite 288 3,889 58 1-4 641 1,194 0 56 56
24 Loft And Stairwell 224 5,640 84 2-5 629 3,662 0 172 172
Zone 3 subtotal 1,711 23,281 349 12,085 0 566 566
Zono 1
25 Rim Joist 900
1,884 28 1-4 112 208 0 10 10
Basement To Main
26 Rim Joist Main To 992
1,982 30 1-4 117 218 0 10 10
Second
Zone 4 subtotal 1,892
3 866 58 426 0 20 20
Ventilation 5,80 subtract from floor area 2,220 2,482
Humidification 7,_922
System 1 total 6,380 80E193 996 26,708 5,031 1,147 1,147
System 1 Main Trunk Size: 12x17 in.
Velocity: 810 ft./min
Loss per 100 ft.: 0.092 in.wg
Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains
at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended
to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which
the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the "Average Load
Procedure + Excursion" method.
Cooling System Summary ,
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 2.64 84% / 16% 26,708 5,031 31,739
C:\ ...\3797 Lakeside Ct, Eagan.rh9
Thursday, June 11, 2020, 6:21 AM
• r
Rhvac - Residential & Light Commercial HVAC Loads
Mike's Custom Mechanical, IncIli)
Dayton. MN 55327
Elite Software Development, Inc.
3797 Lakeside Ct, Eagan
Page 35
System 1 Room Load Summary (cont'd)
Cooling Sensible/Latent
Tons Split
Sensible
Btuh
Latent Total
Btuh Btuh
Equipment Data
Heating System
Type: Natural Gas Furnace
Model:
Indoor Model:
Brand:
Efficiency: 0 AFUE
Sound: 0
Capacity: 0 Btuh
Sensible Capacity: n/a
Latent Capacity: n/a
Cooling System
Standard Air Conditioner
0 SEER
0
0 Btuh
0 Btuh
0 Btuh
C:\ ...\3797 Lakeside Ct, Eagan.rh9
Thursday, June 11, 2020, 6:21 AM
Ventilation, Makeup and Combustion Air Calculations
• Submittal Form For New Dwellings
Site arkbess
Contractor
3-7/1 &Ac i&L04_,Skrti fie cilatue4rryeted
c .
1
Ventilation Quantity
(Determine quantity by using Table N1109.2 or Equation 11-1)
Square feet (Candi area tnduding
aaavmaet—finished o unfinished)
L42.1
Total required' ve„taatmn
�'30
r
Number of bedrooms
3
Conffma uaverRflation
(/�
Directions -Determine the total and continuous ventilation rate by either using Table N1104.2 orequodon 111.
The table and equaton are below.
Table N11.04 2 '
Total and Continuous Ventilation Rates tm dm) •
Number of Bedrooms .
1
2 •
3
4 '5
6
Cpnd)tioned.space in
sq. ft.)
Total/. .
continuous
Total/
continuous
Total/
continuous
Total/
continuous
Total/
' continuous
Total/
continuous
1000-1500
-60/40
75/40
90/45
105/53
120/60
135/68
1501-20 0
70/40
85/43
100/50
115/58
130/65
145/73
2001-2500
80/40
95/48
110/55
125/63
140/70
155/78
2501-3000
90/45
105/$_3 .
120/60
135/68
150/75
165/83
3001-3500
100/50
115/58 '
130/65 '
145/73
160/80
175/88
3501-4000
110/55
125/63
140/70
155/78
170/85 .
185/93.
4001-4500
120/60
.135/68
150/75 _
165/83-- -
180/90
195/98
4501-5000 •
130/65
145/73
160/80
175/88
190/95
205/103 '
5001-5500
140/70
155/78
170/85
185/93
200/100
'
215/108
5501-6000
150/75
165/8a
180/90
195/98
210/105
225/113
Equation 11-1
(0.02 x square feet of conditioned space) + I15 x (number of bedrooms + 1)] Totatventtlatlon rate (cfm)
Conditioned space includes the basement
1 If conditioned space exceeds 6000 sq. ' it or there ere nq e_ tlian 6 bedrooms, use
Bquetion'11-1 froinSedioaN11042 to calculate total ventilation rate.
Total ventilation —The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,
for each one -hour period according to the above table or equation. For heat recovery ventilators (HRV) and energy recovery ventila-
tors (ERV) the average hourly ventilation capadty must be determined In consideration of any reduction of exhaust or out outdoor
air intake, or both, for defrost or other equipment cycling.
Continuous ventilation - A minimum of 50 percent of the total ventilation rate, but not less than 44 cfm, shall be provided, on a con-
tinuous rate average for each one -hour period. The portion of the mechanical venbilation system intended to be continuous may
have automatic cycling controls providing the average flow rate for each hour is met
Page 1 of 6
Section B
Ventilation Method .
• lamas either balanced ar embattle only)
NI Balanced, HRV (Heat Recovery Ventilator) or E W (Enemy Rem-
0 Briniest only
ery Venttatarl-cfm dentin law must not exceed continuous vents-
Continuous Fan rottenly' cfm
Winn rating by more than 100%.
-
Law the:
96
High cfm
', ;
Continuous fan rating in cfni.(tapacity mast not exceed
_
14,1
_ continuous ventllation rating by more than 100%)
Directions -Choose the method of ventilation, balanced or exhaust only. Balanced ventilation systems are typicbr(ly ?JRV or ERV'5
Enter tine !ow and high elm amounts. Low cfm airflow must be equal to or greater than the squired continuous ventilation rate and
less than 100% greater than the Continuous rate. (For Instance, if the law cfm is 40 cfm,-the ventilation fan must not exceed SO cfm_)
Automatic controls may allow the use of a largerfan that is operated a percentage of each hour.
Section C
Ventilation Fan Schedule
Description
M) 9
Location
likkec (-Do
Continuous
Intermittent
3 /86 .
Directions -The ventilation fan schedule should describe what the fan ks far, the location, cfm, and whether It is used for continuous
arhrtermittent ventilation. The fan that is chose for continuous ventilation must he equal to or greater than the/ow cfrn air rating
and lets than 100% greaizr than the continuous rates (far instance, the low cfrn Is 40 cfm, the continuous ventilation fan must not
exceed 80 cfm.) Automatic controls may allow. the use of a larger fan that Is operated a percentage of each hour; .
Section D
Ventilation Controls
• (describe operation and antral of the continuous ous and intermlttentventilation)
42A tea.
Directions - Describe the operation of the ventilation system. There should be adequate detail for plan reviewers andInspectors to verb desk and
installation compliance Related trades also need adequate detail forplacement of controls and proper operation tithe bulIdtng ventilation. If
exhaust faits are used forburdding ventilation, describe the aperatfon andlocotion of any controls, indicators and legends. Ilan ERV orHRVlsto be
lnstalle4 describe how it will beOstalled. if it will be connected and ►nterfaced with the air handling equipment please describe such corutertians as
detailed in the manufactures' lnsmllalion hnstni lions. if the installation las rualans regbhfre orrecommend the equipmentto be 6rtLdu.kud with the
airbandring equipment for proper operation, such interconnection shall be made and described
Make-up air (vv ‘ i f., ,•'
Passive (determined from calculations kern Table's 1 ,)
Pawared (determined from eaiatlatins s from Table SOL3i1)
Interlocked vdth exhaust device (determined frare caicu)ation from Table5013.1)
Other, describe:
Location of duct or system ventilation make-up air: Betermined from matte -up air opening table
' Cam I l Sae and type (round, rectangular, fix or right)
(NB means not required) -
Page 2 of 6
N
d
N
M
M
N
•
N
81
N
M
N
M
N
M
N
N.
N
N
M
M
Aa
-N
N
M.
Ad
N
M
td
61
M
N
N
u
M
m
N'
M
N
M'
N
NI
N
m
N
e
N
m
N
u
N
tt
N
n
m A.Usethis coloranif there are other then fan -assisted o a y dgas orO17Cpp .
d B.Use this coinnm if there is one fan -assisted appliance pet venting system. Other than atmospherically vented appliances snag also bainoltded.
C.Use this column ifthere Is one atmasphedcally vented (other team fan-esslited) gas or mll applancepemendag syst m or one solid ihel appliance.
N D.Use this column if there are multiple atmospherically vented gas or oil appiiuncer using a common vent as if there am atmospherically seated gas or oil
61
• appliances end solid fuel appliances.
TABLE 50't.4.1
0 DETERMINE MAKEUP AIR QUANTITY FOR E GIAUSTAPPLIANCES IN DWELLING UNITS
-
.
ONE OR MULTIPLE POWER
VENT OR DIRECT VENT
APPLIANCES OR H0
COMBUSTION APPUANCESA'
ONE OR MULTIPLE FAN-
ASSISTED APPLIANCES
AND POWER VENT OR
D6CTYENT APPLIANCES'
`
ONE ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCE 0R ONE
SOLID FUEL APPLIANCE°
MULTIPLE APPLIANCES THAT
ARE ATMOSPHERICALLY
VENTED GAS DR OIL
APPUANCES OR SOU° FUEL
APPLIANCES°
to Estimate House 1.1M:ration .
1. Use the Appropriate Column
a) pressure factor0.15
•
0.09
0.06
0.03.
-
b) =Maned floor
area (si)
—
40
—
—
(iecluding m%finishedbasements)
Estimated $Ouse•
%QttBtiott (CiIIt).
[la x lb] -
ff,,,Z'] `-�
1.C(J(,.(. I
—
.
—
2. Eahauat Capacity
a) clothes dryer135
135
135
.135
'
b) 80% of largest
exha rating (dm):
�I /�
`7
—
—
--
(not applicable if recirculating
system orif powered makeup afr is electdca lyinterlocked and matched to exhaust)
c) SO% of next largest
eithanstxating (te):
—•
--
net
(not appticableirecimulating system orifpowered makeup airis electrically intetioelred and matched to exhaust)
. TotaLHxhaust Capacity
(dm):
(2a-W.13+2c]
— 37 5
—
—
—
.
3. Makeup AirRequirement . .
•
. .
a) Total Pxbeust
Capacity
ab
�j <_
— "' J
•
—
b) Estimatedliousa
Infiltration (from
above)
-
j n �'
%
—
—
—
��
Makeup Aar
Quality -(col):
(3a-3b]
..L....L..-7
- .2.57t .+
—
—
(if value is negative, no
-
makeup air is needed •
•
Table 501.4.2.
4. For betaken, Air Opening Sizing, teferio
38
2015 MINNESOTA MECHANICAL CODE
EXHAUST SYSTEMS
TABLE 501.4.2
NG TABLE FOR NEW AND EXISTING DWELLING UNITS
TYPE OF OPENING
OR SYSTEM
,•L•,• ••. _ _ -
ONE OR MULTIPLE POWER
VENT OR DIRECT VENT
APPUANCES OR NO
CONISUSTION .
ApPLIANCES°
ONE OR MULTIPLE FAN-
ASSISTEDAPPUANCES
AND POWER VENT OR
DIRECT C°
APPLIANES
ONE
ATMOSPHERICALLY
VENTED GASOR OIL
APPLIANCE OR ONE
SOLID FUEL
APPLIANCE°
MULTIPLE APPUANCES
THAT
ARE ATMOSPHERICALLY
VENTED GAS OR OIL
APOR PLIANCES
FUEL APPUANCES°
PASSIVE MAKEUP AIR
IAM °
(aim)
(efm) .
(clm)
(afm)
(lnehes)
Passive opening
1-36
1-22
. 1-15
1-9
3
Passive opening
37-66
' 23-41
16-28
10-17
4
Peeve
67-109 •
42-66
29-46
18-28
5
opening
Passive opening
- 110-163
67-100.
47-69
29-42
6
Passive opening
164-232
101-143
70-99
. 43-61
7
233-317
144-195
100-135
62-83
8
Passive opening
Passive opening
with motorized
_
318-419
196-258
136-179
84-110
.
9
420-539
259-332
ISO-230
111-142
10
Pave op
• with motorized
damper
Passive opening
with motorized
� 540-6'79
333-419
231-290
'
143-179
11
damper
Powered makeup
> 679
> 419
> 290
> 179
Prot
aqeble
pp
yid gas Oil appJiaetee3 arlf heza a a.)no C,O�i�nbt t1OR tip m
A.Use this tnlnmu theme ate OW than C-a&S d Or Ser venting ti� Q� $ ap " ce may also ba led le
B. T>m this caivam if theseis one fmQ-asaistad cq�gGanuperaroma slid final
C. Use this adman if there is one vented (other then fan-aassisted) gas or ail appliance 1 venting sysiam apple. N
atmospherically atlno d a common vent at if there are atmlosphesiaany vented gas or oil
1.1
D. Use this column if mere are multiple Y vented gas or oil appliances rasing
. appliances and solid fuel appliances.
E. An equivalent length of 100 fed of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet fee each 90-degree elbow to14
della:mine the remaining length of airiest duct allowable. N
P. If Seaga duceis ased, increase the duct dianieterby one inch. Flexible duct shall be st et ]ied with minimal sags. re
0. Barometric dampers are profited inpassive rnalanspair openings when any atmosphedcally vented appliance is Installed. m
13. Powered makeup air shall be electrically interlocked with the largest eshmrst system
37
- 2015 MINNESOTA MECHANICAL CODE
Directions -The Minnesota Fuel Gas Code method to cakrdate to size of a required combustion air opener is called the Known Air
Infiltration Rate Method. For new corrstruttfon, 4b of step 4 Is required to be filled out.
tr4CAppendix E. Worksheet E1
Residential Combustion Air Calculation Method
(for Furnace, Boller, and/or Water Heater in the SanteSpace)
c"' '
Step 1:CAmplebevented combUstkmappliancahlfoi,umilwI.
Fan Assisd iced Vent input Btu/hr I.:7
__D _
ruStc
or Power Vent �e r 14 ,
Water Heater: •
Draft Hood Fan Assisted Direct Vent input etti/hr
_
or Power Vent
Step 2:Calculate the volume af the Cuxnbustton AppUance Space (CAS) containing combustion appliances.
The CAS b dudes all spacesconnected to one another by code compliant openings. CAS volume:
fe
LxWxH L W H
Step 3: DetermineAtrchanges per Hour (ACH)1
Default ACH values have been hscorporated into Table E 1 for use with Method 4b (iCAIR Method).
If the year of construcrian orACHis not Imown, use method 4a (Standard Method).
Step 4: Deterndne Required Volume forCombustlon Mr. (DO NOT COUNT DIRECT VENTAPPUANCES)
4a.Standard Method
Total Btu/hrinput ofall combustion appliances Input Btu/hr
fe
Use Standard Method column In Table E-1 tofind Total Required TRV: fe
.
Volume (IRA
If CAS Volume (from Step 2) fsgreater'him TRV then no outdoor opener are needed.
If CAS Vohmse(fromStep 2) IsressthunTRY then go to STEP S.
4b. Known Mr htfiitration Rabe (CAIR) Method (DO NOT COUNT DIRECT VENT APPLIANCES)
Total Btu/hrinput af ail fan -assisted and power yard appliances Input Btu/hr
•
Use Fan -Assisted Appliances column &Table E1to fhd RVFA: - fta
Required Volume Fan Asked (RVFA
Total Btu/hrInput of all Natural draft appUances input Btu/hr
Use Natural draft Appliances column In Table Ei to find RVNFA: fe
Required Volume Natural draft appliances (RVNi A)
Total RegWred Volume (TRV) =RVFA + iWNDA TRV = + = TRV
If CAS Volume Morn Step 2)fsgreaterthanTRV then no outdoor openings are needed.
If CAS Volume (from Step Waist then go to STEP-S.
Step S:Calcolatethe ratio of availatdeinteriorvtdume to the total required volume.
Ratio=CAS Volsxne (horn Step 2) divided byTRV (from Step 4a or Step 4b)
Ratio = / _
Step 6: Calculate Reduction Factor(RF).
RF=1atnusRatio RF=1_ _ -
Step 7: Calculate single outdoor opeoingas ifalt combustion air Is from outside.
Total Btu/hrInput dell Combustion AppfaruesCn the same CAS Input Btu/hr
(EXCEPT DIRECT VENT)
Combustion Air opening Area (CADA): i
Total rdrvrdedby3000 Btulhr perina CADA= /3000lttu/hr per �= in
Step tC Calculate IWIrthnum CADA
MUNmum CAQA=CADAmuftipitedby RF MlnJmum CADA= x = in1
Step 9: Calculate Combustion Air Opening Diameter(CAOD)
the square root ofMhttmumCAOA CAOD=1.134 Minimum CAOAa in. diameter
CAdo=1.13muItfpUedby
go up one Inch inshe li using ilex duct
1 If dashed, ACH an be determined using ASHRAE caiwlatian or blower door test- Follow procedures in Section
G304.
Page 5 of 6
•
Residential Combustion air
IFGC Appendix E, Table E-1
(Required Interior Volume Based on Input Rating of Appliance)
Input Rating
(8tu/hr)
Standard Method
Known Air Infiltration Rate (KAMR) Method (cu ft)
Fan Assisted or Power Vent
Natural Draft
1994 to present
Pre-1994
1994 to present
Pre-1994
5,000
250
375
188
525
263
10,000
500
750
375
1,050
525
15,000
750
1,125
563
1,575
788
•
20,000
1,000
1,500
750
2,100
1,050
25,000
1,250
1,875
938
2,625
1,313
30,000
1,500 -
2,250
1,125
3,150
1,575
35,000
1,750
2,625
1,313
3,675
1,838
40,000
2,000
3,00000
4,200
2,100
45,000
2,250
3,375
1,688
4,725 .
2,363
50,000
2,500
3,750
1,675.
5,250
2,625
55,000 •
2,750 "
4,125
2,063
.
5,775
2,888
60,000
3,000
4,500
2,250
6,300
3,150
65,000
3,250
4,875
2,438
6,825
3,413
70,000
3,500
5,250 '
2,625
7,350
3,675
75,000
3,750
5,625
2,813
7,875
3,938
80,000
4,000
6,000
3,000
8,400
4,200
85,000
4,250
6,375
3,188
8,925
4,463
J
90,000
•
4,500
6,750
3,375
9,450
4,725
95,000
4,750
7,125
3,563
9,975
4,988
100,000
5,000
7,500
3,750
10,500
5,250
105,000
5,250
7,875
3,938
11,025
5,513
,
110,000
5,500
8,250
4,125
11,550 .
5,775
115,000
5,750
8.625
4,313
12,075
6,038
120,000
6,000
9.000
4,500
12,600
6,300
125,000
6,250
9,375
4,688
13,125
6,563
130,000
6,500
9,750
4,875
13,650
6,825
135,000
6,750
10,125
5,063
14,175
7,088
140,000
7,000
10,500
5,250
14,700
7,350
145,000
7,250
10,875
5,438
'
15,225
7,613
150,000
7,500
11,250
5,625
15,750
7,875
155,000
7,750
11,625
5,813
16,275
8,138
160,000
8,000
12,000
6,000
16,800
8,400
165,040
8,250
_12,375
6,188
17,325
8,663
170,000
8,500
12,750
6,375
17,850
8,925
175,000
8,750
13,125
6,563
18,375
9,188
180,000
9,000
13,500
6,750
18,900
9,450
185,000
9,250
13,875
6,938
_ 19,425
9,713
190,000
9,500
14,250
7,125
19,950
9,975
195,000
9;750
.14,625
7,313
20,475
10,238
200,000
10,000
15,000
7,500
21,000
10,500
205,000
10,250
15,375
7,688
21,525
10,783
210,000
10,500
15,750
7,875
22,050
11,025
215,000
10,750
16,125 _
8,063
22,5'75
11,288
220,000
11,000
16,500
8,250
23,100
11,550
225,000
11,250
16,875
8,438
23,625
11,813
230,000
11,500
17,250
8,625
24,150
12,075
L The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table Is
0.20 ACN.
2. This section of the table Is to be used for dwellings constructed prior to 1994. The default KAIR used In this sexton of the table is 0.40 ACIi.
Page 6 of 6
City Inspection Dept. Copy
City Forester Copy
Applicant/Builder Copy
EAGAN
INDIVIDUAL RESIDENTIAL LOT
TREE PRESERVATION PLAN SUMMARY
CITY OF EAGAN FORESTRY DIVISION
651-675-5300
(BUILDER, PLEASE READ ATTACHMENTS)
Development Lakeside of Eagan
Lot Number
Address
Builder
2
3797 Lakeside Ct
Block Number 1
Norton Homes
Phone Number: 763-559-2991
Contact: Pat Hiller
Tree Protection Requirements:
X Tree Protection Fencing Installed on Site (orange 4' poly fence)
X Oak Tree Pruning (Immediately seal wounds during April 1 to July 31)
Therapeutic Pruning Required
Retaining Wall To Be Installed
Other:
Replacement Trees:
X Not Required
As Follows:
Attachments:
X Yes (Refer to attached documents for details)
No
Additional Notes:
EAGAN FORESTRY DI ISION
DATE: 3/23/2020
NOTES:
i
mcn
A1A2![1S A0 aLVJId1.LNAJ
li
1.41".
I LAKESIDE COURT
iti
ii ill ; I
is 1 ., *s..r, ii$iA
'Illl"A 14111139
"�-aA
:fit Ott036
119
�`s�e lied
J
TREE PRESERVATION PLAN REVIEW — INDIVIDUAL LOT
EAGAN
Date Building Permit Application Received 3/16/2020
Development Lakeside of Eagan
Site Address 3797 Lakeside Ct
Lot 2
Block 1
Builder Norton Homes
Telephone 763-559-2991
Property/Lot Owner Name -
Telephone -
Contact Pat Hiller
E-mail
E-mail -
Office Plan Review — Date 3/20/2020 Notes All significant trees in house construction
area were removed with initial development. Development only had 39.1% removal. No mitigation
is required for any lot, unless there is additional tree removal.
Tree Preservation Data Original Plan Revised Plan
Total Significant Woodland Area sq. ft sq. ft
Total Significant Trees
Woodland To Be Removed sq. ft sq. ft
Trees To Be Removed
Allowable Woodland Removal (20%) sq. ft sq. ft
Allowable Tree Removal (20%)
Required Mitigation YES (or) NO
Calculated Mitigation Amounts
Original Plan - Category A Category B Category C
Revised Plan - Category A Category B Category C
Site Inspection — Date 3/23/2020
Notes 1) House Location is staked 2) Original silt fence / tree
protection fencing is still up but. should be reset.
G:\Forestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docc
Original Tree Preservation Plan Approved — Date 3/23/2020
Forwarded to Inspections — Date 3/23/2020
Discussion/Meetings with Builder/Owner - Notes
Revised Tree Preservation Plan Approved — Date By
Forwarded to Inspections — Date By
Additional Field Inspections
Date Notes
Date Notes
Date Notes
Date Notes
G:\ orestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docx
Was the approved Tree Preservation Plan followed? YES (or) NO
If no, was additional mitigation required? YES (or) NO (If yes, describe additional mitigation below)
Final Site Inspection — Date Notes
Additional Notes and/or aerial photo image
(insert aerial image or draw map of site)
G:\Forestry\TreePreservatlon\Tree Preservation Plan Review - Individual Lot.docx
02017 Westwood Professional Services, Ine.
Drainage & Utility
Area = 36, 785.31 sf
rrr—
Drainage &
/1\
I \
I
I \
\B L 0
I\
\ \
\ I
\ I
\\ 1 Drainage & Utility
/ \\\\Area = 58,851.12 sf
\ `.
Utility
•
•
C K
/
•
•
•
•
•
•
•
\
\
Drainage & Utility 11
Area = 36, 653. 901 1 sf
I /
/
I /
1 /
Easement--4,/
•
•
•
1
Lot 4
\ 48,142.90 sf
/ \ \
\ 4
Lot 3 \ \
45,226.31 sf\ \
\ 3 \
1 12,06` 92 sf
Drainage & Utility ( 1 \
Area = 23,830.83 sf 1 Lot 1 O
30, 368.83 sf —
--Drainage & Utility Easement i
\
sf
L
2
Lot 2
69,157. 12
N
IA/r-^t•/'1TT
YY L_.ivV / /
C,/n A n
1 \ V/-1 L 1
Total Boundary =
204,963.072 sf or
4.705 acres
a'
i
Westwood
dim 0162)1074,10 /NE MEnwanw
►� IEE2)0874t22 Erahune.1161 YEY
?m (OM NtNW-•---*-MM
��AEW rAni�
Lakeside of
Eagan
Eagan, Minnesota
80'
160'
Sheet 1 OF 1
Date 1/16/2018
0012565APF01.dwg
Area Map
i
\
S754 5364 r
"
5391
512
5441
3442-
5440.
5377
5376
5375.
5119
5116�
5373--,
5125
5372
-- 5121-
5124
51070
5112
5361 51 t`t_
3117 .\
5115
5114
5120
511
5122
5112
5111
�51 )
.:r.� �-s"'��.• 4L:212—.Lr~i.--ii�iy,.--LU1*: -.I ` 7.5 Ki���r
i1t aiiat MMIN M1■
�O111ii4711 ��u�/�' �oim 1�r _._.i,6 0mr6r���
' ��IN�16•ZSLR9/ur.7c.�iZT�'�---1:1_i le
I �
mum-
1 5199
52
52
4
silt'
6I h,
�4
5p7o 5oafi 4
5071
pson
SQ;S9 e, 5069
5075
5076
i\ I!
\ :)7,
5059
5034
5056
5061
5077
Im„ 441 5037
5046
5046
5026
3025
5016
b'0
O
oa i;
`, gip
TREE
PROTECTION
FENCE`
TREE
PROTE
FENCE
5297
5330
4
5793
5216
DD
1
DD
PROPERTY LEGAL:
LOT SURVEY CHECKLIST FOR RESIDENTIAL
BUILDING PERMIT APPLICATION
Lot 2, Block 1, Lakeside of Eagan
DATE OF SURVEY: 3/26/2020
LATEST REVISION:
-7' 7 L �//s, �de C .
c
co
O Z Q DOCUMENT STANDARDS
O 0 ❑ • Registered Land Surveyor signature and company
✓❑ ❑ ❑ • Building Permit Applicant
O 0 0 • Legal description
0 0 ❑ • Address
O 0 0 • North arrow and scale
O 0 0 • House type (rambler, walkout, split w/o, split entry, lookout, etc.)
0 ❑ 0 • Directional drainage arrows with slope/gradient %
O 0 0 • Proposed/existing sewer and water services & invert elevation
0 ❑ ❑ • Street name
❑✓ ❑ ❑ • Driveway (grade & width - in R/W and back of curb, 22' max.)
✓❑ 0 ❑ • Lot Square Footage
0 ❑ 0 • Lot Coverage
✓❑ ❑ ❑
❑✓ ❑ ❑
❑✓ ❑ ❑
❑✓ ❑ ❑
O ❑ ❑
EOM
El ❑ ❑
O ❑❑
a❑❑
✓❑ ❑ ❑
O ❑❑
✓❑ ❑ ❑
No
MEM
O ❑ 0
E
✓ � C
ELEVATIONS
Existing
• Property comers
• Top of curb at the driveway and property line extensions
• Elevations of any existing adjacent homes
• Adequate footing depth of structures due to adjacent utility trenches
• Waterways (pond, stream, etc.)
Proposed,
• Garage floor
• Basement floor
• Lowest exposed elevation (walkout/window)
• Property comers
• Front and rear of home at the foundation
• PRV Required
PONDING AREA (if applicable)
• Easement line
• NWL
• HWL
• Pond # designation
• Emergency Overflow Elevation
• Pond/Wetland buffer delineation
• Shoreland Zoning Overlay District
• Conservation Easements
DIMENSIONS
• Lot lines/Bearings & dimensions
• Right-of-way and street width (to back of curb)
• Proposed home dimensions including any proposed decks, overhangs greater than 2', porches, etc.
(i.e. all structures requiring permanent footings)
• Show all easements of record and any City utilities within those easements
• Setbacks of proposed structure and sideyard setback of adjacent existing structures
• Retaining wall requirements:
Reviewed By: Dave Westermayer
Date 4/1 /2020
G:/1 Engineering/Forms/Cert. of Survey Checklist Fillable 6-28-19
S89°56'08"W
39.66
S81°34'14"E 161.08
LOT 1
50 25 0 25 50
SCALE IN FEET
100
Rat
\ BLOCK l
\ LOT 2
EASEMENT PER
DOC NO 3169807
--EDGE OF WATER PER PLAN ---
RETLAND JP43.2
HWL = 695.70
OUTLET 895.0
\ \/
SI31a34t14"E/ 19,08
EDGE OF WATER PER PLAN
WETLAND JP43.3
HWL-898.1
OUTLET.897.5
II---'- EAG�1- GLNL�,tttiNu E-,._.r
_
898.9
3:1 Maximum Slopes /
or i :_'raining Wall Witi /
®H Fiequ,red toT
N
WET
899.3
3a
NbsCaw =b2i
901.10 33
EXISTING LO
CF - 906.0
TF - 907.3
LO - 901.8
BF - 898.6
a 901.0
904.3
/
BY:.
DATE:
BUILDING INSPiCTiONS DIVIS;Dial
/a 906.3
L 9Kes', c,16-
LOT 4
• 90s.8
9085
0)
05 92 )'P+a
_ y .` ! - ik
11,1
\ 7/_t/A 1
\
\
\
\
\
906.8
w 3LAKESIDE COURT
, q-
903.5
DESCRIPTION OF PROPERTY SURVEYED
Lot 2, Block I, LAKESIDE OF EAGAN, according to the recorded plat thereof, Dakota Couty, Minnesota.
STANDARD NOTES
I) Site Address: 3797 Lakeside Cant, Eagan, Minnesota 55123
2) A title opinion was not furnished to the surveyor as pan of this survey. Only easements per the rewN d plat are shown unless otherwise denoted hereon.
3) Benchmark: TNII fru La 1 & 2, Block I, LAKESIDE OF EGAN -906.27 Feet
4) Principal Structure Swbarlu-Front: 30 fen
- Side: 6 feet Living, 5 feet Garage
Please note that the general restrictions for the subject property may have been amended through a city process We could be unaware of such amendments if they
are in a recorded document provided to us. We recommend that a zoning letter be obtained from the Zoning Administrator for the current restrictions for this
We have not received the current awing classification and building setback requirements flan the insurer.
5) Utmder We have shown the location of utilities on the surveyed property by observed evidence only. There may be underground utilities encumbering the subject
property we are unaware. Please note that we have not placed a Gopher State Onc Call for this survey. There may or may not be underground utilities in the
mapped area, therefore extreme caution must he exercise before any excavation takes place on or near this site. Before digging, you are required by law to notify
Gopher State One Call at least 48 hours in advance at 651i454.6002.
6) Grading must maintain a minimum 2% slope gradient to accommodate positive drainage.
7) MI set offset irons are measured to hundredths of a fat and can be used M benchmarks for construction
8) The proposed driveway shown is conceptual only and does not putpon to show exactly how the driveway shall he built
9) Proposed grades shown adjacent to building foundation refers to top of black dirt
10) Verily unitary service invert prim to any concrete work.
iNST2tER E
U.
CONTROL.
Development Plan Data - WO
Garage Floor Ekvarion
Basement Floor Elevation
Proposed Elevations - LO
Proposed Garage Floor Elevation
Proposed Top of Foundation Elevens.
Proposed Inokou1 Opening Elevation
Proposed Basement Flom Flevmion
Building Cover
La Area - 69,158 S.F.
Upland Area - 43,831 S.F.
Pond Area - 25,307 S.F.
House Area - 2,215 S.F
Cos erage- 5.I%
.91010 Step Drip)
.903.5
-907.7 (1' Drop)
= 909.0
= 903.5
Offset Irons
(He,*N4m are to the tap of pipe)
OS a1-901.28 OS 02-907.57
OS ad- 901.20 OS 83- 902.05
Bearkps are based on the Henneph County
Coordinate System (NOD 83 - 1986 adj.)
20 10 0 10 20
SCALE IN FEET
SURVEY LEGEND
40
O• CAST IRON MONUMENT
• CATCH BASIN
d FLARED END SECTION
DO GATE VALVE
▪ GUY WIRE
Vr HYDRANT
O SURVEY MONUMENT SET
• SURVEY MONUMENT FOUND
Ah SURVEY CONTROL POINT
M LIGHT POLE
Ma POWER POLE
)( SANITARY MANHOLE
Q SANITARY CLEANOUT
SIGN
zz.5 GROUND ELEVATION
® STORM DRAIN
® STORM MANHOLE
D YARD LIGHT
® A/C UNIT
WELL
WOE WALKOUT ELEVATION
FEE FIRST FLOOR ELEVATION
GEE GARAGE FLOOR ELEVATION
TOE TOP OF FOUNDATION ELEV
LOE LOWEST OPENING ELEV.
C CABLE TV PEDESTAL
m ELECTRIC TRANSFORMER
m ELECTRIC MANHOLE
O ELECTRIC METER
O GAS METER
O GAS VALVE
® HAND HOLE
SOIL BORING
�3 TREE CONIFEROUS
o TREE DECIDUOUS
m TELEPHONE MANHOLE
M TELEPHONE PEDESTAL
TRAFFIC SIGNAL
O UTILITY MANHOLE
61 UTILITY PEDESTAL
BITUMINOUS
- BUILDING SETBACK LINE
- OTV- CABLE TV
CONCRETE CURB
(CONCRETE
'Pao _ -- CONTOUR EXISTING
-�� CONTOUR PROPOSED
GUARD RAIL
- 0T - DRAIN TILE
- DC- ELECTRIC UNDERGROUND
-a-a- FENCE
- f0 - FIBER OPTIC UNDERGROUND
- OAS- GAS UNDERGROUND
- old- OVERHEAD UTILITY
+HFHH41) 111F RAILROAD TRACKS
-a- SANITARY SEWER
STORM SEWER
- TELEPHONE UNDERGROUND
- tat- UTILITY UNDERGROUND
- I - WATERMAIN
FIELD CREW
NO.
BY
DATE
REVIBpN
00 DY
JPR
3/282020
BULD9VG COVER CALCULATION
DRAWN
2
EME
4R(2020
CITY COMMENTS
JPR
CHECKED
DEIP
DATE
22820
USE (INCLUDING COPYING. DISTRIBUTION. AND/OR
CONVEYANCE OF INFORMATION) OF THIS PRODUCT O
STRICTLY PROHIBITED WITHOUT SATHRE-BERGOUIST, INC.'s
EXPRESS WRITTEN AUTHORIZATION. USE WITHOUT SAID
AUTHORIZATION CONSTITUTES AN ILLEGITIMATE USE AND
SHALL THEREBY INDEMNIFY SATHRE-BERGOUIST. INC. OF
ALL RESPONSIBILITY. SATHRE-BERGOUIST. INC. RESERVES
THE RIGHT TO HOLD ANY ILLEGITIMATE USER OR PARTY
LEGALLY RESPONSIBLE FOR DAMAGES OR LOSSES
RESULTING FROM ILLEGITIMATE USE.
I hereby certify that this survey, plan or report was prepared by me or trader my direct supervision and that I am a ddy Licensed
Laud Surveyor under the laws of the State of Minnesota.
Dated this 6th day of March, 2020.
Daniel L. Schmtdt, PLS Minnesota License No. 26147
scbmjdl@sathre.com
SATHRE-BERGQUIST, INC.
150 SOUTH BROADWAY WAYZATA, MN. 55391 (952) 476.6000
WVVW.SATHRECOM
T W P:027-RG E.023S EC.14
Dakota County
EAGAN,
MINNESOTA
CERTIFICATE OF SURVEY
PREPARED FOR:
NORTON HOMES
FILE NO.
64685-008
PERMIT
City of Eagan Permit Type:Plumbing
Permit Number:EA167475
Date Issued:03/17/2021
Permit Category:ePermit
Site Address: 3797 Lakeside Ct
Lot:2 Block: 1 Addition: Lakeside Of Eagan
PID:10-44305-01-020
Use:
Description:
Sub Type:Residential
Work Type:Replace
Description:Water Softener
Meter Size Meter Type Manufacturer Serial Number Remote Number Line Size
Comments:Carbon monoxide detectors are required within 10 feet of all sleeping room openings in residential homes (Minnesota State
Building Code).
Please call Building Inspections at (651) 675-5675 to schedule a final inspection.
Fee Summary:PL - Permit Fee (WS &/or WH)$59.00 0801.4087
Surcharge-Fixed $1.00 9001.2195
$60.00 Total:
I hereby acknowledge that I have read this application and state that the information is correct and agree to comply with all applicable State
of Minnesota Statutes and City of Eagan Ordinances.
Contractor:Owner:- Applicant -
Norton Homes Llc
18215 45th Ave Nw Ste D
Plymouth MN 55446
(612) 384-7309
Milbert Company (culligan)
1801 50th St E
Inver Grove Heights MN 55077
(651) 451-2241
Applicant/Permitee: Signature Issued By: Signature