1289 Deerwood Dr - Wilson Final Engeering Report
September 25, 2020
Libby Montreuil
Boulder Images Incorporated
14555 South Robert Street
Rosemount, MN 55068
RE: Final Report - Boulder Retaining Walls
Project Location: 1289 Deerwood Drive, Eagan, Minnesota
Project No. 19-427
Dear Ms. Montreuil:
This letter is being sent per your request regarding the recently completed boulder retaining walls at the
above listed property. This evaluation is based on: a site visit performed by me on July 2, 2020; a site visit
performed by me on September 24, 2020; verbal statement by you regarding construction means and
methods; and retaining wall design information prepared by me dated November 6, 2019.
Based on my site visits and the other information listed above, the retaining walls appear structurally
stable and in general conformance with the Retaining Wall Drawings as prepared, as well as boulder
retaining wall industry standards. Typical construction details such as use of drainage elements appear to
be followed correctly. As is normal for boulder retaining walls of this type, some seasonal and long-term
wall movement and backfill soil settlement should be expected. I recommend that concentrated areas of
surface water be directed away from the walls.
Scope of Service and Limitations
The purpose of this inspection and report is to evaluate the condition of the recently constructed or partially
constructed retaining wall. The report is not to be considered a guarantee of condition and no warranty is
implied. Our observations are non-destructive, and limited to those portions of the site/wall that could be
visually examined without excavation. Our scope of services did not include an exhaustive technical
investigation. No material sampling, analytic tests, precise measurements or engineering calculations were
performed. This includes but is not limited to: compaction testing, soil sampling, global stability calculations.
We did not determine whether the wall and its operation or use conform to any city codes, or regulations, or
restrictions that may be enforced within the jurisdiction. For construction phase services, it is understood that
the Contractor, not ENGINEER, is responsible for the construction of the project, and that ENGINEER is not
responsible for the acts or omissions of any contractor, subcontractor or material supplier; for safety
precautions, programs or enforcement; or for construction means, methods, techniques, sequences and
procedures employed by the Contractor. As Professional Engineers, it is our responsibility to evaluate
available evidence relevant to the purpose of this inspection. We are not, however, responsible for
conditions that could not be seen or were not within the scope of our service at the time of the inspection. If
additional documentation or information is made available for review, I reserve the right to amend or add to
the opinions and observations presented in this report.
See also, Terms and Conditions below.
This evaluation was performed using the design guidelines presented in the third edition of the “Design
Manual for Segmental Retaining Walls” (DMSRW) published by NCMA in 2009. If soil conditions,
proposed layouts, or other design parameters vary from that assumed, a revised analysis might be
1289 Deerwood Drive, Eagan, Minnesota
July 25, 2020
Page | 2
needed. If additional documentation or information is made available for review, I reserve the right to
amend or add to the opinions and observations presented in this report.
Please call me if you have any questions or need more information. Thank you.
Sincerely,
Paul Schimnowski, PE
MN PE# 40126
I hereby certify that this plan, specification, or report was prepared
by me or under my direct supervision and that I am a duly Licensed
Professional Engineer under the laws of the State of Minnesota.
Paul Schimnowski, P.E.
Date: September 25, 2020 License #: 40126 (MN)
1289 Deerwood Drive, Eagan, Minnesota
July 25, 2020
Page | 3
T E R M S A N D C O N D I T I O N S
This report is expressly made subject to the following terms and conditions to which all persons that receive and rely
thereon agree:
1. STANDARD OF SERVICE: Services performed by ENGINEER under this agreement shall be performed in a
manner consistent with the skill and care ordinarily used by members of the engineering profession practicing
under similar conditions at the time and in the locality the services are performed.
• Client recognizes that interpretations and recommendations of ENGINEER are based solely on the
information available to the company.
• ENGINEER will be responsible for those interpretations and recommendations, but shall not be responsible
for the interpretation by others of the information developed.
• Services provided reflect the professional judgment of ENGINEER, to the best of ENGINEER's knowledge,
information, and belief as of the date hereof.
• No other warranty or guarantee, express or implied, is made.
2. SCOPE OF SERVICE: Services performed by ENGINEER are expressly limited by the scope of services
ENGINEER has been employed by Client to perform.
3. TERMS OF PAYMENT: ENGINEER may require a retainer fee to be paid before commencing any project.
Extended engagements may require interim invoicing on a weekly, monthly, or other basis. At the completion of
the project, we will issue a final invoice. Payment of each invoice is due upon presentation. Failure to pay
invoices within the allotted time period will constitute a breach of contract and may result in suspension of work
until such time as all overdue payments are made in full. Should any suspension occur because of overdue
payments, the time for contract completion, if any is stated, shall be extended by the period of the suspension.
Invoiced balances remaining unpaid for thirty (30) days after the date of invoice may be charged a finance
charge in the amount of ½ percent per month from the date of invoice. If an invoice remains unpaid and it
becomes necessary, in the ENGINEERS’ opinion to initiate collection procedures, the client hereby agrees to
pay all collection costs including, but not limited to, reasonable fees for attorneys retained by ENGINEER and
court costs at our standard billing rate for time necessitated in court appearances or presentation of claim to the
appropriate court jurisdiction. Exceptions to payment terms must be specified in writing.
4. OWNERSHIP OF DOCUMENTS: All reports, field data, field notes, calculations, estimates and other documents
(‘reports’) prepared by Engineer, as instruments of service, shall remain the property of Engineer. Client agrees
that all reports furnished to Client or his agents, which are not paid for, will be returned upon demand and will not
be used by Client for any purpose whatever. ENGINEER will retain all pertinent records relating to the services
performed for a period of five years following submission of the report, during which period the records will be
made available to Client at all reasonable times.
5. COPIES OF DOCUMENTS: ENGINEER agrees to furnish client with an electronic copy of our report, drawings,
or documents relating to the services performed. Hard copies, bound or unbound, may be provided upon request
at charge of cost plus 10 percent, at ENGINEERS’s sole discretion. ENGINEER shall retain an electronic copy of
the final documents in its files for a period of five years.
6. INSURANCE: ENGINEER represents and warrants that it is protected by Workers Compensation insurance and
has such coverage under Public Liability and Property Damage insurance policies which ENGINEER deems
adequate. Certificate for all such policies of insurance shall be provided to the Client upon request in writing.
ENGINEER shall not be responsible for any loss, damage or liability arising from any acts by Client, its agents,
staff and other consultants employed by it.
7. TERMINATION: This agreement may be terminated by either party by written notice. In the event of termination,
ENGINEER shall be paid for services performed and expenses incurred up to the termination notice date.
Neither Client not ENGINEER may delegate, assign, sublet or transfer his/her duties or interest in this
Agreement without the written consent of the other party.
8. LIMITATION OF LIABILITY: To the fullest extent permitted by law, Client and ENGINEER
(a) waive against each other, and the other's employees, officers, directors, agents, insurers, partners, and
consultants, any and all claims for or entitlement to special, incidental, indirect, or consequential
damages arising out of, resulting from, or in any way related to this report,
(b) agree that ENGINEER’s total liability to Client shall be limited to the total amount of compensation
received by ENGINEER, and
(c) if an action is brought against the ENGINEER and the ENGINEER prevails, ENGINEER shall be
entitled to recover costs and expenses, including reasonable attorneys' fees and costs.
Location
1289 Deerwood Drive,
Eagan, MN
Photos Taken by:
Paul D Schimnowski
Inspection Date:
September 24, 2020
1 Tiered, completed boulder wall system. View
facing north.
2 Retaining walls and patio area at SE corner of
home.
3 Tiered walls in good structural condition. 4 Boulder wall tier in good condition.
5 Typical size boulders.6 Boulder wall at SE corner of home.
Location
1289 Deerwood Drive,
Eagan, MN
Photos Taken by:
Paul D Schimnowski
Inspection Date:
September 24, 2020
7 Stone stairs between tiers 8 Tiers and boulder outcroppings.
9 Approximately 7 feet exposed height.10 Typical boulder size.
11 Tiered walls with boulder outcroppings.12 Wall and patio at east side of home.